Surprise, surprise, failed graft.
description
Transcript of Surprise, surprise, failed graft.
Copyright © 2012 Idondivi, Inc. All rights reserved.
Categories ; Posterior, Grafting, Multiple Implants, Nobel Biocare
2 Copyright © 2012 Idondivi, Inc. All rights reserved
Patient reports loss of two molars about 1 year ago
3 Copyright © 2012 Idondivi, Inc. All rights reserved
Molar site appears to have grafting material
4 Copyright © 2012 Idondivi, Inc. All rights reserved
Mandibular canal identified on PA radiograph
5 Copyright © 2012 Idondivi, Inc. All rights reserved
Two implants planned
6 Copyright © 2012 Idondivi, Inc. All rights reserved
# 19 site # 18 site
7 Copyright © 2012 Idondivi, Inc. All rights reserved
BLP’s placed in relation to bone volume, bone width and screw retained crowns.
8 Copyright © 2012 Idondivi, Inc. All rights reserved
BLP’s lock in the bucco-lingual and shoulder of the implants
9 Copyright © 2012 Idondivi, Inc. All rights reserved
Mesio-Distal ideal positioning
10 Copyright © 2012 Idondivi, Inc. All rights reserved
BLP’s overlap sufficiently, radiograph is diagnostic , no need for correction, so 0-
degree rotation blocks ( green) are indicated
11 Copyright © 2012 Idondivi, Inc. All rights reserved
Poor integration of graft material.
12 Copyright © 2012 Idondivi, Inc. All rights reserved
# 18 site prepared for 8.5 mm implant
13 Copyright © 2012 Idondivi, Inc. All rights reserved
# 18 , a 1.5 mm alveolectomy planned due to a pointy ridge. Note defect in # 19
site
14 Copyright © 2012 Idondivi, Inc. All rights reserved
Due to failed bone graft, osteotomy has to be increased from planned 8.5 mm to
created adequate initial stability. 10 mm osteotomy ( 23 – 10 = 13 – red flexistop
@ 3 = 10 MM )
15 Copyright © 2012 Idondivi, Inc. All rights reserved
11.5 mm osteotomy
16 Copyright © 2012 Idondivi, Inc. All rights reserved
11.5 mm osteotomy, decision is made to increase to 13 mm, due to safe distance
to mandibular canal
17 Copyright © 2012 Idondivi, Inc. All rights reserved
Note large defect around osteotomy # 19
18 Copyright © 2012 Idondivi, Inc. All rights reserved
Prep and placement of 4.3 x 8.5 Nobel Active implant # 18 site. Using Astra
Facilitate drills.
19 Copyright © 2012 Idondivi, Inc. All rights reserved
13 x 4.3 MM Nobel Active for # 19 site
20 Copyright © 2012 Idondivi, Inc. All rights reserved
4-5 mm of implant exposed, buccal and lingual cortical plates are intact.
21 Copyright © 2012 Idondivi, Inc. All rights reserved
Grafting with “ Socket Graft Putty”
22 Copyright © 2012 Idondivi, Inc. All rights reserved
Covered with Resorbable collagen membrane for covered healing
23 Copyright © 2012 Idondivi, Inc. All rights reserved
Implants placed in planned position, only # 19 is 4.5 mm longer to created
adequate initial stability