Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV Page 1 of 4 Samsung "Wind-Free", wall mounted evaporator, split system www.SamsungHVAC.com Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. *The Wind-Freeunit delivers an air current that is under 0.15 m/s while in Wind Free mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air- Conditioning Engineers). AR24NSWXCWKCV AR24NSWXCWKNCV Nominal Capacity 1 Cooling / Heating (Btu/h) 21,000 / 27,500 Cooling (Btu/h) 8,800 - 31,700 Heating (Btu/h) 7,500 - 41,000 20.0 / 12.5 3.36 10.00 202022722 Voltage ø / V / Hz 1 / 208-230 / 60 176 - 254 Cooling (A) 2.4 / 6.2 / 11.2 Heating (A) 2.3 / 7.3 / 17.1 Max. Breaker Amps 30 20.0 Indoor Unit 41 15/16 X 11 7/8 X 12 1/4 Outdoor Unit 37 X 39 11/16 X 13 Indoor Unit 31.75 Outdoor Unit 147.7 11/16" OD Indoor Unit (dB) Low / High 28 / 47 Outdoor Unit (dB) High 56 14 ~ 115°F (-10 ~ 46°C) -0.4 ~ 115°F(-18 ~ 46°C) W/Baffle Heating 5 ~ 75°F (-15 ~ 24°C) Cooling 61 ~ 90°F (16 ~ 32°C) Heating T ≤ 80°F (27°C) High side (flare) 1/4" Low side (flare) 5/8" 98 / 10 66 R410A Electronic Expansion Valve Factory Charge oz. 88.16 25 feet 0.16 oz./ft. over 25 ft. Samsung BLDC Rotary RLA A 15.2 BLDC motor with cross-flow fan (1) Air Volume CFM (L/M/H/Turbo) 403 / 494 / 586 / 660 Consumption Watts 27 X 1 FLA Amps 0.12 BLDC motor with axial fan (1) Output Watts 125 FLA Amps 0.48 Air Volume CFM (max.) 2,825 Condenser Fan AHRI Reference Number Specifications Model System Model Number Indoor Unit Model Number Outdoor Unit Model Number Power Working Voltage Range (VAC) Operating Current (Min./Std./Max.) Performance Capacity Range SEER / EER HSPF Min. Circuit Ampacity (A) COP Sound Pressure Level Condensate Connection Dimensions W X H X D (in.) Weight (lbs.) Pipe Connections Indoor & Outdoor Maximum / Minimum Line Set Length (ft.) Maximum Vertical Separation (ft.) Operating Temperatures °F(°C) Outdoor Cooling Indoor Refrigerant Type Control Method Charged for Additional Refrigerant Compressor Manufacturer Type Evaporator Fan Type Motor AR24NSWXCWKXCV DFWXDO HTXLSPHQW DSSHDUDQFH PD\ YDU\ General Information •The indoor unit shall feature Wind-Freemode*. In cooling mode, as room temperature nears set temperature, the unit will close its louver and will disperse air into the space through over 20,000 micro-holes on the front of the indoor unit preventing cold air drafts on occupants. • The indoor unit shall have Wi-Fi capability as standard for control and monitoring with the Samsung SmartThings app (Android, iOS) • Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3 interconnect power cable • Electro-static, washable, main filter as standard accessible from the front/top of unit • Advanced air filtration Construction • Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability The indoor unit shall have easy-access to wire, pipe, and drain connections via access panel on front of unit for easier installation and service Heat Exchanger • The heat exchanger shall be mechanically bonded fin to copper tube Refrigerant System • The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary • Refrigerant flow shall be controlled by electronic expansion valve at outdoor unit Indoor Fan • The indoor fan shall be a single, antibacterial cross-flow type • Three fan speed settings and auto setting • Automatic (motorized) vertical swing louver (up/down) Controls • The system shall have a built in Wi-Fi adapter as standard to allow control remotely (details on page 4) • Control signal shall be DDC type signal • Interconnect control wiring shall be 16 AWG X 2 shielded wire between outdoor and indoor units • The indoor unit shall ship with a wireless controller and batteries as standard • Optional wired control options available • Samsung central control compatible 4 Convenience Wind-Freemode Auto restart • 7-segment digital display on front of unit to display temperature and unit status (hidden behind louver when off) • "Fast Comfort" mode to quickly reach set temperature • Auto changeover • 24 hour, single event timer • Good'sleep mode • Quiet mode • Dry mode • Single event, ON/OFF timer • Single User Mode to reduce energy consumption during low demand operation • Air filter cleaning can be done easily without opening the indoor unit • Smart install mode - startup system diagnostics operation to ensure system readiness during initial operation • Display ON/OFF and beep ON/OFF with included wireless controller Nominal Heating Aspen Mini Orange ASP-MO-UNIV 110-250 Blue Diamond BD-BLUE-230 Standard Kit 2 AR-WRS02 Premium Kit (w/scheduling) 3 AR-WRP2 DB93-11412A DB93-11405A MIM-B14 CKN-250 25' - ILS2509 50' - ILS5009 Front WBF-2M Back WBB-3M Certifications Devices Warranty Wired controller sub-PCB harness Wired controller sub-PCB External contract control interface module (requires sub-PCB and sub-PCB harness) Optional Accessories Wired controller Wall bracket (for outdoor unit) Condensate pump Safety ETL (UL 1995) PCB fuses, indoor unit terminal block thermal fuse, current transformer, over-voltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing 10 Years compressor, 10 Year Parts, 1 year limited labor (registration required) Line sets - insulated and flared, interconnect cables included Wind Baffle / Guard 1 Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps (USHP) Certification Program which is based on the latest edition of AHRI Standard 210/240. 2 AR-WRS02 includes MWR-WH02 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). 3 AR-WRP includes MWR-WE10 wired controller with scheduling, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). 4 When connecting to central controls using MIM-N01, a sub PCB must also be installed. Refer to technical bulletin at www.DVMdownload.com Centeral control interface module (NASA) 4 MIM-N01 © 2018 Samsung HVAC SHA-RAC-09192018 Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

Transcript of SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV … · Job Name Location Purchaser Engineer Submitted to...

Page 1: SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV … · Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24NSWXCWKXCV

Job Name LocationPurchaser EngineerSubmitted to Reference Approval ConstructionUnit Designation Schedule #

SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV Page 1 of 4

Samsung "Wind-Free™", wall mounted evaporator, split system

www.SamsungHVAC.com

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers.

*The Wind-Free™ unit delivers an air current that is under 0.15 m/s while in Wind Free mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers).

AR24NSWXCWKCVAR24NSWXCWKNCV

Nominal Capacity1 Cooling / Heating (Btu/h) 21,000 / 27,500Cooling (Btu/h) 8,800 - 31,700Heating (Btu/h) 7,500 - 41,000

20.0 / 12.53.36

10.00202022722

Voltage ø / V / Hz 1 / 208-230 / 60176 - 254

Cooling (A) 2.4 / 6.2 / 11.2Heating (A) 2.3 / 7.3 / 17.1

Max. Breaker Amps 3020.0

Indoor Unit 41 15/16 X 11 7/8 X 12 1/4Outdoor Unit 37 X 39 11/16 X 13Indoor Unit 31.75Outdoor Unit 147.7

11/16" OD

Indoor Unit (dB) Low / High 28 / 47Outdoor Unit (dB) High 56

14 ~ 115°F (-10 ~ 46°C)-0.4 ~ 115°F(-18 ~ 46°C) W/Baffle

Heating 5 ~ 75°F (-15 ~ 24°C)Cooling 61 ~ 90°F (16 ~ 32°C)Heating T ≤ 80°F (27°C)

High side (flare) 1/4"Low side (flare) 5/8"

98 / 1066

R410AElectronic Expansion Valve

Factory Charge oz. 88.1625 feet

0.16 oz./ft. over 25 ft.

SamsungBLDC Rotary

RLA A 15.2

BLDC motor with cross-flow fan (1)Air Volume CFM (L/M/H/Turbo) 403 / 494 / 586 / 660Consumption Watts 27 X 1FLA Amps 0.12

BLDC motor with axial fan (1)Output Watts 125FLA Amps 0.48Air Volume CFM (max.) 2,825

Condenser Fan

AHRI Reference Number

Specifications

ModelSystem Model NumberIndoor Unit Model NumberOutdoor Unit Model Number

Power

Working Voltage Range (VAC)Operating Current (Min./Std./Max.)

Performance

Capacity Range

SEER / EER

HSPF

Min. Circuit Ampacity (A)

COP

Sound Pressure Level

Condensate Connection

Dimensions

W X H X D (in.)

Weight (lbs.)

Pipe ConnectionsIndoor & Outdoor

Maximum / Minimum Line Set Length (ft.)Maximum Vertical Separation (ft.)

Operating Temperatures °F(°C)

Outdoor Cooling

Indoor

Refrigerant

TypeControl Method

Charged for Additional Refrigerant

CompressorManufacturerType

Evaporator Fan

Type

Motor

AR24NSWXCWKXCV

General Information• The indoor unit shall feature Wind-Free™ mode*. In cooling mode, as room temperature nears set temperature, the unit will close its louver and will disperse air into the space through over 20,000 micro-holes on the front of the indoor unit preventing cold air drafts on occupants. • The indoor unit shall have Wi-Fi capability as standard for control andmonitoring with the Samsung SmartThings app (Android, iOS)• Outdoor unit shall provide 208/230V power to indoor unit via 14 AWG X 3interconnect power cable• Electro-static, washable, main filter as standard accessible from the front/top ofunit• Advanced air filtration

Construction• Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket• The outdoor unit shall be galvanized steel with a baked on powder coated finishfor durability

• The indoor unit shall have easy-access to wire, pipe, and drain connections viaaccess panel on front of unit for easier installation and service

Heat Exchanger• The heat exchanger shall be mechanically bonded fin to copper tube

Refrigerant System• The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary• Refrigerant flow shall be controlled by electronic expansion valve at outdoor unit

Indoor Fan• The indoor fan shall be a single, antibacterial cross-flow type• Three fan speed settings and auto setting• Automatic (motorized) vertical swing louver (up/down)

Controls• The system shall have a built in Wi-Fi adapter as standard to allow controlremotely (details on page 4)

• Control signal shall be DDC type signal• Interconnect control wiring shall be 16 AWG X 2 shielded wire between outdoorand indoor units

• The indoor unit shall ship with a wireless controller and batteries as standard• Optional wired control options available• Samsung central control compatible 4

Convenience• Wind-Free™ mode• Auto restart• 7-segment digital display on front of unit to display temperature and unit status(hidden behind louver when off)• "Fast Comfort" mode to quickly reach set temperature• Auto changeover• 24 hour, single event timer• Good'sleep mode• Quiet mode• Dry mode• Single event, ON/OFF timer• Single User Mode to reduce energy consumption during low demand operation •Air filter cleaning can be done easily without opening the indoor unit• Smart install mode - startup system diagnostics operation to ensure systemreadiness during initial operation• Display ON/OFF and beep ON/OFF with included wireless controller

Nominal Heating

Aspen Mini Orange ASP-MO-UNIV 110-250Blue Diamond BD-BLUE-230Standard Kit 2 AR-WRS02Premium Kit (w/scheduling) 3 AR-WRP2

DB93-11412ADB93-11405A

MIM-B14

CKN-250 25' - ILS250950' - ILS5009

Front WBF-2MBack WBB-3M

Certifications

Devices

Warranty

Wired controller sub-PCB harnessWired controller sub-PCB

External contract control interface module (requires sub-PCB and sub-PCB harness)

Optional Accessories

Wired controller

Wall bracket (for outdoor unit)

Condensate pump

Safety

ETL (UL 1995)PCB fuses, indoor unit terminal block thermal fuse, current transformer, over-voltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing

10 Years compressor, 10 Year Parts, 1 year limited labor (registration required)

Line sets - insulated and flared, interconnect cables includedWind Baffle / Guard

1 Certified in accordance with the AHRI Unitary Small Air-Source Heat Pumps (USHP) Certification Program which is based on the latest edition of AHRI Standard 210/240.2 AR-WRS02 includes MWR-WH02 wired controller, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A).3 AR-WRP includes MWR-WE10 wired controller with scheduling, sub-PCB (DB93-11412A), and sub-PCB harness (DB93-11405A). 4 When connecting to central controls using MIM-N01, a sub PCB must also be installed. Refer to technical bulletin at www.DVMdownload.com

Centeral control interface module (NASA) 4 MIM-N01

© 2018 Samsung HVAC SHA-RAC-09192018

Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

Page 2: SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV … · Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24NSWXCWKXCV

Unit: inches

888-699-6067 www.SamsungHVAC.com

SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV Page 2 of 4

Samsung "Wind-Free™", wall mounted evaporator, split system Indoor unit dimensional drawing

41 15/16"12 1/4"

3 5/

16"

4"

11 7

/8"

Perforated Panel

2 1/2"

2 7/16"

5 3/16"41 15/16"

11 1/4"

11 7

/8"

1 5/

16"

15/1

6"

4 5/16"

3 5/16"

22 7/16"

3 5/16"

1 5/

16"

4 5/16"

6 5/8"

Φ 2 9

/16"Φ 2 9/16"

Page 3: SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV … · Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24NSWXCWKXCV

Unit: inches

Minimum clearance from walls and ceiling

L1 L2

L1 L2

F1 F2

F1 F2

L1 L2 F1 F2

Indoor Unit

Outdoor Unit

CommunicationMain Power

Basic power and communication wiringbetween indoor and outdoor units

888-699-6067 www.SamsungHVAC.com

SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV Page 3 of 4

Samsung "Wind-Free™", wall mounted evaporator, split system Outdoor unit dimensional drawing

4 - ø15/32"

37"

37" 11 5/16"

24 7/16"

38 5

/8"

25 11/16

"

39 11/16

"

15 1

/8"

19 5

/16" 27

5/1

6"

TOP

FRONT

FRONT WITHOUT SERVICE COVER

13"

No. Description

Liquid service valve2Suction service valve

3 Drainage hole

1

4 Power and communication conduit openings

Page 4: SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV … · Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AR24NSWXCWKXCV

SUBMITTAL AR24NSWXCWKXCV / AR24NSWXCWKNCV Page 4 of 4

Samsung "Wind-Free™", wall mounted evaporator, split system Samsung SmartThings App Wi-Fi Control Details

• Samsung's "SmartThings" app can monitor and control anunlimited quantity indoor units.

• A network with Wi-Fi connectivity is required to use the Wi-Fiadapter. Wi-Fi-direct control is not possible.

• Allows control of system on a local network via Wi-Fi orthrough the internet when outside of home/office with Samsung's "SmartThings" app (available in Android and Apple app stores).

• Basic control and monitoring of: power, mode, settemperature, room temperature, fan speed, and louver swing.

• Timer ON and OFF feature allows scheduling of power ONand power OFF events on specific days at specific times.

• "My Wind" functions allows the user to save common airconditioner control configurations for quick and easy system operation (mode, set temperature, fan speed, and louver swing).

• Air filter reminder option will display hours of fan operationsince last filter reminder reset.

• Optional filter reminder with four reminder intervals (180, 300,500, and 700 hours of fan operation).

• Error notification

"My Wind" settings page

Timer setting page exampleMain control page Filter reminder setting page

Things

Options and settings pages

888-699-6067 www.SamsungHVAC.comNOTE: App features and layout are subject to removal or change without notice.