SUBMITTAL REVIEW - Comma-Q

25
SUBMITTAL REVIEW Submittal: No. 051.00 Spec Section: 07 9005 Joint Sealers - Acoustical Sealant Reviewed By: Laura Landon, Comma-Q Architecture Date: August 27, 2012 Project: BPS – Belgrade Elementary School Location: Belgrade, MT Job Number: 11-03 Copy to: File, Owner This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the submittals during this review do not relieve the CONTRACTOR from compliance with the requirements of the plans and specifications. An opinion of equivalence of a specific item shall not be interpreted as an opinion of equivalence of an assembly of which the item is a component. Submittal review comments have been made within this format and not on the submittal sheets according to the following: NEN No Exceptions Noted GCAN Generally Conforms as Noted RAN Rejected for Reason as Noted IAS Incomplete as Submitted 1. Submittal 51.00 - 07 9005 Joint Sealers - Acoustical Sealant Data Sheets NEN Notes: 1. None END OF REVIEW

Transcript of SUBMITTAL REVIEW - Comma-Q

SUBMITTAL REVIEW Submittal: No. 051.00 Spec Section: 07 9005 Joint Sealers - Acoustical Sealant Reviewed By: Laura Landon, Comma-Q Architecture Date: August 27, 2012 Project: BPS – Belgrade Elementary School Location: Belgrade, MT Job Number: 11-03 Copy to: File, Owner

This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the submittals during this review do not relieve the CONTRACTOR from compliance with the requirements of the plans and specifications. An opinion of equivalence of a specific item shall not be interpreted as an opinion of equivalence of an assembly of which the item is a component. Submittal review comments have been made within this format and not on the submittal sheets according to the following:

NEN No Exceptions Noted GCAN Generally Conforms as Noted RAN Rejected for Reason as Noted IAS Incomplete as Submitted

1. Submittal 51.00 - 07 9005 Joint Sealers - Acoustical Sealant Data Sheets NEN

Notes: 1. None

END OF REVIEW

TRANSMITTAL

August 24, 2012

To: Big Sky Acoustics, LLC Attention: Sean Connolly, P.E. From: Laura Landon Project: BPS – Belgrade Elementary School Location: Bozeman, MT Job Number: 11-03

Copy to: File

we are sending you : Attached

Under separate cover

the following: Shop drawings: Copy of letter: Specification: Prints: Samples: Drawings: Other:

these are transmitted as checked below:

Approved: Approved as corrected: Revise and resubmit: Rejected: For your signature: For return : For review & comment:

date qty description

8/21/2012 1 (elec) Submittal 51.00 07 9005 Joint Sealers - Acoustical Sealant

Remarks:

Sean, please review the attached submittal, please return an electronic version to our office with your comments. Thanks

MARTEL CONSTRUCTION, INC. LETTER OF TRANSMITTAL1203 South Church Avenue Bozeman, MT 59715-5801

Telephone: (406) 586-8585 Facsimile: (406) 586-8646 DATE 08/20/12 JOB NO. 12-001TRANSMITTAL/SUBMITTAL NO. 51.00

TO: Comma Q Architects RE: 05 4000 Joint Sealants - Acoustical Sealant109 North Rouse Ave #1Bozeman, MT 59715

ATTENTION: Laura Landon BELGRADE ELEMENTARY SCHOOL

We are hand delivering XWe are sending via Email

ATTACHED UNDER SEPARATE COVER TheThe following items:

Shop drawings Prints Plans Samples Specifications

Copy of letter Change order X Product Data

COPIES DATE DWG NO. DESCRIPTION

1 05 4000 Joint Sealants - Acoustical Sealant Hilti CP506, CP5727/15/12

THESE ARE TRANSMITTED as checked below:X For approval Approved as Submitted Resubmit Copies for Approval

For your use Approved as Noted Submit Copies for Distribution As requested Returned for Corrections Return Corrected Prints For review and comment

FOR BIDS DUE PRINTS RETURNED AFTER LOAN TO US

REMARKS:

COPY TO File SIGNED: Mike Wilkinson - Project Engineer

If enclosures are not as noted, kindly notify us at once.

Hilti FirestopSaving livesthrough innovationand education

Product Information

40Hilti. Outperform. Outlast.

Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide

CP 506 Smoke and Acoustic SealantApplications

■ Sealing construction joints and through-penetration openings in non fire-rated acoustical assemblies and smoke partitions (Not for use in fire-rated applications)

Advantages ■ Easy to dispense, apply and tool ■ Excellent airborne sound insulation properties ■ Low shrinkage after curing ■ Easy cleaning with water ■ Paintable

Tested/evaluated in accordance with: ■ ASTM E 90 ■ ASTM C 834 ■ ASTM E 84 ■ ASTM C 919

Technical Data CP 506Color white

Chemical basis acrylic

Storage and transport temperature range

40°F to 77°F(5°C to 25°C)

Curing time (73°F / 50% relative humidity)

approx. 3 mm / 3 days

Skin-forming time (73°F / 50% relative humidity)

approx. 15 min

Application temperature range 40°F to 104°F (5°C to 40°C)

Shelf life 24 months

Sound transmission classification (ASTM E90)

STC 63(per tested construction type)

Movement capability (ISO 11600) approx. 12.5%

Mold and mildew (ASTM G21) mold resistant

Surface burning characteristics (ASTM E 84-08)

Flame spread: 10Smoke development: 10

Air leakage (Modified UL 2079 L-Rating)

L-Rating at Ambient = Less than 1 CFM / Lin Ft.

L-Rating at 400ºF = Less than 1 CFM / Lin Ft.

Restricts smoke migration

Excellent sound insulation characteristics with application based testing in accordance with ASTM E 90.

Installation instructions for CP 506Notice • Before handling, read Material Safety Data Sheet and

product label for safe usage and health information.• Instructions below are general guidelines — always

refer to the product label, applicable product test reports and/or architect requirements

Opening1. Clean the opening. Surfaces to which CP 506 will be

applied should be cleaned of loose debris, dirt, oil, wax, grease, and other contaminants. The surface should be moisture and frost free.

Application of sealant2. Apply sealant in opening at required depth3. Smooth sealant with a trowel before the skin

forms. Once cured, CP 506 can only be removed mechanically

Not for use• In areas immersed in water

Storage• Store only in the original packaging in a location

protected from moisture at a temperature of 40°F to 77°F (5°C to 25°C)

• Observe expiration date on package

1. Clean opening 2. Apply CP 506 3. Tool CP 506

laura
New Stamp
laura
Text Box
X
laura
Text Box
Laura Landon 8/27/2012

®

MSDS No.: 326 Revision No.: 001 Revision Date: 12/01/09 Page: 1 of 2

HILTI ® is a registered trademark of Hilti Corp.

MATERIAL SAFETY DATA SHEET

Product name: CP 506 Smoke & Acoustic Sealant Description: Smoke/Acoustic Sealant for Non Fire Rated Assemblies Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121

Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries)

INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: TLV: PEL: STEL: Ethylene glycol 00107-21-1 NE NE C: 100 mg/m3 (A)Titanium dioxide 13463-67-7 10 mg/m3 15 (T) mg/m3 NE

Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. (R) = Respirable dust (T) = Total dust (A) = Aerosol

PHYSICAL DATA

Appearance: White paste. Odor: Negligible.

Boiling Point: Not applicable. Vapor Pressure: Not applicable.

Melting Point: Not determined. VOC Content: 57.0 g/l

Evaporation Rate: Not applicable. Solubility in Water: Miscible.

pH: 9.2 Specific Gravity: 1.50

FIRE AND EXPLOSION HAZARD DATA

Flash Point: Not applicable. Flammable Limits: Not applicable.

Fire / Explosion Hazards: None known.

Extinguishing Media: As appropriate for surrounding fire.

Special Fire Fighting Procedures:

As appropriate for surrounding fire.

REACTIVITY DATA

Stability: Stable. Hazardous Polymerization: Will not occur.

Incompatibility: Strong oxidizing agents.

Hazardous Decomposition Products:

Thermal decomposition can yield oxides of carbon and nitrogen.

Conditions to Avoid: Avoid temperature extremes that could shorten the shelf life of this product. See handling and storage requirements.

HEALTH HAZARD DATA

Known Hazards: Acute: Product is slightly alkaline; minor irritation is possible. Chronic: None known.

Signs and Symptoms of Exposure:

Eyes - Can cause slight irritation but injury is unlikely. Skin - Can cause irritation with some individuals. Inhalation - No effects expected. Ingestion - Not considered to be a route of exposure. Effects of ingestion have not been determined.

Routes of Exposure: Inhalation, Dermal.

Medical Conditions Aggravated by Exposure:

Eye, skin, and respiratory conditions.

Carcinogenicity: No ingredients are classified as a carcinogen by IARC, NTP or OSHA.

MSDS 326, Page 2 of 2

EMERGENCY AND FIRST AID PROCEDURES

Eyes: Flush with plenty of water. Contact a Physician if symptoms occur.

Skin: Wash with soap and water.

Inhalation: Move victim to fresh air. Call a Physician if symptoms occur.

Ingestion: Seek medical attention. Do not induce vomiting unless directed by a Physician. Never give anything by mouth to an unconscious person.

Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure.

CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT

Ventilation: General (natural or mechanically induced fresh air movements).

Eye Protection: Safety glasses with side shields.

Skin Protection: Impermeable gloves are recommended.

Respiratory Protection: Not normally required. Where ventilation is inadequate to control vapors, use a NIOSH-approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air supplied respirator.

PRECAUTIONS FOR SAFE HANDLING AND USE

Handling and Storing Precautions:

Store in a cool dry area. Keep from freezing. Shelf life is one year from date of manufacture if stored between 40° and 77° F (5 - 25° C). For industrial use only. Keep out of reach of children. Keep container sealed when not in use to prevent curing of the product. Avoid contact with the eyes and skin. Practice good hygiene; i.e. wash after using and before eating or smoking.

Spill Procedures: Allow to cure and place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. Not regulated as a hazardous waste according to federal EPA definitions.

REGULATORY INFORMATION

Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200.

HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B (Gloves, Glasses)

DOT Shipping Name: Not regulated.

IATA / ICAO Shipping Name: Not regulated.

TSCA Inventory Status: Chemical components listed on TSCA inventory.

SARA Title III, Section 313: This product contains approximately 3-4% ethylene glycol which is subject to reporting under Section 313 of SARA Title III (40 CFR Part 372).

EPA Waste Code(s): Not regulated by EPA as a hazardous waste.

Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations.

CONTACTS

Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000

Health / Safety: 1 800 879 6000 Jerry Metcalf (x1003704)

Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries)

The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided.

Hilti, Inc. 5400 South 122nd East Avenue

Tulsa, OK 74146

1-800-879-8000 www.hilti.com

November 30, 2009 To Whom It May Concern: Re: Hilti CP 506 Smoke & Acoustic Sealant – LEEDs Info. The Hilti CP 506 Smoke & Acoustic Sealant is manufactured in Germany. There is no post-consumer or post-industrial content in CP 506 and it cannot be recycled. The CP 506 does not contain any Rapidly Renewable Materials. The VOC content for CP 506 is 57 g/l. CP 506 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely,

Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc. 918 872 3704 [email protected] Rev. Date: 11/30/09

Hilti FirestopSaving livesthrough innovationand education

Product Information

41Hilti. Outperform. Outlast.Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide

CP 572 Smoke and Acoustic SprayApplications

■ Sealing construction joint openings in non fire-rated acoustical assemblies and smoke partitions (Not for use in fire-rated applications)

Advantages ■ Quick and easy spray application ■ Can be applied at low temperatures ■ Excellent airborne sound insulation properties ■ High elasticity for good movement absorption ■ Excellent sprayability and low slump characteristics ■ Paintable

Technical Data CP 572Color white

Chemical basis acrylic

Storage and transport temperature range

40°F to 77°F (5°C to 25°C)

Curing time approx. (73°F / 50% relative humidity)

approx. 3 mm / 3 days

Skin-forming time (73°F / 50% relative humidity)

approx. 15 min

Application temperature range 40°F to 104°F (5°C to 40°C)

Shelf life 12 months

Sound transmission classification (ASTM E 90)

STC 56(per tested construction type)

Surface burning characteristics (ASTM E 84-08)

Flame spread: 10Smoke development: 5

Movement capability approx. 12.5%

Mold and mildew (ASTM G21) mold resistant

Air leakage(Modified UL 2079 L-Rating)

L-Rating at Ambient =Less than 1 CFM / Lin Ft.

L-Rating at 400ºF =Less than 1 CFM / Lin Ft.

Restricts smoke migration

Excellent sound insulation characteristics with application based testing in accordance with ASTM E 90.

Installation instructions for CP 572Notice • Before handling, read Material Safety Data Sheet and

product label for safe usage and health information.• Instructions below are general guidelines — always

refer to the product label, applicable product test reports and/or architect requirements.

Opening1. Clean the opening. Surfaces to which CP 572 will be

applied should be cleaned of loose debris, dirt, oil, wax, grease, and contaminants. The surface should be moisture and frost free.

Application of spray2. Install mineral wool backing to required depth3. Application of spray: Apply CP 572 to the required

depth in order to obtain desired sound rating. Make sure CP 572 contacts all surfaces and overlaps beyond all surrounding surfaces (Refer to test reports). Titan Sprayers have been successful in applying CP 572 Smoke and Acoustic Spray. Hilti recommends the use of the Titan 600 (for application temperatures above 50°F) or 1100 Sprayers. CP 572 may also be brushed on with a paint brush.

Not for use• In areas immersed in water• On hot surfaces (above 176°F)

Storage• Store only in the original packaging at temperatures

40°F to 77°F (5°C to 25°C)• Observe expiration date on package

1. Clean opening 2. Install mineral wool 3. Spray or brush on CP 572

Product Information

Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com • en español 1-800-879-5000 • Hilti (Canada) Corp. 1-800-363-4458 www.hilti.ca

Hilti. Outperform. Outlast.11/2009

Installation instructions for CP 572Notice • Before handling, read Material Safety Data Sheet and

product label for safe usage and health information.

• Instructions below are general guidelines — always refer to the product label, applicable product test reports and/or architect requirements.

Opening1. Clean the opening. Surfaces to which CP 572 will be

applied should be cleaned of loose debris, dirt, oil, wax, grease, and contaminants. The surface should be moisture and frost free.

Application of spray2. Install mineral wool backing to required depth

3. Application of spray: Apply CP 572 to the required depth in order to obtain desired sound rating. Make sure CP 572 contacts all surfaces and overlaps beyond all surrounding surfaces (Refer to test reports). Spray Tech Sprayers have been successful in applying CP 572 Smoke and Acoustic Spray. Hilti recommends the use of the Spray Tech EPX 2355 (for application temperatures above 50°F) or EPX 2555 Sprayers. CP 572 may also be brushed on with a paint brush

Not for use• In areas underwater

• On hot surfaces (above 176°F)

Storage• Store only in the original packaging at temperatures

40°F to 77°F (5°C to 25°C)

• Observe expiration date on package

1. Clean opening 2. Install mineral wool 3. Spray or brush on CP 572

General guidelines for common acoustic seal applications

NoteThese are suggested installation guidelines for common applications �

Obtain architect and appropriate authority having jurisdiction approval �for specific application of use prior to installation

For additional details refer to specific Hilti sound transmission and air �leakage test reports

Not for use in fire-rated assemblies �

Top of Wall (one sided installation)

System STC = 54(refer to STC test report for wall construction details)

®

MSDS No.: 327 Revision No.: 001 Revision Date: 12/01/09 Page: 1 of 2

HILTI ® is a registered trademark of Hilti Corp.

MATERIAL SAFETY DATA SHEET

Product name: CP 572 Smoke & Acoustic Spray Description: Smoke/Acoustic Spray for Non Fire Rated Assemblies

Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121

Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries)

INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: TLV: PEL: STEL: Ethylene glycol 107-21-1 NE NE C: 100 mg/m3 (A) Titanium dioxide 13463-67-7 10 mg/m3 15 (T) mg/m3 NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. C = Ceiling. NE = None Established. (T) = Total dust. (R) = Respirable dust. (A) = Aerosol

PHYSICAL DATA

Appearance: White sprayable paste Odor: Mild odor

Vapor Density: (air = 1) Not applicable Vapor Pressure: Not determined

Boiling Point: Not determined VOC Content: 91.0 g/l

Evaporation Rate: Not determined Solubility in Water: Soluble

Specific Gravity: 1.5 pH: 9.0

FIRE AND EXPLOSION HAZARD DATA

Flash Point: None Flammable Limits: Not applicable

Extinguishing Media: As appropriate for surrounding fire (e.g. Water, Carbon Dioxide, Dry Chemical, Foam)

Special Fire Fighting Procedures:

Wear full protective clothing. A NIOSH-approved self-contained breathing apparatus (SCBA) should be worn when fighting fires involving chemicals.

Unusual Fire and Explosion Hazards:

None known. Thermal decomposition products such as oxides of carbon and nitrogen can be produced under fire conditions. See below.

REACTIVITY DATA

Stability: Stable. Hazardous Polymerization: Will not occur.

Incompatibility: Strong oxidizing agents.

Hazardous Decomposition Products:

Thermal decomposition can yield oxides of carbon and nitrogen.

Conditions to Avoid: Avoid temperature extremes which could shorten the shelf-life of this product; i.e. below 40° and above 77° F. (See handling and storage requirements).

HEALTH HAZARD DATA

Known Hazards: Acute: Product is slightly alkaline, minor irritation is possible. Chronic: None known

Signs and Symptoms of Exposure:

Eyes: Can cause irritation or watering but injury is unlikely. Skin: Irritation is possible with some individuals. Inhalation: No effects expected. Ingestion: Effects of ingestion have not been determined. Considered to have a low acute oral toxicity.

Routes of Exposure: Contact.

Carcinogenicity: No ingredients are classified as a carcinogen by IARC, NTP or OSHA.

Medical Conditions Aggravated by Exposure:

None known

MSDS 327, Page 2 of 2

EMERGENCY AND FIRST AID PROCEDURES

Eyes: Flush with plenty of water. Contact a Physician if symptoms occur.

Skin: Wash with soap and water. Seek medical attention if any effects persist.

Inhalation: Move victim to fresh air. Contact a Physician if symptoms occur.

Ingestion: Do not induce vomiting unless directed by a Physician. Contact a Physician immediately.

Other: Referral to a Physician is recommended if there is any question about the seriousness of the injury/exposure.

CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT

Ventilation: General (natural or mechanically induced fresh air movements).

Eye Protection: While spraying, chemical goggles are recommended. As a minimum, wear safety glasses with side shields. Wear other protective clothing as required to prevent contact with skin.

Skin Protection: Impermeable gloves recommended.

Respiratory Protection: None normally required.

PRECAUTIONS FOR SAFE HANDLING AND USE

Handling and Storing Precautions:

Store in a cool dry area. Keep from freezing. Store between 40° and 77° F. For industrial use only. Keep out of reach of children. Use with adequate ventilation. Keep container closed when not in use. Do not get into the eyes. Avoid prolonged or repeated contact with the skin. Practice good hygiene; i.e. wash after using and before eating or smoking.

Spill Procedures: Wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state, or federal requirements.

REGULATORY INFORMATION

Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard. 29 CFR 1910.1200.

HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B (Glasses, Gloves)

DOT Shipping Name: Not regulated.

IATA / ICAO Shipping Name: Not regulated.

TSCA Inventory Status: Chemical components listed on TSCA inventory.

SARA Title III, Section 313: This product contains 3 – 4% ethylene glycol (CAS 107-21-1) which is subject to reporting under Section 313 of SARA Title III (40 CFR Part 372).

EPA Waste Code(s): Not regulated by EPA as a hazardous waste

Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations.

CONTACTS

Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000

Health / Safety: 1 800 879 6000 Jerry Metcalf (x1003704)

Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries)

The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided.

Hilti, Inc. 5400 South 122nd East Avenue

Tulsa, OK 74146

1-800-879-8000 www.hilti.com

November 30, 2009 To Whom It May Concern: Re: Hilti CP 572 Smoke & Acoustic Sealant – LEED Info. The Hilti CP 572 Smoke & Acoustic Sealant is manufactured in Germany. The CP 572 pail is made of polyethylene and can be completely recycled. There is no post-consumer or post-industrial content in CP 572 and it cannot be recycled. The CP 572 does not contain any Rapidly Renewable Materials. The VOC content of CP 572 is 91 g/l. CP 572 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely,

Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc w (918) 872 3704 [email protected] Rev. Date: 11/30/09