Technical Manual - Health Based Building
Transcript of Technical Manual - Health Based Building
P a g e | 1 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Technical Manual Magnum Board Rigid Air Barrier System
and
Magnum Board Weatherboard System (WBS)
Note: Always refer to this Technical Manual for correct installation procedures of Magnum Board for
use as a Rigid Air Barrier and Weatherboard System. For any intended use outside of this Technical Manual specification, you must refer directly to the Manufacturer/ Supplier of the product ‘Magnum Board’ – New Zealand Sustainable Forest Products LP for advice and written approval for ‘Specific Design ’ prior to specification or installation of Magnum Board use, as a Rigid Air Barrier and Weatherboard System.
Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Table of Contents
1. Product Description, Features and Benefits
2. Product Scope of Use
3. Product Limitations
4. NZBC relevant Performance Clauses
5. Engineer, Designer and Specification details
6. Technical Drawings
Product Application Requirements
7. Installation Procedures
8. Components and Accessories List
9. Workplace Health and Safety – MSDS
10. Maintenance
11. Warranty
12. Quality Management System
13. Index of Terms and Wording
Onsite Requirements
14. Installer / Applicator (Approved Training and Register)
15. Checklist – Pre and Post Installation, and Final
This Technical Manual is Divided into Products 1 and 2;
Product 1 – Magnum Rigid Air Barrier System, Stage 1
Product 2 – Magnum Weatherboard System (WBS), Stage 2
P a g e | 2 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP
P a g e | 3 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Product 1 - Magnum Board Rigid Air Barrier System
Stage 1 - Product Description, Features and Benefits (Rigid Air Barrier)
The Magnum Board Rigid Air Barrier system is a mineral sheet-based rigid air barrier to be used over timber framing or light gauge steel framing prior to cladding installation, for use in wind zones up to and including ‘extra -high’ as defined by NZS3604. It is designed to provide seamless weather-proofing and wind resistant protection of wall framing.
The system consists of Magnum Board installed vertically and the ABEP Blue Barrier* liquid flashing system applied to board joints. When installed together they provide an easy to install barrier to moisture and high winds.
Features
MAGNUM BOARD RIGID AIR BARRIER is a white mineral board with a number of attributes including moisture resistance. It is supplied in the following;
Magnum Board Sizes
2.4m x 1.2m x 9mm ; 2.7m x 1.2m x 9mm ; 3.0m x 1.2m x 9mm
Benefits
• Entirely breathable / vapour permeable
• NZ appraised performance inclusive of extra high wind zone
• Materials have been subjected to some of the world’s toughest testing regimes
• Superior weather tightness and durability
• High impact resistance
• Free of nasty chemicals
• Reduce energy use by removing dependency on mechanical air movement systems and
reduction in air moisture levels
• Increased indoor air quality
• Conventional construction and installation methods
• High resistance to fire, water, mould, condensation, and pests
• Amazing negative CO2 attributes
• Downstream waste management with no impact on the environment
• Consider cost neutral with whole home performance benefits
*The ABEP Blue Barrier Liquid Flashing is blue in colour used to seal all board joints, junctionsbetween the boards and window or door openings and pipe penetrations. The ABEP Blue BarrierLiquid Flashing System is supplied in 7.57 litre tubs.
Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Stage 1 - Product Scope of Use (Rigid Air Barrier)
The MAGNUM Board Rigid Air Barrier system has been designed for use behind cladding systems within the following scope:
Attached directly to new timber frame, designed and constructed in accordance with NZS 3604:2011 or galvanized steel framing, designed and constructed in accordance with wind zones up to and including ‘Extra High’ as per NZS 3604 Building Wind Zones.
The MAGNUM Board Rigid Air Barrier system shall be installed only by trained and approved applicators.
Stage 1 - Product Limitations (Rigid Air Barrier)
All edges must be supported by framing.
Magnum Building Products will assume no responsibility for water infiltration.
Stage 1 - NZBC Relevant Performance Clauses (Rigid Air Barrier)
Structural performance - Clause B1
The MAGNUM Board Rigid Air Barrier system when used in accordance with this Appraisal Certificate and subjected to normal conditions of environment and use, is expected to tolerate wind forces up to and including Extra High as defined in NZS 3604:2011.
Durability - Clause B2
The MAGNUM Board Rigid Air Barrier system when used in accordance with this Appraisal Certificate and subjected to normal conditions of environment and use is expected to have a serviceable life of at least 50 years according to the design option selected.
External Moisture - Clause E2
The installation of the MAGNUM Board Rigid Air Barrier system is reliant on the correct application of the ABEP Blue Barrier Liquid Flashing. The design of details not included within the Technical Manual are subject to specific design and are outside the scope of this Appraisal Certificate.
Hazardous Building Materials - Clause F2
Performance F2.3.1. The MAGNUM Board Rigid Air Barrier system when installed according to the requirements of this appraisal meets this requirement and will not present a health hazard to people using the building. P a g e | 4 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP
P a g e | 5 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Stage 1 - Engineer, Designer and Specification considerations (Rigid Air Barrier)
Designers are responsible for the framing design, and building contractors are responsible for the quality of construction of the framing.
The MAGNUM Board Rigid Air Barrier system is for use on new and existing timber framing to provide a wind and moisture resistant barrier when the building is situated in high to extra high wind zones.
Specification It is advised that the Architect/Designer or Specifier denote on the building/design plans for the purpose of identifying product use as follows;
Magnum Board Rigid Air Barrier System BEAL Appraisal C1405
A note should also be included directing all parties to where information can be obtained from our website.
Note: www.healthbasedbuilding.com for Technical Manual and Information on Magnum Board Rigid Air Barrier System
Stage 1 - Product Application Requirements (Rigid Air Barrier)
Installation Procedures
Storage Always lay Magnum Board Rigid Air Barrier on a solid surface and protect it from weather and dirt prior to and during installation. Always protect the corners of Magnum Board Rigid Air Barrier prior to and during installation. Do not stack other materials on top of Magnum Board Rigid Air Barrier.
Pre -Installation Installation of the MAGNUM Board Rigid Air Barrier sheets and ABEP Blue Barrier Liquid Flashing must be completed by New Zealand Sustainable Forest Products approved and trained tradesmen who have experience in the installation of Rigid Air Barriers.
It is the responsibility of the Rigid Air Barrier installer to inspect their workplace prior to beginning the installation of Magnum Board Rigid Air Barrier to ensure the installed work will meet the owner's / contractor's requirements.
Special Note: Notify owner / general contractor of any concerns prior to the start of Magnum Board Rigid Air Barrier installation.
The moisture content of any new timber framing must be no higher than 18%.
P a g e | 6 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Install Magnum Board Rigid Air Barrier to nominal 100 X 50 steel or timber framing members spaced a maximum of 600mm on centres
Magnum Board Rigid Air Barrier is to be installed vertically.
All edges must be supported by framing.
The application of the ABEP Blue Barrier Liquid Flashing must not be undertaken when the substrate temperature is below 4°C or if it is likely to drop below 4°C during drying/curing time.
Cutting Magnum Board Rigid Air Barrier You can easily cut Magnum Board with a carbine tipped scoring knife, keyhole saw, saber-saw or power saw equipped with a carbide blade and HEPA vacuum extraction.
Measure accurately and mark your cutting locations before cutting.
Make circular cuts and irregular angle cuts using a cement board bit or carbide tipped bit, a keyhole saw or a saber-saw.
To perform cut outs for electrical outlets, light receptacles, switches, etc., carefully measure and mark the location of the opening on the face of Magnum Board®. Outline the opening in pencil and cut it out with a keyhole saw or circle cutter equipped with carbide tipped tooling. The hole must be accurately located and cut to size.
Position cutting station so that wind will blow dust away from the user or others in the working area and allow for ample dust dissipation.
Score and snap using carbide-tipped scoring knife or utility knife (ability to use this method depends on thickness of Magnum Board being installed).
Fibre-cement shears (electric or pneumatic).
Dust-reducing circular saw equipped with appropriate blade and HEPA vacuum extraction.
Dust-reducing circular saw with appropriate saw blade.
Always use correct tools when executing cutting operations.
Even though Magnum Board is a non-toxic building material always wear a dusk mask, safety glasses and follow MSDS Guidelines.
Never use a power saw indoors.
Never use a circular saw blade that is inappropriate for the specific operation being undertaken.
Never use a grinder or continuous rim diamond blade for cutting.
Never dry sweep - use wet suppression methods or HEPA vacuum.
P a g e | 7 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Fig 1: HEPA extraction system with recommended cutting equipment
Magnum Board must be installed vertically using pneumatic nail or screw fasteners as per fixing detail below.
Fix at 15mm-20mm in from outside edges and 50mm in from corners. Ensure fixing at 300mm minimum spacing between fasteners and 600mm centres across 1200mm wide sheets.
Magnum Board Rigid Air Barrier can be installed rebate edge to rebate edge or square edge to square edge if the rebated edge has been removed.
Magnum Board Rigid Air Barrier is *pneumatically nailed to timber framing Magnum Board Rigid Air Barrier is **screwed to steel framing.
*Nails fixing is with a Paslode - Impulse Nail 65 x 2.8mm Stainless Steel Round Drive Paslode code B20560. TOOL: Paslode - Framemaster Impulse Nailer B20543 or B20540 with Paslode No Mar Tip (B20544G). Nails heads to be embedded flush with Magnum Board surface.
**Screwed fixing to steel framing using Simpson Strong-Tie PN WSCBGHLA114SA. TOOL: Quick Drive with PRO175 attachment. Available through Simpson Strong-Tie. Screws to be embedded Flush with Magnum Board surface.
Magnum Board Rigid Air Barrier must be joint sealed with ABEP Blue Barrier sealant to all butt joint to butt joints, all rebated edges and all cut outs supporting aspects such as pipework, also all external corners and all internal corners. Pre-priming to joins is not required. ABEP Blue Barrier Sealant must be applied using sealant gun. Raised sealant can be spread flat using conventional putty knife as per detail below. Sealant is not required over nail or screw heads.
Period of exposureSelected Cladding must be installed and coated within 90 days of Magnum Board Rigid Air Barrier installation. Selected cladding must comply with requirements NZBC.
NZS0090
50mm
50mm
50mm
50mm
50mm1200mm
2400mm
Mid Line
300mm
Maxim
um spacing betw
een fasteners
15-20mm
from edge
15-20mm
from edge
50mm
50mm
50mm
300mm
Maxim
um spacing betw
een fasteners
300mm
Maxim
um spacing betw
een fasteners
lifeInstall it for
Install it forh
ealth
Ma
gn
uM
Boa
rd d
etailed
Fixin
g in
stallatio
n d
iag
raM
P a g e | 9 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Product 2 - Magnum Board Weatherboard System (WBS)
Stage 2 - Product Description, Features and Benefits (WBS)
The Magnum Weatherboard System is made up of several key components, starting with;
1. timber framing or light gauge steel framing, for use in wind zones up to and including‘extra-high’ as defined by NZS3604
2. Magnum Board Rigid Air Barrier system which incorporates the ABEP Blue Barrier* liquidflashing system,
3. Vapour-permeable mineral sheet based Magnum weatherboard attached to H3.2 treatedtimber battens with specified nail fixings.
The complete system is designed to provide a vapour permeable, durable exterior cladding when over-coated with Foreverbreathe vapour-permeable coating finish.
Features MAGNUM BOARD Weatherboard is a white mineral board with a number of attributes including moisture resistance. It is supplied in the following;
Board Sizes:
3.0m x 195mm x 9mm
Benefits
• Entirely breathable / vapour permeable
• NZ appraised performance inclusive of extra high wind zone
• Materials have been subjected to some of the world’s toughest testing regimes
• Superior weather tightness and durability
• High impact resistance
• Free of nasty chemicals
• Reduce energy use by removing dependency on mechanical air movement systems and
reduction in air moisture levels
• Increased indoor air quality
• Conventional construction and installation methods
• High resistance to fire, water, mould, condensation, and pests
• Amazing negative CO2 attributes
• Downstream waste management with no impact on the environment
• Consider cost neutral with whole home performance benefits
P a g e | 10 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Stage 2 - Product Scope of Use (WBS)
The MAGNUM Weatherboards system has been appraised for use as an external cladding direct fixed over the Magnum Board Rigid Air Barrier system which is fixed over timber or light gauge steel framing within the following scope:
Used in conjunction with new timber or light gauge galvanized steel framing designed andconstructed to comply with the requirements of the NZBC; and,
Situated in wind zones up to, and including, ‘Extra High’ as per NZS 3604 Building WindZones
The MAGNUM Weatherboard system shall be installed only by trained and approved installers.
Product Limitations
The MAGNUM Weatherboard system must be installed over a Rigid Air Barrier, and is limited to use up to and including 10 metres in wall height.
The moisture content of any new or old timber framing must be no higher than 18%.
The installation of the MAGNUM Weatherboards system is reliant on the correct application of the Foreverbreathe coating system.
For all uses including “specific design” that fall outside of this Technical Manual and the Appraisal certificate, must be determined and approved by Engineers, Architects and/or Professionals in accordance with all relevant requirements of the New Zealand Building Code .
Stage 2 - NZBC Relevant Performance Clauses (WBS)
Structural performance - Clause B1
The MAGNUM Weatherboard system when used in accordance with this Appraisal Certificate and subjected to normal conditions of environment and use, is expected to tolerate wind forces up to and including Extra High as defined in NZS 3604:2011.
Durability - Clause B2
The MAGNUM Weatherboards system when used in accordance with this Appraisal Certificate and subjected to normal conditions of environment and use, is expected to have a serviceable life of at least 15 years for the Magnum Weatherboard substrate and 5 years for the protective coating system. Warranties of 20 years are available from New Zealand Sustainable Forest Products.
P a g e | 11 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
External Moisture - Clause E2
The installation of the MAGNUM Weatherboards system is reliant on the correct application of the Foreverbreathe coating system.
The design of details not included within the Technical Manual are subject to specific design and are outside the scope of the Appraisal Certificate.
Hazardous Building Materials - Clause F2
Performance F2.3.1. The MAGNUM Weatherboard system when installed according to the requirements of this appraisal meets this requirement and will not present a health hazard to people using the building.
Stage 2 - Engineer, Designer and Specification considerations
(WBS)
Designers are responsible for the framing design, and building contractors are responsible for the quality of construction of the framing.
The MAGNUM Weatherboard system is for use on new and existing timber framing to provide a wind and moisture resistant barrier when the building is situated in high to extra high wind zones.
Specification It is advised that the Architect/Designer or Specifier denote on the building/design plans for the purpose of identifying product use as follows;
Magnum Board Rigid Air Barrier and Weatherboard System BEAL Appraisal C1405
A note should also be included directing all parties to where information can be obtained from our website.
Note: www.healthbasedbuilding.com for Technical Manual and Information on Magnum Board Rigid Air Barrier and Weatherboard
System
P a g e | 12 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Stage 2 - Product Application Requirements (WBS)
Installation Procedures
Storage Always lay Magnum Board Weatherboard on a solid surface and protect it from weather and dirt prior to and during installation. Always protect all edges of Magnum Weatherboard prior to and during installation. Do not stack other materials on top of Magnum Board Weatherboard.
Pre -Installation Installation of the MAGNUM Weatherboard and components must be completed by New Zealand Sustainable Forest Products approved and trained tradesmen who have experience in the installation of Magnum Weatherboard system.
It is the responsibility of the Magnum Weatherboard system installer to inspect their work place prior to beginning the installation to ensure the installed work will meet the owner / contractors requirements.
Special Note: Notify owner / general contractor of any concerns prior to the start of Magnum Weatherboard system installation.
The moisture content of any new or existing timber framing must be no higher than 18%.
Install Magnum Weatherboard to a batten fixed over a nominal 100 X 50 steel or timber framing members spaced a maximum of 600mm on centres with a Rigid Air Barrier installed.
Magnum Weatherboard is to be installed horizontally.
Cutting Magnum Weatherboard You can easily cut Magnum Board with a carbide tipped scoring knife, keyhole saw, saber saw or power saw equipped with a carbide blade and HEPA vacuum extraction
Measure accurately and mark your cutting locations before cutting.
Make circular cuts and irregular angle cuts using a cement board bit or carbide tipped bit, a keyhole saw or a saber saw.
To perform cut outs for electrical outlets, light receptacles, switches, etc., carefully measure and mark the location of the opening on the face of Magnum Board®. Outline the opening in pencil and cut it out with a keyhole saw or circle cutter equipped with carbide tipped tooling. The hole must be accurately located and cut to size.
Position cutting station so that wind will blow dust away from the user or others in the working area and allow for ample dust dissipation.
P a g e | 13 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Score and snap using carbide-tipped scoring knife or utility knife (Ability to use this method depends on thickness of Magnum Board being installed.)
Fibre-cement shears (electric or pneumatic)
Dust-reducing circular saw equipped with appropriate blade and HEPA vacuum extraction. Dust
reducing circular saw with appropriate saw blade.
Always use correct tools when executing cutting operations.
Even though Magnum Weatherboard is a non-toxic building material always wear a dusk mask, safety glasses and follow MSDS Guidelines.
Never use a power saw indoors.
Never use a circular saw blade that is inappropriate for the specific operation being undertaken.
Never use a grinder or continuous rim diamond blade for cutting.
Never dry sweep - use wet suppression methods or HEPA vacuum.
Fixing Details
Magnum Board Weather Board must be installed horizontally to minimum 43mm x 20mm vertical battens using the fixing detail. see Fig 1
To help ensure proper alignment, use a 4 ft or longer level to check the first course.
P a g e | 14 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail : [email protected] http://www.healthbasedbuilding.com/magnum-board
Install a timber starter strip at the bottom of the structure to ensure a consistent plant angle throughout installation. Reference figure 2
Fig 2
For full length fixing a minimum of 50mm in from ends and 30mm down from the top edge is required and 400mm minimum spacing between fasteners.
Always install cut ends of Magnum Weatherboard to internal and external corners and window / doors openings with a maximum 40mm overhang to battens.
For full length fixing to minimum 43mm x 20mm battens Magnum Board Weather Board is pneumatically nailed. Nails are Paslode* Impulse Nail 65 x 2.8mm Stainless Steel Round Drive Paslode code B20550. Ensure nail heads to be embedded flush with Magnum Board surface
TOOL: Paslode* Framemaster Impulse Nailer B20543 or B20540 with Paslode No Mar (K) Tip (B20544G)
See Fig 3
Fig 3
Magnum Board Weather Boards must be installed with a minimum 40mm lap.
For butt end to butt end fixing Magnum Board must be pre-bored to match the nail dimension with nail positions a minimum of 20mm in from the butt edge and 30mm down from the top edge. Nails are stainless steel 435276. Refer Fig 4
P a g e | 15 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
It is a requirement to back-block butt end to butt end weatherboard joints on a minimum 65mm x 20mm battens with the batten extending to 200mm minimum above and below the board to be jointed. (note: this requirement is when a butt joint in the weatherboard appears between battens directly fixed over a stud) Refer Fig 4
Always end seal butt ends to be jointed with Foreverbreathe silicate paint or suitable alternative primer
Always butt join Magnum Board Weather Board with moderate edge contact. Refer Fig 4
Fig 4
External corners can be square cut for connection to corner soakers or timber
profiles to suit design details.
See fig 5
Fig 5
Butt End Joint
43 x 20mm 65 x 20mm 43 x 20mm
P a g e | 16 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Internal corners must be cut to match the natural angle of the Magnum Weatherboards as they meet.
See Fig 6
Fig 6
Internal corner flashings must be fitted. See Fig 7
Fig 7
https://www.e2flashingsolutions.co.nz/soakers-new/
Stage 2 - EXTERIOR Coating System - PREPARATION AND PAINTING PROCEDURES.
To retain vapour permeability Magnum Board Weather Board can be painted with Foreverbreathe exterior silicate paint. Product information sheets can be found at www.healthbasedbuilding.com
The application of the Foreverbreathe Coating system must not be undertaken when the substrate temperature is below 4°C or if it is likely to drop below 4°C during drying/curing time.
P a g e | 17 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Alternative non breathable paint options include Resene Stone Strenghtener as the primer and Resene acrylic tops coats. Product information can be found at www.resene.co.nz
Nuplex Fairing Crème can be used to fill minor gaps between joints or surface indentations.
Period of exposureMagnum Board Weather Boards must be painted within 30 days of installation to ensure best performance.
Product 1 and 2 - Technical Drawings (Rigid Air Barrier & WBS)
Drawings are available for Product 1 in Appendix A and Product 2 in Appendix B
All drawings are available for download within the technical manuals in the respective product listings at http://www.healthbasedbuilding.com/magnum-board
Magnum Board Rigid Air Barrier and Weatherboard System (WBS)
Component List
Product Description Photo Magnum Board Rigid Air Barrier
2.4 x 1.2 x 9mm 2.7 x 1.2 x 9mm 3.0 x 1.2 x 9mm
Magnum Board Weather Board 3.0 x 195 x 9mm
New Zealand Sustainable Forest Products LP
Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Sausage dispenser
Accessories List
Product Description Photo
Paslode Framemaster
Impulse Nailer Gun
Paslode* No-Mar (K) Tip
(Cat #B20544G)
P a g e | 18 25 – May – 2016 Version 3.0
Paslode Round Drive Nails 65x2.8MM SS Round Drive
Paslode code B20560
Mapei Sealant
Thermaflash Flashing Tape 75mm, 150mm, 200mm x23m rolls
New Zealand Sustainable Forest Products LP
Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
FX Exterior/Interior Plaster 10 Litre
Foreverbreathe Exterior
Silicate Paint
10 Litre
TERRA LANA WOOL
INSULATION
To Specification
HEALTH BASED BUILDING
COVER BOARDS AND
SCRIBERS
To Specification
P a g e | 19 25 – May – 2016 Version 3.0
P a g e | 20 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Workplace Health and Safety – MSDS (Rigid Air Barrier & WBS)
All products must be stored inside, in a well ventilated area, up off concrete floors, kept dry, out of direct sunlight and away from freezing conditions. The membrane products, in the original unopened containers, have a shelf life of 12 months from date of manufacture.
MSDS is in Appendix B
Maintenance (Rigid Air Barrier & WBS)
Product 1 – Once the Rigid Air Barrier system has been installed as per this Technical Manual and Appraisal certificate, no further maintenance is required.
Product 2 - Once the Magnum Weatherboard system has been installed as per this technical manual and as required by the NZBC, the exterior finish system (Foreverbreathe) will require periodic washing to remove air and wind driven pollution and salts. The exterior finish system will require re-application – refer to the manufacture of the exterior coating finish (Foreverbreathe) for recommendations.
Warranty (Rigid Air Barrier & WBS)
Warranty can be downloaded from our website at https://www.healthbasedbuilding.co.nz/documents/MagnumBoardWarrantyDocument30-year.pdf
Quality Management System the BPQP
The Quality Assurance program flow chat is available from our website https://www.healthbasedbuilding.co.nz/documents/MagnumBoardQualityAssuranceFlowchart.pdf
Index of Terms and Wording
Weatherboard System, is abbreviated to - WBS
Material Safety Data Sheet, is abbreviated to – MSDS
New Zealand Building Code, is abbreviated to – NZBC
P a g e | 21 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
New Zealand Standard, is abbreviated to – NZS
Product 1 and 2 - Onsite Requirements (Rigid Air Barrier & WBS)
Checklist – Pre and Post Installation, and Final
The checklist is in Appendix D
P a g e | 22 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Appendix A
50
BARGE - NO SOFFIT - SECTION DETAIL
35
1:5MAGNUM BOARD WEATHER BOARD
Y - Refer E2/AS1 Table 7
Z - R
efer
Tab
le7
E2/
AS
1
125mm min - Refer E2/AS1 Fig 45
1:5MAGNUM BOARD
PREFINISHED METAL BARGEFLASHING. CONFIRM MIN COVERREQUIREMENTS OVER WITH E2/AS1TABLE 7.
PROFILED SELECTED ROOFINGON ROOFING UNDERLAY
COMPRESSIBLE SEAL. CONFIRMIF REQUIRED WITH SELECTEDROOFING MANUFACTURER'SINSTRUCTIONS.
H3.2 200x18 FJ MCA FASCIA -BY HEALTH BASED BUILDING.PRE PRIMED.
9mm thick x 200mm MAGNUM BOARD®WEATHER BOARD. 40mm LAP TO TOP.ON H3.1 MCA Micro Pro Osmose 50 x20mm PINE TIMBER CAVITY BATTEN.PRE COAT BACK OF BATTEN WITHABEP BEP® Blue Barrier LIQUID APPLIEDFLASHING
9mm MAGNUM BOARD® RIGID AIRBARRIER
ROOF - WALL RIDGE - SECTION DETAIL
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
PROFILED SELECTED ROOFING ONROOFING UNDERLAY
FOLDED 0.55 BMTPREFINISHED METAL EAVESFLASHING WITH HEM AT TOPEDGE
SELECTED SPOUTING
35mm MIN EAVE FLASHINGOVERLAP
H3.2 150x18 FJ MCA FASCIA -BY HEALTH BASED BUILDING.PRE PRIMED.
WEATHERBOARD FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MMSS ROUND DRIVE. FIX AT EVERYCAVITY BATTEN, 600 CRS MAX.30mm FROM TOP OF BOARD.
ROOF STRUCTURE INACCORDANCE WITH NZS3504:2011OR SPECIFIC ENGINEERINGDESIGN.
PROVIDE SOLID BLOCKING FOR FIXING
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 MCA Micro Pro Osmose 50 x 20mm PINE TIMBER CAVITY BATTEN. PRIOR TO INSTALLATION. PRE COAT BACK OF BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
9mm MAGNUM BOARD® RIGID AIR BARRIER
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
WEATHERBOARD FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE. FIX AT EVERY CAVITY BATTEN, 600 CRS MAX. 30mm FROM TOP OF BOARD.
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
1
ENSURE ROOFING UNDERLAY IS LAIDHORIZONTALLY AND OVER TOP OF EAVESFLASHING.ENSURE ROOF FIXING DOES NOTPENETRATE EAVE FLASHING
EAVE WALL JUNCTION - SECTION DETAIL1:5MAGNUM BOARD WEATHERBOARDS
PROFILED SELECTED ROOFING ONROOFING UNDERLAY
35
125mm min - Refer E2/AS1 Fig 45
50
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
50mm MIN ROOFING OVERHANG
FOLDED 0.55 BMT PREFINISHED METAL EAVES FLASHING WITH HEM AT TOP EDGE
35mm MIN EAVE FLASHING OVERLAP
SELECTED GUTTER
H3.2 180x18 FJ MCA FASCIA - BY HEALTH BASED BUILDING. PRE PRIMED. GROOVED TO TAKE SOFFIT LININGS.
EAVE STRUCTURE IN ACCORDANCE WITH NZS3604:2011 OR SPECIFIC ENGINEERING DESIGN.
9mm MAGNUM BOARD® SOFFIT LINING. FLUSH STOPPED. FOREVERBREATHE SILICATE PAINT FINISH.
INTERIOR WALL LINING - 9mm MAGNUM BOARD® FOREVERBREATHE PAINT® FINISH
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY 300 crs AROUND PERIMETER, 50mm FROM CORNERS.15-20 FROM EDGE. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
9mm MAGNUM BOARD®RIGID AIR BARRIERRIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS. 15-20mm IN FROM EDGE. 50mm FROM CORNERS.
H3.1 EX 50x25mm PRE PRIMED TREATED SOFFIT MOULDING
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 MCA Micro Pro Osmose 50 x 20mm PINE TIMBER CAVITY BATTEN.
PRIOR TO INSTALLATION, PRE COAT BACK OF BATTEN WITH ABEP BEP®Blue Barrier LIQUID APPLIED FLASHING
WEATHERBOARD FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE. FIX AT EVERY CAVITY BATTEN, 600 CRS MAX. 30mm FROM TOP OF BOARD.
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS. 15-20mm IN FROM EDGE. 50mm FROM CORNERS.
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
2
35
12CONTINUOUS FLEXIBLE AIR SEAL ONPEF BACKING ROD TO PERIMETER OFOPENING.
FLOOR CONSTRUCTION: 19mm x 128mmT&G FOREVER BEECH ENGINEEREDFLOORING.ON 9mm MAGNUM BOARD,ON 240x45mm SG8 H1.2 TREATEDTIMBER FLOOR JOISTS AT 450mm CRSMAX. R1.9 UNDER FLOOR INSULATION90mm THICK.
FLEXIBLE FLASHING TAPE PERE2/AS1 2011 FIGURE 17b
2/240X45 HYSPAN JOISTS.
CAVITY CLOSER.
9mm MAGNUM BOARD RIGID AIRBARRIER
VERANDAH / DECK THRESHOLD - SECTION DETAIL1:5
50
25
EPDM WASHERS AT BOLTFIXINGS. ENSURE CLADDING ISSEALED PRIOR TO FIXINGPACKERS
DECK CONSTRUCTION 19mm THICKSELECTED HARDWOOD DECKINGON DECK JOISTS AT 400mm CRSMAX. FIXED TO STRINGER
TIMBER PACKER AT BOLT FIXINGS
DECK STRINGER & FIXINGS INACCORDANCE WITH NZS3604:2011OR SPECIFIC ENGINEERINGDESIGN
9mm thick x 200mm MAGNUM BOARD®WEATHER BOARD. 40mm LAP TO TOP.ON H3.1 MCA Micro Pro ® Osmose 50x20FJ TIMBER CAVITY BATTEN.PRIOR TO INSTALLATION, PRE COATBACK OF CAVITY BATTEN WITH ABEPBEP® Blue Barrier LIQUID APPLIEDFLASHING
12mm GAP BETWEEN STRINGERAND CLADDING/ JOINERY.NOTE: 20mm GAP IF DECK ISINDEPENDENTLY SUPPORTED
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
FIXINGS - PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVE PASLODECODE B20560. FIX AT EVERY CAVITYBATTEN, 600mm CRS MAX.
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
3
CANOPY JUNCTION - SECTION DETAIL1:5MAGNUM BOARD WEATHERBOARDS
35
Y - Refer Table 7 E2/AS1
755
MIN
GA
PM
INC
OV
ER
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP.ON H3.1 MCA Micro Pro Osmose 50 x 20mm PINE TIMBER CAVITY BATTEN.
9mm MAGNUM BOARD® RIGID AIR BARRIER
PRIOR TO INSTALLATION, PRE COAT BACK OF BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
ABEP® MULEHIDE TAPE APPLIED OVER TOP OF APRON FLASHING
CAVITY CLOSER. ALLOW 15mm DRIPEDGE TO BOTTOM OF CLADDING
PREFINISHED METAL APRON FLASHING. 75mm COVER BEHIND CLADDING. 35mm MIN CLEARANCE BETWEEN CLADDING AND FLASHING.REFER TO E2/AS1 TABLE 7 FOR COVER OVER ROOFING
5mm MAX. GAP BETWEEN FLASHINGAND ROOFING
ROOF STRUCTURE IN ACCORDANCEWITH NZS3504:2011 OR SPECIFIC ENGINEERING DESIGN.
TIMBER STRINGER FIXED TO WALL FRAMING. REFER TO NZS3604:2011
9mm MAGNUM BOARD® SOFFIT LINING. FLUSH STOPPED. FOREVERBREATHE SILICATE PAINT FINISH.
H3.1 EX 50x25mm PRE PRIMED TREATED SOFFIT MOULDING
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
WEATHERBOARD FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE. FIX AT EVERY CAVITY BATTEN, 600 CRS MAX. 30mm FROM TOP OF BOARD.INTERIOR WALL LINING - 9mmMAGNUM BOARD®. FOREVERBREATHEPAINT FINISH
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
4
50
15 min
CLADDING BASE - SECTION DETAIL1:5MAGNUM BOARD WEATHERBOARDS
50
15m
mm
in
INTERIOR WALL LINING - 9mm MAGNUM BOARD®. FOREVERRBEATHE PAINT FINISH
150
min
to fi
nish
ed p
avin
g.
REFER E2/AS1 FORTHRESHOLD DETAIL
DPC BETWEEN ALL TIMBERAND CONCRETE.
3030
CLADDING BASE - SECTION DETAIL1:5MAGNUM BOARD WEATHERBOARDS
6
6mm MIN GAP BETWEEN BACKOF RIGID AIR BARRIER ANDCONCRETE PERIMETER
FOREVERBREATHE SILICATE PAINT FINISH TO WEATHERBOARD.
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 43 MCA Micro Pro ® Osmose 50x20 FJ TIMBER CAVITY BATTEN. PRIOR TO INSTALLATION, PRE COAT BACK OF CAVITY BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
9mm MAGNUM BOARD ® RIGID AIR BARRIER
FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY CAVITY BATTEN, 600mm CRS MAX.
'Z' FLASHING AT MAGNUM BOARD RIGID AIR BARRIER JOINT. FOR WHERE SHEET LENGTHS EXCEED 2.4 OR 2.7m.
30mm FIXING FROM TOP OF WEATHER BOARD FOR SECRET FIXING.
CAVITY CLOSER. ALLOW 15mmMIN DRIP EDGE TO BOTTOM OF CLADDING
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
INTERIOR WALL LINING - 9mm MAGNUM BOARD®. FOREVERBREATHE PAINT FINISH
SELECTED HEALTH BASED BUILDING TIMBER SKIRTING. FOREVERBREATHE OIL FINISH
FLOOR CONSTRUCTION: 18mm FOREVER BEECH T&G FLOORING ON 9mm MAGNUM BOARD® FLOOR RIGID AIR BARRIER,ON TREATED TIMBER FLOOR JOISTS. R1.9 TERRA LANA®. UNDERFLOOR INSULATION 90mm THICK. FLOOR FRAMING SIZES PER NZS3604:2011 OR SPECIFIC DESIGN
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
TIMBER BEARER PER NZS3604
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
9mm MAGNUM BOARD® RIGIDAIR BARRIER
SELECTED HARDIE ANDTHOMPSON TIMBER SKIRTING. FOREVERBREATHE OIL FINISH
CONCRETE FLOOR SLAB
9mm x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 MCA Micro Pro ® Osmose 50x20 PINE TIMBER CAVITY BATTEN. FOREVERBREATHE SILICATE PAINT FINISH TO WEATHERBOARD.PRIOR TO INSTALLATION, PRECOAT BACK OF CAVITY BATTEN WITH ABEP BEP® Blue BarrierLIQUID APPLIED FLASHING
WEATHERBOARD FIXINGS -PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVE PASLODE CODE B20560.30mmFIXING FROM TOP OF WEATHER BOARD FOR SECRET FIXING.
CAVITY CLOSER. ALLOW 15mmDRIP EDGE TO BOTTOM OF CLADDING
50mm MIN CLADDINGOVERHANG
30
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
5
9mm MAGNUM BOARDRIGID AIR BARRIER
POWDERCOATEDALUMINIUM FLANGE PLATE
ABEP BEP® Blue Barrier JOINTFILLER SEALANT. 10mm WIDEX 6mm DEEP SEALANT ONBOND BREAKER.SEE E2/AS1FIG 68
TIMBER FRAMING WITHR3.2 (140mm thick)TERRA LANA®WOOL INSULATION.
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MMSS ROUND DRIVE PASLODE CODEB20560. FIX AT EVERY 300 crsAROUND PERIMETER, 50mm FROMCORNERS. REFER TO MAGNUMBOARD FIXING INSTALLATIONDIAGRAM.
75
PIPE PENETRATION - PLAN DETAILSCALE: 1:5
6
PIPE PENETRATION - SECTION DETAILSCALE: 1:5
PINE TIMBER CAVITY BATTEN H3.1 MCA Micro Pro ® Osmose 50x20 PRIOR TO INSTALLATION, PRE COAT BACK OF CAVITY BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
VANLUK RUBBER BOOTWITH ADHESIVE COLLAR. REFER TOwww.vanluk.co.nz
SOLID BLOCKINGAROUND PENETRATIONWITH MINIMUM 75mm OVERLAP TO RIGID AIR BARRIER
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY 300 crs AROUND PERIMETER, 50mm FROM CORNERS. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
WEATHERBOARD FIXINGS- PASLODE* IMPULSE NAIL65x2.8MM SS ROUNDDRIVE PASLODE CODEB20560. FIX AT EVERYCAVITY BATTEN.
SUPPORT PIPE WITH ANOG UNDER AND SCREWFIXED STRAP OVER
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS
BUTYL FLASHING OVERRUBBER BOOT PERVANLUK INSTALLATION INSTRUCTIONS
PINE TIMBER CAVITYBATTEN H3.1 MCA MicroPro ® Osmose 50x20
VANLUK RUBBER BOOTWITH ADHESIVE COLLAR.REFER TO www.vanluk.co.nz
9mm THICK x 200mm MAGNUM BOARD® WEATHER BOARD.
NOTE: ALTERNATIVE OPTIONIS TO REMOVE FLANGE PLATE AND PROVIDE CLEARSEALANT IN PLACE OF ABEPBlue Barrier JOINT FILLER.
9mm THICK x 200mm MAGNUMBOARD® WEATHER BOARD.
BUTYL FLASHING OVER RUBBERBOOT AS PER VANLUKINSTALLATION INSTRUCTIONS
ABEP BEP® Blue BarrierJOINT FILLER SEALANT TOTOP HALF OF FLANGE
ABEP BEP® Blue Barrier JOINTFILLER SEALANT10mm WIDE X 6mm DEEPSEALANT ON BONDBREAKER.SEE E2/AS1 FIG 68
PIPE PENETRATIONSLOPING TO OUTSIDEFLANGE PLATE
FIXINGS - PASLODE* IMPULSENAIL 65x2.8MM SS ROUND DRIVEPASLODE CODE B20560. FIX ATEVERY CAVITY BATTEN.
9mm MAGNUM BOARD®. RIGID AIR BARRIER. FIXINGS ARE PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
6
50
BARGE - NO SOFFIT - SECTION DETAIL
35
1:5MAGNUM BOARD WEATHER BOARD
Y - Refer E2/AS1 Table 7
Z - R
efer
Tab
le7
E2/
AS
1
125mm min - Refer E2/AS1 Fig 45
1:5MAGNUM BOARD
PREFINISHED METAL BARGEFLASHING. CONFIRM MIN COVERREQUIREMENTS OVER WITH E2/AS1TABLE 7.
PROFILED SELECTED ROOFINGON ROOFING UNDERLAY
COMPRESSIBLE SEAL. CONFIRMIF REQUIRED WITH SELECTEDROOFING MANUFACTURER'SINSTRUCTIONS.
H3.2 200x18 FJ MCA FASCIA -BY HEALTH BASED BUILDING.PRE PRIMED.
9mm thick x 200mm MAGNUM BOARD®WEATHER BOARD. 40mm LAP TO TOP.ON H3.1 MCA Micro Pro Osmose 50 x20mm PINE TIMBER CAVITY BATTEN.PRE COAT BACK OF BATTEN WITHABEP BEP® Blue Barrier LIQUID APPLIEDFLASHING
9mm MAGNUM BOARD® RIGID AIRBARRIER
ROOF - WALL RIDGE - SECTION DETAIL
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
PROFILED SELECTED ROOFING ONROOFING UNDERLAY
FOLDED 0.55 BMTPREFINISHED METAL EAVESFLASHING WITH HEM AT TOPEDGE
SELECTED SPOUTING
35mm MIN EAVE FLASHINGOVERLAP
H3.2 150x18 FJ MCA FASCIA -BY HEALTH BASED BUILDING.PRE PRIMED.
WEATHERBOARD FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MMSS ROUND DRIVE. FIX AT EVERYCAVITY BATTEN, 600 CRS MAX.30mm FROM TOP OF BOARD.
ROOF STRUCTURE INACCORDANCE WITH NZS3504:2011OR SPECIFIC ENGINEERINGDESIGN.
PROVIDE SOLID BLOCKING FOR FIXING
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 MCA Micro Pro Osmose 50 x 20mm PINE TIMBER CAVITY BATTEN. PRIOR TO INSTALLATION. PRE COAT BACK OF BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
9mm MAGNUM BOARD® RIGID AIR BARRIER
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS AND FIXING INSTALLATION DIAGRAM.
WEATHERBOARD FIXINGS -PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE. FIX AT EVERY CAVITY BATTEN, 600 CRS MAX. 30mm FROM TOP OF BOARD.
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
7
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
PLAN DETAIL - VERTICAL CONTROL JOINT1:2MAGNUM BOARD WEATHERBOARDS
INTERIOR WALL LINING - 9mm MAGNUM BOARD®. FOREVERBREATHE PAINT FINISH
10 -12mm MIN VERTICAL CONTROL JOINT. REQUIRED WHERE WALL EXCEEDS 6m IN LENGTH. FILL WITH ABEP BEP® Blue Barrier JOINT FILLER CONTINUOUS BEAD OF SEALANT
1mm THICK CONTINUOUS ABEP BEP® Blue Barrier LIQUID FLASHING APPLIED OVER MULEHIDE TAPE. EXTEND 25mm EITHER SIDE OF TAPE AND SEAL TO RIGID AIR BARRIER.
PINE TIMBER CAVITY BATTEN H3.1 MCA Micro Pro ® Osmose 50X20 FJ
METAL BACK SOAKER. FIX 150mm MIN FROM CENTRE OF STUD. OFFSET EACH SOAKER 600mm MIN FOR EACH BOARD COVER. REFER TO E2/AS1 FIGURE 87.
INTERIOR LINING FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY 300 crs AROUND PERIMETER, 50mm FROM CORNERS. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
TIMBER FRAMING WITH R3.2 (140mm thick) TERRA LANA®WOOL INSULATION.
9mm MAGNUM BOARD® RIGID AIR BARRIER.As per Table 23 and Clause 9.1.5 to 9.1.7.1 E2/AS1. RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE
50mm CONTINUOUS WIDTH OF MULEHIDE TAPE OVER JOINT IN MAGNUM RIGID AIR BARRIER BOARD
FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVEPASLODE CODE B20560. FIX ATEVERY CAVITY BATTEN. FIX 20mmMIN FROM END AT BUTT JOINT.
ABEP BEP® Blue Barrier JOINT FILLER CONTINUOUS BEAD OF SEALANT
10 - 12mm JOINT
50mm STRIP25 25
20
9mm THICK x 200mmMAGNUM BOARDWEATHER BOARD. NOTE:
1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED BY APPROVED INSTALLERS APPROVED BY NZSFP LTD.
2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®.
3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
8
EXTERNAL CORNER - PLAN DETAIL1:5MAGNUM BOARD WEATHERBOARDS - COVER BOARDS
50mm min. COVER
INTERNAL CORNER - PLAN DETAIL1:5MAGNUM BOARD WEATHERBOARDS - 'W' FLASHINGS
10
10
10
50 m
ax
INTERIOR WALL LINING -9mm MAGNUM BOARD® FOREVERBREATHE PAINT FINISHTIMBER FRAMING WITH R3.2 (140mm thick) TERRA LANA® WOOL INSULATION.
9mm MAGNUM BOARD® RIGID AIR BARRIER
65 X 65mm EXTERNAL CORNER BACK FLASHING.
H3.1 130x20 HEALTH BASED BUILDING COVER BOARDSAND SCRIBER CUT TO FIT WEATHERBOARD. 50mm MIN COVER OVER CLADDING
ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING OVER BUTT JOINT AT RIGID AIR BARRIER CORNER.
PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVE50MM FROM EDGE OF BOARD
PINE TIMBER CAVITY BATTENH3.1 MCA Micro Pro ® Osmose 50x20. ALLOW 10mm MIN GAPS BETWEEN BATTENS. PRIOR TO INSTALLATION, PRE COAT BACKOF BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING 10mm GAP BETWEEN CAVITY BATTENS9mm THICK x 200mm MAGNUM BOARD ® WEATHER BOARD.
INTERIOR WALL LINING - 9mm MAGNUM BOARD®FOREVERBREATHE PAINT FINISH
INTERIOR LINING FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY 300 crs AROUND PERIMETER, 50mm FROM CORNERS.15-20 FROM EDGE. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
ABEP BEP® Blue Barrier JOINT FILLER AT RIGID AIR BARRIER INTERNAL CORNER
PROPRIETARY uPVC 90°INTERNAL CORNER 'W' MOULD FLASHING WITH HEMS
10mm GAP BETWEEN CAVITY BATTENS
300
CR
S M
AX
TIMBER FRAMING WITH R3.2(140mm thick) TERRA LANA®WOOL INSULATION.
9mm MAGNUM BOARD®RIGID AIR BARRIER
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS. 15-20mm IN FROM EDGE.
PINE TIMBER CAVITYBATTEN H3.1 MCA Micro Pro® Osmose 50x20. PRIOR TO INSTALLATION, PRE COATBACK OF BATTEN WITHABEP BEP® Blue BarrierLIQUID APPLIED FLASHING
FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY CAVITY BATTEN.
9mm THICK X 200mm MAGNUM BOARD ® WEATHER BOARD.
50mmMIN
H3.1 TIMBER SCRIBERSEALED TO WEATHERBOARD
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS.
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVEPASLODE CODE B20560. FIXAT EVERY 300 crs AROUNDPERIMETER, 50mm FROMCORNERS.15-20 FROM EDGE.REFER TO MAGNUM BOARDFIXING INSTALLATIONDIAGRAM.
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTSTO BE INSTALLED BY APPROVED INSTALLERS.2.WHERE ABEP BEP® Blue Barrier IS IN CONTACT WITHBIOPIN® PAINT, CEMIX ACRYLBOND MUST BE APPLIED BEFOREAPPLICATION OF BIOPIN PAINT®
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
9
EXTERNAL CORNER - PLAN DETAIL 1:5MAGNUM BOARD WEATHERBOARDS - SOAKER FLASHINGS
15mm min. COVER
50
INTERIOR WALL LINING -9mm MAGNUM BOARD® FOREVERBREATHE® PAINT FINISH
TIMBER FRAMING WITH R3.2 (140mm thick) TERRA LANA® WOOL INSULATION.
9mm MAGNUM BOARD® RIGID AIR BARRIER
90° POWDERCOATED ALUMINIUM CORNER SOAKER. 15mm MIN COVER OVER WEATHERBOARD
ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING OVER BUTT JOINT AT RIGID AIR BARRIER CORNER.
PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE 50MM FROM EDGE OFBOARD
PINE TIMBER CAVITY BATTEN H3.2 MCA Micro Pro ® Osmose 50x20.
PRIOR TO INSTALLATION, PRE COAT BACK OF BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
9mm THICK x 200mm MAGNUM BOARD® WEATHER BOARD.
INTERNAL CORNER - PLAN DETAIL1:5MAGNUM BOARD WEATHERBOARDS - NOTCHED AND SCRIBED
10
10
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
INTERIOR WALL LINING - 9mm MAGNUM BOARD®FOREVERBREATHE FINISH
INTERIOR LINING FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY 300 crs AROUND PERIMETER, 50mm FROM CORNERS.15-20 FROM EDGE. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
ABEP BEP® Blue Barrier JOINT FILLER AT RIGID AIR BARRIER INTERNAL CORNER
65x65 uPVC INTERNAL CORNER BACK FLASHING
10mm GAP BETWEEN CAVITY BATTENS
50mmMIN
300
CR
S M
AX
TIMBER FRAMING WITH R3.2(140mm thick) TERRA LANA®WOOL INSULATION.
9mm MAGNUM BOARD®RIGID AIR BARRIER
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS. 15-20mm IN FROM EDGE.
PINE TIMBER CAVITYBATTEN H3.1 MCA Micro Pro® Osmose 50x20. PRIOR TO INSTALLATION, PRE COATBACK OF BATTEN WITHABEP BEP® Blue BarrierLIQUID APPLIED FLASHING
SCRIBED AND NOTCHED CORNER FOR WEATHERBOARDS
9mm THICK X 200mm MAGNUM BOARD ® WEATHER BOARD.
FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY CAVITY BATTEN.
65 X 65mm EXTERNAL CORNER ALUMINIUM BACK FLASHING.
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS.
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVEPASLODE CODE B20560. FIXAT EVERY 300 crs AROUNDPERIMETER, 50mm FROMCORNERS.15-20 FROM EDGE.REFER TO MAGNUM BOARDFIXING INSTALLATIONDIAGRAM.
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTSTO BE INSTALLED BY APPROVED INSTALLERS.2.WHERE ABEP BEP® Blue Barrier IS IN CONTACT WITHBIOPIN® PAINT, CEMIX ACRYLBOND MUST BE APPLIED BEFOREAPPLICATION OF BIOPIN PAINT®
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
10
TYPICAL HEAD - SECTION DETAIL1- 1:5
MAGNUM BOARD WEATHERBOARDS
U/S of Lintel
10 10
CONTINUOUS FLEXIBLE AIR SEAL ONPEF BACKING ROD TO PERIMETER OFOPENING
TEMPORARY PACKERS IF REQUIREDARE TO BE REMOVED AFTER FIXING
9mm thick x 200mm MAGNUM BOARD®WEATHER BOARD. 40mm LAP TO TOP.ON H3.1 MCA Micro Pro ® Osmose 50X20PINE TIMBER CAVITY BATTENON 9mm MAGNUM BOARD® RIGID AIRBARRIER
H3.1 TIMBER STARTING BLOCK TOSUIT
BOTTOM OF CLADDING MUST BEHARD DOWN ON TOP OFFLASHMAN JAMB FIN
FLASHMAN® EXTRUDEDALUMINIUM ONE PIECE CAVITYCLOSURE AND HEAD FLASHINGWITH STOP END (SHOWN DASHED)
FLASHMAN EXTRUDEDALUMINIUM JAMB FLASHING
35mm MIN FLASHING UPSTANDBEHIND CLADDING, AND 10mm MINCOVER OVER JOINERY
TYPICAL SILL - SECTION DETAIL2- 1:5
MAGNUM BOARD WEATHERBOARDS
3
10
CONTINUOUS FLEXIBLE AIR SEAL ONPEF BACKING ROD TO PERIMETER OFOPENING.
FOREVER BEECH® TIMBER REVEAL -CHOOSE SIZE + CODE
ABEP BEP® Blue Barrier LIQUIDAPPLIED SEALANT. APPLYACCORDING TO MANUFACTURER'SINSTRUCTION
ABEP BEP® Blue Barrier LIQUID APPLIEDFLASHING. APPLY ACCORDING TOMANUFACTURER'S INSTRUCTIONS
FOREVER BEECH TIMBERREVEAL - CHOOSE SIZE + CODE
FIXINGS - PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVE PASLODECODE B20560. FIX AT EVERY CAVITYBATTEN.
25
1035
min
15
10mm NOMINAL GAP
TIMBER PACKER AS REQUIRED.
14 GAUGE HOT DIP GALVANISED (316 SS WHERE REQUIRED) S.T.H.C SCREWS AT 600mm CRS WITH 65mm MIN FRAME PENETRATION. SUPPLIED AND INSTALLED BY FLASHMAN. REFER TO E2/AS1 FOR DURABILITY REQUIREMENTS
INTERIOR WALL LINING - 9mm MAGNUM BOARD® FOREVERBREATHE PAINT FINISH
TIMBER FRAMING WITH R3.2 (140mm thick) TERRA LANA® WOOL INSULATION.
FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. FIX AT EVERY CAVITY BATTENS, 600 CRS MAX. 30mm FROM TOP OF BOARD.
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
FLASHMAN® ALUMINIUM MITRE SOAKER SUPPLIED BY FLASHMAN
RIGID AIR BARRIER AND INTERIOR LINING FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS.
3mm GAP BETWEEN BOTTOM EDGE OF EXTRUDED ALUMINIUM FLANGE AND TOP OF FLASHMAN SILL
25mm FROM THE OUTSIDE FACE OF THE RIGID AIR BARRIER TO THE BACK OF THE ALUMINIUM WINDOW FRAME
FLASHMAN® EXTRUDED ALUMINIUM SLIMLINE SILL
BEAD OF SEALANT
FLASHMAN BACK PLATE
H3.1 PACKER SUPPLIED AND INSTALLED BY FLASHMAN
9mm thick x 200mm MAGNUM BOARD® WEATHER BOARD. 40mm LAP TO TOP. ON H3.1 MCA Micro Pro ® Osmose 50x20 PINE TIMBER CAVITY BATTEN ON 9mm MAGNUM BOARD® RIGID AIR BARRIER
INTERIOR LINING FIXINGS - PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE PASLODE CODE B20560. REFER TO MAGNUM BOARD FIXING INSTALLATION DIAGRAM.
TIMBER FRAMING WITH R3.2(140mm thick) TERRA LANAWOOL INSULATION.
INTERIOR WALL LINING - 9mmMAGNUM BOARD® FOREVERBREATHEPAINT FINISHPROPRIETARY TAPE OVER HEADFLASHING SUPPLIED ANDINSTALLED BY FLASHMAN
10mm GAP NOMINAL TO ALLOWFOR HEAD DEFLECTION ANDAIR SEAL
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
11
TYPICAL JAMB - PLAN DETAIL3- 1:5
MAGNUM BOARD WEATHERBOARDS
10
LINE OF FLASHMANSLIMLINE SILL BELOW
25
5
10
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
INTERIOR LINING FIXINGS -PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVEPASLODE CODE B20560.
10mm NOMINAL GAP
FOREVERBEECH®TIMBER REVEAL AND ARCHITRAVE
CONTINUOUS FLEXIBLE AIR SEAL ON PEF BACKING ROD TO PERIMETER OF OPENING.
TIMBER PACKER AS REQUIRED
ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING. APPLY ACCORDING TO MANUFACTURER'S INSTRUCTIONSELECTED ALUMINIUM JOINERY
HEAD FLASHING OVER (SHOWN DASHED)
POWDERCOATED ALUMINIUM J FLASHING10mm MIN JOINERY COVER OVER JAMB FLASHING
FLASHMAN® EXTRUDED 40mm ALUMINIUM JAMB FLASHING
INTERIOR WALL LINING -9mm MAGNUM BOARD®FOREVERBREATHE PAINT FINISH
TIMBER FRAMING WITH INSULATION
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS.
9mm MAGNUM BOARD®RIGID AIR BARRIER
PINE TIMBER CAVITYBATTEN H3.1 MCA Micro Pro® Osmose 50x20. PRIOR TO INSTALLATION, PRE COATBACK OF BATTEN WITHABEP BEP® Blue BarrierLIQUID APPLIED FLASHING
9mm THICK x 200mm MAGNUM BOARD® WEATHER BOARD. PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE 50MM FROM EDGE OF BOARD
BEAD OF SEALANTNOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
12
15m
mm
in g
ap
VERTICAL DETAIL - HORIZONTAL CONTROL JOINT1:5MAGNUM BOARD WEATHERBOARDS
35m
m M
IN
ABEP® MULEHIDE TAPE APPLIED OVER TOPOF JUNCTION FLASHING
9mm THICK X 200mm MAGNUM BOARD ®WEATHER BOARD.ON PINE TIMBER CAVITY BATTEN H3.1 MCAMicro Pro ® Osmose 50x20FIXINGS - PASLODE* IMPULSE NAIL65x2.8MM SS ROUND DRIVE PASLODECODE B20560. FIX AT EVERY CAVITYBATTEN.
H3.1 TIMBER STARTING BLOCK TO SUIT
CAVITY CLOSER
PURPOSE MADE ALUMINIUM POWDERCOATEDFLASHING 15° MIN SLOPE. REFER TABLE 20 OFE2/AS1 FOR FLASHING DURABILITY.15
35mm MIN COVER FLASHING OVERCLADDING. 15mm MIN GAP BETWEENCLADDING AND FLASHING.35
mm
10-1
2
2525
ENLARGED DETAIL - HORIZONTAL CONTROL JOINTN.T.SMAGNUM BOARD WEATHERBOARDS
9mm MAGNUM BOARD®RIGID AIR BARRIER.
© New Zealand Sustainable Forest Products LP
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
http://www.healthbasedbuilding.com/magnum-board
PRIOR TO INSTALLATION, PRE COAT BACK OF CAVITY BATTEN WITH ABEP BEP® Blue Barrier LIQUID APPLIED FLASHING
BOTTOM PLATE
FLOORING TO FINISH10mm BACK FROM OUTSIDE OF FRAMING
SOLID TIMBERBOUNDARY JOIST
FLOOR JOIST
9mm MAGNUM BOARD® RIGID AIR BARRIER. FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS. 15-20mm IN FROM EDGE.
TOP PLATE
WEATHERBOARD FIXED TO TOP PLATE.DO NOT FIX TO JOIST.
NOTE: THIS DETAIL IS REQUIRED TO LIMITCAVITIES TO A MAXIMUM OF 2 STORIESOR 7 METRES. REFER E2/AS1
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN®PRODUCTS TO BE INSTALLED BY INSTALLERSAPPROVED BY NZSFP LTD.2.WHERE ABEP BEP® Blue Barrier IS IN CONTACT WITHBIOPIN® PAINT, CEMIX ACRYLBOND MUST BE APPLIEDBEFORE APPLICATION OF BIOPIN PAINT®.3. HARDIE AND THOMSON® COVER BOARDS ANDSCRIBERS, BIOPIN PAINT®, TERRA LANA® WOOLINSULATION ARE SUPPLIED AND INSTALLED BYOTHERS.
RIGID AIR BARRIER FIXINGS: PASLODE* IMPULSE NAIL 65x2.8MM SS ROUND DRIVE . REFER TO MAGNUM BOARD RIGID AIR BARRIER TECHNICAL MANUAL SPECIFICATIONS
ABEP BEP® Blue Barrier JOINT FILLER. APPROVED BOND BREAKER IS APPLIED OVER THE BLUE BARRIER JOINT.
10 -12mm MIN HORIZONTALCONTROL JOINT. REQUIRED WHERE WALL EXCEEDS 2700mm IN HEIGHT
50mm CONTINUOUS WIDTH OF MULEHIDE TAPE OVER JOINT IN MAGNUM RIGID AIR BARRIER BOARD
1mm THICK CONTINUOUS ABEPBEP® Blue Barrier LIQUID FLASHING APPLIED OVER MULEHIDE TAPE. EXTEND 25mm EITHER SIDE OF TAPE AND SEAL TO RIGID AIR BARRIER.
50m
m M
ULE
HID
E
13
TIMBER FRAMED WALL
TERRA LANA WOOL INSULATION
9mm MAGNUM BOARD RIGID AIR BARRIER
H3.1 50X20 PINE TIMBER CAVITY BATTEN.PRIOR TO INSTALLATION PRE COAT BACK OF BATTEN WITH ABEP BEP BLUE BARRIER. 600mm CENTERS MAX. ALLOW TO TEMPORARILY FIX PRIOR TO WEATHERBOARD FIX.
65X2.8mm STAINLESS STEEL PASLODE IMPULSE NAIL. ROUND DRIVE. 30mm FROM TOP OF BOARD. FIXED AT EVERY CAVITY BATTEN
APEP BEP BLUE BARRIER LIQUID APPLIED FLASHING OVER BUTT JOINT AT RIGID AIR BARRIER CORNER
65x65 EXTERNAL CORNER BACK FLASHING
9mm X 200 MAGNUM BOARD WEATHERBOARD. FOREVERBREATHE PAINT FINISH.
H3.1 130X20 HEALTH BASED BUILDING COVER BOARDS AND SCRIBER CUT TO FIT WEATHERBOARD. 50mmMIN COVER OVER CLADDING
H3.1 TIMBER SCRIBER SEALED TO WEATHERBOARD
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
© New Zealand Sustainable Forest Products LPhttp://www.healthbasedbuilding.com/magnum-board
EXTERNAL CORNER - 3D DETAILNOT TO SCALE
NOTE:1. ALL MAGNUM BOARD®, ABEP® AND FLASHMAN® PRODUCTS TO BE INSTALLED
BY APPROVED INSTALLERS APPROVED BY NZSFP LTD. 2. WHERE ABEP BEP® BLUE BARRIER IS IN CONTACT WITH BIOPIN® PAINT, CEMIX
ACRYLBOND MUST BE APPLIED BEFORE APPLICATION OF BIOPIN PAINT®. 3. HARDIE & THOMSON® COVER BOARDS AND SCRIBERS, BIOPIN PAINT®, TERRA
LANA® WOOL INSULATION ARE SUPPLIED AND INSTALLED BY OTHERS.
14
RIGID AIR BARRIER FIXINGS: 65x2.8MMSTEEL PSTEEL PAASLSLODE IMPULSE NAIL.ODE IMPULSE NAIL. FIX FIX AAT 300mm CRS MAX T 300mm CRS MAX SSPPACINGSACINGS ON PERIMETER OF SHEEON PERIMETER OF SHEETT. REFER TECH. REFER TECHNICALNICAL MAMANNUUAL SPECIFIAL SPECIFICCAATIONTION
9mm MAGNUM BOARD INTERIOR LINING.
65x2.8mm STAINLESS STEEL PASLODE IMPULSE NAIL. ROUND DRIVE.
TERRA LANA INSULATION.
TIMBER FRAMED WALL140x45 TOP PLATE SHOWN.
FIX 50x50 FROM CORNERS.15-20mm FROM EDGE.300mm MAX SPACINGS BETWEENFIXINGS
INTERNAL CORNER - 3D DETAILNOT TO SCALE
MAGNUM BOARD WEATHER BOARD CLADDINGVERSION 01.00 SEPTEMBER 2015
© New Zealand Sustainable Forest Products LPhttp://www.healthbasedbuilding.com/magnum-board
14
P a g e | 23 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Appendix B
HOME of MAGNUM BOARD® “The New Generation GREEN Building Material”
“Install It for Health-Install It for Life”
Sheathing & Trim Products
Material Safety Data Sheet MSDS No.: MBGEP-032107-5 Page 1 of 8
Magnum Board® Brand Products SECTION 1: COMPANY AND PRODUCT INFORMATION
Magnum Building Products LLC 405 North Reo Street Tampa, FL 33609 USA
Phone: 813-304-2577
Facsimile: 813-304-2578
Website: www.magnumbp.com
Email: [email protected]
Use: Exterior: Sheathing, ceiling board, drop ceiling, siding, cladding and trim material.
Interior: Wallboard, ceiling board, tile backer board, underlayment and trim materials.
Structural Insulated Panels (SIPS) and Exterior Insulated Finish Systems (EIFS)
SECTION 2: COMPOSITION / INFORMATION ON INGREDIENTS
Ingredient CAS No. Hazard Class Magnesium Oxide 1309-48-4 None Magnesium Chloride 7786-30-3 None Cellulose 9004-34-6 None Perlite 93763-70-3 None
Proprietary Additives N/A None Fiberglass Scrim 65997-17-3 None
SECTION 3: HAZARDS IDENTIFICATION
Emergency Overview: Non-toxic, non explosive and is not a fire hazard.
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 2 of 8
Primary Routes of Entry: Eyes: Dust may irritate the eyes from mechanical abrasion causing watering and redness.
Skin: Dust may cause irritation of the skin from friction but cannot be absorbed through intact skin.
Ingestion:
Unlikely under normal conditions of use, but swallowing the dust from this product may result in irritation to the mouth and gastrointestinal tract.
Inhalation: Dust may cause irritation of the nose, throat, and airways, resulting in coughing and sneezing. Certain susceptible individuals may experience wheezing (spasms of the bronchial airways) on inhaling dust during sanding or sawing operations.
SECTION 4: FIRST AID MEASURES
EYES: Remove contact lens. Flush with running water or saline for at least 15 minutes. Seek medical attention if redness persists or if visual changes occur.
SKIN: Wash with mild soap and water. Contact physician if irritation persists or later develops.
INGESTION: If ingested, dilute by drinking large amounts of water. Do not induce vomiting. Seek medical attention. If unconscious, loosen tight clothing and lay the person on his / her side. Give nothing by mouth to an individual who is not alert and conscious. Seek medical attention.
INHALATION: Remove to fresh air. If shortness of breath or wheezing develops, seek medical
attention.
NOTES TO PHYSICIAN OR FIRST AID PROVIDERS: Treat symptomatically.
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 3 of 8
SECTION 5: FIRE-FIGHTING MEASURES
Magnum™ Building Products line of “Magnum Board®” Products are non flammable, non explosive and non combustible.
Fire and Explosion Hazard Flash Point: Not applicable. Auto-ignition: Not applicable
Extinguishing Media: This material is non combustible. Appropriate extinguishing media should be used for surrounding fire.
Fire Fighting: Fire fighting personnel should wear normal protective equipment.
SECTION 6: ACCIDENTAL RELEASE MEASURES
No special precautions are necessary to pick up product that has been dropped. The following applies only to spills or releases of dust generated during cutting or sanding Magnum Board®.
Precautions:
Good housekeeping practices are necessary for cleaning up areas where dust has been produced. Take measures to either eliminate or minimize the creation of dust.
Wherever possible, practices likely to generate dust should be controlled with engineering controls such as local exhaust ventilation, dust suppression with water and containment, enclosure or covers.
Cleanup Methods: A fine water spray may be used to suppress dust when sweeping (dry sweeping is not recommended). Vacuuming with an industrial vacuum cleaner outfitted with a high-efficiency particulate (HEPA) filter is recommended over sweeping. Waste may be disposed of by landfill in compliance with federal, provincial, state and local requirements governing non-toxic mineral materials
Avoid using materials and products that are incompatible with this product. (Refer to section 10.)
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 4 of 8
SECTION 7: HANDLING AND STORAGE
Handling and Storage Products in their intact state do not present a health hazard. The controls below apply to dust generated from the boards by cutting, drilling, routing, sawing, crushing, or otherwise abrading, and cleaning or moving sawdust.
Other Precautions: Even though Magnum Board® has been tested and deemed non toxic, Magnum Building Products recommends that exposure to dust be kept as low as
reasonably possible. Respirable levels should not exceed those specified by OSHA and MSHA and identified in this MISDS. Exposure to respirable (fine) dust depends on a variety of factors, including activity rate (i.e. cutting rate), method of handling (i.e. electric shears), environmental conditions (i.e. weather conditions, workstation orientation) and control measures used. Wherever possible, practices likely to generate dust should be carried out in well ventilated areas (i.e. outside). The work practices and engineering controls set out in Section 8 should be followed as precautions to reduce dust exposures.
SECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering Controls
Cutting Outdoors: 1. Magnum Building Products recommends positioning cutting station so
that wind will blow dust away from user or others in working area andallow for ample dust dissipation.
2. Use one of the following methods based on the required cutting rate andjobsite conditions.
Best
Score and snap using carbide-tipped scoring knife or utility knife(Ability to use this method depends on thickness of MagnumBoard® being installed.)
Fibercement board shears (electric or pneumatic).
Better
Dust reducing circular saw equipped with appropriate blade andHEPA vacuum extraction.
Good (for low to moderate cutting only)
Dust reducing circular saw with appropriate saw blade.
Always use correct tools when executing all cutting operations.
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 5 of 8
Ventilation: Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limit.
Respiratory Protection: Dust mask is recommended. .
Eye Protection: When cutting material, dust resistant safety goggles / glasses should be worn and used in compliance with ANSI Standard Z87.1-1-1989 and applicable
OSHA (i.e. 29 CFR 1910.133) standards.
Skin Protection: Loose comfortable clothing should be worn. Magnum Building Products recommends that direct skin contact with dust and debris be avoided when possible by wearing long sleeved shirts and long trousers, a cap or hat, and gloves.
Sanding / Drilling / Other Machining: If sanding, drilling, or other machining is conducted, Magnum Building Products recommends wear a NIOSH-approved dust mask.
Important Notes: 1. For maximum protection (lowest respirable dust production), Magnum
Building Products recommends always using “Best” level cuttingmethods where feasible.
2. Always use a circular saw blade that is appropriate for the specificoperation being undertaken.
3. Dry sweeping is not the preferred clean up method - Magnum BuildingProduction suggests wet suppression methods or HEPA vacuum.
4. It is not recommended that a grinder or continuous rim diamond bladebe used for cutting.
5. Always follow tool manufacturer’s safety recommendations.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Various colors depending on application, each with varying dimensions
according to product used.
Odor: Very mild
Physical State: Solid boards
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 6 of 8
Vapor Pressure: Not relevant.
Specific Gravity: Not relevant.
Flammability Limits: Not relevant.
Boiling Point: Not relevant
Melting Points: Not relevant.
Flash Point: Not relevant.
Auto-ignition Temperature: Not relevant.
Volatility: Not relevant.
Solubility in Water: Not relevant.
Evaporation rate: Not applicable.
NFPA Ratings (Scale 0 – 4) Health = 1 Flammability = 0 Reactivity = 0 Personal Protection = E
SECTION 10: STABILITY AND REACTIVITY
Stability: The Magnum Board products identified in section 1 are stable under ordinary conditions.
Conditions to Avoid: Excessive dust generation without proper dust mask protection.
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 7 of 8
Materials to Avoid: Incompatibility: Hydrofluoric acid will dissolve Magnesium Oxide and
can generate Magnesium Chloride fumes.
SECTION 11: TOLXICOLOGICAL INFORMATION
Magnum Board® products are non toxic in their intact form. The following applies to dust that may be generated during cutting and sanding.
Chronic Effects:
Inhaled: Repeated and prolonged overexposures to dust may cause increased risk of bronchitis. It is possible that repeated inhalation exposure to Magnum Board® fiber dust over time may lead to inflammation of the lungs in humans. All necessary precautions should be taken to prevent inhalation of dust to prevent these problems.
SECTION 12: ECOLOGICAL INFORMATION
Because Magnesium Oxide is a naturally occurring mineral, releases that may occur into the environment are not expected to leave any hazardous material that could cause a significant adverse impact.
SECTION 13: DISPOSAL CONSIDERATIONS
Dispose of material, as an inert, inorganic mineral, in conformance with federal, provincial, state and local regulations. Magnum Board® is not an RCRA hazardous waste.
SECTION 14: TRANSPORT INFORMATION
There are no special requirements for storage and transport of Magnum Board™.
UN No: None allocated Dangerous Goods Class: None allocated Hazchem Code: None allocated Poisons Schedule: None allocated Packing Group: Not applicable
Label: Not a DOT hazardous material.
SECTION 15: REGULATORY INFORMATION
DOT Hazard Classification: None
Placard Requirement: Not a DOT hazardous material.
MSDS No.: MBGEP-032107-5 Magnum Board® Brand Products
Page 8 of 8
CERCLA Hazardous Substance (40 CFR Part 302)
Listed substance: No Unlisted Substance: No Reportable Quantity (RQ): None Characteristic(s): Not applicable RCRA Waste Number: Not applicable
SECTION 16: OTHER INFORMATION
Preparation of Information and Disclaimer: This form has been prepared to meet current Federal OSHA hazard communication regulations and is offered without any warranty or guarantee of any type. Magnum Building Products cannot control the use of its products, and therefore specifically disclaims liability and responsibility arising from the use, misuse and/ or alteration of its products.
The information contained in this MSDS was produced without independent scientific or medical studies analyzing the effects of Magnum Board® dust upon human health. The information contained herein is based upon scientific and other data Magnum Building Products believes is valid and reliable and provides the basis for this MSDS. The information contained herein relates only to specific materials listed in the document. It does not address the effects of Magnum Board® dust when used in combination with other materials or substances, or when used in other processes. Because conditions of use are beyond Magnum Building Products control, the company makes no representations, guarantees or warranties, either express or implied warranties as to the fitness of the product for use, and assume no liability related to the information contained above.
Magnum Building Products requires, as a condition of use of its products, that purchasers comply with all applicable Federal, Provincial, State, and Local health and safety laws, regulations, orders, requirements, and strictly adhere to all instructions and warnings which accompany the product.
P a g e | 24 25 – May – 2016 Version 3.0
New Zealand Sustainable Forest Products LP Address: 10 Gannons Road, RD 1 Reefton, 7895
Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Appendix C
New Zealand Sustainable Forest Products LP 10 Gannons Road, RD 1 Reefton, 7895Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Checklist Pre-installation of Magnum Board Weatherboard
Magnum Board Rigid Air Barrier & Magnum Board Interior
NOTE:ItistheresponsibilityofthecertifiedinstallertoinspecttheirworkplacepriortobeginningtheinstallationofMagnumBoardWeatherBoardandMagnumBoardRigidAirBarriertoensuretheinstalledworkwillmeetthesupplier’srequirements.Notifyowner/generalcontractorofanyconcernspriortoinstallation.
CompanyName: JOB#AddressofJob:NameofContractor:Date/ /
CHECKLISTMagnumBoardRigidAirBarrier 1. Framingconfigurationandfixingdetail
2. Framingflushandlevel3. Truss&Roof/windowgangnailsorfixingsare
“recessed”intoframing4. Access&heights5. Servicesidentified6. HealthandSafetyplaninplace
MagnumBoardWeatherboard 1. Framingconfigurationandbattenpositioning2. Framing/battensflushandlevel3. Access&heights4. Servicesidentified5. HealthandSafetyplaninplace6. HealthandSafety7. Frameisstraight
MagnumBoardInterior 1. Framing/batten/blockingpositioning2. Prelineiscomplete3. Servicesidentified4. Access&Height5. RevealsorArchitraves6. Framing/battensareflushandlevel7. HealthandSafety
New Zealand Sustainable Forest Products LP 10 Gannons Road, RD 1 Reefton, 7895Phone 03 732 8414 E–Mail: [email protected] http://www.healthbasedbuilding.com/magnum-board
Checklist Final-installation of Magnum Board Weatherboard Magnum Board Rigid Air Barrier & Magnum Board
Interior NOTE:ItistheresponsibilityoftheinstallertoinspecttheirworkplacepriortobeginningtheinstallationofMagnumBoardWeatherBoardandMagnumBoardRigidAirBarriertoensuretheinstalledworkwillmeetthesupplier’srequirements.Notifyowner/generalcontractorofanyconcernspriortoinstallation.
Companyname: JOB#Addressofjob:NameofContractorDate / / Signature:
CHECKLISTMagnumBoardRigidAirBarrier
1. Fixingdetailsmatchrecommendedfixingpattern
2. AlignmentwithopeningstosuitABEPliquidflashings3. Sheetsingoodconditionandfixedflushwithfaceof
framework4. Wastematerialisremovedorpositionedforremoval
asnontoxicmaterial
MagnumBoardWeatherboard 1. Fixingdetailsmatchrecommendedfixingpattern2. Boardsarestraightandlevel3. Lapsaretight4. Wastematerialisremovedorpositionedforremoval
asnontoxicmaterial
MagnumBoardInterior 1. Fixingdetailsmatchrecommendedfixingpattern2. Sheetsconnectionsaretight3. Fixingscrewsarebelowplasteringlevel4. Wastematerialisremovedorpositionedforremoval
asnontoxicmaterial