Supplementary Materials Increasing ankle push-off work with a powered prosthesis does not necessarily reduce metabolic rate for transtibial amputees Roberto E. Quesada 1 , Joshua M. Caputo 1,2 , and Steven H. Collins 1,3 1. Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 2. Human Motion Technologies L.L.C., Pittsburgh, PA 3. Robotics Institute, Carnegie Mellon University, Pittsburgh, PA S1. Supplementary Methods S1.1 Description of the ankle-foot prosthesis emulator We used an experimental ankle-foot prosthesis emulator to systematically vary ankle push-off in isolation from other prosthesis features. We previously described this system in detail, including complete designs and code (Caputo & Collins, 2014a). We provide a brief overview here. The system has three main elements: (1) powerful off-board motor and controller, (2) a tether transmitting mechanical power and sensor signals, (3) a lightweight instrumented end-effector worn by the participant (Fig. S1). This division of components maximizes responsiveness and minimizes end- effector mass during treadmill walking. A powerful, low-inertia electric motor and a high-speed, real-time controller provide off-board actuation. Motor voltage is regulated using an industrial motor drive with embedded velocity control. Desired motor velocity commands are generated using the real-time controller. The transmission consists of a Bowden cable with a coiled-steel outer conduit and synthetic inner rope. The cable causes minimal interference with normal leg motions (Caputo & Collins, 2014a). Figure S1. Photograph of the ankle-foot prosthesis end-effector.

Transcript of Supplementary Materials Increasing ankle push-off work...

Page 1: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Supplementary Materials

Increasing ankle push-off work with a powered prosthesis does not

necessarily reduce metabolic rate for transtibial amputees

Roberto E. Quesada1, Joshua M. Caputo

1,2, and Steven H. Collins

1,3

1. Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA

2. Human Motion Technologies L.L.C., Pittsburgh, PA

3. Robotics Institute, Carnegie Mellon University, Pittsburgh, PA

S1. Supplementary Methods

S1.1 Description of the ankle-foot prosthesis emulator

We used an experimental ankle-foot prosthesis emulator to systematically vary ankle push-off in

isolation from other prosthesis features. We previously described this system in detail, including

complete designs and code (Caputo & Collins, 2014a). We provide a brief overview here.

The system has three main elements: (1) powerful off-board motor and controller, (2) a tether

transmitting mechanical power and sensor signals, (3) a lightweight instrumented end-effector worn by

the participant (Fig. S1). This division of components maximizes responsiveness and minimizes end-

effector mass during treadmill walking.

A powerful, low-inertia electric motor and a high-speed, real-time controller provide off-board

actuation. Motor voltage is regulated using an industrial motor drive with embedded velocity control.

Desired motor velocity commands are generated using the real-time controller. The transmission

consists of a Bowden cable with a coiled-steel outer conduit and synthetic inner rope. The cable causes

minimal interference with normal leg motions (Caputo & Collins, 2014a).

Figure S1. Photograph of the ankle-foot prosthesis end-effector.

Page 2: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

The Bowden cable transmission pulls on the pulley, sprocket, chain and leaf-spring, in series, producing

an ankle plantarflexion torque between the frame and forefoot. The pulley–sprocket component

magnifies transmission forces and allows direct measurement of spring deflection. A tensioning spring

keeps the chain engaged. A pyramidal adapter attaches to the pylon worn by the user. A dorsiflexion

spring comprised of rubber bands retracts the toe during leg swing. Fiberglass leaf springs provide series

elasticity for ankle torque measurement and control. A separate leaf spring directly connected to the

frame (not the toe) comprises the heel.

Prosthesis dimensions approximate those of an average human foot (Hawes & Sovak, 1994). The

distance between the heel and the toe is 0.22 m. The heel is 0.07 m to the rear of the pylon. The ankle is

0.07 m from the ground plane during standing. The toe is 0.07 m wide and the heel is 0.04 m wide,

slightly narrower than the typical human dimensions of 0.10 and 0.07 m, respectively. Rubber pads at

the toe and heel contact points approximate the effects of the sole of a walking shoe. The prosthesis end-

effector weighs 1.2 kg.

Ankle rotation and pulley rotation are measured with encoders. Ankle torque is computed based on

measurements of spring displacement and ankle position using a calibrated model. During calibration

trials the prosthesis is fixed upside down while masses of known weight are hung from the toe. A range

of masses and ankle angles that span the expected operating conditions are applied. Ankle torque is then

modeled as a function of ankle angle and prosthesis pulley angle, with coefficients that minimize

squared error during regression.

Torque control is achieved using proportional feedback on torque error, with damping injection on

motor velocity to improve stability and iteratively learned feedforward compensations to improve torque

tracking (Zhang et al., 2015). A similar feedback control law is used to perform ankle position control

during the swing phase of walking, substituting a position error for torque error and using a modified

gain.

Prosthetic ankle joint work was regulated using impedance control in two phases. In each phase, joint

torque was controlled as a function of ankle angle. The Dorsiflexion phase began at heel contact and

lasted until the velocity of the ankle joint reversed direction, usually around 75% of the stance period,

when the prosthesis switched into the Plantarflexion phase. Dorsiflexion phase behavior was constant

across conditions, while the torque profile in the Plantarflexion phase was adjusted to achieve desired

levels of net prosthesis work rate. This changed work production during ankle push-off without altering

other aspects of prosthesis function. Nominal parameters were selected to emulate the behavior of the

biological ankle during normal walking at the same speed, in the manner of Caputo & Collins (2014b).

Safety features limit the forces exerted by the prosthesis on the human user. Software places limits on

the maximum commanded torque. An electrical plantarflexion limit switch and electrical buttons

accessible to the subject and experimenter deactivate the motor when pressed. A transmission break-

away, composed of an empirically determined number of loops of thin synthetic rope, provide a

mechanical failsafe.

Page 3: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

S1.2. Additional details of motion capture and inverse-dynamics analysis methods

Reflective markers were placed on the sacrum, left and right anterior superior iliac spine, left and right

greater trochanter, medial and lateral epicondyles of the knee, medial and lateral malleoli of the ankle,

third metatarsophalangeal joint of the toe, and posterior calcaneus of the heel. On the prosthesis-side

limb, markers were placed in locations approximating these landmarks on the socket and prosthesis.

With the prosthesis emulator, the medial and lateral aspects of the forefoot axis of rotation were used in

place of the medial and lateral malleoli of the ankle.

Joint angles were calculated using a standard Euler angle approach. Segment reference frames were

defined according to the position of bony landmarks and joint angles were extracted from the linear

transformation matrix that described the rotation from one coordinate system to another.

The foot coordinate system was defined by markers at the medial and lateral malleoli of the ankle, the

third metatarsophalangeal joint of the toe, and the posterior calcaneus of the heel. The primary axis of the

foot segment was defined as the vector connecting the midpoint of the ankle markers to the ankle marker

on right side of the body segment. For the left leg, this was the medial ankle marker and for the right leg

this was the lateral ankle marker. The secondary axis was defined as the cross product of the primary

vector with the vector from the heel to the toe markers. The tertiary axis was defined as the cross product

of the primary and secondary axes.

The shank coordinate system was defined by markers at the medial and lateral malleoli of the ankle and

the medial and lateral epicondyles of the knee. The primary axis of the shank segment was defined in the

same manner as the primary axis of the foot segment: as the vector connecting the midpoint of the ankle

markers to the ankle marker on the right side of the body segment. The secondary axis was defined as the

cross product of the primary vector with a vector drawn from the center of the ankle markers to the center

of the knee markers. The tertiary axis was defined as the cross product of the primary and secondary axes.

Ankle plantarflexion-dorsiflexion angles and moments were calculated about the shared primary axis of

the foot and shank. Note that this choice of a shared primary axis disallows the measurement of rotation of

the foot relative to the shank in the frontal and coronal planes. We opted for simplified foot marker

placements to improve marker tracking while capturing the sagittal ankle rotations accurately. This

simplification has negligible impact on inverse dynamics analysis, because both the movement and

rotational inertia of the foot about these axes is very small (de Lava, 1996). To obtain accurate

measurements of all foot and ankle degrees of freedom would require substantially more markers and

model assumptions.

The thigh coordinate system was defined by markers at the medial and lateral epicondyles of the knee

and the trochanters of the left and right hips. The primary axis of the thigh segment was defined as the

vector connecting the midpoint of the knee markers to the knee marker on the right side of the body

segment. The secondary axis was defined as the cross product of the primary vector with a vector from

the center of the knee markers to the hip marker. The tertiary axis was defined as the cross product of

the primary and secondary axes. Knee flexion-extension angles and moments were calculated about the

primary axis of the thigh.

Page 4: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

The pelvis coordinate system was defined by markers placed on the left and right greater trochanters,

sacrum, and left and right sides of the anterior superior iliac spine. The primary axis of the pelvis

segment was defined as the vector connecting the midpoint of the hip markers to the hip marker on the

right side of the body. The tertiary axis was defined as the cross product of the primary vector with the

vector drawn from the sacrum to the midpoint of the anterior superior iliac spine markers. The

secondary axis was defined as the cross product of the tertiary and primary axes. Hip flexion-extension

angles and moments were calculated about the primary axis of the pelvis.

Joint angles and moments were later inverted, as necessary, to conform to standard gait analysis

conventions (Winter, 1991): Ankle angles were defined as positive for dorsiflexion and negative for

plantarflexion, and ankle moments were defined as positive for plantarflexion and negative for

dorsiflexion; Knee angles were defined as positive for flexion and negative for extension, and knee

moments were defined as positive for extension and negative for flexion; Hip angles were defined as

positive for flexion and negative for extension, and hip moments were defined as positive for extension

and negative for flexion. In all cases, zero joint angle was defined as the angle during quiet standing

with the Prescribed prosthesis. In all cases, joint power was unchanged in the conversion to gait analysis

conventions, with positive remaining positive.

S2 Supplementary Results

S2.1. Supplementary Data

Please find a file archive named Quesada_2016_SuppData.zip included as supplementary material

online. This archive includes a Matlab data structure with mean data for all conditions, subjects and

outcomes measured, including ground reaction forces, center-of-mass power, joint mechanics, prosthesis

mechanics, electromyography, metabolic rate and preference. Included is a ReadMe file explaining the

organization of the data structure. Researchers are encouraged to contact the corresponding author with

any questions about how to access this data.

S2.2. Supplementary Figures

The enclosed supplementary figures present prosthesis ankle power measured using onboard sensors

(Fig. S2), the torque-angle relationship for the prosthesis (Fig. S3), prosthesis-side knee power and

work-rates during swing (Fig. S4), ground reaction forces (Fig. S5), flexion-extension mechanics for the

intact-side joints (Fig. S6) and prosthesis-side joints (Fig. S7), three-dimensional joint and pelvis angles

(Fig. S8), electromyography for the intact-side muscles (Fig. S9) and prosthesis-side muscles (Fig. S10),

center-of-mass work rates for individual subjects (Fig. S11) and metabolic rate versus net prosthesis

work rate for one subject on 10 separate data collection days (Fig. S12).

Page 5: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

On

bo

ard

Pro

sth

esis

An

kle

Po

we

r (W

. kg

-1)

Stride (%)

Med-High

Med

Med-Low

Highest

High

Low

Negative

-1

0

1

2

3

4

5

0 10 20 30 40 50 60 70 80 90 100

Figure S2: Prosthetic ankle joint power calculated based on onboard measurements of joint velocity and torque. Peakankle power ranged from about half the value for Prescribed to about three times Prescribed. Patterns were similar toinverse-dynamics based power (cf. Fig. 2), but with less negative work during early and mid-stance, and without theburst of negative work just before push-off. Differences may relate to motion capture affect, filtering of motion capturedata, or compliance in the prosthesis forefoot. This pattern of onboard joint power is similar to the patterns observedfor other prostheses with active ankle push-off, such as the device reported by Au (2007; cf. Fig. 5-13), which tendto have less negative work in early and mid-stance and more rapid changes in power at the onset of push-off thanmeasured for the same devices using inverse dynamics (Esposito et al., 2015). We provide both measurements tofacilitate comparisons.

0

0.6

0.8

1.2

0.4

0.2

-0.2

1

1.4

Pro

sth

esis

An

kle

Jo

int To

rqu

e (

N. m

. kg

-1)

Prescribed

Med-High

Med

Med-Low

Highest

High

Low

Negative

Ankle Angle (rad)

0-0.1-0.2 0.1 0-0.1 0.40.1 0.2 0.3

Figure S3: Prosthetic ankle joint torque versus joint angle measured using inverse dynamics (Prescribed, left) oronboard sensors (emulated, right). Progression in time is indicated by arrows. During walking with the Prescribed foot,a counterclockwise work loop was generated, indicating net absorption of energy by the prosthesis. During emulatorconditions, work loops ranged from thin counterclockwise (Negative) to wide clockwise (Highest), indicating a largerange of net energy absorption or production by the prosthesis. These work loops are similar to those reported for prioractive prostheses (Herr & Grabowski, 2012), with the difference that the present results have a more circular, ratherthan dog leg shape, with a sharper corner at the top.

Page 6: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

0

0.4

-0.4

-0.8

-1.2

0.8

Pro

sth

esis

-Sid

e K

ne

e P

ow

er

(W. k

g-1

)

0 10 20 30 40 50 60 70 80 90 100

Stride (%)

a b

Prescribed

Pro

sth

esis

-Sid

e K

ne

e W

ork

Ra

te (

J. k

g-1

. s-1

)

0

ANOVA p = 2.10-4 ANOVA p = 1.0

a b

-0.02

-0.04

-0.06

ANOVA p = 9.10-4

+ =

Med-HighMedMed-Low

HighestHigh

LowNegative

c

Figure S4: The pattern of prosthesis-side knee power (top) during swing was altered with increasing net prosthesis workrate. Mid-swing became more negative (a) while late swing became less negative (b). However, the total absorptionduring swing (c) was unchanged.

Page 7: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

-2

0

2

4

6

8

10

12

Gro

un

d R

ea

ctio

n F

orc

es (

N. k

g-1

)

Stride (%)

0 10 20 30 40 50 60 70 80 90 100

fore-aft

vertical

Prescribed

Med-High

Med

Med-Low

Highest

High

Low

Negative

Figure S5: Vertical and fore-aft components of ground reaction force were strongly affected by prosthesis push-offwork. As net prosthesis work rate increased, the peak vertical component of force during double-support decreased forboth the prosthesis-side and intact-side limbs. The peak forward component of force on the prosthesis side increased,while the peak aftward force on the intact limb was unchanged. Vertical and fore-aft forces on the prosthesis sidepersisted longer, while peak vertical force in the intact limb occurred later. These trends are consistent with (and in factcompletely determine) observed patterns in center-of-mass power (cf. Fig. 5).

Page 8: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Intact-Side Hip Intact-Side Ankle

An

gle

(d

eg

)To

rqu

e (

N. m

. kg

-1)

Po

we

r (W

. kg

-1)

Stride (%)

0 50 100

Stride (%)

0 50 100

Stride (%)

0 50 100

2

-20

0

20

0.5

-0.5

1.5

0

1

40

60

0

-2

Intact-Side Knee

Med-Low Med Med-High High HighestPrescribed Negative Low

fle

xio

ne

xte

nsio

n

fle

xio

ne

xte

nsio

n

pla

nta

rfle

xio

nd

ors

ifle

xio

n

fle

xio

ne

xte

nsio

n

fle

xio

ne

xte

nsio

n

pla

nta

rfle

xio

nd

ors

ifle

xio

n

Figure S6: Intact-side flexion-extension joint mechanics, provided for reference. There were no apparent trends inintact-side joint mechanics. Zero joint angle corresponds to quiet standing with the Prescribed prosthesis. Trajectoriesbegin with intact-side heel strike at 0% stride.

Page 9: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

0 50 100 0 50 100 0 50 100

2

0

0

-20

20

40

60

0

0.5

1

1.5

-0.5

-2

Prosthesis-Side Hip Prosthesis-Side Knee Prosthesis-Side Ankle

An

gle

(d

eg

)To

rqu

e (

N. m

. kg

-1)

Po

we

r (W

. kg

-1)

Stride (%) Stride (%) Stride (%)

fle

xio

ne

xte

nsio

n

fle

xio

ne

xte

nsio

n

pla

nta

rfle

xio

nd

ors

ifle

xio

n

fle

xio

ne

xte

nsio

n

fle

xio

ne

xte

nsio

n

pla

nta

rfle

xio

nd

ors

ifle

xio

n

Med-Low Med Med-High High HighestPrescribed Negative Low

Figure S7: Prosthesis-side flexion-extension joint mechanics, provided for reference. Aside from prosthesis-side hippower (cf. Fig. 6), knee power (Fig. S4) and ankle power (cf. Fig. 2), there were no other apparent changes inprosthesis-side mechanics. Zero joint angle corresponds to quiet standing with the Prescribed prosthesis. Trajectoriesbegin with prosthesis-side heel strike at 0% stride.

Page 10: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

[ze

ro b

y d

efin

itio

n]

vargusvargus

abductionadduction

20

10 0

-10

-20

Str

ide

(%

)S

trid

e (

%)

Str

ide

(%

)

[ze

ro b

y d

efin

itio

n]

externalinternal

externalinternal

05

01

00

05

01

00

05

01

00

20

10 0

-10

-20

Pro

sth

esis

-Sid

e H

ipP

rosth

esis

-Sid

e K

ne

eP

rosth

esis

-Sid

e A

nkle

extensionflexion

extensionflexion

plantarflexiondorsiflexion

50 0

-50

[ze

ro b

y d

efin

itio

n]

abductionadduction

vargusvargus

20

10 0

-10

-20

20

10 0

-10

-20

Str

ide

(%

)S

trid

e (

%)

Str

ide

(%

)

[ze

ro b

y d

efin

itio

n]

externalinternal

externalinternal

05

01

00

05

01

00

05

01

00

Inta

ct-

Sid

e H

ipIn

tact-

Sid

e K

ne

eIn

tact-

Sid

e A

nkle

extensionflexion

extensionflexion

plantarflexiondorsiflexion

50 0

-50

FRONTAL

Angle (deg)

pros lat intact lat

20

10 0

-10

-20

20

10 0

-10

-20

Str

ide

(%

)

TRANSVERSE

Angle (deg)

05

01

00

pros forw intact forw

SAGITTAL

Angle (deg)

Pe

lvis

05 -510

15

anterior posterior

Figu

reS

8:Th

ree-

dim

ensi

onal

join

tan

dpe

lvis

segm

ent

angl

es,

prov

ided

for

refe

renc

e.P

atte

rns

ofm

otio

nfa

llw

ithin

rang

esty

pica

lof

clin

ical

gait

anal

ysis

for

ampu

tees

.Pe

lvis

traje

ctor

ies

begi

nw

ithpr

osth

esis

-sid

ehe

elst

rike

at0%

strid

e,w

ithpo

sitiv

ean

dne

gativ

ean

gles

defin

edw

ithre

spec

tto

pros

thes

is(p

ros)

posi

tion.

Join

ttra

ject

orie

sbe

gin

with

ipsi

late

ralh

eels

trik

eat

0%st

ride,

i.e.

inta

ct-s

ide

for

inta

ctjo

intd

ata

and

pros

thes

is-s

ide

for

pros

thes

is-s

ide

join

tdat

a.H

ipad

duct

ion

durin

gsw

ing

acro

ssal

lcon

ditio

nsm

aybe

the

resu

ltof

rela

tivel

yw

ide

step

sta

ken

onth

esp

lit-b

eltt

read

mill

.Ank

lero

tatio

nsou

tsid

eof

plan

tarfl

exio

n-do

rsifl

exio

nw

ere

not

capt

ured

usin

gth

elo

calr

efer

ence

fram

esde

fined

abov

e,be

caus

eou

rpr

imar

yin

tere

stw

aspl

anta

rflex

ion-

dors

iflex

ion

ofpr

osth

etic

stru

ctur

esw

ithlit

tlefro

ntal

and

coro

nalc

ompl

ianc

e.

Page 11: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Medial Soleus

Inta

ct-

Sid

e N

orm

aliz

ed

EM

G A

ctivity

Stride (%) Stride (%)

Lateral Soleus

0 50 100 0 50 100

2

1

0

Medial Gastrocnemius Lateral Gastrocnemius

2

1

0

Vastus Medialis Tibialis Anterior

2

1

0

Rectus Femoris Biceps Femoris

2

1

0

Med-Low Med Med-High High HighestPrescribed Negative Low

Figure S9: Intact-side electromyography, provided for reference. Aside from biceps femoris activity (cf. Fig. 8), trendswere not observed for any muscles. Notably, while activity in the lateral soleus and vastus medialis were higher insome conditions than with the prescribed prosthesis, there was no clear effect of prosthesis work level. Such changestherefore do not seem to provide an explanation for the lack of reduction in metabolic rate with higher levels of prosthesiswork. Trajectories begin with intact-side heel strike at 0% stride.

Page 12: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Stride (%)

Stride (%)Vastus Medialis

0 50 100

2

1

0

Rectus Femoris Biceps Femoris

0 50 100

2

1

0

Pro

sth

esis

-Sid

e N

orm

aliz

ed

EM

G A

ctivity

Med-Low Med Med-High High HighestPrescribed Negative Low

Figure S10: Prosthesis-side electromyography, provided for reference. Aside from biceps femoris (cf. Fig. 7), trendswere not observed for any muscles. Trajectories begin with prosthesis-side heel strike at 0% stride.

Page 13: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Subject 1

Subject 2

Subject 3

Subject 4

Subject 5

Subject 6

-4

4

0

-4

4

0

-4

4

0

0 20 40 60 80 100 0 20 40 60 80 100

Ce

nte

r o

f M

ass

Po

we

r (W

. kg

-1)

Ce

nte

r o

f M

ass

Po

we

r (W

. kg

-1)

Ce

nte

r o

f M

ass

Po

we

r (W

. kg

-1)

intact sideprosthesis side

Stride (%) Stride (%)

Med-Low Med Med-High High HighestPrescribed Negative Low

Figure S11: Center-of-mass power trajectories varied greatly between subjects. This variability makes it difficult toextend conclusions made during experiments on non-amputee populations, which are generally more uniform, to am-putees. Red lines are intact-side trajectories, blue lines are prosthesis-side trajectories.

Page 14: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

Day 1

Day 2

Day 5

Day 6

Day 9

Day 10

Average

-5 0 5 10 15 20 25 30 35

Net Prosthesis Emulator Work (J)

200

220

240

260

280

300

320

Ne

t M

eta

bo

lic R

ate

(W

)

Figure S12: Metabolics data from six of ten data collections conducted with Subject 1. Over the course of all experi-ments, there appeared to be no relationship between metabolic rate and net prosthesis work rate. Data were collectedat different times of the day, which may account for some of the variance in average metabolic rate per day. Mean dataper condition are in black. Whiskers denote standard error in metabolic rate (vertical) and prosthesis work (horizontal).

Page 15: Supplementary Materials Increasing ankle push-off work ...biomechatronics.cit.cmu.edu/publications/Quesada_2016_JB---SuppMat.pdf · Supplementary Materials Increasing ankle push-off

References

Au, S. K., 2007. Powered Ankle-Foot Prosthesis for the Improvement of Amputee Walking Economy.

Doctoral Dissertation, Massachusetts Institute of Technology.

Caputo, J. M. and Collins, S. H., 2014a. A universal ankle-foot prosthesis emulator for experiments

during human locomotion. ASME Journal of Biomechanical Engineering 136, 035002.

Caputo, J. M. and Collins, S. H., 2014b. Prosthetic ankle push-off work reduces metabolic rate but not

collision work in non-amputee walking. Nature Scientific Reports 4, 7213.

de Lava, P., 1996. Adjustments to Zatsiorsky-Seluyanov’s segment inertia parameters. Journal of

Biomechanics 29, 1223–1230.

Esposito, E. R., Whitehead, J. M. A., and Wiken, J. M., 2015. Step-to-step transition work during level

and inclined walking using passive and powered ankle-foot prostheses. Prosthetics and Orthotics

International, 0309364614564021.

Hawes, M. R., and Sovak, D., 1994. Quantitative morphology of the human foot in a North American

population, Ergonomics, 37(7), 1213–1226.

Herr, H. M. and Grabowski, A. M., 2012. Bionic ankle-foot prosthesis normalizes walking gait for

persons with leg amputation. Proceedings of the Royal Society of London B: Biological Sciences 279,

457–464.

Winter, D. A., 1991. The Biomechanics and Motor Control of Human Gait: Normal, Elderly and

Pathological. Waterloo Biomechanics, Waterloo.

Zhang, J., Cheah, C. C., and Collins, S. H., 2015. Experimental comparison of torque control methods

on an ankle exoskeleton during human walking. Proceedings of the IEEE International Conference on

Robotics and Automation (ICRA), pages 5584-5589.