EN High efficiency submersible electric pumps NOVEMBER 2013 I E 3 P R E M I U M E F F I C I E N C Y

Transcript of submersible electric pumps - VIP Tehnika - Prodaja in ... · In civil and industrial applications...

EN

High effi ciency submersible electric pumps

NOVEMBER2013NOVEMBER2013

IE3

PREMIUM EFFIC

IEN

CY

IE3

PREMIUM EFFIC

IEN

CY

CO2 emissions reduction, lower costs and environmental protection, these are

issues that affect us all closely and which we need to take care of for the sake

of future generations.

UNIQA motors correspond to IE3 effi ciency class and match S1 duty type

standards for submerged operation at a temperature of 60° C, as per NEMA A.

In civil and industrial applications the reliability of a submersible electric pump

is a synonym for smooth operation, steady performance and continuous work

cycles without undesired system shutdowns.

For this reason, UNIQA is made of innovative materials and is equipped with

cutting-edge technical features such as the new patented cooling system. All

these attributes make UNIQA a safe and reliable product.

The UNIQA range represents the perfect solution for any domestic, commercial

and industrial applications, with a choice of 2, 4, 6 or 8 pole motors from 4 to

200 kW, 50 and 60Hz, and discharge ports from DN65 to DN400. The vortex

impeller that allows for wider free passage, paired with the anti-clogging

system, guarantees the optimum performance of every UNIQA model in any

circumstance.

High effi ciency submersible electric pumps

2013 CATALOGUE50Hz

4

2013 CATALOGUE - 50HZ

In emerging countries, the second largest expense in municipal budgets is generally the energy cost of water supplies. This situation is worsened by the fact that by 2020, 50% of the population of these countries will have moved to urban centres.

It is therefore clear that the energy consumed in supply drinking water and treating black water is destined to grow; at the present time, around 3% of world energy consumption is accounted by the pumping and tre-atment of civil and industrial water.

It is critical that water systems be as efficient as possible, while reducing wastage to a minimum.

Life Cycle Cost consists of 3 basic factors: initial costs, energy costs and maintenance. It must be remembered that a pump or system’s energy costs, together with installation, environmental, disposal and stoppage costs, account for 85 per cent of the total cost. Maintenance then amounts to an additional 5 per cent. It thus becomes clear that the initial cost only accounts for 10 per cent of LCC.

Imagine the LCC as an iceberg, of which only 10% is visible, while the remaining 90% is concealed from view; in same way, the cost of an installation makes evident only the initial investment and conceals running and maintenance costs, which are by far greater than the initial purchase price.

Therefore, giving a submersible pump a highly efficient motor and internal components can guarantee impressi-ve energy savings, recouping the extra investment compared to the purchase of a pump with the same hydraulic characteristics but poorer energy efficiency within just two years*.

*Regular inspection of the system’s components, operation and performance is essential for the achievement of efficiency targets.

Only use what you need:less waste, improved efficiency.

LCC: Life Cycle Cost

The UNIQA solutionStarting from these considerations, Zenit has decided to orient its strategy towards the creation of products which satisfy restrictive efficiency and reliability criteria, thus minimising outages and running costs.

UNCOMPROMISING EFFICIENCY

To reach the levels of efficiency set out in modern international standards, such as “NEMA A”, Zenit has taken an uncompromising approach with UNIQA, a product intended to last for years in both civil and industrial set-tings, and which provides performance to efficiency class Premium IE3.

A wide choice of motors, from 4 to 200 kW with 2, 4, 6 and 8 pole windings, 50 / 60Hz power and DN65 to DN400 discharge ports, vortex impellers with full free passage and channels with anti-blockage systems, make the UNIQA series ideally suited to operation in any conditions.

The generously rated mechanical assemblies provide long service life, with long maintenance intervals and redu-ced downtime - all of which adds up to cost savings.

Performance is constant in continuous operation without costly downtime. The reliability of the submersible pump means smooth, regular operation. This is why UNIQA is made of innovative materials, using cutting edge technologies and a new patented cooling system.

5

1.240€

2013 CATALOGUE - 50HZ

The combination of efficient motors, high hydraulic performance and reliability give UNIQA a particularly high global efficiency rating, capable of ensuring a good return on investment over time.

For a real understanding of how efficient UNIQA is, let’s take a look at the figures for a small pumping station. Let’s suppose we have calculated a “duty point” with a flow rate of 30 l/sec, lifted to a height of 13.5 m.

We now know we need a hydraulic power of 3,973 kW (Pidr = ρ ● g ● Q ● H), for a total of 10 working hours a day (365 days/year),with an energy cost per kWh of 0.10 € /kWh. This is what our equipment aims to provide.

THE VALUE OF UNIQALet’s compare the performance at the duty point indicated above of a UNIQA submersible pump with efficiency class Premium IE3 and high efficiency hydraulics (in blue) with that of an electric pump with standard motor and conventional hydraulics (in black).

Efficiency, performance and reliability

From words to deeds:high efficiency, not just in performance,but also in running costs.

The example highlights the fact that using a UNIQA pump with efficiency class PREMIUM IE3 (+6.2%) motor and high performance hydraulics (+33%) compared to a STANDARD pump, yields improved global system efficiency, at the duty point in question, of 6%, thus providing considerable cost savings.

THE EFFICIENCY ADVANTAGE OF A UNIQA PUMP WITH EFFICIENCY CLASS PREMIUM IE3 MOTOR AND HIGH PERFORMANCE HYDRAULICS CAN BE QUANTIFIED AT € 1,240.00/YEAR OF COST SAVINGS

[ŋ effi ciency]

PER CENT

UNIQA SUBMERSIBLE PUMP

STANDARD SUBMERSIBLE PUMP

P1

Energycost

P1

Energycost

€ /year

€ /year

TOTAL EFFICIENCY

PER CENT

PER CENT PER CENT

[ŋ effi ciency]

NOTE: All calculations are for example only. Energy costs can vary by supplier and consumption tariffs.

IMPROVEMENTMOTOR EFFICIENCY

MOTORCOMPARISON

IMPROVEMENTHYDRAULIC EFFICIENCY

HYDRAULIC COMPARISON (VORTEX)

STANDARD

66

2013 CATALOGUE - 50HZ

Cable glandThe cable gland can be sealed with extra resin on request in order to prevent any possible leakage into the lid even if the cable gland seal fails.

Motor compartmentOption to install one or more water/humidity sensors in the motor compartment.

Motor shaftThe whole range is equipped with AISI 431 stainless steel shafts. The NITRONIC 50 version is also available upon request (this type of stainless steel has higher chemical and mechanical resistance compared to AISI 316 and AISI 329).

Mechanical sealsTwo silicon carbide mechanical seals in the oil sump and V-rings. The oil can be be checked and changed even with the pump vertical, using plugs on the exterior of the mount.

BearingsOversized heavy-duty bearings designed for 50,000 hours of operation.

Flanges Various flange drilling are available, including ANSI and BS.

How it is made

77

80

90

100

2000 4000 6000

70

%

80

2000 4000 6000

70

2013 CATALOGUE - 50HZ

High-efficiency PREMIUM IE3 motors function, in according with NEMA A standard, and isulation in class H. Guaranteed S1 duty type in fluids at 60° C or higher temperature.

All hydraulic components are designed to provide highest effi ciency and best performance combined with wide free passage. The series is based on two different impeller types: high-effi ciency vortex or channel impellers. All models with open-channel impeller have an axial adjustment system that maintains the impeller’s balance for unchanged pump performance even at fi rst signs of wear. The Anti-Clogging-System (ACS) prevents blocking the impeller even in heavy-duty conditions.

Cooling system (PATENTED)

The motor is cooled down by a patented closed-circuit internal re-circulation system. This way, should any soiled liquid penetrate the oil chamber due to possible wear of the first mechanical seal, the fluid used in the process wouldn’t be affected.

Continuous duty is ensured even in dry and partially submerged working conditions.

Motor

Generally, since energy costs are higher than other expenses, continuous duty provides higher savings compared to a conventional system and the initial investment in a high efficiency systems is soon recouped, without considering the considerable advantages in terms of environmental footprint.

Operation (hours/year)2000 4000 6000

Purchase 3.8 1.9 1.3 Costs

(%)Maintenance 1.0 1.0 1.0

Energy 95.2 97.1 97.7

Hydraulics

8

KBS

DAC V DAC H

KBC KBS-H

2013 CATALOGUE - 50HZ

Installation types

Free installation (type S)

Installation with coupling device (type P)

Vertical installation (type T) and horizontal installation (type Z) in dry chamber

The pump may be installed in a dry chamber by using a cooling jacket.No external cooling fluid supply is required, since the motor is cooled by a PATENTED closed loop circuit with internal recirculation.In VERTICAL dry installations, the pump is secured to a curved base to which the suction flange is mounted.

In HORIZONTAL dry installations, the pump is secured to a steel frame and the suction pipe is connected directly to the pump’s suction flange.

The vertical or horizontal coupling device is fixed to the bottom of the tank and the pump is lowered in with the aid of two guide pipes fitted earlier, until the connection to the foot is completed. The delivery pipe is fixed to the coupling device discharge. This device makes routine checks, any maintenance work or replacement of the pump extremely easy, with no need to empty the tank.

The pump, mounted to its base, rests on the floor of the tank in the vertical position. It is connected to the system via a flanged pipe connected to its discharge port. The pump may also be connected to a flexible hose using a flanged bend union connected to the outlet port. This facilitates removing the pump from the tank and is recommended for temporary installations.

Undefined installation (type X)

The pump is not equipped for certain types of installation.This is the variant recommended for holding in stock.

9

Z U G V 080 B 18, 5/ 2 A W 194 X A21 3 4 5 6 7 8 9 10 11 12

2013 CATALOGUE - 50HZ

FeaturesZENIT UNIQA submersible electric pumps. Designed for heavy-duty professional applications, they are used in civil and industrial wastewater treatment plants, lifting sewage, pumping industrial sludges and rainwater containing solids, and recycling raw or activated sludges and biological liquids. ZENIT UNIQA series motors are designed with the aim of achieving the Premium (IE3) efficiency class according to EN 60034-30.The entire range is available in the “dry” version, which requires no external liquid inputs and allows the pump to operate conti-nually (S1 duty type) even if partially submerged or installed in a dry chamber. Non standard diameters are available for optimal performance on the specific duty point.

• The UNIQA series features a modular design in which the motor and hydraulics are perfectly coupled to each other, thus creating a robust and highly reliable assembly.

• Maximum operating temperatures to NEMA class A.• Motor case, impeller and hydraulics in cast iron/stainless steel.• High efficiency electric motors to class Premium (IE3).• Models available for 50 and 60Hz power supplies.• Thermal cutout integrated into stator to safeguard the motor even in heavy duty and

continuous service.• Long life lubricated bearings (50,000 hours).• AISI 431 motor shaft. Available in NITRONIC 50 on request.• Sensors for detecting water penetration into the mechanical seal oil sumps, motor

compartment and terminal box.• Two silicon carbide mechanical seals in large oil sump and V-rings.• Available with high performance channel or vortex impellers.• Hydraulics with discharge ports from DN65 to DN400.• Full free passage for vortex impeller models, min. 80mm for channel impeller models.• Patented closed jacket cooling system with internal recirculation.

Key to product code

1 P ro d u c t nam e Z U = Z e n i t U N I Q A

2 C o nstru c tio n m aterial G = C a st i r o n B = B r o n ze X = S t a i n l e ss st e e l

3 Ty p e o f im p eller O C = o p e n ch a n n e l C C = cl o se d ch a n n e l V = vo r t e x

4 D isc h arg e p o rt d iam eter in m m

5 H y d rau lic v ariant

6 P o w er in k W

7 Mo to r p o les

8 Mo to r v ariant

9 O p erating m o d e D = D r y W = W e t

10 N o m inal d iam eter o f im p eller ( in m m )

11 Ty p e o f installatio n

12 H o les f o r installatio n/ ac c esso ries

10

0

10

20

30

40

50

60

70

80

1 100

H [m

]

Q [ l/ s]

90

100

110

10 100050 5005

2013 CATALOGUE - 50HZ

Operating ranges

Construction materialsDescription Standard Optional

Motor case EN-GJL 250 -

Shaft 1.4057 (AISI 431) 1.4461 (AISI 329)-1.4542 (AISI 630) / NITRONIC 50

Hydraulic parts EN-GJL 250 1.4401 (AISI 316) / 1.4460 (AISI 329 Duplex)

Cooling jacket AISI 304 -

Gaskets NBR VITON

Screws A2-70 Stainless steel A4-80

Impeller EN-GJL 250 1.4401 (AISI 316) / 1.4460 (AISI 329 Duplex) / Br-Al

Lifting handle 1.4401 (AISI 316) -

Overview of operating ranges

Standard equipment and optionsDescription Standard Optional

Voltage 400 V 230, 500, 230/400, 440, 500/866 V

Power voltage tolerancemax ± 10% (S3 duty type)

-max ± 5% (S1 duty type)

Efficiency class IE3 - Premium Efficiency IE2 - High Efficiency

Power supply 3~ 50Hz VFD - 60Hz

Motor insulation class H -

Start Y Δ Direct, soft-start

Max. ambient temperature 40° C 60° C

Cable H07RN-F NSSHÖU- O/J, EMC

Cable length 10 mt 20 - 30 - 40 - 50 mt

Painting Epoxy bicomponent (120 micron) Epoxy bicomponent (400 micron)

Mechanical seals N.2 in silicon carbide (SiC/SiC) in oil chamber -

Thermal sensors Bimetallic thermal sensors (150°C) PTC/PT100 Thermistor

Installation types Submersed Dry

Probe water in

oil chamber/motor case YES -

oil chamber NO YES

motor case NO YES

motor cover case NO YES

Zinc anodes NO YES

Vibrations sensors (bearings) NO YES (see the technical specifications)

Thermal sensors (bearings) NO PTC/PTC100 (see the technical specifications)

ATEX certification NO YES

11

ZUG OC

100A 24

100E 26

150A 28

150D 30

200A 32

200C-4p 34

200C-6p 36

250B 38

250C 40

300B 42

300C 44

ZUG V

065A 12

080A 14

080B 16

100A 18

100B 20

150A 22

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505

H [m

]

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505

100A

300C 300B

250B

100E

150D

H [m

]

200C - 4p

200C - 6p

150A 200A250C

150A0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

080B

080A

100A

100B

H [m

]

065A

ηHydmax=

ηHydmax=

2013 CATALOGUE - 50HZ

ZUG V (vortex)

ZUG OC (channels)

Currently available operating ranges

Currently available operating ranges (VORTEX)

Currently available operating ranges (CHANNELS)

Vortex impeller Power da 4 kW a 37 kWDischarge from DN65 to DN150 Poles 2 - 4

Channles impeller Power from 4 kW to 185 kWDischarge from DN100 to DN300 Poles 4 - 6

page

page

12

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

065A

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100

0

5

10

15

20

25

30

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

25 75

125

3030

4343

2020

35354040

4040

3535

3030

2020

13514 5

45.345.3

4343

P2 [k

W]

Q [ l/ s]

Q [ m 3/ h ]

0

2

4

6

8

10

12

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

0 50 10025 75

125

135

14 5

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V 065A

4/2 AW 400 3 Y Δ 7.7 4.5 4.0 88.2

5.5/2 AW 400 3 Y Δ 10.2 6.1 5.5 89.2

7.5/2 AW 400 3 Y Δ 14.1 8.3 7.5 90.2

9/2 AW 400 3 Y Δ 16.5 9.94 9.0 90.6

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN65

Free passage 65 mm

Power 4 ÷ 9 kW

Poles 2

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Performances

Motor data

W: WET version (submerged operation - S1 duty type)

Product image is illustrative. Zenit reserves the right to modify the product without advance notifi cation.

Iso-effi ciency graphs (%)

Maximum effi ciency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Hydraulics Motor Phases

ZUG V 065A - 2 poles

45.3

13

F

E

D

C

G

H

L

AB

E

D

C

H V

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY

ZUG V 065A 4/2 AW 325 140 815 - 70 65 285 4x18 145 90 116 -

ZUG V 065A 5.5/2 AW 325 140 815 - 70 65 285 4x18 145 90 119 -

ZUG V 065A 7.5/2 AW 325 140 915 - 70 65 285 4x18 145 90 132 -

ZUG V 065A 9/2 AW 325 140 915 - 70 65 285 4x18 145 90 136 -

WETA mm B mm C mm

ZUG V 065A 4/2 A 915 535 560 H

ZUG V 065A 5.5/2 A 915 535 560 H

ZUG V 065A 7.5/2 A 1000 535 560 H

ZUG V 065A 9/2 A 1000 535 560 H

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Overall dimensions and weight

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Packaging dimensions

Available drilling variants

Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

14

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

080A

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150

0

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40 45

2020

3535

4040

4040

3535

2020

3030

3030

13512515 514 5

4141

P2 [k

W]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150

0

2

4

6

8

10

12

0 5 10 15 20 25 30 35 40 45

125

14 5

15 5

135

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V 080A

4/2 AW 400 3 Y Δ 7.7 4.5 4.0 88.2

5.5/2 AW 400 3 Y Δ 10.2 6.1 5.5 89.2

7.5/2 AW 400 3 Y Δ 14.1 8.3 7.5 90.2

9/2 AW 400 3 Y Δ 16.5 9.94 9.0 90.6

11/2 AW 400 3 Y Δ 20.0 12.1 11.0 91.2

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN80

Free passage 80 mm

Power 4 ÷ 11 kW

Poles 2

Performances

Motor data

Product image is illustrative. Zenit reserves the right to modify the product without advance notifi cation.

Iso-effi ciency graphs (%)

Maximum effi ciency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

ZUG V 080A - 2 poles

W: WET version (submerged operation - S1 duty type)

41

15

F

E

D

C

GH

L

AB

E

D

C

L 1

H V

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L° L1°Kg

WET DRY WET DRY

ZUG V 080A 4/2 AW 330 140 855 - 90 80 285 8x17.5 160 45 90 122 -

ZUG V 080A 5.5/2 AW 330 140 855 - 90 80 285 8x17.5 160 45 90 125 -

ZUG V 080A 7.5/2 AW 330 140 955 - 90 80 285 8x17.5 160 45 90 138 -

ZUG V 080A 9/2 AW 330 140 955 - 90 80 285 8x17.5 160 45 90 142 -

ZUG V 080A 11/2 AW 330 140 955 - 90 80 285 8x17.5 160 45 90 146 -

WETA mm B mm C mm

ZUG V 080A 4/2 A 915 535 560 H

ZUG V 080A 5.5/2 A 915 535 560 H

ZUG V 080A 7.5/2 A 1000 535 560 H

ZUG V 080A 9/2 A 1000 535 560 H

ZUG V 080A 11/2 A 1000 535 560 H

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Overall dimensions and weight

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Packaging dimensions

Available drilling variants

Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

16

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

080B

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150

0

10

20

30

40

50

0 5 10 15 20 25 30 35 40 45

3535

18 5

170

20203030

404042.542.5

4545

19 4

4040

3030

2020

4545

42.542.5

3535

45.545.5

15 5

P2 [k

W]

0

5

10

15

20

25

0 5 10 15 20 25 30 35 40 45 Q [ l/ s]

Q [ m 3/ h ]0 50 100 150

18 5

15 5

170

19 4

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V 080B

7.5/2 AW (D) 400 3 Y Δ 14.1 8.3 7.5 90.2

9/2 AW (D) 400 3 Y Δ 16.5 9.94 9.0 90.6

11/2 AW (D) 400 3 Y Δ 20.0 12.1 11.0 91.2

15/2 AW (D) 400 3 Y Δ 26.8 16.3 15.0 91.9

18.5/2 AW (D) 400 3 Y Δ 33.1 20.0 18.5 92.4

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN80

Free passage 80 mm

Power 7.5 ÷ 18.5kW

Poles 2

Motor data

Performances

Iso-effi ciency graphs (%)

Maximum effi ciency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notifi cation.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG V 080B - 2 poles

45.5

17

F

E

D

C

GH

L

AB

E

D

C

L 1

H V

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L° L1°Kg

WET DRY WET DRY (*)ZUG V 080B 7.5/2 AW (D) 405 170 955 1030 90 80 325 8x17.5 160 45 90 169 253

ZUG V 080B 9/2 AW (D) 405 170 955 1030 90 80 325 8x17.5 160 45 90 173 257

ZUG V 080B 11/2 AW (D) 405 170 955 1030 90 80 325 8x17.5 160 45 90 177 261

ZUG V 080B 15/2 AW (D) 415 180 1120 1120 90 80 365 8x17.5 160 45 90 232 266

ZUG V 080B 18.5/2 AW (D) 415 180 1120 1120 90 80 365 8x17.5 160 45 90 241 275

WET DRYA mm B mm C mm A mm B mm C mm

ZUG V 080B 7.5/2 A 1000 535 560 H 770 620 1400 V

ZUG V 080B 9/2 A 1000 535 560 H 770 620 1400 V

ZUG V 080B 11/2 A 1000 535 560 H 770 620 1400 V

ZUG V 080B 15/2 A 1270 725 670 H 770 620 1400 V

ZUG V 080B 18.5/2 A 1270 725 670 H 770 620 1400 V

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

18

P2 [k

W]

Q [ l/ s]

Q [ m 3/ h ]

0

5

10

15

20

25

30

35

40

45

50

0 10 20 30 40 50 60 70 80

0 50 100 150 200 250

230 220 210200

170

15 0

16 0

24 0

19 0 18 0

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200

0

10

20

30

40

50

60

70

80

0 10 20 30 40 50 60 70 80

250

24 0

230

200

17016 015 0

30302020

4040

220

210

18 0

5050

4545

4040

3030

2020

4545

5050

19 0

5151

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

100A

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V100A

15/2 AW (D) 400 3 Y Δ 26.8 16.3 15.0 91.9

18.5/2 AW (D) 400 3 Y Δ 33.1 20.0 18.5 92.4

22/2 AW (D) 400 3 Y Δ 39.3 23.7 22.0 92.8

30/2 AW (D) 400 3 Y Δ 53.0 32.15 30.0 93.3

37/2 HW (D) 400 3 Y Δ 64.0 40.0 37.0 92.5

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN100

Free passage 100 mm

Power 15 ÷ 37 kW

Poles 2

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG V 100A - 2 poles

51

19

F

E

D

C

G

H

L

AB

E

D

C

H V

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG V 100A 15/2 AW (D) 500 195 1170 1170 110 100 375 8x17.5 180 45 233 267

ZUG V 100A 18.5/2 AW (D) 500 195 1170 1170 110 100 375 8x17.5 180 45 242 276

ZUG V 100A 22/2 AW (D) 505 200 1220 1220 110 100 405 8x17.5 180 45 303 350

ZUG V 100A 30/2 AW (D) 505 200 1220 1220 110 100 405 8x17.5 180 45 314 361

ZUG V 100A 37/2 HW (D) 505 200 1220 1220 110 100 405 8x17.5 180 45 314 361

WET DRYA mm B mm C mm A mm B mm C mm

ZUG V 100A 15/2 A 1270 725 670 V 770 620 1400 V

ZUG V 100A 18.5/2 A 1270 725 670 V 770 620 1400 V

ZUG V 100A 22/2 A 1270 725 670 V 770 620 1400 V

ZUG V 100A 30/2 A 1270 725 670 V 770 620 1400 V

ZUG V 100A 37/2 H 1270 725 670 V 770 620 1400 V

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

20

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

100B

P2 [k

W]

Q [ l/ s]

Q [ m 3/ h ]

0

2

4

6

8

10

12

14

16

0 10 20 30 40 50 60 70 80

0 50 100 150 200 250

16 5

210

19 0

235

25 5

26 6

24 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]

0

5

10

15

20

25

0 10 20 30 40 50 60 70 80

0 50 100 150 200 250

30304040

5050

25 5210

5252

5252

5050

4545

3030

4040

2020

4545

235

26 6

24 5

5353

19 016 5

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V100B

4/4 AW (D) 400 3 Y Δ 8.45 4.5 4.0 88.7

5.5/4 AW (D) 400 3 Y Δ 11.65 6.14 5.5 89.6

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

9/4 AW (D) 400 3 Y Δ 17.2 9.9 9.0 90.9

11/4 AW (D) 400 3 Y Δ 21.2 12.0 11.0 91.4

15/4 AW (D) 400 3 Y Δ 28.5 16.3 15.0 92.2

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN100

Free passage 100 mm

Power 4 ÷ 15 kW

Poles 4

Motor data

Performances

Iso-effi ciency graphs (%)

Maximum effi ciency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notifi cation.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG V 100B - 4 poles

53

21

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG V 100B 4/4 AW (D) 500 195 1000 1080 110 100 375 8x17.5 180 45 172 241

ZUG V 100B 5.5/4 AW (D) 500 195 1000 1080 110 100 375 8x17.5 180 45 176 245

ZUG V 100B 7.5/4 AW (D) 500 195 1080 1080 110 100 375 8x17.5 180 45 215 252

ZUG V 100B 9/4 AW (D) 500 195 1170 1170 110 100 375 8x17.5 180 45 238 271

ZUG V 100B 11/4 AW (D) 505 200 1220 1220 110 100 405 8x17.5 180 45 288 334

ZUG V 100B 15/4 AW (D) 505 200 1220 1220 110 100 405 8x17.5 180 45 301 348

WET DRYA mm B mm C mm A mm B mm C mm

ZUG V 100B 4/4 A 1270 725 670 H 770 620 1400 V

ZUG V 100B 5.5/4 A 1270 725 670 H 770 620 1400 V

ZUG V 100B 7.5/4 A 1270 725 670 H 770 620 1400 V

ZUG V 100B 9/4 A 1270 725 670 V 770 620 1400 V

ZUG V 100B 11/4 A 1270 725 670 V 770 620 1400 V

ZUG V 100B 15/4 A 1270 725 670 V 770 620 1400 V H V

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Packaging dimensions

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

22

H [m

]0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

5 50 500

150A

P2 [k

W]

Q [ m 3/ h ]0 50 100 150 200 250 300 350 400

Q [ l/ s]0

2

4

6

8

10

12

14

16

0 20 40 60 80 100 120

25 5

26 6

24 5235

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200 250 300 350 400

0

2

4

6

8

10

12

14

16

18

0 20 40 60 80 100 120

30302020

40404545

4848

4848

4545

4040

3030

2020

24 5 25 5 26 6235

50.150.1

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG V 150A

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

9/4 AW (D) 400 3 Y Δ 18.3 9.9 9.0 90.8

11/4 AW (D) 400 3 Y Δ 21.2 12.0 11.0 91.4

15/4 AW (D) 400 3 Y Δ 28.5 16.3 15.0 92.2

PUMPS WITH VORTEX IMPELLER 2013 CATALOGUE - 50HZ

Vortex impeller

Discharge DN150

Free passage 125 mm

Power 7.5 ÷ 15 kW

Poles 4

Motor data

Performances

Iso-effi ciency graphs (%)

Maximum effi ciency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notifi cation.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG V 150A - 4 poles

50.1

23

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG V 150A 7.5/4 AW (D) 555 210 1090 1090 150 150 400 8x22 240 45 235 272

ZUG V 150A 9/4 AW (D) 555 210 1180 1180 150 150 400 8x22 240 45 258 291

ZUG V 150A 11/4 AW (D) 555 210 1230 1230 150 150 400 8x22 240 45 308 354

ZUG V 150A 15/4 AW (D) 555 210 1230 1230 150 150 400 8x22 240 45 321 368

WET DRYA mm B mm C mm A mm B mm C mm

ZUG V 150A 7.5/4 A 1270 725 670 H 770 620 1400 V

ZUG V 150A 9/4 A 1270 725 670 H 770 620 1400 V

ZUG V 150A 11/4 A 1270 725 670 H 770 620 1400 V

ZUG V 150A 15/4 A 1270 725 670 H 770 620 1400 V

H V

PUMPS WITH VORTEX IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Packaging dimensions

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

24

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

100A

P2 [k

W]

0

2

4

6

8

10

12

14

16

18

20

0 10 20 30 40 50 60 70 80 90 100 Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200 250 300 350

235

230

26 0

270

24 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200

0

5

10

15

20

25

30

0 10 20 30 40 50 60 70 80 90 100

250 300 350

50506060

7070

23524 5

7070

6565

6060

4040

4040

2020

6565

5050

26 0

3030

270

7171

230

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 100A

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

9/4 AW (D) 400 3 Y Δ 17.2 9.9 9.0 90.9

11/4 AW (D) 400 3 Y Δ 21.2 12.0 11.0 91.4

15/4 AW (D) 400 3 Y Δ 28.5 16.3 15.0 92.2

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN100

Free passage 80 mm

Power 7.5 ÷ 15 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 100A - 4 poles

71

25

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 100A 7.5/4 AW (D) 550 210 1025 1025 125 100 415 8x17.5 180 45 240 275

ZUG OC 100A 9/4 AW (D) 550 210 1120 1120 125 100 415 8x17.5 180 45 261 294

ZUG OC 100A 11/4 AW (D) 550 210 1170 1170 125 100 420 8x17.5 180 45 314 352

ZUG OC 100A 15/4 AW (D) 550 210 1170 1170 125 100 420 8x17.5 180 45 327 375

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 100A 7.5/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 100A 9/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 100A 11/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 100A 15/4 A 1270 725 670 H 770 620 1400 V H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

26

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505100E

H [m

]

P2 [k

W]

Q [ l/ s]0

1

2

3

4

5

6

7

8

9

10

0 10 20 30 40 50 60 70 80

Q [ m 3/ h ]0 50 100 150 200 250

210

220

222

221

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200 250

0

2

4

6

8

10

12

14

0 10 20 30 40 50 60 70 80

2020

5555

6060

222

210

5050

3030

220

5555

5050

4040

6060

4040

221

6363

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 100E

4/4 AW (D) 400 3 Y Δ 8.45 4.5 4.0 88.7

5.5/4 AW (D) 400 3 Y Δ 11.65 6.14 5.5 89.6

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN100

Free passage 80 mm

Power 4 ÷ 7.5 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 100E - 4 poles

63

27

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 100E 4/4 AW (D) 550 210 950 1025 125 100 415 8x17.5 180 45 190 259

ZUG OC 100E 5.5/4 AW (D) 550 210 950 1025 125 100 415 8x17.5 180 45 194 263

ZUG OC 100E 7.5/4 AW (D) 550 210 1025 1025 125 100 415 8x17.5 180 45 233 266

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 100E 4/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 100E 5.5/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 100E 7.5/4 A 1270 725 670 H 770 620 1400 VH V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

28

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

150A

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]0

2

4

6

8

10

12

14

16

18

0 20 40 60 80 100 120 140

0 100 200 300 400 500

27026 0

235230

24 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 100 200 300 400

0

5

10

15

20

25

30

0 20 40 60 80 100 120 140

500

270

26 0

3030

5050

6565

4040

230

6060

235

6767

67676565

6060

5050

3030

24 5

4040

2020

7070

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 150A

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

9/4 AW (D) 400 3 Y Δ 17.2 9.9 9.0 90.9

11/4 AW (D) 400 3 Y Δ 21.2 12.0 11.0 91.4

15/4 AW (D) 400 3 Y Δ 28.5 16.3 15.0 92.2

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN150

Free passage 80 mm

Power 7.5 ÷ 15 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 150A - 4 poles

70

29

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 150A 7.5/4 AW (D) 615 225 1030 1030 130 150 450 8x22 240 45 258 295

ZUG OC 150A 9/4 AW (D) 615 225 1120 1120 130 150 450 8x22 240 45 281 314

ZUG OC 150A 11/4 AW (D) 615 225 1170 1170 130 150 450 8x22 240 45 331 377

ZUG OC 150A 15/4 AW (D) 615 225 1170 1170 130 150 450 8x22 240 45 344 391

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 150A 7.5/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 150A 9/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 150A 11/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 150A 15/4 A 1270 725 670 H 770 620 1400 V H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

30

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

150D

P2 [k

W]

Q [ m 3/ h ]

0

2

4

6

8

10

0 20 40 60 80 100 120

0 50 100 150 200 250 300 350 400

Q [ l/ s]

222

220

210

221

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 50 100 150 200 250

0

2

4

6

8

10

12

14

0 20 40 60 80 100 120

300 350 400

63.563.5

6060

30304040

50505555

6060

55555050

40403030

2020

210 220 222221

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 150D

4/4 AW (D) 400 3 Y Δ 8.45 4.5 4.0 88.7

5.5/4 AW (D) 400 3 Y Δ 11.65 6.14 5.5 89.6

7.5/4 AW (D) 400 3 Y Δ 14.5 8.3 7.5 90.4

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN150

Free passage 80 mm

Power 4 ÷ 7.5 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 150D - 4 poles

63.5

31

F

E

D

C

G

HL

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 150D 4/4 AW (D) 615 225 955 1030 130 150 450 8x22 240 45 211 280

ZUG OC 150D 5.5/4 AW (D) 615 225 955 1030 130 150 450 8x22 240 45 215 284

ZUG OC 150D 7.5/4 AW (D) 615 225 1030 1030 130 150 450 8x22 240 45 254 291

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 150D 4/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 150D 5.5/4 A 1270 725 670 H 770 620 1400 V

ZUG OC 150D 7.5/4 A 1270 725 670 H 770 620 1400 V H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

32

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

200A

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 200A

7.5/6 AW (D) 400 3 Y Δ 16.2 8.4 7.5 89.1

9/6 AW (D) 400 3 Y Δ 19.8 10.0 9.0 89.7

11/6 AW (D) 400 3 Y Δ 22.7 12.2 11.0 90.3

13/6 HW (D) 400 3 Y Δ 25.9 14.6 13.0 89.2

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]0

2

4

6

8

10

12

14

0 20 40 60 80 100 120 140 160 180 200

0 100 200 300 400 500 600 700

275270

300

325

334

28 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 100 200 300 400

0

2

4

6

8

10

12

14

16

18

20

0 20 40 60 80 100 120 140 160 180 200

500 600 700

5050

3030

5050

7575

20204040

6060

7070

7070

6060

7575

4040

8080

270 275334300 32528 5

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN200

Free passage 100x70 mm

Power 7.5 ÷ 13 kW

Poles 6

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 200A - 6 poles

80

33

F

E

D

C

G

HL

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 200A 7.5/6 AW (D) 695 275 1265 1265 205 200 540 8x22 295 45 364 411

ZUG OC 200A 9/6 AW (D) 695 275 1265 1265 205 200 540 8x22 295 45 373 420

ZUG OC 200A 11/6 AW (D) 695 275 1265 1265 205 200 540 8x22 295 45 382 429

ZUG OC 200A 13/6 HW (D) 695 275 1265 1265 205 200 540 8x22 295 45 382 429

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 200A 7.5/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 200A 9/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 200A 11/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 200A 13/6 H 1170 975 1505 V 1170 975 1505 V H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

EN 1

092-

2 Ta

b.8

(PN

10-1

6)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

34

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

200C - 4p

P2 [k

W]

0

20

40

60

80

100

120

140

160

180

200

0 50 100 150 200 250 300 350 400 Q [ l/ s]

Q [ m 3/ h ]0 200 400 600 800 1000 1200 1400

4 5 5

4 204 304 4 0

4 6 5

4 8 04 9 0

39 54 05

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 200 400 600 800 1000 1200 1400

0

20

40

60

80

100

0 50 100 150 200 250 300 350 400

4 9 0

4 6 54 5 5

4 30

4 0539 5

4 8 0

4 20

4 4 0

3030

50506060

7070

4040

7575

7878

75757070

6060

7979

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 200C

90/4 AW (D) 400 3 Y Δ 160 94.5 90 95.2

110/4 AW (D) 400 3 Y Δ 198 115.3 110 95.4

132/4 AW (D) 400 3 Y Δ 238 138 132 95.6

160/4 AW (D) 400 3 Y Δ 299 167 160 95.8

185/4 HW 400 3 Y Δ 342 194.5 185 95.1

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN200

Free passage 100 mm

Power 90 ÷ 185 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

ZUG OC 200C - 4 poles

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

79

35

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 200C 90/4 AW (D) 1075 415 1870 1870 170 200 815 8x22 295 45 1530 1700

ZUG OC 200C 110/4 AW (D) 1075 415 1870 1870 170 200 815 8x22 295 45 1572 1759

ZUG OC 200C 132/4 AW (D) 1075 415 2060 2060 170 200 815 8x22 295 45 1730 1944

ZUG OC 200C 160/4 AW (D) 1075 415 2060 2060 170 200 815 8x22 295 45 1875 2090

ZUG OC 200C 185/4 HW 1075 415 2060 - 170 200 815 8x22 295 45 1880 -

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 200C 90/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 200C 110/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 200C 132/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 200C 160/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 200C 185/4 H 1630 1140 2520 V - - - - H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

36

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

200C - 6p

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]0

20

40

60

80

100

0 50 100 150 200 250 300 350 400

0 200 400 600 800 1000 1200 1400

5 20

4 8 0

5 10

4 9 0

H [m

]

Q [ l/ s]

Q [ m 3/ h ]

0

5

10

15

20

25

30

35

40

45

50

0 50 100 150 200 250 300 350 400

0 200 400 600 800 1000 1200 1400

30304040

75757070

60605050

7878

78787575

6060

5 20

4 8 04 9 0

5 105050

7070

8080

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 200C75/6 AW (D) 400 3 Y Δ 149 79.3 75 94.6

90/6 AW (D) 400 3 Y Δ 175.5 94.8 90 94.9

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN200

Free passage 100 mm

Power 75 - 90 kW

Poles 6

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

ZUG OC 200C - 6 poles

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

80

37

F

E

D

C

G

HL

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 200C 75/6 AW (D) 1075 415 1870 1870 170 200 815 8x22 295 45 1565 1735

ZUG OC 200C 90/6 AW (D) 1075 415 1870 1870 170 200 815 8x22 295 45 1595 1765

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 200C 75/6 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 200C 90/6 A 1630 1140 2225 V 1630 1140 2225 V

H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

38

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]

0 200 400 600 800 1000 1200 1400 1600 1800 2000

0

20

40

60

80

100

120

140

160

180

200

0 50 100 150 200 250 300 350 400 450 500 550 600

4 4 0

4 10

4 6 0

38 5

34 536 0

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 200 400 600 800 1000 1200 1400 1600 1800 2000

0

10

20

30

40

50

60

70

80

0 50 100 150 200 250 300 350 400 450 500 550 600

5050

8080

4 6 04 4 04 1038 536 0

3030 4040

6060

70707575

34 5

7070

8080

7575

81.281.2

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

250B

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 250B

90/4 AW (D) 400 3 Y Δ 160 94.5 90 95.2

110/4 AW (D) 400 3 Y Δ 198 115.3 110 95.4

132/4 AW (D) 400 3 Y Δ 238 138.0 132 95.6

160/4 AW (D) 400 3 Y Δ 299 167.0 160 95.8

185/4 HW 400 3 Y Δ 342 194.5 185 95.1

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN250

Free passage 110 mm

Power 90 ÷ 185 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 250B - 4 poles

81.2

39

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 250B 90/4 AW (D) 1055 440 1925 1925 205 250 825 12x22 350 30 1463 1650

ZUG OC 250B 110/4 AW (D) 1055 440 1925 1925 205 250 825 12x22 350 30 1504 1691

ZUG OC 250B 132/4 AW (D) 1055 440 2115 2115 205 250 825 12x22 350 30 1663 1877

ZUG OC 250B 160/4 AW (D) 1055 440 2115 2115 205 250 825 12x22 350 30 1814 2028

ZUG OC 250B 185/4 HW 1055 440 2115 - 205 250 825 12x22 350 30 1814 -

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 250B 90/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 250B 110/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 250B 132/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 250B 160/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 250B 185/4 H 1630 1140 2520 V - - - - H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

40

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

250C

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]

0 100 200 300 400 500 600 700

0

2

4

6

8

10

12

14

0 20 40 60 80 100 120 140 160 180 200

325

334

300

275270

28 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 100 200 300 400 500 600 700

0

2

4

6

8

10

12

14

16

18

0 20 40 60 80 100 120 140 160 180 200

8383

75757070

50506060

325 33430028 5

3030

5050

75758080

7070

4040

8383

8080

6060

8585

275270

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 250C

7.5/6 AW (D) 400 3 Y Δ 16.2 8.4 7.5 89.1

9/6 AW (D) 400 3 Y Δ 19.8 10.0 9.0 89.7

11/6 AW (D) 400 3 Y Δ 22.7 12.2 11.0 90.3

13/6 AW (D) 400 3 Y Δ 25.9 14.6 13.0 89.2

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN250

Free passage 100x70 mm

Power 7.5 ÷ 13 kW

Poles 6

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 250C - 6 poles

85

41

F

E

D

C

G

H

L

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 250C 7.5/6 AW (D) 810 335 1265 1265 205 250 610 12x22 350 30 386 433

ZUG OC 250C 9/6 AW (D) 810 335 1265 1265 205 250 610 12x22 350 30 395 442

ZUG OC 250C 11/6 AW (D) 810 335 1265 1265 205 250 610 12x22 350 30 404 451

ZUG OC 250C 13/6 AW (D) 810 335 1265 1265 205 250 610 12x22 350 30 404 451

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 250C 7.5/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 250C 9/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 250C 11/6 A 1170 975 1505 V 1170 975 1505 V

ZUG OC 250C 13/6 A 1170 975 1505 V 1170 975 1505 V

H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

42

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

300B

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]0

20

40

60

80

100

120

140

160

180

200

0 100 200 300 400 500 600 700

0 500 1000 1500 2000 2500

4 6 0

36 0

4 4 0

4 10

34 5

38 5

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 500 1000 1500 2000

0

10

20

30

40

50

60

70

0 100 200 300 400 500 600 700

2500

4040

8282

4 6 0

36 04 4 04 10

34 5

7575

8080

3030

6060

7070

75757070

6060

8080

5050

38 5

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 300B

90/4 AW (D) 400 3 Y Δ 160 94.5 90 95.2

110/4 AW (D) 400 3 Y Δ 198 115.3 110 95.4

132/4 AW (D) 400 3 Y Δ 238 138.0 132 95.6

160/4 AW (D) 400 3 Y Δ 299 167.0 160 95.8

185/4 HW 400 3 Y Δ 342 194.5 185 95.1

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN300

Free passage 110 mm

Power 90 ÷ 185 kW

Poles 4

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Hydraulics Motor Phases

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 300B - 4 poles

82

43

F

E

D

C

G

HL

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 300B 90/4 AW (D) 1170 490 1975 1975 250 300 920 12x22 400 30 1660 1847

ZUG OC 300B 110/4 AW (D) 1170 490 1975 1975 250 300 920 12x22 400 30 1701 1889

ZUG OC 300B 132/4 AW (D) 1170 490 2165 2165 250 300 920 12x22 400 30 1860 2074

ZUG OC 300B 160/4 AW (D) 1170 490 2165 2165 250 300 920 12x22 400 30 2011 2225

ZUG OC 300B 185/4 HW 1170 490 2165 - 250 300 920 12x22 400 30 2011 -

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 300B 90/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 300B 110/4 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 300B 132/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 300B 160/4 A 1630 1140 2520 V 1630 1140 2520 V

ZUG OC 300B 185/4 H 1630 1140 2520 V - - - - H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Type Type

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

DRY WET

44

0

10

20

30

40

50

60

70

80

90

100

1 100Q [ l/ s]

10

110

500505H

[m]

300C

P2 [k

W]

Q [ m 3/ h ]

Q [ l/ s]0

10

20

30

40

50

60

70

80

90

100

0 50 100 150 200 250 300 350 400 450 500 550 600

0 200 400 600 800 1000 1200 1400 1600 1800 2000

4 6 0

4 4 5

4 77

H [m

]

Q [ l/ s]

Q [ m 3/ h ]0 200 400

0

5

10

15

20

25

30

35

40

0 50 100 150 200 250 300 350 400 450 500 550 600

600 800 1000 1200 1400 1600 1800 2000

30304040 5050

4 774 6 0

4 4 5

7575

8484

60607070

8080 8282

82828080

7070

5050

7575

6060

4040

84.284.2

ηHydmax=

V Start A P1(kW)

P2(kW) η mot.

ZUG OC 300C75/6 AW (D) 400 3 Y Δ 149 79.3 75 94.6

90/6 AW (D) 400 3 Y Δ 175.5 94.8 90 94.9

PUMPS WITH OPEN CHANNELS IMPELLER 2013 CATALOGUE - 50HZ

Open channels Impeller

Discharge DN300

Free passage 150x110 mm

Power 75-90 kW

Poles 6

Motor data

Performances

Iso-efficiency graphs (%)

Maximum efficiency (%)

Cha

ract

eris

tic c

urve

s ac

cord

ing

to U

NI E

N IS

O 9

906

Hydraulics Motor Phases

The documentation for each model as well as the technical data sheets and user manuals are available at www.zenit.com or from Cu-stomer Service.

Product image is illustrative. Zenit reserves the right to modify the product without advance notification.

W: WET version (submerged operation - S1 duty type)D: DRY version (dry operation - S1 duty type)

ZUG OC 300C - 6 poles

84.2

45

F

E

D

C

G

HL

AB

E

D

C

Amm

Bmm

C mm Dmm

Emm

Fmm

Gmm

Hmm

L°Kg

WET DRY WET DRY (*)

ZUG OC 300C 75/6 AW (D) 1170 490 1975 1975 250 300 920 12x22 400 30 1600 1787

ZUG OC 300C 90/6 AW (D) 1170 490 1975 1975 250 300 920 12x22 400 30 1640 1827

WET DRYA mm B mm C mm A mm B mm C mm

ZUG OC 300C 75/6 A 1630 1140 2225 V 1630 1140 2225 V

ZUG OC 300C 90/6 A 1630 1140 2225 V 1630 1140 2225 V

H V

PUMPS WITH OPEN CHANNELS IMPELLER2013 CATALOGUE - 50HZ

Available drilling variants

Overall dimensions and weight

Packaging dimensions

(*) Weight for the DRY version includes cooling fluid

The

prod

uct’s

out

line

is p

urel

y ill

ustr

ativ

e

Inst

alla

tion

type

Dril

ling

varia

nt

Acc

esso

ry r

equi

red

Discharge flange

Suction flange

KBS

dril

ling

KBS

-H d

rillin

g

FLX

dril

ling

EN 1

092-

2 Ta

b.8

(PN

10)

EN 1

092-

2 Ta

b.8

(PN

10)

Type Type

DRY WET

P

PADAC V

●PF ● ●PA

DAC H●

PF ● ●

SSA

KBS● ●

SF ● ● ●

TTA KBC ● ●TJ KBC + KBS ● ● ●

ZZA KBS-H ● ● ●ZJ KBS-H ● ●

X

XA DAC-KBC ● ●XB DAC-KBC-KBS ● ● ●XC DAC-KBC-KBS-KBS-H ● ● ● ●XE DAC-KBC-KBS-FLX ● ● ● ●

46

3

1

4

2

7

8

5

6

9

10

11

12

13

14

15

16

17

19

18

20

21

22

2 0m

Zenit Italia s.r.l.via dell’Industria, 11 I-41018 S.Cesario s.P. (MO)

S1

K g

EN 60034-1

www.zenit.com

Y.TYPES.N.VERS

MADE IN ITALY

I.CL.P2 k W %Tam b m ax ° Ccos φV V Hz

rpmA A

IP mHm axØ im p . mHm in

l/ sQm in l/ sQm ax

3~

η m ot

0

10

20

30

40

50

60

70

80

1 100

H [m

]

Q [ l/ s]

90

100

110

10 100050 5005

Zenit Italia s.r.l.via dell’Industria, 11 I-41018 S.Cesario s.P. (MO)www.zenit.com

II 2GD Ex db k c IIB T4 Ex tb IIIC T 135°C

EUM1 13 ATEX 1027

MADE IN ITALY

HIGH EFFICIENCYPUMPS

2013 CATALOGUE - 50HZ

Product name

Year of manufacture

Version

Serial number

Voltage and current (delta connection)

Voltage and current (Y connection)

Frequency

Power factor

Rpm

Maximum ambient temperature

Motor power output

Motor efficiency

Motor insulation class

Motor reference standards

Duty type

Casing protection rating

Nominal diameter of impeller

Maximum and minimum head

Minimum and maximum flow-rate

Maximum immersion depth

Weight

-EX mark

Nameplate

Operating ranges scheduled for issue in 2014

17 18

3

1

4

2

7 85 6

9 10

11 12 13 14 15

161920

21

22

NEW HIGHPERFORMANCE

SERIES

Cod. 29040060900400000Rev. 4 - 31/10/13

www.zenit.com