Supastor SS Direct unvented cylinders - Flamco Group · Property Type Bedsit 1/2 beds with 1...
Transcript of Supastor SS Direct unvented cylinders - Flamco Group · Property Type Bedsit 1/2 beds with 1...
Direct HeightDiameterWeight (Dry kg)Weight (Normal Full kg)T&P TappingT&P Pressure SettingT&P Temperature SettingExpansion Relief SettingElectrical Heater QuantityElectrical Heater RatingRe-heat Times (2x3 kW)Heat Up Time (From Cold)Expansion Vessel
97755520.81413/4”
7 bar95º
6 bar2
3 kW34 mins40 mins12 Ltr
116755523.51743/4”
7 bar95º
6 bar2
3 kW46 mins65 mins12 Ltr
134755526.52073/4”
7 bar95º
6 bar2
3 kW56 mins80 mins12 Ltr
1569555332433/4”
7 bar95º
6 bar2
3 kW69 mins98 mins12 Ltr
175955535.52863/4”
7 bar95º
6 bar2
3 kW80 mins114 mins
12 Ltr
1750606423423/4”
7 bar95º
6 bar2
3 kW101 mins144 mins
12 Ltr
182373459
5593/4”
7 bar95º
6 bar2
3 kW159 mins256 mins
12 Ltr
19609501009003/4”
7 bar95º
6 bar2
3 kW260 mins400 mins
24 Ltr
236095011511153/4”
7 bar95º
6 bar2
3 kW318 mins512 mins
24 Ltr
120 litres 150 litres 180 litres 1000 litres800 litres500 litres300 litres250 litres210 litresVolume (Nominal)
Supastor SS Direct unvented cylindersDirect unvented cylinders for potable water installations
Fluid Flow SequenceMains Water Isolation Valve (Not Supplied)3 bar Pressure Reducing ValveSafety Group (6 bar Expansion Relief Valve c/w Non Return Valve)Expansion VesselDrain Valve (Not Supplied)Stainless Supastor Hot Water Calorifier
Expansion Vessel
2 off 3 kW 230v/50HzImmersion Heater
Combined Temperature& Pressure Relief ValveFactory Fitted7 bar/95ºC
TundishSafety Group c/wNon Return Valve6 bar Relief
P re s s u re ReducingValve Pre-Set
Technical Specification Direct (including kit)
Insulation is interlocked polystyrene to allow for inspection of cylinder if required.
Supastor SS Direct unvented cylinders
120 to 300 litre 500 to 1000 litre
1750
606
47
1” BSP (M)
282
1532
1444
Top Centr e
1” BSP (F)
977
555
51
1” BSP (M)
289
749
644
Top Centr e
1” BSP (F)
1167
555
51
1” BSP (M)
289
939
834
Top Centr e
1” BSP (F)
1347
555
51
1” BSP (M)
289
1119
1014
Top Centre
1” BSP (F)
1569
555
51
1” BSP (M)
289
1341
1236
Top Centr e
1” BSP (F)
1759
555
51
1” BSP (M)
289
1531
1426
Top Centre
1” BSP (F)
1823
734
52
1” BSP (M)
317
1517
932
1517
1” BSP (F)
Height A (mm)
Diameter B (mm)
Cold Water C (mm)
Cold Water Connection
Immersion D (mm)
T&P Valve J (mm)
Immersion K (mm)
DHW Flow J
DHW Connection
120 Direct 150 Direct 180 Direct210 Direct250 Direct 3 0 0 Direct500 DirectVolume (Nominal)
Techn ica l Spec i f i cat ion Connect ions800 Direct 1000 Direct
1960
950
338
1 1/2”BSP (M)
343
1603
1103
1603
1 1/2”BSP (F)
2360
950
338
1 1/2” BSP (M)
343
2003
1103
2003
1 1/2” BSP (F)
Height A (mm)Diameter B (mm)Cold Water C (mm)Cold Water ConnectionImmersion D (mm)T&P Valve J (mm)Immersion K (mm)DHW Flow JDHW Connection
97755551
1” BSP (M)289749644
Top Centre1” BSP (F)
116755551
1” BSP (M)289939834
Top Centre1” BSP (F)
134755551
1” BSP (M)28911191014
Top Centre1” BSP (F)
156955551
1” BSP (M)289
13411236
Top Centre1” BSP (F)
175955551
1” BSP (M)28915311426
Top Centre1” BSP (F)
175060647
1” BSP (M)28215321444
Top Centre1” BSP (F)
182373452
1” BSP (M)31715179321517
1” BSP (F)
1960950338
1 .1 / 2” BSP (M)343160311031603
1 .1 / 2” BSP (F)
2360950338
1 .1 / 2” BSP (M)343200311032003
1 .1 / 2” BSP (F)
120 litresDirect
150 litresDirect
180 litresDirect
1000 litresDirect
800 litresDirect
500 litresDirect
300 litresDirect
250 litresDirect
210 litresDirectVolume (Nominal)
Technical Specification Direct (including kit)
A
B B
A
CD
K
JJ
K
D
120 to 300 litre 500 to 1000 litre
Property TypeBedsit1/2 beds with 1 bath/shower3 beds with 1 bath/shower4 beds with 1 bath/shower2/3 beds with 2 baths/showers4/5 beds with 2 baths/showersSports club, Restaurant etc.Hotels, Schools etc.
Indirect Size
120 150 or 180180 or 210210210 or 250300 or 500800 or 1000
•In areas with high concentration ofChlorine (200 ppm or above) additionalprotection of the cylinder is requiredwith an electrical anode.
This is an optional extra and is notreflected in the pricing.
VesselsIndirect vessels can be suppliedwithout kits asa storage vessel
Selection Guide
Indirect HeightDiameterWeight (Dry kg)Weight (Normal Full kg)T&P TappingT&P Pressure SettingT&P Temperature SettingExpansion Relief SettingElectrical Heater QuantityElectrical Heater RatingRe-heat Times (82º Supply)Heat Up Times (From Cold)Max. Primary Pressure (Coil)Primary Flow Rate (Boiler L/min)Primary Resistance (mbar)Continuous Output (mbar)Coil Rating kWExpansion Vessel
116755527
1773/4”
7 bar95º
6 bar1
3 kW20 mins31 mins16 bar
34141.949326.2
12 Ltr
1347555302103/4”
7 bar95º
6 bar1
3 kW25 mins37 mins16 bar
34141.930
49326.2
12 Ltr
156955538
2483/4”
7 bar95º
6 bar1
3 kW22 mins27 mins16 bar
42324.862733.4
12 Ltr
1759555412913/4”
7 bar95º
6 bar1
3 kW24 mins30 mins16 bar
42354.668436.4
12 Ltr
1750606503503/4”
7 bar95º
6 bar1
3 kW20 mins25 mins16 bar
49987.598552.4
12 Ltr
250 litres 300 litres 1000 litres800 litres500 litresVolume (Nominal)
976555231433/4”
7 bar95º
6 bar1
3 kW17 mins29 mins16 bar
2564.946424.7
12 Ltr
210 litres
2360950
124.512453/4”
7 bar95º
6 bar2
3 kW40 mins49 mins16 bar
921287.0169590.2
24 Ltr
1960950
110.59113/4”
7 bar95º
6 bar2
3 kW31 mins40 mins16 bar
921287.0169590.2
24 Ltr
182373468.55693/4”
7 bar95º
6 bar1
3 kW31 mins38 mins16 bar
67509.8105956.4
12 Ltr
180 litres150 litres120 litres
Expansion Vessel
2 off 3 kW 230v/50HzImmersion Heater
Combined Temperature& Pressure Relief ValveFactory Fitted7 bar/95ºC
Tundish
Fluid Flow SequenceMains Water Isolation Valve (Not Supplied)3 bar Pressure Reducing ValveSafety Group (6 bar Expansion Relief Valve c/w Non Return Valve)Expansion VesselDrain Valve (Not Supplied)Stainless Supastor Hot Water Calorifier
40 Product price list 2008
S u p a s t o r S S S o l a r u n v e n t e d c y l i n d e rs
Pressur e Reducing V alve3 bar Pr e-Set
Safety Gr oup c/wNon Return Valve6 bar Relief V alve
Tundish
2 Port V alve For UseWith The IMITThermostatContr olling ThePrimary Flow (Boiler)Water To The Coil
Combined T emperature &Pressure Relief V alveFactory Fitted7 bar / 95oC
Expansion V es sel3kW 230v/50HzImmersion Heater
IMIT CombinedThermostat &Safety Relay
Techn ical Spec i f ication S S S olar ( including K i t)Volume (Nominal) 250 litres 300 litres 500 litres800 litres1000 litres
Supastor Solar HeightDiameter
Weight (Dry kg)
Weight (Normal Full kg)
T&PTapping
T&P Pressure Setting
T&P Temperature SettingExpansion Relief Setting
Electrical Heater Quantity
Electrical Heater Rating
Primary Re-heat Times (82º Supply)
Primary Heat Up Times (F rom Cold)
Max.Primary Pressure (Coil)Primary Flow Rate (Boiler L/min)
Primary Resistance (mbar)
1568
555
43
253
3/4”
7 bar
95ºC
6 bar
1
3 kW
22 mins
27 mins
16 bar
42
324.8
627
33.4
1750
606
55
355
3/4”
7 bar
95ºC
6 bar
1
3 kW
20 mins
25 mins
16 bar
49
987.5
985
52.4
1823
734
75.5
576
3/4”
7 bar
95ºC
6 bar
1
3 kW
31 mins
38 mins
16 bar
67
509.8
1059
56.4
1960
950
122.9
923.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
31 mins
40 mins
16 bar
92
1287.0
1695
90.2
2360
950
136.9
1257.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
40 mins
49 mins
16 bar
92
1287.0
1642
87.4
Primary Continuous Output (mbar)
210 litres
1754
555
46
296
3/4”
7 bar
95ºC
6 bar
1
3 kW
24 mins
30 mins
16 bar
42
354.6
684
36.4
P r i ce and codeCode FC SOLSS
210+KIT
Price £
FC SOLSS250+KIT
FC SOLSS300+KIT
FC SOLSS500+KIT
FC SOLSS800+KIT
FC SOLSS1000+KIT
Primary Coil Rating kWExpansion Vessel 12 L t r 1 2 L t r12 L t r 1 2 L t r 2 4 L t r24 Ltr
Insulation is interlocked polystyrene to allow for inspection of cylinder if r equir ed.
1 2 4 7 . 1 7 1 3 5 0 . 66 1454.17 2 1 2 7 . 9 7 3 8 8 4 . 5 8 4144.60
Fluid Flow SequenceMains W ater Isolation V alve (Not Supplied)3 bar Pres sur e Reducing V alveSafety G roup (6 bar Expansion Relief V alve c/w Non Return V alve)Expansion V esselDrain Valve (Not Supplied)Stainles s Supastor Hot W ater Calorifier
Solar unvented cylinders for potable water installations
2 Port Valve for use with the IMITThermostat controlling the Primary Flow (Boiler)water to the Coil
40 Product price list 2008
S u p a s t o r S S S o l a r u n v e n t e d c y l i n d e rs
Pressur e Reducing V alve3 bar Pr e-Set
Safety Gr oup c/wNon Return V alve6 bar Relief V alve
Tundish
2 Port V alve For UseWith The IMITThermostatContr olling ThePrimary Flow (Boiler)Water To The Coil
Combined T emperature &Pressur e Relief ValveFactory Fitted7 bar / 95oC
Expansion Ves sel3kW 230v/50HzImmersion Heater
IMIT CombinedThermostat &Safety Relay
Techn ical Spec i f ication S S S olar ( including K i t)Volume (Nominal) 250 litres 300 litres 500 litres800 litres1000 litres
Supastor Solar Height
Diameter
Weight (Dry kg)
Weight (Normal Full kg)
T&P TappingT&P Pressure Setting
T&P Temperature Setting
Expansion Relief Setting
Electrical Heater Quantity
Electrical Heater RatingPrimary Re-heat Times (82º Supply)
Primary Heat Up Times (F rom Cold)
Max.Primary Pressure (Coil)
Primary Flow Rate (Boiler L/min)
Primary Resistance (mbar)
1568
555
43
253
3/4”
7 bar
95ºC
6 bar
1
3 kW
22 mins
27 mins
16 bar
42
324.8
627
33.4
1750
606
55
355
3/4”
7 bar
95ºC
6 bar
1
3 kW
20 mins
25 mins
16 bar
49
987.5
985
52.4
1823
734
75.5
576
3/4”
7 bar
95ºC
6 bar
1
3 kW
31 mins
38 mins
16 bar
67
509.8
1059
56.4
1960
950
122.9
923.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
31 mins
40 mins
16 bar
92
1287.0
1695
90.2
2360
950
136.9
1257.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
40 mins
49 mins
16 bar
92
1287.0
1642
87.4
Primary Continuous Output (mbar)
210 litres
1754
555
46
296
3/4”
7 bar
95ºC
6 bar
1
3 kW
24 mins
30 mins
16 bar
42
354.6
684
36.4
P r i ce and codeCode FC SOLSS
210+KIT
Price £
FC SOLSS250+KIT
FC SOLSS300+KIT
FC SOLSS500+KIT
FC SOLSS800+KIT
FC SOLSS1000+KIT
Primary Coil Rating kWExpansion Vessel 12 L t r 1 2 L t r12 L t r 1 2 L t r 2 4 L t r24 Ltr
Insulation is interlocked polystyrene to allow for inspection of cylinder if requir ed.
1 2 4 7 . 1 7 1 3 5 0 . 66 1454.17 2 1 2 7 . 9 7 3 8 8 4 . 5 8 4144.60
Fluid Flow SequenceMains W ater Isolation V alve (Not Supplied)3 bar Pres sur e Reducing V alveSafety G roup (6 bar Expansion Relief V alve c/w Non Return V alve)Expansion V esselDrain V alve (Not Supplied)Stainles sSupastor Hot W ater Calorifier
Solar unvented cylinders for potable water installations
IMIT Combined Thermostat& Safety Relay
Supastor SS Indirect unvented cylindersIndirect unvented cylinders for potable water installations
Safety Group c/wNon Return Valve
P re s s u re ReducingValve Pre-Set
Technical Specification Indirect (including kit)
Insulation is interlocked polystyrene to allow for inspection of cylinder if required.
Supastor SS Indirect unvented cylinders
1750
606
47
1” BSP (M)
412
47
722
1” BSP (F)
802
1” BSP (F)
1225
1532
N/A
Top Centre
1” BSP (M)
976
555
51
1” BSP (M)
419
51
379
1” BSP (F)
518
1” BSP (F)
627
749
N/A
Top Centre
1” BSP (M)
1166
555
51
1” BSP (M)
419
51
379
1” BSP (F)
518
1” BSP (F)
721
939
N/A
Top Centre
1”BSP (M)
1347
555
51
1” BSP (M)
419
51
379
1” BSP (F)
518
1” BSP (F)
845
1119
N/A
Top Centr e
1” BSP (M)
1568
555
51
1” BSP (M)
419
51
554
1” BSP (F)
634
1” BSP (F)
984
1341
N/A
Top Centr e
1” BSP (M)
1758
555
51
1” BSP (M)
419
51
579
1” BSP (F)
659
1” BSP (F)
1108
1531
N/A
Top Centr e
1”BSP (M)
1823
734
52
1” BSP (M)
932
312
832
1” BSP (F)
1142
1” BSP (F)
952
1517
N/A
1517
1”BSP (M)
Height A (mm)
Diameter B (mm)
Cold Water C (mm)
Cold Water Connection
Immersion D (mm)Primary Flow E (mm)
Primary Return F (mm)
Primary Connection
DHW Return G (mm)
Secondary Return Connection (mm)
Thermostat H (mm)T&P Valve J (mm)
Immersion K (mm)
DHW Flow J (mm)
DHW Connection
120 Indirect
150 Indirect
180 Indirect
210 Indirect
250 Indirect
300 Indirect
500 Indirect
800 Indirect
1000 Indirect
1960
950
50
1.1/2 ”BS P (M)
343
338
1038
1” BSP (F)
1238
1” BSP (F)
1103
1603
1103
1603
1.1/2 ”BS P (M)
2360
950
50
1.1/2 ”BS P (M)
343
338
1038
1” BSP (F)
1238
1” BSP (F)
1103
2023
1103
2003
1.1/2 ”BS P (M)
Volume (Nominal)
Techn ica l Spec i f i cat ion Connect ions
120 to 300 litre 800 to 1000 litre500 litre
(M)
(F)
Height A (mm)Diameter B (mm)Cold Water C (mm)Cold Water ConnectionImmersion D (mm)Primary Flow E (mm)Primary Return F (mm)Primary ConnectionDHW Return G (mm)S e c o n d a ry Return Connection (mm)Thermostat H (mm)T&P Valve J (mm)Immersion K (mm)DHW Flow JDHW Connection
97655551
1” BSP (M)41951379
1” BSP (F)518
1” BSP (F)627749N/A
Top Centre1” BSP (M
116755551
1” BSP (M)41951379
1” BSP (F)518
1” BSP (F)721939N/A
Top Centre1” BSP (M
134755551
1” BSP (M)41951379
1” BSP (F)518
1” BSP (F)845
1119N/A
Top Centre1” BSP (M
156955551
1” BSP (M)41951554
1” BSP (F)634
1” BSP (F)9841341N/A
Top Centre1” BSP (M
175955551
1” BSP (M)41951579
1” BSP (F)659
1” BSP (F)11081531N/A
Top Centre1” BSP (M)
175060647
1” BSP (M)41247722
1” BSP (F)802
1” BSP (F)12251532N/A
Top Centre1” BSP (M
182373452
1” BSP (M)932312832
1” BSP (F)1142
1” BSP (F)9521517N/A1517
1” BSP (M
196095050
1 .1 / 2” BSP (M)3433381038
1” BSP (F)1238
11/2” BSP (F)1103160311031603
1 .1 / 2” BSP (M)
2360950338
1 .1 / 2” BSP (M)3433381038
1” BSP (F)1238
11/2” BSP (F)1103202311032003
1 .1 / 2” BSP (M)
120 litresIndirect
150 litresIndirect
180 litresIndirect
1000 litresIndirect
800 litresIndirect
500 litresIndirect
300 litresIndirect
250 litresIndirect
210 litresIndirect
Volume (Nominal)
Technical Specification Indirect (including kit)
800 to 1000 litre500 litre120 to 300 litre
KFG
CD
G
H
J
A
B
CE
FH
GJ
A
B
D
A
B
JG
HF
E C D
40 Product price list 2008
S u p a s t o r S S S o l a r u n v e n t e d c y l i n d e rs
Pressur e Reducing V alve3 bar Pr e-Set
Safety Gr oup c/wNon Return V alve6 bar Relief V alve
Tundish
2 Port V alve For UseWith The IMITThermostatContr olling ThePrimary Flow (Boiler)Water To The Coil
Combined T emperature &Pressur e Relief ValveFactory Fitted7 bar / 95oC
Expansion Ves sel3kW 230v/50HzImmersion Heater
IMIT CombinedThermostat &Safety Relay
Techn ical Spec i f ication S S S olar ( including K i t)Volume (Nominal) 250 litres 300 litres 500 litres800 litres1000 litres
Supastor Solar Height
Diameter
Weight (Dry kg)
Weight (Normal Full kg)
T&P Tapping
T&P Pressure Setting
T&P Temperature Setting
Expansion Relief Setting
Electrical Heater Quantity
Electrical Heater Rating
Primary Re-heat Times (82º Supply)
Primary Heat Up Times (F rom Cold)
Max.Primary Pressure (Coil)
Primary Flow Rate (Boiler L/min)
Primary Resistance (mbar)
1568
555
43
253
3/4”
7 bar
95ºC
6 bar
1
3 kW
22 mins
27 mins
16 bar
42
324.8
627
33.4
1750
606
55
355
3/4”
7 bar
95ºC
6 bar
1
3 kW
20 mins
25 mins
16 bar
49
987.5
985
52.4
1823
734
75.5
576
3/4”
7 bar
95ºC
6 bar
1
3 kW
31 mins
38 mins
16 bar
67
509.8
1059
56.4
1960
950
122.9
923.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
31 mins
40 mins
16 bar
92
1287.0
1695
90.2
2360
950
136.9
1257.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
40 mins
49 mins
16 bar
92
1287.0
1642
87.4
Primary Continuous Output (mbar)
210 litres
1754
555
46
296
3/4”
7 bar
95ºC
6 bar
1
3 kW
24 mins
30 mins
16 bar
42
354.6
684
36.4
P r i ce and codeCode FC SOLSS
210+KIT
Price £
FC SOLSS250+KIT
FC SOLSS300+KIT
FC SOLSS500+KIT
FC SOLSS800+KIT
FC SOLSS1000+KIT
Primary Coil Rating kWExpansion Vessel 12 L t r 1 2 L t r12 L t r 1 2 L t r 2 4 L t r24 Ltr
Insulation is interlocked polystyrene to allow for inspection of cylinder if requir ed.
1 2 4 7 . 1 7 1 3 5 0 . 66 1454.17 2 1 2 7 . 9 7 3 8 8 4 . 5 8 4144.60
Fluid Flow SequenceMains W ater Isolation V alve (Not Supplied)3 bar Pres sur e Reducing V alveSafety G roup (6 bar Expansion Relief V alve c/w Non Return V alve)Expansion V esselDrain V alve (Not Supplied)Stainles sSupastor Hot W ater Calorifier
Solar unvented cylinders for potable water installations
Expansion Vessel
2 off 3 kW 230v/50HzImmersion Heater
Combined Temperature& Pressure Relief ValveFactory Fitted 7 bar/95ºC
Tundish
Safety Group c/wNon Return Valve6 bar Relief
P re s s u re ReducingValve Pre-Set
Supastor SS Solar unvented cylindersSolar unvented cylinders for potable water installations
40 Product price list 2008
S u p a s t o r S S S o l a r u n v e n t e d c y l i n d e rs
Pressur e Reducing V alve3 bar Pr e-Set
Safety Gr oup c/wNon Return Valve6 bar Relief V alve
Tundish
2 Port V alve For UseWith The IMITThermostatContr olling ThePrimary Flow (Boiler)Water To The Coil
Combined T emperature &Pressure Relief V alveFactory Fitted7 bar / 95oC
Expansion V es sel3kW 230v/50HzImmersion Heater
IMIT CombinedThermostat &Safety Relay
Techn ical Spec i f ication S S S olar ( including K i t)Volume (Nominal) 250 litres 300 litres 500 litres800 litres1000 litres
Supastor Solar HeightDiameter
Weight (Dry kg)
Weight (Normal Full kg)
T&PTapping
T&P Pressure Setting
T&P Temperature SettingExpansion Relief Setting
Electrical Heater Quantity
Electrical Heater Rating
Primary Re-heat Times (82º Supply)
Primary Heat Up Times (F rom Cold)
Max.Primary Pressure (Coil)Primary Flow Rate (Boiler L/min)
Primary Resistance (mbar)
1568
555
43
253
3/4”
7 bar
95ºC
6 bar
1
3 kW
22 mins
27 mins
16 bar
42
324.8
627
33.4
1750
606
55
355
3/4”
7 bar
95ºC
6 bar
1
3 kW
20 mins
25 mins
16 bar
49
987.5
985
52.4
1823
734
75.5
576
3/4”
7 bar
95ºC
6 bar
1
3 kW
31 mins
38 mins
16 bar
67
509.8
1059
56.4
1960
950
122.9
923.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
31 mins
40 mins
16 bar
92
1287.0
1695
90.2
2360
950
136.9
1257.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
40 mins
49 mins
16 bar
92
1287.0
1642
87.4
Primary Continuous Output (mbar)
210 litres
1754
555
46
296
3/4”
7 bar
95ºC
6 bar
1
3 kW
24 mins
30 mins
16 bar
42
354.6
684
36.4
P r i ce and codeCode FC SOLSS
210+KIT
Price £
FC SOLSS250+KIT
FC SOLSS300+KIT
FC SOLSS500+KIT
FC SOLSS800+KIT
FC SOLSS1000+KIT
Primary Coil Rating kWExpansion Vessel 12 L t r 1 2 L t r12 L t r 1 2 L t r 2 4 L t r24 Ltr
Insulation is interlocked polystyrene to allow for inspection of cylinder if r equir ed.
1 2 4 7 . 1 7 1 3 5 0 . 66 1454.17 2 1 2 7 . 9 7 3 8 8 4 . 5 8 4144.60
Fluid Flow SequenceMains W ater Isolation V alve (Not Supplied)3 bar Pres sur e Reducing V alveSafety G roup (6 bar Expansion Relief V alve c/w Non Return V alve)Expansion V esselDrain Valve (Not Supplied)Stainles s Supastor Hot W ater Calorifier
Solar unvented cylinders for potable water installations
40 Product price list 2008
S u p a s t o r S S S o l a r u n v e n t e d c y l i n d e rs
Pressur e Reducing V alve3 bar Pr e-Set
Safety Gr oup c/wNon Return V alve6 bar Relief V alve
Tundish
2 Port V alve For UseWith The IMITThermostatContr olling ThePrimary Flow (Boiler)Water To The Coil
Combined T emperature &Pressur e Relief ValveFactory Fitted7 bar / 95oC
Expansion Ves sel3kW 230v/50HzImmersion Heater
IMIT CombinedThermostat &Safety Relay
Techn ical Spec i f ication S S S olar ( including K i t)Volume (Nominal) 250 litres 300 litres 500 litres800 litres1000 litres
Supastor Solar Height
Diameter
Weight (Dry kg)
Weight (Normal Full kg)
T&P Tapping
T&P Pressure Setting
T&P Temperature Setting
Expansion Relief Setting
Electrical Heater Quantity
Electrical Heater Rating
Primary Re-heat Times (82º Supply)
Primary Heat Up Times (F rom Cold)
Max.Primary Pressure (Coil)
Primary Flow Rate (Boiler L/min)
Primary Resistance (mbar)
1568
555
43
253
3/4”
7 bar
95ºC
6 bar
1
3 kW
22 mins
27 mins
16 bar
42
324.8
627
33.4
1750
606
55
355
3/4”
7 bar
95ºC
6 bar
1
3 kW
20 mins
25 mins
16 bar
49
987.5
985
52.4
1823
734
75.5
576
3/4”
7 bar
95ºC
6 bar
1
3 kW
31 mins
38 mins
16 bar
67
509.8
1059
56.4
1960
950
122.9
923.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
31 mins
40 mins
16 bar
92
1287.0
1695
90.2
2360
950
136.9
1257.4
3/4”
7 bar
95ºC
6 bar
2
6 kW
40 mins
49 mins
16 bar
92
1287.0
1642
87.4
Primary Continuous Output (mbar)
210 litres
1754
555
46
296
3/4”
7 bar
95ºC
6 bar
1
3 kW
24 mins
30 mins
16 bar
42
354.6
684
36.4
P r i ce and codeCode FC SOLSS
210+KIT
Price £
FC SOLSS250+KIT
FC SOLSS300+KIT
FC SOLSS500+KIT
FC SOLSS800+KIT
FC SOLSS1000+KIT
Primary Coil Rating kWExpansion Vessel 12 L t r 1 2 L t r12 L t r 1 2 L t r 2 4 L t r24 Ltr
Insulation is interlocked polystyrene to allow for inspection of cylinder if requir ed.
1 2 4 7 . 1 7 1 3 5 0 . 66 1454.17 2 1 2 7 . 9 7 3 8 8 4 . 5 8 4144.60
Fluid Flow SequenceMains W ater Isolation V alve (Not Supplied)3 bar Pres sur e Reducing V alveSafety G roup (6 bar Expansion Relief V alve c/w Non Return V alve)Expansion V esselDrain V alve (Not Supplied)Stainles sSupastor Hot W ater Calorifier
Solar unvented cylinders for potable water installations
IMIT Combined Thermostat& Safety Relay
2 Port Valve for use with the IMITThermostat controlling the Primary Flow (Boiler)water to the Coil
Fluid Flow SequenceMains Water Isolation Valve (Not Supplied)3 bar Pressure Reducing ValveSafety Group (6 bar Expansion Relief Valve c/w Non Return Valve)Expansion VesselDrain Valve (Not Supplied)Stainless Supastor Hot Water Calorifier
Supastor Solar HeightDiameterWeight (Dry kg)Weight (Normal Full kg)T&P Tapping T&P Pressure SettingT&P Temperature SettingExpansion Relief SettingElectrical Heater QuantityElectrical Heater RatingPrimary Re-heat Times (82º Supply)Primary Heat Up Times (From Cold)Max. Primary Pressure (Coil)Primary Flow Rate (Boiler L/min)Primary Resistance (mbar)Primary Continuous Output (mbar)Primary Coil Rating kWExpansion Vessel
1754555462963/4”
7 bar95º
6 bar1
3 kW24 mins30 mins16 bar
42354.668436.4
12 Ltr
1750606553553/4”
7 bar95º
6 bar1
3 kW20 mins25 mins16 bar
49987.598552.4
12 Ltr
182373475.55763/4”
7 bar95º
6 bar1
3 kW31 mins38 mins16 bar
67509.8105956.4
12 Ltr
1960950
122.9923.43/4”
7 bar95º
6 bar2
3 kW31 mins40 mins16 bar
921287.0169590.2
24 Ltr
2360950
136.91257.4
3/4”7 bar95º
6 bar2
3 kW40 mins49 mins16 bar
921287.0164187.4
24 Ltr
210 litres 250 litres 300 litres 1000 litres800 litres500 litresVolume (Nominal)
Technical Specification SS Solar (including kit)
1568555432533/4”
7 bar95º
6 bar1
3 kW22 mins27 mins16 bar
42324.862733.4
12 Ltr
Insulation is interlocked polystyrene to allow for inspectionof cylinder if required.
Property TypeBedsit1/2 beds with 1 bath/shower3 beds with 1 bath/shower4 beds with 1 bath/shower2/3 beds with 2 baths/showers4/5 beds with 2 baths/showersSports club, Restaurant etc.Hotels, Schools etc.
Indirect Size
120 150 or 180180 or 210210210 or 250300 or 500800 or 1000
•In areas with high concentration ofChlorine (200 ppm or above) additionalprotection of the cylinder is requiredwith an electrical anode.
This is an optional extra and is notreflected in the pricing.
VesselsIndirect vessels can be suppliedwithout kits asa storage vessel
Selection Guide
Supastor SS Solar unvented cylinders
Height A (mm)Diameter B (mm)Cold Water C (mm)Cold Water ConnectionImmersion D (mm)Primary Flow E (mm)Primary Return F (mm)Primary ConnectionDHW Return G (mm)S e c o n d a ry Return Connection (mm)Thermostat H (mm)T&P Valve J (mm)Immersion K (mm)DHW Flow J (mm)DHW ConnectionSecondary Return L (mm)Secondary Flow J (mm)Secondary ConnectionThermostat Primary Coil Pocket (mm)
156855551
1” BSP (M)88151379
1” BSP (F)634
1” BSP (M)12161341N/A
Top Centre1” BSP (M
10981341
1” BSP (F)289
175455551
1” BSP (M)83451379
1” BSP (F)659
1” BSP (M)11081531N/A
Top Centre1” BSP (M)
12881531
1” BSP (F)289
182373452
1” BSP (M)932312832
1” BSP (F)952
1” BSP (M)9521517N/A1517
1” BSP (M10771437
1” BSP (F)558
1960950338
1 .1 / 2” BSP (M)3433381038
1” BSP (F)1238
1” BSP (M)1103160311031603
1 .1 / 2” BSP (M)1 1 9 31 6 0 3
1” BSP (F)1103
2360950338
1 .1 / 2” BSP (M)3433381038
1” BSP (F)1238
1” BSP (M)1103202311032003
1 .1 / 2” BSP (M)1 4 4 31 8 5 3
1” BSP (F)1103
1000 litresSolar
800 litresSolar
500 litresSolar
300 litresSolar
250 litresSolar
210 litresSolarVolume (Nominal)
Technical Specification Indirect (including kit)
175060647
1” BSP (M)1117147372
1” BSP (F)774
1” BSP (M)12251532N/A
Top Centre1” BSP(M)
1017774
1” BSP (F)282
120 to 300 litre 500 litre 800 to 1000 litre
B B
B
A
D
C
J
AA
C C D
D
E EF F
HHL
L
JJ
H
F
G
GG
LK