Page 1: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

StorageTek™Host Software

MVS software

Reference SummaryPart Number: 312597501

Version: 6.1

Component (HSC)

Revision:E

Page 2: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information
Page 3: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Host Software Component(MVS Implementation)

Reference Summary

Release 6.1

312597501

Page 4: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.

U.S. Government Rights - Commercial Software. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements.

Sun, Sun Microsystems, the Sun logo, Sun Fire and The Network Is The Computer are trademarks or registered trademarks of Sun Microsystems, Inc. or its subsidiaries, in the U.S. and other countries.

Products covered by and information contained in this service manual are controlled by U.S. Export Control laws and may be subject to the export or import laws in other countries. Nuclear, missile, chemical biological weapons or nuclear maritime end uses or end users, whether direct or indirect, are strictly prohibited. Export or reexport to countries subject to U.S. embargo or to entities identified on U.S. export exclusion lists, including, but not limited to, the denied persons and specially designated nationals lists is strictly prohibited.

DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, États-Unis. Tous droits réservés.

Droits du gouvernement des États-Unis. Logiciel Commercial. Les droits des utilisateur du gouvernement des États-Unis sont soumis aux termes de la licence standard Sun Microsystems et aux conditions appliquées de la FAR et de ces compléments.

Sun, Sun Microsystems, le logo Sun, Sun Fire et The Network Is The Computer sont des marques de fabrique ou des marques enregistrées de Sun Microsystems, Inc. ou ses filiales, aux États-Unis et dans d'autres pays.

Les produits qui font l'objet de ce manuel d'entretien et les informations qu'il contient sont regis par la legislation americaine en matière de contrôle des exportations et peuvent être soumis au droit d'autres pays dans le domaine des exportations et importations. Les utilisations finales , ou utilisateurs finaux, pour des armes nucleaires, des missiles, des armes biologiques et chimiques ou du nucleaire maritime, directement ou indirectement, sont strictement interdites. Les exportations ou reexportations vers des pays sous embargo des États-Unis, ou vers des entites figurant sur les listes d'exclusion d'exportation americaines, y compris, mais de maniere non exclusive, la liste de personnes qui font objet d'un ordre de ne pas participer, d'une façon directe ou indirecte, aux exportations de des produits ou des services qui sont regi par la legislation americaine sur le contrôle des exportations et la liste de ressortissants specifiquement designes, sont rigoureusement interdites.

LA DOCUMENTATION EST FOURNIE "EN L'ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITE MARCHANDE, À L'APTITUDE À UNE UTILISATION PARTICULIERE OU À L'ABSENCE DE CONTREFAÇON.

Page 5: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Document Effectivity

EC Number Date Doc Kit Number Type Effectivity

132084 February, 2005 --- First Edition This document applies to the Host Software Component for MVS (MVS/HSC), Version 6.1.

132553 February, 2006 --- Revision B

--- April, 2008 --- Revision C

--- September, 2008 --- Revision D

--- May, 2009 --- Revision E

Document Effectivity iiiRev. E, 5/31/09 - 312597501

Page 6: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

iv HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 7: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Contents

About this Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

Other HSC Books to Help You . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Syntax Flow Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Specifying Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Delimiters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Flow Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Single Required Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Single Optional Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Repeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Syntax Continuation (Fragments) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Library Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5How to Specify a CAPid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CAPid Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Ranges and Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Control Statement Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

LIBGEN Macro Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

SLIACS macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIALIST macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIDLIST macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIDRIVS macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIENDGN macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLILIBRY macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17SLILSM macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18SLIRCVRY macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18SLISTATN macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Utility Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

ACTivities Report utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22AUDIt utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22BACKup utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Database Decompile (LIBGEN) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Directory Rebuild (DIRBLD) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Contents vRev. E, 5/31/09 - 312597501

Page 8: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

EJECt utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24INITialize Cartridge utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Journal OFFLoad utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MERGEcds utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MOVe utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Reconfiguration utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26REPLace utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RESTore utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26SCRAtch utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Scratch Conversion utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Scratch Redistribution (SCREdist) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28SET utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29UNSCratch utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30UNSElect utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Volume Report (VOLRpt) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Control Statement Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Control Data Set Definition (CDSDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34EXECParm control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Journal Definition (JRNDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34License Key Definition (LKEYDEF) command and control statement . . . . . . . . . . . . . . . . . . . . . 35License Key Information (LKEYINFO) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35LMUPATH control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35LMUPDEF command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35OPTion control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Reconfiguration Definition (RECDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Scratch Subpool Definition (SCRPDEF) command and control statement . . . . . . . . . . . . . . . . . . 36Scratch Subpool (SCRPOol) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37User Exit command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Volume Attribute (VOLATTR) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Volume Attribute Definition (VOLDEF) command and control statement . . . . . . . . . . . . . . . . . . 39

HSC Operator Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Allocation (ALLOC) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41CAP Preference (CAPPref) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41CDs Enable/Disable command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42CLean command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Communications Path (COMMPath) command and control statement . . . . . . . . . . . . . . . . . . . . . 43DISMount command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Display command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44DRAin CAP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52EJect command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53ENter command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Journal command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54MODify command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54MONITOR command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

vi HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 9: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Mount command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Mount/Dismount Options (MNTD) command and control statement . . . . . . . . . . . . . . . . . . . . . . . 56MOVe command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56OPTion command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57RECover Host command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57RELease CAP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57SENter command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58SRVlev command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Stop Monitoring (STOPMN) command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58SWitch command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58TRace command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59TRACELKP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59User Exit (UEXIT) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Vary Station command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60VIew command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Warn command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

HSC Diagnostic Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

LIst command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64TRace command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Contents viiRev. E, 5/31/09 - 312597501

Page 10: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

viii HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 11: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

About this Summary

This summary contains frequently used syntax information associated with Release 6.1.0 of the Host Software Component (MVS Implementation).

Use the material presented here as a memory aid. We assume that you are an experienced user who has worked with the Host Software Component at the programmer level. With this in mind, explanatory text has been kept to a minimum.

The following information appears in this reference summary:

• syntax conventions• LIBGEN macro syntax• control statement syntax• utility syntax • operator command syntax• diagnostic command syntax.

Other HSC Books to Help You

This summary supplements existing HSC 6.1.0 documentation. For more detailed information about a topic, refer to the following manuals:

• HSC Configuration Guide• HSC System Programmer’s Guide • HSC Operator’s Guide• HSC Messages and Codes Guide.

About this Summary ix

Rev. E, 5/31/09 - 312597501

Page 12: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

x HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 13: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Syntax Conventions

Syntax Flow Diagrams

Syntax is illustrated using flow diagrams. These can include the following elements:

• Syntax – the diagram itself.

• Items – individual elements inside the diagram. Items can be keywords, variables, delimiters, operators, fragment references, and separators.

• Groups – a collection of items or other groups.

The following sections describe syntax flow diagram features and include some generic examples.

Specifying Commands

Commands are composed of command names, keyword parameters, and positional parameters. Command names initiate command execution, keyword parameters are operands that contain keywords and their related values, and positional parameters are operands that are identified by their position in the command string rather than by keywords.

• Keyword parameters can be specified in any order. The HSC accepts (tolerates) multiple occurrences of a keyword. The value assigned to a keyword reflects the last occurrence of a keyword within a command.

• Positional parameters must be entered in the order shown in the syntax diagram.

• Uppercase letters indicate the minimum abbreviation for the command name, keyword, or positional parameter.

Variables

Variables are italicized.

Delimiters

If a comma(,), a semicolon(;), or other delimiter is shown with an element of the syntax diagram, it must be entered as part of the statement or command.

Syntax Conventions 1

Rev. E, 5/31/09 - 312597501

Page 14: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Flow Lines

Syntax diagrams consist of horizontal and vertical lines and the text of a command, control statement, macro, or utility.

or

Diagrams are read left to right and top to bottom. Arrows show flow and direction.

• a statement begins with

• a statement ends with

• diagrams continuing to the next line begin with

• fragments begin and end with |

Single Required Choice

Branch lines, without repeat arrows, indicate that a single choice must be made. If one of the items from which a choice is being made is on the base line of the diagram, a single choice is required.

COMMAND/MACRO/UTILITY

Item1Item2Item3

COMMAND/UTILITY NAME

Item3(variable5)

Item1(variable1) Item2( variable2variable3variable4

)

Item1Item2Item3

2 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 15: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Single Optional Choice

If the first item is on the line below the base line, a single choice of items in the stack is optional.

Defaults

Default values and parameters appear above the syntax diagram line. In the following example, if a value is not specified with the command, Default Value is used by the HSC.

Some keyword parameters provide a choice of values in a stack. When the stack contains a default value, the keyword and the value choices are placed below the baseline to indicate that they are optional, and the default value appears above the keyword line. In the following example, if the keyword is not specified with the command, Keyword(Default Value) is used by the HSC.

Repeat Symbol

A repeat symbol indicates that more than one choice can be made or that a single choice can be made more than once. The repeat symbol shown in this example indicates that a comma is required as the repeat separator.

Item3

Item1Item2

Value2Value3

Default Value

Keyword

Value3

Default ValueValue2

,variable

Syntax Conventions 3Rev. E, 5/31/09 - 312597501

Page 16: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Syntax Continuation (Fragments)

Fragment references direct you to parts (fragments) of the syntax that contain more detail than can be shown in the main syntax diagram.

COMMAND/UTILITY NAME Fragment Reference

Item1(

Fragment:

variable2,variable1

variable4variable3 )

Item2(variable6

,variable5variable8variable7 )

4 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 17: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Library Identification

Each ACS, LSM, and CAP is assigned a unique identification number during LIBGEN. Use this number in HSC commands and utilities when identifying a specific ACSid, LSMid, or CAPid.

• ACSid (acs-id) is a hexadecimal value from 00 through FF that identifies the LMU.

An acs-id is the result of defining the SLIALIST macro during a LIBGEN. See “LIBGEN Macros” in the HSC Configuration Guide for information about the SLIALIST macro. The first ACS listed in this macro acquires a hexadecimal identifier of 00, the second ACS listed acquires a hexadecimal identifier of 01, and so forth until all ACSs are identified.

• An LSM number (ll) is a hexadecimal value from 00 through 17. It differentiates an LSM from every other LSM connected to the same LMU.

An LSM number is the result of defining the SLIACS macro LSM parameter. See the HSC Configuration Guide for information about the SLIACS macro. The first LSM listed for an ACS acquires a hexadecimal number of 00, the second LSM listed for an ACS acquires a hexadecimal number of 01, and so forth.

• An LSMid (lsm-id) is made up of the ACSid and the LSM number separated by a colon (:). It differentiates an LSM from every other LSM in a library.

• A CAP number is a hexadecimal value from 00 to 02 for all existing libraries, except for SL3000 libraries. The CAP number for an SL3000 is a hexadecimal value from 00 to 0B. The CAP number identifies a specific CAP in an LSM that has more than one CAP.

• A CAPid (cap-id) is a hexadecimal value made up of the LSMid and the CAP number separated by a colon. Refer to “How to Specify a CAPid” on page 6 for more information.

Some HSC commands and utilities require, or optionally allow, the user to specify a host identifier or a VOLSER.

• The host-id for a given host is the identifier specified in the HOSTID parameter of the SLILIBRY macro in the LIBGEN. The HOSTID parameter is the SMF system identifier for both JES2 and JES3. Valid characters for a HOSTID are A-Z, 0-9, #, $ and @.

• A VOLSER (volser) identifies a volume serial number consisting of one to six characters. Valid characters are A-Z, 0-9, # (crosshatch), $, ¥ (yen character), and optional trailing blanks. Leading blanks are not allowed.

Syntax Conventions 5Rev. E, 5/31/09 - 312597501

Page 18: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

How to Specify a CAPid

A CAPid specifies a particular CAP in the library. Each CAP is identified by the LSMid of the LSM that the CAP is attached to and a CAP number to distinguish it from other CAPs in that LSM.

CAP configurations differ based on the LSM type. The following configurations are possible:

LSM (Model 4410) and PowderHorn LSM (Model 9310) can be configured with either the standard 21-cell CAP or an enhanced CAP. An enhanced CAP contains two 40-cell magazine-style CAPs and a one-cell priority CAP (PCAP). The 40-cell CAPs function independently.

WolfCreek LSM (Models 9360-050, 9360-075, and 9360-100) configured with a WolfCreek CAP which contains a 20-cell magazine-style CAP and a PCAP. An optional 30-cell, magazine-style CAP, called a WolfCreek optional CAP, may be added to the WolfCreek CAP.

TimberWolf LSM (Model 9740) configured with either a 14-cell permanent rack or a 10-cell removable magazine.

StreamLine Library (Model SL3000) The library is configured with 2, 13-cell removable magazines in each CAP. This library can contain up to 12 CAPs (00-0B).

StreamLine Library (Model 8500)This library is configured with 3, 13-cell removable magazines. An optional 39-cell CAP can be added.

6 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 19: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

CAPid Formats

There are two formats that can be used to specify a CAPid:

• AA:LL, where AA is the ACSid and LL is the LSM number. This format is referred to as the lsm-id.

• AA:LL:CC, where AA:LL is the LSMid and :CC is the CAP number. This format is referred to as the cap-id.

Caution: Do not use a colon as the MVS command delimiter because the system will process the colon in the new CAPid format as the end of the command. All information following the colon in an HSC command will not be processed.

The appropriate format to use is determined by the CAP hardware and the command being specified.

• The AA:LL format can be specified in the following situations:

- to specify a standard CAP - to allow the HSC to select a CAP based on CAP preference.

• The AA:LL:CC format can be specified for any CAP hardware in any command that accepts a CAPid. This is the preferred format. Valid CAP numbers are:

00 indicates one of the following:

• a 21-cell 4410 or 9310 standard CAP• the right-hand 40-cell 4410 or 9310 enhanced CAP• the 20-cell 9360 WolfCreek CAP• a 14-cell or 10-cell removable magazine 9740 TimberWolf CAP• a left-side SL3000 AEM CAP, consisting of 18, 13-cell removable magazines • the left-hand 39-cell SL8500 library CAP.

01 indicates one of the following:

• the left-hand 40-cell 4410 or 9310 enhanced CAP• the 30-cell 9360 WolfCreek optional CAP• an optional SL3000 CEM CAP consisting of 2, 13-cell removable magazines• the right-hand optional 39-cell SL8500 library CAP.

02 indicates one of the following:

• PCAP in either a 4410 or 9310 enhanced CAP or a 9360 WolfCreek CAP.• an optional SL3000 CEM CAP consisting of 2, 13-cell removable magazines.

03, 04, 05 indicates the following:

• an optional SL3000 CEM/DEM CAPs each consisting of 2, 13-cell removable magazines.

Syntax Conventions 7Rev. E, 5/31/09 - 312597501

Page 20: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

06 indicates the following:

• the only required SL3000 BDM CAP consisting of 2, 13-cell removable magazines.

07, 08, 09, 0A indicates the following:

• an optional SL3000 CEM CAPs each consisting of 2, 13-cell removable magazines.

0B indicates the following:

• a right-side SL3000 AEM CAP, consisting of 18, 13-cell removable magazines

Notes:

• If SL3000 library CAPs are not present, the HSC reports them as “not installed” This keeps CAP addresses from changing as new CAPs are added.

• Refer to the individual command explanations for additional information on specifying CAPids.

• SL3000 and SL8500 libraries do not contain a PCAP.

8 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 21: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Ranges and Lists

HSC commands and utilities often allow the user to specify ranges and lists of elements.

1. An inclusive range is indicated by a pair of elements of the same length and data type, joined by a dash. The first element must be strictly less than the second element.

• A hexadecimal range consists of a pair of hexadecimal numbers (for example, 0A2-0AD, or 000-0FC).

• A decimal range consists of a pair of decimal numbers (for example, 1-9, or 010-094). Leading zeros are not required.

• A numeric VOLSER range (vol-range) consists of a pair of VOLSER elements containing a decimal numeric portion of 1 to 6 digits (for example, ABC012-ABC025, or X123CB-X277CB). The decimal portion is referred to as an incremental range. The following additional restrictions apply:

- The character positions of the incremental portion of both range elements must match.

- The non-incremental characters of the first element must be identical to those of the second element.

- You cannot increment two portions of a range element. If 111AAA is the first element, you cannot specify 112AAB for the second element.

- If a VOLSER range contains more than one decimal portion, any portion is valid as the incremental range. For example:

Note: A VOLSER range for most operator commands is limited to 100 entries. If a larger range is entered, only the first 100 VOLSERs in the range are acted on. If HSC utilities are used, the entire range is processed.

• An alphabetic VOLSER range (vol-range) consists of a pair of VOLSER elements containing an incremental portion of 1 to 6 characters (for example, 000AAA-000ZZZ, or 9AAA55-9ZZZ55). This portion is referred to as an incremental range. The following additional restrictions apply:

- The character positions of the incremental portion of both range elements must match.

- The non-incremental characters of the first element must be identical to those of the second element.

A00B00 the largest range that can be specified is A00B00 through A99B99.

A0B0CC the largest range that can be specified is A0B0CC through A9B9CC.

000XXX the largest range that can be specified is 000XXX through 999XXX.

Syntax Conventions 9Rev. E, 5/31/09 - 312597501

Page 22: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

- You cannot increment two portions of a range element. If 111AAA is the first element, you cannot specify 112AAB for the second element.

- The alphabetic portion of the VOLSER range is defined as being from character A to Z. To increment multi-character sequences, each character increments to Z. For instance, ACZ is part of the AAA-AMM range. Examples are:

The number of volumes in an alphabetic VOLSER range depends on the number of elements in the incrementing portion of the VOLSER range. For an A to Z range in each character position, the number of volumes can be calculated by 26 to the power of the number of positions that are being incremented.

Note: For most operator commands, a VOLSER range is limited to 100 entries. If a large range is entered, only the first 100 VOLSERs are acted upon. If HSC utilities are used, the entire range is processed.

A00A0-A99A0 increments VOLSERs A00A0 through A09A0, then A10A0 through A99A0.

9AA9A-9ZZ9A increments VOLSERs 9AA9A through 9AZ9A, then 9BA9A through 9ZZ9A.

111AAA-111ZZZ increments VOLSERs 111AAA through 111AAZ, then 111ABA through 111ZZZ.

999AM8- 999CM8 increments VOLSERs 999AM8 through 999AZ8, then 999BA8 through 999CM8

A3BZZ9- A3CDE9 increments VOLSERs A3BZZ9 through A3CAA9, then A3CAB9 through A3CDE9

AAAAAA-AAACCC

increments VOLSERs AAAAAA through AAAAAZ, then AAAABA through AAACCC

CCCNNN-DDDNNN

increments VOLSERs CCCNNN through CCCNNZ, then CCCNOA through DDDNNN*

* Caution: This is a very large range.

A-Z 261 26

AA-ZZ 262 676

AAA-ZZZ 263 17,576

AAAA-ZZZZ 264 456,976

AAAAA-ZZZZZ 265 11,881,376

AAAAAA-ZZZZZZ 266 308,915,776

10 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 23: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

2. A list consists of one or more elements. If more than one element is specified, the elements must be separated by a comma or a blank, and the entire list enclosed in parentheses.

• For some HSC operator commands, an element may consist of a single item or a range. Refer to the individual command explanations for valid list entries.

• In general, HSC utilities do not allow ranges to be specified in a list. The exception to this is a VOLSER list (vol-list) which does allow ranges to be specified.

For VOLATTR control statements, you can use wildcard characters (%, ?, or *) to identify a list of VOLSERs.

Syntax Conventions 11Rev. E, 5/31/09 - 312597501

Page 24: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Control Statement Syntax Conventions

The control statement for each utility program consists of a command (indicating the utility function) followed by parameters, as applicable, in 80-character card-image records. The standard syntax conventions for control statements are as follows:

• The only valid control statement information area is from column 2 to column 72. Columns 73-80 are ignored.

• Parameters are separated by one or more blanks or a comma.

• A value is associated with a parameter by an equal sign (=) or by enclosing the value in parentheses, and concatenating it immediately after the parameter.

• Case (upper or lower) is ignored in actual control statements.

• Control statements may be interspersed with comments designated by an asterisk (*) in column one.

For definition data sets (VOLATTRs, UNITATTRs and TAPEREQs) comments must be in the new format (/*...*/). Asterisk (*) comments are not allowed. A /*...*/ comment in the first line is not required for definition data sets.

• A control statement is terminated if the statement is not continued. Control statements must have a /*...*/ comment as the first control statement in the PARMLIB member. A PARMLIB member that does not begin with a /*...*/ style comment is assumed to be in the old format. Comments in old format members must begin with an asterisk in column 1.

In contrast to utility control statements, PARMLIB control statements may begin in column 1. Columns 73-80 are ignored.

To allow for continuation, comments in the job stream must start with /* and end with */. Comments cannot be nested, and mixing the two comment styles (* and /*) is not allowed.

• The 80-character card-image records use conventional continuation rules.

- A space and a dash (–) following a parameter or parameter value indicates that a blank is to be inserted between the last nonblank character of this line and the first nonblank character of the next nonblank record.

- A plus sign (+) specifies that the continued control information is to be concatenated directly after the character preceding the plus sign. The continued data starts at column two of the next nonblank record.

Note: You can use a continuation only after a new keyword or after the natural end of a value. Some examples follow.

12 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 25: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

The following examples illustrate continuations used correctly:

SCRPOOL NAME=STD36,RANGE+ (AAA000-AAA999,ZZZ000-ZZZ999)

SCRPOOL NAME=STD36,RANGE(AAA000-AAA999,- ZZZ000-ZZZ999)

The following example illustrates a continuation used incorrectly:

SCRPOOL NAME=STD36,RANGE(AAA000-AAA999,ZZZ+ 000-ZZZ999)

- Users must enter a nonblank character in column 72 (e.g., an X).

- PARMLIB control statements can be continued using the preceding continuation rules only if they are new format control statements.

• The maximum length of a control statement is 32,767 characters.

• The maximum length of a command (used as a command or in PARMLIB) is 126 characters.

Syntax Conventions 13Rev. E, 5/31/09 - 312597501

Page 26: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

14 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 27: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

LIBGEN Macro Syntax

This section contains the syntax for LIBGEN macros presented in alphabetical order. For complete descriptions of the macros and the required order for specifying them, see the HSC Configuration Guide.

LIBGEN Macro Syntax 15

Rev. E, 5/31/09 - 312597501

Page 28: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SLIACS macro

SLIALIST macro

SLIDLIST macro

SLIDRIVS macro

SLIENDGN macro

acs0 SLIACS Additional Parameters

Additional Parameters:

ACSDRV=(esoteric0, ...,esoteric15)

,STATION=(station0, ...,station15),LSM=(lsm0,lsm1, ...,lsm23)

,FUTRLSM=(8500,lsmnum)

acslist SLIALIST acs0, acs1,.....acs255

drvelst0 SLIDLIST HOSTDRV= (drives0,...,drives15)

drives0 SLIDRIVS ADDRESS=(addr0,addr1...)

SLIENDGN

16 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 29: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SLILIBRY macro

SLILIBRY HOSTID=(host-id0,host-id1,...,host-id15) ,ACSLIST=acslist

Optional Parameters

Optional Parameters:

,CLNPRFX= prefixCLN

,SMF= libtype255

,MAJNAME= qnameSTKALSQN

,COMPRFX= commandchar.

,SCRLABL=NLNSL

SLAL

,EJCTPAS=password ,DRVHOST=(host-id) FUTRACS=(x,y)

LIBGEN Macro Syntax 17Rev. E, 5/31/09 - 312597501

Page 30: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SLILSM macro

SLIRCVRY macro

S (ptppanel8, SM

)) ,ADJACNT=(lsm1,...,lsm4)

,DOOR= STD,WINDOW=(wndpanel0,...,wndpanel3)

100

TYPE=441093109360

075050

,

-

9740

SLILSMlsm0

,PASTHRU=((ptppanel0,M

),...,

WC1ECAP

WC28500-1

8500-2

8500

,DRVELST=(drvelst0,...,drvelst3)DRIVE=(drvpanel0,...,drvpanel3)

3000

3000

labelSLIRCVRY

TCHNIQE=BOTHNONESHADOW

STANDBYALL

JOURNAL

18 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 31: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SLISTATN macro

station0 SLISTATN ADDRESS=(addr0,...,addr15)

LIBGEN Macro Syntax 19Rev. E, 5/31/09 - 312597501

Page 32: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

20 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 33: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Utility Syntax

This section contains the syntax for library utilities. For complete descriptions of the utilities, see the HSC System Programmer’s Guide.

Utility Syntax 21

Rev. E, 5/31/09 - 312597501

Page 34: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

ACTivities Report utility

AUDIt utility

ACTIvitiesOptional Parameters

Optional Parameters:

BEGIN( begin-dateTODAY

, begin-time00:00:00

END( end-dateTODAY

end-time23:59:59

)

),

AUDIt

Optional Parameters

Optional Parameters:

ACS(acs-id)ALL

APPLy( NO )YES

LSM(lsm-list)PANel(panel-list)

ROW(row-list)COLumn(column-list)

CAP(cap-id) DIAGScan( )ONLYEMPTYCelALSO

INTRANs

22 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 35: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

BACKup utility

Database Decompile (LIBGEN) utility

Directory Rebuild (DIRBLD) utility

BACKupCDS(

PrimarySecondarySTandby

)

OPTion(RestartAnalyzeCopy

)

LIBGEN

DIRBLD

Utility Syntax 23Rev. E, 5/31/09 - 312597501

Page 36: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

EJECt utility

Media Types Recording Techniques

Standard 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

* No corresponding recording technique.

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

EJECt Eject Method 1

Eject Method 2CAP( cap-list )

,

Eject Method 1:

Eject Method 2:

VOLser( vol-list

,

)

SCRTCH

SUBpool(subpool-name) VOLCNT(count)

MEDia( media-type ) RECtech( recording-technique )

SEQ(YESNO )

24 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 37: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

INITialize Cartridge utility

Journal OFFLoad utility

MERGEcds utility

INITializeOptional Parameters

Optional Parameters:

CAP(cap-id)

PROGram( prog-nameIEHINITT

) VERIFY(parameter-name)

CNTLDD( dd-name

SYSIN)

OPTion( EJEctSCRatch

)

OFFLoad

MERGEcdsVALIDate ALL

Utility Syntax 25Rev. E, 5/31/09 - 312597501

Page 38: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

MOVe utility

Reconfiguration utility

REPLace utility

RESTore utility

MOVe Parameters

Parameters:

Flsm(lsm-id) Panel(panel-list)

Volume(vol-list)

Row(row-list)Column(column-list)

TLsm(lsm-list)TPanel(panel)

STARTS

reconfig-procname

REPLaceall

VOLser( vol-list,

)

RESTore

APPly( NO ) GENerate(OnlyShort

YESNO

)YES

26 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 39: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SCRAtch utility

Scratch Conversion utility

SCRAtch VOLser( vol-list,

)

PARM= 'Optional Parameters

'

Optional Parameters:

TLMSRMM

,TMS

SCRPOOL(

,

NSLAL

NL

SUL

SL)

TODAYyyddd1

-yyddd2yyyyddd1

-yyyyddd2

190000100001

,

MIXED,

LIBONLY,

SMC

Utility Syntax 27Rev. E, 5/31/09 - 312597501

Page 40: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Scratch Redistribution (SCREdist) utility

Media Types Recording Techniques

LONGItud, Standard LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

* No corresponding recording technique.

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

SCREdist ACS(acs-id)

LSM( lsm-list,

)SUBpool(subpool-name)

BALtol(tolerance-value) media-type )MEDia(

recording-technique )RECtech(

28 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 41: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SET utility

SET Options

Options:

ACSDRV(esoteric) ,FORACS(acs-id),FORHOST(host-id)

CLNPRFX(prefix)

COMPRFX(cmdhex)

DELDISP( SCRTCHNOSCRTCH

)

HOSTID(newhost),FORHOST(oldhost)

HSCLEVEL(OFF),FORHOST(host-id)

MAJNAME(qname)

FREEZE( ON )OFf

,FORLSMID(lsm-id)

EJCTPAS(newpswd

),OLDPASS(oldpswd)

NNLBDRV(

esoteric

)

,FORHOST(host-id)

SCRLABL( )SL

AL

NL

NSL

NEWHOST(newhost),LIKEHOST(model-host)

host-idOFF )DRVHOST(

,FORPANEL(panel)

Utility Syntax 29Rev. E, 5/31/09 - 312597501

Page 42: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SET utility (continued)

UNSCratch utility

UNSElect utility

SET Options

Options:

SMF(libtype)

TCHNIQE(

JOURNALSHADOWBOTHSTANDBYALL

NONE )

SLIDRIVS(addr0

,...addr31

),FORLSMID(lsm-id),FORPANEL(panel)

,FORHOST(host-id)

SLISTATN(stat1,...,stat16

),FORACS(acs-id),FORHOST(host-id)

UNSCratch VOLser( vol-list,

)

UNSElect VOLser(volser),FORCE

30 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 43: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Volume Report (VOLRpt) utility

VOLRptACS(acs-id)

LSM( lsm-list,

)

VOLser ( volservol-range

vol-list,

)

VOLume ( volservol-range

vol-list,

)

SORT(LOCINSVOL

SELUSE

)DEScend

ASCend

INCLude(

,*SCRNONSCRERR

NONERRSEL

NONSELREADable

UNREADableMEDEQUAL

NONMEDEQ

)EXCLude(

,SCRNONSCRERR

NONERRSEL

NONSELREADable

UNREADableMEDEQUAL

NONMEDEQ

)

NOEXTernalNOEXTernal

VOLDATA

VOLIST

CDSDATA SUMMary( TOTalSUBpoolTOTal,SUBpool

)

NOSORT

Utility Syntax 31Rev. E, 5/31/09 - 312597501

Page 44: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

32 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 45: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Control Statement Syntax

This section contains the syntax for control statements. For complete descriptions of the control statements, see the HSC System Programmer’s Guide.

Control Statement Syntax 33

Rev. E, 5/31/09 - 312597501

Page 46: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Control Data Set Definition (CDSDEF) control statement

EXECParm control statement

Journal Definition (JRNDEF) control statement

CDSDEF DSN1(dataset.name),VOL1(volser),UNIT1(unitname)

,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)

,DSN3(dataset.name),VOL3(volser),UNIT3(unitname) ,DISABLE

EXECParm

MSGPRFX( NoYes

),Eid(gtfeid) ,Fid(gtffid)

,HOSTID(host-id)

,VOL1(volser),UNIT1(unitname)

,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)

,FULL(AbendContinue )

,HOSTID(host-id)

DSN1(dataset.name)JRNDEF

34 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 47: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

License Key Definition (LKEYDEF) command and control statement

License Key Information (LKEYINFO) control statement

LMUPATH control statement

LMUPDEF command and control statement

DATASET(dataset.name)DSN(dataset.name) VOLume(volser)

LKEYDEF

UNIT(unitname) HOSTID(host-id)

LKEYINFO PRODuct(product_identifier) CUSTomer('customer_name')

SITEno(nnnnnnn) EXPRdate(yyyyddd) KEY(license_key_string)

,ACS(aa) LMUADDR(LMUPATH

lmu_hostnamennn.nnn.nnn.nnn

) PARTID(00n)

LMUPDEFDSN(dataset.name)

DATASET(dataset.name)VOLume(volser) UNIT(unitname)

HOSTID( host-id,

)

Control Statement Syntax 35Rev. E, 5/31/09 - 312597501

Page 48: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

OPTion control statement

Reconfiguration Definition (RECDEF) control statement

Scratch Subpool Definition (SCRPDEF) command and control statement

OPTion TITLE(identifying-string)TRACETRACEF

RECDEF DSN1(dataset.name),VOL1(volser),UNIT1(unitname)

,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)

SCRPDEFDSN(dataset.name)

DATASET(dataset.name)VOLume(volser) UNIT(unitname)

HOSTID( host-id,

)

36 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 49: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Scratch Subpool (SCRPOol) control statement

User Exit command and control statement

SCRPOol NAME(subpool-name) subpool-range )

,HOSTID(ALLhost-id

host-list,

,RANGE(

,

) ,LABEL( SLNLALNSL

UEXIT nn

Enable

Load(name

SLSUXnn)

,Disable

,Enable

Disable

nnnn-range

( nn-list,

)

Query

Control Statement Syntax 37Rev. E, 5/31/09 - 312597501

Page 50: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Volume Attribute (VOLATTR) control statement

Media Types Recording Techniques

LONGItud, Standard LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

ECART

ZCART

DD3A, DD3B, DD3C, DD3D HELical, DD3

STK1R, STK1U, STK1Y STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2P STK2W STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

* No corresponding recording technique.

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS, T10000CT T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

VOLATTR SERial( volservol-range

vol-list,

)MEDia( media-type )

RECtech( ) MAXclean(use-limit)recording-technique

38 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 51: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Volume Attribute Definition (VOLDEF) command and control statement

VOLDEFDSN(dataset.name)

DATASET(dataset.name)VOLume(volser) UNIT(unitname)

HOSTID( host-id,

)

Control Statement Syntax 39Rev. E, 5/31/09 - 312597501

Page 52: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

40 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 53: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

HSC Operator Command Syntax

This section contains the syntax for operator commands. For complete descriptions of the commands, see the HSC Operator’s Guide.

Allocation (ALLOC) command and control statement

CAP Preference (CAPPref) command and control statement

ALLOCHOSTID(host-id)

,

LOWscr( NONE )

COUNT )

LSMpref(

9360

44109310

NONE )

SCRtech(

ANY

ROTATE

CAPPref prefvlue lsm-idcap-idcap-range

( cap-list,

)

host-id AUTOMANual

HSC Operator Command Syntax 41

Rev. E, 5/31/09 - 312597501

Page 54: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

CDs Enable/Disable command

CLean command

PrimarySEcndrySTandby

DSn(dsn)Disable

DSn(dsn)CDs EnableNEWVol(volser),NEWUnit(unitname)NEWLoc

EXpand

CLeandev-rangedev-id

( dev-list,

)

host-id

42 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 55: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Communications Path (COMMPath) command and control statement

DISMount command

COMMPath HOSTid(host-id)

METHod(LMUCDS

LMU,acs-idVTAM

)LMUpath( acs-id

acs-range

acs-list,

) VTAMpath(name)

LMUpath( acs-idacs-range

acs-list,

)VTAMpath(name)

VTAMpath(name)

DELete

LMUpath( acs-idacs-range

acs-list,

)VTAMpath

(name)

VTAMpath(name)

DISMountvolser, devaddr

host-id

HSC Operator Command Syntax 43Rev. E, 5/31/09 - 312597501

Page 56: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display command

Display Acs

Display ALl

Display ALLOC

Display Cap

Display CDS

Displayacs-id

Acs

( acs-list,

)

acs-range

Display ALl

Display ALLOC

Display(all CAPs)

Capacs-idlsm-idcap-id

Display CDS

44 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 57: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display Cmd

Display COMMPath

Display command-nameCOmmandCMd

Display COMMPath

HOSTid( ALLhost-id

*

,host-list

)

HSC Operator Command Syntax 45Rev. E, 5/31/09 - 312597501

Page 58: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display DRives

Media Types Recording Techniques Model Types

LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

4480, 4490, 9490, 9490EE

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C, DD3D HELical, DD3 SD3

STK1, STK1R, STK1U, STK1Y STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

9840, 984035, T9840B, T984035B, T9840C, T9840C35, T9840D, T9840D35, T9840DE, T9840DE5

STK2, STK2P, STK2W STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

T9940A, T9940A35, T9940B, T9940B35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W, LTO-CLN1, LTO-CLN2, LTO-CLNU

* HP-LTO2, HP-LTO3, HP-LTO4, IBM-LTO2, IBM-LTO3, IBM-LTO4

Display DRivesLibraryACS(acs-id)

LSM(lsm-id)

DETail ) )

Unit( unit-addressunit-address range

)

RECtech( recording-technique

)MODel( model-type

MEDia( media-type

BYDrive

BYLoc

ACtiveIdle

ALl

46 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 59: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display Exceptions

Display LKEYDEF

Display LMUPDEF

Display LSM

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

* SDLT-600, DLT-S4

T10000T1, T10000TS, T10000CT T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

T1A34, T1A35, T1AE34, T1AE35, T1B34, T1B35, T1BE34, T1BE35

* No corresponding recording technique.

Media Types Recording Techniques Model Types

Display EXceptnsX

Display LKEYDEF

Display LMUPDEF

Display Lsmlsm-idlsm-range

(,lsm-list )

HSC Operator Command Syntax 47Rev. E, 5/31/09 - 312597501

Page 60: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display Message

Display MNTD

Display MONitor

Display OPTion

Display Requests

Display MessageMsg

msgnum

Display MNTD

Display MONitor,PGMI ,L(

namecc )

Display OPTion

Display Requests

48 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 61: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display SCRatch

Media Types Recording Techniques

LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

* No corresponding recording technique.

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

Display SCRatchacs-idlsm-id

SUBpool(subpool-name) DETail

MEDia( media-type ) RECtech( recording-technique )

ALL

HSC Operator Command Syntax 49Rev. E, 5/31/09 - 312597501

Page 62: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display SCRPDEF

Display SRVlev

Display Status

Display THReshld

Media Types Recording Techniques

LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

Display SCRPDEF

Display SRVlev

Display Status

Display THReshldSUBpool(subpool-name) DETail

MEDia( media-type ) RECtech( recording-technique )

acs-idlsm-id

50 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 63: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display TREQDEF

Display UNITDEF

Display VOLDEF

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

* No corresponding recording technique.

Media Types Recording Techniques

Display TREQDEF

Display UNITDEF

Display VOLDEF

HSC Operator Command Syntax 51Rev. E, 5/31/09 - 312597501

Page 64: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Display Volume

DRAin CAP command

DisplayVolumeVolser

vol-rangevolser

( vol-list,

)

DETail

DRAin cap-idEJect

ENter

( )cap-list,

52 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 65: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

EJect command

Media Types Recording Techniques

LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

EJect

Option 2

Option 1

Option 1:

vol-rangevolser

( vol-list,

)

acs-idlsm-idcap-id

( cap-list ),

SCRTCHacs-idlsm-idcap-id

( cap-list ),

SUBpool(subpool-name) VOLCNT(count

Option 2:

MEDia( media-type ) recording-technique )RECtech(

)

HSC Operator Command Syntax 53Rev. E, 5/31/09 - 312597501

Page 66: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

ENter command

Journal command

MODify command

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

* No corresponding recording technique.

Media Types Recording Techniques

ENteracs-idlsm-idcap-id

00

SCRatchTLSM(lsm-id)

Journal Full( )ContinueABEND

FMODify

CONFIGRESET

lsm-id OFFline

LSMlsm-idlsm-range

( lsm-list,

)

ONlineOFFline

FORCE

CAP cap-id ONline

ADD ACSType( SL8500 )SL3000

DELete ACS(acs-id)

UPDate ACS(acs-id)

54 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 67: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

MONITOR command

Mount command

Media Types

LONGItud

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C

STK1, STK1R

STK2, STK2P

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

T10000T1, T10000TS

MNMONITOR PGMI

,L(ccname

)

Mount

volser devaddr

host-id,

Readonly

SCRTCH devaddrhost-id SUBpool(subpool-name)PRIVAT MEDia( media-type )

HSC Operator Command Syntax 55Rev. E, 5/31/09 - 312597501

Page 68: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Mount/Dismount Options (MNTD) command and control statement

MOVe command

MNTD AUtocln(ONOFf )

,

Manual

ACS(acs-id)

ACS(acsid)

Reply

Auto

HOSTID(host-id)

MSg

Dismount(

EJctauto( ON

OFf

Float(

Auto

ON

MAXclean(count)

Delete

)

)

)

)MMount(

PASSTHRU(count)

Scratch( Manual )

OFf

SCRDISM( CURRENT

ARCHIVE

)

MOVe Flsm(lsm-id) Panel(pp) Row(row-list)Column(cc)

Row(rr)Column(column-list)

Volume(vol-rangevolser

vol-list,

)

TLsm( )TPanel(pp)

lsm-id

lsm-list,

56 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 69: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

OPTion command and control statement

RECover Host command

RELease CAP command

OPTion Dialog( BothConsoleLog

)

,

HOSTID(host-id)

DISCmsg( SHowSUppress

)ACS(acs-id)

ENTdup(AutoManual )

Output( UpperMixed

)

Repath( YesNo

)

Reply

Viewtime(count)

Off

SEN( ON )

OFf

Warnmsg(minutes)

DUPOFL( ON

OFF

EJLimit(count)

ExtendedLOGging( Standard )

)

RECover host-idFORCE

RELease cap-id

HSC Operator Command Syntax 57Rev. E, 5/31/09 - 312597501

Page 70: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SENter command

SRVlev command

Stop Monitoring (STOPMN) command

SWitch command

SENter cap-id

SRVlev BASEFULL

STOPMNPM

PGMI,L(

ccname

)

SWitchAcs acs-id

(1)

Note:(1) ACS acs-id is optional in a single-ACS environment; it is required in a multiple-ACSenvironment.

58 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 71: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

TRace command

TRACELKP command

User Exit (UEXIT) command and control statement

TRacecomp-name

comp-list,

OFF comp-name

comp-list,

TRACELKP

table-name

table-list

,

OFF table-name

UEXIT nn

Enable

Load(name

SLSUXnn)

,Disable

,Enable

Disable

nnnn-range

( nn-list,

)

Query

HSC Operator Command Syntax 59Rev. E, 5/31/09 - 312597501

Page 72: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Vary Station command

VIew command

Vary

acs-rangeacs-id

OFFlineONline

FORCE

ACS

dev-idSTation

( acs-list,

)

dev-range

)( dev-list,

VIew CApCAPID(cap-id)Lsm(lsm-id)

CAPID(00:00:00)

CEllRow(rr)

Row(00)Lsm(00:00)

Lsm(lsm-id) Panel(pp)

Panel(00)

Column(cc)

Column(00)

Column(cc)

Column(00)

DRive Address(xxx)Host(host-id)

PLaygrndLsm(00:00)

Lsm(lsm-id) Column(cc)

Column(00)

PTpLsm(00:00)

Lsm(lsm-id) Xlsm(ll) Column(c)

Column(0)

Time(ttt)

Row(rr)

Row(00)

60 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 73: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Warn command

Media Types Recording Techniques

LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack

Standard

ECART

ZCART

DD3, DD3A, DD3B, DD3C HELical, DD3

STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5

STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35

LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W

*

* No corresponding recording technique.

SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4

*

T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35

Warn SCRatchlsm-idacs-id

SUBpool(subpool-name)THReshld(threshold-value)

MEDia( media-type ) RECtech( recording-technique,

)

HSC Operator Command Syntax 61Rev. E, 5/31/09 - 312597501

Page 74: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

62 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 75: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

HSC Diagnostic Command Syntax

This section contains the syntax for diagnostic commands. For complete descriptions of the commands, see the HSC System Programmer’s Guide and HSC Operator’s Guide.

HSC Diagnostic Command Syntax 63

Rev. E, 5/31/09 - 312597501

Page 76: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

LIst command

TRace command

LIST

length

control-block

?

offset+

length?

16

cb length

-

offset+

-

address

length?

50

offset+

-

LVT-label

TRacecomp-name

comp-list,

OFF comp-name

comp-list,

64 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501

Page 77: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information
Page 78: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

Printed in U.S.A.

Page 79: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information
Page 80: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information

SUN™ THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo are trademarks or registered trademarks of Sun Microsystems, Inc. in theUnited States and other countries.

Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com

ARGENTINA: 5411-4317-5636 • AUSTRALIA: 1-800-550-786 • AUSTRIA: 43-1-601-26-0 • BALKANS: 301-6188-111 • BELGIUM: 32 2-704 89 83 • BRAZIL: 55-11-51872100 • BRUNEI: 65-216-8333 • CANADA: 1-800-422-8020 (GENERAL); 416-964-2001 (LEARNING MANAGEMENT SYSTEM SALES,TORONTO) • CHILE: 562-372-4500 • COLOMBIA: 571-629-2323CZECH REPUBLIC: 420 2 33009311 • DENMARK: 45 4556 5040 • EGYPT: 00 202 570 9442 • FINLAND: 358-9-525-561 • FRANCE: 33-1-41-33-17-17 • GERMANY: 49-89-460-08-2788 • GREECE: 30-01-6188101 • HONG KONG: 852-2877-7077 • HUNGARY: 361-202-4415 • INDIA: 91-80-229-8989 • INDONESIA: 65-216-8333 • IRELAND: 353-1-668-4377ISRAEL: 972-9-9710500 • ITALY: 39-02-9259511 • JAPAN: 81-3-5779-1820 • KOREA: 82-2-3453-6602 • MALAYSIA: 603-2116-1887 • MIDDLE EAST: 00 9714 3366333 • MEXICO: 525-261-0344 • NETHERLANDS: 31-33-4515200 • NEW ZEALAND: 0800-786-338 • NORTH WEST AFRICA: 00 9714 3366333 • NORWAY: FROM NORWAY: 47-22023950, TO NORWAY:47-23369650 • PAKISTAN: 00-9714-3366333 • PEOPLE'S REPUBLIC OF CHINA: 8610-6803-5588 • PHILIPPINES: 632-885-7867 • POLAND: 48-22-8747848 • PORTUGAL: 351-21-413-4000 • RUSSIA: 7-095-935-8411 • SAUDI ARABIA: 00 9714 3366333 • SINGAPORE: 65-216-8300 • SOUTH AFRICA: 27-11-256-6300 • SPAIN: 34-902-210-412 • SRI LANKA:65-2168333 • SWEDEN: 46-8-631 22 00 • SWITZERLAND: 41-1-908-90-50 (GERMAN) 41-22-999-0444 (FRENCH) • TAIWAN: 886-2-25185735 • THAILAND: 662-344-6855 • TURKEY: 90 212 335 22 00 • UNITED KINGDOM: 44-1276-416-520 • UNITED STATES: 1-800-422-8020 • VENEZUELA: 582-905-3800 • VIETNAM: 65-216-8333 • WORLDWIDE

HEADQUARTERS: 1-650-960-1300