Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking...

27
Study of the Spatial Resolution and Muon Tomographic Imaging Proper ties of Glass RPCs Qite Li Peking University

Transcript of Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking...

Page 1: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Study of the Spatial Resolution and Muon Tomographic Imaging Properties of

Glass RPCs

Qite Li

Peking University

Page 2: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Knowledge is PowerSir Francis Bacon (1561-1626)

Page 3: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Nuclear Knowledge can be the Power of

• Peace• Happiness

• Fear• Frustration

Page 4: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

●Uranium 90% (HEU)●Pu-239 93% (WGPu)

●26 kg HEU / 5kg WGPu ●11 cm / 6 cm box

Page 5: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.
Page 6: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Muon Tomography(MT)

2.3mrad 10mrad 20mrad ~1.1°

~GeV Muon 1/cm2/min

water Fe W10cm

Page 7: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

MT Station Examples

Los Alamos (2003): Drift Tubes

Science and Global Security 16 (2008)37–53

INFN : CMS Muon Barrel Chambers

Nucl. Inst. and Meth. A 604 (2009) 738-746.

FIT : Triple GEMs

Nucl. Inst. and Meth. A 652 (2012) 16-20

Page 8: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Requirements of Detectors for MT

• Large Area (~1m2)• High Detction Efficiency (>90%)• High Spatial Resolution (<1mm)

• Cost-effective

Page 9: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

RPC

• Resistive Plate Chamber– R. Santonico(in 1980s)

• Large Area• Good Time Solution~1ns

• Acceptable Spatial Resolution– ~1cm

CMS Muon Trigger RPCs by PKU (200

2)

Page 10: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

-HV

HV Graphite

Resistive Plate

Working Gas

Resistive Plate

Gruand GraphiteReadout Strips

RPC Brief View

Page 11: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Combination of RPC & Delay-line Readout

90% F134a+9% C4H10+1% SF6

50ml/Min

Page 12: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

• Avalenche Signal

General Properties: Signals

• Avalenche +Streamer Signal

Page 13: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

General Properties: Detection Efficiency

Page 14: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

-HV

Page 15: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Streamer ProfileSigma 7.4±0.2mm

Avalanche ProfileSigma 2.2±0.1mm

Simulation ProfileSigma 2.40mm

Page 16: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Spatial Resolution Measurement

• Residual Method

• ΔX=X2-(X1+X3)/2

Page 17: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Spatial Resolution of Glass RPCs

mmFWHM

mmmm

XXXf

xx

x

xxxx

90.035.2

384.0470.0816.03

2

2

3)2

1()

2

1(

2/)(

223

221

222

2

312

Page 18: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Uniformity

-50mm~-25mm

Res=0.99 mm

-25mm~0mm

Res=0.89 mm

0mm~25mm

Res=0.82 mm

25mm~50mm

Res=0.94 mm

Page 19: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

X Y and T readout in ONE RPC

Page 20: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

X axis

0.79 mm (FWHM)

for one RPC

Y axis

1.97 mm (FWHM)

for one RPC

Preliminary

Preliminary

Page 21: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

MT Station with three 2D-Glass RPCs12+2 channels

1P

2P

RPC 1

RPC 2

RPC 33P

Material

Page 22: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Imaging Result: Empty target

• Empty target

• Mean angle ~15 mrad– Position/Alignment err

or • ~8 mrad

– RPC box, framework• ~10 mrad

Preliminary

Page 23: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Imaging Result: Pb brick 1

• Pb brick 1• 15cm*5.5cm*3.5cm

Preliminary

Page 24: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Imaging Result: Pb brick 2

• Pb brick 2• 24cm*7cm*6cm

Preliminary

Page 25: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Conclusions

• Glass RPCs with LC Delay-line Readout– Simple structrue, stable performance– Efficiency 95~98%– Charge profile measurement

• <1mm(FWHM) in avalenche mode

– Ideal detectors for MT

• MT Station using three 2D-Glass RPCs– Preliminary Test (detection area: 20cm*20cm)– Sensitive to ~cm Pb

Page 26: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

MT station with 4 RPCs 3D ImagingComing Soon

Page 27: Study of the Spatial Resolution and Muon Tomographic Imaging Properties of Glass RPCs Qite Li Peking University.

Thank You!

Email: [email protected] Gmail: [email protected]

Supervisor: Prof. Yanlin YeEmail: [email protected]

Peking University, China