Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in...

4
Surgical kit for guided implantology

Transcript of Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in...

Page 1: Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in diameters 4.15 mm and 5.50 mm. These allow working with a smaller inter-implant distance

Surgical kit for guided implantology

Page 2: Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in diameters 4.15 mm and 5.50 mm. These allow working with a smaller inter-implant distance

h 9 mm

Optimised master sleevesThe kit instruments are guided inside sleeves available in

diameters 4.15 mm and 5.50 mm. These allow working with a smaller inter-implant distance and with less space occupied in the oral cavity when inserting implants up to

4.10 mm in diameter.

Fundamental measurementsThe surgical instruments contained in this kit respect some fundamental measurements in order to be guided precisely inside the sleeves used by the manufacturers of surgical stents according to the clinical plan studied and planned on the computer. The sleeves are oriented according to predetermined axes and a fixed height (of 9 mm) with respect to the level of the crestal bone.

STOPS with safe screwingThe STOPS are screwed onto the drills in the shank→tip, direction, thus avoiding the possibility of their accidentally slipping off. The STOPS are interchangeable, so that, while the hole that is to be prepared is of the same length, they can be used with drills of any diameter.

Just one kit, two systems, many software programsA single kit compatible with the main software programs for guided surgery that can be fitted either for Premium cylindrical implants with an internal hexagon or for Outlink2 cylindrical implants with an external hexagon.

Dedicated drill systemThe drills, cylindrical and with a spiral shape, are

distinguished by a double ring which guides the diameter and height of the preparation. The white ring identifies drills for long preparation, the black

ring refers to drills for short preparation.

Easy colour-coded recognitionThe colour code marked on the implant vial and the surgical cover screw also identifies the drills and the ECHO PLAN mounters. The mounters also allow the final insertion of the implant to be guided, not only in terms of the angle and height, but also in the orientation of the connection hexagon.

Premium

Page 3: Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in diameters 4.15 mm and 5.50 mm. These allow working with a smaller inter-implant distance

LONg driLLSSHOrT driLLSMuCOTOMES

STOP fOr LONg PrEPArATiON

STOP fOr SHOrT PrEPArATiON

(SLEEVE 5.50 MM ø)

(SLEEVE 4.15 MM ø)

AdAPTErdyNAMOMETriC rATCHET

dEViCES fOr rEMOViNg THE STOPS

iNiTiAL driLLS

BONE PrOfiLErS

driVEr fOr MOuNTErS

HANd driVErS fOr CONNECTiNg SCrEwS

rigHT ANgLE driVEr

rATCHET driVErS

(SLEEVE 4.15 MM ø)

(SLEEVE 5.50 MM ø)

HANd kNOB fOr MOuNTEr

dedicated accessories for the Outlink2 system

(present in the ZEgSurgEryB* assortment)

dedicated accessories for the Premium system

(present in the ZAgSurgEryB* assortment)Premium

Composition of the surgical kit

MOuNTErS

BONE TAPS

COuNTErSiNk driLLS

MOuNTErS

BONE TAPS

driVErS fOr TAP SCrEwS

COuNTErSiNk driLLS

Page 4: Surgical kit for guided implantology...The kit instruments are guided inside sleeves available in diameters 4.15 mm and 5.50 mm. These allow working with a smaller inter-implant distance

D - I M P - E C H O P L A N - E

Surgical trays and integrations

Sweden & Martina S.p.A.Via Veneto, 1035020 Due Carrare (PD), ItalyTel. +39.049.9124300Fax +39.049.9124290

[email protected]

Sweden & Martina Mediterranea S.L.Sorolla Center, Oficina 504Avda Cortes Valencianas 58, 5pl46015-Valencia, EspañaTel. +34.96.3525895

[email protected] gratuito 900993963

Sweden & Martina Deutschland GmbHc/o Mader & StadlerRupert-Mayer-Str. 46D - 80539 München

[email protected] 08001830964

The instruments and kits in this catalogue manufactured by Sweden & Martina S.p.A. are Medical Devices. They are produced in compliance with the UNI EN ISO 9001:2008 (ISO 9001:2008) and UNI CEI EN ISO 13485:2012 (ISO 13485:2003) standards and are certified with the CE Mark (Class I) and CE 0476 mark (Class IIA and Class IIB) in compliance with European Medical Device Directive No. 93/42/CEE and European Directive No. 2007/47/CEE.

The contents are up to date at the time of publication. Check with the company for any later updates. Rev. 06-13

As well as the surgical components common to both implant systems, the ECHO PLAN kit contains a section dedicated to instruments only for Premium implants (specific bone taps, mounters and countersink drills for inserting Premium implants) and a section dedicated to instruments only for Outlink2 implants (specific bone taps, mounters and countersink drills for inserting Outlink2 implants). The ECHO PLAN kit must be ordered complete with the instruments for one of the two systems; the instruments necessary for the other system can be ordered separately.All the common instruments in the kit can also be ordered separately as spare parts.

Code description

ZAGSURGERYB*

ECHO PLAN kit for Premium implants

ZEGSURGERYB*

ECHO PLAN kit for Outlink2 implants

GS-A-INTEGRA

integration of dedicated instruments for the Premium system

GS-E-INTEGRA

integration of dedicated instruments for the Outlink2 system

GSURGERYB*-TRAY

Autoclavable instrument tray in radel