Studies for a silicon detector in a e/A collider Benedetto Di Ruzza
-
Upload
zenia-chang -
Category
Documents
-
view
36 -
download
2
description
Transcript of Studies for a silicon detector in a e/A collider Benedetto Di Ruzza
Studies for a silicon detector in a e/A colliderBenedetto Di Ruzza
BNL EIC Task Force meeting August 28th 2014
2
• Momentum resolution studies for a silicon detector in a eRHIC collider using the EICRoot framework.• Some consideration on bremsstrahlung for
electron in silicon.• The ITS Alice upgrade.
outline
3
Momentum resolution studies performed using a simple detector model in the EICRoot framework
Momentum resolution studies
4
Detector model: barrelMomentum resolution studies
Electron energies: 5, 15 and 20 GeVEta : 0, 0.5, 1,1.5, 2, 2.5, 3
Forward and Rear:
7
Crystal ball function like function used in the fit:Momentum resolution studies
P0= alpha, P1= n; P2= mean, P3= sigma, P4=N
12
electron bremsstrahlung in SiSome calculation with X0 =9.36 cm
Fraction of energy loss by electrons for bremsstrahlungFor 300 µm silicon: exp -(0.03/9.36)=0.0032
Other calculation: using the Bremsstrahlung energy spectrum
13
electron bremsstrahlung in SiSome calculation with X0 =9.36 cm
(thanks to Sasha Bazilevsky for useful discussions)Fraction of energy loss by electrons for bremsstrahlung:Numerical calculation using bremsstrahlung gamma spectrum from PDG:
Ratio of Integral over all spectrum/incoming energy = 0.0032
Number of gammaEnergy (Gev)