TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek...

134
TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North 60 th Street Scottsdale, Arizona 85266 Prepared by: Dominion Environmental Consultants, Inc. 20045 North 19 th Avenue, Building 7 Phoenix, Arizona 85027 Dominion Project No. AZ0734.34 September 20, 2018

Transcript of TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek...

Page 1: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

TECHNICAL SPECIFICATIONSASBESTOS ABATEMENT

forCave Creek Unified School District

SITE LOCATIONBlack Mountain Elementary School

33606 North 60th StreetScottsdale, Arizona 85266

Prepared by:

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7

Phoenix, Arizona 85027

Dominion Project No. AZ0734.34

September 20, 2018

Page 2: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

TECHNICAL SPECIFICATION FOR ASBESTOS ABATEMENTBLACK MOUNTAIN ELEMENTARY SCHOOLROOFS - BUILDINGS 100, 200, 300, 400 & 500

Cave Creek Unified School District (CCUSD) has contracted with Dominion Environmental Consultants, Inc.(Dominion), to provide a general Technical Specification (Specifications) for the Asbestos AbatementOversight, Ambient Air Monitoring, Clearance Air Monitoring and Close-Out Documentation for the asbestosabatement project to take place on the roofs of Buildings 100, 200, 300, 400 and 500 at Black MountainElementary School in Scottsdale, AZ.

The following Specifications are written with the intention that a Dominion representative will continuallymonitor the entire abatement process for the asbestos-containing materials (ACM). Specificationmodifications are subject to preliminary approval by a representative of Dominion and final approval byCCUSD. Only under the direction and approval of CCUSD, Dominion will have the ability to stop jobactivities that, in their judgement, are not being performed satisfactorily, or in accordance with applicableasbestos regulations or the requirements of these Specifications. Such a work stoppage shall not result in anycosts to CCUSD or Dominion, nor will it relieve the Asbestos Abatement Contractor (Contractor) from anyliability for the violation of these regulations, contractual agreements or the requirements of theseSpecifications.

The designated Abatement Contractor (Contractor) shall be responsible for his own work and properprotection of his workers along with the proper removal and proper disposal of any abated ACM from theCCUSD, Black Mountain Elementary School - Buildings 100, 200, 300, 400 and 500 which are scheduledfor future renovation. The currently identified ACM are outlined in the CCUSD Asbestos Survey dated May16, 17, 22, 2018 (see Attachment A - Black Mountain Elementary School Roof Asbestos Survey). A summaryof the ACM (>1% Asbestos Content) and Unclassified Asbestos Materials (<1% Asbestos Content) identifiedto date are as follows:

*ACM

• White Coated Asphalt Roll On Cross Section - Building 100• Silver Seam Mastic - Building 100• Metal Roof Seam Caulking - Building 100• Metal Roof Seam Caulking - Building 200• Gray Flashing Patch Mastic - Building 200• Metal Roof Seam Caulking - Building 300• White Vent Caulking (& Tan Vent Caulking)- Building 300• Gray Vent Caulking - Building 300• Metal Roof Seam Caulking - Building 500

*UNCLASIFIED ASBESTOS MATERIALS

• Silver Paint/Black Penetration Mastic - Building 300• White Vent Caulking - Building 400• Metal Roof Seam Caulking - Building 400

*Note: See Attachment B, for ACM location maps and asbestos abatement details.

Page -1-

Page 3: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

CCUSD, through Dominion, shall have the authority to request that Contractor personnel (i.e., supervisors,foremen, or workers) be removed from the site and replaced if, in their judgement, those individuals’activities are not satisfactory, safe, or in accordance with applicable regulatory or other asbestos relatedguidelines and the requirements of these Specifications.

The work schedule will be regular work days Monday-Friday with no overtime, unless otherwise mandatedand approved in writing by CCUSD.

At a minimum, the selected Contractor shall utilize proper engineering controls to protect the properlycertified and experienced workers along with the occupants in and around the surrounding areas fromexposure to any on-site contaminates as it relates to the roofing abatement activities, as outlined below:

Regulatory Compliance:

The abatement contractor shall comply with all applicable Federal, State and Local Regulatory Guidelinesincluding but not limited to the following:

• OSHA 29 CFR 1926.1101 - Construction Industry • OSHA 29 CFR 1910.20 - Access to Employee Exposure and Medical Records• OSHA 29 CFR 1910.1200 - Hazard Communication • OSHA 29 CFR 1910.134 - Respirator Protection • EPA 40 CFR 61 - NESHAP Renovation and Demolition Standard• Maricopa County Rule 370 - Hazardous Air Pollutant Program• U.S. Department of Transportation 49 CFR 171 and 172 - Hazardous Substances

As stated the Contractor shall assume full responsibility and liability for compliance with all applicableFederal, State, and Local Regulations pertaining to work practices, hauling, disposal, and protection ofworkers, visitors to the site, and persons occupying areas adjacent to the site.

Contractor Qualifications:

• The Contractor shall be a pre-approved “State of Arizona” Abatement Contractor and shall providea current State of Arizona Contract number.

• The Contractor shall have a current valid Contractors License applicable to asbestos abatementactivities.

• The Contractor shall have current A+ rated or better, Occurrence-Based Liability Insurance withcoverage limits of $1,000,000 per Occurrence and $1,000,000 in Aggregate or as otherwise requiredby CCUSD.

• The Contractor’s asbestos workers and supervisors shall all possess either a current AHERA workercertification, or a supervisor’s certification from an approved EPA training facility. The workers orsupervisors shall also have a valid color photo identification from an EPA approved training facilityor a government issued photo identification card. All shall be kept on-site at all times.

• The Contractor’s workers and supervisors shall have current pulmonary medical examinations andfit tests for all employees required to use negative pressure respirators as required by OSHA. All shallbe kept on-site at all times.

Page -2-

Page 4: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Contractors Pre-Job Submittals:

The selected Contractor shall provide to CCUSD’s representative (Dominion) proof of the previouslyreferenced qualifications within twenty-four (24) hours prior to the commencement of the abatementactivities. In addition, the contractor will also be required to provide the following information prior to thecommencement of the abatement activities:

• Any historical data for the work being performed. In the event no historical data is available, anInitial Exposure Assessment will be provided and shall be followed by a Negative ExposureAssessment, as air sample results become available.

• A copy of the NESHAP notification (if necessary) shall be provided to the project oversightconsultant and CCUSD for review.

• The Contractor shall provide to CCUSD an abatement schedule to include preparation of regulatedwork areas, abatement, final cleaning and completion of the abatement activities.

• The Contractor shall submit Safety Data Sheets (SDS) for any materials proposed to be brought on-site, for approval by CCUSD and Dominion.

• The Contractor shall submit proof of insurance acceptable to the CCUSD, for approval.

Minimum Contractor Responsibilities & Requirements:

• Conditions affecting the work, including but not limited to, the physical conditions of the site,availability of water and utilities, accessibility, storage and handling of equipment and materials, orother factors that may affect the performance of abatement activities.

• The Contractor shall ensure that all asbestos work is performed within regulated work areas and issupervised by a competent person.

• The Contractor shall use hand methods, unless the Contractor deems mechanical removal will savetime and money. It is important to note that the time schedule is of the utmost importance. If theContractor elects to introduce mechanical means then the Contractor will need to file a NESHAPNotification and pay all applicable fees with the County.

• The verification of the location(s) and quantities of ACMs and Unclassified Asbestos Materials, aswell as the location and quantities of other surface and subsurface materials or obstacles that may beencountered are the full responsibility of the Contractor to verify prior to project start.

• The Contractor shall also consider any specific requirements or work procedures developed byCCUSD or Dominion and include provisions as necessary for compliance. Any failure by theContractor to acquaint himself with available information does not relieve the Contractor from theresponsibility of properly estimating the cost and degree of difficulty of successfully performing theabatement work. Information regarding material type, location, or quantity that is made available byCCUSD or its Consultant(s) is informational only. Neither CCUSD nor its Consultant(s) isresponsible for any conclusions or interpretations made by the Contractor on the basis of thisinformation. Any concerns, questions or clarifications should be addressed by the Contractor priorto project start.

Page -3-

Page 5: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

• Once abatement activities have commenced, all workers or supervisors in the regulated work area shall at a minimum have a half-face HEPA filtered respirator. It is the Contractors full and totalresponsibility to ensure that their employees have the proper Personal Protective Equipment (PPE).

• The Contractor shall furnish all labor, materials, services and equipment necessary for the abatementof all ACM in the designated areas.

• All vacuums utilized by the Contractor shall be HEPA filtered.

• The Contractor shall provide a Manometer for all Negative Pressure Enclosures (NPE) in order tomaintain a pressure of -0.02 column inches of water pressure differential (If Needed).

• The Contractor shall furnish the site with power and water that is needed to support the abatementactivities, as well as supply the Consultant with any power that is needed to run ambient or clearanceair samples.

• The Contractor shall provide hygiene facilities (i.e.. J Johns, wash stations, etc.) in accordance withthe regulatory guidelines.

• If removing Regulated Asbestos-Containing Materials (RACM) as defined by the EPA, amendedwater shall always be used to adequately wet the RACM.

• When removing Category I and II ACMs, wet removal methods shall be utilized.

• The Contractor shall post all notices, notifications, permits and proper proof of training required bythe applicable Federal, State, and Local Regulations, and maintain one (1) copy of the applicableasbestos survey on-site at all times.

• The Contractor shall regularly inspect regulated work areas during abatement to ensure that allapplicable regulations and work procedures are being followed at all times. The Contractor shallinspect the regulated work areas prior to the completion of abatement to ensure all visible debris andcontaminated materials have been cleaned and/or removed.

• The Contractor will be responsible for site security of the work areas 24/7 until completion and finalclearance has been given.

• All routine communications, change requests to scope/schedule and procedures shall be submittedto the Consultant for initial consideration and final approval by CCUSD.

• The Contractor shall continually coordinate with the General Contractor on a daily basis for dryingin any abated areas. The Contractor shall not abate any more than what the General Contractor candry in on a daily basis. Any ACM removed without having written arrangements with GeneralContractor, is at the Contractor’s own risk and the Contractor will therefore be held financiallyresponsible for any related water damages.

• Work and services not part of the established scope shall not be initiated without prior scope and costapproval by CCUSD. Work and services undertaken by the Contractor without prior approval ofCCUSD shall be done at the risk and expense of the Contractor. Any labor or materials necessary toreverse unauthorized work shall be provided at no charge by the Contractor and without change tothe schedule.

Page -4-

Page 6: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Minimum Work Area Requirements:

• For all Class II work performed outside of the building, the Contractor shall:

Regulate the work area by constructing appropriate barriers in order to limit accessby unauthorized personnel and install appropriate signage.

Utilize impermeable drop cloths or coverings in all areas that have the potential ofbecoming contaminated due to abatement activities (i.e. soil, sidewalks, and othersurfaces), to protect those areas from contamination.

Promptly clean-up and containerize all generated asbestos-containing waste in leak-tight containers and carefully lower the containers to the ground, not dropping,throwing, sliding, or otherwise damaging or disturbing the material or the wrappingthat contains it. The Contractor shall not use chutes to transport ACM from anelevated surface to the ground.

• Provide an area of sufficient size as to accommodate cleaning of equipmentand removal of personal protective equipment without spreadingcontamination beyond the work area.

• At the end of the day’s work or before removing respirator protection, at aminimum each worker shall perform the following decontaminationprocedures:

HEPA vacuum hands, hair, face, and respirator, giving special attention tothe respirator seal area on the face.

Remove the respirator, and HEPA vacuum face at the respirator seal and allsurfaces of the respirator. HEPA vacuum any parts of hair or head coveredby the respirator’s straps.

Wet clean the respirator in accordance with manufacturer’s instructions,taking care to protect battery packs and moving parts, if any.

Thoroughly wash face and hands with soap and water.

Lock-out and tag-out all power supplies to the work area and provide power froma source outside the work area that is ground fault protected.

Note: Prior to the commencement of any abatement activities, Dominion’s field supervisor willconduct a complimentary work area inspection of the regulated work area.

Ambient Air Monitoring:

• Pursuant to the requirements of OSHA Regulation 29 CFR 1926.1101, the Contractor shall monitorairborne fiber counts and worker exposure levels inside the regulated area throughout the asbestosabatement and cleaning operations.

• Copies of all air monitoring records and sample results collected by the Contractor shall be providedto Dominion within 24 hours of collection, for review.

Page -5-

Page 7: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

• The method of air monitoring and analysis by the Contractor during abatement operations shall beconducted in accordance with OSHA Regulations 29 CFR 1926.1101, using the NIOSH 7400 methodfor Phase Contrast Microscopy (PCM).

• The laboratory used to analyze asbestos samples shall be a participant in the AIHA/NIOSH PATprogram for asbestos fiber counting and accredited by the National Voluntary LaboratoryAccreditation Program (NVLAP) for asbestos analysis by PCM.

• Personal air monitoring of Contractor Personnel is for purposes of the Contractor. It shall beperformed by the Contractor at no additional cost to CCUSD.

• Throughout the asbestos abatement and cleaning operations, area air monitoring shall be conductedby the CCUSD representative (Dominion) both inside and outside the work areas. The airborne fiberlevel outside the work area shall not exceed 0.01 fibers per cubic centimeter of air (0.01 f/cc). Theairborne fiber level inside the work area shall not exceed 0.10 f/cc over an eight hour TWA or 1.0f/cc over a 30 minute period. If any of these levels are exceeded, removal activities will stop until theair levels have been reduced and the abatement procedures have been modified. Time lost due toexcessive air concentrations is the responsibility of the Contractor. Time delays will not be grantedfor reducing fibers levels in the work areas.

• The laboratory used by Dominion to analyze asbestos samples shall be a participant in theAIHA/NIOSH PAT program for asbestos fiber counting and accredited by the National VoluntaryLaboratory Accreditation Program (NVLAP) for asbestos analysis by PCM and PLM.

• All air samples collected by the Contractor or Dominion shall be analyzed within 24 hours ofcollection.

• “Airborne Fibers” in these provisions, include all fibers regardless of composition as counted byPCM, unless additional analysis by Transmission Electron Microscopy (TEM) demonstrates to thesatisfaction of Dominion, that non-asbestos fibers are being counted.

Waste Disposal:

• Asbestos-containing and/or contaminated materials shall be provided with proper disposal at alandfill operated in accordance with the requirements of NESHAP Asbestos Regulations (40 CFRPart 61, Subpart M), and approved by EPA for asbestos wastes.

• All wastes are to be hauled by a waste hauler with all required licenses from all State and localauthorities with jurisdiction.

• All containerized waste shall be carefully loaded into fully enclosed dumpsters, trucks, or otherappropriate vehicles for transport. Care must be exercised before and during transport to ensure thatno unauthorized person(s) have access to the material. The interior of the transport vehicle shouldbe protected with two (2) layers of polyethylene plastic sheeting, each layer 6-mil thick.

• All asbestos waste shall be at a minium doubled bagged or “buritto wrapped” with two (2) layers of6-mil thick re-enforced polyethylene plastic sheeting, adequately wet, proper warning labels andgenerator labels.

• Containerized waste materials must NOT be stored outside of the work area. Take containers fromthe work area directly to a sealed truck or dumpster.

Page -6-

Page 8: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

• Do NOT transport bagged materials on open trucks. Transport only properly sealed containersmarked with the OSHA and DOT labels in closed-bed vehicles protected with sheet plastic.

• At the disposal site, carefully unload containerized asbestos waste from the transport vehicle.Wrapped asbestos waste may require special unloading procedures and equipment. The Contractorshall ensure that all special procedures are followed, and special equipment is provided as needed.

• Retain landfill receipts and waste manifests as proof of proper disposal. Copies of all of thesedocuments shall be provided to the Owner’s Representative upon completion of the work.

• The Contractor is responsible for obtaining all required signatures on landfill disposal documents andwaste manifests. Arrangements for obtaining the Owner’s signature on these types of documents mustbe made by the Contractor sufficiently prior to scheduled transportation of the asbestos waste toensure that no delay in transporting or disposal of the waste will occur.

Clearance Sampling:

• Because the abatement is being performed outside, a visual inspection of the abated areas will beperformed by CCUSD’s representative (Dominion). No final clearance air sampling will be required.

Contractor’s Post Job Submittals:

A complete and detailed copy of all of the Contractor’s post project documentation shall be submitted toCCUSD’s representative before the project will be considered for completion and release of the Contractor’sfinal payment. This will include but not be limited to the following:

• Copy of the Certificate of Insurance

• NESHAP Notification (If Required)

• Daily Field Reports

• Daily Sign-in Sheet

• Daily Regulated Work Area Log

• Air Sample Laboratory Reports

• Laboratory Certifications

• Historical Data/Negative Exposure Assessments

• Workers and Supervisors AHERA Certification, Medicals and Respirator Fit Test

• Signed Waste Manifest

Page -7-

Page 9: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

ATTACHMENT A

Black Mountain Elementary SchoolRoof Asbestos Survey Report

Dominion Project # AZ0734.31Dated: May 2018

Page -8-

Page 10: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Prepared for:

Cave Creek Unified School District #93P. O. Box 426

Cave Creek, Arizona 85327

LIMITED ASBESTOSSURVEY REPORT

FOR

BLACK MOUNTAIN ELEMENTARY SCHOOLROOF INSPECTION

BUILDINGS 100, 200, 300, 400, 50033606 NORTH 60TH STREET

SCOTTSDALE, ARIZONA 85266

Prepared by:

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7

Phoenix, Arizona 85027

Dominion Project No. 0734.31

Inspection Dates: May 16, 17, 22, 2018

Page 11: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

TABLE OF CONTENTS

LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1

EXECUTIVE SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2

SITE PLANS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3

PLM BULK SAMPLE SUMMARIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4

PLM BULK SAMPLE LOCATION MAPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5

PLM LABORATORY ANALYSIS REPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6

ACM LOCATION MAPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 7

OSHA <1% UNCLASSIFIED MATERIAL LOCATION MAPS . . . . . . . . . . . . . SECTION 8

EPA NESHAP NOTIFICATION INFORMATION SHEET . . . . . . . . . . . . . . . . . SECTION 9

GENERAL NOTES/EXCLUSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 10

INSPECTOR CERTIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 11

LABORATORY CERTIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 12

Page 12: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 1

Ë

LIMITATIONS

Page 13: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

LIMITATIONS

The conclusions and results contained herein are based solely on the information presented in thisreport. The limited sampling, testing, and observations described in the report represent conditionsonly at the specified times and locations. Additional materials or information which were hidden,undiscovered, inaccessible, or not a part of the findings presented herein, would result in themodification of the conclusions and recommendations made herein. Any response action guidelinesare based solely on the findings contained herein. The response action guidelines are presented asa courtesy and are not to be considered a complete or detailed set of specifications. Dominionperformed this survey as directed by the client and in compliance with applicable regulations.

Please note, with regard to laboratory analysis of suspect bulk asbestos-containing materials: TheEnvironmental Protection Agency (EPA) Method 600/R-93-116, Polarized Light Microscopy (PLM)is used for the testing of bulk building materials for asbestos by performing a visual estimation. Thismethod is the most widely used method for estimating asbestos in bulk building materials and workswell for most sample types. However, it might require a more detailed method such as pointcounting for accurate estimation of asbestos in samples with low asbestos concentration. Thismethod is also not applicable for samples containing large amounts of fine fibers below theresolution of the PLM (<0.3 microns). Typically, the asbestos fibers present in non-friableorganically bound (NOB) materials are often less than 0.1 microns in diameter and therefore maycause the PLM method to yield low estimates or even false negative results.

Dominion suggests that Transmission Electron Microscopy (TEM) Chatfield Semi-Quantitative EPAMethod 600/R-93-116 be used to confirm all negative results of NOB materials. This method isparticularly useful to reduce the possibility of false negatives in NOBs and to provide additionalquantitative data for samples which contain low levels of asbestos. The TEM method is availableat additional cost and is done only at the client’s request.

Dominion’s scope of service did not include the inspection for, or identification of, fungi, PCB’s,lead paint or any other hazardous or controlled substance not specifically identified herein.

Dominion is not responsible for the accuracy of information or any services provided by others, orfor conditions or consequences arising from relevant facts that were withheld, concealed,undiscovered, or not fully disclosed. Dominion is not a law firm and therefore, makes norepresentations regarding any potential liability of any person or entity for site conditions. Further,Dominion is not qualified to present medical advice. If any present or future health issues are inquestion, it is recommended that the findings in this report be presented to a qualified medicalprofessional for evaluation.

Page 14: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 2

Ë

EXECUTIVE SUMMARY

Page 15: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EXECUTIVE SUMMARY

INTRODUCTION

This report presents the results of a limited asbestos inspection of the roofs of Buildings 100, 200,300, 400 and 500, on the Black Mountain Elementary School campus located at 33606 North 60th

Street, Scottsdale, Arizona. Pursuant to the information provided by the Cave Creek Unified SchoolDistrict #93 (CCUSD), the roofs of Buildings 100, 200, 300, 400 and 500 are scheduled forrenovation. Dominion was instructed to perform a limited asbestos inspection of the roofs ofBuildings 100, 200, 300, 400 and 500 scheduled for replacement in accordance with AHERA,OSHA, and NESHAP guidelines. Dominion was authorized to perform the asbestos inspection byverbal authorization from Mr. Mike Santina on May 11, 2018.

ASBESTOS SAMPLING

The limited asbestos inspection of Buildings 100, 200, 300, 400 and 500, was conducted on May16, 17 and May 22, 2018, by Mr. Basilio Marcos, an EPA-accredited AHERA Asbestos BuildingInspector.

A total of one hundred eight (108) bulk samples were collected from forty-three (43) homogeneousbuilding materials throughout Buildings 100, 200, 300, 400 and 500. The suspect bulk samples weresubmitted to EMLab P&K (EMLab) for analysis using Polarized Light Microscopy (PLM) methods.EMLab used the methods prescribed in Method 40 CFR, Part 763, in the Code of Federal Registerin analyzing bulk samples. EMLab is certified by the National Institute of Standards and Technologyas a National Voluntary Laboratory Accreditation Program (NVLAP), Number 500031-0. Thesuspect asbestos bulk samples were collected and submitted to the laboratory using establishedchain-of-custody procedures. Bulk samples were collected utilizing safety and health practices asrequired by the Occupational Safety and Health Administration (OSHA).

Identified in the following list, separated by building, are the forty-three (43) suspect homogeneousmaterials that were sampled during Dominion’s asbestos inspections.

Building 100

• Black Felt Under Metal Roof• Tan Flashing Caulking• White Coated Asphalt Roll-On Cross Section (Coating, Shingle, Tar, Felt)• White Roll-on Cross Section (Coating, Shingle, Tar, Foam, Roofing Material)• Foam Coating Around A/C - Yellow Foam• Foam Coating Around A/C - White Coating

Page -1-

Page 16: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

• Silver Seam Mastic• White Penetration Mastic• Black Mastic for White Penetration Mastic• White Flashing Caulking• Metal Roof Hood Caulking• Metal Roof Seam Caulking

Building 200

• Black Felt Under Metal Roof• Metal Roof Seam Caulking• White Roll-On Cross Section (Roofing Material Membrane, Tar, Felt)• White Penetration Mastic• White Vent Caulking• Gray Flashing Patch Mastic

Building 300

• Black Felt Under Metal Roof• Metal Roof Seam Caulking• White Roll-On Roof Cross Section

(Roofing Material Membrane, Coating, Tape, Mastic, Shingle, Tar, Felt)• Penetration Mastic - White• Silver Paint for Penetration Mastic• Black Roofing Mastic for Penetration Mastic• Green Coating for Penetration Mastic• White Vent Caulking• Tan Vent Caulking• Gray Vent Caulking

Building 400

• Black Felt Under Metal Roof• Metal Roof Seam Caulking• White Roll-On Roof Cross Section (Roofing Material, Shingle, Tar, Felt)• Penetration Mastic - White• Black Mastic for Penetration Mastic• Penetration Mastic - Light Green• White Vent Caulking• Gray Vent Caulking

Page -2-

Page 17: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Building 500

• Black Felt Under Metal Roof• Metal Roof Seam Caulking• White Roll-On Roof Cross Section (Roofing Material, Shingle, Tar, Felt)• Penetration Mastic - White• Green Mastic for Penetration Mastic• Black Mastic for Penetration Mastic• Parapet Wall Beam Caulking

Thirty (30) of the homogeneous materials sampled, were reported by the laboratory using the PLManalysis method, to be “none detected” for asbestos content.

As seen in Table 1, nine (9) of the homogenous materials sampled, were reported by the laboratoryusing the PLM analysis method, to contain greater than one percent (>1%) asbestos-content.

Table 1 - Materials Containing >1% Asbestos by PLM Analysis

ACM LocationNESHAPCategory

OSHA RemovalClassification

EstimatedQuantity

PLM Results

White Coated AsphaltRoll-On C/S

(Brown Roofing Felt)

Roof-Bldg. 100

Cat. I Class IIAmount

Undeterminedat this time

20%-35% Chrysotile

Silver Seam MasticRoof-

Bldg. 100Cat. II Class II 100 sq. ft. 5% Chrysotile

Metal Roof SeamCaulking

Roof-Bldg. 100

Cat. II Class IIAmount

Undeterminedat this time

5% Chrysotile

Gray Flashing PatchMastic

Roof-Bldg. 200

Cat. I Class II 10 sq. ft. 10% Chrysotile

Metal Roof SeamCaulking

Roof-Bldg. 200

Cat. II Class IIAmount

Undeterminedat this time

2% Chrysotile

Metal Roof SeamCaulking

Roof-Bldg. 300

Cat. II Class IIAmount

Undeterminedat this time

2% Chrysotile

White Vent CaulkingRoof-

Bldg. 300Cat. II Class II 20 sq. ft. 4% Chrysotile

Gray Vent CaulkingRoof-

Bldg. 300Cat. II Class II 20 sq. ft. 5% Chrysotile

Metal Roof SeamCaulking

Roof-Bldg. 500

Cat. II Class IIAmount

Undeterminedat this time

3% Chrysotile

Page -3-

Page 18: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

As seen in Table 2, four (4) homogeneous materials sampled were reported by the PLM analysismethod, to contain less than on percent (<1%) asbestos-content. The sampling protocol outlined bythe EPA is to analyze bulk samples by the PLM method.

Table 2 - Materials Containing <1% Asbestos by PLM Analysis

Material LocationNESHAPCategory

OSHA RemovalClassification

EstimatedQuantity

LaboratoryResults

Silver Paint/BlackMastic on

Penetration Mastic

Roof-Bldg. 300

N/A Unclassified 20 sq. ft. <1% Chrysotile (PLM)

Metal RoofSeam Caulking

Roof-Bldg. 400

N/A UnclassifiedAmount

Undeterminedat this time

<1% Chrysotile (PLM)

White VentCaulking

Roof-Bldg. 400

N/A Unclassified 30 sq. ft. <1% Chrysotile (PLM)

RECOMMENDATIONS

Based on the previously referenced sampling data, Dominion recommends that the above listedACM identified by laboratory analysis to contain greater than one percent (>1%) asbestos-content,be properly abated by a qualified asbestos abatement contractor. The contractor should comply withall governing regulatory agencies guidelines. If any un-sampled suspect building materials arediscovered during the demolition activities, those building materials should be properly sampled bya certified inspector prior to their disturbance.

The EPA does not regulate materials reported to contain less than one percent (<1%) asbestos,however OSHA regulates all materials that contain asbestos regardless of the amount of asbestosin the material. Therefore, based on the prior stated analytical results, Dominion also recommendsthat OSHA unclassified work practices be followed for any building materials containing less thanone percent (<1%) asbestos-content that will be affected during the roof replacement activities.

All documentation is provided to CCUSD and should be retained in a permanent record. Should youhave any questions regarding the procedures that were followed during this project, please contactDominion at any time. Thank you for the opportunity to provide these environmental consultingservices.

Basilio MarcosAHERA Asbestos Building InspectorAHERA Certificate No. G 7264Expires: July 7, 2018

Page -4-

Page 19: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 3

Ë

SITE PLANS

Page 20: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 100

Roof

Site Plan (1 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Page 21: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 200

Roof

Site Plan (2 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Building 200

Page 22: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 300

Roof

Site Plan (3 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Building 300

Page 23: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 400

Roof

Site Plan (4 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Building 400

Page 24: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 500

Roof

Site Plan (5 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Building 500

Page 25: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 4

Ë

PLM BULKSAMPLE SUMMARIES

Page 26: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 100 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content0734.31-PLM-1 Black Felt Under Metal Roof South No None Detected0734.31-PLM-2 Black Felt Under Metal Roof West of Center No None Detected0734.31-PLM-3 Black Felt Under Metal Roof North No None Detected0734.31-PLM-4 Tan Flashing Caulking South No None Detected0734.31-PLM-5 Tan Flashing Caulking South No None Detected0734.31-PLM-6 Tan Flashing Caulking South No None Detected

White Coated Asphalt Roll-On C/S - Coating No None DetectedBlack Roofing Shingle w/Multi-Colored Pebbles No None Detected

Black Roofing Tar No None DetectedBrown Roofing Felt No 35% Chrysotile

Black Roofing Tar No None DetectedBlack Roofing Shingle w/White Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None Detected

White Coated Asphalt Roll-On C/S - Coating No None DetectedBlack Roofing Shingle w/Multi-Colored Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar No None DetectedBrown Roofing Felt No 35% Chrysotile

Black Roofing Tar No None DetectedBrown Roofing Felt No 20% Chrysotile

Black Roofing Tar No None DetectedBrown Roofing Felt No 35% Chrysotile

Black Roofing Tar No None Detected

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 100Sample Date: May 16, 2018

Dominion Project Number: 0734.31

0734.31-PLM-7 South

0734.31-PLM-8 Southwest of Center

Page 27: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 100 - Page 2

Sample Number Material Description Sample Location Friable Asbestos Content

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 100Sample Date: May 16, 2018

Dominion Project Number: 0734.31

White Coated Asphalt Roll-On C/S - Coating No None DetectedBlack Roofing Shingle w/Multi-Colored Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar No None DetectedBrown Roofing Felt No 35% Chrysotile

Black Roofing Tar No None DetectedBrown Roofing Felt No 20% Chrysotile

Black Roofing Tar No None DetectedBrown Roofing Felt No 35% Chrysotile

Black Roofing Tar No None DetectedWhite Roll-on C/S - Coating No None Detected

Black Roofing Shingle w/Multi-Colored Pebbles No None DetectedBlack Roofing Tar No None Detected

Yellow Foam No None DetectedGray Non-Fibrous Material No None Detected

White Roll-on C/S - Coating No None DetectedBlack Roofing Shingle w/Multi-Colored Pebbles No None Detected

Black Roofing Tar No None DetectedYellow Foam No None Detected

Gray Non-Fibrous Material No None DetectedWhite Roll-on C/S - Coating No None Detected

Black Roofing Shingle w/Multi-Colored Pebbles No None DetectedBlack Roofing Tar No None Detected

Yellow Foam No None DetectedGray Non-Fibrous Material No None Detected

0734.31-PLM-9 Southwest of Center

0734.31-PLM-10 West of Center

0734.31-PLM-11 Center

0734.31-PLM-12 Center

Page 28: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 100 - Page 3

Sample Number Material Description Sample Location Friable Asbestos Content

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 100Sample Date: May 16, 2018

Dominion Project Number: 0734.31

Foam Coating Around A/C - Yellow Foam No None DetectedWhite Coating No None Detected

Foam Coating Around A/C - Yellow Foam No None DetectedWhite Coating No None Detected

Foam Coating Around A/C - Yellow Foam No None DetectedWhite Coating No None Detected

0734.31-PLM-16 Silver Seam Mastic AC Pad - South No 5% Chrysotile0734.31-PLM-17 Silver Seam Mastic Southwest No 5% Chrysotile0734.31-PLM-18 Silver Seam Mastic Southwest No 5% Chrysotile

White Penetration Mastic No None DetectedBlack Mastic No None Detected

White Penetration Mastic No None DetectedBlack Mastic No None Detected

White Penetration Mastic No None DetectedBlack Mastic No None Detected

White Penetration Mastic No None DetectedBlack Mastic No None Detected

White Penetration Mastic No None DetectedBlack Mastic No None Detected

White Penetration Mastic No None DetectedBlack Mastic No None Detected

0734.31-PLM-25 White Flashing Caulking Northeast of Center No None Detected0734.31-PLM-26 White Flashing Caulking Northeast of Center No None Detected0734.31-PLM-27 White Flashing Caulking Northeast of Center No None Detected0734.31-PLM-28 Metal Roof Hood Caulking Center No None Detected0734.31-PLM-29 Metal Roof Hood Caulking Center No None Detected0734.31-PLM-30 Metal Roof Hood Caulking Center No None Detected0734.31-PLM-31 Metal Roof Seam Caulking Southwest No 5% Chrysotile0734.31-PLM-32 Metal Roof Seam Caulking West No 5% Chrysotile0734.31-PLM-33 Metal Roof Seam Caulking West of Center No 5% Chrysotile

0734.31-PLM-19

0734.31-PLM-20

0734.31-PLM-21

Southwest Corner

South

Southwest of Center

0734.31-PLM-13

0734.31-PLM-14

0734.31-PLM-15

Center

Southwest of Center

AC Pad - South

0734.31-PLM-22 West of Center

0734.31-PLM-23 North of Center

0734.31-PLM-24 Northeast of Center

Page 29: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 200 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content0734.31-PLM-1 Black Felt Under Metal Roof South No None Detected0734.31-PLM-2 Black Felt Under Metal Roof Center No None Detected0734.31-PLM-3 Black Felt Under Metal Roof Northeast No None Detected0734.31-PLM-4 Metal Roof Seam Caulking South No 2% Chrysotile0734.31-PLM-5 Metal Roof Seam Caulking Center No 2% Chrysotile0734.31-PLM-6 Metal Roof Seam Caulking Northeast No 2% Chrysotile

White Roll-On C/S - White Roofing Material Membrane No None DetectedBlack Roofing Tar & Felt & Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None Detected

White Roll-On C/S - White Roofing Material Membrane No None DetectedBlack Roofing Tar & Felt & Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None Detected

White Roll-On C/S - White Roofing Material Membrane No None DetectedBlack Roofing Tar & Felt & Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None Detected

0734.31-PLM-10 White Penetration Mastic AC Pad - East No None Detected0734.31-PLM-11 White Penetration Mastic AC Pad - Northeast No None Detected0734.31-PLM-12 White Penetration Mastic AC Pad - Southeast No None Detected0734.31-PLM-13 White Vent Caulking Southeast No None Detected0734.31-PLM-14 White Vent Caulking Northwest No None Detected0734.31-PLM-15 White Vent Caulking Northwest No None Detected0734.31-PLM-16 Gray Flashing Patch Mastic Southeast of Center No None Detected0734.31-PLM-17 Gray Flashing Patch Mastic Southwest of Center No None Detected0734.31-PLM-18 Gray Flashing Patch Mastic Southwest of Center No 10% Chrysotile

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 200Sample Date: May 16, 2018

Dominion Project Number: 0734.31

0734.31-PLM-7 AC Pad - Southeast

0734.31-PLM-8 AC Pad - East

0734.31-PLM-9 AC Pad - Northeast

Page 30: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 300 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content0734.31-PLM-1 Black Felt Under Metal Roof East of Center No None Detected0734.31-PLM-2 Black Felt Under Metal Roof Southwest No None Detected0734.31-PLM-3 Black Felt Under Metal Roof Northwest No None Detected0734.31-PLM-4 Metal Roof Seam Caulking East of Center No <1% Chrysotile0734.31-PLM-5 Metal Roof Seam Caulking Southwest No <1% Chrysotile0734.31-PLM-6 Metal Roof Seam Caulking Northwest No <1% Chrysotile

White Roll-On Roof C/S - Gray/White Roofing Material (Membrane) No None Detected

Green Coating No None DetectedBlack Tape No None Detected

Black Roofing Mastic No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None DetectedWhite Roll-On Roof C/S -

Gray/White Roofing Material (Membrane) No None Detected

Green Coating No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None DetectedWhite Roll-On Roof C/S -

Gray/White Roofing Material (Membrane) No None Detected

Green Coating No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar & Felt No None DetectedBlack Roofing Tar & Felt No None Detected

Penetration Mastic - White No None DetectedSilver Paint No <1% Chrysotile

Black Roofing Mastic No <1% ChrysotilePenetration Mastic - White No None Detected

Silver Paint No <1% ChrysotileBlack Roofing Mastic No <1% Chrysotile

0734.31-PLM-10

0734.31-PLM-11

AC Pad - Southeast

AC Pad - North

0734.31-PLM-7 AC Pad - Southeast

0734.31-PLM-8 AC Pad - North

0734.31-PLM-9 AC Pad - Southwest

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 300Sample Date: May 17, 2018

Dominion Project Number: 0734.31

Page 31: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 300 - Page 2

Sample Number Material Description Sample Location Friable Asbestos Content

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 300Sample Date: May 17, 2018

Dominion Project Number: 0734.31

Penetration Mastic - White No None DetectedGreen Coating No None Detected

Black Roofing Mastic No None Detected0734.31-PLM-13 White Vent Caulking South No <1% Chrysotile

White Vent Caulking No 4% ChrysotileTan Vent Caulking No <1% Chrysotile

White Vent Caulking No 4% ChrysotileTan Vent Caulking No <1% Chrysotile

0734.31-PLM-16 Gray Vent Caulking Southeast No 5% Chrysotile0734.31-PLM-17 Gray Vent Caulking Southwest No 5% Chrysotile0734.31-PLM-18 Gray Vent Caulking Southwest of Center No 5% Chrysotile

0734.31-PLM-15 South

0734.31-PLM-12

0734.31-PLM-14 South

Northwest of Center

Page 32: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 300 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content

0734.31-PLM-1 Metal Roof Seam Caulking East of Center No 2% Chrysotile0734.31-PLM-2 Metal Roof Seam Caulking Southwest No 2% Chrysotile0734.31-PLM-3 Metal Roof Seam Caulking Northwest No 2% Chrysotile

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 300Sample Date: May 22, 2018

Dominion Project Number: 0734.31

Page 33: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 400 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content0734.31-PLM-1 Black Felt Under Metal Roof Northeast of Center No None Detected0734.31-PLM-2 Black Felt Under Metal Roof Northwest No None Detected0734.31-PLM-3 Black Felt Under Metal Roof Southwest No None Detected0734.31-PLM-4 Metal Roof Seam Caulking Northeast of Center No <1% Chrysotile0734.31-PLM-5 Metal Roof Seam Caulking Northwest No <1% Chrysotile0734.31-PLM-6 Metal Roof Seam Caulking Southwest No <1% Chrysotile

White Roll-On Roof C/S - White Roofing Material No None DetectedBlack Roofing Shingle w/White Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None Detected

White Roll-On Roof C/S - White Roofing Material No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None Detected

White Roll-On Roof C/S - White Roofing Material No None DetectedBlack Roofing Shingle w/Gray Pebbles No None Detected

Black Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None Detected

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 400Sample Date: May 17, 2018

Dominion Project Number: 0734.31

0734.31-PLM-7 AC Pad - East of Center

0734.31-PLM-8 AC Pad - East

0734.31-PLM-9 AC Pad - Northeast

Page 34: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 400 - Page 2

Sample Number Material Description Sample Location Friable Asbestos Content

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 400Sample Date: May 17, 2018

Dominion Project Number: 0734.31

Penetration Mastic - White No None DetectedBlack Mastic No None Detected

Penetration Mastic - Light Green No None DetectedBlack Mastic No None Detected

Penetration Mastic - Light Green No None DetectedBlack Mastic No None Detected

0734.31-PLM-13 White Vent Caulking Northeast No <1% Chrysotile0734.31-PLM-14 White Vent Caulking Southwest No None Detected0734.31-PLM-15 White Vent Caulking Southwest No None Detected0734.31-PLM-16 Gray Vent Caulking East of Center No None Detected0734.31-PLM-17 Gray Vent Caulking East of Center No None Detected0734.31-PLM-18 Gray Vent Caulking East of Center No None Detected

0734.31-PLM-10

0734.31-PLM-11

0734.31-PLM-12

AC Pad - East of Center

AC Pad - East

AC Pad - Northeast

Page 35: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 400 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content

0734.31-PLM-1 Metal Roof Seam Caulking Northeast of Center No <1% Chrysotile0734.31-PLM-2 Metal Roof Seam Caulking Northwest No <1% Chrysotile0734.31-PLM-3 Metal Roof Seam Caulking Southwest No <1% Chrysotile

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 400Sample Date: May 22, 2018

Dominion Project Number: 0734.31

Page 36: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 500 - Page 1

Sample Number Material Description Sample Location Friable Asbestos Content

0734.31-PLM-1 Black Felt Under Metal Roof Northwest No None Detected0734.31-PLM-2 Black Felt Under Metal Roof North No None Detected0734.31-PLM-3 Black Felt Under Metal Roof Northeast No None Detected0734.31-PLM-4 Metal Roof Seam Caulking Northwest No 3% Chrysotile0734.31-PLM-5 Metal Roof Seam Caulking North No 3% Chrysotile0734.31-PLM-6 Metal Roof Seam Caulking Northeast No 3% Chrysotile

White Roll-On Roof C/S - White Roofing Material No None DetectedGreen Roofing Material No None Detected

Black Roofing Shingle w/Gray Pebbles No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None Detected

White Roll-On Roof C/S - White Roofing Material No None DetectedGreen Roofing Material No None Detected

Black Roofing Shingle w/Gray Pebbles No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None Detected

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 500Sample Date: May 17, 2018

Dominion Project Number: 0734.31

0734.31-PLM-7 AC Pad - West

0734.31-PLM-8 AC Pad - Center

Page 37: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

DOMINION ENVIRONMENTAL CONSULTANTS, INC.PLM Bulk Sample Summary

PLM - Polarized Light MicroscopyPC - Point Count Building 500 - Page 2

Sample Number Material Description Sample Location Friable Asbestos Content

Client: Cave Creek Unified School District No. 93

Site: Black Mountain Elementary School - Building 500Sample Date: May 17, 2018

Dominion Project Number: 0734.31

White Roll-On Roof C/S - White Roofing Material No None DetectedGreen Roofing Material No None Detected

Black Roofing Shingle w/Gray Pebbles No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None DetectedBlack Roofing Felt No None DetectedBlack Roofing Tar No None Detected

Penetration Mastic - White No None DetectedGreen Mastic No None DetectedBlack Mastic No None Detected

Penetration Mastic - White No None DetectedGreen Mastic No None DetectedBlack Mastic No None Detected

Penetration Mastic - White No None DetectedGreen Mastic No None Detected

No None Detected0734.31-PLM-13 Parapet Wall Beam Caulking Northwest No None Detected0734.31-PLM-14 Parapet Wall Beam Caulking North No None Detected0734.31-PLM-15 Parapet Wall Beam Caulking Northeast No None Detected

0734.31-PLM-11

0734.31-PLM-12

0734.31-PLM-10 AC Pad - West

AC Pad - Center

AC Pad - East

0734.31-PLM-9 AC Pad - East

Page 38: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 5

Ë

PLM BULK SAMPLELOCATION MAPS

Page 39: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 100

Roof

PLM Bulk Sample Location Map (1 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

1

2

3

4

5

6

7

8

9

1011 12

13

14

15

1617

18

19

20

21

22

23

2425

26

27

28

29

30

31

3233

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Page 40: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 200

Roof

PLM Bulk Sample Location Map (2 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

1,4

2,5

3,6

7

8

9

10

11

12

13

14

15

16

1718

Not to Scale

NLynnDiesel

TMC

Building 200

Page 41: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 300

Roof

PLM Bulk Sample Location Map (3 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

1,4

2,5

3,6

7

8

910

11

12

13

14

1516

17

18

1

2

3

Not to Scale

NLynnDiesel

TMC

Building 300

Sample Date:May 17, 2018 Sample Date:

May 22, 2018

Page 42: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 400

Roof

PLM Bulk Sample Location Map (4 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

1,4

2,5

3,6

78

9

10 11

12

13

1415

16,17,18

1

2

3

Not to Scale

NLynnDiesel

TMC

Building 400

Sample Date:May 17, 2018

Sample Date:May 22, 2018

Page 43: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 500

Roof

PLM Bulk Sample Location Map (5 of 5)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

1,4

2,5 3,6

7 8 9

10 11 12

1314 15

Not to Scale

NLynnDiesel

TMC

Building 500

Page 44: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 6

Ë

PLM LABORATORYANALYSIS REPORTS

Page 45: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. School Bldg 100EML ID: 1928909

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-16-2018 and 05-17-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1928909, Page 1 of 11Aerotech Laboratories, Inc

Page 46: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 33Total Samples Analyzed: 33

Total Samples with Layer Asbestos Content > 1%: 9

Location: PLM-1, Black Felt Under Metal Roof Lab ID-Version‡: 9071862-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 65% CelluloseSample Composite Homogeneity: Good

Location: PLM-2, Black Felt Under Metal Roof Lab ID-Version‡: 9071863-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 65% CelluloseSample Composite Homogeneity: Good

Location: PLM-3, Black Felt Under Metal Roof Lab ID-Version‡: 9071864-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 65% CelluloseSample Composite Homogeneity: Good

Location: PLM-4, Tan Flashing Caulking Lab ID-Version‡: 9071865-1

Sample Layers Asbestos ContentTan Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-5, Tan Flashing Caulking Lab ID-Version‡: 9071866-1

Sample Layers Asbestos ContentTan Caulk ND

Sample Composite Homogeneity: Good

EMLab ID: 1928909, Page 2 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 47: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-6, Tan Flashing Caulking Lab ID-Version‡: 9071867-1

Sample Layers Asbestos ContentTan Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-7, White Coated Asphalt Roll On C/S Lab ID-Version‡: 9071868-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Brown Roofing Felt 35% ChrysotileBlack Roofing Tar ND

Black Roofing Shingle with White Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar ND

Composite Non-Asbestos Content: 5% Cellulose5% Glass Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1928909, Page 3 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 48: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-8, White Coated Asphalt Roll On C/S Lab ID-Version‡: 9071869-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Black Roofing Shingle with Gray Pebbles NDBlack Roofing Tar ND

Brown Roofing Felt 35% ChrysotileBlack Roofing Tar ND

Brown Roofing Felt 20% ChrysotileBlack Roofing Tar ND

Brown Roofing Felt 35% ChrysotileBlack Roofing Tar ND

Composite Non-Asbestos Content: 5% Cellulose5% Glass Fibers

Sample Composite Homogeneity: Poor

Location: PLM-9, White Coated Asphalt Roll On C/S Lab ID-Version‡: 9071870-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Black Roofing Shingle with Gray Pebbles NDBlack Roofing Tar ND

Brown Roofing Felt 35% ChrysotileBlack Roofing Tar ND

Brown Roofing Felt 20% ChrysotileBlack Roofing Tar ND

Brown Roofing Felt 35% ChrysotileBlack Roofing Tar ND

Composite Non-Asbestos Content: 5% Cellulose5% Glass Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1928909, Page 4 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 49: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-10, White Roll On C/S Lab ID-Version‡: 9071871-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Yellow Foam NDGray Non-Fibrous Material ND

Composite Non-Asbestos Content: 3% Glass FibersSample Composite Homogeneity: Poor

Location: PLM-11, White Roll On C/S Lab ID-Version‡: 9071872-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Yellow Foam NDGray Non-Fibrous Material ND

Composite Non-Asbestos Content: 3% Glass FibersSample Composite Homogeneity: Poor

Location: PLM-12, White Roll On C/S Lab ID-Version‡: 9071873-1

Sample Layers Asbestos ContentWhite Coating ND

Black Roofing Shingle with Multicolored Pebbles NDBlack Roofing Tar ND

Yellow Foam NDGray Non-Fibrous Material ND

Composite Non-Asbestos Content: 3% Glass FibersSample Composite Homogeneity: Poor

EMLab ID: 1928909, Page 5 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 50: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-13, Foam Coating Around A/C Lab ID-Version‡: 9071874-1

Sample Layers Asbestos ContentWhite Coating NDYellow Foam ND

Sample Composite Homogeneity: Moderate

EMLab ID: 1928909, Page 6 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 51: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-14, Foam Coating Around A/C Lab ID-Version‡: 9071875-1

Sample Layers Asbestos ContentWhite Coating NDYellow Foam ND

Sample Composite Homogeneity: Moderate

Location: PLM-15, Foam Coating Around A/C Lab ID-Version‡: 9071876-1

Sample Layers Asbestos ContentWhite Coating NDYellow Foam ND

Sample Composite Homogeneity: Moderate

Location: PLM-16, Silver Seam Mastic Lab ID-Version‡: 9071877-1

Sample Layers Asbestos ContentSilver Mastic 5% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-17, Silver Seam Mastic Lab ID-Version‡: 9071878-1

Sample Layers Asbestos ContentSilver Mastic 5% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1928909, Page 7 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 52: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-18, Silver Seam Mastic Lab ID-Version‡: 9071879-1

Sample Layers Asbestos ContentSilver Mastic 5% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-19, White Penetration Mastic Lab ID-Version‡: 9071880-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-20, White Penetration Mastic Lab ID-Version‡: 9071881-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-21, White Penetration Mastic Lab ID-Version‡: 9071882-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

EMLab ID: 1928909, Page 8 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 53: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-22, White Penetration Mastic Lab ID-Version‡: 9071883-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-23, White Penetration Mastic Lab ID-Version‡: 9071884-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-24, White Penetration Mastic Lab ID-Version‡: 9071885-1

Sample Layers Asbestos ContentWhite Roofing Mastic NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-25, White Flashing Caulking Lab ID-Version‡: 9071886-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

EMLab ID: 1928909, Page 9 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 54: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-26, White Flashing Caulking Lab ID-Version‡: 9071887-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-27, White Flashing Caulking Lab ID-Version‡: 9071888-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-28, Metal Roof Hood Caulking Lab ID-Version‡: 9071889-1

Sample Layers Asbestos ContentSilver Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-29, Metal Roof Hood Caulking Lab ID-Version‡: 9071890-1

Sample Layers Asbestos ContentSilver Caulk ND

Sample Composite Homogeneity: Good

EMLab ID: 1928909, Page 10 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 55: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 100

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-30, Metal Roof Hood Caulking Lab ID-Version‡: 9071891-1

Sample Layers Asbestos ContentSilver Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-31, Metal Roof Seam Caulking Lab ID-Version‡: 9071892-1

Sample Layers Asbestos ContentTan Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-32, Metal Roof Seam Caulking Lab ID-Version‡: 9071893-1

Sample Layers Asbestos ContentTan Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-33, Metal Roof Seam Caulking Lab ID-Version‡: 9071894-1

Sample Layers Asbestos ContentTan Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1928909, Page 11 of 11Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 56: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 57: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 58: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. School Bldg 200EML ID: 1928907

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-16-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1928907, Page 1 of 6Aerotech Laboratories, Inc

Page 59: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 200

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-16-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 18Total Samples Analyzed: 18

Total Samples with Layer Asbestos Content > 1%: 4

Location: PLM-1, Black Felt Under Metal Roof Lab ID-Version‡: 9071921-1

Sample Layers Asbestos ContentBlack Felt NDComposite Non-Asbestos Content: 85% CelluloseSample Composite Homogeneity: Good

Location: PLM-2, Black Felt Under Metal Roof Lab ID-Version‡: 9071922-1

Sample Layers Asbestos ContentBlack Felt NDComposite Non-Asbestos Content: 85% CelluloseSample Composite Homogeneity: Good

Location: PLM-3, Black Felt Under Metal Roof Lab ID-Version‡: 9071923-1

Sample Layers Asbestos ContentBlack Felt NDComposite Non-Asbestos Content: 85% CelluloseSample Composite Homogeneity: Good

Location: PLM-4, Metal Roof Seam Caulking Lab ID-Version‡: 9071924-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1928907, Page 2 of 6Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 60: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 200

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-16-2018

ASBESTOS PLM REPORTLocation: PLM-5, Metal Roof Seam Caulking Lab ID-Version‡: 9071925-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-6, Metal Roof Seam Caulking Lab ID-Version‡: 9071926-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-7, White Roll On C/S Lab ID-Version‡: 9071927-1

Sample Layers Asbestos ContentWhite Roofing Material Membrane ND

Black Roofing Tar and Felt and Pebbles NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 8% Glass Fibers2% Synthetic Fibers< 1% Cellulose

Sample Composite Homogeneity: Poor

Location: PLM-8, White Roll On C/S Lab ID-Version‡: 9071928-1

Sample Layers Asbestos ContentWhite Roofing Material Membrane ND

Black Roofing Tar and Felt and Pebbles NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 8% Glass Fibers2% Synthetic Fibers< 1% Cellulose

Sample Composite Homogeneity: Poor

EMLab ID: 1928907, Page 3 of 6Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 61: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 200

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-16-2018

ASBESTOS PLM REPORTLocation: PLM-9, White Roll On C/S Lab ID-Version‡: 9071929-1

Sample Layers Asbestos ContentWhite Roofing Material Membrane ND

Black Roofing Tar and Felt and Pebbles NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 8% Glass Fibers2% Synthetic Fibers< 1% Cellulose

Sample Composite Homogeneity: Poor

Location: PLM-10, White Penetration Mastic Lab ID-Version‡: 9071930-1

Sample Layers Asbestos ContentWhite Mastic ND

Sample Composite Homogeneity: Good

Location: PLM-11, White Penetration Mastic Lab ID-Version‡: 9071931-1

Sample Layers Asbestos ContentWhite Mastic ND

Sample Composite Homogeneity: Good

Location: PLM-12, White Penetration Mastic Lab ID-Version‡: 9071932-1

Sample Layers Asbestos ContentWhite Mastic ND

Sample Composite Homogeneity: Good

EMLab ID: 1928907, Page 4 of 6Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 62: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 200

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-16-2018

ASBESTOS PLM REPORTLocation: PLM-13, White Vent Caulking Lab ID-Version‡: 9071933-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-14, White Vent Caulking Lab ID-Version‡: 9071934-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-15, White Vent Caulking Lab ID-Version‡: 9071935-1

Sample Layers Asbestos ContentWhite Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-16, Gray Flashing Patch Mastic Lab ID-Version‡: 9071936-1

Sample Layers Asbestos ContentGray Mastic ND

Composite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Good

EMLab ID: 1928907, Page 5 of 6Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 63: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. School Bldg 200

Date of Sampling: 05-16-2018Date of Receipt: 05-16-2018Date of Report: 05-16-2018

ASBESTOS PLM REPORTLocation: PLM-17, Gray Flashing Patch Mastic Lab ID-Version‡: 9071937-1

Sample Layers Asbestos ContentGray Mastic ND

Composite Non-Asbestos Content: 10% CelluloseSample Composite Homogeneity: Good

Location: PLM-18, Gray Flashing Patch Mastic Lab ID-Version‡: 9071938-1

Sample Layers Asbestos ContentGray Mastic 10% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1928907, Page 6 of 6Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 64: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 65: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 66: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. Bldg 300EML ID: 1929623

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-18-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1929623, Page 1 of 8Aerotech Laboratories, Inc

Page 67: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 18Total Samples Analyzed: 18

Total Samples with Layer Asbestos Content > 1%: 5

Location: PLM-1, Black Felt Under Metal Roof Lab ID-Version‡: 9075644-1

Sample Layers Asbestos ContentBlack Roofing Felt with Brown Surface ND

Composite Non-Asbestos Content: 80% CelluloseSample Composite Homogeneity: Good

Location: PLM-2, Black Felt Under Metal Roof Lab ID-Version‡: 9075645-1

Sample Layers Asbestos ContentBlack Roofing Felt with Brown Surface ND

Composite Non-Asbestos Content: 80% CelluloseSample Composite Homogeneity: Good

Location: PLM-3, Black Felt Under Metal Roof Lab ID-Version‡: 9075646-1

Sample Layers Asbestos ContentBlack Roofing Felt with Brown Surface ND

Composite Non-Asbestos Content: 80% CelluloseSample Composite Homogeneity: Good

Location: PLM-4, Metal Roof Seam Caulking Lab ID-Version‡: 9075647-1

Sample Layers Asbestos ContentTan Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1929623, Page 2 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 68: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-5, Metal Roof Seam Caulking Lab ID-Version‡: 9075648-1

Sample Layers Asbestos ContentTan Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-6, Metal Roof Seam Caulking Lab ID-Version‡: 9075649-1

Sample Layers Asbestos ContentTan Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-7, White Roll on Roof C/S Lab ID-Version‡: 9075650-1

Sample Layers Asbestos ContentGray/White Roofing Material (Membrane) ND

Green Coating NDBlack Tape ND

Black Roofing Mastic NDBlack Roofing Shingle with Gray Pebbles ND

Black Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 5% Glass Fibers< 1% Cellulose< 1% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929623, Page 3 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 69: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-8, White Roll on Roof C/S Lab ID-Version‡: 9075651-1

Sample Layers Asbestos ContentWhite Roofing Material (Membrane) ND

Green Coating NDBlack Roofing Shingle with Gray Pebbles ND

Black Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 5% Glass Fibers< 1% Cellulose< 1% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929623, Page 4 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 70: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-9, White Roll on Roof C/S Lab ID-Version‡: 9075652-1

Sample Layers Asbestos ContentWhite Roofing Material (Membrane) ND

Green Coating NDBlack Roofing Shingle with Gray Pebbles ND

Black Roofing Tar and Felt NDBlack Roofing Tar and Felt ND

Composite Non-Asbestos Content: 5% Glass Fibers< 1% Cellulose< 1% Synthetic Fibers

Sample Composite Homogeneity: Poor

Location: PLM-10, Penetration Mastic Lab ID-Version‡: 9075653-1

Sample Layers Asbestos ContentWhite Roofing Mastic ND

Silver Paint < 1% ChrysotileBlack Roofing Mastic < 1% Chrysotile

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Poor

Comments: The silver paint is inseparable from the adjacent layers.

Location: PLM-11, Penetration Mastic Lab ID-Version‡: 9075654-1

Sample Layers Asbestos ContentWhite Roofing Mastic ND

Silver Paint < 1% ChrysotileBlack Roofing Mastic < 1% Chrysotile

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Poor

Comments: The silver paint is inseparable from the adjacent layers.

EMLab ID: 1929623, Page 5 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 71: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-12, Penetration Mastic Lab ID-Version‡: 9075655-1

Sample Layers Asbestos ContentWhite Roofing Mastic ND

Green Coating NDBlack Roofing Mastic ND

Composite Non-Asbestos Content: < 1% Cellulose< 1% Glass Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929623, Page 6 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 72: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-13, White Vent Caulking Lab ID-Version‡: 9075656-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-14, White Vent Caulking Lab ID-Version‡: 9075657-1

Sample Layers Asbestos ContentWhite Caulk 4% ChrysotileTan Caulk < 1% Chrysotile

Sample Composite Homogeneity: Moderate

Location: PLM-15, White Vent Caulking Lab ID-Version‡: 9075658-1

Sample Layers Asbestos ContentWhite Caulk 4% ChrysotileTan Caulk < 1% Chrysotile

Sample Composite Homogeneity: Moderate

Location: PLM-16, Gray Vent Caulking Lab ID-Version‡: 9075659-1

Sample Layers Asbestos ContentGray/Black Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1929623, Page 7 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 73: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 300

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-17, Gray Vent Caulking Lab ID-Version‡: 9075660-1

Sample Layers Asbestos ContentGray/Black Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-18, Gray Vent Caulking Lab ID-Version‡: 9075661-1

Sample Layers Asbestos ContentGray/Black Caulk 5% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1929623, Page 8 of 8Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 74: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 75: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 76: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mnt. Elem Bldg 300EML ID: 1931491

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-22-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1931491, Page 1 of 2Aerotech Laboratories, Inc

Page 77: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mnt. Elem Bldg 300

Date of Sampling: 05-22-2018Date of Receipt: 05-22-2018Date of Report: 05-22-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 3Total Samples Analyzed: 3

Total Samples with Layer Asbestos Content > 1%: 3

Location: PLM1, Metal Roof Seam Caulking Lab ID-Version‡: 9084817-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM2, Metal Roof Seam Caulking Lab ID-Version‡: 9084818-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM3, Metal Roof Seam Caulking Lab ID-Version‡: 9084819-1

Sample Layers Asbestos ContentOff-White Caulk 2% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1931491, Page 2 of 2Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 78: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 79: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. Bldg. 400EML ID: 1929620

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-18-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1929620, Page 1 of 7Aerotech Laboratories, Inc

Page 80: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 18Total Samples Analyzed: 18

Total Samples with Layer Asbestos Content > 1%: 0

Location: PLM-1, Black Felt Under Metal Roof Lab ID-Version‡: 9075670-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Good

Location: PLM-2, Black Felt Under Metal Roof Lab ID-Version‡: 9075671-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Good

Location: PLM-3, Black Felt Under Metal Roof Lab ID-Version‡: 9075672-1

Sample Layers Asbestos ContentBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Good

Location: PLM-4, Metal Roof Seam Caulking Lab ID-Version‡: 9075673-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1929620, Page 2 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 81: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-5, Metal Roof Seam Caulking Lab ID-Version‡: 9075674-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-6, Metal Roof Seam Caulking Lab ID-Version‡: 9075675-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-7, White Roll on Roof C/S Lab ID-Version‡: 9075676-1

Sample Layers Asbestos ContentWhite Roofing Material ND

Black Roofing Shingle with White Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929620, Page 3 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 82: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-8, White Roll on Roof C/S Lab ID-Version‡: 9075677-1

Sample Layers Asbestos ContentWhite Roofing Material ND

Black Roofing Shingle with Gray Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929620, Page 4 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 83: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-9, White Roll on Roof C/S Lab ID-Version‡: 9075678-1

Sample Layers Asbestos ContentWhite Roofing Material ND

Black Roofing Shingle with Gray Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

Location: PLM-10, Penetration Mastic Lab ID-Version‡: 9075679-1

Sample Layers Asbestos ContentWhite Mastic NDBlack Mastic ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-11, Penetration Mastic Lab ID-Version‡: 9075680-1

Sample Layers Asbestos ContentLight Green Mastic ND

Black Mastic NDComposite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-12, Penetration Mastic Lab ID-Version‡: 9075681-1

Sample Layers Asbestos ContentLight Green Mastic ND

Black Mastic NDComposite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Moderate

EMLab ID: 1929620, Page 5 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 84: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-13, White Vent Caulking Lab ID-Version‡: 9075682-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-14, White Vent Caulking Lab ID-Version‡: 9075683-1

Sample Layers Asbestos ContentBeige Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-15, White Vent Caulking Lab ID-Version‡: 9075684-1

Sample Layers Asbestos ContentBeige Caulk ND

Sample Composite Homogeneity: Good

Location: PLM-16, Gray Vent Caulking Lab ID-Version‡: 9075685-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Good

EMLab ID: 1929620, Page 6 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 85: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 400

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-18-2018

ASBESTOS PLM REPORTLocation: PLM-17, Gray Vent Caulking Lab ID-Version‡: 9075686-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Good

Location: PLM-18, Gray Vent Caulking Lab ID-Version‡: 9075687-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 5% CelluloseSample Composite Homogeneity: Good

EMLab ID: 1929620, Page 7 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 86: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 87: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 88: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. Bldg 400EML ID: 1931513

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-22-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1931513, Page 1 of 2Aerotech Laboratories, Inc

Page 89: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg 400

Date of Sampling: 05-22-2018Date of Receipt: 05-22-2018Date of Report: 05-22-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 3Total Samples Analyzed: 3

Total Samples with Layer Asbestos Content > 1%: 0

Location: PLM1, Metal Roof Seam Caulking Lab ID-Version‡: 9084916-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM2, Metal Roof Seam Caulking Lab ID-Version‡: 9084917-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM3, Metal Roof Seam Caulking Lab ID-Version‡: 9084918-1

Sample Layers Asbestos ContentOff-White Caulk < 1% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1931513, Page 2 of 2Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 90: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 91: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Approved by:

Approved SignatoryRenee Luna-Trepczynski

Report for:

Mr. Basilio MarcosDominion Environmental Consultants, Inc.20045 N. 19th Ave, Bldg 7Phoenix, AZ 85027

Regarding: Project: 0734.31; Black Mtn. Elem. Bldg. 500EML ID: 1929626

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:Asbestos PLM: 05-17-2018

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)

EMLab ID: 1929626, Page 1 of 7Aerotech Laboratories, Inc

Page 92: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTTotal Samples Submitted: 15Total Samples Analyzed: 15

Total Samples with Layer Asbestos Content > 1%: 3

Location: PLM-1, Black Felt Under Metal Roof Lab ID-Version‡: 9075616-1

Sample Layers Asbestos ContentBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-2, Black Felt Under Metal Roof Lab ID-Version‡: 9075617-1

Sample Layers Asbestos ContentBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-3, Black Felt Under Metal Roof Lab ID-Version‡: 9075618-1

Sample Layers Asbestos ContentBlack Roofing Tar NDBlack Roofing Felt ND

Composite Non-Asbestos Content: 35% CelluloseSample Composite Homogeneity: Moderate

Location: PLM-4, Metal Roof Seam Caulking Lab ID-Version‡: 9075619-1

Sample Layers Asbestos ContentTan Caulk 3% Chrysotile

Sample Composite Homogeneity: Good

EMLab ID: 1929626, Page 2 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 93: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-5, Metal Roof Seam Caulking Lab ID-Version‡: 9075620-1

Sample Layers Asbestos ContentTan Caulk 3% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-6, Metal Roof Seam Caulking Lab ID-Version‡: 9075621-1

Sample Layers Asbestos ContentTan Caulk 3% Chrysotile

Sample Composite Homogeneity: Good

Location: PLM-7, White Roll on Roof C/S Lab ID-Version‡: 9075622-1

Sample Layers Asbestos ContentWhite Roofing Material NDGreen Roofing Material ND

Black Roofing Felt with Gray Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929626, Page 3 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 94: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-8, White Roll on Roof C/S Lab ID-Version‡: 9075623-1

Sample Layers Asbestos ContentWhite Roofing Material NDGreen Roofing Material ND

Black Roofing Felt with Gray Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

EMLab ID: 1929626, Page 4 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 95: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-9, White Roll on Roof C/S Lab ID-Version‡: 9075624-1

Sample Layers Asbestos ContentWhite Roofing Material NDGreen Roofing Material ND

Black Roofing Felt with Gray Pebbles NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar NDBlack Roofing Felt NDBlack Roofing Tar ND

Composite Non-Asbestos Content: 7% Glass Fibers3% Synthetic Fibers

Sample Composite Homogeneity: Poor

Location: PLM-10, Penetration Mastic Lab ID-Version‡: 9075625-1

Sample Layers Asbestos ContentWhite Mastic NDGreen Mastic NDBlack Mastic ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Poor

Location: PLM-11, Penetration Mastic Lab ID-Version‡: 9075626-1

Sample Layers Asbestos ContentWhite Mastic NDGreen Mastic NDBlack Mastic ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Poor

EMLab ID: 1929626, Page 5 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 96: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-12, Penetration Mastic Lab ID-Version‡: 9075627-1

Sample Layers Asbestos ContentWhite Mastic NDGreen Mastic NDBlack Mastic ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Poor

EMLab ID: 1929626, Page 6 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 97: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EMLab P&K1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Dominion Environmental Consultants, Inc.C/O: Mr. Basilio MarcosRe: 0734.31; Black Mtn. Elem. Bldg. 500

Date of Sampling: 05-17-2018Date of Receipt: 05-17-2018Date of Report: 05-17-2018

ASBESTOS PLM REPORTLocation: PLM-13, Parapet Wall Beam Caulking Lab ID-Version‡: 9075628-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Good

Location: PLM-14, Parapet Wall Beam Caulking Lab ID-Version‡: 9075629-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Good

Location: PLM-15, Parapet Wall Beam Caulking Lab ID-Version‡: 9075630-1

Sample Layers Asbestos ContentGray/Black Caulk ND

Composite Non-Asbestos Content: 7% CelluloseSample Composite Homogeneity: Good

EMLab ID: 1929626, Page 7 of 7Aerotech Laboratories, Inc

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of allsamples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Page 98: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 99: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 100: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 7

Ë

ACM LOCATION MAPS

Page 101: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 100

Roof

Asbestos-Containing Material Location Map (1 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Asbestos-ContainingWhite Coated Asphalt Roll-On

Cross-Section(Brown Roofing Felt)

Page 102: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 100

Roof

Asbestos-Containing Material Location Map (2 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Asbestos-ContainingSilver Seam Mastic

Page 103: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 100

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (3 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Asbestos-ContainingMetal Roof Seam

Caulking

Page 104: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 200

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (4 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 200

Asbestos-ContainingMetal Roof Seam

Caulking

Page 105: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 200

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (5 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 200

Asbestos-ContainingGray Flashing Patch Mastic

Page 106: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (6 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

Asbestos-ContainingMetal Roof Seam

Caulking

Page 107: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (7 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

Asbestos-ContainingWhite Vent Caulking + Tan Vent Caulking;

Gray Vent Caulking

Page 108: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 500

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (8 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 500

Asbestos-ContainingMetal Roof Seam

Caulking

Page 109: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 8

Ë

OSHA UNCLASSIFIED <1% MATERIALLOCATION MAPS

Page 110: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (1 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

OSHA Unclassified <1%Penetration Mastic (Black)

& Silver Paint

Page 111: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 400

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (2 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 400

OSHA Unclassified <1%White Vent Caulking

Page 112: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.31Building 400

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (3 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 400

OSHA Unclassified <1%Metal Roof Seam Caulking

Page 113: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 9

Ë

EPA NESHAP NOTIFICATIONINFORMATION SHEET

Page 114: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

EPA NESHAP NOTIFICATION INFORMATION SHEET

Black Mountain Elementary SchoolRoofs-Buildings 100, 200, 300, 400 & 500

33606 North 60th StreetScottsdale, Arizona 85266

Property Owner Cave Creek UnifiedSchool District

Inspection Dates May 16, 17 & 22, 2018

Laboratory EMLab P&K.

Number of Samples 108 PLM 3 PC

Dates Analyzed May 16, 17, 18 & 22, 2018 (PLM)May 23, 2018 (PC)

Inspector Certification(s)

Name Basilio MarcosTraining Provider The Asbestos InstituteAHERA Certificate No. G 7264Expiration Date July 7, 2018

*See next page for list of analyzed ACM greater than one percent (>1%)

Page 115: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

List of Analyzed ACM greater than one percent (>1%)

ACM LocationNESHAPCategory

OSHARemoval

Classification

EstimatedQuantity

ActionRecommended

White Coated AsphaltRoll-On C/S

(Brown Roofing Felt)

Roof-Bldg. 100

Cat. I Class IIAmount

Undetermined atthis time

Abatement

Silver Seam MasticRoof-

Bldg. 100Cat. I Class II 100 sq. ft. Abatement

Metal Roof SeamCaulking

Roof-Bldg. 100

Cat. II Class IIAmount

Undetermined atthis time

Abatement

Gray Flashing PatchMastic

Roof-Bldg. 200

Cat. II Class II 10 sq. ft. Abatement

Metal Roof SeamCaulking

Roof-Bldg. 200

Cat. II Class IIAmount

Undetermined atthis time

Abatement

Metal Roof SeamCaulking

Roof-Bldg. 300

Cat. II Class IIAmount

Undetermined atthis time

Abatement

White Vent CaulkingRoof-

Bldg. 300Cat. II Class II 20 sq. ft. Abatement

Gray Vent CaulkingRoof-

Bldg. 300Cat. II Class II 20 sq. ft. Abatement

Metal Roof SeamCaulking

Roof-Bldg. 500

Cat. II Class IIAmount

Undetermined atthis time

Abatement

Page 116: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 10

Ë

GENERAL NOTES/EXCLUSIONS

Page 117: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

GENERAL NOTES/EXCLUSIONS

C Mr. Mike Santina, with the Cave Creek Unified School District #93 (CCUSD) outlined theareas and materials that are scheduled to be disturbed during the upcoming roof replacementactivities, instructed Dominion to only collect bulk samples of the outlined homogeneousmaterials, and have the samples analyzed by a qualified laboratory for the presence ofasbestos fibers.

C If any un-sampled suspect building materials are discovered during the roof replacementactivities, those materials should be properly sampled by a certified inspector prior to theirdisturbance

Page 118: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 11

Ë

INSPECTOR CERTIFICATIONS

Page 119: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 120: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

SECTION 12

Ë

LABORATORY CERTIFICATIONS

Page 121: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 122: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North
Page 123: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

ATTACHMENT BACM Location Maps

(including asbestos abatement details)

Page -9-

Page 124: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 100

Roof

Asbestos-Containing Material Location Map (1 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Remove asbestos-containingwhite coated asphalt roll-on

cross-section.All layers shall be

removed to the roof deck.

Page 125: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 100

Roof

Asbestos-Containing Material Location Map (2 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Remove asbestos-containingsilver seam mastic. The seam mastic

is on top of the asphalt roofing.

Page 126: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 100

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (3 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Not Sampled &Not Part of Scope

Building 100

Remove asbestos-containing metal roof seam caulking. Note: All metal roofing and black felt under the metal roofing with

residual seam caulking shall be removed and disposed as asbestos containing waste (ACW),

Page 127: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 200

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (4 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 200

Remove asbestos-containing metal roof seam caulking. Note: All metal roofing and black felt under the metal roofing with residual seam caulking shall be removed and disposed

as asbestos containing waste (ACW)

Page 128: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 200

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (5 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 200

Remove Asbestos-ContainingGray Patch Mastic

Page 129: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (6 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

Remove asbestos-containing metal roof seam caulking. Note: All metal roofing and black felt under the metal roofing with residual seam caulking

shall be removed and disposed as asbestos containing waste (ACW)

Page 130: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (7 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

Remove asbestos-containingwhite vent caulking and Gray vent caulking.

Page 131: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 500

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

Asbestos-Containing Material Location Map (8 of 8)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 500

Remove asbestos-containing metal roof seam caulking. Note: All metal roofing and black felt under the metal roofing with residual seam caulking shall be removed and disposed as asbestos containing waste (ACW),

Page 132: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 300

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (1 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 300

Remove OSHA Unclassified <1%Penetration Mastic (Black)

& Silver Paint

Page 133: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 400

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (2 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 400

OSHA Unclassified <1%White Vent Caulking

Page 134: TECHNICAL SPECIFICATIONS ASBESTOS …...TECHNICAL SPECIFICATIONS ASBESTOS ABATEMENT for Cave Creek Unified School District SITE LOCATION Black Mountain Elementary School 33606 North

Project No. 0734.34Building 400

Roof

Dominion Environmental Consultants, Inc.20045 North 19th Avenue, Building 7, Phoenix, AZ 85027 Office: (623) 516-1415 Fax: (623) 516-0017

OSHA Unclassified <1% Material Location Map (3 of 3)Black Mountain Elementary School33606 North 60th Street, Scottsdale, AZ 85266

Not to Scale

NLynnDiesel

TMC

Building 400

Remove OSHA Unclassified <1% metal roof seam caulking. Note: All metal roofing and black felt under the metal roofing with

residual seam caulking shall be removed and disposed as asbestos containing waste (ACW),