Blue Star Telepac Air Blue Star Telepac Air conditionersconditioners
SNAP SHOTS OF BSL TELEPACSNAP SHOTS OF BSL TELEPACRETURN AIR
SUPPLY AIR
EV APORATOR UNIT
CONDENSING UNIT
FeaturesFeaturesSpecially Designed for all ambient conditionsSpecially Designed for all ambient conditions
24 x 7 operation24 x 7 operation
High sensible applicationHigh sensible application
High fluctuating loadHigh fluctuating load
High EERHigh EER
Redundancy at failureRedundancy at failure
Higher CFMHigher CFM
Specifications
Model TP1- 302 YE TP1-362 YE TP3-362 RETP1-422 YE
TP3-482 SE TP3-482 RE
Capacity2.5 TR (1.25 x 2)
3.0 TR (1.5 TR x 2)
3.0 TR (1.5 x 2)
3.5 TR (1.75 x 2)
4.0 TR (2 x 2)
4.0 TR (2 x 2)
Airflow (CMH/Circuit) 1270 1525 1525 1780 2030 2030
Power Supply 230V/ 1 PH 230V/ 1 PH 415V/ 3 PH 230V/ 1 PH 415V/ 3 PH 415V/ 3 PH
Compressor Rotary Rotary Reciprocatory Rotary Scroll Reciprocatory
Control Micro Computer control
Sensible Cooling / Circuit
3375 Kcal/Hr 4050 Kcal/Hr 4050 Kcal/Hr4725 Kcal/Hr
5400 Kcal/Hr
5400 Kcal/Hr
Total cooling / Circuit 3750 Kcal/Hr 4500 Kcal/Hr 4500 Kcal/Hr5250 Kcal/Hr
6000 kcal/Hr 6000 kcal/Hr
Note:
Compressor- Y Rotary/ R- Recip / S-Scroll
E-Economy/TP1-Single Phase/ TP3-Three phase
Unit Dimensions
Indoor Unit Outdoor Unit Total Unit
Width (mm) 665 665 665
Dept (mm) 743 611 743
Height (mm) 939 1064 2111
Micro Controller FeaturesMicro Controller Features• Fully programmableFully programmable• Complete protection for AC from unhealthy conditionsComplete protection for AC from unhealthy conditions• All set points programmable from keypadAll set points programmable from keypad• Password protection for controllerPassword protection for controller• Simple 4 key keypad for onsite programmingSimple 4 key keypad for onsite programming• 16 Character 2 line back lit LCD display on controller front panel16 Character 2 line back lit LCD display on controller front panel• Separate alarm contacts for AC 1/ AC2 fail alarm,powerfailSeparate alarm contacts for AC 1/ AC2 fail alarm,powerfail• Automatic display of AC parameters one by one in Run modeAutomatic display of AC parameters one by one in Run mode• Status & healthy indication by LEDs on front panelStatus & healthy indication by LEDs on front panel• Alarm indication by LEDs on front panelAlarm indication by LEDs on front panel• Room temperature sensing by precise sensorRoom temperature sensing by precise sensor• Separate outputs for each fan and compressorSeparate outputs for each fan and compressor• Direct display of line voltage and actual current drawn by Direct display of line voltage and actual current drawn by
compressorcompressor• Direct display of actual room temperatureDirect display of actual room temperature• Sequencing of compressors for equal run hours, site selectableSequencing of compressors for equal run hours, site selectable• Fault log history( last 5 faults)Fault log history( last 5 faults)• Smoke fire & D.G.sensingSmoke fire & D.G.sensing• Automatic timer mode operation if room sensor failsAutomatic timer mode operation if room sensor fails