Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup

Kevin A. Bors, Sabbir Liakat, Anna P. M. Michel, and Claire F. Gmachl

Page 2: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

• Quantum Cascade Lasers– More efficient energy solutions– Field testing– Good for developing countries

• Mid-Infrared Technologies for Health and the Environment

2

MIRTHE and General Motivations for Research

Page 3: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

Specific Motivation for Research

• Diabetes patients

3

Example absorption spectrum of glucose

103

6

108

0

110

6

115

2

Page 4: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

Experimental Setup

• BARD (bi-axial rotation device)

• QCL (Quantum Cascade Laser)

4

Page 5: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

• Close-up of BARD setup

5

Experimental Setup

Page 6: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

6

Program Capabilities

Variables Controlled by Program:• Axis of rotation• Range and precision

of angular movements of that axis

• Position of other axis• Range and Precision

of Wavenumber Movements

Page 7: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

• Example scan using program

7

Results of an Automated Scan Measuring Reflected Light as a Function of Position

Backscattered Light Intensity for Incidence φ=40°

Page 8: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

Results of an Automated Scan Measuring Reflected Light as a Function of Position

• Light is Scattered by Dermis (Inner Layer of Skin)

• Glucose here proportional to level in blood

• Absorption Spectroscopy

8

Page 9: Study of Mid-Infrared Light Scattering Due to Skin for a Non-Invasive Glucose Monitor with an Automated Setup Kevin A. Bors, Sabbir Liakat, Anna P. M.

• Non-invasive glucose sensing• Automation of BARD

• Independent work

• Thanks to PEI, MIRTHE, and Professor Gmachl’s Group

9

Summary, Future Work, and Acknowledgements