Summit x670
-
Upload
muk -
Category
Technology
-
view
142 -
download
0
Transcript of Summit x670
2
Modular
Extreme Networks® Product Portfolio
Fixed10/100M 1G 10G 40G 1/10/40G 10/40/100G
Summit X250e
Summit X150
E4G 200/400Only 400 model stacks
Summit X480
Summit X450e
Summit X450a
Summit X460
Summit X350
Summit X650
BlackDiamond 8800 with 8500-Series
Modules
BlackDiamond X Series
SummitStack™
WirelessSingle-Radio AP
Adaptive AP Wallplate AP
Controller w/ AP*
Network Management
Ridgeline™
Motorola ADSP
EAS
ReachNXT™
Summit® WM
BlackDiamond 8800 with C-Series
Modules
BlackDiamond® 8800 with 8900-Series
Modules
8900-40G6X-Xm
VIM3-40G4X
Summit X440
Summit X670
VIM4-40G4X
Новый коммутатор X670
Тенденции– Консолидация и конвергенция
– Необходимость в интерфейсах
10 GbE и выше
Продукты 40 GbE Summit – 48 x 10 GbE + 4 x 40 GbE
(или 64 x 10 GbE) в форм-факторе 1 RU (Summit X670V)
– 4 x 40 GbE модуль для Summit® X650 and X480
– Высокоскоростное стекирование 160 GbE или 320 GbEна большие расстояния через интерфейсы 40 GbE (Summit X670V/X650)
• 48 x 10 GbE + 4 x 40 GbE (or 64 x10 GbE)
• Поддержка MLAG, Selective QinQ
• Технология MPLS (H-VPLS)
• Низкое энергопотребление, отказоустойчивые блоки питания
Summit X670V
• 4 x 40 GbE модуль для Summit X670V, X650 и X480
Защита инвестиций
3
Серия Summit X670
Summit® X670V-48x– 48 портов GbE/10 GbE
– Один модуль расширения для VIM4-40G-4X:
• 4 порта 40 GbE
• 16 портов 10 GbE с разветвителями
• 64 порта 10 GbE в коммутаторе
• SummitStack™-V320 используя 4 порта
40 GbE
– Стеккирование SummitStack-V используя
два порта 10 GbE
Summit X670-48x– 48 портов 1 GbE/10 GbE
– Стеккирование SummitStack-V используя
два порта 10 GbE ports
4
5
48-port Dual Speed 1 GbE/10 GbE (SFP+) passive copper
2+1 Fan TrayAC/DC Power
SupplyOptional Redundant AC/DC Power Supply
Motion Sensor
Expansion Slot with Optional 4-port 40 GbE Module (QSFP+)
Summit® X670V Switch Design
6
Модель Summit X670V-48xШирокая функциональность и
масштабируемость– 128K L2 MAC адресов (в 4 раза больше,
чем Summit® X650)– 16K маршрутов IPv4
Data Center Bridging (DCB)– Priority Flow Control (PFC)– Enhanced Transmission Selection (ETS) – Data Center Bridging Exchange Protocol
(DCBX)
Cut-through, задержка менее1 µsec
Настраиваемые порты 40 GbE– Каждый порт 40 GbE может быть настроен
как 4 порта 10 GbE
Передняя панель: 48-port 10 GbE (SFP+)
+
Задняя панель: 4-port 40 GbE option (QSFP+)
40 GbE Optics Адаптер 40 GbE to 4 x 10 GbE 40 GbE Passive Copper до 3х метров
Модули QSFP+
40 GbE Active Fiber до 100 метров
48-port Dual Speed 1 GbE/10 GbE (SFP+) passive copper
2+1 Fan TrayAC/DC Power
SupplyOptional Redundant AC/DC Power Supply
Motion Sensor
Summit® X670 Switch Design
7
8
Модель Summit X670-48x
Широкая функциональность и масштабируемость
– 128K L2 MAC адресов (в 4 раза больше, чем Summit® X650)
– 16K маршрутов IPv4
Data Center Bridging (DCB)
– Priority Flow Control (PFC)
– Enhanced Transmission Selection (ETS)
– Data Center Bridging Exchange Protocol (DCBX)
Cut-through, задержка менее1 µsec
Передняя панель: 48-port 10 GbE (SFP+)
+
Задняя панель: Нет порта данных
PHY-less Design (функции уже интегрированы в ASIC)– Более низкая задержка и энергопотребление
– Не поддерживает модули LRM или выше, интерфейсы SFP+ passive copper до 5-ти метров
– Улучшенное ценообразование
Summit X670 Motion Sensor
В коммутаторы серии Summit® X670 установлены сенсоры движения
– Обнаружение движущихся объектов для обеспечения безопасности
– Возможность выключения LEDs когда нет движения
– Логгирование движений EMS (Event Management System)
– Генерация трапов SNMP, сообщений syslog, и т.д.
Motion Sensor
9
Summit® X670V/X670 Реверсивный поток воздуха
Коммутатор поставляется с двумя вариантами блоков вентиляторов
• Модель Front-to-back airflow (FB)• Стандартная инсталляция, порты10 GbE впереди шкафа
• Модель Back-to-front airflow (BF) • Установка коммутатора с задней стороны шкафа
Поток воздуха от PSU должен совпадать по направлению с блоками вентиляторов
• 450W PSU только FB airflow• 450W PSUs те же, что и Summit® X480 AC/DC PSUs
• 550W PSUs имеют две опции: front-to-back и back-to-front airflow • 550W AC FB и BF airflow
• 550W DC FB и BF airflow
Направление воздуха запасных блоков питания должно совпадать с уже установленными блоками питания
!!! Одновременная поддержка блоков питания AC и DC в одном коммутаторе
10
Summit X670V and X650 model onlyWith 40 GbE Module (VIM4-40G4X)
– 4-port SummitStack™-V320
– 2-port SummitStack™-V160
– 2-port SummitStack-V80
– Compatible with Summit X460/X480 with SummitStack-V80 modules
Summit X670 and X670V models– 2-port SummitStack-V (only 47,48 ports)
– Compatible with Summit X650/X480/X450e/X450a/X460
Summit X670V
Summit X650
Summit X460/480
Summit X460/480
Summit X670
Up
to 8 u
nits
Summit® X670V
Summit X650
Summit X650
Summit X480
Summit X670V
Up
to 8 u
nits
Summit switch X670V / X650 X480 X460
SummitStack-V320 Yes Yes No
SummitStack-V160 Yes Yes No
SummitStack-V80 Yes (use V160) Yes Yes
SummitStack-V Yes Yes Yes
SummitStack Yes Yes Yes
Опции стекирования коммутаторов
11
12
Summit X670 Series Optics SupportSFP/SFP+ Transceivers Summit® X670-48x Summit X670V-48x
48 x SFP+ ports 48 x SFP+ ports
1000BASE-SX SFP Yes Yes
1000BASE-LX SFP Yes Yes
1000BASE-ZX SFP Yes Yes
1000BASE-LX100 SFP Yes Yes
10/100/1000BASE-T SFP Yes Yes, using reference sell
1000BX-D/U SFP Yes Yes
10GBASE-SR SFP+ Yes Yes
10GBASE-LR SFP+ Yes Yes
10GBASE-LRM SFP+ (NEW) No Yes
10GBASE-ER SFP+ Yes Yes
10GBASE-CR SFP+ 1m – 10m Up to 5 meters Up to 10 meters
QSFP+ Transceivers Summit X670-48x Summit X670V-48x
N/A 4 x QSFP+ ports
QSFP+ passive copper cable Yes
QSFP+ active fiber cable Yes
40GBASE-SR4 QSFP+ optic Yes
Summit Plugin 40G Ethernet
• VIM4-40G4X (X670V)– QSFP+ connector
– 4 x 40G ports
– Each port can be configured into 4x10G
– S3, S4 used for stacking SummitStack – V160
– S1,S3 and S2,S4 used for stacking SummitStack – V320
– LED 1 is blue when 40G
– LED 1-4 is green when 10G
13
14
Summit X670 Software License
Feature Packs can be applied to both license levels
Advanced Edge (Base)
Core License (Option)
Includes all L2/L3 switching with STP, LAG, M-LAG, XNV™, CLEAR-Flow, and RIPv1/v2/ng for IPv4/v6 OFPFv2/v3 edge mode, VRRP, PBR, PIM-SM-edge-mode, EAPS-full-mode, etc.
BGP4/BGP4+, IS-IS for IPv4/v6, OSPFv2/v3-full, MSDP, PIM-DM/SM/SSM, etc.
Direct Attach™Feature Pack
(Direct Attach & VEPA)
MPLS Feature Pack
(MPLS, VPLS, H-VPLS)
Summit X670V and X650 ComparisonSummit® X670 offers equal or greater scalability than Summit X650
Feature Summit X670V Summit X650 Notes
Max Ports 48 x 10 GbE + 4 x 40GbE 24 x 10 GbE + 8 x 10GbE 2x Speed/Density
10G port type SFP+ SFP+ or 10GBASE-TSummit X650 for 10GbT opportunity
StackingSummitStack™-V320 V160,V80,V
SummitStack-V320, V160,V80,V, 256, -512
Virtual Chassis
L2 MAC 128K 32K 4x Scalability
L3 Route 16K LPM 12K LPM Equivalent
QoS Egress 8 queues per port Egress 8 queues per port Equivalent
ACLs 2K ingress, 1K egress 2K ingress, 512 egress 2 x Scalability
BW ControlIngress policing and egress shaping
Ingress policing and egress shaping
Bidirectional w/o loopback
PowerDual, hot-swappable AC/DC, mixed support
Dual, hot-swappable AC/DCMore flexible with AC/DC mixed support
FAN/Cooling2+1 fan tray, front-to-back and back-to-front
Removable fan tray, front-to-back
Higher availability and ideal airflow
Operating System
ExtremeXOS® ExtremeXOS Consistent Modular OS
15
The Extreme Networks Solution
M-LAG(Multiswitch Link Aggregation)
Масштабируемое, надежное и производительное ядро ЦОД
Модульная ОС
XNV™
DCBX
M-LAG
Direct Attach™
OpenFlow
40GE
..позволяет агрегировать два или более физических канала на двух коммутаторах в один логический. В качестве подключаемого сетевого устройства может быть сервер или коммутатор, порты которого настроена как обычный LAG (Link Aggregation Group) или teaming сетевых карт.
High-density
IDM
16
Увеличение пропускнойспособности 2х
• MLAG - Multiswitch LAG
• Объединение двух коммутаторов в виртуальный коммутатор с синхронизацией таблиц коммутации
• Выглядит для других коммутаторов одним коммутатором, поэтому возможно использовать группу каналов (LAG), которая работает с обоими коммутаторами одновременно
Меньше конфигурирования и увеличение пропускной способности!
17
The Extreme Networks Solution
DCBX(Data Center Bridge Capabilities Exchange Protocol) IEEE 802.1Qaz
DCB devices capabilities exchange within Data Center
Модульная ОС
DCBX
M-LAG
XNV™
Direct Attach™
OpenFlow
40GE
.. протокол DCBX (data center discovery and capability exchange protocol) используется устройствами поддерживающими DCB для обмена информации о конфигурации между напрямую подключенными соседями. Протокол так же может использоваться для поиска ошибок в конфигурации параметров DCB.
High-density
IDM
18
..модульная ОС позволяет загружать и выгружать модули, активировать лицензии без прекращения работы коммутатора. Предоставляет высокую доступность и надежность. Идеальна для ЦОД, где серверы и приложения динамически перемещаются.
The Extreme Networks Solution
МодульнаяОперационная Система
Высокая надежность и непрерывность работы
DCBX
Модульная ОС
M-LAG
XNV™
Direct Attach™
OpenFlow
40GE
High-density
IDM
19
The Extreme Networks Solution
XNV™ExtremeXOS® Network Virtualization
Сеть, понимающая современные решения по виртуализации ЦОДМодульная
ОС
XNV™
Direct Attach™
DCBX
M-LAG
OpenFlow
40GE
… набор программных решений, позволяющих полностью контролировать виртуальные машины в течение их жизненного цикла на сетевом уровне, а так же предоставляющий сетевому администратору графическое средство для работы с ВМ в ЦОД.
High-density
IDM
20
The Extreme Networks Solution
Direct Attach™(VEPA)
Уменьшает количество сетевых уровней перемещая коммутацию ВМ в сеть ЦОДМодульная
ОС
XNV™
Direct Attach™
DCBX
M-LAG
OpenFlow
40GE X .. это следующая ступень развития виртуализации, позволяющая виртуальным машинам подключаться к сети напрямую, без необходимости коммутации на уровне серверного программного обеспечения. Тем самым возвращая коммутацию обратно в сеть.
High-density
IDM
21
The Extreme Networks Solution
OpenFlow Мощное средство управления коммутацией в ЦОД основанное на открытых стандартахМодульная
ОС
XNV™
DCBX
M-LAG
Direct Attach™
OpenFlow
40GE
.. это протокол, позволяющий внешнему устройству управлять forwarding tables коммутатора. OpenFlow был предложен и первоначально разработан в Стэнфордском университете для стандартизации интерфейса между forwarding plane коммутатора и control plane.
High-density
IDM
22
Summit X670: Позиционирование
Nexus 3064
Arista 7050S-64
S-Series S4810
HP 5900AF-48XG-4QSFP+(H3C)
QFX3500
23
Extreme X670 Nexus 3064 QFX3500 HP 5900 AF Arista 7050S Force10 S4810
1/10G порты 48 48 48 48 48 48
40G порты (тип)
4 (QSFP+) 4 (QSFP+)4(QSFP+ roadmap) 4 (QSFP+) 4 (QSFP+) 4 (QSFP+)
Merchant Silicon
Yes, from Broadcom
Пропускная способность
1.28 Tbps / 960 Mpps
1.28 Tbps / 950 Mpps
1.28 Tbps / 960 Mpps
1.28 Tbps / 952 Mpps
1.28 Tbps / 960 Mpps
1.28 Tbps / 960 Mpps
Dynamic Buffer 9 Mb
СтекированиеUp to 8
different - - +(only 4 same) - +(only 2 same)
Кол-во маршрутов
IPv416000 16000 16000 16000 16000 16000
L3 License (IS-IS, BGP,…) + +(2 step) + - + -
FCoE + - +(with license FC) + - -
MPLS + - + - - -
OEM optic + No info No info No info No info NOT SUPPORT
ACL (кол-во) 2048i / 1024e 2000i / 1000e 1500 1500 No info No info
LAG 16 16 32 32 16 8
Power/fans Efficient power & hot-swappable redundant fans
Кол-во MAC 128000 128000 120 000 128 000 128000 128000
ROADMAPTRILL,OpenFlow, L3VPN, etc.
No info 40GE(QSFP+), DCBx
VEPA, FCoE, TRILL
TRILL, 802.1Qaz, IPv6 TRILL, DCBx
Summit X670: Competitive Comparison
24
Please ask details at [email protected]
or our partners
Summit X670: Pricing
Part Number Summit Part Name Рекомендованная цена DDP
Обязательная поддержка (95600)
17101 Summit X670V-48x $ 34 119 $ 1 554
17122 VIM4-40G4X $ 4 089 $ 195
17103 Summit X670-48x $ 20 469 $ 1 086
17131 Summit X670 Series Core License $ 8 184 $ 462
17133 Summit X670 MPLS Feature Pack $ 5 454 $ 286
11011 Direct Attach Feature Pack $ 1 359 $ 189
10925 Summit 550W AC PSU FB $ 813 -
10926 Summit 550W DC PSU FB $ 1 086 -
25
Please ask details at [email protected]
or our partners