SupremeSprinkler Pipes & Fittings
Presentation
The Supreme Industries Ltd
SUPREMEHDPE Sprinkler Pipes and Fittings
Supreme Sprinkler………. Sprinkler system is a system where you can spray water through nozzles, at
rate which is less than absorption capacity of soil. This system and it joints consists of pipes and fittings made up of HDPE. Water use can be optimized to get maximum benefits out of it, by means of this system. Supreme HDPE pipes and fittings accessories are designed and developed by experts, to provide you the best quality .
SUPREME HDPE pipes and fittings are useful for all kinds of soils. It is useful where land is not leveled. By applying water through the sprinkler system, water can be saved ,soil erosion can be prevented / reduced, temperature of plant area can be maintained in summer. All the plants get uniform and regular water, so plant growth is uniform and fast. The crop gets ready earlier compared to others. Quality of crop remains uniform, and production is more. Thus you get better income and reduced cost.
Application : Suitable for almost all field crops like Wheat, Gram, Pulses as well as
Vegetables, Cotton, Soya bean, Tea, Coffee, and other fodder crops. Suitable for Residential, Industrial, Hotel, Resorts, Public & Government
Enterprises, Golf Links, Race courses. Salient Features : Portable , Chemically inert, Easy Handling, Quick installation, Corrosion
resistant, Flexible and tough, Low labour, Protection from ultra violet rays.
DATA SHEET for Sprinkler Irrigation System: A. Raw Material Requirement Reference
Designation (MRS) 6.3, 8.0 & 10 Mpa at 20ºC IS;14151(pt-1); 1999
Melt Flow Rate (I5) 0.2 to 1.10 Gm/10 min. at 190º C IS;14151(pt-1); 1999
Density 940.4 to 958.4 Kg/cm3 IS;14151(pt-1); 1999
B. Dimension As per table IS;14151(pt-1); 1999
Length 3.0 to 6.0m or as agreed between manufacturer and
Purchaser.IS 14151 (pt-1): 1999
Visual Appearance (Surface Finish) Satisfactory IS 14151 (pt-1): 1999
C. Performance Requirement
Heat Reversion Test Max 3% IS 14151 (pt-1): 1999
Hydrostatic Pressure Resistance Test
QUALITY TEST IS 14151 (pt-1): 1999
Duration: 165 hrs. at 80ºC, Stress Values : 3.5 Mpa
ACCEPTANCE TEST
Duration : 48 hrs at 80º C ,Stress Values: 3.8 Mpa
Fusion Compatibility Test QUALITY TEST IS 14151 (pt-1): 1999
Duration: 165 hrs at 80º C, Stress Values : 3.5 Mpa
ACCEPTANCE TEST
Duration : 48 hrs 80º C, Stress Values : 3.8 Mpa
Melt Flow Rate (I5) 0.2 to 1.10 (both inclusive) Gm/10 min. IS 2530 : 1963
DATA SHEET for Sprinkler Irrigation System: Carbon Black Content & Dispersion 2.5 ± 0.5% IS 2530 : 1963
Tensile Test 19 Mpa(T/S) 500%(Elongation) IS 14151 (pt-1): 1999
Workmanship and Appearance Satisfactory IS 14151 (pt-2): 1999
Bearing Capacity of Holding Attachment The holding attachment is strong enough to withstand the pressure two times the working pressure of pipe.
IS 14151 (pt-2): 1999
Leakage Test without leakage IS 14151 (pt-2): 1999
Hydraulic Proof Test The assembly shall not show any sign of localized swelling, leakage, weeping or deformation and shall not burst during the test.
IS 14151 (pt-2): 1999
Weldability Test QUALITY TEST IS 14151 (pt-2): 1999
Duration: 165 hrs. at 80ºC Stress Values : 3.5Mpa
ACCEPTANCE TEST
Duration : 48 hrs at 80ºC Stress Values: 3.8 Mpa
D. Identification & Marking Colour: Black. All pipes shall be indelibly marked by hot foil embossing as per Colour code
IS 14151: 1999
Class-1-----Orange
Class-2------Red
Class-3------Blue
Class-4-------Green
Supreme Sprinkler pipes comply to IS 14151-Part I & Part II ,
Class 1( 0.25 Mpa ) - IS 14151 : 1999
Sr. No.
OD(mm) Avg(mm). Thickness(mm) Avg(mm).
Min Max OD Min Max Thickness
1 75.00 75.70 75.35 2.00 2.40 2.20
2 90.00 90.80 90.40 2.20 2.60 2.40
3 110.00 111.00 110.50 2.70 3.20 2.95
4 125.00 126.20 125.60 3.10 3.60 3.35
5 140.00 141.30 140.65 3.50 4.10 3.80
6 160.00 161.50 160.75 3.90 4.50 4.20
7 180.00 181.70 180.85 4.40 5.00 4.70
8 200.00 201.80 200.90 4.90 5.60 5.25
Supreme Sprinkler pipes comply to IS 14151 Part I & Part II :
Class 2( 0.32 Mpa ) - IS 14151 : 1999
Sr. No.
OD(mm) Avg(mm). Thickness(mm) Avg(mm).
Min Max OD Min Max Thickness
1 63.00 63.60 63.30 2.00 2.40 2.20
2 75.00 75.70 75.35 2.50 2.90 2.70
3 90.00 90.80 90.40 2.90 3.40 3.15
4 110.00 111.00 110.50 3.40 3.90 3.65
5 125.00 126.20 125.60 3.80 4.50 4.15
6 140.00 141.30 140.65 4.30 5.00 4.65
7 160.00 161.50 160.75 4.90 5.60 5.25
8 180.00 181.70 180.85 5.50 6.30 5.90
9 200.00 201.80 200.90 6.10 7.00 6.55
Supreme Sprinkler pipes comply to IS 14151 Part I & Part II
Class 3( 0.4 Mpa ) - IS 14151 : 1999
Sr. No.
OD(mm) Avg(mm). Thickness(mm) Avg(mm).
Min Max OD Min Max Thickness
1 50.00 50.50 50.25 2.00 2.40 2.20
2 63.00 63.60 63.30 2.50 2.90 2.70
3 75.00 75.70 75.35 3.00 3.40 3.20
4 90.00 90.80 90.40 3.50 4.10 3.80
5 110.00 111.00 110.50 4.20 4.80 4.50
6 125.00 126.20 125.60 4.80 5.50 5.15
7 140.00 141.30 140.65 5.40 6.10 5.75
8 160.00 161.50 160.75 6.20 7.00 6.60
9 180.00 181.70 180.85 6.90 7.80 7.35
10 200.00 201.80 200.90 7.70 8.70 8.20
Supreme Sprinkler pipes comply to IS 14151 Part I & Part II
Class 4( 0.6 Mpa ) - IS 14151 (Part 1) : 1999
Sr. No.
OD(mm) Avg(mm). Thickness(mm) Avg(mm).
Min Max OD Min Max Thickness
1 40.00 40.40 40.20 2.30 2.80 2.55
2 50.00 50.50 50.25 2.90 3.40 3.15
3 63.00 63.60 63.30 3.80 4.40 4.10
4 75.00 75.70 75.35 4.50 5.20 4.85
5 90.00 90.80 90.40 5.30 6.10 5.70
6 110.00 111.00 110.50 6.50 7.40 6.95
7 125.00 126.20 125.60 7.40 8.30 7.85
8 140.00 141.30 140.65 8.30 9.30 8.80
9 160.00 161.50 160.75 9.40 10.60 10.00
10 180.00 181.70 180.85 10.60 11.90 11.25
11 200.00 201.80 200.90 11.80 13.20 12.50
Sprinkler Piping System Layout Design
THANK YOU………..