TALL BUILDING DRAFT DESIGN

24
Joan Tresserras Pujol-Xicoy TALL BUILDING DRAFT DESIGN

description

TALL BUILDING DRAFT DESIGN. Joan Tresserras Pujol- Xicoy. 1. Section dimensions. Columns : 1 – 5 floors :. 1. Section dimensions. 5 – 10 floors : 11 – 15 floors : 16 – 20 floors : 21 – 25 floors : 26 – 30 floors : 31 – 35 floors :. 1. Section dimensions. Beams : - PowerPoint PPT Presentation

Transcript of TALL BUILDING DRAFT DESIGN

Page 1: TALL  BUILDING DRAFT DESIGN

Joan Tresserras Pujol-Xicoy

TALL BUILDINGDRAFT DESIGN

Page 2: TALL  BUILDING DRAFT DESIGN

Columns:• 1 – 5 floors:

1. Section dimensions

Page 3: TALL  BUILDING DRAFT DESIGN

• 5 – 10 floors:

• 11 – 15 floors:

• 16 – 20 floors:

• 21 – 25 floors:

• 26 – 30 floors:

• 31 – 35 floors:

1. Section dimensions

Page 4: TALL  BUILDING DRAFT DESIGN

Beams:

Slabs:

1. Section dimensions

Page 5: TALL  BUILDING DRAFT DESIGN

2. Design requirements

Page 6: TALL  BUILDING DRAFT DESIGN

2. Design requirements

Page 7: TALL  BUILDING DRAFT DESIGN

Wind loading:• According to the chinese code:

• Return period of 50 years Wp = 0,55KN/m2.

• Return period of 100 years Wp = 0,60KN/m2

• Building situated in Tianjin, China Roughness type C

• When using the program we choose the Chinese 2002 code

3. Loading

Page 8: TALL  BUILDING DRAFT DESIGN

Earthquake loading:• Design with a basic fortification intensity of 7.• In consequence a ground acceleration of 0,15g is

used.

• Site classification is a site-class IV.

• When using the program we choose the Chinese 2002 code.

3. Loading

Page 9: TALL  BUILDING DRAFT DESIGN

Dead load:

• Automatically calculated the program (Self Weight Multiplier = 1).

• It is necessary to add dead load to the slabs inside the shear wall areas, due to their very small thickness. These slabs help to transfer lateral stresses.

• Add a dead load = 7,5kN/

3. Loading

Page 10: TALL  BUILDING DRAFT DESIGN

Live load:• Following the chinese code:

3. Loading

Page 11: TALL  BUILDING DRAFT DESIGN

• Basically, the material used will be concrete. Default concrete given by ETABS is a C40 concrete. For structural reasons a new concrete C60 will be created.

• Steel only used in the reinforcement bars.

4. Materials

Page 12: TALL  BUILDING DRAFT DESIGN

• A 3-D grid with all the elevation and plan dimensions inputed has to be created.

5. Model elaboration

Page 13: TALL  BUILDING DRAFT DESIGN

• It is convenient to create a new set of columns every 5 stories to make it easy when dimensioning them.

• In the first 4 floors the columns that don’t have floors on top will also be different than the ones with 35 floors on top

5. Model elaboration

Page 14: TALL  BUILDING DRAFT DESIGN

• When drawing shear walls it’s possible to distinguish into two kinds of shear walls:

• The ones surrounding the elevators and stairs.

• In the residential floors, the ones dividing the different apartments.

5. Model elaboration

Page 15: TALL  BUILDING DRAFT DESIGN

• There are two kinds of beams:• Primary beams that go from column to column. The

moment release for this kind of beams will be continuous.

• Secundary beams that go from beam to beam. The chosen distribution for this type of beams is a cross distribution. The moment release for this kind of beams will be pinned.

• No beams should be drawn inside the shear walls.

5. Model elaboration

Page 16: TALL  BUILDING DRAFT DESIGN
Page 17: TALL  BUILDING DRAFT DESIGN

• Two kinds of slabs: 1.Normal slabs ; 2.Inside shear walls slabs

5. Model elaboration

Page 18: TALL  BUILDING DRAFT DESIGN
Page 19: TALL  BUILDING DRAFT DESIGN

• Three requirements should be met by the model:• First rotation period / x or y period < 0,9• Story drift < 1/800• Maximum story drift / average story drift < 1,4

• To meet this three requirements a process of analysis and later dimensioning of the structural members will take place.

• It will be necessary to look at the different modes of structure to determine which one is the first to have rotation.

6. Model analysis

Page 20: TALL  BUILDING DRAFT DESIGN

6. Model analysis

1st mode 2nd mode 3rd mode

Page 21: TALL  BUILDING DRAFT DESIGN

6. Model analysis

Deformed shape 3-D View Longitudinal Reinforcing

Page 22: TALL  BUILDING DRAFT DESIGN

6. Model analysis

Page 23: TALL  BUILDING DRAFT DESIGN

First rotation period / x or y period < 0,9The first rotation period is the one of the third mode = 1,85398The first period with x or y movement is the first mode = 2,50081

1,85398 / 2,50081 = 0,741352 < 0,9 Story drift < 1/800

The maximum story drift is for the 35th floor:

1/811 < 1/800 Maximum story drift / average story drift < 1,4

The maximum story drift is for the 1st floor= 1/811

Average story drift = 9,5992*10^(-4)

(1/811) / ( 9,5992*10^(-4)) = 1,285 < 1,4

7. Requirements

Page 24: TALL  BUILDING DRAFT DESIGN

THANK YOU!谢谢 !