StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09...
Transcript of StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09...
![Page 1: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/1.jpg)
StorageTek™Host Software
MVS software
Reference SummaryPart Number: 312597501
Version: 6.1
Component (HSC)
Revision:E
![Page 2: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/2.jpg)
![Page 3: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/3.jpg)
Host Software Component(MVS Implementation)
Reference Summary
Release 6.1
312597501
![Page 4: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/4.jpg)
Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.
U.S. Government Rights - Commercial Software. Government users are subject to the Sun Microsystems, Inc. standard license agreement and applicable provisions of the FAR and its supplements.
Sun, Sun Microsystems, the Sun logo, Sun Fire and The Network Is The Computer are trademarks or registered trademarks of Sun Microsystems, Inc. or its subsidiaries, in the U.S. and other countries.
Products covered by and information contained in this service manual are controlled by U.S. Export Control laws and may be subject to the export or import laws in other countries. Nuclear, missile, chemical biological weapons or nuclear maritime end uses or end users, whether direct or indirect, are strictly prohibited. Export or reexport to countries subject to U.S. embargo or to entities identified on U.S. export exclusion lists, including, but not limited to, the denied persons and specially designated nationals lists is strictly prohibited.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, États-Unis. Tous droits réservés.
Droits du gouvernement des États-Unis. Logiciel Commercial. Les droits des utilisateur du gouvernement des États-Unis sont soumis aux termes de la licence standard Sun Microsystems et aux conditions appliquées de la FAR et de ces compléments.
Sun, Sun Microsystems, le logo Sun, Sun Fire et The Network Is The Computer sont des marques de fabrique ou des marques enregistrées de Sun Microsystems, Inc. ou ses filiales, aux États-Unis et dans d'autres pays.
Les produits qui font l'objet de ce manuel d'entretien et les informations qu'il contient sont regis par la legislation americaine en matière de contrôle des exportations et peuvent être soumis au droit d'autres pays dans le domaine des exportations et importations. Les utilisations finales , ou utilisateurs finaux, pour des armes nucleaires, des missiles, des armes biologiques et chimiques ou du nucleaire maritime, directement ou indirectement, sont strictement interdites. Les exportations ou reexportations vers des pays sous embargo des États-Unis, ou vers des entites figurant sur les listes d'exclusion d'exportation americaines, y compris, mais de maniere non exclusive, la liste de personnes qui font objet d'un ordre de ne pas participer, d'une façon directe ou indirecte, aux exportations de des produits ou des services qui sont regi par la legislation americaine sur le contrôle des exportations et la liste de ressortissants specifiquement designes, sont rigoureusement interdites.
LA DOCUMENTATION EST FOURNIE "EN L'ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITE MARCHANDE, À L'APTITUDE À UNE UTILISATION PARTICULIERE OU À L'ABSENCE DE CONTREFAÇON.
![Page 5: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/5.jpg)
Document Effectivity
EC Number Date Doc Kit Number Type Effectivity
132084 February, 2005 --- First Edition This document applies to the Host Software Component for MVS (MVS/HSC), Version 6.1.
132553 February, 2006 --- Revision B
--- April, 2008 --- Revision C
--- September, 2008 --- Revision D
--- May, 2009 --- Revision E
Document Effectivity iiiRev. E, 5/31/09 - 312597501
![Page 6: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/6.jpg)
iv HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 7: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/7.jpg)
Contents
About this Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Other HSC Books to Help You . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Syntax Flow Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Specifying Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Delimiters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Flow Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Single Required Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Single Optional Choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Repeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Syntax Continuation (Fragments) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Library Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5How to Specify a CAPid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CAPid Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Ranges and Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Control Statement Syntax Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
LIBGEN Macro Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SLIACS macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIALIST macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIDLIST macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIDRIVS macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLIENDGN macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SLILIBRY macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17SLILSM macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18SLIRCVRY macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18SLISTATN macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Utility Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
ACTivities Report utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22AUDIt utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22BACKup utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Database Decompile (LIBGEN) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Directory Rebuild (DIRBLD) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Contents vRev. E, 5/31/09 - 312597501
![Page 8: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/8.jpg)
EJECt utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24INITialize Cartridge utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Journal OFFLoad utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MERGEcds utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25MOVe utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Reconfiguration utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26REPLace utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26RESTore utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26SCRAtch utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Scratch Conversion utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Scratch Redistribution (SCREdist) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28SET utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29UNSCratch utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30UNSElect utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Volume Report (VOLRpt) utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Control Statement Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Control Data Set Definition (CDSDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34EXECParm control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Journal Definition (JRNDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34License Key Definition (LKEYDEF) command and control statement . . . . . . . . . . . . . . . . . . . . . 35License Key Information (LKEYINFO) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35LMUPATH control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35LMUPDEF command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35OPTion control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Reconfiguration Definition (RECDEF) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Scratch Subpool Definition (SCRPDEF) command and control statement . . . . . . . . . . . . . . . . . . 36Scratch Subpool (SCRPOol) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37User Exit command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Volume Attribute (VOLATTR) control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Volume Attribute Definition (VOLDEF) command and control statement . . . . . . . . . . . . . . . . . . 39
HSC Operator Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Allocation (ALLOC) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41CAP Preference (CAPPref) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41CDs Enable/Disable command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42CLean command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Communications Path (COMMPath) command and control statement . . . . . . . . . . . . . . . . . . . . . 43DISMount command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Display command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44DRAin CAP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52EJect command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53ENter command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Journal command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54MODify command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54MONITOR command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
vi HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 9: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/9.jpg)
Mount command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Mount/Dismount Options (MNTD) command and control statement . . . . . . . . . . . . . . . . . . . . . . . 56MOVe command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56OPTion command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57RECover Host command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57RELease CAP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57SENter command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58SRVlev command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Stop Monitoring (STOPMN) command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58SWitch command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58TRace command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59TRACELKP command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59User Exit (UEXIT) command and control statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Vary Station command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60VIew command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Warn command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
HSC Diagnostic Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
LIst command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64TRace command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Contents viiRev. E, 5/31/09 - 312597501
![Page 10: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/10.jpg)
viii HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 11: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/11.jpg)
About this Summary
This summary contains frequently used syntax information associated with Release 6.1.0 of the Host Software Component (MVS Implementation).
Use the material presented here as a memory aid. We assume that you are an experienced user who has worked with the Host Software Component at the programmer level. With this in mind, explanatory text has been kept to a minimum.
The following information appears in this reference summary:
• syntax conventions• LIBGEN macro syntax• control statement syntax• utility syntax • operator command syntax• diagnostic command syntax.
Other HSC Books to Help You
This summary supplements existing HSC 6.1.0 documentation. For more detailed information about a topic, refer to the following manuals:
• HSC Configuration Guide• HSC System Programmer’s Guide • HSC Operator’s Guide• HSC Messages and Codes Guide.
About this Summary ix
Rev. E, 5/31/09 - 312597501
![Page 12: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/12.jpg)
x HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 13: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/13.jpg)
Syntax Conventions
Syntax Flow Diagrams
Syntax is illustrated using flow diagrams. These can include the following elements:
• Syntax – the diagram itself.
• Items – individual elements inside the diagram. Items can be keywords, variables, delimiters, operators, fragment references, and separators.
• Groups – a collection of items or other groups.
The following sections describe syntax flow diagram features and include some generic examples.
Specifying Commands
Commands are composed of command names, keyword parameters, and positional parameters. Command names initiate command execution, keyword parameters are operands that contain keywords and their related values, and positional parameters are operands that are identified by their position in the command string rather than by keywords.
• Keyword parameters can be specified in any order. The HSC accepts (tolerates) multiple occurrences of a keyword. The value assigned to a keyword reflects the last occurrence of a keyword within a command.
• Positional parameters must be entered in the order shown in the syntax diagram.
• Uppercase letters indicate the minimum abbreviation for the command name, keyword, or positional parameter.
Variables
Variables are italicized.
Delimiters
If a comma(,), a semicolon(;), or other delimiter is shown with an element of the syntax diagram, it must be entered as part of the statement or command.
Syntax Conventions 1
Rev. E, 5/31/09 - 312597501
![Page 14: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/14.jpg)
Flow Lines
Syntax diagrams consist of horizontal and vertical lines and the text of a command, control statement, macro, or utility.
or
Diagrams are read left to right and top to bottom. Arrows show flow and direction.
• a statement begins with
• a statement ends with
• diagrams continuing to the next line begin with
• fragments begin and end with |
Single Required Choice
Branch lines, without repeat arrows, indicate that a single choice must be made. If one of the items from which a choice is being made is on the base line of the diagram, a single choice is required.
COMMAND/MACRO/UTILITY
Item1Item2Item3
COMMAND/UTILITY NAME
Item3(variable5)
Item1(variable1) Item2( variable2variable3variable4
)
Item1Item2Item3
2 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 15: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/15.jpg)
Single Optional Choice
If the first item is on the line below the base line, a single choice of items in the stack is optional.
Defaults
Default values and parameters appear above the syntax diagram line. In the following example, if a value is not specified with the command, Default Value is used by the HSC.
Some keyword parameters provide a choice of values in a stack. When the stack contains a default value, the keyword and the value choices are placed below the baseline to indicate that they are optional, and the default value appears above the keyword line. In the following example, if the keyword is not specified with the command, Keyword(Default Value) is used by the HSC.
Repeat Symbol
A repeat symbol indicates that more than one choice can be made or that a single choice can be made more than once. The repeat symbol shown in this example indicates that a comma is required as the repeat separator.
Item3
Item1Item2
Value2Value3
Default Value
Keyword
Value3
Default ValueValue2
,variable
Syntax Conventions 3Rev. E, 5/31/09 - 312597501
![Page 16: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/16.jpg)
Syntax Continuation (Fragments)
Fragment references direct you to parts (fragments) of the syntax that contain more detail than can be shown in the main syntax diagram.
COMMAND/UTILITY NAME Fragment Reference
Item1(
Fragment:
variable2,variable1
variable4variable3 )
Item2(variable6
,variable5variable8variable7 )
4 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 17: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/17.jpg)
Library Identification
Each ACS, LSM, and CAP is assigned a unique identification number during LIBGEN. Use this number in HSC commands and utilities when identifying a specific ACSid, LSMid, or CAPid.
• ACSid (acs-id) is a hexadecimal value from 00 through FF that identifies the LMU.
An acs-id is the result of defining the SLIALIST macro during a LIBGEN. See “LIBGEN Macros” in the HSC Configuration Guide for information about the SLIALIST macro. The first ACS listed in this macro acquires a hexadecimal identifier of 00, the second ACS listed acquires a hexadecimal identifier of 01, and so forth until all ACSs are identified.
• An LSM number (ll) is a hexadecimal value from 00 through 17. It differentiates an LSM from every other LSM connected to the same LMU.
An LSM number is the result of defining the SLIACS macro LSM parameter. See the HSC Configuration Guide for information about the SLIACS macro. The first LSM listed for an ACS acquires a hexadecimal number of 00, the second LSM listed for an ACS acquires a hexadecimal number of 01, and so forth.
• An LSMid (lsm-id) is made up of the ACSid and the LSM number separated by a colon (:). It differentiates an LSM from every other LSM in a library.
• A CAP number is a hexadecimal value from 00 to 02 for all existing libraries, except for SL3000 libraries. The CAP number for an SL3000 is a hexadecimal value from 00 to 0B. The CAP number identifies a specific CAP in an LSM that has more than one CAP.
• A CAPid (cap-id) is a hexadecimal value made up of the LSMid and the CAP number separated by a colon. Refer to “How to Specify a CAPid” on page 6 for more information.
Some HSC commands and utilities require, or optionally allow, the user to specify a host identifier or a VOLSER.
• The host-id for a given host is the identifier specified in the HOSTID parameter of the SLILIBRY macro in the LIBGEN. The HOSTID parameter is the SMF system identifier for both JES2 and JES3. Valid characters for a HOSTID are A-Z, 0-9, #, $ and @.
• A VOLSER (volser) identifies a volume serial number consisting of one to six characters. Valid characters are A-Z, 0-9, # (crosshatch), $, ¥ (yen character), and optional trailing blanks. Leading blanks are not allowed.
Syntax Conventions 5Rev. E, 5/31/09 - 312597501
![Page 18: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/18.jpg)
How to Specify a CAPid
A CAPid specifies a particular CAP in the library. Each CAP is identified by the LSMid of the LSM that the CAP is attached to and a CAP number to distinguish it from other CAPs in that LSM.
CAP configurations differ based on the LSM type. The following configurations are possible:
LSM (Model 4410) and PowderHorn LSM (Model 9310) can be configured with either the standard 21-cell CAP or an enhanced CAP. An enhanced CAP contains two 40-cell magazine-style CAPs and a one-cell priority CAP (PCAP). The 40-cell CAPs function independently.
WolfCreek LSM (Models 9360-050, 9360-075, and 9360-100) configured with a WolfCreek CAP which contains a 20-cell magazine-style CAP and a PCAP. An optional 30-cell, magazine-style CAP, called a WolfCreek optional CAP, may be added to the WolfCreek CAP.
TimberWolf LSM (Model 9740) configured with either a 14-cell permanent rack or a 10-cell removable magazine.
StreamLine Library (Model SL3000) The library is configured with 2, 13-cell removable magazines in each CAP. This library can contain up to 12 CAPs (00-0B).
StreamLine Library (Model 8500)This library is configured with 3, 13-cell removable magazines. An optional 39-cell CAP can be added.
6 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 19: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/19.jpg)
CAPid Formats
There are two formats that can be used to specify a CAPid:
• AA:LL, where AA is the ACSid and LL is the LSM number. This format is referred to as the lsm-id.
• AA:LL:CC, where AA:LL is the LSMid and :CC is the CAP number. This format is referred to as the cap-id.
Caution: Do not use a colon as the MVS command delimiter because the system will process the colon in the new CAPid format as the end of the command. All information following the colon in an HSC command will not be processed.
The appropriate format to use is determined by the CAP hardware and the command being specified.
• The AA:LL format can be specified in the following situations:
- to specify a standard CAP - to allow the HSC to select a CAP based on CAP preference.
• The AA:LL:CC format can be specified for any CAP hardware in any command that accepts a CAPid. This is the preferred format. Valid CAP numbers are:
00 indicates one of the following:
• a 21-cell 4410 or 9310 standard CAP• the right-hand 40-cell 4410 or 9310 enhanced CAP• the 20-cell 9360 WolfCreek CAP• a 14-cell or 10-cell removable magazine 9740 TimberWolf CAP• a left-side SL3000 AEM CAP, consisting of 18, 13-cell removable magazines • the left-hand 39-cell SL8500 library CAP.
01 indicates one of the following:
• the left-hand 40-cell 4410 or 9310 enhanced CAP• the 30-cell 9360 WolfCreek optional CAP• an optional SL3000 CEM CAP consisting of 2, 13-cell removable magazines• the right-hand optional 39-cell SL8500 library CAP.
02 indicates one of the following:
• PCAP in either a 4410 or 9310 enhanced CAP or a 9360 WolfCreek CAP.• an optional SL3000 CEM CAP consisting of 2, 13-cell removable magazines.
03, 04, 05 indicates the following:
• an optional SL3000 CEM/DEM CAPs each consisting of 2, 13-cell removable magazines.
Syntax Conventions 7Rev. E, 5/31/09 - 312597501
![Page 20: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/20.jpg)
06 indicates the following:
• the only required SL3000 BDM CAP consisting of 2, 13-cell removable magazines.
07, 08, 09, 0A indicates the following:
• an optional SL3000 CEM CAPs each consisting of 2, 13-cell removable magazines.
0B indicates the following:
• a right-side SL3000 AEM CAP, consisting of 18, 13-cell removable magazines
Notes:
• If SL3000 library CAPs are not present, the HSC reports them as “not installed” This keeps CAP addresses from changing as new CAPs are added.
• Refer to the individual command explanations for additional information on specifying CAPids.
• SL3000 and SL8500 libraries do not contain a PCAP.
8 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 21: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/21.jpg)
Ranges and Lists
HSC commands and utilities often allow the user to specify ranges and lists of elements.
1. An inclusive range is indicated by a pair of elements of the same length and data type, joined by a dash. The first element must be strictly less than the second element.
• A hexadecimal range consists of a pair of hexadecimal numbers (for example, 0A2-0AD, or 000-0FC).
• A decimal range consists of a pair of decimal numbers (for example, 1-9, or 010-094). Leading zeros are not required.
• A numeric VOLSER range (vol-range) consists of a pair of VOLSER elements containing a decimal numeric portion of 1 to 6 digits (for example, ABC012-ABC025, or X123CB-X277CB). The decimal portion is referred to as an incremental range. The following additional restrictions apply:
- The character positions of the incremental portion of both range elements must match.
- The non-incremental characters of the first element must be identical to those of the second element.
- You cannot increment two portions of a range element. If 111AAA is the first element, you cannot specify 112AAB for the second element.
- If a VOLSER range contains more than one decimal portion, any portion is valid as the incremental range. For example:
Note: A VOLSER range for most operator commands is limited to 100 entries. If a larger range is entered, only the first 100 VOLSERs in the range are acted on. If HSC utilities are used, the entire range is processed.
• An alphabetic VOLSER range (vol-range) consists of a pair of VOLSER elements containing an incremental portion of 1 to 6 characters (for example, 000AAA-000ZZZ, or 9AAA55-9ZZZ55). This portion is referred to as an incremental range. The following additional restrictions apply:
- The character positions of the incremental portion of both range elements must match.
- The non-incremental characters of the first element must be identical to those of the second element.
A00B00 the largest range that can be specified is A00B00 through A99B99.
A0B0CC the largest range that can be specified is A0B0CC through A9B9CC.
000XXX the largest range that can be specified is 000XXX through 999XXX.
Syntax Conventions 9Rev. E, 5/31/09 - 312597501
![Page 22: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/22.jpg)
- You cannot increment two portions of a range element. If 111AAA is the first element, you cannot specify 112AAB for the second element.
- The alphabetic portion of the VOLSER range is defined as being from character A to Z. To increment multi-character sequences, each character increments to Z. For instance, ACZ is part of the AAA-AMM range. Examples are:
The number of volumes in an alphabetic VOLSER range depends on the number of elements in the incrementing portion of the VOLSER range. For an A to Z range in each character position, the number of volumes can be calculated by 26 to the power of the number of positions that are being incremented.
Note: For most operator commands, a VOLSER range is limited to 100 entries. If a large range is entered, only the first 100 VOLSERs are acted upon. If HSC utilities are used, the entire range is processed.
A00A0-A99A0 increments VOLSERs A00A0 through A09A0, then A10A0 through A99A0.
9AA9A-9ZZ9A increments VOLSERs 9AA9A through 9AZ9A, then 9BA9A through 9ZZ9A.
111AAA-111ZZZ increments VOLSERs 111AAA through 111AAZ, then 111ABA through 111ZZZ.
999AM8- 999CM8 increments VOLSERs 999AM8 through 999AZ8, then 999BA8 through 999CM8
A3BZZ9- A3CDE9 increments VOLSERs A3BZZ9 through A3CAA9, then A3CAB9 through A3CDE9
AAAAAA-AAACCC
increments VOLSERs AAAAAA through AAAAAZ, then AAAABA through AAACCC
CCCNNN-DDDNNN
increments VOLSERs CCCNNN through CCCNNZ, then CCCNOA through DDDNNN*
* Caution: This is a very large range.
A-Z 261 26
AA-ZZ 262 676
AAA-ZZZ 263 17,576
AAAA-ZZZZ 264 456,976
AAAAA-ZZZZZ 265 11,881,376
AAAAAA-ZZZZZZ 266 308,915,776
10 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 23: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/23.jpg)
2. A list consists of one or more elements. If more than one element is specified, the elements must be separated by a comma or a blank, and the entire list enclosed in parentheses.
• For some HSC operator commands, an element may consist of a single item or a range. Refer to the individual command explanations for valid list entries.
• In general, HSC utilities do not allow ranges to be specified in a list. The exception to this is a VOLSER list (vol-list) which does allow ranges to be specified.
For VOLATTR control statements, you can use wildcard characters (%, ?, or *) to identify a list of VOLSERs.
Syntax Conventions 11Rev. E, 5/31/09 - 312597501
![Page 24: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/24.jpg)
Control Statement Syntax Conventions
The control statement for each utility program consists of a command (indicating the utility function) followed by parameters, as applicable, in 80-character card-image records. The standard syntax conventions for control statements are as follows:
• The only valid control statement information area is from column 2 to column 72. Columns 73-80 are ignored.
• Parameters are separated by one or more blanks or a comma.
• A value is associated with a parameter by an equal sign (=) or by enclosing the value in parentheses, and concatenating it immediately after the parameter.
• Case (upper or lower) is ignored in actual control statements.
• Control statements may be interspersed with comments designated by an asterisk (*) in column one.
For definition data sets (VOLATTRs, UNITATTRs and TAPEREQs) comments must be in the new format (/*...*/). Asterisk (*) comments are not allowed. A /*...*/ comment in the first line is not required for definition data sets.
• A control statement is terminated if the statement is not continued. Control statements must have a /*...*/ comment as the first control statement in the PARMLIB member. A PARMLIB member that does not begin with a /*...*/ style comment is assumed to be in the old format. Comments in old format members must begin with an asterisk in column 1.
In contrast to utility control statements, PARMLIB control statements may begin in column 1. Columns 73-80 are ignored.
To allow for continuation, comments in the job stream must start with /* and end with */. Comments cannot be nested, and mixing the two comment styles (* and /*) is not allowed.
• The 80-character card-image records use conventional continuation rules.
- A space and a dash (–) following a parameter or parameter value indicates that a blank is to be inserted between the last nonblank character of this line and the first nonblank character of the next nonblank record.
- A plus sign (+) specifies that the continued control information is to be concatenated directly after the character preceding the plus sign. The continued data starts at column two of the next nonblank record.
Note: You can use a continuation only after a new keyword or after the natural end of a value. Some examples follow.
12 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 25: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/25.jpg)
The following examples illustrate continuations used correctly:
SCRPOOL NAME=STD36,RANGE+ (AAA000-AAA999,ZZZ000-ZZZ999)
SCRPOOL NAME=STD36,RANGE(AAA000-AAA999,- ZZZ000-ZZZ999)
The following example illustrates a continuation used incorrectly:
SCRPOOL NAME=STD36,RANGE(AAA000-AAA999,ZZZ+ 000-ZZZ999)
- Users must enter a nonblank character in column 72 (e.g., an X).
- PARMLIB control statements can be continued using the preceding continuation rules only if they are new format control statements.
• The maximum length of a control statement is 32,767 characters.
• The maximum length of a command (used as a command or in PARMLIB) is 126 characters.
Syntax Conventions 13Rev. E, 5/31/09 - 312597501
![Page 26: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/26.jpg)
14 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 27: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/27.jpg)
LIBGEN Macro Syntax
This section contains the syntax for LIBGEN macros presented in alphabetical order. For complete descriptions of the macros and the required order for specifying them, see the HSC Configuration Guide.
LIBGEN Macro Syntax 15
Rev. E, 5/31/09 - 312597501
![Page 28: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/28.jpg)
SLIACS macro
SLIALIST macro
SLIDLIST macro
SLIDRIVS macro
SLIENDGN macro
acs0 SLIACS Additional Parameters
Additional Parameters:
ACSDRV=(esoteric0, ...,esoteric15)
,STATION=(station0, ...,station15),LSM=(lsm0,lsm1, ...,lsm23)
,FUTRLSM=(8500,lsmnum)
acslist SLIALIST acs0, acs1,.....acs255
drvelst0 SLIDLIST HOSTDRV= (drives0,...,drives15)
drives0 SLIDRIVS ADDRESS=(addr0,addr1...)
SLIENDGN
16 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 29: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/29.jpg)
SLILIBRY macro
SLILIBRY HOSTID=(host-id0,host-id1,...,host-id15) ,ACSLIST=acslist
Optional Parameters
Optional Parameters:
,CLNPRFX= prefixCLN
,SMF= libtype255
,MAJNAME= qnameSTKALSQN
,COMPRFX= commandchar.
,SCRLABL=NLNSL
SLAL
,EJCTPAS=password ,DRVHOST=(host-id) FUTRACS=(x,y)
LIBGEN Macro Syntax 17Rev. E, 5/31/09 - 312597501
![Page 30: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/30.jpg)
SLILSM macro
SLIRCVRY macro
S (ptppanel8, SM
)) ,ADJACNT=(lsm1,...,lsm4)
,DOOR= STD,WINDOW=(wndpanel0,...,wndpanel3)
100
TYPE=441093109360
075050
,
-
9740
SLILSMlsm0
,PASTHRU=((ptppanel0,M
),...,
WC1ECAP
WC28500-1
8500-2
8500
,DRVELST=(drvelst0,...,drvelst3)DRIVE=(drvpanel0,...,drvpanel3)
3000
3000
labelSLIRCVRY
TCHNIQE=BOTHNONESHADOW
STANDBYALL
JOURNAL
18 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 31: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/31.jpg)
SLISTATN macro
station0 SLISTATN ADDRESS=(addr0,...,addr15)
LIBGEN Macro Syntax 19Rev. E, 5/31/09 - 312597501
![Page 32: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/32.jpg)
20 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 33: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/33.jpg)
Utility Syntax
This section contains the syntax for library utilities. For complete descriptions of the utilities, see the HSC System Programmer’s Guide.
Utility Syntax 21
Rev. E, 5/31/09 - 312597501
![Page 34: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/34.jpg)
ACTivities Report utility
AUDIt utility
ACTIvitiesOptional Parameters
Optional Parameters:
BEGIN( begin-dateTODAY
, begin-time00:00:00
END( end-dateTODAY
end-time23:59:59
)
),
AUDIt
Optional Parameters
Optional Parameters:
ACS(acs-id)ALL
APPLy( NO )YES
LSM(lsm-list)PANel(panel-list)
ROW(row-list)COLumn(column-list)
CAP(cap-id) DIAGScan( )ONLYEMPTYCelALSO
INTRANs
22 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 35: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/35.jpg)
BACKup utility
Database Decompile (LIBGEN) utility
Directory Rebuild (DIRBLD) utility
BACKupCDS(
PrimarySecondarySTandby
)
OPTion(RestartAnalyzeCopy
)
LIBGEN
DIRBLD
Utility Syntax 23Rev. E, 5/31/09 - 312597501
![Page 36: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/36.jpg)
EJECt utility
Media Types Recording Techniques
Standard 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
* No corresponding recording technique.
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
EJECt Eject Method 1
Eject Method 2CAP( cap-list )
,
Eject Method 1:
Eject Method 2:
VOLser( vol-list
,
)
SCRTCH
SUBpool(subpool-name) VOLCNT(count)
MEDia( media-type ) RECtech( recording-technique )
SEQ(YESNO )
24 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 37: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/37.jpg)
INITialize Cartridge utility
Journal OFFLoad utility
MERGEcds utility
INITializeOptional Parameters
Optional Parameters:
CAP(cap-id)
PROGram( prog-nameIEHINITT
) VERIFY(parameter-name)
CNTLDD( dd-name
SYSIN)
OPTion( EJEctSCRatch
)
OFFLoad
MERGEcdsVALIDate ALL
Utility Syntax 25Rev. E, 5/31/09 - 312597501
![Page 38: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/38.jpg)
MOVe utility
Reconfiguration utility
REPLace utility
RESTore utility
MOVe Parameters
Parameters:
Flsm(lsm-id) Panel(panel-list)
Volume(vol-list)
Row(row-list)Column(column-list)
TLsm(lsm-list)TPanel(panel)
STARTS
reconfig-procname
REPLaceall
VOLser( vol-list,
)
RESTore
APPly( NO ) GENerate(OnlyShort
YESNO
)YES
26 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 39: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/39.jpg)
SCRAtch utility
Scratch Conversion utility
SCRAtch VOLser( vol-list,
)
PARM= 'Optional Parameters
'
Optional Parameters:
TLMSRMM
,TMS
SCRPOOL(
,
NSLAL
NL
SUL
SL)
TODAYyyddd1
-yyddd2yyyyddd1
-yyyyddd2
190000100001
,
MIXED,
LIBONLY,
SMC
Utility Syntax 27Rev. E, 5/31/09 - 312597501
![Page 40: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/40.jpg)
Scratch Redistribution (SCREdist) utility
Media Types Recording Techniques
LONGItud, Standard LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
* No corresponding recording technique.
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
SCREdist ACS(acs-id)
LSM( lsm-list,
)SUBpool(subpool-name)
BALtol(tolerance-value) media-type )MEDia(
recording-technique )RECtech(
28 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 41: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/41.jpg)
SET utility
SET Options
Options:
ACSDRV(esoteric) ,FORACS(acs-id),FORHOST(host-id)
CLNPRFX(prefix)
COMPRFX(cmdhex)
DELDISP( SCRTCHNOSCRTCH
)
HOSTID(newhost),FORHOST(oldhost)
HSCLEVEL(OFF),FORHOST(host-id)
MAJNAME(qname)
FREEZE( ON )OFf
,FORLSMID(lsm-id)
EJCTPAS(newpswd
),OLDPASS(oldpswd)
NNLBDRV(
esoteric
)
,FORHOST(host-id)
SCRLABL( )SL
AL
NL
NSL
NEWHOST(newhost),LIKEHOST(model-host)
host-idOFF )DRVHOST(
,FORPANEL(panel)
Utility Syntax 29Rev. E, 5/31/09 - 312597501
![Page 42: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/42.jpg)
SET utility (continued)
UNSCratch utility
UNSElect utility
SET Options
Options:
SMF(libtype)
TCHNIQE(
JOURNALSHADOWBOTHSTANDBYALL
NONE )
SLIDRIVS(addr0
,...addr31
),FORLSMID(lsm-id),FORPANEL(panel)
,FORHOST(host-id)
SLISTATN(stat1,...,stat16
),FORACS(acs-id),FORHOST(host-id)
UNSCratch VOLser( vol-list,
)
UNSElect VOLser(volser),FORCE
30 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 43: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/43.jpg)
Volume Report (VOLRpt) utility
VOLRptACS(acs-id)
LSM( lsm-list,
)
VOLser ( volservol-range
vol-list,
)
VOLume ( volservol-range
vol-list,
)
SORT(LOCINSVOL
SELUSE
)DEScend
ASCend
INCLude(
,*SCRNONSCRERR
NONERRSEL
NONSELREADable
UNREADableMEDEQUAL
NONMEDEQ
)EXCLude(
,SCRNONSCRERR
NONERRSEL
NONSELREADable
UNREADableMEDEQUAL
NONMEDEQ
)
NOEXTernalNOEXTernal
VOLDATA
VOLIST
CDSDATA SUMMary( TOTalSUBpoolTOTal,SUBpool
)
NOSORT
Utility Syntax 31Rev. E, 5/31/09 - 312597501
![Page 44: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/44.jpg)
32 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 45: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/45.jpg)
Control Statement Syntax
This section contains the syntax for control statements. For complete descriptions of the control statements, see the HSC System Programmer’s Guide.
Control Statement Syntax 33
Rev. E, 5/31/09 - 312597501
![Page 46: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/46.jpg)
Control Data Set Definition (CDSDEF) control statement
EXECParm control statement
Journal Definition (JRNDEF) control statement
CDSDEF DSN1(dataset.name),VOL1(volser),UNIT1(unitname)
,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)
,DSN3(dataset.name),VOL3(volser),UNIT3(unitname) ,DISABLE
EXECParm
MSGPRFX( NoYes
),Eid(gtfeid) ,Fid(gtffid)
,HOSTID(host-id)
,VOL1(volser),UNIT1(unitname)
,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)
,FULL(AbendContinue )
,HOSTID(host-id)
DSN1(dataset.name)JRNDEF
34 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 47: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/47.jpg)
License Key Definition (LKEYDEF) command and control statement
License Key Information (LKEYINFO) control statement
LMUPATH control statement
LMUPDEF command and control statement
DATASET(dataset.name)DSN(dataset.name) VOLume(volser)
LKEYDEF
UNIT(unitname) HOSTID(host-id)
LKEYINFO PRODuct(product_identifier) CUSTomer('customer_name')
SITEno(nnnnnnn) EXPRdate(yyyyddd) KEY(license_key_string)
,ACS(aa) LMUADDR(LMUPATH
lmu_hostnamennn.nnn.nnn.nnn
) PARTID(00n)
LMUPDEFDSN(dataset.name)
DATASET(dataset.name)VOLume(volser) UNIT(unitname)
HOSTID( host-id,
)
Control Statement Syntax 35Rev. E, 5/31/09 - 312597501
![Page 48: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/48.jpg)
OPTion control statement
Reconfiguration Definition (RECDEF) control statement
Scratch Subpool Definition (SCRPDEF) command and control statement
OPTion TITLE(identifying-string)TRACETRACEF
RECDEF DSN1(dataset.name),VOL1(volser),UNIT1(unitname)
,DSN2(dataset.name),VOL2(volser),UNIT2(unitname)
SCRPDEFDSN(dataset.name)
DATASET(dataset.name)VOLume(volser) UNIT(unitname)
HOSTID( host-id,
)
36 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 49: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/49.jpg)
Scratch Subpool (SCRPOol) control statement
User Exit command and control statement
SCRPOol NAME(subpool-name) subpool-range )
,HOSTID(ALLhost-id
host-list,
,RANGE(
,
) ,LABEL( SLNLALNSL
UEXIT nn
Enable
Load(name
SLSUXnn)
,Disable
,Enable
Disable
nnnn-range
( nn-list,
)
Query
Control Statement Syntax 37Rev. E, 5/31/09 - 312597501
![Page 50: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/50.jpg)
Volume Attribute (VOLATTR) control statement
Media Types Recording Techniques
LONGItud, Standard LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
ECART
ZCART
DD3A, DD3B, DD3C, DD3D HELical, DD3
STK1R, STK1U, STK1Y STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2P STK2W STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
* No corresponding recording technique.
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS, T10000CT T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
VOLATTR SERial( volservol-range
vol-list,
)MEDia( media-type )
RECtech( ) MAXclean(use-limit)recording-technique
38 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 51: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/51.jpg)
Volume Attribute Definition (VOLDEF) command and control statement
VOLDEFDSN(dataset.name)
DATASET(dataset.name)VOLume(volser) UNIT(unitname)
HOSTID( host-id,
)
Control Statement Syntax 39Rev. E, 5/31/09 - 312597501
![Page 52: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/52.jpg)
40 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 53: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/53.jpg)
HSC Operator Command Syntax
This section contains the syntax for operator commands. For complete descriptions of the commands, see the HSC Operator’s Guide.
Allocation (ALLOC) command and control statement
CAP Preference (CAPPref) command and control statement
ALLOCHOSTID(host-id)
,
LOWscr( NONE )
COUNT )
LSMpref(
9360
44109310
NONE )
SCRtech(
ANY
ROTATE
CAPPref prefvlue lsm-idcap-idcap-range
( cap-list,
)
host-id AUTOMANual
HSC Operator Command Syntax 41
Rev. E, 5/31/09 - 312597501
![Page 54: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/54.jpg)
CDs Enable/Disable command
CLean command
PrimarySEcndrySTandby
DSn(dsn)Disable
DSn(dsn)CDs EnableNEWVol(volser),NEWUnit(unitname)NEWLoc
EXpand
CLeandev-rangedev-id
( dev-list,
)
host-id
42 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 55: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/55.jpg)
Communications Path (COMMPath) command and control statement
DISMount command
COMMPath HOSTid(host-id)
METHod(LMUCDS
LMU,acs-idVTAM
)LMUpath( acs-id
acs-range
acs-list,
) VTAMpath(name)
LMUpath( acs-idacs-range
acs-list,
)VTAMpath(name)
VTAMpath(name)
DELete
LMUpath( acs-idacs-range
acs-list,
)VTAMpath
(name)
VTAMpath(name)
DISMountvolser, devaddr
host-id
HSC Operator Command Syntax 43Rev. E, 5/31/09 - 312597501
![Page 56: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/56.jpg)
Display command
Display Acs
Display ALl
Display ALLOC
Display Cap
Display CDS
Displayacs-id
Acs
( acs-list,
)
acs-range
Display ALl
Display ALLOC
Display(all CAPs)
Capacs-idlsm-idcap-id
Display CDS
44 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 57: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/57.jpg)
Display Cmd
Display COMMPath
Display command-nameCOmmandCMd
Display COMMPath
HOSTid( ALLhost-id
*
,host-list
)
HSC Operator Command Syntax 45Rev. E, 5/31/09 - 312597501
![Page 58: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/58.jpg)
Display DRives
Media Types Recording Techniques Model Types
LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
4480, 4490, 9490, 9490EE
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C, DD3D HELical, DD3 SD3
STK1, STK1R, STK1U, STK1Y STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
9840, 984035, T9840B, T984035B, T9840C, T9840C35, T9840D, T9840D35, T9840DE, T9840DE5
STK2, STK2P, STK2W STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
T9940A, T9940A35, T9940B, T9940B35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W, LTO-CLN1, LTO-CLN2, LTO-CLNU
* HP-LTO2, HP-LTO3, HP-LTO4, IBM-LTO2, IBM-LTO3, IBM-LTO4
Display DRivesLibraryACS(acs-id)
LSM(lsm-id)
DETail ) )
Unit( unit-addressunit-address range
)
RECtech( recording-technique
)MODel( model-type
MEDia( media-type
BYDrive
BYLoc
ACtiveIdle
ALl
46 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 59: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/59.jpg)
Display Exceptions
Display LKEYDEF
Display LMUPDEF
Display LSM
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
* SDLT-600, DLT-S4
T10000T1, T10000TS, T10000CT T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
T1A34, T1A35, T1AE34, T1AE35, T1B34, T1B35, T1BE34, T1BE35
* No corresponding recording technique.
Media Types Recording Techniques Model Types
Display EXceptnsX
Display LKEYDEF
Display LMUPDEF
Display Lsmlsm-idlsm-range
(,lsm-list )
HSC Operator Command Syntax 47Rev. E, 5/31/09 - 312597501
![Page 60: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/60.jpg)
Display Message
Display MNTD
Display MONitor
Display OPTion
Display Requests
Display MessageMsg
msgnum
Display MNTD
Display MONitor,PGMI ,L(
namecc )
Display OPTion
Display Requests
48 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 61: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/61.jpg)
Display SCRatch
Media Types Recording Techniques
LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
* No corresponding recording technique.
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
Display SCRatchacs-idlsm-id
SUBpool(subpool-name) DETail
MEDia( media-type ) RECtech( recording-technique )
ALL
HSC Operator Command Syntax 49Rev. E, 5/31/09 - 312597501
![Page 62: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/62.jpg)
Display SCRPDEF
Display SRVlev
Display Status
Display THReshld
Media Types Recording Techniques
LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
Display SCRPDEF
Display SRVlev
Display Status
Display THReshldSUBpool(subpool-name) DETail
MEDia( media-type ) RECtech( recording-technique )
acs-idlsm-id
50 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 63: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/63.jpg)
Display TREQDEF
Display UNITDEF
Display VOLDEF
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
* No corresponding recording technique.
Media Types Recording Techniques
Display TREQDEF
Display UNITDEF
Display VOLDEF
HSC Operator Command Syntax 51Rev. E, 5/31/09 - 312597501
![Page 64: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/64.jpg)
Display Volume
DRAin CAP command
DisplayVolumeVolser
vol-rangevolser
( vol-list,
)
DETail
DRAin cap-idEJect
ENter
( )cap-list,
52 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 65: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/65.jpg)
EJect command
Media Types Recording Techniques
LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
EJect
Option 2
Option 1
Option 1:
vol-rangevolser
( vol-list,
)
acs-idlsm-idcap-id
( cap-list ),
SCRTCHacs-idlsm-idcap-id
( cap-list ),
SUBpool(subpool-name) VOLCNT(count
Option 2:
MEDia( media-type ) recording-technique )RECtech(
)
HSC Operator Command Syntax 53Rev. E, 5/31/09 - 312597501
![Page 66: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/66.jpg)
ENter command
Journal command
MODify command
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
* No corresponding recording technique.
Media Types Recording Techniques
ENteracs-idlsm-idcap-id
00
SCRatchTLSM(lsm-id)
Journal Full( )ContinueABEND
FMODify
CONFIGRESET
lsm-id OFFline
LSMlsm-idlsm-range
( lsm-list,
)
ONlineOFFline
FORCE
CAP cap-id ONline
ADD ACSType( SL8500 )SL3000
DELete ACS(acs-id)
UPDate ACS(acs-id)
54 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 67: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/67.jpg)
MONITOR command
Mount command
Media Types
LONGItud
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C
STK1, STK1R
STK2, STK2P
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
T10000T1, T10000TS
MNMONITOR PGMI
,L(ccname
)
Mount
volser devaddr
host-id,
Readonly
SCRTCH devaddrhost-id SUBpool(subpool-name)PRIVAT MEDia( media-type )
HSC Operator Command Syntax 55Rev. E, 5/31/09 - 312597501
![Page 68: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/68.jpg)
Mount/Dismount Options (MNTD) command and control statement
MOVe command
MNTD AUtocln(ONOFf )
,
Manual
ACS(acs-id)
ACS(acsid)
Reply
Auto
HOSTID(host-id)
MSg
Dismount(
EJctauto( ON
OFf
Float(
Auto
ON
MAXclean(count)
Delete
)
)
)
)MMount(
PASSTHRU(count)
Scratch( Manual )
OFf
SCRDISM( CURRENT
ARCHIVE
)
MOVe Flsm(lsm-id) Panel(pp) Row(row-list)Column(cc)
Row(rr)Column(column-list)
Volume(vol-rangevolser
vol-list,
)
TLsm( )TPanel(pp)
lsm-id
lsm-list,
56 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 69: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/69.jpg)
OPTion command and control statement
RECover Host command
RELease CAP command
OPTion Dialog( BothConsoleLog
)
,
HOSTID(host-id)
DISCmsg( SHowSUppress
)ACS(acs-id)
ENTdup(AutoManual )
Output( UpperMixed
)
Repath( YesNo
)
Reply
Viewtime(count)
Off
SEN( ON )
OFf
Warnmsg(minutes)
DUPOFL( ON
OFF
EJLimit(count)
ExtendedLOGging( Standard )
)
RECover host-idFORCE
RELease cap-id
HSC Operator Command Syntax 57Rev. E, 5/31/09 - 312597501
![Page 70: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/70.jpg)
SENter command
SRVlev command
Stop Monitoring (STOPMN) command
SWitch command
SENter cap-id
SRVlev BASEFULL
STOPMNPM
PGMI,L(
ccname
)
SWitchAcs acs-id
(1)
Note:(1) ACS acs-id is optional in a single-ACS environment; it is required in a multiple-ACSenvironment.
58 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 71: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/71.jpg)
TRace command
TRACELKP command
User Exit (UEXIT) command and control statement
TRacecomp-name
comp-list,
OFF comp-name
comp-list,
TRACELKP
table-name
table-list
,
OFF table-name
UEXIT nn
Enable
Load(name
SLSUXnn)
,Disable
,Enable
Disable
nnnn-range
( nn-list,
)
Query
HSC Operator Command Syntax 59Rev. E, 5/31/09 - 312597501
![Page 72: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/72.jpg)
Vary Station command
VIew command
Vary
acs-rangeacs-id
OFFlineONline
FORCE
ACS
dev-idSTation
( acs-list,
)
dev-range
)( dev-list,
VIew CApCAPID(cap-id)Lsm(lsm-id)
CAPID(00:00:00)
CEllRow(rr)
Row(00)Lsm(00:00)
Lsm(lsm-id) Panel(pp)
Panel(00)
Column(cc)
Column(00)
Column(cc)
Column(00)
DRive Address(xxx)Host(host-id)
PLaygrndLsm(00:00)
Lsm(lsm-id) Column(cc)
Column(00)
PTpLsm(00:00)
Lsm(lsm-id) Xlsm(ll) Column(c)
Column(0)
Time(ttt)
Row(rr)
Row(00)
60 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 73: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/73.jpg)
Warn command
Media Types Recording Techniques
LONGItud LONGItud, 18track, 36track, 36Atrack, 36Btrack, 36Ctrack
Standard
ECART
ZCART
DD3, DD3A, DD3B, DD3C HELical, DD3
STK1, STK1R STK1R, STK1R34, STK1R35, STK1RA, STK1RA34, STK1RA35, STK1RB, STK1RB34, STK1RB35, STK1RAB, STK1RAB4, STK1RAB5, STK1RC, STK1RC34, STK1RC35, STK1RD, STK1RDE, STK1RDN, STK1RD34, STK1RD35, STK1RDE4, STK1RDE5
STK2, STK2P STK2P, STK2P34, STK2P35, STK2PA, STK2PA34, STK2PA35, STK2PB, STK2PB34, STK2PB35
LTO-10G, LTO-35G, LTO-50G, LTO-100G, LTO-200G, LTO-400G, LTO-400W, LTO-800G, LTO-800W
*
* No corresponding recording technique.
SDLT, SDLT-2, SDLT-S1, SDLT-S2, SDLT-S3, SDLT-S4, SDLT-4
*
T10000T1, T10000TS T10K, T10KN, T10KE, T1A, T1AN, T1A34, T1A35, T1AE, T1AE34, T1AE35, T1B, T1BN, T1B34, T1B35, T1BE, T1BE34, T1BE35
Warn SCRatchlsm-idacs-id
SUBpool(subpool-name)THReshld(threshold-value)
MEDia( media-type ) RECtech( recording-technique,
)
HSC Operator Command Syntax 61Rev. E, 5/31/09 - 312597501
![Page 74: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/74.jpg)
62 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 75: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/75.jpg)
HSC Diagnostic Command Syntax
This section contains the syntax for diagnostic commands. For complete descriptions of the commands, see the HSC System Programmer’s Guide and HSC Operator’s Guide.
HSC Diagnostic Command Syntax 63
Rev. E, 5/31/09 - 312597501
![Page 76: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/76.jpg)
LIst command
TRace command
LIST
length
control-block
?
offset+
length?
16
cb length
-
offset+
-
address
length?
50
offset+
-
LVT-label
TRacecomp-name
comp-list,
OFF comp-name
comp-list,
64 HSC 6.1 (MVS) Reference SummaryRev. E, 5/31/09 - 312597501
![Page 77: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/77.jpg)
![Page 78: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/78.jpg)
Printed in U.S.A.
![Page 79: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/79.jpg)
![Page 80: StorageTek™ Host Software Component (HSC) · 2009-05-28 · About this Summary ix Rev. E, 5/31/09 - 312597501 About this Summary This summary contains frequently used syntax information](https://reader035.fdocuments.net/reader035/viewer/2022070917/5fb723bf59c5c578e0517f05/html5/thumbnails/80.jpg)
SUN™ THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo are trademarks or registered trademarks of Sun Microsystems, Inc. in theUnited States and other countries.
Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-650-960-1300 or 1-800-555-9SUN Web sun.com
ARGENTINA: 5411-4317-5636 • AUSTRALIA: 1-800-550-786 • AUSTRIA: 43-1-601-26-0 • BALKANS: 301-6188-111 • BELGIUM: 32 2-704 89 83 • BRAZIL: 55-11-51872100 • BRUNEI: 65-216-8333 • CANADA: 1-800-422-8020 (GENERAL); 416-964-2001 (LEARNING MANAGEMENT SYSTEM SALES,TORONTO) • CHILE: 562-372-4500 • COLOMBIA: 571-629-2323CZECH REPUBLIC: 420 2 33009311 • DENMARK: 45 4556 5040 • EGYPT: 00 202 570 9442 • FINLAND: 358-9-525-561 • FRANCE: 33-1-41-33-17-17 • GERMANY: 49-89-460-08-2788 • GREECE: 30-01-6188101 • HONG KONG: 852-2877-7077 • HUNGARY: 361-202-4415 • INDIA: 91-80-229-8989 • INDONESIA: 65-216-8333 • IRELAND: 353-1-668-4377ISRAEL: 972-9-9710500 • ITALY: 39-02-9259511 • JAPAN: 81-3-5779-1820 • KOREA: 82-2-3453-6602 • MALAYSIA: 603-2116-1887 • MIDDLE EAST: 00 9714 3366333 • MEXICO: 525-261-0344 • NETHERLANDS: 31-33-4515200 • NEW ZEALAND: 0800-786-338 • NORTH WEST AFRICA: 00 9714 3366333 • NORWAY: FROM NORWAY: 47-22023950, TO NORWAY:47-23369650 • PAKISTAN: 00-9714-3366333 • PEOPLE'S REPUBLIC OF CHINA: 8610-6803-5588 • PHILIPPINES: 632-885-7867 • POLAND: 48-22-8747848 • PORTUGAL: 351-21-413-4000 • RUSSIA: 7-095-935-8411 • SAUDI ARABIA: 00 9714 3366333 • SINGAPORE: 65-216-8300 • SOUTH AFRICA: 27-11-256-6300 • SPAIN: 34-902-210-412 • SRI LANKA:65-2168333 • SWEDEN: 46-8-631 22 00 • SWITZERLAND: 41-1-908-90-50 (GERMAN) 41-22-999-0444 (FRENCH) • TAIWAN: 886-2-25185735 • THAILAND: 662-344-6855 • TURKEY: 90 212 335 22 00 • UNITED KINGDOM: 44-1276-416-520 • UNITED STATES: 1-800-422-8020 • VENEZUELA: 582-905-3800 • VIETNAM: 65-216-8333 • WORLDWIDE
HEADQUARTERS: 1-650-960-1300