SUN StorEdge Library Installation & Operating Manual(Quantum OEM)

23
SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim([email protected]) Storage Business Dept. 1 Team LOIT Co., Ltd

description

SUN StorEdge Library Installation & Operating Manual(Quantum OEM). Dae suk, Kim([email protected]) Storage Business Dept. 1 Team LOIT Co., Ltd. OEM of Quantum M1500 Supported Drive Type SCSI-LVD : SDLT320, LTO Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 - PowerPoint PPT Presentation

Transcript of SUN StorEdge Library Installation & Operating Manual(Quantum OEM)

Page 1: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

SUN StorEdge Library Installation & Operating Manual(Quantum OEM)

Dae suk, Kim([email protected])Storage Business Dept. 1 Team

LOIT Co., Ltd

Page 2: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

SUN StorEdge L25 Tape Library OEM of Quantum M1500

Supported Drive Type SCSI-LVD : SDLT320, LTO

Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal

Bridge(FC420) or External Bridge

Not Support Mixed Drive Max # of Cartridge Slot

21 DLT or 25 LTO slots Max Capacity : 5 TB Max # of Drives : 2 (All

Type) Barcode Label : Included Mix & Match L25 with L100

Libraries Up to 14 Drive & 175 slots

when scaled to seven modules

4u rack height Hot swappable tape drives

& power supplies Standard redundant power

supplies 250,000 hours MTBF

Front View

Page 3: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

SUN StorEdge L100 Tape Library OEM of Quantum M2500

Supported Drive Type SCSI-LVD : SDLT320, LTO

Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal

Bridge(FC420) or External Bridge

Not Support Mixed Drive Max # of Cartridge Slot

84 DLT or 100 LTO slots Max Capacity : 20 TB Max # of Drives : 6 (All

Type) Barcode Label : Included Mix & Match L25 with L100

Libraries Standalone & Rackmount

Configurations Hot swappable tape drives

& power supplies Standard redundant power

supplies 250,000 hours MTBF

Front View

Page 4: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Hardware 구성도

Terminator

X6758A(Ultra3 HBA)

Page 5: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Library Setup Order 1. Host 에 Scsi Cable 연결 & Library Power On (11 번 Slide 참

조 ) 2. Library Inventory 종료 후 Media Import (11 번 Slide 참조 ) 3. OS 상에서의 St Driver & Ultra3 Patch 확인 , Patch(6 번 Slide

참조 )

4. Tape Device 생성 가 . OK mode : OK> boot –r 나 . MultiUser Mode : # reboot -- -r or #drvconfig;tapes;

(Online Rebuild) 5. OS 상에서의 Device 생성 확인 가 . #luxadm inq /dev/rmt/ 테잎순서 or # /dev/rmt/ 밑에 device 생성되었는지 확인 나 . Netbackup or NetWorker 상에서 changer & tape 확인

#sgscan –v changer;sgscan –v tape (Netbackup Utility)

#inquire (Networker Utility)

6. Robot Test

가 . #/usr/openv/volmgr/bin/robtest 로 미디어 제어확인

ex) init , test_ready etc …

Page 6: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

ST Driver Patch Required Scsi Type 에 맞는 HBA Card 장착

Ultra3 SCSI(LVD) 160m/s : X6758A Ultra2 SCSI(LVD) 80m/s : X2222A Ultra Differential(HVD) 40m/s : X6541A Ultra Differential Fast/Wide(HVD) 40m/s : X6749A(EOL)

Device Server 쪽에 current version st.conf 등록 Version 별 Patch Name

Solaris 2.6 : 105847 Solaris 7 : 107460 Solaris 8 : 108725 Solaris 9 : 13277

LVD tape drive 는 Solaris 7, 이하 버전 지원못함 Device Server 쪽에 Ultra3 patch(Ultra 3 Scsi 일 경우 )

SUNWqus.tar.Z [66K] SUNWqusx.tar.Z [68K] SUNWqusu.tar.z [3K] SUNWqusux.tar.Z [4K]

Page 7: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Performance Tunning HBA 의 최대 속도와 Library 의 속도 확인

X6758A(Ultra3 SCSI) 의 경우

HBA 속도 : 160m/s(Dual Port), 한 개 Port 는 Maximun 80m/s 지원

LTO2 Drive( 초당 30m/s) 지원 L8 Library 의 경우 Robot 과 Drive 가 같은 Port 를 사용하므로

X6758 한 개 Port 만으로도 드라이브 속도를 충분히 소화할수 있음

Drive 가 여러 개인 경우 / Robot Scsi Port 가 분리된 경우 (L25/L100/L180)

HBA 의 한 개 Port 의 Maximun Speed 와 드라이브 속도 체크 Ex) Drive 가 3 개인 경우 Library 쪽 port 는 Maximum 4ea(Robot 1ea / Drive

3ea) Robot 3ea 를 Jumping 할 경우 90m/s 를 지원해야 함 따라서 X6758 의 경우 80m/s 밖에 지원이 안되므로 나머지

port 를 사용하여 Library 쪽에서두개의 Line 을 사용하는 것이 바람직함

(Robot+Drive1ea = 1 개 channel / Drvie2ea = 1 개 channel)

Robot 에 연결된 Scsi Fail 시 Drive 작동이 전혀 불가하므로 가능하면 Redundancy 차원의 Scsi Cable 을 분리하여 잉여 드라이브를 사용 권장

Page 8: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Connect Library to the HOST Cabling Diagram

Single SCSI BUS HBA Card 의 속도가 Drive

2ea 를 지원하고 한 개 Port 만 사용시

Two SCSI BUS 분리된 HBA Card or Port 를

사용하여 속도 & Redundancy 고려

Three SCSI BUS Drive, Robot 을 전부 분리 ,

HBA Card or Port 를 사용하여 속도 & Redundancy 고려

Page 9: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

L100 Recommended Cabling Cabling Diagram

X6758A 3개

Page 10: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Hardware Installing Order Drive Installing Tape Labeling

Unpacking L25 Base / Drive / Tape

HVD / LVD Type 고려하여 Drive installing(Max 2ea)

Tape Barcode Labeling 쓰기방지탭 조정

Left : Enabled Right : Write-Protected

필요시 Management Card 추가 장착

Write Protect Switch Setup

Page 11: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Hardware Installing Order Remove magazine & Inserting Tapes

L25 Power Off 시 : 펜을 이용하여 release button 을 누른후에 Magazine 분리

Power On 시 : LCD Pannel Key 조작을 이용하여 Main-Mags-Release 사용 Labeling 된 Tape 을 Magazine 에 삽입한다 ( 상하주의 , 강제삽입 금지 ) Tape 분리시 : Cartridge retaining latch 를 누른 상태에서 분리 Cleaning Tape : L25 Magazine 빼낸 후 안쪽의 Fixed Slot 에 직접 삽입

Page 12: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Powering Up the Library Connect L25 Library to AC Power

Library run Post-On-Self-Test(POST)

Power ON Initializing 을 통해 자동

inventory 및 Self Test실행

완료시 GUI 에 Drive / Slot 별 Media Status 출력

각 GUI Screen 의 하단에 5개 Button label 로 조작

Page 13: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Disabling Unused Drive Bays Using the GUI Buttons

사용하지 않는 Drive Bay Setup Main GUI -> Press Menu -> Press

Config Unused drive bay 에 highlight

될때까지 up, down key 로 조작후 Press Select

Press Down Button Until Disabled Setup 완료후 main screen 으로

돌아가지 않으면 NVRM 에 저장되지 않는다 Setting 이 제대로 인식되기 위해 반드시

Library 를 Reboot 한다

Page 14: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Library Features Front Panel Graphical User Interface(GUI)

라이브러리 상태 정보 , 라이브러리 메뉴를 액세스 할수있게 해줌

Library Setting 값의 View & Change, daemonstration programs 의 구동 , diagnostic tests

Magazine door buttons Mags option 을 사용하여 Unlocked

magazine 을 열때 , Power-Off & magazine Open 시 사용

Light Emitting Diode(LED) Green LED : 호스트 채널로부터 액세스

가능하도록 Full Operational & Ready 상태

Green LED Flash : Ready 상태에서 NOT Ready 상태로 변환되는중

Power-On-Self-Test 시 Magazine Release 상태일 경우 특정 menu Item access 시

Red LED : Library Error

Page 15: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Library Features

Internal Layout

Back Pannel

Page 16: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

GUI Icon Status No tape

present

Tape Loading

Tape Unloading

Tape Unloaded

Tape Idle

Tape Rewinding

Location Data

Reading Data

Writing Data

Power On

Drive Fault

Tape Is Write-Protected

Drive Need Cleaning

Slot Empty

Solt Occupied

Slot Occupied – no Label

or Bad barcode

Page 17: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Library & Drive & Inventory Info. Main GUI -> Press

Quick View -> Press Library or Drive or Inventory

Modelaud / Code Revision, Scsi ID 기타 정보 확인

Library 가 L100이상이거나 Stack Link인 경우는 Level button을 이용하여 각단계별 Inventory 확인

Page 18: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Release Magazine & Drive Power

Main GUI -> Press Quick View -> Drv Pwr

Power-On, Off 시킬 Drive Select

해당 Drive highlishted 되면 Up, Down button 으로 현재 Setting 변경

Tape Drive Hot-Swapping에 주로 사용

Magazine 을 분리하기 위해 Library On 상태에서 실행

Main GUI -> Press Mags -> Release Magazine 창에서

Left / Right / Both 중 Open시킬 Magazine 선택 , select

전면 Magazine door button누른 후 Magazine 분리 , 작업

완료후 Re-Lock

Page 19: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Moving Tape Cartridges Main GUI -> Press

Menu -> Press Move -> Move Cartridge FROM

Up, Down 키로 이동시킬 미디어를 선택한후 Select Key Press

->Move Cartridge TO 에서 이동시킬 Slot or Drive 에 커서 위치시키고 Select

->Confirm Move Cartridge 로 최종 확인

완료시 : Moving Cartridge…. Please Wait 출력후 Move Cartridge FROM GUI Displayed again

Press Back button

Press Main button

Page 20: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Scsi History & Library Statistics

Main GUI -> Press Menu-> Press Service -> Press Stats

-> Library or Drive or Scsi History 중 택 1

날짜 또는 시간별 SCSI Bus Command history 상태 / Library, Drive Detail Statistics 확인

Page 21: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Changing the Library Configuration Changing the Baud Rate Setting

Serial Diagnostics port 접속을 위한 baud rate Control

Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select baud rate -> Press Select -> up & Down, select desired Baud Rate

Setting the Time & Date

Library Time & date 설정

Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Time or Date -> Press Select -> up & Down, select correct date, time

Changing the AUTO-Clean Setting

Default Setting -> Disabled, Hardware 적으로 적정 시점에 Cleaning 할수 있도록 Setup( 권장 ) / Backup S/W 의 clean setup 사용시보다 관리 용이

Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Auto-Clean -> Press Select -> up & Down, select Enabled

Page 22: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Performing Maintenance Operations

수동 Cleaning 시 사용 Main GUI -> Press Menu ->

Press Service -> Press Maint -> Press Clean -> DisPlayed “Select Cleaning Cartridge screen” -> 클리닝 카트리지 선택 -> DisPlayed “Select Tape Drvie” -> 클리닝할 드라이브 선택

Cleaning a Tape Drive Adjusting the Contrast

Main GUI -> Press Menu -> Press Service -> Press Maint -> Press Contrast

원하는 Contrast 까지 Increase or Decrease Button Press

Page 23: SUN StorEdge Library Installation & Operating  Manual(Quantum OEM)

2004 Loit Co., Ltd Storage Business Dept. 1 Team

Related Documentation

Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library Installation Guide

- Explains how to install a stand-alone Sun StorEdge L25 Tape Library or Sun StorEdge L100 Tape Library

Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User's Guide

- Describes the Sun StorEdge L25 Tape Library and the Sun StorEdge L100 Tape Library and their use.

H/W 장애시 LCD 에 출력되는 Fault System Code(FSC) Dictionary 참조 , TroubleShooting

Thank You!