4
SUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design and Heavy Duty Motor Construction 20, 25, 30, 40, and 50 Horsepower Motors 3 Phase - 200 Volt ---- 230/460 Volt ---- 575 Volt Available 80 Starts per Hour Class B Insulation Systems Pumps mount directly to Motor, no adapters needed Stocked for Immediate Shipment Call 330 734-3600 IMPERIAL ELECTRIC 1503 Exeter Road Akron, Ohio 44306 [email protected] www.nidec-ise.com

Transcript of SUBMERSIBLE HYDRAULIC MOTORS - Imperial ElectricSUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design...

Page 1: SUBMERSIBLE HYDRAULIC MOTORS - Imperial ElectricSUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design and Heavy Duty Motor Construction 20, 25, 30, 40, and 50 Horsepower Motors 3 Phase

SUBMERSIBLE HYDRAULIC MOTORS

FEATURES

Robust Design and Heavy Duty Motor Construction

20, 25, 30, 40, and 50 Horsepower Motors

3 Phase - 200 Volt ---- 230/460 Volt ---- 575 Volt Available

80 Starts per Hour

Class B Insulation Systems

Pumps mount directly to Motor, no adapters needed

Stocked for Immediate Shipment

Call 330 734-3600IMPERIAL ELECTRIC

1503 Exeter Road Akron, Ohio 44306

[email protected] www.nidec-ise.com

Page 2: SUBMERSIBLE HYDRAULIC MOTORS - Imperial ElectricSUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design and Heavy Duty Motor Construction 20, 25, 30, 40, and 50 Horsepower Motors 3 Phase

Rev 4/19/2017

HP Imperial Electric Part Number

Motor Losses BTU/HR

FL EFF (%)

FL PF (%) FL RPM Volts

Amps (A)

Delta WYE

"Full Load"

"No Load"

"Locked Rotor"

"KVA Code"

"Locked Rotor"

15217EAS015C001

14,120 73 87 3400200 51.0 27.0 242

F82

217EAS015C015 230/460 44.6/22.3 23.0/11.5 204/102 68/34

20217EAS020C001

16,074 76 89 3395200 65.4 31.2 311

F104

217EAS020C015 230/460 56.2/28.1 25.5/12.8 270/135 90/45

25217EAS025C001

17,946 78 91 3400200 78.2 34.5 391

F130

217EAS025C015 230/460 67.8/33.9 30.0/15.0 340/170 113/57

30217EAS030C001

20,296 79 91 3390200 90.0 36.0 471

F157

217EAS030C015 230/460 78.2/39.1 31.0/15.5 410/205 136/68

40217EAS040C001

23,879 81 91 3410200 120.0 46.0 671

G224

217EAS040C015 230/460 104/52.0 40.0/20.0 584/292 195/97

50217EAS050C001

29,861 81 91 3380200 142.0 42.7 920

G307

217EAS050C015 230/460 123/61.5 37.5/18.8 800/400 268/133

Submersible Hydraulic Elevator Motor Standard Ratings

AC Squirrel Cage Induction, Ball Bearing, 80 Starts Per Hour 3Ø, 60Hz, WYE Start, Delta Run, 3600 Synchronous RPM

* 200 Volt Motors are Designed for Operation at 208 Volts

Imperial Electric 1503 Exeter Road Akron, OH 44306Phone: (330) 734-3600 Fax: (330) 734-3601 www.nidec-ise.com

Dennis Rhodes Senior Sales [email protected]. 3683

Contact:

Page 3: SUBMERSIBLE HYDRAULIC MOTORS - Imperial ElectricSUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design and Heavy Duty Motor Construction 20, 25, 30, 40, and 50 Horsepower Motors 3 Phase

Rev 4/19/2017

HP Imperial Electric Part Number

Motor Losses BTU/HR

FL EFF (%)

FL PF (%) FL RPM Volts

Amps (A)

Delta WYE

"Full Load"

"No Load"

"Locked Rotor"

"KVA Code"

"Locked Rotor"

10

217EAS010C001 3470 200 38.0 27.0 242 K 82

217EAS010C015 3470230 33.0 23.0 204 K 68

460 16.5 11.5 102 K 34

3470 575 13.2 9.2 84 K 30

15

217EAS015C002 3450 200 52.0 31.2 311 J 104

217EAS015C011 3450230 46.0 25.5 270 J 90

460 23.0 12.8 135 J 45

3450 575 18.4 10.2 108 J 36

20

217EAS020C001 3440 200 63.3 34.5 391 H 130

217EAS020C012 3410230 57.0 30.0 340 H 113

460 28.5 15.0 170 H 57

3410 575 21.5 11.3 136 H 45

25

217EAS025C002 3440 200 76.0 36.0 471 H 157

217EAS025C016 3440230 68.0 31.0 410 H 136

460 34.0 15.5 205 H 68

3440 575 27.2 12.0 174 H 58

30

217EAS030C003 3460 200 92.0 46.0 671 J 224

217EAS030C017 3460230 80.0 40.0 584 J 195

460 40.0 20.0 292 J 97

3460 575 32.0 16.0 234 J 78

40

217EAS040C003 3430 200 115.0 42.7 920 J 307

217EAS040C018 3410230 102.0 37.5 800 J 268

460 51.0 18.8 400 J 133

3410 575 41.0 15.0 320 J 106

AC Squirrel Cage Induction, Ball Bearing, 120 Starts Per Hour 3Ø, 60Hz, WYE Start, Delta Run, 3600 Synchronous RPM

* 200 Volt Motors are Designed for Operation at 208 Volts

Imperial Electric 1503 Exeter Road Akron, OH 44306Phone: (330) 734-3600 Fax: (330) 734-3601 www.nidec-ise.com

Dennis Rhodes Senior Sales [email protected]. 3683

Contact:

Submersible Hydraulic Elevator Motor Standard Ratings

Page 4: SUBMERSIBLE HYDRAULIC MOTORS - Imperial ElectricSUBMERSIBLE HYDRAULIC MOTORS FEATURES Robust Design and Heavy Duty Motor Construction 20, 25, 30, 40, and 50 Horsepower Motors 3 Phase

Rev 4/19/2017

SUBMERSIBLE MOTOR DATA

IEC M/N HP LKD BTU/HR FL FL VOLTS LRA NLA217EAS CODE LOSSES EFF PF FL FLA DELTA DELTA

KVA/A RPM DELTA015C001 15 F 14,120 0.73 0.87 200 222.0 27.0015C015 3400 230 51.0 189.0 23.0015C015 460 44.6 94.5 11.5015C020 575 22.3 75.0 9.2

17.6020C001 20 E 16,074 0.76 0.89 200 279.0 31.2020C015 3395 230 65.4 246.0 25.5020C015 460 56.2 123.0 12.8020C020 575 28.1 102.0 10.2

22.4025C001 25 E 17,946 0.78 0.91 200 342.0 34.5025C015 3400 230 78.2 298.0 30.0025C015 460 67.8 149.0 15.0025C020 575 33.9 114.0 11.3

26.9030C001 30 F 20,296 0.79 0.91 200 441.0 36.0030C015 3390 230 90.0 380.0 31.0030C015 460 78.2 190.0 15.5030C020 575 39.1 154.0 12.0

31.2040C001 40 F 23,879 0.81 0.91 200 600.0 46.0

040C015 3410 230 120.0 520.0 40.0

040C015 460 104.0 260.0 20.0040C020 575 52.0 208.0 16.0

42.0050C001 50 F 29,861 0.81 0.91 200 727.0 42.7050C015 3380 230 142.0 634.0 37.5050C015 460 123.0 317.0 18.8050C020 575 61.5 279.0 15.0

49.4

Submersible Hydraulic Elevator Motor Standard Ratings

AC/DC, 240 Volt DC, Standard Reconnectable Series Fields, Ball Bearing, 50ºC RiseContinuous Duty, Open Construction, Elevator Service, 1800 RPM

Imperial Electric 1503 Exeter Road Akron, OH 44306Phone: (330) 734-3600 Fax: (330) 734-3601 www.nidec-ise.com

Dennis Rhodes Senior Sales [email protected]. 3683

Contact: