SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault...

60
INSTALLATION MANUAL 1st Edition (Revised 2) SWITCHER PROCESSOR PACK MFS-2000-C MFS-2000 MULTI FORMAT SWITCHER PROCESSOR HK-PSU02 HK-PSU11 MKS-2010 MKS-2015 MKS-2017 MKS-2110M MKS-2420M MKS-2440 MKS-2470 BZS-2000M BZS-2440M BZS-2470M

Transcript of SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault...

Page 1: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

INSTALLATION MANUAL1st Edition (Revised 2)

SWITCHER PROCESSOR PACK

MFS-2000-CMFS-2000MULTI FORMAT SWITCHER PROCESSOR

HK-PSU02 HK-PSU11

MKS-2010 MKS-2015 MKS-2017

MKS-2110M MKS-2420M MKS-2440

MKS-2470

BZS-2000M BZS-2440M BZS-2470M

Page 2: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

MFS-2000 IM

MFS-2000 Serial No. 10001 and HigherMKS-2010 Serial No. 10001 and HigherMKS-2015 Serial No. 10001 and HigherMKS-2017 Serial No. 10001 and HigherMKS-2110M Serial No. 10001 and HigherMKS-2420M Serial No. 10001 and HigherMKS-2440 Serial No. 10001 and HigherMKS-2470 Serial No. 10001 and HigherHK-PSU02 Serial No. 10001 and HigherHK-PSU11 Serial No. 10001 and HigherBZS-2000MBZS-2440MBZS-2470M

! WARNINGThis manual is intended for qualified service personnel only.To reduce the risk of electric shock, fire or injury, do not perform any servicing other than thatcontained in the operating instructions unless you are qualified to do so. Refer all servicing toqualified service personnel.

! WARNUNGDie Anleitung ist nur für qualifiziertes Fachpersonal bestimmt.Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um dieGefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind beiWartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegebenWartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigungdazu besitzen.

! AVERTISSEMENTCe manual est destiné uniquement aux personnes compétentes en charge de l'entretien. Afin deréduire les risques de décharge électrique, d'incendie ou de blessure n'effectuer que lesréparations indiquées dans le mode d'emploi à moins d'être qualifié pour en effectuer d'autres.Pour toute réparation faire appel à une personne compétente uniquement.

Page 3: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

MFS-2000 IM 1 (P)

WARNINGThis unit has no power switch.When installing the unit, incorporate a readilyaccessible disconnect device in the fixed wiring, orconnect the power cord to a socket-outlet which must beprovided near the unit and easily accessible, so that theuser can turn off the power in case a fault should occur.

WARNUNGDieses Gerät hat keinen Netzschalter.Beim Einbau des Geräts ist daher im Festkabel einleicht zugänglicher Unterbrecher einzufügen, oder dasNetzkabel muß mit einer in der Nähe des Gerätsbefindlichen, leicht zugänglichen Wandsteckdoseverbunden werden, damit sich bei einerFunktionsstörung die Stromversorgung zum Gerätjederzeit unterbrechen läßt.

Attention-when the product is installed in Rack:

1. Prevention against overloading of branch circuitWhen this product is installed in a rack and issupplied power from an outlet on the rack, pleasemake sure that the rack does not overload the supplycircuit.

2. Providing protective earthWhen this product is installed in a rack and issupplied power from an outlet on the rack, pleaseconfirm that the outlet is provided with a suitableprotective earth connection.

3. Internal air ambient temperature of the rackWhen this product is installed in a rack, please makesure that the internal air ambient temperature of therack is within the specified limit of this product.

4. Prevention against achieving hazardouscondition due to uneven mechanical loadingWhen this product is installed in a rack, please makesure that the rack does not achieve hazardouscondition due to uneven mechanical loading.

5. Install the equipment while taking the operatingtemperature of the equipment into considerationFor the operating temperature of the equipment, referto the specifications of the Operation Manual.

6. When performing the installation, keep thefollowing space away from walls in order toobtain proper exhaust and radiation of heat.. MFS-2000

Front, Right, Left : 10 cm (4 inches) or more. MKS-2010/2015

Front, Back, Right, Left : 10 cm (4 inches) or more. MKS-2017

Front, Back, Right : 10 cm (4 inches) or more

For safety, do not connect the connector for peripheraldevice wiring that might have excessive voltage to thefollowing port(s).MFS-2000: SWITCHER DATA connector: DME DATA (Digital Multi Effect Data) connector: SWITCHER CTRL (switcher control) connector: DME CTRL (Digital Multi Effect control) connectorMKS-2010/2015/2017: PERIPH (peripheral) connector: CTRL (control) connector: DATA connectorMKS-2440: FM DATA connectorFollow the instructions for the above port(s).

For MKS-2010/2015/2017

For the customers in the NetherlandsVoor de klanten in Nederland

Hoe u de batterijen moet verwijderen, leest u in deOnderhoudshandleiding.

Gooi de batterij niet weg maar lever deze in als kleinchemisch afval (KCA).

Für Kunden in Deutschland

Entsorgungshinweis: Bitte werfen Sie nur entladeneBatterien in die Sammelboxen beim Handel oder denKommunen. Entladen sind Batterien in der Regel dann,wenn das Gerät abschaltet und signalisiert “Batterieleer” oder nach längerer Gebrauchsdauer der Batterien“nicht mehr einwandfrei funktioniert”. Umsicherzugehen, kleben Sie die Batteriepole z.B. miteinem Klebestreifen ab oder geben Sie die Batterieneinzeln in einen Plastikbeutel.

Page 4: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...
Page 5: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

1MFS-2000 IM

Table of Contents

Manual Structure

Purpose of this manual .............................................................................................. 3

Related manuals ......................................................................................................... 3

Trademarks ................................................................................................................ 3

Contents ..................................................................................................................... 4

1. Preparation for Installation

1-1. Operating Environment ............................................................................... 1-1

1-2. Power Supply .............................................................................................. 1-11-2-1. Power Specifications .................................................................. 1-11-2-2. Recommended Power Cord ........................................................ 1-2

2. Installation of the Processor

2-1. External Dimensions ................................................................................... 2-1

2-2. Removing/Reinstalling Front Panel ............................................................ 2-2

2-3. Installing the Options .................................................................................. 2-22-3-1. Installing Plug-in Boards ............................................................ 2-32-3-2. Installing Connector Board ........................................................ 2-42-3-3. Installing HK-PSU02 ................................................................. 2-42-3-4. Installing BZS-2000M/2440M/2470M ...................................... 2-42-3-5. Installing MKS-2420M .............................................................. 2-5

2-4. Rack Mounting the Processor ..................................................................... 2-6

2-5. Description of On-board Switches and LEDs ............................................. 2-8

3. Installation of the Control Panel

3-1. Installation Space ........................................................................................ 3-13-1-1. External Dimensions .................................................................. 3-13-1-2. Installation Space ....................................................................... 3-4

3-2. Removing/Reinstalling Front Panel ............................................................ 3-7

3-3. Installing the Options .................................................................................. 3-83-3-1. Installing HK-PSU11 ................................................................. 3-8

3-4. Description of On-board Switches and LEDs ........................................... 3-10

3-5. Installing on the Control Console ............................................................. 3-113-5-1. MKS-2010 ................................................................................ 3-113-5-2. MKS-2015/2017 ....................................................................... 3-13

Page 6: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2 MFS-2000 IM

4. Connection

4-1. Matching Connectors and Cables ................................................................ 4-1

4-2. Input/Output Signals of Connectors ............................................................ 4-2

4-3. System Connection ...................................................................................... 4-5

4-4. Setup ............................................................................................................ 4-6

5. Service Overview

5-1. Troubleshooting .......................................................................................... 5-15-1-1. Processor .................................................................................... 5-15-1-2. Control Panel .............................................................................. 5-2

5-2. Periodic Inspection and Maintenance ......................................................... 5-35-2-1. Cleaning ..................................................................................... 5-3

5-3. Data Backup Capacitor ............................................................................... 5-4

Page 7: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3MFS-2000 IM

Purpose of this manualThis manual is the installation manual of Switcher Processor Pack MFS-2000-C andits optional boards and units.This manual is intended for use by trained system and service engineers, anddescribes the information on installing the MFS-2000-C system.

The MFS-2000 is described as the processor, and the MKS-2010/2015/2017 aredescribed as the control panel in this manual.

Related manualsThe following manuals are prepared for MFS-2000-C and its optional boards andunits.

..... Operation Manual (Supplied with MFS-2000-C)This manual describes the application and operation of MFS-2000-C system.

..... User’s Guide (Supplied with MFS-2000-C)This manual is required for detailed application and operation of the MFS-2000-Csystem.

..... Maintenance Manual (Available on request)This manual describes the detailed service information.If this manual is required, please contact your local Sony Sales Office/ServiceCenter.

..... “Semiconductor Pin Assignments” CD-ROM (Available on request)This “Semiconductor Pin Assignments” CD-ROM allows you to search forsemiconductors used in B&P Company equipment.Semiconductors that cannot be searched for on this CD-ROM are listed in themaintenance manual for the corresponding unit. The maintenance manual containsa complete list of all semiconductors and their ID Nos., and thus should be usedtogether with the CD-ROM.Part number: 9-968-546-XX

TrademarksTrademarks and registered trademarks used in this manual are follows.

. Memory Stick is a trademark of Sony Corporation.

. Ethernet is a registered trademark of Xerox Corporation.

Other system names and the product names described in this manual are trademarksor registered trademarks of their respective holders.

Manual Structure

Page 8: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4 MFS-2000 IM

ContentsThis manual is organized by following sections.

Section 1 Preparation for InstallationDescribes the circumstance of use and power of the processor and control panel.

Section 2 Installation of the ProcessorDescribes the processor’s installation information (removal/installation of the frontpanel, the installation of the options, the rack mounting, the settings of the on-boardswitch and the function of LED).

Section 3 Installation of the Control PanelDescribes the control panel’s installation information (installation space, the remov-al/installation of the front panel, the installation of the options, and the settings ofthe on-board switch and the function of LED).

Section 4 ConnectionDescribes the processor’s and control panel’s connection information (matchingconnectors/cables, the I/O signals of the connector, the example of the systemconnection).

Section 5 Service OverviewDescribes the troubleshooting of the processor and the control panel, the periodicinspection, and the capacitor for backing up the data.

Page 9: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

1-1MFS-2000 IM

Section 1Preparation for Installation

1-1. Operating Environment

Operating guaranteed temperature : +5 dC to +40 dCPerformance guaranteed temperature : +10 dC to +35 dCOperating humidity : 10 % to 90 %

(relative humidity)Storage temperature : _20 dC to +60 dCMass (when all options are installed) :

MFS-2000 : Approx. 22 kgMKS-2010 : Approx. 10.3 kgMKS-2015 : Approx. 11.3 kgMKS-2017 : Approx. 12.6 kg

Prohibited locations for installation. Areas where the unit will be exposed do direct sunlight

or any other strong lights. Dusty areas. Areas subject to vibration. Areas with strong electric or magnetic fields. Areas near heat sources. Areas subject to electrical noise. Areas subject where is subjected to static electricity

Ventilation of the processorThe inside of the processor is cooled by a fan (on bothsides).The power supply can be damaged if the exhaust vent (onboth sides) and air intake (on the front panel) are blockedor the fan is stopped.Therefore, leave room of more than 10 cm in the front andboth sides of the processor.

Ventilation of the control panelThe inside of the control panel is cooled by a fan (on theside).The power supply can be damaged if the exhaust vent andair intake (on both sides and the rear) are blocked or thefan is stopped.Therefore, leave room of more than each 10 cm in thefront, back, right and left sides. (There is no need ofleaving room on the left side of the MKS-2017.)When you install the control panel to the rack, be sure notto block the exhaust vent/air intake on the sides of thecontrol panel.

1-2. Power Supply

wThere is no power switch on the control panel.Set the dedicated breaker.

1-2-1. Power Specifications

The switching regulator is used for the power of theprocessor and the control panel. The voltage within therange of 100 V to 240 V can be used without changing thesupply voltage.

Power requirements : AC 100 - 240 VPower frequency : 50/60 HzCurrent consumption (when all options are installed) :

MFS-2000 : 4.5 - 2.1 AMKS-2010 : 1.0 - 0.5 AMKS-2015 : 1.0 - 0.5 AMKS-2017 : 1.0 - 0.6 A

m(Processor). As the inrush current at turn-on is a maximum 12 A (at

100 V)/33 A (at 230 V), the capacity of the AC powersource must be commensurate with this load.If the capacity of the AC power is not adequately large,the AC power source breaker will operate or the unit willabnormally operate.

. The processor contains the two power supply units as thestandard configuration. A maximum of three powersupply units may be installed. When starting up theprocessor, be sure to turn on the power of two or morepower supply units.

n(Control panel). As the inrush current at turn-on is a maximum 12 A (at

100 V)/28 A (at 230 V), the capacity of the AC powersource must be commensurate with this load.If the capacity of the AC power is not adequately large,the AC power source breaker will operate or the unit willabnormally operate.

Page 10: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

1-2 MFS-2000 IM

1-2-2. Recommended Power Cord

Neither the processor nor control panel come with a powercord.To get a power cord, please contact your local Sony SalesOffice/Service Center.

w. Use the approved Power Cord (3-core mains lead)/

Appliance Connector/Plug with earthing-contacts thatconforms to the safety regulations of each country ifapplicable.

. Use the Power Cord (3-core mains lead)/ApplianceConnector/Plug conforming to the proper ratings (Volt-age, Ampere).

If you have questions on the use of the above Power Cord/Appliance Connector/Plug, please contact your local SonySales Office/Service Center.

w. Never use an injured power cord.. Plugging the power cord in the AC inlet, push as far as it

will go.

For customers in the U.S.A. and Canada1 Power cord, 125 V 10 A (2.4 m) : ! 1-557-377-11

AC inlet1

For customers in the all European countries1 Power cord, 250 V 10 A (2.4 m) : ! 1-782-929-21

1 AC inlet

Page 11: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-1MFS-2000 IM

Section 2Installation of the Processor

B3

B3

B3

520 38

061

φ26

4

132.

417

.5

440

375482 Unit : mm

2-1. External Dimensions

Page 12: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-2 MFS-2000 IM

2-3. Installing the Options

The MFS-2000-C is shipped from the factory with thenecessary option boards (refer to the following table)already installed in accordance with the specified systemconfiguration.The following options are available for the processor.

Option list for the processor

Model name Board configuration

Plug-in board Connector board

MKS-2110M _ CN-2486 boardINPUT/OUTPUTCONNECTOR BOARD

MKS-2420M (CC-95 board*2) _COLOR CORRECTORBOARD

MKS-2440 MY-112 board CN-2535 boardFRAME MEMORYBOARD SET

MKS-2470 DVP-30 board _DME BOARD SET CA-54CFB board

HK-PSU02 _ _POWER SUPPLY UNIT

BZS-2000M*1 _ _SWITCHER UPGRADESOFTWARE

BZS-2440M*1 _ _FRAME MEMORYUPGRADE SOFTWARE

BZS-2470M*1 _ _DME UPGRADE SOFTWARE

*1 : BZS-2000M, BZS-2440M and BZS-2470M are the software options.*2 : The CC-95 board is the option board to install on the MY-112 board.

2-2. Removing/Reinstalling Front Panel

Removal1. Turn off the main powers of the processor and discon-

nect the AC power cords from the wall outlet.2. Tighten the four screws (with drop-safe) and remove

the front panel.

Screws (with drop-safe)

Screws (with drop-safe)

Front panel

ReinstallationInsert the front panel securely into the chassis and tightenthe four screws (with drop-safe).nTo install the front panel, fit the protrusions of the chassisinto the grooves in the front panel.

Front panel

Protrusions

Protrusions

Grooves

Grooves

Page 13: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-3MFS-2000 IM

2-3-1. Installing Plug-in Boards

Each plug-in board is allocated to a specific slot into whichthey must be installed. Check that the respective plug-inboards are installed in their respective slots.The name of the board is shown near the eject lever at theleft-most end of each plug-in board.Names of the plug-in boards and the slot numbers, towhich the plug-in boards are allocated, are shown on theboard retainer inside the front panel of the processor.Install the respective plug-in boards according to thisinstruction.

m. If any plug-in board is inserted into the incorrect slot, it

causes a system error and the system will not workcorrectly.

. Check that the connectors of the plug-in boards aresecurely inserted into the mother board (MB-1021board) without loose contact.

cBe sure to turn off the POWER switches before startinginstallation work.If installation work is started with the POWER switch lefton, it may cause electrical shock or damage to printedcircuit boards.

Installation1. Turn off the main powers of the processor and discon-

nect the AC power cords from the wall outlet.2. Remove the front panel. (Refer to Section 2-2.)3. Remove the four screws and remove the board retainer.

4. While holding the eject levers open, insert the plug-inboard into the board guide rails.

Board retainer

B3 x 5

B3 x 5

Option model name Board name Installation slot(front side)

MKS-2440 MY-112 board 6

MKS-2470 DVP-30 board 1

CA-54CF board 2

5. Push in the plug-in board and close the eject levers inthe direction of arrow 1.

6. Attach the board retainer and the front panel by revers-ing the installation steps of 2 and 3.nAfter installing the plug-in board, the software must beinstalled. Install the software of V2.20 or later version.For installing the software, refer to the user’s guide ofthe MFS-2000 system.

Eject levers

Plug-in board

1 1

Page 14: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-4 MFS-2000 IM

2-3-2. Installing Connector Board

1. Remove the two screws and remove the blank panel.m. To install the connector board into the slot in which

the other board is installed already, loosen the twofixing screws and remove the connector boardinstalled already.

. Store the removed blank panel in a safe place.

2. Insert the connector board horizontally level andsecure it with the two fixing screws.

Option model name Board name Installation slot(rear side)

MKS-2110M CN-2486 board 5

MKS-2440 CN-2535 board 6

Blank panel

B3 x 5

B3 x 5

Fixing screw

Connector board

Fixing screw

2-3-3. Installing HK-PSU02

The HK-PSU02 is used in the processor.

cBefore installing an HK-PSU02 in processor, set thePOWER switch of the HK-PSU02 to the “O” position(OFF).

1. Turn off the main powers of the processor and discon-nect the AC power cords from the outlet.

2. Remove the front panel. (Refer to Section 2-2.)3. Remove the two screws that secure the blank panel

and remove the blank panel.

nStore the removed blank panel in a safe place.

4. Insert the HK-PSU02 securely into the deep end.5. Secure the HK-PSU02 with the two screws, which are

removed in the step 3.

6. Reinstall the front panel.

2-3-4. Installing BZS-2000M/2440M/2470M

For the installation procedure of the software options BZS-2000M/2440M/2470M, refer to the MFS-2000 SystemUser’s Guide.

Blank panel

PSW3 x 6

PSW3 x 6

Page 15: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-5MFS-2000 IM

2-3-5. Installing MKS-2420M

MKS-2420M is used while being mounted on MKS-2440(the MY-112 board).nStore the removed blank panel in a safe place.

1. Remove the four screws, and remove the blank panelmounted on the MY-112 board.

PSW3 x 5

PSW3 x 5

Blank panel

MY-112 board

2. Connect the CC-95 board to the connector (CN1) onthe MY-112 board.nInstall the CC-95 board carefully to prevent themounted parts on the backside of the CC-95 boardfrom being caught by the A portion.

3. Secure the CC-95 board with the four screws removedin step 1.

CN1

MY-112 board

CC-95 board

A portion

PSW3 x 5

PSW3 x 5

CC-95 board

Page 16: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-6 MFS-2000 IM

Rack mounting procedureThis section describes the rack mounting procedure usingthe RMM-10 rack mount kit.

nTighten the screws to the following torque.Tightening torque : 120 x 10_2 N.m (12.2 kgf.cm)

1. Remove four feet as required.

2. Attach the rack tools to the side of the equipment usingthe specified six screws.nUse B4 x 6 screws.

2-4. Rack Mounting the Processor

The processor installs in a 19-inch standard rack.To mount the processor in a rack, use the specified rackmount kit and follow the procedure described below.

Specified rack mount kit : RMM-10nIf a rack mount kit other than the specified one is used, theunit may not correctly install in a 19-inch standard rack.

Parts of the RMM-10. Rack tools 2 pcs. Right rack mount adaptor 1 pc. Left rack mount adaptor 1 pc. Rack tool attaching screws 6 pcs

(B4 x 6 : 7-682-560-09). Adaptor attaching screws 6 pcs

(B4 x 10 : 7-682-560-10)

Precautions for rack mountingw. To prevent the rack from falling or moving, fix the rack

on a flat and steady floor using bolts or other fixings.If the rack falls due to the weight of the equipment, itmay cause death or injury.

. Be sure to use the specified rack mount kit.If not, injury may result and the equipment may fall dueto insufficient strength.

. After rack mounting, be sure to tighten the screws on therack angle and fix the unit in the rack.

cWhen mounting the unit in the rack, note the following:. Be sure to mount in the rack with two persons or more.. Be careful not to catch your fingers or hands in the rack

mount rail or others.. Mount in the rack in a stable position.

nIf several units are mounted in a rack, it is recommendedthat a ventilation fan is installed to prevent temperature riseinside the rack.

FootFoot

B4 x 8B4 x 8

Rack tool

Rack tool

B4 x 6

B4 x 6

Page 17: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-7MFS-2000 IM

3. Loosen the screws on the rear of the right and leftadaptors and adjust the length of the adaptor accordingto the depth of the rack.(The illustration below shows the left adaptor.)

nMaximum depth of adaptor : 750 mmMinimum depth of adaptor : 595 mm

4. Attach the right and left adaptors to the rack complete-ly using the specified six screws.(The illustration below shows the left adaptor.)

Unit : mm

5. Tighten the screws (B4 x 6 : two screws each on theright and left) for adjusting the length of the adaptorcompletely (the screws that were loosened in step3).

6. Align the groove of the rack tool at the side of the equip-ment with the rail, and slide the equipment to the rear.nThe rack tools are hooked on the rails as shown below.

7. Remove the front panel. (Refer to Section 2-2.)8. Fix the rack angles in the rack using the specified

screws.

9. Attach the front panel to the equipment.

B4 x 10

3U

B4 x 10

31.75

31.75

Rack

Rack

Adaptor

Adaptor

B4 x 6

Portion of the rail

Adaptor

Rack tool Rack tool

Rail Rail

B5 x 12

B5 x 12

Rack

Rack angle

Rack angle

Page 18: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-8 MFS-2000 IM

A side/Component side

2-5. Description of On-board Switches and LEDs

nThe number shown in the parentheses ( ) indicates the address on the circuit board.

1. CA-54 board

1

2

3

4

5

A B C D E

ND101ND102ND901ND902

ND1101ND1102

D409D410D1002D1001D1201D1202

D101D102D103D104D901D902D903D904D1101D1102D1103D1104

D4D5D1303D601D602D704D701

S102

S103

S104S901

S1101

S402

S401

S403F

E

D

C

B

A

1 2 3 4 5

DI1

DI4

DI2

DI3

DI6

DI7

DI8

SW1

SW2

F

E

D

C

B

A

1 2 3 4 5

DI1

DI4

DI2

DI3

DI6

DI7

DI8

SW1

SW2

S902

S101

S1102

MAIN CPUModule*

CPU-DKModule

(COM CPU-1)

CPU-DKModule

(COM CPU-2)

D100D101D200

A

B

1 2

SG-272

S500S300

D202D201D200

A B C D E F G12

3

4

SIO-26

GFEDCBA

65

43

21

D12D18D19

D10D13

D14D15D16D17

SW2

SW1

CPU-DR Module

GFEDCBA

65

43

21

D11D13D14D18

D17D16D15D19

SW1

SW2

CPU-DT Module

***** : The CPU-DR module or CPU-DT module is used in the Main CPU module.

Page 19: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-9MFS-2000 IM

<LED>D4 (A-1) : +++++3.3 V+3.3 V power supply status indication.Lit when the +3.3 V power is supplied.

D5 (A-2) : +++++12 V+12 V power supply status indication.Lit when the +12 V power is supplied.If this LED does not light, the fuse may have blown.

D101, D102, D103, D104 (A-4), ND101 (A-3), ND102(A-4) : MAIN CPU status LEDMain CPU status indication.

D409 (A-2) : RESET status LEDSystem reset status indication.Lit when S401 is pressed or the power voltage drops to+3.3 V.

D410 (A-2) : CPU RESET status LEDCA-54 board reset status indication.Lit when S402 is pressed or the power voltage drops to+3.3 V.

D601 (A-2) : REF EXT status LEDREF IN signal presence/absence status indication.Lit when the REF signal is input to the REF IN connector.Not lit when the REF signal is not input to the REF INconnector.

D602 (A-2) : PLL LOCK status LEDREF IN signal format status indication.Lit when the REF IN signal matches with the switcherformat setup.

D701 (A-2) : SBUS RX status LEDS-BUS reception status indication.Lit while the data reception is in progress.

D704 (A-2) : SBUS TX status LEDS-BUS transmission status indication.Lit while the data transmission is in progress.

D901 (A-4), D902, D903, D904 (A-5) : COM CPU-1status LEDCOM CPU-1 status indication.

D1001 (A-2) : COM1 100 status LEDCOM CPU-1 Ethernet communication speed status indication.

Lit : 100 Mb/sNot lit : 10 Mb/s

D1002 (A-2) : COM1 ACT status LEDCOM CPU-1 Ethernet communication status indication.Lit while the data transmission or reception is in progress.

D1101, D1102, D1103, D1104 (A-5) : COM CPU-2status LEDCOM CPU-2 status indication.

D1201 (A-2) : COM2 ACT status LEDCOM CPU-2 Ethernet communication status indication.Lit while the data transmission or reception is in progress.

D1202 (A-2) : COM2 100 status LEDCOM CPU-2 Ethernet communication speed status indication.

Lit : 100 Mb/sNot lit : 10 Mb/s

D1303 (A-2) : +++++5 V+5 V power supply status indication.Lit when the +5 V power is supplied.

ND901, ND902 (A-4) : COM CPU-1 status LEDCOM CPU-1 status indication.

ND1101, ND1102 (A-4) : COM CPU-2 status LEDCOM CPU-2 status indication.

<Switch>S101 (A-3) : Mode setting switch for the main CPUSets the modes of the main CPU, but this switch is current-ly not in use. Factory setting is all OFF.

S102 (A-2) : Group ID setting switch for LANSets the group ID for connecting LAN.Factory setting and in standard use :Bit 1 : ONBits 2 to 8 : OFF

S103 (A-2) : Unit ID setting switch for LANSets the unit ID for connecting LAN. Do not change the setting.Factory setting :Bit 1 : ONBits 2 to 8 : OFF

Page 20: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-10 MFS-2000 IM

D13 (A-1) : +++++2.5 VIndicates the status of the +2.5 V power that is generatedby the VCC (CORE) and supplied to the CPU-DR module.Lit while the specified power is turned on.

D14, D15, D16, D17 (A-3) : STATUS1 to STATUS4status LEDUsed for maintenance purpose. Only the STATUS1 LED islit in normal operation.

D18 (A-4) : +++++3.3 VIndicates the status of the VCC (I/O) power that is suppliedto the CPU-DR module.Lit while the specified power is turned on.

D19 (A-4) : CORE status LEDIndicates the status of the VCC (CORE) power that issupplied to the CPU-DR module.Lit while the specified power is turned on.

<Switch on the CPU-DR module> : Main CPUSW1 (A-1) : RESET switchPressing this switch resets the CPU-DR module.nIn some machines in which the CPU-DR module isinstalled, the system reset may be activated.

SW2 (A-2) : MODE switchUsed only for production in the assembly factory. Allswitches are set to OFF for normal operation.Factory setting is all OFF.

<LED on the CPU-DT module> : Main CPUD19 (A-3) : RUN status LEDRUN status indication.Lit when the CPU-DT module starts operating.

D11 (A-6) : CD (Card Detect) status LEDLit when the CPU-DT module is inserted correctly to theparent board.

D13 (A-6) : +++++1.5 VIndicates the status of the +1.5 V power that is generatedby the VCC (CORE) and supplied to the CPU-DT module.Lit while the specified power is turned on.

D14 (A-6) : +++++3.3 VIndicates the status of the VCC (I/O) power that is suppliedto the CPU-DT module.Lit while the specified power is turned on.

S104 (A-4) : Monitor reset switch for the mainCPUUsed for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the mainCPU control terminal pin (CN103).

S401 (A-1) : System reset switchPressing this switch activates the system-reset and thesystem restarts.

S402 (A-1) : CA-CPU reset switchPressing this switch resets the CA-54 board.

S403 (B-1) : Switch setting the number of thepower supply unitsSets the number of the power supply units that are requiredfor this unit. Do not change the setting.Factory setting:Bits 1 and 2: ONBits 3 and 4: OFF

S901 (A-4) : Monitor reset switch for the COM CPU-1Used for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the COMCPU-1 control terminal pin (CN503).

S902 (A-4) : Modes setting switch for the COM CPU-1Sets the modes of the COM CPU-1, but this switch iscurrently not in use. Factory setting is all OFF.

S1101 (A-4) : Monitor reset switch for the COM CPU-2Used for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the COMCPU-2 control terminal pin (CN703).

S1102 (A-4) : Modes setting switch for the COMCPU-2Sets the modes of the COM CPU-2, but this switch iscurrently not in use. Factory setting is all OFF.

<LED on the CPU-DR module> : Main CPUD10 (A-1) : RUN status LEDRUN status indication.Lit when the CPU-DR module starts operating.

D12 (A-4) : CD (Card Detect) status LEDLit when the CPU-DR module is inserted correctly into theparent board.

Page 21: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-11MFS-2000 IM

<LED on the SG-272 board>D100 (B-1) : REF OK status LEDLit while V sync of the reference input is detected.

D101 (B-1) : REF EXT status LEDLit while sync signal is input to the reference input.

D200 (B-1) : LOCK status LEDLit while the machine is locked to the reference signal.

<LED on the SIO-26 board>D200 (A-3): Communication error indicationLit when a communication error occurs through the Editorport or the Serial Tally port.

D201 (A-3): Communication status indicationFlashes when a communication is performed through theEditor port.

D202 (A-3): Communication status indicationFlashes when a communication is performed through theSerial Tally port.

<Switch on the SIO-26 board>S300 (A-3): Switch for productionUsed only for production in the assembly factory.Do not change the setting.Factory setting is all OFF.

S500 (A-2): Reset switchInitializes the SIO-26 board.

D15, D16, D17, D18 (A-3, A-4, A-5) : STATUS1 toSTATUS4 LEDUsed for maintenance purpose.All LEDs are not lit in normal operation.

<Switch on the CPU-DT module> : Main CPUSW1 (A-2) : RESET switchPressing this switch resets the CPU-DT module.nIn some machines in which the CPU-DT module isinstalled, the system reset may be activated.

SW2 (A-1) : MODE switchPin-8 DIP switchUsed only for production in the assembly factory.All switches are set to OFF for normal operation.Factory setting is all OFF.

<LED on the CPU-DK module> : COM CPU-1: COM CPU-2

DI1 (B-5) : CD (Card Detect) status LEDLit when the CPU-DK module is inserted correctly to theparent board.

DI2 (F-3) : RUN status LEDLit when the CPU-DK module starts operating.

DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) : STATUS1to STATUS4 LEDUsed for maintenance purpose. Only the STATUS1 LED islit in normal operation.

DI4 (B-5) : +++++3.3 VIndicates the status of the VCC (CORE) and VCC (I/O)powers that are supplied to the CPU-DK module.Lit while the specified power is turned on.

<Switch on the CPU-DK module> : COM CPU-1: COM CPU-2

SW1 (D-5) : RESET switchPressing this switch resets the CPU-DK module.nIn some machines in which the CPU-DK module isinstalled, the system reset may be activated.

SW2 (C-5) : MODE switchUsed only for production in the assembly factory. Allswitches are set to OFF for normal operation.Factory setting is all OFF.

Page 22: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-12 MFS-2000 IM

A side/Component side

2. CA-54CFB board

1

2

3

4

5

A B C D E

ND101ND102ND901ND902

ND1101ND1102

D409D410D1002D1001D1201D1202

D101D102D103D104D901D902D903D904D1101D1102D1103D1104

D4D5D1303D601D602D704D701

S101

S102

S103

S104S901

S1101

S402

S401

S403TP1301F

E

D

C

B

A

1 2 3 4 5

DI1

DI4

DI2

DI3

DI6

DI7

DI8

SW1

SW2

F

E

D

C

B

A

1 2 3 4 5

DI1

DI4

DI2

DI3

DI6

DI7

DI8

SW1

SW2

A B C D E1

2

3

D3D6D7D1D4D2D5

S902S1102

DIF-130(PC CARD)

CPU-DKModule

(COM CPU-1)

CPU-DKModule

(COM CPU-2)

D100D101D200

A

B

1 2

SG-272

MAIN CPUModule*

GFEDCBA

65

43

21

D12D18D19

D10D13

D14D15D16D17

SW2

SW1

CPU-DR Module

GFEDCBA

65

43

21

D11D13D14D18

D17D16D15D19

SW1

SW2

CPU-DT Module

***** : The CPU-DR module or CPU-DT module is used in the Main CPU module.

Page 23: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-13MFS-2000 IM

<LED>D4 (A-1) : +++++3.3 V+3.3 V power supply status indication.Lit when the +3.3 V power is supplied.

D5 (A-2) : +++++12 V+12 V power supply status indication.Lit when the +12 V power is supplied.If this LED does not light, the fuse may have blown.

D101, D102, D103, D104 (A-4), ND101 (A-3), ND102(A-4) : MAIN CPU status LEDMain CPU status indication.

D409 (A-2) : RESET status LEDSystem reset status indication.Lit when S401 is pressed or the power voltage drops to+3.3 V.

D410 (A-2) : CPU RESET status LEDCA-54CFB board reset status indication.Lit when S402 is pressed or the power voltage drops to+3.3 V.

D601 (A-2) : REF EXT status LEDREF IN signal presence/absence status indication.Lit when the REF signal is input to the REF IN connector.Not lit when the REF signal is not input to the REF INconnector.

D602 (A-2) : PLL LOCK status LEDREF IN signal format status indication.Lit when the REF IN signal matches with the switcherformat setup.

D701 (A-2) : SBUS RX status LEDS-BUS reception status indication.Lit while the data reception is in progress.

D704 (A-2) : SBUS TX status LEDS-BUS transmission status indication.Lit while the data transmission is in progress.

D901 (A-4), D902, D903, D904 (A-5) : COM CPU-1status LEDCOM CPU-1 status indication.

D1001 (A-2) : COM1 100 status LEDCOM CPU-1 Ethernet communication speed statusindication.

Lit : 100 Mb/sNot lit : 10 Mb/s

D1002 (A-2) : COM1 ACT status LEDCOM CPU-1 Ethernet communication status indication.Lit while the data transmission or reception is in progress.

D1101, D1102, D1103, D1104 (A-5) : COM CPU-2status LEDCOM CPU-2 status indication.

D1201 (A-2) : COM2 ACT status LEDCOM CPU-2 Ethernet communication status indication.Lit while the data transmission or reception is in progress.

D1202 (A-2) : COM2 100 status LEDCOM CPU-2 Ethernet communication speed statusindication.

Lit : 100 Mb/sNot lit : 10 Mb/s

D1303 (A-2) : +++++5 V+5 V power supply status indication.Lit when the +5 V power is supplied.

ND901, ND902 (A-4) : COM CPU-1 status LEDCOM CPU-1 status indication.

ND1101, ND1102 (A-4) : COM CPU-2 status LEDCOM CPU-2 status indication.

<Switch>S101 (A-3) : Mode setting switch for the main CPUSets the modes of the main CPU, but this switch is current-ly not in use. Factory setting is all OFF.

S102 (A-2) : Group ID setting switch for LANSets the group ID for connecting LAN.Factory setting and in standard use :Bit 1 : ONBits 2 to 8 : OFF

Page 24: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-14 MFS-2000 IM

<LED on the CPU-DR module> : Main CPURefer to <LED on the CPU-DR module> in “1. CA-54board”.

<Switch on the CPU-DR module> : Main CPURefer to <Switch on the CPU-DR module> in “1. CA-54board”.

<LED on the CPU-DT module> : Main CPURefer to <LED on the CPU-DT module> in “1. CA-54board”.

<Switch on the CPU-DT module> : Main CPURefer to <Switch on the CPU-DT module> in “1. CA-54board”.

<LED on the CPU-DK module> : COM CPU-1: COM CPU-2

Refer to <LED on the CPU-DK module> in “1. CA-54board”.

<Switch on the CPU-DK module> : COM CPU-1: COM CPU-2

Refer to <Switch on the CPU-DK module> in “1. CA-54board”.

S103 (A-2) : Unit ID setting switch for LANSets the unit ID for connecting LAN. Do not change thesetting.Factory setting :Bit 1 : ONBits 2 to 8 : OFF

S104 (A-4) : Monitor reset switch for the mainCPUUsed for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the mainCPU control terminal pin (CN103).

S401 (A-1) : System reset switchPressing this switch activates the system-reset and thesystem restarts.

S402 (A-1) : CA-CPU reset switchPressing this switch resets the CA-54CFB board.

S403 (B-1): Switch setting the number of thepower supply unitsSets the number of the power supply units that are requiredfor this unit. Do not change the setting.Factory setting:Bits 1 and 2: ONBits 3 and 4: OFF

S901 (A-4) : Monitor reset switch for the COM CPU-1Used for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the COMCPU-1 control terminal pin (CN503).

S902 (A-4) : Modes setting switch for the COM CPU-1Sets the modes of the COM CPU-1, but this switch iscurrently not in use. Factory setting is all OFF.

S1101 (A-4) : Monitor reset switch for the COM CPU-2Used for maintenance purpose. Pressing this switch resetsthe system while maintaining this unit through the COMCPU-2 control terminal pin (CN703).

S1102 (A-4) : Modes setting switch for the COMCPU-2Sets the modes of the COM CPU-2, but this switch iscurrently not in use. Factory setting is all OFF.

Page 25: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-15MFS-2000 IM

<LED on the DIF-130 board> : PC cardD1 (A-1) : DETECT ALit when a compact flash is inserted correctly into socketA.

D2 (A-1) : DETECT BLit when a compact flash is inserted correctly into socketB.

D3 (A-1) : +++++3.3 V+3.3 V power supply status indication.Lit when +3.3 V power is supplied.

D4 (A-1) : ACTIVE ALit or flashes during communication with the compactflash in socket A.

D5 (A-1) : ACTIVE BLit or flashes during communication with the compactflash in socket B.

D6 (A-1) : CD (Card Detect) status LEDLit when the DIF-130 board is inserted into the parentboard correctly.

D7 (A-1) : GPO status LEDThis switch is currently not in use.

<LED on the SG-272 board>Refer to <LED on the SG-272 board> in “1. CA-54board”.

Page 26: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-16 MFS-2000 IM

3. DVP-30 board

A side/Component side

MAIN CPUModule*1

MAIN CPUModule*

A B C D E F G H J K

D504D501D502D505D503D506

S901

S1201D1204D1203D1202D1201

D703D702D701

ND1101ND1102

S801

S1101

ND1201ND1202

D1104D1103D1102D1101D1004D1002D1003D1001

1

2

3

4

5

6

7

8GFEDCBA

65

43

21

D12D18D19

D10D13

D14D15D16D17

SW2

SW1

CPU-DR Module

GFEDCBA

65

43

21

D11D13D14D18

D17D16D15D19

SW1

SW2

CPU-DT Module

<LED>D501 (A-2) : +++++3.3 V+3.3 V power supply status indication.Lit when +3.3 V power is supplied.

D502 (A-2) : +++++2.5 V-1+2.5 V-1 power supply status indication.Lit when +2.5 V-1 power is supplied.

D503 (A-3) : +++++1.5 V-1+1.5 V-1 power supply status indication.Lit when +1.5 V-1 power is supplied.

D504 (A-2) : +++++12 V+12 V power supply status indication.Lit when +12 V power is supplied.

***** : The CPU-DR module or CPU-DT module is used in the Main CPU module.

Page 27: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-17MFS-2000 IM

D505 (A-2) : +++++2.5 V-2+2.5 V-2 power supply status indication.Lit when +2.5 V-2 power is supplied.

D506 (A-3) : +++++1.5 V-2+1.5 V-2 power supply status indication.Lit when +1.5 V-2 power is supplied.

D701 (A-5) : BUS A status LEDLit when CPU A accesses the FPGA.

D702 (A-5) : BUS B status LEDLit when CPU B accesses the FPGA.

D703 (A-5) : READ status LEDLit when CPU A or B makes the read access to the FPGA.

D1001 (A-7) : BOOT DONE status LEDLit when IC108 starts up.

D1002 (A-7) : DLKD status LEDLit when the DLL (Delay Locked Loop) of the FPGA islocked. If the LED does not light, the FPGA may bedefective.

D1003 (A-7) : RCB DONE status LEDLit when the FPGA configuration is complete.

D1004 (A-7) : SYSTEM status LEDLit when configuration is complete and FPGA reset is alsocomplete. If the LED does not light, the FPGA may bedefective.

D1101 (A-7) : DGB 7 A status LEDUsed for design purpose.

D1102 (A-7) : DGB 6 A status LEDUsed for design purpose.

D1103 (A-7) : DGB 5 A status LEDUsed for design purpose.

D1104 (A-7) : DGB 4 A status LEDUsed for design purpose.

D1201 (A-4) : DGB 7 B status LEDUsed for design purpose.

D1202 (A-4) : DGB 6 B status LEDUsed for design purpose.

D1203 (A-4) : DGB 5 B status LEDUsed for design purpose.

D1204 (A-4) : DGB 4 B status LEDUsed for design purpose.

ND1101 (A-6), ND1102 (A-6) : STATUS A LEDThe status indication of the CPU A on the DVP-30 board.

ND1201 (A-3), ND1202 (A-3) : STATUS B LEDThe status indication of the CPU B on the DVP-30 board.

<Switch>S801 (A-6) : CPU A CONFIG switchUsed for maintenance purpose.

S901 (A-4) : CPU B CONFIG switchUsed for maintenance purpose.

S1101 (A-7) : SETUP A switchUsed for maintenance purpose.

S1201 (A-4) : SETUP B switchUsed for maintenance purpose.

<LED on the CPU-DR module>Refer to <LED on the CPU-DR module> in “1. CA-54board”.

<Switch on the CPU-DR module>Refer to <Switch on the CPU-DR module> in “1. CA-54board”.

<LED on the CPU-DT module>Refer to <LED on the CPU-DT module> in “1. CA-54board”.

<Switch on the CPU-DT module>Refer to <Switch on the CPU-DT module> in “1. CA-54board”.

Page 28: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-18 MFS-2000 IM

A side/Component side

4. MIX-48 board

MAIN CPUModule*

A B C D E F G H J K

1

2

3

4

5

6

7

8

D410

D409

D308

D204

D208

D304

SL1SL2SL3

S401S2702

D3704D3702D3705D3703D3701

IF-937

GFEDCBA

65

43

21

D12D18D19

D10D13

D14D15D16D17

SW2

SW1

CPU-DR Module

GFEDCBA

65

43

21

D11D13D14D18

D17D16D15D19

SW1

SW2

CPU-DT Module

***** : The CPU-DR module or CPU-DT module is used in the Main CPU module.

Page 29: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-19MFS-2000 IM

<Switch>S401 (A-5) : MIX-CPU reset switchPressing this switch initializes the CPU on the MIX-48 board.

S2702 (A-5) : Monitor reset switchUsed for maintenance purpose.This is a reset switch used in maintaining through theterminal pin (CN2001).

<Slit land>SL1, SL2 (A-4), SL3 (A-5) : JTAG chain switchingThey are the slit lands that are used to switch the JTAGchains. Connect these slit lands to open or to close them sothat the following statuses can be obtained.

SL1 SL2 SL3 Status

Short Open Open The chain of CPLD only is established.

Open Short Short All of the JTAG devices are connectedin chain.

<LED on the CPU-DR module>Refer to <LED on the CPU-DR module> in “1. CA-54board”.

<Switch on the CPU-DR module>Refer to <Switch on the CPU-DR module> in “1. CA-54board”.

<LED on the CPU-DT module>Refer to <LED on the CPU-DT module> in “1. CA-54board”.

<Switch on the CPU-DT module>Refer to <Switch on the CPU-DT module> in “1. CA-54board”.

<LED>D204, D208, D304 (A-3) : +++++1.5 V-1 to 3+1.5 V-1 to 3 power supply status indication.Lit when the +1.5 V-1 to 3 power is supplied each.

D308 (A-3) : +++++2.5 V+2.5 V power supply status indication.Lit when the +2.5 V power is supplied.

D409 (A-2) : +++++3.3 V+3.3 V power supply status indication.Lit when the +3.3 V power is supplied.

D410 (A-2) : +++++12 V+12 V power supply status indication.Lit when the +12 V power is supplied.If this LED does not light, the fuse may have blown.

D3701 (A-6): CONFIG. ERROR status LEDIndicates the configuration error of the FPGA.If this LED lit, the FPGA can possibly be working incor-rectly.

D3702, D3704, D3705 (A-6): C2, C1 and C0 statusLEDIndicates the status of CPU on the circuit board.

D3703 (A-6): PLL UNLOCK status LEDIndicates lock/unlock of the PLL (Phase Locked Loop) inthe FPGA.If this LED lit, the PLL can possibly be unlocked.

Page 30: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-20 MFS-2000 IM

5. MY-112 board

A side/Component side

MAIN CPUModule*

IF-937

IF-937

A B C D E F G H J K

1

2

3

4

5

6

7

8

D410

D409

D304D308

D204D208

S401S3601D2603D2604D2605D2601D3602

SL2D3501

D3801D3802

SL1

SL3

(CC-95)GFEDCBA

65

43

21

D12D18D19

D10D13

D14D15D16D17

SW2

SW1

CPU-DR Module

GFEDCBA

65

43

21

D11D13D14D18

D17D16D15D19

SW1

SW2

CPU-DT Module

***** : The CPU-DR module or CPU-DT module is used in the Main CPU module.

Page 31: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-21MFS-2000 IM

<LED>D204, D208 (A-3) : +++++1.5 V-1, 2+1.5 V power supply status indication.Lit when the +1.5 V-1 and 2 power is supplied respectively.

D304, D308 (A-3) : +++++2.5 V-1, 2+2.5 V power supply status indication.Lit when the +2.5 V-1 and 2 power is supplied respectively.

D401 (A-2) : +++++12 V+12 V power supply status indication.Lit when the +12 V power is supplied.If this LED does not light, the fuse may have blown.

D409 (A-2) : +++++3.3 V+3.3 V power supply status indication.Lit when the +3.3 V power is supplied.

D2601 (A-6) : PLL UNLOCKIndicates lock/unlock of the PLL (Phase Locked Loop) inthe FPGA.If this LED lit, the PLL can possibly be unlocked.

D2602 (A-6) : CONFIG. ERRORIndicates the configuration error of the FPGA.If this LED lit, the FPGA can possibly be working incor-rectly.

D2603, D2604, D2605 (A-6) : C2, C1 and C0 statusLEDIndicates the status of CPU on the circuit board.

D3501 (A-4) : CCR EXTLit when the CC-95 board is inserted.

D3801 (A-5) : FM_DATA ACT status LEDFM_DATA Ethernet communication status indication.Lit while the data transmission or reception is in progress.

D3802 (A-5) : FM_DATA 100 status LEDFM_DATA Ethernet communication speed status indica-tion.

Lit : 100 Mb/sNot lit : 10 Mb/s

<Switch>S401 (A-5) : MY-CPU reset switchPressing this switch initializes the CPU on the MY-112board.

S3601 (A-6) : Monitor reset switchThis is a reset switch used in maintaining through theterminal pin.

<Slit land>SL1 (A-4), SL2 (H-5) and SL3 (A-5) : JTAG chainswitchingThey are the slit lands that are used to switch the JTAGchains. Connect these slit lands to open or to close them sothat the following statuses can be obtained.

SL1 SL2 SL3 Status

short open open The chain of CPLD only isestablished.

open short short All of the JTAG devices areconnected in chain.

<LED on the CPU-DR module>Refer to < LED on the CPU-DR module > in “1. CA-54board”.

<Switch on the CPU-DR module>Refer to < Switch on the CPU-DR module > in “1. CA-54board”.

<LED on the CPU-DT module>Refer to <LED on the CPU-DT module> in “1. CA-54board”.

<Switch on the CPU-DT module>Refer to <Switch on the CPU-DT module> in “1. CA-54board”.

Page 32: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-22 MFS-2000 IM

6. XPT-24 board

A B C D E F G H J K L M N P Q1

2

3

4

5

6

7

8

9

10

11

12

13

D801D8

D12

D13

D7

S1701

S1601D1701D1405

D1404D1403

D1402D1401

SL1101SL1100

SL1102

IF-937

F

E

D

C

B

A

1 2 3 4 5

DI1

DI4

DI2

DI3

DI6

DI7

DI8

SW1

SW2

CPU-DKModule

(COM CPU)

A side/Component side

D1401 (A-10) : CONFIG. ERROR status LEDIndicates the configuration error of the FPGA.If this LED is lit, the FPGA can possibly be workingincorrectly.

D1402 (A-10) : PLL UNLOCK status LEDIndicates lock/unlock of the PLL (Phase Locked Loop) inthe FPGA. If this LED is lit, the PLL can possibly beunlocked.

D1403, D1404, D1405 (A-9, A-10) : C0, C1, C2status LEDIndicates the status of CPU on the circuit board.

D1701 (B-9) : RESET status LEDSystem reset status indication.Lit when S1701 is pressed or the power voltage drops to+3.3 V.

<LED>D7 (A-4) : +++++1.5 V+1.5 V power supply status indication.Lit when the +1.5 V power is supplied.

D8 (A-3) : +++++12 V+12 V power supply status indication.Lit when +12 V power is supplied.If the LED does not light, the fuse may have blown.

D12 (A-3) : +++++3.3 V+3.3 V power supply status indication.Lit when +3.3 V power is supplied.

D13 (A-4) : +++++2.5 V+2.5 V power supply status indication.Lit when +2.5 V power is supplied.

D801 (P-3) : +++++5 V+5 V power supply status indication.Lit when +5 V power is supplied.

Page 33: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

2-23MFS-2000 IM

<Switch>S1601 (A-9) : MONITOR reset switchUsed for maintenance purpose.This is a reset switch used in maintaining through theterminal pin (CN1602).

S1701 (A-9) : XPT-CPU reset switchPressing this switch initializes the CPU on the XPT-24board.

<Slit land>SL1100, SL1101, SL1102 (B-6) : JTAG chainswitchingThey are the slit lands that are used to switch the JTAGchains.Connect these slit lands to open or to close them so that thefollowing statuses can be obtained.

SL1101 SL1100 SL1102 Status

short short open The chain of CPLD only isestablished.

short open short All of the JTAG devices areconnected in chain.

<LED on the CPU-DK module>Refer to <LED on the CPU-DK module> in “1. CA-54board”.

<Switch on the CPU-DK module>Refer to <Switch on the CPU-DK module> in “1. CA-54board”.

Page 34: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...
Page 35: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-1MFS-2000 IM

Section 3Installation of the Control Panel

3-1. Installation Space

3-1-1. External Dimensions

Control panel MKS-2010

Unit : mm

FRAME

ON

KEY2KEY1

ON

MIXCOLOR

CUTTRANS

AUTO

EFFMIX

KEY2KEY1BKGD

PRIOR

KEY

PST

GPIEDIT AUXSAFE

TITLE

BORD

SHDW

CROP

LIGHT REV

EDGE

N/R

TRAIL

1CHEFF

SOFT

BVLD

CTR

POS2CHEFF

SET

DIAG

MENUTOP

FILE

UP

REG

STOP

IN2

IN5IN3IN1 IN2 IN4 IN6 IN7VIDEO

INTFM1IN8

COLOR

BKGDBLACK

IN1 IN3IN2 IN4 IN5 IN6 IN7 IN8 FM1INT

VIDEO

COLOR

BKGDBLACK

XPT

HOLDSHIFT

KEY1 M/E PGMCCR2CCR1KEY2 DSK1 DSK2

UTILAUX1 AUX2 AUX3 AUX4EDIT

PVWKEY SHIFT

MEM

XP/KY

HOLDBUS

SRC

IN3IN1BLACK IN4 IN5 IN6 IN7 FM1INT

VIDEO

COLOR

BKGDIN8

PRE

MACRO

POST

MACRO

ATTCH

ENBLJOGSHTL

ALL STARTDEV1 DEV2 PLAY STOP CUE

TC

FTB

M/E

MACROSTORE

TRANS

RATE

ALL

EFFAUTO

TRNS DISS

7 8 9

4 5 6

1 2 3

10

SHOT

SNAP

/WIPE

EFF

BANK

SEL

ON ON

AUTO

TRANS

AUTO

TRANS

DSK1 DSK2

DSK

PVW

440

20.5

100

180

5.5

349.

7

103

20.581.6109.8 215.2

88.3152.6

38.1

260

12.1

324.

237

9.2

7

384

Page 36: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-2 MFS-2000 IM

IN2 IN3IN1BLACK

BKGD

COLOR

VIDEO

INTFM1IN8IN2 IN7IN3 IN5IN4 IN6

FRAME

BLACK IN1

IN4 IN5 IN6 IN7

XPT

HOLDSHIFT

KEY1 M/E PGMCCR2CCR1KEY2 DSK1 DSK2

IN1

UTILAUX1 AUX2 AUX3 AUX4EDIT

PVW KEY SHIFT

COLOR

FM1INT

VIDEO

COLOR

BKGD

PST

BLACK IN3IN1 IN2 IN4 IN5 IN6

KEY

PRIOR

BKGD KEY1 KEY2

MIX EFF

PST

KEY1 KEY2

AUTO

TRANSCUT

AUTO

TRANS

AUTO

TRANS

COLORMIX ON ON

ON ONIN7 IN8

MEM

XP/KY

FM1INT

IN3IN2 IN4 IN5 IN6 IN7 IN8 FM1INT

VIDEO

COLOR

BKGD

VIDEO

COLOR

BKGDM/E

BLACK

M/EAUTO

TRANS

AUTO

TRANS

DSK1

IN1

DSK2

DSK

IN3

PVW

FTB

IN2 IN4 IN5 IN6 IN7

MIX

IN8 FM1INT

VIDEO

WIPE

COLOR

BKGD

STOP

PRE

MACRO

POST

MACRO

AUTO

TRANSCUT

IN8

HOLD

MIX

SHIFTXPT

HOLD

ATTCH

ENBLJOGSHTL

ALL STARTDEV1 DEV2 PLAY STOP CUE

TC

BLACK

BUS

SRC

GPIEDIT AUXSAFE

TITLE

BORD

SHDW

CROP

LIGHT REV

EDGE

N/R

TRAIL

1CHEFF

SOFT

BVLD

CTR

POS2CHEFF

SET

DIAG

MENUTOP

FILE

UP

REG

P/PWIPE

/PP

M/E

MACROSTORE

TRANS

SEL

BANK

EFF

/WIPE

SNAP

10

321

654

RATE

SHOT

987

DISSTRNS

AUTO EFF

ALL

68.1

260

42.1

324.

240

9.2

443.

6

160.8220.8

85.720.5

137.

927

4.5

103

20.581.6

109.9

35.6440

7

384Unit : mm

Control panel MKS-2015

Page 37: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-3MFS-2000 IM

UP

FILE

TOPMENU

DIAG

SET

EFF2CH

POS

CTR

BVLD

SOFT

EFF1CH

TRAIL

N/R

EDGE

REVLIGHT

CROP

SHDW

BORD

TITLE

SAFEAUXEDIT GPI

SRC

BUS

TCCUESTOPPLAYDEV2DEV1

STARTALLSHTL JOG

ENBL

ATTCH

HOLD

XPTSHIFT

MIX

HOLD

IN8

CUTTRANS

AUTO

MACRO

POST

MACRO

PRE

STOP

WIPE

MIX

FTB

PVW

DSK

DSK2DSK1

TRANS

AUTO

TRANS

AUTO

XP/KY

MEM

ONON

ONONMIXCOLOR

TRANS

AUTO

TRANS

AUTOCUT

TRANS

AUTO

KEY2KEY1

PST

EFFMIX

KEY2KEY1BKGD

PRIOR

KEY

PST

BKGD

COLOR

VIDEO

INTFM1

COLOR

SHIFTKEYPVW

EDITAUX4AUX3AUX2AUX1 UTIL

DSK2DSK1KEY2 CCR1 CCR2 PGMM/EKEY1

SHIFTHOLD

XPT

IN7IN6IN5IN4

FRAME

BLACK IN1 IN3IN2

IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16

IN16IN15IN14IN13IN12IN11IN10IN9

IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16

IN16IN15IN14IN13IN12IN11IN10IN9

M/E

M/EBLACKBKGD

COLOR

VIDEO

INTFM1IN8IN7IN6IN5IN4IN2 IN3IN1

BLACKBKGD

COLOR

VIDEO

INTFM1IN8IN7IN6IN5IN4IN2 IN3

BLACKBKGD

COLOR

VIDEO

INTFM1IN8IN7IN6IN5IN4IN2 IN3IN1

BLACKBKGD

COLOR

VIDEO

INTFM1IN8IN7IN6IN5IN4IN2 IN3IN1

IN1

ALL

EFFAUTO

TRNS DISS

7 8 9

SHOT

RATE

4 5 6

1 2 3

10

SNAP

/WIPE

EFF

BANK

SEL

TRANS

STORE MACRO

M/E

/PP

WIPEP/P

REG

IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16

68.1

260

42.1

324.

240

9.2

443.

6

160.8220.8

85.720.5

137.

927

4.5

103

20.581.6

109.9

35.6592

7

384Unit : mm

Control panel MKS-2017

Page 38: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-4 MFS-2000 IM

Unit : mm

3-1-2. Installation Space

When the control panel is recessed into a control console or similar, make holes as shown below into thecontrol console with the following dimensions.

Control panel MKS-2010

50 o

r m

ore

120 or more

(35)

1535

30 or more30 or more

450

481465

177.

831

1.2

402.

739

.4

6-M5

Page 39: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-5MFS-2000 IM

Control panel MKS-2015

Unit : mm

50 o

r m

ore

120 or more

(35)

1535

30 or more30 or more

450

481465

177.

831

1.2

446.

739

.4

8-M5

384.

1

Page 40: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-6 MFS-2000 IM

Control panel MKS-2017

Unit : mm

50 o

r m

ore

120 or more

(35)15

35

30 or more

602617633

8-M5

311.

217

7.8

446.

739

.438

4.1

(465.6)

Page 41: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-7MFS-2000 IM

3-2. Removing/Reinstalling Front Panel

nWhen removing/reinstalling the front panel, be sure tounplug the power cord, and confirm that the power is off.

Removal1. Remove the two screws and remove the front panel.

Reinstallation1. Install the front panel by reversing the removal steps.

Front panelB3 x 5

(This illustration shows MKS-2010.)

Page 42: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-8 MFS-2000 IM

Blank panel

3-3. Installing the Options

The following option is available for the control panel.

Options for the control panel

Model name

HK-PSU11

POWER SUPPLY UNIT

3-3-1. Installing HK-PSU11

The HK-PSU11 is used in the control panel.nBefore installing the HK-PSU11, be sure to unplug thepower cord, and confirm that the power is off.

1. Remove the screw which secures the release lever.

Release lever

B3 x 5

Release lever

2. Turn the release lever counterclockwise.

3. Remove the blank panel.

nStore the removed blank panel in a safe place.

Page 43: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-9MFS-2000 IM

nRemoval1. Remove the screw which secures the release lever.2. Turn the release lever in either of the following

direction.To remove the HK-PSU11 on slot A : 2To remove the HK-PSU11 on slot B : 3

3. Remove the HK-PSU11.

Guide

Guide

Guide

HK-PSU11

HK-PSU11

HK-PSU11

Release lever

Slot A

Slot B

Slot ASlot BB3 x 5

4. Insert the HK-PSU11 securely along the guides.

5. Secure the release lever with the screw removed instep 1 to lock the HK-PSU11.

Page 44: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-10 MFS-2000 IM

S106 S107 S108S100 S103

D103 D102 D100D101

D107 D106 D104D105

S101 S104

D111 D110 D108D109

D115 D114 D112D113

D132-D147

S102 S105

D119 D118 D116D117

D123 D122 D120

D130

D128

D126

D124

D131

D129

D127

D125

D121

D148-D163 D164-D179

1

A B C D E

2

3-4. Description of On-board Switches and LEDs

nThe number shown in the parentheses ( ) indicates the address on the circuit board.

FP-141 board

A side/Component side

<LED>D100 to D103 (B-1) : MAIN CPU status LEDMain CPU status indication.Used only for production in the assembly factory.

D104 (B-1) : SIO ACTFlashes while the communication with the equipment thatis connected to the EDITOR PANEL connector is inprogress.

D105 (B-1) : SBUS ACTLit while the communication with the equipment that isconnected to the REMOTE connector is in progress.

D106 (B-1) : LAN ACTLit while the communication between the main CPUmodule and the MPU-302B board is in progress.

D107 (B-1) : LAN 100MLit while the 100 Mb/s communication with MENU CPUis in progress.

D108 (C-1) to D115 (B-1) : C01 to C08CTRL connector communication IC status indication.Used only for production in the assembly factory.

D116 (D-1) to D123 (C-1) : C11 to C18PERIPH connector communication IC status indication.Used only for production in the assembly factory.

D124 (D-2) : SBUS CH1Lit when an equipment is connected to the REMOTEconnector.

D125 (D-2) : SBUS RUNDisplays the status of the circuit for processing a signal inthe REMOTE connector. Lit during a normal operation.

D126 (D-2) : SBUS TXFlashes while transmitting the communication data to anequipment that is connected to the REMOTE connector.

D127 (D-2) : SBUS RXFlashes while receiving the communication data from theequipment that is connected to the REMOTE connector.

D128 (D-1) : HDLit when the reference signal that is input via the REF INconnector is an HD signal.

D129 (D-1) : REF OKREF IN signal presence/absence status indication.Lit when the reference signal is input via the REF INconnector.

D130 (D-1) : MCONFIGLit when the direct configuration mode is performed.Used only for production in the assembly factory.

D131 (D-1) : USERUsed only for production in the assembly factory.

D132 to D147 (B-2) : MAIN CPU status LEDMain CPU module status indication.Displays the initialization steps of the main CPU at power-on.“A0” is displayed when the initialization is completed andthe main CPU is booted correctly.

D148 (C-2) to D163 (B-2) : COM0 CPU status LEDCTRL LAN control IC status indication.Displays the initialization steps of the COM0 CPU atpower-on. LED flashes rotatively when the initialization iscompleted and the COM0 CPU is booted correctly.

D164 (D-2) to D179 (C-2) : COM1 CPU status LEDPERIPH LAN control IC status indication.Displays the initialization steps of the COM1 CPU atpower-on. LED flashes rotatively when the initialization iscompleted and the COM1 CPU is booted correctly.

Page 45: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-11MFS-2000 IM

<Switch>S100 (B-1) : MAIN RESET switchReset switch for the entire this control panel.

S101 (B-1) : C0-RESET switchIndependent reset switch for the CTRL LAN control IC.

S102 (C-1) : C1-RESET switchIndependent reset switch for the PERIPH LAN control subCPU.

S103 (B-1) : Monitor reset switch for the main CPUReset switch that is used during maintenance of the mainCPU from the TERMINAL pin (CN101).

S104 (C-1) : Monitor reset switch for the COM0 CPUReset switch that is used during maintenance of the CTRLLAN control IC from the TERMINAL pin (CN102).

S105 (D-1) : Monitor reset switch for the COM1 CPUReset switch that is used during maintenance of thePERIPH LAN control IC from the TERMINAL pin(CN103).

S106 (A-1) : Unit ID setting switch for LANSets the unit ID for connecting LAN. Do not change thesetting.Factory setting :Bit 1 : OFFBits 2 to 8 : ON

S107 (A-1) : Group ID setting switch for LANSets the group ID for connecting LAN.Factory setting and in standard use :Bit 1 : OFFBits 2 to 8 : ON

S108 (A-1) : STATION IDSets the station ID for connecting SBUS. Used to connectthe external routing switcher to the REMOTE connector.Factory setting :Bit 1 and bits 3 to 8 : ONBit 2 : OFF

( indicates a knob position.)

12345678

12481632CTRLDATA

1248163264128

ON

12345678

1248163264128

ON

12345678

ON

UNIT IDS106

GROUP IDS107

STATION IDS108

3-5. Installing on the Control Console

3-5-1. MKS-2010

cBe sure to install the control panel on the control consoleby more than two persons. Installing it by one person maycause backache.

The following parts supplied with the control panel arerequired to install the control panel on the control console.. Rack angle assembly (L) (R). Blank panel. Screw B4 x 14 (six). Screw B5 x 8 (six). Screw B3 x 6 (four)

1. Remove the six screws (B4 x 6) of the control panel.2. Remove the screws (B3 x 4) from the rack angle

assembly (L) and the rack angle assembly (R) respec-tively, and remove the rack angle cover (L) and therack angle cover (R).

Rack angle assembly (R)Rack angle assembly (L)

Rack angle cover (L)

Rack angle cover (R)

Control panel

B4 x 6

B4 x 6

B3 x 4

B3 x 4

Page 46: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-12 MFS-2000 IM

3. Install the rack angle assembly (L) and the rack angleassembly (R) on the control panel using the suppliedsix screws (B4 x 14).

4. Install the blank panel on the rack angle assemblieswith the supplied four screws (B3 x 6).

B4 x 14

B4 x 14

Rack angle assembly (R)

Rack angle assembly (L)

Control panel

5. Install the control panel on the control console with thesupplied six screws (B5 x 8).

6. Install the rack angle cover (L) and the rack anglecover (R) removed in step 2 on the rack angle assem-bly (L) and the rack angle assembly (R) respectively.nFit the covers on the rear side first and push them onthe front side lightly to install.

7. Tighten the rack angle cover (L) and the rack anglecover (R) using the screws removed in step 2.

Blank panel

B3 x 6

B3 x 6

Rack angle assembly (R)

Rack angle assembly (L)

B5 x 8B5 x 8

Control console

Control panel

B3 x 4

B3 x 4

Rack angle cover (L)

Rack anglecover (R)

Rear side

Front sideRack angle cover

Page 47: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

3-13MFS-2000 IM

3-5-2. MKS-2015/2017

cBe sure to install the control panel on the control consoleby more than two persons. Installing it by one person maycause backache.

The following parts supplied with the control panel arerequired to install the control panel on the control console.. Rack angle assembly (L) (R). Blank panel. Screw B4 x 14 (six). Screw B5 x 8 (six). Screw B5 x 16 (two)

1. Remove the six screws (B4 x 6) of the control panel.2. Remove the screws (B3 x 4) from the rack angle

assembly (L) and the rack angle assembly (R) respec-tively, and remove the rack angle cover (L) and the rackangle cover (R).

3. Install the rack angle assembly (L) and the rack angleassembly (R) on the control panel with the supplied sixscrews (B4 x 14) .

B3 x 4

B3 x 4

B4 x 6

B4 x 6

Rack angle assembly (R)Rack angle assembly (L)

Rack angle cover (L)

Rack angle cover (R)

Control panel

B4 x 14

B4 x 14

Rack angle assembly (R)

Rack angle assembly (L)

Control panel

4. Install the control panel on the control console with thesupplied six screws (B5 x 8).

5. Install the rack angle cover (L) and the rack anglecover (R) removed in step 2 on the rack angle assem-bly (L) and the rack angle assembly (R) respectively.nFit the covers on the rear side first and push them onthe front side lightly to install.

6. Tighten the rack angle cover (L) and the rack anglecover (R) using the screws removed in step 2.

7. Install the blank panel on the control console with thesupplied two screws (B5 x 16).

B5 x 8B5 x 8

Control panel

Control console

B5 x 16

B3 x 4

B3 x 4

Blank panel

Rack angle cover (L)

Rack angle cover (R)

Rear side

Front side Rack angle cover

(The illustration shows MKS-2015.)

Page 48: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...
Page 49: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-1MFS-2000 IM

Section 4Connection

4-1. Matching Connectors and Cables

Use the following connectors, cables or equivalents when connecting cables to the unit.

Model name Panel indication Connector name Matching connector and cable

Name Sony part No.

MFS-2000 REF IN BNC, 75 Z Belden 8281 coaxial _

REF OUT cable

EDITOR D-sub 9-pin, Female D-sub 9-pin, MaleSERIAL TALLY . Connector 9-pin, Male 1-560-651-00*1

TERMINAL . Junction Shell 9-pin 1-561-749-00

GPI D-sub 25-pin, Female D-sub 25-pin, MaleTALLY . Connector 25-pin, Male 1-560-904-11*1

. Junction Shell 25-pin 1-563-377-11

DATA RJ-45 modular jack*2_ _

CTRL

IN 1 to 8 BNC, 75 Z Belden 8281 coaxial _

OUT 1 to 4 cableor5CFB coaxial cable _

(HDTV system)

MKS-2110M IN 1 to 8 BNC, 75 Z Belden 8281 coaxial _

OUT 1 to 4 cableor5CFB coaxial cable _

(HDTV system)

MKS-2440 FM DATA RJ-45 modular jack*2_ _

FM DEVICE IEEE1394 6-pin _ _

MKS-2010 GPI D-sub 25-pin, Female D-sub 25-pin, MaleMKS-2015 . Connector 25-pin, Male 1-566-356-11*1

MKS-2017 . Junction Shell 25-pin 1-563-377-11

EXT DISPLAY D-sub Miniature 15-pin, Use the display cable thatFemale is commercially available

on market.

EDITOR PANEL D-sub 15-pin, Female D-sub 15-pin, Male _

. Connector 15-pin, Male

. Junction Shell 15-pin

REMOTE BNC, 75 Z BNC, 75 Z _

REF IN Belden 8281coaxial cable

CTRL RJ-45 modular jack*2_ _

PERIPHDATA

DEVICE USB Type A Use the cable supplied or thereceptacle USB cable (with plug) that is

commercially available onmarket. (5 m or less)

*1 : The following crimp contact is required for the plug.AWG#18 to #22 : 1-566-493-21AWG#22 to #24 : 1-564-774-11AWG#24 to #30 : 1-564-775-11

*2 : Conforms to the IEEE 802.3 Ethernet 100BASE-TX standards.

Page 50: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-2 MFS-2000 IM

_ EXT VIEW _

15

69

113

1425

_ EXT VIEW _

+V

GPI OUT n B

GPI OUT n A

GPI OUT 5-8

GPI OUT COM

n : 1-4

<Relay>

<Open collector output>

(*4)

(*5)

GPI : (D-sub 25-pin, Female)INPUT x 8, TTLOUTPUT x 4, relay contacts 30 V 0.1 A (resistive load)OUTPUT x 4, open collector, 30 V rated voltage

Pin No. Signal name Function

1 GND Ground

2 GND Ground

3 GPI IN 2 General-purpose input

4 GPI IN 4

5 GPI IN 6

6 GPI IN 8

7 GPI OUT 1B General-purpose relay

8 GPI OUT 2B output (B) (*4)

9 GPI OUT 3B

10 GPI OUT 4B

11 GPI OUT 6 General-purpose open collector

12 GPI OUT 8 output (*5)

13 GPI OUT COM Ground for open collectoroutput

14 GND Ground

15 GPI IN 1 General-purpose input

16 GPI IN 3

17 GPI IN 5

18 GPI IN 7

19 GPI OUT 1A General-purpose relay

20 GPI OUT 2A output (A) (*4)

21 GPI OUT 3A

22 GPI OUT 4A

23 GPI OUT 5 General-purpose open

24 GPI OUT 7 collector output (*5)

25 GPI OUT COM Ground for open collector output

nA and B of the same number constitute a pair of relaycontacts.

_ EXT VIEW _

15

69

4-2. Input/Output Signals of Connectors

The input/output signals of the connectors at the rear panelare as follows.GPI, DATA, and CTRL connectors are used in both theproccessor and control panel. The input/output signal ofthese connectors used in the processor is same as that ofthe control panel.

TERMINAL : RS-232C (D-sub 9-pin, Female) to Terminal

Pin No. Signal name Function

1 DCD Data carrier detect (*1)

2 RXD Received data

3 TXD Transmitted data

4 DTR Data terminal ready (*1)

5 GND Ground

6 DSR Data set ready (*1)

7 RTS Request to send (*2)

8 CTS Clear to send (*2)

9 _ _

(*1) : Pins 1, 4 and 6 are internally connected together on the CN-2345board.

(*2) : Pins 7 and 8 are internally connected together on the CN-2345 board.

EDITOR, SERIAL TALLY : RS-422A (D-sub 9-pin,Female)<DEVICE> (*3) from External Devices

Pin No. Signal name Function

1 FG Frame ground

2 TX_ Transmitted data (_)

3 RX+ Received data (+)

4 GND Common ground

5 _ No connection

6 GND Common ground

7 TX+ Transmitted data (+)

8 RX_ Received data (_)

9 _ No connection

(*3) <DEVICE> : A controlling device

Page 51: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-3MFS-2000 IM

TALLY : (D-sub 25-pin, Female)OUTPUT x 4, relay contacts 30 V 0.1 A(resistive load)OUTPUT x 4, open collector, 30 V rated voltage

Pin No. Signal name Function

1 GND Ground

2 GND Ground

3 _ No use

4 _

5 _

6 _

7 TALLY OUT 1B TALLY relay output (B)(*6)

8 TALLY OUT 2B

9 TALLY OUT 3B

10 TALLY OUT 4B

11 TALLY OUT 6 TALLY open collector output (*7)

12 TALLY OUT 8

13 TALLY OUT COM Ground for open collector output

14 GND Ground

15 _ No use

16 _

17 _

18 _

19 TALLY OUT 1A TALLY relay output (A)(*6)

20 TALLY OUT 2A

21 TALLY OUT 3A

22 TALLY OUT 4A

23 TALLY OUT 5 TALLY open collector output (*7)

24 TALLY OUT 7

25 TALLY OUT COM Ground for open collector output

nA and B of the same number constitute a pair of relaycontacts.

+V

TALLY OUT n B

TALLY OUT n A

TALLY OUT 5-8

TALLY OUT COM

n : 1-4

<Relay>

<Open collector output>

(*6)

(*7)

113

1425

_ EXT VIEW _

FM DEVICE : IEEE1394 (6-pin)

Pin No. Signal name Function

1 VP Cable power (No use)

2 VG Cable ground

3 TPB_ Strobe on receive,Data on transmit (_)

4 TPB+ Strobe on receive,Data on transmit (+)

5 TPA_ Data on receive,Strobe on transmit (_)

6 TPA+ Data on receive,Strobe on transmit (+)

DATA, CTRL, PERIPH, FM DATA :100BASE-TX, RJ-45 (8-pin)

Pin No. Signal name Function

1 TX+ Transmitted data (+)

2 TX_ Transmitted data (_)

3 RX+ Received data (+)

4 _ No connection

5 _ No connection

6 RX_ Received data (_)

7 _ No connection

8 _ No connection

1 8

_ EXT VIEW _

2 4 6

1 3 5

_ EXT VIEW _

Page 52: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-4 MFS-2000 IM

EXT DISPLAY : (High-density D-sub 15-pin, analogRGB, Female) to External Display

Pin No. Signal name Function

1 RED Video red

2 GREEN Video green

3 BLUE Video blue

4 _ No connection

5 GND Ground

6 GND Ground

7 GND Ground

8 GND Ground

9 _ No connection

10 GND Ground

11 _ No connection

12 _ No connection

13 HSYNC Horizontal sync

14 VSYNC Vertical sync

15 _ No connection

EDITOR PANEL: RS-422A (D-sub 15-pin, Female)<CONTROLLER>*8

Pin No. Signal name Function

1 GND Ground

2 RX_ Received data (_)

3 TX+ Transmitted data (+)

4 GND Ground

5 _ No connection

6 +12V +12V

7 +12V +12V

8 +12V +12V

9 _ No connection

10 RX+ Received data (+)

11 TX_ Transmitted data (_)

12 GND Ground

13 GND Ground

14 GND Ground

15 GND Ground

(*8) <CONTROLLER> : A controlling device

_ EXT VIEW _

15

1115610

EXT VIEW

18

915

DEVICE : USB Type A

Pin No. Signal name Function

1 +5V USB Vcc

2 D_ USB_

3 D+ USB+

4 GND Ground

Page 53: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-5MFS-2000 IM

4-3. System Connection

A

CTRL PERIPHEXT DISPLAY EDITOR PANELDEVICEDATA GPIREF IN REMOTE

DATA CTRL EDITOR SERIAL TALLY GPIREF IN

IN

1 2 3 4 5 6 7 8 21 3 4

1 2 3 4 5 6 7 8 21 3 4

DATA CTRL TERMINAL TALLYREF OUT

1

8

9

18

A

B

CAC IN

AC ININ

OUT

OUT

DATA CTRL

DATA CTRL

EDITOR

CTRL

DATA

REMOTE

PERIPH

PERIPHReference video signal b)

Ethernet switch a)

MKS-2010/2015/2017 Control Panel

BKS-R Series

HDS-X Series

Reference video signal b)

Reference video signal b)

Cross cable

Cable with BNC connectors

MFS-2000 Multi Format Switcher Processor

Ethernet switch a)

VTR DDR

Output video signal c)

(Main line output/REC VTR/Monitor etc.)

DCU-8000 Device Control Unit Pack

a) It is recommended that the CTRL and DATA LAN networks be configured by connecting separate Ethernet switches for each LAN. Depending on the type of Ethernet network, a single Ethernet switch can perform comparably to multiple switches.

b) Terminate with the supplied 75 Z terminators. Terminators are supplied in the product package.

c) This unit provides two output connectors for each output. If you will be using only one of the connectors, terminate the other with a 75 Z terminator. Terminators are not supplied with the unit.

Material video signal (camera/VTR etc.)

BVE-9100 Editing Control System

Page 54: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

4-6 MFS-2000 IM

4-4. Setup

Settings such as the signal format setting and output signalassignment are required before using the MFS-2000-Csystem.

Refer to the User’s Guide for details.

Page 55: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

5-1MFS-2000 IM

Section 5Service Overview

5-1. Troubleshooting

5-1-1. Processor

The main power of the processor cannot beturned on. (Indicator does not light green.)

The monitor picture is not displayed correctly.

The main power of the processor cannot be turned on. (Indicator does not light green.)

Are more than two POWER switches among A, B, and C of the processor turned ON?

Set more than two POWER switches among A, B, and C of the processor to ON.

Is the power cord of the processor connected correctly?

The power supply unit is probably defective.

Connect it correctly.

YES

NO

NO

YES

A picture is not displayed on the monitor screen even though the main power ofthe processor is turned on.

Are the standard boards installed into the specified slots?

Install the standard boards into the specified slots. (Refer to MFS-2000-C Maintenance Manual.)

Are the option boards installed into the specified slots?

Are the input and output cables connected correctly?

Install the option boards into the specified slots. (Refer to Section 2-3.)

YES

Is the software installed correctly?

YES

The MFS-2000 is probably defective.

YES

NO

NO

Install the software correctly.(Refer to the User’s Guide.)

NO

Check connections of the input and output equipment.

NO

YES

Page 56: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

5-2 MFS-2000 IM

5-1-2. Control Panel

The main power cannot be turned on.(Indicator does not light green.)

The main power of the control panel cannot be turned on. (Indicator does not light green.)

Connect it correctly.

Is the power cord of the control panel connected correctly?

The power supply unit is probably defective.

NO

YES

Check the previously described diagram “The main power of the control panel cannot be turned on”.

The control panel is probably defective.

Nothing is displayed on the menu monitor screen.

Is the power of the control panel turned on?

Is the switch on the control panel lit?

. The backlight is probably burnt out.

. LCD or the LCD drive circuit is probably defective.

YES

NO

NO

YES

Nothing is displayed on the menu monitor screen.

LEDs and other indicators do not light.

Connect the LAN cable.

LEDs and other indicators do not light.

Is the power of the control panel turned on?

Is the CTRL LAN cable connected to the processor (CTRL)?

Control panel is probably defective.

Check the previously described diagram “The main power of the control panel cannot be turned on”.YES

YES

NO

NO

Page 57: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

5-3MFS-2000 IM

FanProcessor is air-cooled by the fans (on both sides).If dust has accumulated in the intake of the fan, air isprevented from flowing smoothly and this may result in atemperature rise inside the machine. This may have anadverse effect on performance and the life of the machine.Cleaning of the fan every month is recommended.Contact your local Sony Sales Office/Service Center forinformation on cleaning the fan.

5-2. Periodic Inspection and Maintenance

5-2-1. Cleaning

Processor

FilterThe filter on the rear of the front panel can easily accumu-late the dust. Be sure to remove dust by cleaning asfollows.1. Remove the front panel. (Refer to Section 2-2.)2. Remove the dust accumulated on the filter with a

vacuum cleaner.nCleaning the filter by washing in water is recommend-ed when there is a heavy accumulation of dust.Be sure to dry the filter completely after it has beenwashed.

Filter

Fan

Fan

Control panel

FilterThe filter on the rear of the bracket can easily accumulatedust. Be sure to remove dust by cleaning as follows.

1. Remove the screw and remove the bracket.2. Remove dust accumulated on the filter with a vacuum

cleaner.nCleaning the filter by washing in water is recommend-ed when there is a heavy accumulation of dust.Be sure to dry the filter completely after it has beenwashed.

FanControl panel is air-cooled by the fans (on both sides). Ifdust has accumulated in the intake of the fan, air is pre-vented from flowing smoothly and this may result in atemperature rise inside the machine. This may have anadverse effect on performance and the life of the machine.Cleaning of the fan every month is recommended.Contact your local Sony Sales Office/Service Center forinformation on cleaning the fan.

B3 x 5

Filter

Bracket

Fan

Front side

Page 58: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

5-4 MFS-2000 IM

5-3. Data Backup Capacitor

A large capacitor is installed on the CA-54/CA-54CFBboard in order to retain the data such as the resume data,snapshots, and effects in the MFS-2000 series machine.Leave the main power of the MFS-2000 series turned onfor two hours or longer in order to charge this capacitor.The data is retained for about three days when the capaci-tor is fully charged under normal operating temperatureand humidity. However, this period may vary dependingon the storage environment. Be sure to save necessary datain an external media.

Page 59: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

MFS-2000 IM

The material contained in this manual consists ofinformation that is the property of Sony Corporation.Sony Corporation expressly prohibits the duplication ofany portion of this manual or the use thereof for anypurpose other than the operation or maintenance of theequipment described in this manual without the expresswritten permission of Sony Corporation.

Le matériel contenu dans ce manuel consiste eninformations qui sont la propriété de Sony Corporation.Sony Corporation interdit formellement la copie dequelque partie que ce soit de ce manuel ou son emploipour tout autre but que des opérations ou entretiens del’équipement à moins d’une permission écrite de SonyCorporation.

Das in dieser Anleitung enthaltene Material besteht ausInformationen, die Eigentum der Sony Corporation sind.Die Sony Corporation untersagt ausdrücklich dieVervielfältigung jeglicher Teile dieser Anleitung oder denGebrauch derselben für irgendeinen anderen Zweck alsdie Bedienung oder Wartung der in dieser Anleitungbeschriebenen Ausrüstung ohne ausdrücklicheschriftliche Erlaubnis der Sony Corporation.

Page 60: SWITCHER PROCESSOR PACK MFS-2000-C IM MKS8210A … · user can turn off the power in case a fault ... This manual is the installation manual of Switcher Processor Pack MFS-2000 ...

Printed in Japan

Sony Corporation 2005. 8 16

©2004

MFS-2000-C (SY) E

3-838-833-03