T4 Physical Treatment Air Stripping
Transcript of T4 Physical Treatment Air Stripping
![Page 1: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/1.jpg)
Physical Treatment
Air Stripping
(Section 9 – 1)
![Page 2: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/2.jpg)
Volatility
• Tendency to move from solution to gas phase
• Function of:– Vapor pressure (VP)– Molecular weight (MW)– Henry’s constant (H)– Solubility (S)– etc.
![Page 3: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/3.jpg)
Henry’s Law Constant (H)
TR
HH
JTR
HH
eoreH
S
VP
C
C
C
PH
C
C
BT
A
T
BA
L
G
L
G
'
log
![Page 4: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/4.jpg)
AWWA Equation Factors
Compound H x 10-3 JOxygen 1.45 7.11
Methane 1.54 7.22
Hydrogen sulfide 1.85 5.88
Carbon dioxide 2.07 6.73
Carbon tetrachloride 4.05 10.06
Trichloroethylene 3.41 8.59
Bezene 3.68 8.68
Chloroform 4.00 9.10
![Page 5: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/5.jpg)
Henry’s Law Constants
![Page 6: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/6.jpg)
Equipment
• Spray systems
• Aeration in contact tanks
• Tray towers
• Packed towers
![Page 7: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/7.jpg)
Aeration in Tanks
![Page 8: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/8.jpg)
Tray Towers
![Page 9: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/9.jpg)
Packed Towers
![Page 10: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/10.jpg)
Liquid Distribution Systems
![Page 11: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/11.jpg)
Design of Air Stripping Column
Parameters
– Chemical properties– Range of influent flow rates, temperatures,
and concentrations– Range of air flow rates and temperatures– Operation as continuous or batch– Packing material
![Page 12: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/12.jpg)
Packing
![Page 13: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/13.jpg)
Fouling
![Page 14: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/14.jpg)
Cleaning Packing
![Page 15: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/15.jpg)
Comparison: Equipment
![Page 16: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/16.jpg)
Design, in General
• Tower diameter function of design flow rate
• Tower height function of required contaminant removal
![Page 17: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/17.jpg)
Diameter of Column
504
.
L
QD
![Page 18: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/18.jpg)
Depth of Packing Design Equations
Assumptions:
– Plug flow– Henry’s Law applies– Influent air contaminant
free– Liquid and air volumes
constant
![Page 19: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/19.jpg)
Depth of Packing
– L = liquid loading rate (m3/m2/s)– KLa = overall mass transfer rate constant (s-1)– R = stripping factor– C = concentration
))((
11
ln1
NTUHTUR
RCC
R
R
aK
LZ out
in
L
![Page 20: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/20.jpg)
Stripping Factor (R)
• Process: mass balance on contaminant
• Initial assumptions:– Previous– Plus
• dilute solution• no accumulation• no reactions• 100% efficient
![Page 21: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/21.jpg)
Example: Removal Efficiency
Calculate the removal efficiency for an air stripper with the following characteristics.
– Z = 12.2 m
– QW = 0.28 m3/s
– H’ = 0.2315
– QA = 5.66 m3/s
– KLa = 0.0125 s-1
– D = 4.3 m
![Page 22: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/22.jpg)
Activity – Team
Ethylbenzene needs to be removed from a wastewater. The maximum level in the wastewater is 1 mg/L. The effluent limit is 35 g/L. Determine the height of an air stripping column. The following data is available:
– KLa = 0.016 s-1
– QW = 7.13 L/s– T = 25 oC– D = 0.61 m– QA/QW = 20– T = 25 oC
![Page 23: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/23.jpg)
More on Stripping Factor
imum
operating
LG
LGR
ratiowatertoairimumltheoretica
ratiowatertoairoperatingactualR
min/
/
min
'
1)/( min HC
CCLG
in
outinimum
imumoperating LGRLG min)/()/(
![Page 24: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/24.jpg)
KLa: Two-Film Theory
Bulk Liquid Bulk AirLiquid Film Air Film
CL
PG
CI
PI
![Page 25: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/25.jpg)
KLa: Transfer Rate
• KLa (s-1)
– KL = liquid mass transfer coefficient (m/s)
– a = area-to-volume ratio of the packing (m2/m3)
• Determination:– experimentally– Sherwood-Holloway equation– Onda correlations
![Page 26: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/26.jpg)
KLa: Column Test
• System– Small diameter column– Packing material– Blower– Pump– Contaminated water
• Test– Range of liquid loading rates– Range of air-to-water ratios
![Page 27: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/27.jpg)
Column Test Continued
• Determining KLa
– Plot sample (packing) depth vs. NTU (which varies based on Ce/Ci)
– Slope = 1/HTU
– KLa = L/HTU
![Page 28: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/28.jpg)
Example: Column Test
Sampling Port Depth (m) TCE (µg/L)
0 230
2 143
4 82
6 48
8 28
![Page 29: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/29.jpg)
Example continued
0
0.5
1
1.5
2
2.5
0 2 4 6 8 10
Z (m)
NT
U
![Page 30: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/30.jpg)
Sherwood-Holloway Equation
– L = liquid mass loading rate (kg/m2/s) = liquid viscosity (1.002 x 10-3 Pa-s at 20 oC = water density (998.2 kg/m3 at 20 oC) , n = constants (next slide)
– DL = liquid diffusion coefficient (m2/s)• Wilke-Chang method• B T/
5.01
305.0
L
n
LL D
LDaK
![Page 31: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/31.jpg)
Sherwood-Holloway Constants
Packing Size (mm) n
Raschig rings 12 920 0.35
25 330 0.22
38 295 0.22
50 260 0.22
Berl saddles 12 490 0.28
25 560 0.28
38 525 0.28
Tile 75 360 0.28
![Page 32: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/32.jpg)
DL: Wilke-Change Method
• DL = liquid diffusion coefficient (cm2/s)• T = temperature (K) = water viscosity (0.89 cP at 25 oC)• V = contaminant molal volume (cm3/mol)
6.0
71006.5
V
TxDL
![Page 33: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/33.jpg)
DL: Conversion Constant B
Compound B x 1015
Carbon tetrachloride 2.76Trichloroethylene 2.86Benzene 3.04Chloroform 3.12Vinyl chloride 3.85Chloromethane 4.49Methane 6.18
![Page 34: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/34.jpg)
Onda Correlations
• Accounts for gas-phase and liquid-phase resistance
• Better for slightly soluble gases
• No empirical constants
![Page 35: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/35.jpg)
Gas Pressure Drop
• Physical parameter: describes resistance blower must overcome in the tower
• Function of:– gas flow rate– water flow rate– size and type of packing– air-to-water ratio
• Found from gas pressure drop curve
![Page 36: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/36.jpg)
Example: Pressure Drop Figure
Determine the air and liquid loading rates for a column test to remove TCE. The stripping factor is 5 when 51-mm Intalox saddles are used at a pressure drop of 100 N/m2/m. The influent concentration is 230 g/L and the effluent concentration is 5 g/L. The temperature is 20oC.
![Page 37: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/37.jpg)
Preliminary Design
• Determine height of packing – Z = (HTU) (NTU)
– Zdesign = Z (SF)
• Determine pressure drop and impact on effluent quality by varying air-to-water ratio (QA/QW) and the packing height (Z)
![Page 38: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/38.jpg)
Activity – Team
Determine the dimensions of a full-scale air stripping tower to remove toluene from a waste stream if the flow rate is 3000 m3/d, the initial toluene concentration is 230 g/L, and the design effluent concentration is 1 g/L. Assume that the temperature of the system is 20 0C. A pilot study using a 30-cm diameter column, 25-mm Raschig rings, a stripping factor of 4, and a pressure drop of 200 N/m2/m generated the following data.
Depth (m) [Toluene] (g/L)0 2302 524 216 68 1.5
![Page 39: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/39.jpg)
Design Procedure
• Select packing material. Higher KLa and lower pressure drop produce most efficient design.
• Select air-to-water ratio and calculate stripping factor or select stripping factor and calculate operating air-to-water ratio.
• Calculate air flow rate based on selected gas pressure drop and pressure drop curve.
![Page 40: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/40.jpg)
Design Procedure Continued
• Determine liquid loading rate from air-to-water ratio.
• Conduct pilot studies using gas and liquid loading rates. Develop NTU data from Ce/Ci, and calculate KLa.
• Determine tower height and diameter.
• Repeat using matrix of stripping factors.
![Page 41: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/41.jpg)
Comparison: QA/Qw & Z
![Page 42: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/42.jpg)
Discharged Air
• Recover and reuse chemical
• Direct discharge
• Treatment
![Page 43: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/43.jpg)
Common Design Deficiencies
• Poor efficiency due to low volatility• Poor effluent quality due to insufficient packing
height/no. of trays• Poor design due to inadequate equilibrium data
and/or characterization data• Inadequate controls for monitoring• Heavy entrainment due to no mist eliminator• Not sheltered so difficult to maintain in inclement
weather• Lines freeze during winter shutdowns due to no
drains or insulation
![Page 44: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/44.jpg)
More Design Deficiencies
• Tray Towers– Inadequate tray seals– Heavy foaming– Trays corroded
• Packed Towers– Inadequate packing wetness due to poor loading
and/or inadequate redistribution– No means to recycle effluent to adjust influent flow– Plugging due to heavy solids or tar in feed– Inadequate blower capacity
![Page 45: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/45.jpg)
Physical Treatment
Steam Stripping
(Section 9 – 3)
![Page 46: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/46.jpg)
Steam Stripping
![Page 47: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/47.jpg)
Steam Stripping Design
• Strippability of organics
• Separation of organic phase from steam in decanter
• Fouling
![Page 48: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/48.jpg)
Rules of Thumb
• Strippability– Any priority pollutant analyzed by direct
injection on a gas chromatograph– Any compound with boiling point < 150 oC
and H > 0.0001 atm-m3/mol
• Separate phase formation– At least one compound with low solubility
• Operating parameters– SS < 2%– Operating pressures as low as possible
![Page 49: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/49.jpg)
Example – Feasibility Analysis
Mixture A
– 37 mg/L methanol– 194 mg/L ethanol– 114 mg/L n-butanol
Mixture B
– 37 mg/L methanol– 194 mg/L ethanol– 114 mg/L n-butanol– 110 mg/L toluene– 14 mg/L xylene
![Page 50: T4 Physical Treatment Air Stripping](https://reader035.fdocuments.net/reader035/viewer/2022081507/5516fdc249795933228b4686/html5/thumbnails/50.jpg)
Common Design Deficiencies
• High packing breakage due to thermal stresses
• Heavy fouling due to influent characteristics & elevated temperature
• Inadequate steam capacity• No control for steam flow• Dilute overhead product due to
inadequate enriching section• Inadequate decanter to separate
immiscible phase