System Appliances Division Training Manual VIVALDI -P/J AQ09/12UBBXAZ AS09/12UBBXAZ.
-
Upload
ophelia-howard -
Category
Documents
-
view
215 -
download
0
Transcript of System Appliances Division Training Manual VIVALDI -P/J AQ09/12UBBXAZ AS09/12UBBXAZ.
2
CONTENTS
1. FEATURE
2. Structure
3. Connecting Diagram
4. Diagram Schematic
5. Error Mode
6. Troubleshooting
7. Working Principle
9. Refrigerating Cycle Diagram
8. Disassembly and Assembly
5
Feature – 2. Product Striking Concept
Do you worry about your electricity bills when using the air conditioner?
Do you switch off your air conditioner when you feel the room is cool/warm enough
and turn on the set again when the air is not comfortable anymore, to save electricity?
Now, you can have an air conditioner which operates for minimum time
keeping your room air comfortable and saves electricity consumption!
(Standard & Deluxe)
Smart Saverstops operating the air conditioner when the room air reaches the set temperatureto save electricity consumption and turns it on again after a certain time.This function saves 30-40% of electricity than usual operations.
(Current saving functions are lack of visibility and practicality and thus consumers can hardly trust them.)
Smart Saver
6
Feature – 2. Product Striking Concept
Filter Cleaning Indi-cator
Do you know your air conditioner has filters that purify the air of your room?
Do you feel uncomfortable because you do not know when you should clean the filters?
Now, you can have an air conditioner with silver-coated filters
which eliminate dust particles in the air, and with an indicating light
which automatically turns on when you need to clean the filters!
(Deluxe, Optional)
Filter Cleaning Indicator
calculates the operating time of an air conditionerand turns on the lightwhen the filters should be cleaned
Silver-coated filters remove dust particlesin the air and protect itself from virusesto provide the purified clean air
Purified Clean Air
Silver-coated Filters
37
Working Principle – 2. CROSS FAN DISASSEMBLING METHOD
The Indoor Cross Fan can be drown out by loosening 1 screwWithout disassembling other items (ex. Assy control in, Motor, Holder Motor etc.).