Study of the MPPC for the GLD Calorimeter readout
description
Transcript of Study of the MPPC for the GLD Calorimeter readout
![Page 1: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/1.jpg)
Study of the MPPC for the GLD Calorimeter readout
Satoru Uozumi (Shinshu University)Feb 3-8 2007 LCWS @ Beijing
• Introduction• Basic performances• Future improvements• Summary
![Page 2: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/2.jpg)
EM-Scintillator-layer model
TT 10Aug05
particles
T-Layer
X-Layer
Z-Layer
4cmx4cmx2mm
1cmx4cmx2mm
1cmx4cmx2mm
MPC R/O with WLSF
MPC R/O with WLSF
MPC R/O with WLSF
absorber plate
• Sampling calorimeter with Pb/W - scintillator sandwich structure with WLSF readout
• Particle Flow Algorithm (PFA) needs particle separation in the calorimeter
• Fine granularity with strip/tile scintillator
• Huge number of readout channels– ~10M (ECAL) + 4M (HCAL) !– 10K for muon detector
• Used inside 3 Tesla solenoid
Need a new photon sensorwhich is compact and low-cost, and has enough performance.
The GLD Calorimeter
![Page 3: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/3.jpg)
~ 1 mm
Depletion region ~ 2 m Substrate
substrate p+
p-
Guard ring n-
Alconductor
p+ n+
Si Resistor Vbias
The Multi Pixel Photon Counter (MPPC)- A novel semiconductor photon sensor -
1600 pixel MPPC
![Page 4: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/4.jpg)
Excellent photon counting ability0,1,2,3,4,5,6,7, . . . Photoelectrons !
1 photoelectron
2 photoelectrons
4 mm1.3 mm
Side
3 mm
Front
![Page 5: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/5.jpg)
Photomultiplier MPPCGain ~106 105~106
Photon Detection Eff. 0.1 ~ 0.2 ~0.2 for 1600 pix. MPPCResponse fast fast
Photon counting Yes GreatBias voltage ~ 1000 V ~ 70 V
Size Small CompactB field Sensitive InsensitiveCost Very expensive ! Not very expensive
Dynamic range Good Determined by # of pixelsLong-term Stability Good Unknown
Robustness decent Unknown, presumably good
Noise (fake signal by thermions)
Quiet Noisy (order of 100 kHz)
The MPPC has lots of advantages
The MPPC is a promising photon sensor, and feasible for the GLD Calorimeter readout !
![Page 6: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/6.jpg)
Basic performance
• Gain and its variation over 400 MPPCs• Dark Noise Rate• Cross-talk• Photon Detection Efficiency
![Page 7: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/7.jpg)
•30oC•25oC•20oC•15oC•10oC•0oC•-20oC
– C … Pixel capacity– V0 … Breakdown voltage
d
Pedestal
1 p.e.
2 p.e.
3 p.e.
400 pixelwith x63 amp
LED MPPC
The MPPC Gain
Over-voltage
![Page 8: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/8.jpg)
Breakdown voltage
Num
ber o
f sam
ples
• 400 MPPCs have been delivered for a coming ECAL beamtest, and we have measured all of them.• Obserbed variation of breakdown voltage is small enough and acceptable.
Variation of C and V0 over 400 MPPCs
RMS ~ 0.4 V
Measured at 15oC
Pixel capacity
RMS ~ 3%
![Page 9: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/9.jpg)
Rate of Dark NoiseDark noise : Avalanche signal caused by thermal electrons • 30 oC
• 25 oC• 20 oC• 15 oC• 10 oC• 0 oC• -20 oC
Threshold
0.5 p.e.0.5 p.e. Threshold
• Dark noise rate increases with over-voltage.• It is also affected by temperature.• Typical noise rate is order of 100 kHz with 1600 pixel MPPC.
![Page 10: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/10.jpg)
Cross-talkThe inter-pixel cross-talk to adjacent pixels is caused by photons created in an avalanche.
Method to measure:2 pixels fired signals in dark noise is caused by the cross-talk effect.
Cross-talk prob. increases with over-voltage, but not affected by temperature.
• 30 oC• 25 oC• 20 oC• 15 oC• 10 oC• 0 oC• -20 oC
![Page 11: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/11.jpg)
Photon Detection Efficiency (P.D.E)
• Q.E. : Probability of electron-hole production by single photon• Geiger : Probability that a photoelectron induces an avalanche• geom : Fraction of sensitive region in a sensor ( Geometrical Efficiency)
Measurement method•Inject same light pulse into both MPPC and PMT, and compare light yield measurede by MPPC and PMT.
geomGeigerMPPC EQ ..
MPPC
0.5 mm Pin-holePMTLEDWLSF
PMTPMTep
MPPCep
MPPC NN
..
..~ 16 %
![Page 12: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/12.jpg)
Photon Detection Efficiency
• P.D.E of the MPPC is ~20%, which is comparable to PMT (for 1600 pixel).
• Dominant uncertainty comes from uncertainty of PMT’s P.D.E.
@ 25oC
![Page 13: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/13.jpg)
So the MPPC is satisfactory for the GLD calorimeter readout?
• Gain: ~ at least 105
• Dynamic range: satisfactory to measure EM shower maximum– need ~5000 pixels
• Photon Detection Efficiency should be comparable to PMT to distinguish MIP signal• Noise rate : < 1 MHz (threshold = 0.5 or 1.5 p.e)• Small package suitable to attach to the scintillator strips• good uniformity, small cross-talk• Timing Resolution ~ 1 nsec
– Necessary for bunch ID, slow neutron separation• Should be stable against bias voltage / temperature / time• Price !
Requirements for the GLDCAL readout
The MPPC is feasible for the GLD calorimeter,but still need more improvements.
![Page 14: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/14.jpg)
Improvement is ongoingWe are improving the MPPC collaborating with Hamamatsu photonics.Evaluate performance of the MPPC prototypes
Provide feedback, requirements and suggestions to HPK
Improved samples from HPK
We are still improving performance of the MPPC.In some future we will have the MPPC with
sufficient performance for our requirements.
![Page 15: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/15.jpg)
If you are interested in the MPPC …Yes, now you can buy it !
Number of pixels 100 400 1600Sensor size 1 x 1 mm2
Nominal Bias Volt. 70 10 V 77 10 VGain (x 105) 24.0 7.5 2.75
Noise Rate (kHz) 400 270 100Photon Detection Efficiency 65 % 50 % 25 %
Temperature dependence (V0/T) 50 mV / oC
• Hamamatsu is starting to deliver the MPPC. See following page for more information:
http://www.hamamatsu.com/news/2006/2006_10_26.html
(Numbers from HPK catalog)
![Page 16: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/16.jpg)
Summary• The Multi Pixel Photon Counter is a new and promising
photon sensor.• It has many advantages comparing with photomultiplier and
suitable for the GLD calorimeter readout.• However there are still some points necessary to be
improved (dynamic range, temperature dependence, etc..)• We are improving these points with Hamamatsu photonics and we will have a sufficient performance in future.
Plans• Perform a ECAL beam test with full MPPC readout ( next talk).• After the beam test, we will study robustness, long-term stability, radiation
hardness, magnetic field tolerance, timing resolution.• Of course we will continue to improve the MPPC performance collaborating
with Hamamatsu.
![Page 17: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/17.jpg)
Backups
![Page 18: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/18.jpg)
Over voltage (Vbias-V0) Over voltage (Vbias-V0)
Noise rate
(Hz)
Cross-talk probability
![Page 19: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/19.jpg)
Temperature dependence of V0
V0/T= (56.0 ± 0.1) mV/oC
![Page 20: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/20.jpg)
KEK Detector Technology ProjectPhoton Sensor Group
(http://rd.kek.jp/)(KEK, Kobe, Kyoto, Nagoya, Nara-WU, NDA, Shins
hu, Tokyo/ICEPP, Tsukuba)
• Develop and study the MPPC with Hamamatsu• Aiming to have satisfactory performance to use at :
– GLD calorimeter– T2K near detector– Belle Aerogel Cerenkov Counter
• Provide important feedbacks to Hamamatsu for improvement of fundamental properties
![Page 21: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/21.jpg)
Noise rate
(kHz)
Cross-talk
probability
Bias voltage (V)
Cross-talk =NR(>1.5p.e.)NR(>0.5p.e.)
>0.5 p.e.
>1.5 p.e.
Noise Rate, Cross-talk
![Page 22: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/22.jpg)
MPPC mass measurement
Shaper & AmpMPPC
boardADCBias
voltage source
Thermostatic chamber(kept at 15oC)
Blue LED
Discri Scaler
MPPC
![Page 23: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/23.jpg)
Noise rate
(kHz)
Cross-talk
probability
•Error bars mean variation (RMS) over 400 MPPCs
39%27%
23%21%
23%
30%
RMS/Mean=60%
70%48%
59%
63%
58%
47%
RMS/Mean=27%
Variation of Noise Rate, Cross talk over 400 MPPCs
Bias voltage (V)
![Page 24: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/24.jpg)
Photon Detection Efficiency by Hamamatsu
![Page 25: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/25.jpg)
1600 pixelResponse curve(simulation)
Light input (photoelectrons)• The MPPC is a non-linear device.• One pixel can count only one photon, even if there are 2 or more
photons injected.• Need to increase number of pixels to improve the dynamic
range. (currently 1600 pixels is maximum)About 5000 pixels is necessary to measure high energy
electromagnetic shower maximum
Need More Dynamic Range !
![Page 26: Study of the MPPC for the GLD Calorimeter readout](https://reader036.fdocuments.net/reader036/viewer/2022062410/568160ef550346895dd025b1/html5/thumbnails/26.jpg)
The MPPC is drastically evolving …
Mar. 2005●100/400 pixels●First sample from Hamamatsu
Jan. 2006●100/400/1600 pixels●Smaller pixel size results in more number of pixels
Oct. 2006●100/400/1600 pixels commercialized●Improved Gain and dark noise
Sometime in future●Larger sensor area●More number of pixels●And perhaps more…
?