Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”,...

4
Surgitron DUAL RF 120 4.0 MHz Radiofrequency Technology ® Patented Surgitron ® Dual RF™ unit with advanced CutSURE™ RF technology provides unparalleled surgical control, precision, versatility and safety

Transcript of Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”,...

Page 1: Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37. 3. Data on file.

Surgitron DUAL RF™

1204.0 MHz Radiofrequency Technology

®

Patented Surgitron® Dual RF™

unit with advanced CutSURE™ RF

technology provides unparalleled

surgical control, precision,

versatility and safety

Page 2: Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37. 3. Data on file.

Incorporate precision, versatility, and safety across a wide range of gynecologic procedures regardless of setting- private office, surgery center, or hospital.

Digital Control PanelEasy operation and clear view of settings

Safety IndicatorsProvides visual and auditory alerts for added safety

Dual Frequency Monopolar (4.0MHz) and Bipolar (1.7 MHz) for outstanding precision & control across a wide variety of procedures

Small footprintEasy to integrate into the office setting

Solid State CircuitryDependable & consistent energy emission

Parameter Recallenables rapid set-up

Wide variety of hand pieces & tipsVersatile to accommodate a wide variety of procedures and preferences

* as compared to Bovie® 1250 & Valleylab® Force FX in porcine tissues

Common Procedures: • LEEP/LLETZ • Labiaplasty • Biopsy for pathology• Condyloma • Vaginal Polyps • Bipolar coagulation• Vaginal Cysts • Skin Lesions

CutSURE™ Precision Cutting Technology• Enables micro-smooth incisions in thin, mobile, or tension-free

tissues for excellent results with minimal scar tissue• 73% less thermal spread compared to competitors* for

maximum readability of histologic specimens• Less burning or charring of tissues for quick recovery and

decreased post-operative pain

Surgitron® Dual RF™ 120

Page 3: Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37. 3. Data on file.

Fullly Filtered (Cut)Micro-smooth cutting • Negligible lateral heat • Minimal cellular destruction • Ideal for skin incision and biopsy • Best cosmetic results 6,7

Full Rectified (Blend)Cutting with hemostasis • Ideal for subcutaneous tissue dissection and planing • Especially useful in vascular areas while producing minimal amounts of lateral heat and tissue damage

Partially Rectified (Coag)Coagulation / Shrinkage • Ideal for hemostasis with controlled penetration • For cutting with maximum hemostatic control

BipolarPinpoint, micro-coagulation • Minimum charring or tissue necrosis • Ideal for coagulation in and around critical anatomy

FulgurationMaximum hemostasis • Ideal for intentional tissue destruction

5 DISTINCT WAVEFORMS Offer Optimal Clinical Outcomes Across a Wide Range of Procedures

Minimize Lateral Thermal Spread and Maximize Precision

0

0.25

0.50

0.75

1.00

Transmission electron microscopy showing lateral thermaldamage on human oviducts by different instruments

Source: Olivar, AC, et al, Ann Clin Lab Sci. 1999 Oct-Dec; 29(4): p281-5.

Electro-cautery

KTP-532Laser

Nd-YAGLaser

CO2Laser

Exte

nt o

f Tis

sue

Dam

age

in m

m

Source: Golio, JM, et al, “RF and Microwave Applications and Systems,”The RF and Microwave Handbook, p21-2.

Frequency (MHz)

Tiss

ue P

enet

ratio

n De

pth

(cm

)

1

250

200

150

100

50

0 10 1000.1

Electro-surgery

of the lateral thermal damage versus most lasers1/2 to 1/3 the lateral thermal damage compared

to conventional electrosurgery1/3

Page 4: Surgitron - HOLOGICNiamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37. 3. Data on file.

HOW OUR PATENTED RADIOFREQUENCY TECHNOLOGY WORKSCellular Radiofrequency Absorption

STEP 1High frequency RF energy has a strong affinity for water.

STEP 2Targeted tissue/cell readily absorbs energy due to high water content.

STEP 3Intracellular pressure increases as water molecules expand.

STEP 4Volatilization results in cell conversion to vapor. Process emits steam which aids in coagulation.

STEP 5Cellular interaction enables meticulous precise dissection with tissue preservation.

For more information, contact your Hologic Surgical Sales Rep at 508-263-2471, Option 2

Trusted Partners

By partnering with Hologic’s CynoSure Ellman team which has over 50 year of experience in the radiofrequency technology Hologic GYN Surgical Solutions can provide you with an even greater suite of minimally invasive treatment options for women facing gynecologic conditions that affect their comfort, health, and well-being

Ordering & Product Codes

Description Part #

Surgitron® Dual RF™/120 IECShipped complete with: Powercord, Dual Footswitch & Cable, IEC Foot Controlled Handpiece, IEC 3-Button Fingerswitch Handpiece, IEC Neutral Plate & cables, Medical Electrode Set, Bipolar Forceps, and Instruction Manual

IEC3A-S30

Optional Disposables, for complete offerings visit www.Ellman.com

IEC Disposable Neutral Plate-Standard Size (25 PCS) IEC-NPD

Medical Electrode Single Use SetAssortment of 8 styles, RF electrodes, available in 1/16" Shaft Only (40 pcs per pack)Includes 5 of each electrode: A2D, A8D, B1D, B2D, C3D, D8D, E3D, F1D

DSEP40

Empire® microlncision™ Needle Electrodes 1/16", Length 3cm, straight (2 PCS) TEE301

LLETZ Electrodes Assortment Single Use SetAssortment of 5 styles, LLETZ electrodes, available in 1/16" Shaft (5 pcs per pack) Includes 1 of each electrode: W1D, W2D, W3D, F2D, W18D

W4D

Conization Electrode™ Resuable G1

External Genital Lesion RF Electrodes™ Resuable SetAssortment of 4 styles, Includes 1 of each electrode: W16, W17, W18, W19

W15

Clinical Citations

1. High frequency RF surgery minimizes burning of tissue, unlike laser or conventional electrosurgery. Olivar, AC, et al, Ann. Clin. Lab Sci. (1999); 29 (4): p281-5. 2. Niamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37.3. Data on file.4. Botero, G.E.S, J Otol Head Neck Surgery (1996); vol 24 (1), p69.5. Aferzon, M, Derm Surgery (2002); vol 28, p735-738.6. With less tissue destruction, healing is accelerated and patients can recover quickly. Bridenstine, J.B.,

Derm Surgery (1998); vol 24, p397-400.7. High frequency RF surgery causes less trauma7. Ericsson, E, et al, The Laryngoscope (2007); vol 117, p654.8. Minimal Heat Dissipation. Silverman, EB, et al, Veterinary Surgery (2007); vol 36, p50-56.

921-7035-004 Rev. 001 © Hologic 2018. All rights reserved. Printed in USA. Specifications are subject to change without prior notice. Hologic and The Science of Sure and associated logos are trademarks and/or registered trademarks of Hologic, Inc. and/or its subsidiaries in the United States and/or other countries. All other trademarks and registered trademarks are the property of their respective owners.