Target lesion calcification in coronary artery disease: An ... · Target Lesion Calcification in...

7
JACC Vol. 20, No.5 November I, 1992:1149-55 1149 Target Lesion Calcification in Coronary Artery Disease: An Intravascular Ultrasound Study GARY S. MINTZ, MD, FACC, PHILLIPE DOUEK, MD, AUGUSTO D. PICHARD, MD, FACC, KENNETH M. KENT, MD, PHD, FACC, LOWELL F. SATLER, MD, FACC, JEFFREY J. POPMA, MD, FACC, MARTIN B. LEON, MD, FACC Washington, D.C. Objectives. The purpose of this study was to evaluate the frequency, amount and distribution of target lesion calcification in patients undergoing transcatheter therapy for symptomatic coro- nary artery disease. Background. Coronary artery target lesion calcification may be an important determinant of response to transcatheter therapy: balloon angioplasty causes dissections in calcified lesions, direc- tional atherectomy cuts calcium poorly, rotational atherectomy causes preferential ablation of calcium and laser irradiation effect may vary. Intravascular ultrasound imaging is a highly sensitive technique for detection of plaque calcification in vivo. Methods. We performed intravascular ultrasound imaging before or after, or both, various transcatheter therapies in 110 patients. These 84 men and 26 women had a mean age of 60 years and a duration of angina of 22 ± 34 months. Forty-nine patients had one-vessel, 29 had two-vessel, 25 had three-vessel and 7 had left main coronary disease. Vessels treated and imaged were the left main (n = 7), left anterior descending (n = 47), left circumflex (n = 18) and right (n = 38) coronary arteries. Results. Eighty-four patients (76%) had target lesion calcifica- Coronary artery calcification, particularly target lesion cal- cification, may be an important determinant of the arterial response to transcatheter therapy for coronary artery dis- ease (I). The barotrauma of balloon angioplasty causes dissections in calcified target lesions (2); the calcific deposits act as a wedge in creating cleavage planes through athero- sclerotic plaque (3). Directional atherectomy does not cut target lesion calcium well, and adjacent vessel calcification impedes passage of the device (4,5). Rotational atherectomy causes preferential ablation of calcified atherosclerotic plaque (6). Continuous wave laser irradiation is ineffective against calcium; in contrast, pulsed wave laser devices may partially ablate calcium (7). All conventional methods of detecting and localizing From the Department of Medicine, Cardiology Division, Washington Hospital Center, Washington, D.C. Manuscript received January 31, 1992; revised manuscript received April 9, 1992, accepted April 16, 1992. Address for correspondence: Martin B. Leon, MD, Washington Cardiol· ogy Center, 110 Irving Street, Northwest, No. 4B·14, Washington, D.C. 20010. ©1992 by the American College of Cardiology tion; 29 patients had one-quadrant, 25 had two-quadrant, 17 had three-quadrant and 13 had four-quadrant calcification. The cal- cification was superficial in 42 patients, deep in 13 and both superficial and deep in 31. The axial length of calcium could be measured in 29 patients; it was ::;5 mm in 11 and 2:6 mm in 18. Fluoroscopy detected calcification in 50 patients (48%, p < 0.001 vs. detection by ultrasound); this proportion increased to 74% in patients with calcification of two or more quadrants and to 86% in patients with calcification 2:6 mm in length of two or more quadrants. Calcification was more common in patients who smoked and tended to be more common in patients with multives- sel d!sease or previous coronary artery bypass graft surgery. Conclusions. We conclude that target lesion calcification occurs in 75% of patients with symptomatic coronary artery disease requiring angioplasty. Target lesion calcification is best detected, localized and quantified by intravascular ultrasound. These ob- servations may be important in selecting devices for transcatheter therapy. (J Am Coli CardioI1992;20:1149-55) coronary artery calcification have limitations. Intravascular ultrasound imaging permits analysis of coronary artery structure and atherosclerotic lesion morphology in a manner not possible previously. In'this study we report the use of this technique to determine the incidence and severity of target lesion calcification in patients undergoing transcathe- ter therapy for symptomatic coronary artery disease. Methods Patient group. We studied 110 patients undergoing trans- catheter therapy for symptomatic native coronary artery disease. Patients with a recent myocardial infarction and patients with saphenous vein graft disease were excluded. The clinical, angiographic and intravascular ultrasound rec- ords from these patients form the basis of this report. There were 84 men and 26 women with a mean age of 60 ± 10 years (range 38 to 77) and a duration of angina of 22 ± 34 months (range <1 month to 12 years). Hypertension was present in 63 patients and insulin·dependent diabetes in 13. There was a history of remote myocardial infarction in 38 0735·1097192/$5.00

Transcript of Target lesion calcification in coronary artery disease: An ... · Target Lesion Calcification in...

JACC Vol. 20, No.5 November I, 1992:1149-55

1149

Target Lesion Calcification in Coronary Artery Disease: An Intravascular Ultrasound Study

GARY S. MINTZ, MD, FACC, PHILLIPE DOUEK, MD, AUGUSTO D. PICHARD, MD, FACC, KENNETH M. KENT, MD, PHD, FACC, LOWELL F. SATLER, MD, FACC, JEFFREY J. POPMA, MD, FACC, MARTIN B. LEON, MD, FACC

Washington, D.C.

Objectives. The purpose of this study was to evaluate the frequency, amount and distribution of target lesion calcification in patients undergoing transcatheter therapy for symptomatic coro­nary artery disease.

Background. Coronary artery target lesion calcification may be an important determinant of response to transcatheter therapy: balloon angioplasty causes dissections in calcified lesions, direc­tional atherectomy cuts calcium poorly, rotational atherectomy causes preferential ablation of calcium and laser irradiation effect may vary. Intravascular ultrasound imaging is a highly sensitive technique for detection of plaque calcification in vivo.

Methods. We performed intravascular ultrasound imaging before or after, or both, various transcatheter therapies in 110 patients. These 84 men and 26 women had a mean age of 60 years and a duration of angina of 22 ± 34 months. Forty-nine patients had one-vessel, 29 had two-vessel, 25 had three-vessel and 7 had left main coronary disease. Vessels treated and imaged were the left main (n = 7), left anterior descending (n = 47), left circumflex (n = 18) and right (n = 38) coronary arteries.

Results. Eighty-four patients (76%) had target lesion calcifica-

Coronary artery calcification, particularly target lesion cal­cification, may be an important determinant of the arterial response to transcatheter therapy for coronary artery dis­ease (I). The barotrauma of balloon angioplasty causes dissections in calcified target lesions (2); the calcific deposits act as a wedge in creating cleavage planes through athero­sclerotic plaque (3). Directional atherectomy does not cut target lesion calcium well, and adjacent vessel calcification impedes passage of the device (4,5). Rotational atherectomy causes preferential ablation of calcified atherosclerotic plaque (6). Continuous wave laser irradiation is ineffective against calcium; in contrast, pulsed wave laser devices may partially ablate calcium (7).

All conventional methods of detecting and localizing

From the Department of Medicine, Cardiology Division, Washington Hospital Center, Washington, D.C.

Manuscript received January 31, 1992; revised manuscript received April 9, 1992, accepted April 16, 1992.

Address for correspondence: Martin B. Leon, MD, Washington Cardiol· ogy Center, 110 Irving Street, Northwest, No. 4B·14, Washington, D.C. 20010.

©1992 by the American College of Cardiology

tion; 29 patients had one-quadrant, 25 had two-quadrant, 17 had three-quadrant and 13 had four-quadrant calcification. The cal­cification was superficial in 42 patients, deep in 13 and both superficial and deep in 31. The axial length of calcium could be measured in 29 patients; it was ::;5 mm in 11 and 2:6 mm in 18. Fluoroscopy detected calcification in 50 patients (48%, p < 0.001 vs. detection by ultrasound); this proportion increased to 74% in patients with calcification of two or more quadrants and to 86% in patients with calcification 2:6 mm in length of two or more quadrants. Calcification was more common in patients who smoked and tended to be more common in patients with multives­sel d!sease or previous coronary artery bypass graft surgery.

Conclusions. We conclude that target lesion calcification occurs in 75% of patients with symptomatic coronary artery disease requiring angioplasty. Target lesion calcification is best detected, localized and quantified by intravascular ultrasound. These ob­servations may be important in selecting devices for transcatheter therapy.

(J Am Coli CardioI1992;20:1149-55)

coronary artery calcification have limitations. Intravascular ultrasound imaging permits analysis of coronary artery structure and atherosclerotic lesion morphology in a manner not possible previously. In'this study we report the use of this technique to determine the incidence and severity of target lesion calcification in patients undergoing transcathe­ter therapy for symptomatic coronary artery disease.

Methods Patient group. We studied 110 patients undergoing trans­

catheter therapy for symptomatic native coronary artery disease. Patients with a recent myocardial infarction and patients with saphenous vein graft disease were excluded. The clinical, angiographic and intravascular ultrasound rec­ords from these patients form the basis of this report.

There were 84 men and 26 women with a mean age of 60 ± 10 years (range 38 to 77) and a duration of angina of 22 ± 34 months (range <1 month to 12 years). Hypertension was present in 63 patients and insulin·dependent diabetes in 13. There was a history of remote myocardial infarction in 38

0735·1097192/$5.00

1150 MINTZ ET AL. TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

JACC Vol. 20, No.5 November 1,1992:1149-55

patients and of previous coronary artery bypass graft sur­gery in 18. Thirty-eight patients were smokers; two were on maintenance dialysis.

Forty-nine patients had one-vessel, 29 had two-vessel, 25 had three-vessel and 7 had left main coronary disease. Vessels treated and imaged were the left main (n == 7), left anterior descending (n == 47), left circumflex (n == 18) and right (n == 38) coronary arteries. Transcatheter therapeutic modalities were balloon angioplasty in 36 patients, stent placement (Johnson and Johnson Interventional Systems or Medtronic) in 8, excimer laser coronary angioplasty (Ad­vanced Interventional Systems) in 9, directional coronary atherectomy (Devices for Vascular Intervention) in 29, high speed rotational atherectomy (Heart Technology) in 25 and transluminal extraction catheter atherectomy (Interventional Technologies) in 3. All patients with sten! placement under­went imaging before the intervention.

Patients were studied after giving written, informed con­sent. Intravascular ultrasound imaging is performed as part of ongoing protocols approved by the Institutional Review Board of the Washington Hospital Center.

Fluoroscopic-angiographic study. The presence of calcifi­cation in the target lesion was evaluated during fluoroscopy before the ultrasound study was performed or by persons who did not know the ultrasound results. With use of digital electronic calipers, the percent angiographic diameter steno­sis was measured in orthogonal projections. The angio­graphic target lesion was defined as the entire length of lesion SUbjected to transcatheter device therapy. The mean percent angiographic diameter stenosis was 79 ± 12% (range 58% to 100%) before intervention.

Intravascular ultrasound imaging systems. We used the InterTherapy intravascular ultrasound imaging system incor­porating either a 20-MHz transducer-tip catheter within a 4.9F sheath or a 25-MHz transducer-tip catheter within a 3.9F sheath. Point to point resolution along the ultrasound beam axis was calculated to be 100 pm for the 20-MHz and 80 /-Lm for the 25-MHz catheter; the calculations are based on transducer frequency and wavelength and the speed of ultrasound transmission in tissue. The maximal penetration depth was 8 mm, which was also a function of the tissue type being imaged. Planar two-dimensional images were formed in real time by motor rotation of the entire transducer-tip catheter within the polyethylene imaging sheath at 1,800 rpm. In 40 patients, the 25-MHz tipped catheter was with­drawn within the imaging sheath at 0.5 mmis by a prototype motorized pullback device. At this pullback rate, contiguous image slices were 17 JLm apart. Studies performed in this manner provided source material for many of the illustra­tions in this study. Studies were recorded on high resolution 0.5-in. (1.27-cm) videotape for off-line analysis.

Three-dimensional reconstruction of the planar intravas­cular ultrasound images was possible in the 40 patients in whom imaging was performed with the motorized pullback mechanism. We used software developed by Pura and hard­ware from Image Comm. The software-encoded algorithm

Figure 1. Intravascular ultrasound images from six patients illustrat­ing patterns of calcium distribution. A, C and F, Superficial calcifi­cation (solid arrows). D, Deep calcification (open arrow). Band E, Superficial (solid arrow) and deep (open arrow) calcification. In A, the adventitia shadowed by the lesion calcification is reconstructed by a dotted line; the ultrasound catheter is shown by the long white arrow.

uses thresholding to render the three-dimensional image. The hardware can digitize 6 frames/so Parameters were set so that 12 image slices were stacked per mm of arterial length; 230 digitized images were used to reconstruct a segment of artery 19 mm long. Regions of interest were set to include all arterial structures between the adventitia and intima and to exclude the imaging sheath. The threshold was set just low enough to exclude blood echoes. Each arterial segment either was viewed as an intact cylinder or was split in half to be viewed as two hemicylinders.

Qualitative ultrasound. Calcification is detected as bright dense echoes (brighter than the reference adventitia) with acoustic shadowing of underlying tissue. Calcification is differentiated from dense fibrous tissue by the presence of acoustic shadowing. Dense fibrous tissue also causes bright echoes (as bright as or brighter than those of the reference adventitia but usually less bright than those of calcium), but usually without acoustic shadowing (8-1 Calcification was classified as 1) superficial if it involved the lumen-intimal interface, 2) deep if it was within the plaque with 2:0.3 mm of overlying noncalcified plaque, or 3) both (Fig.

Quantitative ultrasound. The circumference of athero­sclerotic plaque in the target iesion occupied by calcium was measured as an arc (in 0) with a protractor centered on the imaging catheter (Fig. 2). The target lesion was identified by using a fluoroscopic reference for the ultrasound catheter position to ensure accurate comparison with angiographic data. If there was more than one calcific deposit in a given imaging slice, the arcs of calcium were added. If the arcs overlapped, they were measured as a single continuous arc.

MINTZ ET AL. 1151 JACe Vol. 20, No.5 November I, 1992:1149-55 TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

Figure 2. Intravascular ultrasound images from four patients, illus­trating the measurement of the circumferential arc of calcium. A, Noncalcified artery. B, Fibrotic-calcific atherosclerotic plaque with an arc (arrows) of calcium measuring 74° (note the shadowing of the deeper tissues beyond the calcium). C, Artery with an arc of calcium measuring 271°. D, Complete (360°) circumferential intimal calcifi­cation.

With the motorized pullback device, the length of each calcific deposit or the overall length of contiguous and overlapping calcific deposits was measured in 40 patients. With the imaging catheter moving at 0.5 mm/s, each second of recorded videotape represents a segment of artery 0.5 mrn long. Two contiguous imaging slices are 17 ,urn apart. For the purposes of this study, the length of a calcified arterial segment was calculated from the number of seconds or the number of frames of videotape in which it appeared (Fig. 3 and

With three-dimensional reconstruction, the area of inti­mal surface occupied by calcification could be visualized. When visualizing the artery from outside the adventitia, adventitial dropout represented underlying calcification (Fig. 5). Confirmation that adventitial dropout was caused by underlying calcification (rather than by weak acoustic pene-

Figure 3. Intravascular ultrasound images of a short calcific deposit (shown by open arrows) that is circumferential in the second image slice and 1O{)0 in the third image slice. The study was performed with the motorized pullback device. Image slices shown are I mm apart at center; the most distal slice is at left, and the most proximal slice is at right. The calcific deposit occupies <2 mm of axial vessel length. No calcium was detected on fluoroscopic study.

tration) was confirmed by relating the three-dimensional reconstruction to the corresponding two-dimensional image slices.

Statistical analysis. Statistical was performed by using chi-square analysis, the Student test, the Fisher exact test, analysis of variance or correlation coefficients where appropriate. Results are reported as mean value ± 1 SD.

Results Fluoroscopic analysis. By fluoroscopy, 50 patients (48%)

had calcification in the region of the target lesion treated by transcatheter therapy.

Intravascular ultrasound analysis. By intravascular ultra­sound, 84 patients (76%) had target lesion calcification (p < 0.001 vs. the number detected with fluoroscopy). Forty­seven patients (56%) had a single calcific deposit; the other 37 had two or more calcific deposits. In these 84 patients the arc of calcium measured 100 ± (range 00 to 360°); in 29 patients it measured ~90°, in 25 patients 91° to 180°, in 17 patients 181° to 270° and in 13 patients 271 0 to 3600 (Fig. 6). In 42 patients (50%) the calcification was superficial, in 13 (15%) it was deep and in 31 (35%) it was both superficial and deep.

In 40 patients the longitudinal length of single or mUltiple contiguous calcific deposits could be measured. Twenty-nine of these patients (73%) had target lesion calcification. The mean length was 15 ± 9 mm (range to 40). In 11 patients, the length was :55 mm, in 6 it was 6 to 10 mm, in 7 it was 11 to 20 mm and in 5 it was >20 mm. In these 29 patients there was no significant correlation between the arcs and length of target lesion calcification (Fig. 7).

Typically, there was significant axial variability in the circumferential arc of calcification within each lesion site (Fig. 8 and 9).

Clinical correlates (Table Target lesion calcium did not correlate with patient age, duration of angina or a history of hypertension, diabetes or a remote myocardial infarction. Calcification was more common in smokers (37 of 38) than in nonsmokers (49 of72, p < 0.001) and the arc of calcium was larger in smokers than in nonsmokers (157 ± 1260

VS. 83 ± 91°, p < 0.02). Calcification tended to be more common in

1152 MINTZ ET AL. TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

lAce Vol. 20, No.5 November 1, 1992:1149-55

Figure 4. Intravascular ultrasound images of a long, circumferential calcium deposit (arrows). Image slices shown are 5 mm apart at center; the most distal slice is at left and the most proximal slice is at right. The uninterrupted calcific deposit occupies 40 mm of axial vessel length. Extensive calcium was evident on fluoroscopic study.

patients with multivessel or left main disease (53 of 61) than in patients with single-vessel disease (35 of 49, p = 0.060) and the arc of calcification tended to be larger in the former

Figure 5. Three-dimensional reconstruction of intravascular ultra­sound images, showing the circumferential and the axial distribution of calcium. The artery is shown as two hemicylinders and is viewed from outside so that only the outermost layer (or adventitia) is seen normally. A and F show hemicylinders, 20 mm long. Adventitial dropout (short thin arrows) represents acoustic shadowing from underlying calcification. The axial length of the largest calcium deposit is from point G to point H. Panels D, C, D and E are two-dimensional image slices from this artery. The calcium in these two-dimensional image slices is shown by the open arrows. The long arrows locate these image slices within the axial length of the artery shown in F.

groups (137 ± 1180 vs. 81 ± 79°, p < Similarly, target lesion calcification tended to be more common in patients with than in those without previous coronary artery bypass graft surgery of 18 vs. 70 of 92, p =: and the arc of calcification tended to be larger in group (137 ± 1180 vs. 81 ± 79°, p < 0.05). There were too few patients with insulin-dependent diabetes mellitus or chronic renal insuffi­ciency for statistical analysis. Target lesion calcification did not correlate with the angiographic percent diameter steno­sis before intervention or with lesion location or morphol­ogy.

Fluoroscopic-ultrasound correlations. Fluoroscopic target lesion calcification was more common in patients whose arc of calcification measured ;;::910 (36 (74%] of 51) than in patients whose arc measured ::;90 (10 [29%] of 33, p < 0.001).

In 40 patients, both the arc and the length of calcification could be measured. When both of these variables were considered, calcium was detected fluoroscopy in no patient with an arc ::;900 and a length ::;5 mm, 0 of 5 patients with an arc 91° to 3600 and a length ::;5 mm, 2 of 3 patients with an arc ::;900 and a length ;;::6 mm and 13 (86%) of 15 of patients with an arc 91° to 3600 and a length ;;::6 mm.

Three-dimensional reconstruction of ultrasound image slices. Intimal surface (plaque) calcification was not obvi­ously different from a noncalcified intimal surface, and deeper tissue calcification was not seen at all. However, when viewed from outside the artery (Fig. 5), adventitial dropout accurately reflected underlying superficial and deep

Figure 6. Distribution of target lesion calcification according to the number of quadrants involved. Twenty-four percent of 110 patients had no calcification, 26% had calcification of one quadrant, 23% of two quadrants, 15% of three quadrants and 12% of four quadrants.

N=110 patients

26%

1-90 91·180 1111-270 271·360

Arc of Target Lesion Calcium (degrees)

lACC Vol. 20, No.5 MINTZ ET AL. 1153 ;>.lovember 1992:1149-55 TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

~36°1 ~

~270 ~

. . . l O+---~~--~~--~--~--~~

o 5 U U • ~ ~ 9 ~

Length of Target Lesion Calcium (mm)

Figure 7. There is no correlation between the circumferential arc of target lesion calcification and its axial length.

plaque calcification in all patients. Small and large calcific deposits were seen equally well. Contiguous calcium depos­its appeared as a single large deposit unless they were separated by 1 mm of uncalcified artery. Circumferential calcification as short as 1 mm appeared as "napkin-ring" adventitial dropout. Long, single-quadrant calcification ap­peared as a linear streak of adventitial dropout.

Discussion Lesion-associated calcification is found frequently at nec­

ropsy in patients with coronary atherosclerosis (12,13). These studies have shown that coronary artery calcification increases with the extent and severity of atherosclerosis (14), patient age (15,16) and primary or secondary chronic hypercalcemia (17). In addition, both hyperlipidemias (18,19) and chronic renal failure (20) may predispose to coronary artery calcification, the former by accelerating atherogenesis and the latter by causing chronic hypercalce­mia. The highest pathologic incidence reported is 79% (4). However, pathologic detection has limitations. Patient se­lection is biased and specimens usually are decalcified before staining. In vitro X-ray analysis of pathologic tissue has limited resolution and is only semiquantitative. With the motorized pullback device, it is possible to slice the artery into more and thinner slices with intravascular ultrasound than is commonly done during pathologic analyses.

High frequency intravascular ultrasound provides de­tailed transmural images of human coronary arteries in vivo

Figure 8. Variability in circumferen­tial arc of target lesion calcification even within a short « 1 arterial segment. Image slices shown are 0.1 mm apart at center; the most distal slice is at left, and the most proximal slice is at right. Arrows point to calcific deposits in some of the image slices.

(8-1 The normal coronary artery architecture (intima, media and adventitia) and the major components of the atherosclerotic plaque loose and dense fibrous con­nective tissue, intimal hyperplasia and calcium) can be studied in vivo in a manner not possible previously.

In previous studies, the acoustic signature of arterial plaque calcium, dense fibrous tissue and soft plaque (con­taining lipid, loose connective tissue or intimal hyperplasia) has been validated in vitro. Using intravascular ultrasound imaging, we detected calcium in 84 (76%) of 110 lesions targeted for transcatheter therapy. This proportion approx­imates the highest pathologic incidence reported.

Calcification can be superficial or deep and occur in single or multiple discrete deposits. However, circumferential dep­osition of calcification tends to be greater than axial deposi­tion. Short arterial segments with extensive (multi quadrant) circumferential calcification are more common than are long segments with single-quadrant calcification.

Within any length of calcified artery, there can be exten­sive axial variability in the pattern of calcium deposition. Axial variability tends to be more pronounced than circum­ferential variability and is greater in heavily calcified than in lightly calcified arteries. Both very short calcified segments and the marked axial variability in calcium deposition are seen best with slow movement of the transducer and careful interrogation of the entire artery, which can be facilitated by motorized transducer movement. Furthermore, intravascu­lar ultrasound imaging can differentiate target lesion calcifi­cation from calcification of contiguous arterial segments.

Many studies have used X-ray techniques to detect coronary artery calcification to screen for hemodynamically significant coronary artery disease. A meta-analysis of 13 reports (21) suggested that 58% of patients with documented coronary artery disease have fluoroscopic calcification. This frequency may be increased by using digital subtraction fluoroscopy (22), computed tomography (22-24) and ultra­fast computed tomography (25,26). In our study, there was fluoroscopic calcification in 48% of lesions targeted for transcatheter therapy. With use of intravascular ultrasound imaging as the standard, fluoroscopic calcification increased with increasing amounts of target lesion calcification. Fluo­roscopy detected calcium in 74% of patients with multiquad­rant target lesion calcification and in 86% of patients with

1154 MINTZ ET AL. TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

JACC Vo\. 20, No.5 November I, 1992:1149-55

a 360 .E! ~ ';'270

d ~ 180 ... u e ..

u 'C 901~===:::~====~ ~ ...... o

A -10 -8 "' -4 ·1 0 1 4 6 8 10

Distance from Center of Lesion (mm)

a ~{ll~ii~~~~lIliliii!l~~ .E! .!: 'iii"170 .. =- ~ .. ~ ~180 . e.. .

'C 90 . ~ ......

o

B .10·8·6 -4 ·1 0 1 4 6 8 10

Distance from Center of Lesion (mm)

~ 360

3!'iii"170~... I!iY <IS ..

~ ~180· e .. u'C 90 ~ ......

o

C -10·8", -4 .1 0 1 4 6 8 10

Distance from Center of Lesion (mm)

~ 360

:g ';'270

<IS.. t~~~~~~~~~~~~;7 ~ ~180 e .. u'C 90 ~ ......

o

D -10 -8 "' -4 ·1 0 1 4 6 8 10

Distance from Center of Lesion (mm)

Figure 9. Graphs illustrating the variability in arc of calcium within any given target lesion length. The arc of calcification is shown on the y axis; the target lesion length is shown on the x axis as the distance from the center of the lesion with the most distal end of the lesion in negative numbers at left. Individual patients are shown on the z axis. A, Four patients with calcification of one quadrant. B, Nine patients with calcification of two quadrants. C, Seven patients with calcification of three quadrants. D, Nine patients with calcifi­cation of four quadrants. The center of the lesion was the longitu­dinal middle of the most severe length of stenosis (as determined by intravascular ultrasound imaging using the motorized pullback de­vice).

Table 1. Clinical Correlates in the Study Group

Calcium Arc of (no. of Calcium (")

patients) (mean ± SD)

Smoking Yes 370f38

} <0.001 157 ± 126 } <0.02 No 49 of 72 83 ± 91

Hypertension Yes 48 of 63

} NS 95 ± 107 } NS No 39 of 47 100 ± 97

Remote MI Yes 30 of 38

} NS 119 ± lOS

} NS No 58 of 72 194 ± 106

CABG Yes 17 of 18 } 0.076

194 ± 106 } <0.01 No 70 of 92 100 ± 98

CAD I-V 35 of 49 } 0.060

81 ± 79 } <0.05 2-V/3-VILM 53 of 61 137 ± 118

LAD 36 of 47 } NS

93 ± 110 } LCx 16 of 18 lOS ± 76 NS RCA 270f38 86 ± 91

Values outside braces indicate p values. CABG = coronary artery bypass graft surgery; CAD = coronary artery disease; LAD = left anterior descend-ing coronary artery; LCx = left circumflex coronary artery; LM = left main coronary artery; MI = myocardial infarction; RCA = right coronary artery; V = vessel.

long multi quadrant calcification and a length ~6-mm. How­ever, fluoroscopy missed all examples of short multiquad­rant calcification with a length <5 mm.

Limitations. Our study has several limitations. 1. On pathologic study, calcific deposits have width,

length and thickness. Because of acoustic shadowing arti­facts, our method may minimize the true amount of calcium present. Most often, ultrasound studies were performed after transcatheter therapy, and some trans catheter thera­pies (for example, rotational atherectomy) remove calcium. Thus, calcification may be even more common and more extensive than our data suggest.

2. From the standpoint of impact on transcatheter ther­apy, the most important measurement may be the intimal surface area occupied by calcium. By measuring the intimal arc and axial length of calcium, we can approximate its surface area. Current algorithms for three-dimensional re­construction of intravascular ultrasound images do not per­mit a true measurement of the intimal surface occupied by calcium. However, the surface area of adventitial dropout does reflect the surface area of underlying plaque calcifica­tion. Also, it is not possible to measure the thickness of the calcific deposits; the inner edge shadows the outer edge. Similarly, superficial plaque calcification obscures deep plaque calcification. Calcification thickness may also play an important role in arterial responses to transcatheter therapy.

MINTZ ET AL. 1155 JACC Vol. 20, No.5 November I, 1992:1149-55 TARGET LESION CALCIFICATION IN CORONARY ARTERY DISEASE

3. Few of our patients had chronic total occlusions. The plaque composition in such patients may differ from that of our study group. Plaque calcification in chronic total occlu­sions is important if a truly effective transcatheter therapy is to be developed, especially if this therapy is based on laser technology.

4. Our observations are limited to native vessel target lesion morphology in symptomatic patients. We did not image nontarget lesion vessels or vessels in asymptomatic patients. We have not included data on saphenous vein bypass grafts, and we also excluded patients with an acute infarction.

5. With current imaging systems, all plaque calcium looks alike. Calcium may be incorporated into atherosclerotic plaque in more than one way; the way it is incorporated may influence the structural integrity of the plaque and the arterial response to transcatheter therapy (27).

6. We did not attempt to relate procedural success to the amount or distribution of target lesion and adjacent vessel calcification. This important study needs to be done.

Implications. Calcification is a major determinant in how target lesions respond to various transcatheter therapies. Recently developed low profile imaging catheters (such as the 3.9F catheter used in 40 of our studies) makes imaging feasible before intervention. As more trans catheter therapies become available, it may become important to use intravas­cular ultrasound to analyze target lesion composition to select among them.

References I. Potkin BN, Mintz GS, Matar FA, et aI. A mechanistic comparison of

transcatheter therapies assessed by intravascular ultrasound (abstr). Circulation 1991;84(suppl I1):II·541.

2. Potkin BN, Mintz GS, Keren G, Douek PC, Matar FA, Satler LF. Ultrasound assessment of lesion composition predicts mechanisms of PTCA (abstr). Circulation 1991;84(suppl I1):II·722.

3. Fitzgerald PJ, Sudhir K, Sykes CM, Ports TA, Strunk BL, Yock PG. Localized calcium is a major risk factor for arterial dissection during angioplasty: a catheter ultrasound study (abstr). Circulation 1991 ;84(suppl II):II·722.

4. Robertson GC, Horihara T, Selmon MR, Johnson DE, Simpson JB. Directional coronary atherectomy. In: Topol EJ, ed. Textbook of Inter· ventional Cardiology. Philadelphia: WB Saunders, 1990:563-79.

5. Matar FA, Mintz GS, Potkin BN, et aI. Ultrasound plaque composition determines directional coronary atherectomy effect (abstr). Circulation 1991;84(suppl II):II·154.

6. Bertrand ME, Fourrier JL, Auth DC, Lablanche JM, Gommeaux AF. Percutaneous coronary rotational angioplasty. In: Ref 4:580-9.

7. Isner JM. Pathology in cardiovascular laser therapy. In: Isner MJ, Clarke RH, eds. Cardiovascular Laser Therapy. New York: Raven, 1989:63-87.

8. Tobis JM, Mallery JA, Gessert J, et al. Intravascular ultrasound cross­sectional arterial imaging before and after balloon angioplasty in vitro. Circulation 1989;80:873-82.

9. Potkin BN, Bartorelli AL, Gessert JM, et aI. Coronary artery imaging with intravascular high-frequency ultrasound. Circulation 1990;81:1575-85.

10. Nishimura RA, Edwards WD, Warnes CA, et al. Intravascular ultrasound imaging. In vitro validation and pathologic correlation. J Am Coli Cardiol 1990;16:145-54.

11. Gussenhoven EJ, Essed CE, Lancee CT, et aI. Arterial wall characteris­tics determined by intravascular ultrasound imaging. An in vitro study. J Am Coli CardioI1989;14:947-52.

12. Blankenhorn DH. Coronary arterial calcification. A review. Am J Med Sci 1961;242:4-49.

13. Warburten RK, Tampas JP, Soule AB, Taylor HE III. Coronary artery calcification: its relationship to coronary artery stenosis and myocardial infarction. Radiology 1968;91:109-15.

14. Frink RJ, Achor RWP, Braun AL Jr, Kincaid OW, Brandenburg RO. Significance of calcification of the coronary arteries. Am J Cardiol 1970;26:241-7.

15. Waller BF, Roberts WC. Cardiovascular disease in the very elderly. Analysis of 40 necropsy patients aged 90 years or over. Am J Cardiol 1983;51:403-21.

16. Gertz SD, Malekzadeh S, Dollar AL, Kragel AH, Roberts WC. Compo­sition of atherosclerotic plaques in the four major epicardial coronary arteries in patients ~90 years of age. Am J Cardioll99I;67:1228-33.

17. Roberts WC, Waller BF. Effect of chronic hypercalcemia on the heart. Am J Med 1981;71:371-84.

18. Sprecher DL, Schaefer EJ, Kent KM, et al. Cardiovascular features of homozygous familial hypercholesterolemia: analysis of 16 patients. Am J CardioI1984;54:20-30.

19. Dinsmore RE, Lees RJ. Vascular calcification in types II and IV hyper­Iipoproteinemia: radiographic appearance and clinical significance. Am J Roentgenoll985;144:895-9.

20. Meema HE, Oreopoulos 00, deVeber GA. Arterial calcifications in severe chronic renal disease and their relationship to dialysis treatment, renal transplant, and parathyroidectomy. Radiology 1976;121:315-21.

21. Gianrossi R, Detrano R, Colombo A, Froelicher V. Cardiac fluoroscopy for the diagnosis of coronary artery disease: a meta analytic review. Am Heart J 1990;120:1179-88.

22. Detrano R, Markovic D, Simpfendorfer C, et al. Digital subtraction fluoroscopy: a new method of detecting coronary calcification with improved sensitivity for the prediction of coronary disease. Circulation 1985;71:725-32.

23. Moore EH, Greenberg RW, Merrick SH, Miller SW, McCloud TC, Shepard 10. Coronary artery calcification: significance of incidental detection on CT scans. Radiology 1989;172:711-6.

24. Masuda Y, Naito S, Aoyagi Y, et al. Coronary artery calcification detected by CT: clinical significance and angiographic correlates. Angi­ology 1990;41:1037-47.

25. Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamante M Jr, Detrano R. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coli Cardioll990;15:827-32.

26. Tanenbaum SR, Kondos GT, Veselik KE, Prendergast MR, Brundage BH, Chanka EV. Detection of calcific deposits in coronary arteries by ultrafast computed tomography and correlation with angiography. Am J CardioI1989;63:870-2.

27. Foreman DW, Mitchell JC, Baker PB. Physical chemical evidence of structural weakness in coronary arterial calcification. Cardiovasc Res 1989;23:64-9.