Studies for a silicon detector in a e/A collider Benedetto Di Ruzza

26
Studies for a silicon detector in a e/A collider Benedetto Di Ruzza BNL EIC Task Force meeting August 28 th 2014

description

Studies for a silicon detector in a e/A collider Benedetto Di Ruzza. BNL EIC T ask Force meeting August 28 th 2014. outline. Momentum resolution studies for a silicon detector in a eRHIC collider using the EICRoot framework. - PowerPoint PPT Presentation

Transcript of Studies for a silicon detector in a e/A collider Benedetto Di Ruzza

Studies for a silicon detector in a e/A colliderBenedetto Di Ruzza

BNL EIC Task Force meeting August 28th 2014

2

• Momentum resolution studies for a silicon detector in a eRHIC collider using the EICRoot framework.• Some consideration on bremsstrahlung for

electron in silicon.• The ITS Alice upgrade.

outline

3

Momentum resolution studies performed using a simple detector model in the EICRoot framework

Momentum resolution studies

4

Detector model: barrelMomentum resolution studies

Electron energies: 5, 15 and 20 GeVEta : 0, 0.5, 1,1.5, 2, 2.5, 3

Forward and Rear:

5

In each configuration performed the simulation of 2000 events.

Momentum resolution studies

6

Crystal ball function “like” used in the fit fit:

Momentum resolution studies

7

Crystal ball function like function used in the fit:Momentum resolution studies

P0= alpha, P1= n; P2= mean, P3= sigma, P4=N

8

Ratio tail/all events

Momentum resolution studies

9

• Repeat the fit with a crystal ball function • change particles and detector design

Still to do:

10

electron bremsstrahlung in Si

Plot Energy loss in leadCritical energy From PDG 2013

Si Z=14

11

electron bremsstrahlung in Si

12

electron bremsstrahlung in SiSome calculation with X0 =9.36 cm

Fraction of energy loss by electrons for bremsstrahlungFor 300 µm silicon: exp -(0.03/9.36)=0.0032

Other calculation: using the Bremsstrahlung energy spectrum

13

electron bremsstrahlung in SiSome calculation with X0 =9.36 cm

(thanks to Sasha Bazilevsky for useful discussions)Fraction of energy loss by electrons for bremsstrahlung:Numerical calculation using bremsstrahlung gamma spectrum from PDG:

Ratio of Integral over all spectrum/incoming energy = 0.0032

Number of gammaEnergy (Gev)

14

The Alice ITS upgrade

15

The Alice ITS upgrade

16

The Alice ITS upgrade

17

The Alice ITS upgrade (inner barrels)

18

The Alice ITS upgrade (outer barrels)

19

New model implemented in the simulation by Alexander

20

New model implemented in the simulation by Alexander

21

New model implemented in the simulation by Alexander

22

The ITS upgrade cooling system

23

The ITS upgrade cooling system

24

ratio

Momentum resolution studies

25

ratio

Momentum resolution studies

26

ratio

Momentum resolution studies