SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine &...
Transcript of SuperLine & Implantium - American Dental · PDF fileSuperLine Characteristics SuperLine &...
SuperLine & ImplantiumProduct Catalog
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 2
®™SuperLine & Implantium
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 3
IntroductionS.L.A. Surface 04SuperLine Characteristics 06SuperLine Color Coding by Diameter 08SuperLine Fixture 09IMPLANTIUM Characteristics 12IMPLANTIUM Color Coding by Diameter 14IMPLANTIUM Fixture 15
Surgical ComponentsCover Screw 16Healing Abutment 17
Prosthetic Procedure 1Dual / Combi Abutment - Abutment Level Impression 18Combi Abutment 19Dual Abutment [Hex] 20Dual Abutment [Non-hex] 21Abutment Level Impression Components 22Restorative Kit 23
Prosthetic Procedure 2Dual / Dual Milling / Angled / Direct-Casting / Metal-Casting / Temporary (Plastic & Ti) Abutment - Fixture Level Impression 24Fixture Level Impression Components 25Dual Milling Abutment [Ti-G4] 27Dual Milling Abutment [Ti-G2] 29Angled Abutment [Ti-G4 / 15°] 31Angled Abutment [Ti-G4 / 25°] 32Angled Abutment [Ti-G2 / 15°] 33Angled Abutment [Ti-G2 / 25°] 34
Direct-Casting Abutment 35Metal-Casting Abutment 35Temporary Abutment 36
Prosthetic Procedure 3Screw Abutment - Abutment Level Impression 37Screw Abutment 38Screw Abutment Impression Components 39
Prosthetic Procedure 4Overdenture Procedure - Positioner / Ball / Magnetic Attachment 42Ball Attachment 43
Instruments Surgical Kit (Full) 44Drill Stopper Kit 45Drill 46Stopper 49Instrument 50DASK 53Sinus Bur Kit / Sinus Kit 54DASK / Sinus Bur Kit / Sinus Kit 55Osteotome Kit 56Trephine Kit 57Prosthetic Kit 58Planning Kit 59Prosthetic and Laboratory Instrument 60Help Kit 62Surgical Maintenance 63DASK Maintenance 64
Contents
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 4
SuperLine & Implantium Product Catalog
S.L.A. Surface04
S.L.A. (Sandblasting with Large grit and Acid etching)
Reference: Kim H., et. al. “The Biocompatibility of S.L.A.-treated titanium implants.”
Biomed. Mater. 2008; 3(2): 025011.
Human Osteoblast
Figure 2. SEM topography of S.L.A. surface.
1250X
3000X
In vivo test
Implant (S.L.A.)
100x 40x
Figure 1. Histological image of new bone apposition over the implant surface at four weeks.
Bone
(A)
(B)
Bone Bone
Implant (S.L.A.)
(A) (B)
3000X
Figure 3. SEM image of human osteoblasts on S.L.A. surfaceafter 7 days of cell culture.
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 5
™
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 6
SuperLine Characteristics
"Immediate Implantation with Excellent Bone Response"
• Higher stabilization in extraction socket• Early loading in upper posterior• Harmony with anatomy• Sharp & fast insertion
PlatformØ
BodyØ
AbutmentG/H
Fixt
ure
Leng
th
Bevel
AbutmentØ
Abu
tmen
t Hei
ght
Selection GuidelineIdeal emergence profile for each tooth
Platform
Platform
SuperLine & Implantium Product Catalog06
A
D
B
C
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 7
SuperLine Characteristics
SuperLine & Implantium Product Catalog 07
B
• The conical hex connection between implant andabutment interface ensures hermetic sealing.
• The biologic connection distributes the load to thefixture evenly. Therefore it helps minimizemicro-movement and marginal bone loss.
• All implant diameters share the same internal hex.
Biological Connection
• Increased thread height helps increase the initial stability.
• Double thread may decrease the chair time of implantation
Double Thread & Thread Height
E Single Prosthetic Platform with
variety of prosthesis
• One abutment screw fits all abutments and fixture platforms.
• Single Abutment Connection is used for all implant diameters.
• One hex screw driver fits all abutment screws.• The greater distance betweenthe threads may promote earlyosseointegration
Osseointegration
Dual Milling Angled Direct Screw
A Tapered Design
• Tapered load distribution may achieve excellentbone response.
• Tapered design may harmonize with surroundingbone anatomically.
• The large surface area helps provide excellent initialstability with sinus augmentation.
C
D
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 8
SuperLine Color Coding by Diameter
Color Coding by Diameter
Cap Color
FixtureSuperLine
FixturePlatformDiameter
Unit: mm
Platform
• Cover screw is included.
FixtureBody
Diameter
Body
Yellow Green Blue Red Orange Violet
3.6 4.0 4.5 5.0 6.0 7.0
3.4 3.8 4.3 4.8 4.8 5.8
0.15 0.2 0.4 0.6 0.7 1.0FixtureBevelHeight
Bevel
SuperLine & Implantium Product Catalog08
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 9
SuperLine FixtureUnit: mm
Scale 1 : 1.5 / mm
3.6
L
3.4
4.0
L
3.8
08 10 12 144.5
L
4.3
5.0
L
4.8
L REF
8 FX 45 08 SWC
10 FX 45 10 SWC
12 FX 45 12 SWC
14 FX 45 14 SWC
L REF
8 FX 50 08 SWC
10 FX 50 10 SWC
12 FX 50 12 SWC
14 FX 50 14 SWC
08 10 12 14
08 10 12 14
08 10 12 14
L REF
8 FX 40 08 SWC
10 FX 40 10 SWC
12 FX 40 12 SWC
14 FX 40 14 SWC
Platform 3.6 | Body 3.4
L REF
8 FX 36 08 SWC
10 FX 36 10 SWC
12 FX 36 12 SWC
14 FX 36 14 SWC
0.6
0.4
0.2
0.15
• Cover screw is included.
Platform 4.0 | Body 3.8
Platform 4.5 | Body 4.3
Platform 5.0 | Body 4.8
Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.
SuperLine & Implantium Product Catalog 09
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 10
SuperLine FixtureUnit: mm
Scale 1 : 1.5 / mm
7.0
L
5.8
L
4.8
6.008 10 12
08 10 12
L REF
8 FX 60 08 SWC
10 FX 60 10 SWC
12 FX 60 12 SWC
L REF
8 FX 70 08 SWC
10 FX 70 10 SWC
12 FX 70 12 SWC
4.5
G/H 3.0H 5.0
HAB453050L and FX4510SWCCS38 and FX4510SWC
4.5
3.4
0.7
1.0
• Cover screw is included.
Platform 6.0 | Body 4.8
Platform 7.0 | Body 5.8
Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.
SuperLine & Implantium Product Catalog10
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 11
®
Product Catalog Final 2012_Layout 1 9/11/12 8:46 AM Page 12
3.6 3.6
3.6
4.5
4.5 4.5
4.54.0
4.0
4.0
4.0 4.0 4.0
4.0
Implantium Characteristics
C
D
Platform
BodyØ
Final DrillØ
Neck
Bevel
AbutmentG/H
Abu
tmen
t Hei
ght
Fixt
ure
Leng
th
3
MaximumReduction Line
Abutment
F
A
G
H
B
E
Selection GuidelineIdeal emergence profile for each tooth
Platform
Platform
SuperLine & Implantium Product Catalog12
Product Catalog Final 2012_Layout 1 9/11/12 9:17 AM Page 13
Abutment TiN-Coating
• Esthetic gold color with TiN-coating.
Flat End
• The flat end design reduces bone perforation risk.
Cutting Edge
• The 3 blade self tapping design minimizes bone destruction.
• Tapered apical shape promotes easier insertion.
Implantium Characteristics
F
HG
C Biological Connection
• The conical hex connection between implant and abutmentinterface ensures hermetic sealing.
• The biologic connection distributes the load to the fixtureevenly. Therefore it helps minimize micro-movement andmarginal bone loss.
• All implant diameters share the same internal hex.
Bacteria Resistant Bevel
• The tapered bevel platform design may make boneprofiling unnecessary at 1st, 2nd surgery.
Biological Thread
• Thread platform design creates excellent bone toimplant contact.
• Threads engage and penetrate bone with ease.
A Optimal Fixation Threads
• Synchronized positive neck threads.
• Initial stability & maximum sealing between the corticalbone and fixture.
• Optimal fixation threads reduce stress of marginalcortical bone and minimize marginal bone loss.
Regular Platform
E
B
D
Dual Milling Angled Direct Screw
Single Prosthetic Platform with
variety of prosthesis
• One abutment screw fits all abutments and fixture platforms.
• Single Abutment Connection is used for all implant diameters.
• One hex screw driver fits all abutment screws.
2.3
2.0
SuperLine & Implantium Product Catalog 13
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 14
Implantium Color Coding by Diameter
Color Coding by Diameter
Cap Color
FixtureImplantium
(Mount Free)
FixturePlatformDiameter
Platform
FixtureBody
Diameter
Body
Yellow Green Blue Red
3.6 4.0 4.5 5.0
3.4 3.8 4.3 4.8
FixtureBevelHeight
Bevel
0.15 0.2 0.4 0.6
Unit:mm• Cover screw is included.
SuperLine & Implantium Product Catalog14
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 15
Implantium FixtureUnit: mm
Scale 1 : 1.5 / mm
08 10 12 143.6
L
3.4
L REF
8 FX 34 08 MLC
10 FX 34 10 MLC
12 FX 34 12 MLC
14 FX 34 14 MLC
4.0
L
3.8
4.5
L
4.3
5.0
L
4.8
08 10 12 14 L REF
8 FX 38 08 MLC
10 FX 38 10 MLC
12 FX 38 12 MLC
14 FX 38 14 MLC
08 10 12 14 L REF
8 FX 43 08 MLC
10 FX 43 10 MLC
12 FX 43 12 MLC
14 FX 43 14 MLC
08 10 12 14 L REF
8 FX 48 08 MLC
10 FX 48 10 MLC
12 FX 48 12 MLC
14 FX 48 14 MLC
0.15
0.2
0.4
0.6
• Cover screw is included.
Note : To prevent damage to the implant driver or fixture, do not over torque during fixture insertion.
Platform 3.6 | Body 3.4
Platform 4.0 | Body 3.8
Platform 4.5 | Body 4.3
Platform 5.0 | Body 4.8
SuperLine & Implantium Product Catalog 15
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 16
Cover ScrewUnit: mm
Scale 1 : 1.5 / mm• Single use only.
Color : Blue / Platform 4.0, 4.5, 5.0, 5.5, 6.0, 7.0Body 3.8, 4.3, 4.8, 5.8
Type REF Smal l CS34
Type REF Regular CS38
CS38 and FX4510SWC
4.53.8
Note : Hex driver: Use no more than 5N cm torque when screwing a cover screw to a fixture. If hex is worn, slot on the head of the product can be used to rotate it.
Color : Black / Platform 3.6 / Body 3.4
SuperLine & Implantium Product Catalog16
CS34 and FX3610SWC
CS38 and FX4510SWC
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 17
Healing Abutment4.5
G/H 3.0H 5.0
HAB453050L and FX4510SWC
Diameter 4.0
G/H H REF
2.0 2.0 HAB 40 20 20 L
2.0 3.5 HAB 40 20 35 L
3.0 5.0 HAB 40 30 50 L
4.0 7.0 HAB 40 40 70 L
6.56.5
6.5
3.52.05.0
3.07.0
4.0
4.04.0
4.0
3.52.05.0
3.07.0
4.0
4.54.5
4.5
3.5 5.03.0
7.04.0
5.55.5
5.5
3.52.05.0
3.07.0
4.0
7.5
5.03.0
4.0
2.0
4.5
5.5
6.5
Diameter 4.5
G/H H REF
2.0 2.0 HAB 45 20 20 L
2.0 3.5 HAB 45 20 35 L
3.0 5.0 HAB 45 30 50 L
4.0 7.0 HAB 45 40 70 L
Diameter 5.5
G/H H REF
2.0 2.0 HAB 55 20 20 L
2.0 3.5 HAB 55 20 35 L
3.0 5.0 HAB 55 30 50 L
4.0 7.0 HAB 55 40 70 L
Diameter 6.5
G/H H REF
2.0 2.0 HAB 65 20 20 L
2.0 3.5 HAB 65 20 35 L
3.0 5.0 HAB 65 30 50 L
4.0 7.0 HAB 65 40 70 L
Diameter 7.5, 8.5, 9.5
G/H H REF
3.0 5.0 HAB 75 30 50 L
3.0 5.0 HAB 85 30 50 L
3.0 5.0 HAB 95 30 50 L
8.5
5.03.0
9.5
5.03.0
2.02.0
2.0
2.0
Unit: mm
Scale 1 : 1.5 / mm
Note : Hex driver: Use no more than 10N cm torque when screwing a Healing Abutment to a fixture. If hex is worn, slot on the head of the product can be used to rotate it.
• Single use only.
SuperLine & Implantium Product Catalog 17
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 18
Prosthetic Procedure 1
Combi / Dual Abutment
Closed Tray technique
Cemented restoration
Modification
Abutment Level Impression
Burn-out Cylinder
Dual AbutmentHex / Non-hex 4.5 / 5.5 / 6.5
Page 20, 21
Combi Abutment4.5 / 5.5 / 6.5
Page 19
Impression CopingTransfer (Snap on) 4.5 / 5.5 / 6.5
Page 22
AnalogLong 4.5 / 5.5 / 6.5Page 22
AnalogShort 4.5 / 5.5 / 6.5Page 22
BridgeRotational
4.5 / 5.5 / 6.5Page 22
SingleNon-Rotational
4.5 / 5.5 / 6.5Page 22
Impression Technique and Restoration Selection
SuperLine & Implantium Product Catalog18
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 19
Combi Abutment
1.0 1.5 2.5 3.5 4.5 5.5
1.5 2.5 3.5 4.5 5.5
G/H 3.5
5.5
5.5
1.5
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
G/H REF REF
1.0 CAB 45 10 L CAB 45 10 SL
1.5 CAB 45 15 L CAB 45 15 SL
2.5 CAB 45 25 L CAB 45 25 SL
3.5 CAB 45 35 L CAB 45 35 SL
4.5 CAB 45 45 L CAB 45 45 SL
5.5 CAB 45 55 L CAB 45 55 SL
Diameter 4.5
CAB5535L and FX4510SWC
G/H 3.54.0
5.5
CAB5535SL and FX4510SWC
Type
Long
Type
Short
G/H REF REF
1.5 CAB 55 15 L CAB 55 15 SL
2.5 CAB 55 25 L CAB 55 25 SL
3.5 CAB 55 35 L CAB 55 35 SL
4.5 CAB 55 45 L CAB 55 45 SL
5.5 CAB 55 55 L CAB 55 55 SL
Diameter 5.5
Type
Long
Type
Short
1.5 2.5 3.5 4.5 5.5
G/H REF REF
1.5 CAB 65 15 L CAB 65 15 SL
2.5 CAB 65 25 L CAB 65 25 SL
3.5 CAB 65 35 L CAB 65 35 SL
4.5 CAB 65 45 L CAB 65 45 SL
5.5 CAB 65 55 L CAB 65 55 SL
Diameter 6.5
Type
Long
Type
Short
G/H
G/H
G/H
5.5
4.0
G/H
G/H
5.5
4.0
G/H
G/H
5.5
4.0
G/H
G/H
Unit: mm
Scale 1 : 1.5 / mm
SuperLine & Implantium Product Catalog 19
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 20
Dual Abutment [Hex]
G/H 3.5
5.5
5.5
1.5
G/H REF
1.0 DAB 45 10 HL
1.5 DAB 45 15 HL
2.5 DAB 45 25 HL
3.5 DAB 45 35 HL
4.5 DAB 45 45 HL
5.5 DAB 45 55 HL
1.0 1.5 2.5 3.5 4.5 5.5
Diameter 4.5 I Hex
G/H REF
1.5 DAB 55 15 HL
2.5 DAB 55 25 HL
3.5 DAB 55 35 HL
4.5 DAB 55 45 HL
5.5 DAB 55 55 HL
1.5 2.5 3.5 4.5 5.5Diameter 5.5 I Hex
DAB5535HL and FX4510SWC
G/H REF
1.5 DAB 65 15 HL
2.5 DAB 65 25 HL
3.5 DAB 65 35 HL
4.5 DAB 65 45 HL
5.5 DAB 65 55 HL
1.5 2.5 3.5 4.5 5.5Diameter 6.5 I Hex
G/H
G/H
G/H
G/H
5.5
G/H
5.5
G/H
5.5
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
SuperLine & Implantium Product Catalog20
2.3
2.0
2.3
2.0
2.3
2.0
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 21
Dual Abutment [Non-Hex]
G/H 3.5
5.5
5.5
1.5
G/H REF
1.0 DAB 45 10 NL
1.5 DAB 45 15 NL
2.5 DAB 45 25 NL
3.5 DAB 45 35 NL
4.5 DAB 45 45 NL
5.5 DAB 45 55 NL
1.0 1.5 2.5 3.5 4.5 5.5
Diameter 4.5 I Non-hex
G/H REF
1.5 DAB 55 15 NL
2.5 DAB 55 25 NL
3.5 DAB 55 35 NL
4.5 DAB 55 45 NL
5.5 DAB 55 55 NL
1.5 2.5 3.5 4.5 5.5
Diameter 5.5 I Non-hex
DAB5535NL and FX4510SWC
G/H REF
1.5 DAB 65 15 NL
2.5 DAB 65 25 NL
3.5 DAB 65 35 NL
4.5 DAB 65 45 NL
5.5 DAB 65 55 NL
1.5 2.5 3.5 4.5 5.5Diameter 6.5 I Non-hex
G/H
G/H
G/H
G/H
5.5
G/H
5.5
G/H
5.5
2.3
2.0
2.3
2.0
2.3
2.0
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
SuperLine & Implantium Product Catalog 21
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 22
Abutment Level Impression Components
Diameter REF
4.5 CCC 45 L
5.5 CCC 55 L
6.5 CCC 65 L
4.5 5.5 6.5
Comfort Cap
4.5 5.5 6.5 Diameter REF
4.5 CIC 45 L
5.5 CIC 55 L
6.5 CIC 65 L
Impression Coping
Comfort Cap | Snap on
6.7
4.5 5.5 6.5
4.8
Type Diameter REF
4.5 CCC 45 CS
Short 5.5 CCC 55 CS
6.5 CCC 65 CS
4.5 CCC 45 C
Long 5.5 CCC 55 C
6.5 CCC 65 C
6.8
10.4
Lab Analog
Type Diameter REF
4.5 CAN 45 SL
Short 5.5 CAN 55 SL
6.5 CAN 65 SL
4.5 CAN 45 LL
Long 5.5 CAN 55 LL
6.5 CAN 65 LL
Burn-out Cylinder
Type Diameter REF
4.5 CBC 45 SL
Single 5.5 CBC 55 SL
6.5 CBC 65 SL
4.5 CBC 45 BL
Bridge 5.5 CBC 55 BL
6.5 CBC 65 BL
4.5 5.5 6.5
4.0
12.0
5.5
12.0
4.5 5.5 6.5
12.8
12.8
Abutment Screw ASC 2045
Unit: mm
Scale 1 : 1 / mm
10.2
SuperLine & Implantium Product Catalog22
2.3
2.0
REF
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 23
Lab. Components
Comfort Cap Impression Coping Analog Burn-out Cylinder
XSDAB 45 S CCC 45 CS CIC 45 L
CAN 45 SL CBC 45 SL CBC 45 BL
XSDAB 45 CCC 45 C CAN 45 LL
XSDAB 55 S CCC 55 CS CIC 55 L
CAN 55 SL CBC 55 SL CBC 55 BL
XSDAB 55 CCC 55 C CAN 55 LL
XSDAB 65 S CCC 65 CS CIC 65 L
CBC 65 SL CBC 65 SL CBC 65 BL
XSDAB 65 CCC 65 C CAN 65 LL
Combi & Dual Abutment
REF
Restorative Kit
SuperLine & Implantium Product Catalog 23
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 24
Impression Technique and Restoration Selection
Dual / Milling / Angled / Direct and Metal Casting / Temporary (Plastic & Ti) Abutment
Fixture Level Impression
Hex Non-hex
Impression Coping / Pick-upOpen Tray technique (Complicated case)
4.0 / 4.5 / 5.5 / 6.5Page 25
Impression Coping / TransferClosed Tray technique (Simple case)
4.0 / 4.5 / 5.5 / 6.5Page 26
Hex Non-hex
AnalogDAN 34 / DAN 38
Page 25,26
Cemented Restoration Screw-Retained Restoration
Modification Modification
DualAbutment
Hex / Non-hex4.5 / 5.5 / 6.5
Page 20, 21
Dual MillingAbutment
Hex / Non-hex4.0 / 4.5
5.5 / 6.5 / 7.5Page 27,28, 29,30
Direct-CastingAbutment
Hex / Non-hex4.5
Page 35
Metal-CastingAbutment
Hex / Non-hex4.5
Page 35
TemporaryAbutment
Hex / Non-hex4.5 / 5.5 / 6.5
Page 36
AngledAbutment
Hex / Non-hex15° / 25°4.5 / 5.5
Page 31, 32, 33, 34
Prosthetic Procedure 2
SuperLine & Implantium Product Catalog24
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 25
12.0
4.0
12.0
4.5
Size REF
Short DPS 11
Long DPS 15
Impression Coping Pick-up Screw
Long
Short
Size Type REF
Short Hex DPU 40 11 HL
Short Non-hex DPU 40 11 NL
Long Hex DPU 40 15 HL
Long Non-hex DPU 40 15 NL
4.0 4.0 4.0 4.0
Impression Coping Pick-up 4.5
Size Type REF
Short Hex DPU 45 11 HL
Short Non-hex DPU 45 11 NL
Long Hex DPU 45 15 HL
Long Non-hex DPU 45 15 NL
Impression Coping Pick-up 5.5
Size Type REF
Short Hex DPU 55 11 HL
Short Non-hex DPU 55 11 NL
Long Hex DPU 55 15 HL
Long Non-hex DPU 55 15 NL
Impression Coping Pick-up 6.5
Size Type REF
Short Hex DPU 65 11 HL
Short Non-hex DPU 65 11 NL
Long Hex DPU 65 15 HL
Long Non-hex DPU 65 15 NL
Hex Non-hex
17.0 17.0
4.5 4.5
Hex Non-hex
17.0 17.0
5.5 5.5
Hex Non-hex
23.0
27.0
Fixture Platform Diameter REF 3.6 DAN 34
4.0, 4.5, 5.0, 6.0, 7.0 DAN 38
Analog
DAN 34 DAN 38
Fixture Level Impression Components
Note : 1)DAN34 should only be used with small diameter fixtures (Platform: 3.6mm/ Body: 3.4mm). 2)DAN38 should be used with all other fixture diameters.
Unit: mm
Scale 1 : 1.5 / mm
21.0 21.0 21.0 21.0
17.0 17.0 21.0 21.0
5.5 5.5
Hex Non-hex
Hex Non-hexHex Non-hex
6.5 6.5
Hex Non-hex
17.0 17.0
6.5
Hex
21.0
6.5
Non-hex
21.0
• Impression coping screw is included with impression coping.
4.5 4.5
Impression Coping Pick-up 4.0
SuperLine & Implantium Product Catalog 25
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 26
Fixture Level Impression Components
12.0
4.0
12.0
4.5
Size REF
Short DTS 11
Long DTS 15
Impression Coping Transfer Screw
Impression Coping Transfer 4.0
Size Type REF
Short Hex DTF 40 11 HL
Short Non-hex DTF 40 11 NL
Long Hex DTF 40 15 HL
Long Non-hex DTF 40 15 NL
Impression Coping Transfer 4.5
Size Type REF
Short Hex DTF 45 11 HL
Short Non-hex DTF 45 11 NL
Long Hex DTF 45 15 HL
Long Non-hex DTF 45 15 NL
Impression Coping Transfer 5.5
Size Type REF
Short Hex DTF 55 11 HL
Short Non-hex DTF 55 11 NL
Long Hex DTF 55 15 HL
Long Non-hex DTF 55 15 NL
Impression Coping Transfer 6.5
Size Type REF
Short Hex DTF 65 11 HL
Short Non-hex DTF 65 11 NL
Long Hex DTF 65 15 HL
Long Non-hex DTF 65 15 NL
4.0 4.0 4.0 4.0
Hex Non-hex Hex Non-hex
11.0 11.0
15.0 15.0
4.5 4.5 4.5 4.5
Hex Non-hex Hex Non-hex
11.0 11.0
15.0 15.0
5.5 5.5 5.5 5.5
Hex Non-hex Hex Non-hex
11.0 11.0
15.0 15.0
6.5 6.5 6.5 6.5
Hex Non-hex Hex Non-hex
11.0 11.0
15.0 15.0
Long
Short
14.0
18.0
Fixture Platform Diameter REF
3.6 DAN 34
4.0, 4.5, 5.0, 6.0, 7.0 DAN 38
Analog
DAN 34 DAN 38
Unit: mm
Scale 1 : 1.5 / mm• Impression coping screw is included with impression coping.
Note : 1)DAN34 should only be used with small diameter fixtures (Platform: 3.6mm/ Body: 3.4mm). 2)DAN38 should be used with all other fixture diameters.
SuperLine & Implantium Product Catalog26
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 27
G/H 1.5
12
DAB55157H/NL and FX4510SW
Diameter 4.0
Diameter 4.5
Diameter 5.5
G/H Type REF
1.0 Hex DAB 40 105 HL
1.0 Non-hex DAB 40 105 NL
G/H Type REF
1.5 Hex DAB 45 156 HL
1.5 Non-hex DAB 45 156 NL
G/H Type REF
1.5 Hex DAB 55 157 HL
1.5 Non-hex DAB 55 157 NL
2.5 Hex DAB 55 257 HL
2.5 Non-hex DAB 55 257 NL
4.0
1.0 1.0
Hex
5.5
4.0
Non-hex
4.5
1.5
1.5 1.5 2.5 2.5
1.5
Hex
4.5
Non-hex
5.5
Hex
5.5
Non-hex
5.5
Hex
5.5
Non-hex
Dual Milling Abutment [ Ti-G4]Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters.2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 27
2.3
2.0
2.3
2.0
2.3
2.0
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 28
Dual Milling Abutment [ Ti-G4]
Diameter 6.5 G/H Type REF
1.5 Hex DAB 65 158 HL
1.5 Non-hex DAB 65 158 NL
2.5 Hex DAB 65 258 HL
2.5 Non-hex DAB 65 258 NL
3.5 Hex DAB 65 358 HL
3.5 Non-hex DAB 65 358 NL
6.5
Hex
6.5
Non-hex
6.5
Hex
6.5
Non-hex
6.5
Hex
6.5
Non-hex
1.5 1.5 2.5 2.5
3.5 3.5
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog28
2.3
2.0
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 29
Dual Milling Abutment [ Ti-G2]
Diameter 4.0
Diameter 4.5
Diameter 5.5
G/H Type REF
1.0 Hex DAB 40 105 HG
1.0 Non-hex DAB 40 105 NG
G/H Type REF
1.5 Hex DAB 45 156 HG
1.5 Non-hex DAB 45 156 NG
G/H Type REF
1.5 Hex DAB 55 157 HG
1.5 Non-hex DAB 55 157 NG
2.5 Hex DAB 55 257 HG
2.5 Non-hex DAB 55 257 NG
4.0
1.0 1.0
Hex
4.0
Non-hex
4.5
1.5 1.5
Hex
4.5
Non-hex
1.5 1.5 2.5 2.5
5.5
Hex
5.5
Non-hex
5.5
Hex
5.5
Non-hex
G/H 1.5
12
DAB55157H/NG and FX4510SWC
5.5
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 29
2.3
2.0
2.3
2.0
2.3
2.0
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 30
2.3
2.0
Dual Milling Abutment [Ti-G2]
Diameter 6.5
G/H Type REF
1.5 Hex DAB 65 158 HG
1.5 Non-hex DAB 65 158 NG
2.5 Hex DAB 65 258 HG
2.5 Non-hex DAB 65 258 NG
3.5 Hex DAB 65 358 HG
3.5 Non-hex DAB 65 358 NG
Diameter 7.5
G/H Type REF
2.5 Hex DAB 75 259 HG
2.5 Non-hex DAB 75 259 NG
3.5 Hex DAB 75 359 HG
3.5 Non-hex DAB 75 359 NG
6.5
Hex
6.5
Non-hex
6.5
Hex
6.5
Non-hex
6.5
Hex
6.5
Non-hex
1.5 1.5 2.5 2.5
3.5 3.5
7.5
Hex
7.5
Non-hex
7.5
Hex
7.5
Non-hex
2.5 2.5 3.5 3.5
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than otherfixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog30
2.3
2.0
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 31
2.3
2.0
2.3
2.0
Non-hex
2.5
5.5
4.5
Angled Abutment [Ti-G4 / 15°]
G/H 1.5
10.5
15°
Hex
Diameter 4.5 | Angled 15°
AAB154515H/NL and FX4510SWC
Diameter 5.5 | Angled 15°
1.5
4.5
Non-hex
1.5
4.5
Hex
2.5
4.5
Non-hex
2.5
4.5
Hex
3.5
4.5
Non-hex
3.5
4.5
Hex
1.5
5.5
Non-hex
1.5
5.5
Hex
2.5
5.5
Hex
3.5
5.5
Non-hex
3.5
5.5
G/H Type REF
1.5 Hex AAB 15 45 15 HL
1.5 Non-hex AAB 15 45 15 NL
2.5 Hex AAB 15 45 25 HL
2.5 Non-hex AAB 15 45 25 NL
3.5 Hex AAB 15 45 35 HL
3.5 Non-hex AAB 15 45 35 NL
G/H Type REF
1.5 Hex AAB 15 55 15 HL
1.5 Non-hex AAB 15 55 15 NL
2.5 Hex AAB 15 55 25 HL
2.5 Non-hex AAB 15 55 25 NL
3.5 Hex AAB 15 55 35 HL
3.5 Non-hex AAB 15 55 35 NL
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 31
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 32
2.3
2.0
2.3
2.0
Non-hex
2.5
5.5
4.5
Angled Abutment [Ti-G4 / 25°]
G/H 1.5
10.5
25°
Hex
Diameter 4.5 | Angled 25°
AAB254515H/NL and FX4510SWC
Diameter 5.5 | Angled 25°
1.5
4.5
Non-hex
1.5
4.5
Hex
2.5
4.5
Non-hex
2.5
4.5
Hex
3.5
4.5
Non-hex
3.5
4.5
Hex
1.5
5.5
Non-hex
1.5
5.5
Hex
2.5
5.5
Hex
3.5
5.5
Non-hex
3.5
5.5
G/H Type REF
1.5 Hex AAB 25 45 15 HL
1.5 Non-hex AAB 25 45 15 NL
2.5 Hex AAB 25 45 25 HL
2.5 Non-hex AAB 25 45 25 NL
3.5 Hex AAB 25 45 35 HL
3.5 Non-hex AAB 25 45 35 NL
G/H Type REF.
1.5 Hex AAB 25 55 15 HL
1.5 Non-hex AAB 25 55 15 NL
2.5 Hex AAB 25 55 25 HL
2.5 Non-hex AAB 25 55 25 NL
3.5 Hex AAB 25 55 35 HL
3.5 Non-hex AAB 25 55 35 NL
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog32
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 33
2.3
2.0
2.3
2.0
Non-hex
2.5
5.5
4.5
Angled Abutment [Ti-G2 / 15°]
G/H 1.5
10.5
15°
Hex
Diameter 4.5 | Angled 15°
AAB154515H/NG and FX4510SWC
Diameter 5.5 | Angled 15°
1.5
4.5
Non-hex
1.5
4.5
Hex
2.5
4.5
Non-hex
2.5
4.5
Hex
3.5
4.5
Non-hex
3.5
4.5
Hex
1.5
5.5
Non-hex
1.5
5.5
Hex
2.5
5.5
Hex
3.5
5.5
Non-hex
3.5
5.5
G/H Type REF
1.5 Hex AAB 15 45 15 HG
1.5 Non-hex AAB 15 45 15 NG
2.5 Hex AAB 15 45 25 HG
2.5 Non-hex AAB 15 45 25 NG
3.5 Hex AAB 15 45 35 HG
3.5 Non-hex AAB 15 45 35 NG
G/H Type REF
1.5 Hex AAB 15 55 15 HG
1.5 Non-hex AAB 15 55 15 NG
2.5 Hex AAB 15 55 25 HG
2.5 Non-hex AAB 15 55 25 NG
3.5 Hex AAB 15 55 35 HG
3.5 Non-hex AAB 15 55 35 NG
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 33
Product Catalog Final 2012_Layout 1 9/11/12 8:47 AM Page 34
2.3
2.0
2.3
2.0Non-hex
3.5
4.5
Non-hex
2.5
5.5
4.5
Angled Abutment [Ti-G2 / 25°]
G/H 1.5
10.5
25°
Hex
Diameter 4.5 | Angled 25°
AAB254515H/NG and FX4510SWC
Diameter 5.5 | Angled 25°
1.5
4.5
Non-hex
1.5
4.5
Hex
2.5
4.5
Non-hex
2.5
4.5
Hex
3.5
4.5
Hex
1.5
5.5
Non-hex
1.5
5.5
Hex
2.5
5.5
Hex
3.5
5.5
Non-hex
3.5
5.5
G/H Type REF
1.5 Hex AAB 25 45 15 HG
1.5 Non-hex AAB 25 45 15 NG
2.5 Hex AAB 25 45 25 HG
2.5 Non-hex AAB 25 45 25 NG
3.5 Hex AAB 25 45 35 HG
3.5 Non-hex AAB 25 45 35 NG
G/H Type REF
1.5 Hex AAB 25 55 15 HG
1.5 Non-hex AAB 25 55 15 NG
2.5 Hex AAB 25 55 25 HG
2.5 Non-hex AAB 25 55 25 NG
3.5 Hex AAB 25 55 35 HG
3.5 Non-hex AAB 25 55 35 NG
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog34
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 35
2.3
2.0
2.3
2.0
4.5
Direct-Casting Abutment / Metal-Casting Abutment
G/H 1.0
12
4.5
Direct-Casting Abutment I Gold
RAB45GH/N and FX4510SWC
Hex
G/H Type REF
1.0 Hex RAB 45 GH
1.0 Non-hex RAB 45 GN
4.5
4.5
12
1.0
Metal-Casting Abutment I Co-Cr
G/H Type REF
1.0 Hex RAB 45 CH
1.0 Non-hex RAB 45 CN
4.5G/H 1.0
12
4.5
RAB45CH/N and FX4510SWC
Non-hex
4.5
4.5
12
1.0
Hex
4.5
4.5
12
1.0
Non-hex
4.5
4.5
12
1.0
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 35
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 36
2.3
2.0
2.3
2.0
Temporary Abutment
Plastic Temporary Abutment
Diameter G/H Type REF
4.5 1.0 Hex RAB 45 THG
4.5 1.0 Non-hex RAB 45 TNG
Ti-Temporary Abutment
Diameter G/H Type REF
4.5 2.0 hex RAB 45 20 PHL
4.5 2.0 Non-hex RAB 45 20 PNL
5.5 2.0 hex RAB 55 20 PHL
5.5 2.0 Non-hex RAB 55 20 PNL
6.5 2.0 hex RAB 65 20 PHL
6.5 2.0 Non-hex RAB 65 20 PNL
Hex
4.5
10
1.0
4.54.5
8.0
2.0
Non-hexhex
G/H 1.0
10
4.5
RAB45TH/NG and FX4510SWC
G/H 2.0
8.0
4.5
RAB4520PH/NL and FX4510SWC
Non-hex
4.5
10
1.0
5.55.5
8.0
2.0
Non-hexhex
6.56.5
8.0
2.0
Non-hexhex
Unit: mm
Scale 1 : 1.5 / mm• Abutment screw is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog36
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 37
Prosthetic Procedure 3
Screw Abutment
Open Tray Technique Closed Tray Technique
Screw-Retained Restoration
Abutment Level Impression
Screw Abutment4.5 / 5.5Page 38
Analog4.5 / 5.5
Page 40
Impression Coping TransferBridge / Single 4.5 / 5.5
Page 39
Polishing Protector4.5 / 5.5
Page 40
Ti-Retaining ScrewPage 40
Impression Technique and Restoration Selection
Impression Coping Pick-upBridge / Single 4.5 / 5.5
Page 39
Metal Cylinder4.5 / 5.5
Page 41
Gold Cylinder4.5 / 5.5
Page 41
Burn-out Cylinder4.5 / 5.5
Page 41
Bridge(Non-hex)
Single(Hex)
Temporary Restoration
Titanium Cylinder4.5 / 5.5
Page 41
Single(Hex)
Bridge(Non-hex)
Bridge(Non-hex)
Single(Hex)
Bridge(Non-hex)
Single(Hex)
SuperLine & Implantium Product Catalog 37
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 38
Screw Abutment
Diameter 4.5
G/H 3.5
5.5
SAB5535L and FX4510SWC
G/H REF
1.0 SAB45 10 L
1.5 SAB45 15 L
2.5 SAB45 25 L
3.5 SAB45 35 L
4.5 SAB45 45 L
5.5 SAB45 55 L
1.0 1.5 2.5 3.5 4.5 5.5
1.5 2.5 3.5 4.5 5.5
Diameter 5.5 G/H REF
1.5 SAB55 15 L
2.5 SAB55 25 L
3.5 SAB55 35 L
4.5 SAB55 45 L
5.5 SAB55 55 L
G/H
G/H
G/H
G/H
Unit: mm
Scale 1 : 1.5 / mm• Delivery Holder is included.
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
Delivery Holder
SuperLine & Implantium Product Catalog38
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 39
Impression Coping Pick-up Diameter Type REF
4.5 Single Hex SPU 45 SL
4.5 Bridge Non-hex SPU 45 BL
5.5 Single Hex SPU 55 SL
5.5 Bridge Non-hex SPU 55 BL
Diameter Type REF
4.5 Single Hex STF 45 SL
4.5 Bridge Non-hex STF 45 BL
5.5 Single Hex STF 55 SL
5.5 Bridge Non-hex STF 55 BL
Type REF
Pick-up SPS 15
Transfer STS 09
Impression Coping Screw
Screw Abutment Impression ComponentsUnit: mm
Scale 1 : 1.5 / mm
4.54.5
5.55.5
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
4.54.5
5.55.5
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
15.0
9.0
• Impression Coping Screw is included with impression coping.
Impression Coping Transfer
SuperLine & Implantium Product Catalog 39
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 40
Screw Abutment Impression Components
Diameter REF
4.5 SAN 45 L
5.5 SAN 55 L
5.5Analog 4.5
5.5
Polishing Protector4.5
SRS 18 T
Ti-Retaining Screw
Diameter REF
4.5 SPP 45 L
5.5 SPP 55 L
5.5
Comfort Cap4.5 Diameter REF
4.5 SCC 45 L
5.5 SCC 55 L5.0 5.0
12.0 12.0
1.8
2.3
Unit: mm
Scale 1 : 1.5 / mm
• Ti-Retaining screw is included.1.8
2.3
SuperLine & Implantium Product Catalog40
REF
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 41
Burn-out Cylinder Diameter Type REF
4.5 Single Hex
4.5 Bridge Non-hex
5.5 Single Hex
5.5 Bridge Non-hex
Screw Abutment Components
Gold Cylinder
4.54.5
5.55.5
5.55.5
4.54.5
Diameter Type REF
4.5 Single Hex
4.5 Bridge Non-hex
5.5 Single Hex
5.5 Bridge Non-hex
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
12.0 12.0
12.0 12.0
12.0 12.0
12.0 12.0
1.8
1.8
1.8
1.8
2.3
2.3
Metal Cylinder I Co-Cr
4.54.5
5.55.5
Diameter Type REF
4.5 Single Hex
4.5 Bridge Non-hex
5.5 Single Hex
5.5 Bridge Non-hex
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
12.0 12.0
12.0 12.0
1.8
1.8
2.3
2.3
2.3
2.3
5.55.5
Ti-Cylinder
4.54.5
Diameter Type REF
4.5 Single Hex
4.5 Bridge Non-hex
5.5 Single Hex
5.5 Bridge Non-hex
Bridge (Non-hex)Single (Hex)
Bridge (Non-hex)Single (Hex)
8.7
3.3
8.7
3.3
8.7
3.3
8.7
3.3
1.8
1.8
2.3
2.3
Unit: mm
Scale 1 : 1.5 / mm• Ti-Retaining screw is included with cylinders.
Note : 10N cm of torque is recommended for cylinders.
STC 45 SG
STC 45 BG
STC 55 SG
STC 55 BG
SBC 45 SL
SBC 45 BL
SBC 55 SL
SBC 55 BL
SGC 45 SL
SGC 45 BL
SGC 55 SL
SGC 55 BL
SGC 45 CSL
SGC 45 CBL
SGC 55 CSL
SGC 55 CBL
SuperLine & Implantium Product Catalog 41
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 42
Prosthetic Procedure 4Impression Technique and Restoration Type
Overdenture Procedure
Ball Attachment
Ball Abutment3.5
Page 43
Abutment Level Impression
Ball Impression CopingPage 43
Ball AnalogPage 43
Socket SpacerPage 43
Female Socket and O-ringPage 43
SuperLine & Implantium Product Catalog42
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 43
Ball Attachment
Ball Impression Coping
Ball Analog
BAB352018 and FX4510SWC
Female Socket
G/H 2.0
2.9
4.05
Ball Abutment G/H REF
0 BAB 35 0018
1.0 BAB 35 1018
2.0 BAB 35 2018
3.0 BAB 35 3018
4.0 BAB 35 4018
5.0 BAB 35 5018
4.0
1.8
3.5
3.0
1.8
3.5
2.0
1.8
3.5
1.0
1.8
3.5
1.8
3.3
5.0
1.8
3.5
Socket Spacer
REF BIC3L
7.5
3.8
(300~500gf) (500~700gf)
(BFS3) (BNO1) (BFS2) (BNO2)
4.05 4.85
2.9 3.3 REF
BPF3 (300~500gf)
BPF2 (500~700gf)
REF BANL
REF ICA
Unit: mm
Scale 1 : 1.5 / mm
Note : 1) If using a 3.6 platform/3.4 body fixture, the abutment height will be 0.5mm higher than other fixture diameters. 2) 25~30N.cm of torque is recommended for final restoration seating.
SuperLine & Implantium Product Catalog 43
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 44
Surgical Kit [Full]
Kit Contents
Countersink XCS 36 29 SW
XCS 40 29 SW
XCS 45 29 SW
XCS 50 29 SW
XCS 60 29 SW
XCS 70 29 SW
Hand-piece adapter
Ratchet adapter
Parallel pin x4
Path pin x2
Depth gauge
Hex driver
Ratchet
Drill extension
XPP 162220 T
XID 27 H
XID 32 H
XID 26 W
XID 32 W
XMFPA2
XHD 26 T
XDE
XDGL
XRCA1
Final drill (Stopper) XFD 34 35
XFD 38 35
Final drill XFD 34 29
XFD 38 29
XFD 43 29
XFD 48 29
XFD 58 31
Lindemann guide drill XLD 22 29
XLD 26 29Lindemann first drill
XLD 22 35
XLD 26 35
(Stopper)
(Stopper)
XFD 43 35
XFD 48 35
REF UXIF
SuperLine & Implantium Product Catalog44
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 45
Drill Stopper Kit
Kit Contents
Lindemann drill stopper
XLD 22 35
XLD 26 35
Final drill stopper / 34, 38
XFD 34 35
XFD 38 35
Stopper-lindemann drill
Stopper-final drill / 34, 38
XLDST 14 XLDST 12 XLDST 10 XLDST 08 XLDST 06
XFDST 14 XFDST 12 XFDST 10 XFDST 08 XFDST 06
Final drill stopper / 43, 48
XFD 43 35
XFD 48 35
Stopper-final drill / 43, 48
XFDST 14L XFDST 12L XFDST 10L XFDST 08L XFDST 06L
REF XDS
SuperLine & Implantium Product Catalog 45
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 46
Drill
Guide Drill
Pilot Drill1.93.0
30
1.528
Diameter L REF
1.5 20 XGD 15 20
1.5 28 XGD 15 28
1.520
Diameter L REF
3.0 30 XPD 20 30
First Drill2.0
33 Diameter L REF
2.0 33 XFD 20 33
33
33
Lindemann Guide Drill
Diameter L REF
2.2 29 XLD 22 29
2.2 31 XLD 22 31
2.2 33 XLD 22 33
2.2 35 XLD 22 35
2.2 41 XLD 22 41
Lindemann First Drill
Diameter L REF
2.6 29 XLD 26 29
2.6 31 XLD 26 31
2.6 33 XLD 26 33
2.6 35 XLD 26 35
2.6 41 XLD 26 41
2.352.6
1.72.2
1.72.2
35
2.352.6
29
1.72.2
29
2.352.6
31
1.72.2
31
2.352.6
41
1.72.2
41
2.352.6
35
Unit: mm
Scale 1 : 1.5 / mm
8 10 12 14 16
SuperLine & Implantium Product Catalog46
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 47
Diameter L REF
2.85 29 XFD 34 29
3.3 29 XFD 38 29
3.85 29 XFD 43 29
4.4 29 XFD 48 29
5.4 29 XFD 58 29SW
Final Drill | Length-29mm
Diameter L REF
2.85 33 XFD 34 33
3.3 33 XFD 38 33
3.85 33 XFD 43 33
4.4 33 XFD 48 33
Final Drill | Length-33mm
12
29
16
33
Diameter L REF
2.85 31 XFD 34 31
3.3 31 XFD 38 31
3.85 31 XFD 43 31
4.4 31 XFD 48 31
5.4 31 XFD 58 31
Final Drill | Length-31mm2.85
3.3
3.85
14
4.4
2.85
3.3
3.85
4.4
5.4
31
2.85
3.3
3.85
4.4
5.4
Unit: mm
Scale 1 : 1.5 / mm
Drill SuperLine & Implantium Product Catalog 47
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 48
Drill
Diameter L REF
2.85 35 XFD 34 35
3.3 35 XFD 38 35
3.85 35 XFD 43 35
4.4 35 XFD 48 35
Final Drill Length-35mm | Stopper
2.0
3.0
35
3.6
4.0
4.5
5.0
29
Countersink6.0
7.0
Diameter REF
3.6 XCS 36 29 SW
4.0 XCS 40 29 SW
4.5 XCS 45 29 SW
5.0 XCS 50 29 SW
6.0 XCS 60 29 SW
7.0 XCS 70 29 SW
Round Bur
27
Diameter L REF
2.85 41 XFD 34 41
3.3 41 XFD 38 41
3.85 41 XFD 43 41
4.4 41 XFD 48 41
Diameter L REF
2.0 33 XRB 20 33
3.0 33 XRB 30 33
Final Drill Length-41mm2.85
3.3
3.85
4.4
16
41
2.85
3.3
3.85
4.4
Unit: mm
Scale 1 : 1.5 / mm
SuperLine & Implantium Product Catalog48
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 49
Stopper
Drilling Depth L REF
14 4.6 XLDST 14
12 6.6 XLDST 12
10 8.6 XLDST 10
08 10.6 XLDST 08
06 12.6 XLDST 06
04 14.6 XLDST 04
02 16.6 XLDST 02
XLDST14
Stopper | For Lindemann Guide, First Drill
XLDST12XLDST10
XLDST08XLDST06
4.45 4.45 4.45 4.45 4.45
12.610.68.66.6
4.6
Drilling Depth L REF
14 4.6 XFDST 14
12 6.6 XFDST 12
10 8.6 XFDST 10
08 10.6 XFDST 08
06 12.6 XFDST 06
04 14.6 XFDST 04
02 16.6 XFDST 02
Stopper | For Final Drill 3435, 3835
14.6 16.6
4.45 4.45
XFDST14XFDST12
XFDST10XFDST08
XFDST06
5.14 5.14 5.14 5.14 5.14
12.610.68.66.6
4.6
14.6 16.6
5.14 5.14
XLDST04 XLDST02
XFDST04 XFDST02
Drilling Depth L REF
14 4.6 XFDST 14L
12 6.6 XFDST 12L
10 8.6 XFDST 10L
08 10.6 XFDST 08L
06 12.6 XFDST 06L
04 14.6 XFDST 04L
02 16.6 XFDST 02L
Stopper | For Final Drill 4335, 4835
XFDST14LXFDST12L
XFDST10LXFDST08L
XFDST06L
6.14 6.14 6.14 6.14 6.14
12.610.68.66.6
4.6
14.6 16.6
6.14 6.14
XFDST04L XFDST02L
Unit: mm
Scale 1 : 1.5 / mm
SuperLine & Implantium Product Catalog 49
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 50
Instrument
Parallel Pin | For Lindemann Drill
Diameter REF
1.6 XPP 162220T
1.6 XPP 162226T
Path Pin
20
26
1.6
1.6
L REF
18.6 XMFPA2 18.6
Adapter | Hex 1.28mm
Type L REF
27 XID 27 H
Hand-piece 30 XID 30 H
32 XID 32 H
24 XID 24 W
26 XID 26 W
29 XID 29 W
32 XID 32 W
32
32
29
26
24
27
30
Ratchet
Unit: mm
Scale 1 : 1.5 / mm
SuperLine & Implantium Product Catalog50
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 51
Instrument
Hex Driver | Hex 1.28mm
Slot Driver
Type L REF
Hand-piece 25 XHD 25 H
21 XHD 21 W
25 XHD 25 W
27 XHD 27 W
26 XHD 26 T 30 XHD 30 T
Type REF
SDA 17 R
SDA 25 R
25
30
26
25
17
Driver | Manual
Type REF
Manual XHDHT
21
12
Drill Extension
REF26
Ratchet
27
25
Ratchet
XDE
Unit: mm
Scale 1 : 1.5 / mm
Manual [w/ wheel ]
SuperLine & Implantium Product Catalog 51
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 52
Instrument
Adapter | For screw Abutment Scale 1 : 1 / mm
Ratchet
Torque Wrench | Scale 1 : 0.7 / mm
Depth Gauge
Note : One side of Depth Gauge measures the osteotomy
depth and the other side measures the gingival
height from the top of the implant.
Type REF
Hand-piece XMAA1
Ratchet XMA 21W
20
21
Tissue Punch | Scale 1 : 1 / mm
Punching size : 4.0
Adapter | For ball abutment | Scale 1 : 1 / mm
21 REF IPST21W
REF XRCA1
REF XNTW
REF XDGL
REF XTS40
Unit: mm
SuperLine & Implantium Product Catalog52
4.0
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 53
DASK [Dentium Advanced Sinus Kit]
XFDST08
Kit Contents
DASK drill XRT332035
XED331035D
XRT372035
XRT064025
XRT084025
XST083025
Stopper
XFDST 08 XFDST 06 XFDST 04 XFDST 02
Sinus elevation instrumentXSE1L
XSE2L
XSE3L
XSE4L
REF DASK
SuperLine & Implantium Product Catalog 53
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 54
Sinus Bur Kit / Sinus Kit
XRT083025
Kit Contents
DASK Drill XRT332035
XED331035D
XRT372035
XRT064025
XRT084025
XST083025
Stopper XFDST 08 XFDST 06 XFDST 04 XFDST 02
(XSE1L)
(XSE2L)
(XSE3L)
(XSE4L)
REF SDK
REF XSKL
SuperLine & Implantium Product Catalog54
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 55
DASK / Sinus Bur Kit / Sinus Kit
XRT332035
XED331035D
3.3
24681012
3.3
0
24681012 1 0
XRT372035 3.7
24681012 0
XRT064025
DASK Drill | Scale 1 : 1.2 / mm
XRT084025
XST083025
6.0
4.0
8.0
8.0
1.5 1.5
XFDST08XFDST06
XFDST04
5.145.14 5.14 5.14
14.612.610.6
16.6
XFDST02
Drilling Depth L REF
08 10.6 XFDST 08
06 12.6 XFDST 06
04 14.6 XFDST 04
02 16.6 XFDST 02
Stopper | For XRT332035, XRT372035, XED331035D | Scale 1 : 1 / mm
6.6
Sinus Elevation Instrument | Scale 1 : 0.45 / mm
XSE1L
XSE2L
XSE3L
XSE4L
Note : Drill speed 800 to 1,200rpm, 30~45N.cm with irrigation.
Crestal Approach
Type DASK Drill # REF
DASK Drill #1 XRT 332035
DASK Drill #2 XRT 372035
DASK Drill #3 XED 331035D
DASK Drill #4 XRT 064025
DASK Drill #5 XRT 084025
DASK Drill #6 XST 083025
Lateral Approach
4.0
SuperLine & Implantium Product Catalog 55
Unit: mm
Product Catalog Final 2012_Layout 1 9/11/12 8:54 AM Page 56
Osteotome Kit
A B
Osteotome Kit
Osteotome compresses the bone laterally, providing a denser bony interfacerather than removing valuable bone from the surgical site.
Osteotome Kit
XOF 20 A1
XOF 34 A1
XOF 38 A1
XOF 43 A1
XOF 48 A1
XOF 20 B1
XOF 34 B1
XOF 38 B1
XOF 43 B1
XOF 48 B1
Osteotome | Final drill type | Scale 1 : 0.4 / mm
Type REF A B
XOF 20 A1 1.7 2.8
XOF 34 A1 2.3 2.8
XOF 38 A1 2.7 3.2
XOF 43 A1 2.8 3.8
XOF 48 A1 3.0 4.3
XOF 20 B1 1.7 2.8
XOF 34 B1 2.3 2.8
XOF 38 B1 2.7 3.2
XOF 43 B1 2.8 3.8
XOF 48 B1 3.0 4.3
Type B
Type A
A B
XOFBK
Type A(Convex)
Type B(Concave)
(Convex)
(Concave)
XOFK
XOFK (Type A)
XOFBK (Type B)
Unit: mm
SuperLine & Implantium Product Catalog56
REF
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 57
Trephine Kit
Trephine Bur
• Excellent fine cutting• Strong engagement of the trephine to cortical bone• Cut-outs facilitate ease of harvest retrieval.• 5 depth marks on the trephine drill from 2mm to 10mm• Easy harvesting
3723
14 108642
Outer Inner Diameter Diameter
3.0 2.3 XTP 24 03
4.0 3.3 XTP 34 04
5.0 4.2 XTP 44 05
6.0 5.2 XTP 54 06
7.0 6.1 XTP 64 07
8.0 7.1 XTP 74 08
9.0 8.0 XTP 84 09
10.0 9.0 XTP 94 10
REF
Trephine Bur | Scale 1 : 0.5 / mm 3.0
2.3
5.0
4.2
7.0
6.1
9.0
8.0
4.0
3.3
6.0
5.2
8.0
7.1
10.0
9.0
Trephine Kit | Complete
Front View
Side View
Front View
Side View
Front View
Side View
Front View
Side View
Front View
Side View
Front View
Side View
Front View
Side View
Front View
Side View
REF XIT
Outer
Inner
Outer
Inner
Outer
Inner
Outer
Inner
Outer
Inner
Outer
Inner
Outer
Inner
Outer
Inner
Unit: mm
SuperLine & Implantium Product Catalog 57
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 58
Prosthetic Kit
Hex Driver S/T Scale 1 : 1 / mm
B.WRENCHADAPTER
Slot Driver Scale 1 : 1 / mm
Hex Driver T/W Scale 1 : 1 / mm
Hex Driver L/T Scale 1 : 1 / mm
Mount Adapter Scale 1 : 1 / mmFor Screw Abutment with Hand-Piece
T/W Adapter Scale 1 : 1 / mmFor Screw Abutment with Torque Wrench
Ball Adapter Scale 1 : 1 / mmFor Ball Abutment with Torque Wrench
REF XHD 15
REF IPST 21 W
REF XHD 25 W REF XMAA1
REF XMA 21 W
REF XNTW
Torque Wrench Scale 1 : 0.5 / mm
REF XIP
SuperLine & Implantium Product Catalog58
Unit: mm
REF SDA 25 R REF XHD 30 T
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 59
Planning Kit
Diameter 4.5 | Combi & Dual Abutment
G/H REF
1.5 PDAB 45 15
2.5 PDAB 45 25
3.5 PDAB 45 35
4.5 PDAB 45 45
5.5 PDAB 45 55
Diameter 5.5 | Combi & Dual Abutment
G/H REF
1.5 PDAB 55 15
2.5 PDAB 55 25
3.5 PDAB 55 35
4.5 PDAB 55 45
5.5 PDAB 55 55
Angled 15° | Angled Abutment
Diameter G/H REF
4.5 2.0 PAAB 15 45 20
4.5 4.0 PAAB 15 45 40
5.5 2.0 PAAB 15 55 20
5.5 4.0 PAAB 15 55 40
Angled 25° | Angled Abutment
Diameter G/H REF
4.5 2.0 PAAB 25 45 20
4.5 4.0 PAAB 25 45 40
5.5 2.0 PAAB 25 55 20
5.5 4.0 PAAB 25 55 40
Diameter 6.5 | Combi & Dual Abutment
G/H REF
1.5 PDAB 65 15
2.5 PDAB 65 25
3.5 PDAB 65 35
4.5 PDAB 65 45
5.5 PDAB 65 55
1.5
G/H2.5 3.5 4.5 5.5
5.5
1.5 2.5 3.5 4.5 5.5
152.0
G/H
152.0
154.0
154.0 2.0
252.0
252.0
254.0
254.0
G/H G/H
1.5 2.5 3.5 4.5
G/H
Unit: mm
Scale 1 : 1 / mm
REF XPK
SuperLine & Implantium Product Catalog 59
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 60
Prosthetic and Laboratory Instrument
Reamer Guide | For Screw Abutment
Diameter REF
4.5 CRG 45 L
5.5 CRG 55 L
6.5 CRG 65 L
Reamer Guide | For Combi / Dual Abutment
4.5
5.5
6.5
Bridge
Single
Type REF
Bridge SRG BL
Single SRG SL
Hex driver | Hex 1.28mm
Type L REF
21 XHD 21 T
28 XHD 28 T
13 XHD 13
15 XHD 15
21 XHD 21
28 XHD 28
Manual[w/ wheel]
Manual[w/o wheel]
15 21 2813
21 28
Unit: mm
Scale 1 : 1 / mm
SuperLine & Implantium Product Catalog60
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 61
Prosthetic and Laboratory Instrument
Reamer Handle | Scale 1 : 0.5 / mm
Hand Wrench | Scale 1 : 1 / mm
Reamer (For Combi / Dual Abutment) | Scale 1 : 1 / mm
Reamer (For Screw Abutment) | Scale 1 : 1 / mm
REF CRH
REF XHW
REF CRM
REF SRM
Unit: mm
SuperLine & Implantium Product Catalog 61
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 62
Help Kit
Screw Remover
L REF
25 XRFS2S
33 XRFS2
25
33
Abutment Hex Remover
L REF
20 XRHR20
25 XRHR25
2025
Screw Tap Repair
Type REF
Tap XRSTR
11° Guide XRSG11
8 ° Guide XRSG8
25 11°
8°
25
Cover & Abutment Screw Remover L REF
25 XRRHD
Fixture Remover
Type REF
XRFRT
Remover XRFRTF
XRFRTO
Wrench XRFRW
25
Wrench
25 25
REF XIH
SuperLine & Implantium Product Catalog62
Unit: mm
Scale 1 : 1 / mm
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 63
Surgical Kit Maintenance
Sterilization and Instrument Care Procedures
• Please follow legal regulations, as well as hygienic guidelines to prevent contamination andinfection through prevention.
• Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. It is important to use and follow proper cleaning, disinfection andsterilization procedures.
• It is also important to follow the manufacture!s recommendation on the usage of drills. Pleasekeep a log as to how many times the drills are used.
• Drills are used per implant placed not per patient. Bone density determines the life of the drills.• Replace white and red o-rings on adapters and hex drivers, if worn and dried out.• Drills should be considered for replacement around 40 uses based on bone density.
01 All instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak over-night.
02 Scrub with a soft brush to remove any debris.03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 to prevent rubbing against each other.05 Rinse thoroughly under warm water.06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.07 Dry completely and place back into kit.08 Always check for damage or corrosion after rinsing and drying.09 Seal the tray in a sterilization pouch.10 Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufactures
recommendtions.11 Store in a dry area at room temperature.
Maintenance Period for Surgical Drills
(1000rpm, 30~45N·cm with Irrigation)
All surgical drills shall be replaced after approximately 40 uses based on bone density.
(1000rpm, 30~45N·cm with Irrigation)
Depending on bone density, the rpmcould be abjusted
(1000rpm, 30~45N·cm with Irrigation)
Cover & Abutment Screw Remover
Lindermann Guide Drill
Lindermann First Drill
Final Drill
Countersink Drill
SuperLine & Implantium Product Catalog 63
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 64
DASK Maintenance
Sterilization and Instrument Care
Maintenance Period for DASK Drills
(800 ~1,200rpm, 30~45N.cm with internal irrigation)
All surgical drills shall be replaced with new one after approximately 20 uses based on bone density.
(800 ~1,200rpm, 30~45N.cm with internal irrigation)
(800 ~1,200rpm, 30~45N.cm with internal irrigation)
(800 ~1,200rpm, 30~45N.cm with internal irrigation)
(800 ~1,200rpm, 30~45N.cm with internal irrigation)
(800 ~1,200rpm, 30~45N.cm with external irrigation)
• Please follow legal regulations, as well as hygienic guidelines to prevent contamination andinfection through prevention.
• Please remember that you are responsible for the maintenance and sterility of your medical/dental products/device. It is important to use and follow proper cleaning, disinfection andsterilization procedures.
• It is also important to follow the manufacture!s recommendation on the usage of drills. Pleasekeep a log as to how many times the drills are used.
• Drills are used per implant placed not per patient. Bone density determines the life of the drills.• Replace white and red o-rings on adaptes and hex drivers, if worn and dried out.• Drills should be considered for replacement around 20 uses based on bone density.
01 All instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen and prevent debris from attaching to instruments. Do not soak over-night.
02 Scrub with a soft brush to remove any debris.03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 to prevent rubbing against each other.05 Rinse thoroughly under warm water.06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.07 Dry completely and place back into kit.08 Always check for damage or corrosion after rinsing and drying.09 Seal the tray in a sterilization pouch.10 Sterilize using a steam autoclave in 121°C/250F for 30 minutes or refer to manufactures
recommendations.11 Store in a dry area at room temperature.
SuperLine & Implantium Product Catalog64
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 65
The followings are the terms and conditions under which Dentium USA sells its products.
Governing Terms :Any shipment of product shall be deemed to be according to the terms and conditions stated herein. Anyand all terms and conditions submitted by Purchaser are hereby rejected. Taxes : The prices set forth herein do not include any sale, use, excise, ad valorem, property or other taxesapplicable to the sale, use or delivery of the products, all of which shall be paid by Purchaser separatelyor added to the contract price and paid by Purchaser to Dentium USA. Pricing : The prices set forth for the products are in United States Dollars. Prices are subject to change without notice. Payment : Payment terms shall be as set forth under the “Terms” section on the front of the invoice. Delivery : Products sold hereunder shall be delivered F.O.B. manufacturer!s plant or distributor!s plant, as applicable.Purchaser shall assume reponsibility for all subsequent delivery or shipping charges.
Warranty : Dentium USA or any of its affiliates makes no warranty, express or implied, except that its products shall befree from defects in material and workmanship. This warranty applies only to the original Purchaser and isnon-transferable. In the event of a product defect, please immediately notify Dentium USA of the defectprior to returning the product. Devices shall be sterilized prior to return. As its sole obligation and asPurchaser!s sole remedy under this warranty, Dentium USA"will at its option, either repair, replace or issuecredit for such product. Purchaser assumes all risks and liability resulting from the use of these products,whether used separately or in combination with other products.
Education; Modification of Products : Dentium USA"strongly recommends completion of formal post graduate implant education and strictadherence to the procedures described in Dentium USA!s implant instruction manuals. Dentium USAcontinuosly strives to improve its products and therefore reserves the right to improve, modify or discontinueproducts at any time, or to change specifications of the products without notice and without incurring any obligation.
Return Policy : A Purchaser may return any unopened Dentium USA product that is in its original packaging within90 days of the invoice date. Dentium USA products returned within 30 days of the invoice date willbe accepted without any restocking fee to the purchaser. Dentium USA products returned between31 and 90 days of invoice date will be subjected to 15% re-stocking fee.
No returns will be permitted over 90 days from invoice date. To return an item, contact your local salesrepresentative or call Dentium USA Customer Service Department for a Return Material Authorization(RMA) number. Issuance of a RMA number does not guarantee that the product will be accepted forreturn. No product returns will be accepted without a RMA number. Dentium USA product will beaccepted for return only if the Dentium USA product is (1) returned in its original, unopened package(including autoclavable products); (2) received by Dentium USA within 90 days after the invoice datefor that product; and (3) returned freight prepaid and accompanied by the Dentium USA RMAnumber. (4) implants and prosthetic parts being returned for credit or exchange must have at leasta 6 month shelf life remaining. Individual items from a kit cannot be returned for credit.
Previously exchanged items cannot be returned for credit. Please do not give any item(s) to bereturned to your local Sale Representative. All products must be sent directly to the ReturnsDepartment of Dentium USA. Procedures and policies as stated are subject to change without priornotice.
Terms and Conditions of sale
SuperLine & Implantium Product Catalog 65
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 66
Terms and Conditions of sale
Dentium USA Customer ServiceMonday - Friday 8:30 am –5:30 pm (PST)
Phone : 1-877-304-6752Fax: 1-714-226-0019
Ema i l :[email protected]
Exchange Policy :Dentium USA products may be exchanged within 180 days of the invoice date, without a re-stockingfee, for other Dentium USA products of equal or lesser value within the same product family asdetermined by Dentium USA (ex. implant for implant, abutment for abutment, bone graft materialfor bone graft material). Dentium USA products may be exchanged within 180 days of the invoicedate for other Dentium USA!products of greater value within the same product family as determinedby Dentium USA (ex. implant for implant, abutment for abutment, bone graft material for bone graftmaterial) with the price differential paid by the Purchaser. In both cases, the exchanged DentiumUSA product must be (1) returned in its original, unopened package (including autoclavable products);(2) a currently offered Dentium USA!product ( discontinued product not included); (3) returnedfreight prepaid and accompanied by the Dentium Return Material Authorization number providedby Dentium USA"s Customer Service Department. Licenses, permits and export control :The timely securing of permits, licenses or other local, state or federal governmental approvals required inconnection with Purchaser!s use of any product hereunder shall be the sole responsibility of Purchaser andPurchaser shall bear the cost thereof. Unless otherwise agreed between Dentium USA and Purchaser,products sold hereunder are only for use in the United States. Purchaser agrees that Purchaser will complyfully with all applicable state and federal laws and regulation and Purchaser shall indemnify Dentium USAfor all losses, damages and penalties incurred as a result of any violation of applicable state or federal lawor regulations. Force Majeure :Dentium USA shall not be liable for any loss or damage due to failure or delay arising out of any causebeyond the reasonable control of Dentium USA. In the event of any failure or delay resulting from suchcauses, an equitable adjustment of delivery and any other appropriate terms and conditions shall be made.No such failure or delay shall be the basis for an increase in neither Dentium USA!s obligations nor anytermination by Purchaser. Limitation of Liability :Except for the warranty expressly described in the “Warranty” paragraph above, neither Dentium USA norany of its affiliates makes any other warranty with respect to the Dentium USA products, express or implied,written or oral including, without limitation, any implied warranty of merchantability, or a warranty of fitnessfor a particular purpose. Neither Dentium USA nor any of its affiliates shall be liable for business interruption,loss of profits, special, indirect, incidental or consequential damages of any nature and from any causewhether based in contract, tort ( including negligence) or other legal theory, even if Dentium USA or any ofits affiliates has been advised of the possibility of such damages. Validity :If any provision of these Terms and conditions is found to be illegal or unenforceable in any respect, suchillegality or unenforceability shall not affect any other provision of these Terms and Conditions, all of whichshall remain enforceable in accordance with their terms. General Provisions :The Purchase of the products and these Terms and Conditions are governed by the laws of California,without regard to conflicts of law principles. This document incorporates all oral and written representationsbetween the parties and constitutes the entire agreement and understanding of the parties with respect tothe subject matter hereof and supersedes any and all other agreements either oral or written between theparties with respect to such subject matter. No amendment or modification may be made to this documentunless in writing and duly executed by an authorized representative of Dentium USA. Caution :Federal ( U.S ) Law restricts these devices to sale by or on the order of a licensed healthcare practitioner.Devices labeled “Sterile” are certified to be sterile unless package is opened or damaged. Patent Notice :Dentium USA products are protected by patents issued by the United States of America and other countries.
SuperLine & Implantium Product Catalog66
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 67
Copyright 2012. DENTIUMUSA
Product Catalog Final 2012_Layout 1 9/11/12 8:55 AM Page 68
L.A. Office / MFG6761 Katella Ave. Cypress, CA 90630 Tel. 1-877-304-6752 Fax. 714-226-0019N.Y. Office180 Sylvan Ave. Englewood Cliffs, NJ 07632 Tel. 201-402-1390 Fax 201-731-3042Website / E-mailwww.dentiumusa.com , [email protected]
®™SuperLine & ImplantiumProduct Catalog
Specifications are subject to change without prior notice. Some products to be launched in the market after necessary approvals are also listed in this catalog.
PN2432 - 03
Product Catalog Final 2012_Layout 1 9/11/12 8:45 AM Page 1