www.ecopower.com Regular Series V2.1UL 27 Oct 2010
1
EcoLight ®
T5 (Retrofit Kit)
User’s Manual (Regular Series)
UL and ULc Listed Models: FSA, FSI, FAU and FAH Series
It is suggested to read this installation manual and follow instructions prior to installation. Incorrect installation and misuse may render the warranty invalid.
EcoPower Electric Ltd Address: Room 1801, Wing On Central Building, 26 Des Voeux Road Central, Central, Hong Kong Tel: (852) 2961 4244 Fax: (852) 3186 3430 Email : [email protected] Website: www.ecopower.com
2-foot, 3-foot, 4-foot and 5-foot complete unit
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
2
Contents
Product Checklist…………………...………………………….….……………………..……….P2
Introduction………………………… ……………………………...…….……………………….P3
Product Dimension….………………….……………………………….………………………….P4
Notices……………………………….……………………..……………………………………….P5
Prior to Installation……….…………………..………………………….………………………….P5
Installation for fittings with Rapid Start / Trigger Start Ballast (Single Lamp)…………………P6
Installation for fittings with Rapid Start / Trigger Start Ballast (Double Lamp)……………….P7
Installation for fittings with Instant Start Ballast (Single Lamp)…………………………………P8
Installation for fittings with Instant Start Ballast (Double Lamp)…………………………….P9
Installation for fittings with Electromagnetic Ballast (Single Lamp)…...………...............….P10
Installation for fittings with Electronic Ballast (Single Lamp)………………………………….P11
Installation for fittings with Electronic Ballast (Single Lamp)………………………………….P12
Instructions of grounding………………...…………………….….…………….……..……….P13
Circuit Diagram and Models with UL and ULc listed……….….……………………..……….P14
Important Notices...………………………………………….…….……………………..……….P15
Product Checklist:
Please remember that the EcoLight T5 retrofit kit, FSA, FSI, FAU and FAH Series, will come with the following contents:
1) 1 x Complete set of retrofit kit, including the lamp adapter.
2) 1 x Starter Plug (Provided for exiting fixture with Electromagnetic Ballast and Starter).
3) 1 x Warning label.
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
3
Introduction: EcoLight® T5 (Retrofit Kit) is a new technology incorporating a T5 electronic ballast in a unique aluminium adapter designed to retrofit an existing T12 or T8 fluorescent system (Fixtures/fittings/luminaries) to achieve energy savings rate of up to 50%. EcoLight® T5 (Retrofit Kit / Retrofit Fixture / Conversion Kit / Adaptor) is designed to provide a cost-effective solution to upgrade conventional luminaries to the very latest T5 system performance. The EcoLight® T5 is compatible with T8, T9, T10 and T12 fluorescent lamp technology and provides numerous immediate and lasting benefits that include: energy savings, a short payback period, simple installation, enhanced light quality, improved eye protection, and a high power factor. EcoLight® T5 is designed so that the investment required to convert a lighting system to state-of-the-art T5 technology is very modest. By using the “LUMINAIRE IN LUMINAIRE” concept, installation is greatly simplified. The patented fixture design is created by mounting a standard T5 fluorescent tube on a slim aluminium housing to form a complete integrated easily installed lighting unit. No starter is required and installation of the T5 retrofit fixture is almost as easy as replacing a fluorescent tube. EcoLight® T5 products which incorporate standard end-cap connectors can be simply and quickly installed into existing fixtures without disrupting the existing ceiling system. The unique design of these end-caps, which can be easily rotated, makes the product easy to adapt to all existing luminaries irrespective of the desired final wall-mounting angle. The adapter is available with without a reflector making it suitable for most applications. EcoLight® T5 is one of the most innovative energy saving devices available to lighting industry designers and suppliers. By utilizing proven PFC and SMT technology, robust electronic components and incorporating the best of current electronic ballast technology, the EcoLight® T5 has been widely utilized to retrofit existing Fluorescent Tube Lamp (FTL) Fixtures/fittings/luminaries. EcoLight® T5 is designed with the protection of both the environment and people in mind. It saves up to 50% of the energy required at a given light output, and obviates the needless disposal of the existing luminaires. Furthermore, the high operating frequency of up to 35,000 Hz incorporated in the EcoLight® T5 design provides enhanced eye protection by eliminating the flickering associated with older lighting systems. EcoLight® T5 can also be used for new installations as a standard T5 luminaire by incorporating several additional components necessary for freestanding operation. EcoPower provides a full range of T5 Retrofit Kit products incorporating several different ballast types. EcoLight® T5 products are designed to meet today’s demanding market requirements. Please refer to the detailed specifications sheet for additional product details. FSA, FSI, FAU and FAH Series comply with UL and cUL.
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
4
Product Dimension:
Standard T5 Fluorescent Lamp
***
***Aluminium housing (Option: With or without reflector)
Note: The unique G13 and R17d rotatable End-Cap makes the product suitable
for all existing luminaries whatever the lamp-holder mounting angle.
Before rotating the G13 and R17d, the grub screw must be loosened
anti-clockwise about 1/4 turn. After rotating the cap to the required position, the
grub screw must be tightened by turning clockwise.
600mm/900mm/1200mm/1500mm
549mm/849mm/1149m/1449mm
35mm
23mm
35mm
21.5mm
The rotatable End-Cap which can fit tube from T8 to T12
Aluminium Reflector with 120 ˚ angle of reflection. Total viewable angle is
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
5
Notices: 1) EcoLight® T5 (Retrofit Kit) is used together with standard T5 fluorescent lamp. 2) The product can be retrofit into existing luminaires with different ballast. Alternatively, the fixture can be
operated as it is supplied utilizing the built-in T5 electronic ballast to run the lamp independently. 3) Simple wiring changes are required to bypass the existing ballast. Please follow the instructions from
page 6 to page 12 in this manual. 4) The ballast and wires inside the kit are built with double-insulation, but grounding of the fixture may be
required in some regions. Check with local code requirements. 5) The lifetime of the unit will be reduced under high temperature operation. Please be reminded the
EcoLight® T5 products should be installed in environments with good ventilation. Suppliers are not responsible for any defect of the EcoLight® T5 products caused by operating the unit outside the recommended working temperature range of -15℃~ +50℃.
6) Please do not remove fluorescent lamp while the power to the fixture is switched on. 7) The products (FSA, FSI, FAU and FAH series) are “Not for use with dimmers” or “Not for use in
Luminaries controlled by a dimmer”. 8) CAUTION – Risk of Electric Shock – Use in Dry Locations Only. 9) The products (FSA, FSI, FAU and FAH series) are not intended for use with emergency exit luminaires
or emergency exit lights. 10) The products (Regular Series) are intended to be installed in a Listed T8-T12 open or enclosed
fluorescent surface or recessed (Type Non-IC) luminaire with a maximum 4 lamp configuration in 2-foot, 3-foot, 5-foot and 4-foot length.
11) WARNING –The luminaire has been modified to accommodate EcoLight T5 retrofit kit. DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has been carried out by a licensed electrician. IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
12) The retrofit kits require both line and neutral power to be connected to the same lampholder. 13) Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. 14) Please contact us if there are any questions regarding the use and proper installation of this product. Prior to Installation: 1. Remove the EcoLight® T5 products carefully from the packaging and check that the products supplied
are identical to those listed on the delivery invoice and the purchase order; Check the products supplied are compatible with the existing fluorescent lamps and luminaires.
2. Check that the Voltage ratings of the products are identical to those of the existing system.
3. Check to ensure that there are no loose or damaged parts resulting from shipping the product(s).
4. Simple wiring changes are required to bypass the existing ballast. Please follow the instructions from page 6 to page 9 of this manual.
5. Note that the EcoLight® T5 products can operate without any ballast inside the existing fixture(s). This means that all existing ballast(s) (Including the electromagnetic ballast) can be either removed completely or simply bypassed.
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
6
Installation for fittings with Rapid Start / Trigger Start Ballast (Single Lamp):
Procedure: 1) Install the unit by qualified persons. 2) Disconnect the power of existing lamp. 3) Remove the existing lamp.
4) Complete the changes outlined in # Wiring 1. 5) Unused leads must be capped off. 6) Fix the standard T5 tube to EcoLight® T5 Retrofit. 7) Connect the grounding wire to the earth sign “⏚” on the underside of the luminaire. 8) Reinstall the complete unit into the existing rewired luminaire. 9) Ensure the complete unit is installed firmly. 10) Reconnect the power and installation is complete. 11) Check that the unit operates correctly. 12) Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 1: 1. Disconnect the BLUE wires from the
ballast and connect to the LINE by using the wire connector. See below.
2. Make sure the polarity of LINE match with the T5 end-cap.
3 The LIVE (L) of retrofit is always wired to right metal pin.
4 The RED wires connecting to the dummy lampholder can be removed.
5 Any leads must be capped.
LINE (LIVE & NEUTRAL)
LINE (LIVE & NEUTRAL) Connection Diagram before installation
WHITE BLACK
Fluorescent Lamp
Rapid Start /Trigger Start Ballast
RED RED
BLUE BLUE
Connection Diagram after installation
The Ballast is bypassed!
WHITE BLACK
T5 End Cap (G13)
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
7
Installation for fittings with Rapid Start / Trigger Start Ballast (Double Lamp):
Procedure: 1. Install the unit by qualified persons. 2. Disconnect the power of existing lamp. 3. Remove the existing lamps. 4. Complete the changes outlined in # Wiring 2. 5. Unused leads must be capped off. 6. Fix the standard T5 tube to EcoLight® T5 Retrofit. 7. Connect the grounding wire to the earth sign “ ” on the underside of the ⏚ luminaire. 8. Reinstall the complete unit into the existing rewired luminaire. 9. Ensure the complete unit is installed firmly. 10. Reconnect the power and installation is complete. 11. Check that the unit operates correctly. 12. Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 2: 3. Disconnect the YELLOW wires from
the ballast and connect to the LINE by using the wire connector. See below.
4. Make sure the polarity of LINE match with the T5 end-cap.
5. The LIVE (L) of retrofit is always wired to right metal pin.
6 The RED and Blue wires connecting to the dummy lampholder can be removed or disconnected.
7 Any leads must be capped.
T5 End Cap (G13)
Connection Diagram before installation
LINE (LIVE & NEUTRAL) Connection Diagram before installation
WHITE BLACK
Fluorescent Lamp
Rapid Start / Trigger Start Ballast BLUE
BLUE
Fluorescent Lamp
RED RED
LINE (LIVE & NEUTRAL)
WHITE BLACKThe Ballast is
bypassed!
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
8
Installation for fittings with Instant Start Ballast (Single Lamp):
Note: The retrofit kit cannot be installed in luminaires employing shunted bi-pin lampholders. Procedure: 1 Install the unit by qualified persons. 2 Disconnect the power of existing lamp. 3 Remove the existing lamp.
4 Complete the changes outlined in # Wiring 3. 5 Unused leads must be capped off. 6 Fix the standard T5 tube to EcoLight® T5 Retrofit. 7 Connect the grounding wire to the earth sign “⏚” on the underside of the luminaire. 8 Reinstall the complete unit into the existing rewired luminaire. 9 Ensure the complete unit is installed firmly. 10 Reconnect the power and installation is complete. 11 Check that the unit operates correctly. 12 Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 3: 1 Disconnect the WHITE wires from the
ballast and connect to the LINE by using the wire connector. See below.
2 Make sure the polarity of LINE match with the T5 end-cap.
3 The LIVE (L) of retrofit is always wired to right metal pin.
4 The BLUE wires connecting to the dummy lampholder can be removed or disconnected.
5 Any leads must be capped.
LINE (L & N) The Instant Start Ballast is bypassed!
Connection Diagram after installation
LINE
Connection Diagram before installation
Fluorescent Lamp
Instant Start BallastBLUEWHITE
WHITE
T5 End Cap (G13)
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
9
Installation for fittings with Instant Start Ballast (Double Lamp):
Note: The retrofit kit cannot be installed in luminaires employing shunted bi-pin lampholders. Procedure: 1 Install the unit by qualified persons. 2 Disconnect the power of existing lamp. 3 Remove the existing lamps. 4 Complete the changes outlined in # Wiring 4. 5 Unused leads must be capped off. 6 Fix the standard T5 tube to EcoLight® T5 Retrofit. 7 Connect the grounding wire to the earth sign “ ” on the underside of the ⏚ luminaire. 8 Reinstall the complete unit into the existing rewired luminaire. 9 Ensure the complete unit is installed firmly. 10 Reconnect the power and installation is complete. 11 Check that the unit operates correctly. 12 Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 4: 1 Disconnect the BLACK and WHITE
wires from the ballast and connect to the LINE by using the wire connector. See below.
2 Make sure the polarity of LINE match with the T5 end-cap.
3 The LIVE (L) of retrofit is always wired to right metal pin.
4 The BLUE and RED wires connecting to the dummy lampholder can be removed.
5 Any leads must be capped.
Connection Diagram after installation
Connection Diagram before installation
Fluorescent Lamp
Instant Start BallastWHITE
Fluorescent Lamp
BLACK BLUE
RED
The Instant Start Ballast is bypassed!
LINE
LINE
T5 End Cap (G13)
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
10
Installation for fittings with Electromagnetic Ballast:
Procedure: 1) Install the unit by qualified persons. 2) Disconnect the power of existing lamp. 3) Remove the existing lamp.
4) Remove the existing Starter to form an open-circuit. 5) Remove / by-pass the existing PFC capacitor if there is any. 6) Complete the changes outlined in # Wiring 5. 7) Fix the standard T5 tube to EcoLight® T5 Retrofit Kit. 8) Connect the grounding wire to the earth sign “⏚” under the kit 9) Reinstall the completed unit into the existing kit. 10) Verify that the complete unit is installed firmly in the existing fixture. 11) Fit the Starter Plug to cover the opening of the starter. 12) Reconnect the power and installation is complete. 13) Check that the unit operates correctly 14) Note: The retrofit kits require both live and neutral power to be connected
to the same lampholder. The other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
T5 End Cap (G13)
# Wiring 5: 1) Disconnect the WHITE wires from
the ballast and connect to the LINE by using the wire connector. See below.
2) Make sure the polarity of LINE match with the T5 end-cap.
3) The LIVE (L) of retrofit is always wired to right metal pin.
4) The wires connecting to Starter and the dummy lampholder can be removed or disconnected.
5) Any leads must be capped.
Starter
Connection Diagram before installation LINE (LIVE & NEUTRAL)
Electromagnetic Ballast
T8 ~T12 Tube (Dimension: 600/900/1200 /1500mm)
WHITEBLACK
* The electromagnetic ballast is bypassed by connection Live and Neutral to one end of lamp holder.
** The starter is not required and must be removed! Circuit must be opened in this application.
**
Connection Diagram after installation
* The ballast is by-passed LINE
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
11
Installation for fittings with Electronic Ballast (Single Lamp):
Procedure: 1 Install the unit by qualified persons. 2 Disconnect the power of existing lamp. 3 Remove the existing lamp.
4 Complete the changes outlined in # Wiring 6. 5 Unused leads must be capped off. 6 Fix the standard T5 tube to EcoLight® T5 Retrofit. 7 Connect the grounding wire to the earth sign “⏚” on the underside of the luminaire. 8 Reinstall the complete unit into the existing rewired luminaire. 9 Ensure the complete unit is installed firmly. 10 Reconnect the power and installation is complete. 11 Check that the unit operates correctly. 12 Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 6: 1 Disconnect the BLUE wires from the
ballast and connect to the LINE by using the wire connector. See below.
2 Make sure the polarity of LINE match with the T5 end-cap.
3 The LIVE (L) of retrofit is always wired to right metal pin.
4 The RED wires connecting to the dummy lampholder can be removed.
5 Any leads must be capped.
LINE (LIVE & NEUTRAL)
LINE (LIVE & NEUTRAL) Connection Diagram before installation
WHITE BLACK
Fluorescent Lamp
Electronic Ballast RED RED
BLUE BLUE
Connection Diagram after installation
The Ballast is bypassed!
WHITE BLACK
T5 End Cap (G13)
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
12
Installation for fittings with Electronic Ballast (Double Lamp):
Procedure: 1 Install the unit by qualified persons.
2 Disconnect the power of existing lamp. 3 Remove the existing lamps. 4 Complete the changes outlined in # Wiring 7. 5 Unused leads must be capped off. 6 Fix the standard T5 tube to EcoLight® T5 Retrofit. 7 Connect the grounding wire to the earth sign “ ” on the underside of th⏚ e luminaire. 8 Reinstall the complete unit into the existing rewired luminaire. 9 Ensure the complete unit is installed firmly. 10 Reconnect the power and installation is complete. 11 Check that the unit operates correctly. 12 Note: The retrofit kits require both live and neutral power to be connected to the same lampholder. The
other lampholder will only be a "dummy" or unused lampholder.
Instructions of grounding:
WARNING The luminaire has been modified to accommodate EcoLight T5 retrofit kit.
DO NOT replace retrofit kit with the originally intended lamp(S) unless a re-installation has
been carried out by a licensed electrician.
IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK.
# Wiring 7: 1 Disconnect the YELLOW wires from
the ballast and connect to the LINE by using the wire connector. See below.
2 Make sure the polarity of LINE match with the T5 end-cap.
3 The LIVE (L) of retrofit is always wired to right metal pin.
4 The RED and Blue wires connecting to the dummy lampholder can be removed or disconnected.
5 Any leads must be capped.
Connection Diagram before installation
LINE (LIVE & NEUTRAL) Connection Diagram before installation
WHITE BLACK
Fluorescent Lamp
Electronic Ballast
BLUE BLUE
Fluorescent Lamp
RED RED
LINE (LIVE & NEUTRAL)
WHITE BLACKThe Electronic
Ballast is bypassed!
T5 End Cap (G13)
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
13
1) The EcoLight® T5 Retrofit Kit is provided with an external wire to ground the retrofit unit. Both wire ends have a ring terminal for easy installation to the existing luminaries. The products also come with a star washer for scratching the painted surface and a screw for fixing the wire.
2) In general, the existing luminaries will incorporate a suitable attachment point for grounding. If it does,
connect the wire to that position with the star washer at the bottom, ring terminal at the middle and the screw is on top. If not, the installer has to drill a hole of 0.125 (1/8)” diameter (Φ3 to Φ4 (mm)) in proper position near the retrofit luminaire. The wire can also be connected directly to the grounding wire or position of the existing luminaries.
3) By using a proper tool, fix the ring terminal to the grounding position or drilled hole. To ensure proper
grounding, the star washer must scratch the painted surface of the existing luminaire completely. Remark: The products (FSA, FSI FAU and FAH series) are intended to be installed in a Listed T8-T12 open or enclosed fluorescent surface or recessed (Type Non-IC) luminaire with a maximum 4 lamp configuration in 2-foot, 3-foot 5-foot and 4-foot length.
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
14
Circuit Diagram:
Models with UL and ULc listed:
Models: T5/28BSA, T5/28FSA, T5/28BAH, T5/28FAH.
Models: T5 14FAU, T5 21FAU, T5 28FAU, T5 35FAU, T5 54FAU, T5 14BAU, T5 21BAU, T5 28BAU, T5 35BAU, T5 54BAU.
Models: T5 24FAH, T5 35FAH, T5 49FAH, T5 54FAH, T5 24BAH, T5 35BAH, T5 49BAH, T5 54BAH.
Models: T5 14FSI, T5 21FSI, T5 28FSI, T5 35FSI, T5 14BSI, T5 21BSI, T5 28BSI, T5 35BSI.
Standard T5 Tube
Neutral
Live
T5 Electronic Ballast in
aluminium housing
www.ecopower.com Regular Series V2.1UL 27 Oct 2010
15
Important Notices: 1) WARNING – Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, ballast,
or any other electrical component. 2) Only those open holes indicated in the photographs and/or drawings may be made or altered as a
result of kit installation. Do not leave any other open holes in an enclosure of wiring of electrical components.
3) Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
4) WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. The models (FSA, FSI, FAU and FAH) are “Not for use with dimmers” or Not for use in Luminaries controlled by a dimmer”.
5) CAUTION – Risk of Electric Shock – Use in Dry Locations Only. 6) The models (FSA, FSI, FAU and FAH) are not intended for use with emergency exit luminaires or
emergency exit lights. 7) To ensure safety, main power should be disconnected during installation. 8) Only qualified persons shall install the unit. 9) Although the ballast and wires inside the luminaire are built with double-insulation, grounding may be
necessary in some locations. Check local regulatory requirements. 10) Ensures that the installation complies with the information contained in this publication. 11) WARNING –The luminaire has been modified to accommodate EcoLight T5 retrofit kit. DO NOT
replace retrofit kit with the originally intended lamp(S) unless a re-installation has been carried out by a licensed electrician. IMPROPER RE-INSTALLATIN MAY CAUSE RISK OF FIRE OR RISK OF SHOCK
12) Make sure the lines (Live and Neutral) are connected to one end of lamp holder and keep the other unconnected.
13) All tubular fluorescent luminaire retrofit kits that require both line and neutral power to be connected to the same lampholder.
14) WARNING–Risk of fire or shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, please contact us.
EcoPower Electric Limited, or their agents do not assume any liability, expressed or implied, for any consequences resulting from inappropriate, negligent or incorrect installation, application, use or adjustment of the product or circuit design, or from the mismatch of the unit to a lamp.