Storage/SAN Compatibility Guide

1405
Storage/SAN Compatibility Guide Copyright © 2010-2017 VMware, Inc. All rights reserved. page 1 of 1405 Storage/SAN Compatibility Guide Last Updated: January 30, 2018 For more information go to vmware.com. Introduction VMware ESX software has been tested and deployed in a variety of storage network environments. This guide describes the storage devices currently tested by VMware and its storage partners. ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility information. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions. Note: ESXi does not support Boot From SAN (Fiber Channel or iSCSI), for all products. If you are having a technical issue with 3rd party HW/SW and it is not found on this list, please refer to our 3rd Party HW/SW support policy at http://www.vmware.com/support/ policies/ThirdParty.html. VMware works closely with each of its OEMs to drive towards mutual support of ESX at the time of announcement. Due to different product release cycles, levels of testing, and OEM agreements, not all OEM devices will be supported at the general availability date of a new version of ESX. We recommend contacting the OEM vendor for the best information on when their device is planned to be certified with Virtual Infrastructure. For further details about array firmware, storage product configurations and best practices, please contact the storage vendor. NOTE: The use of an external enclosure, or JBOD connected to a supported SAS/SCSI controller in a supported server is supported, as long as there is no disk sharing among multiple servers or SAS/SCSI cards. There are several items on the ESX 2.5.x SAN Compatibility Guide (http://www.vmware.com/pdf/esx_SAN_guide.pdf ) that are not on this 3.x list. Please contact your storage vendors for plans regarding these items. Windows Clustering (MSCS) with ESX 3.0.x Windows Clustering refers Cluster Services in Windows 2003 and 2000 in a shared disk configuration between two virtual machines or a virtual machine and a physical system. Such clustering is certified only with a subset of arrays listed in this guide. Windows Clustering (MSCS) with ESX 3.5.x MSCS is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more information and configuration details. a subset of arrays listed in this guide. It is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more information and configuration details. Fibre Channel SANs For Fibre Channel SANs, if listed, VMware supports the following configuration, unless footnoted otherwise:

Transcript of Storage/SAN Compatibility Guide

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 1 of 1405

    Storage/SAN Compatibility GuideLast Updated: January 30, 2018For more information go to vmware.com.

    IntroductionVMware ESX software has been tested and deployed in a variety of storage network environments. This guide describes the storage devices currently tested by VMware and itsstorage partners.

    ESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibility information. Ifa product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions.

    Note: ESXi does not support Boot From SAN (Fiber Channel or iSCSI), for all products.

    If you are having a technical issue with 3rd party HW/SW and it is not found on this list, please refer to our 3rd Party HW/SW support policy at http://www.vmware.com/support/policies/ThirdParty.html.

    VMware works closely with each of its OEMs to drive towards mutual support of ESX at the time of announcement. Due to different product release cycles, levels of testing,and OEM agreements, not all OEM devices will be supported at the general availability date of a new version of ESX. We recommend contacting the OEM vendor for the bestinformation on when their device is planned to be certified with Virtual Infrastructure.

    For further details about array firmware, storage product configurations and best practices, please contact the storage vendor.

    NOTE: The use of an external enclosure, or JBOD connected to a supported SAS/SCSI controller in a supported server is supported, as long as there is no disk sharing amongmultiple servers or SAS/SCSI cards.

    There are several items on the ESX 2.5.x SAN Compatibility Guide (http://www.vmware.com/pdf/esx_SAN_guide.pdf

    ) that are not on this 3.x list. Please contact your storage vendors for plans regarding these items.

    Windows Clustering (MSCS) with ESX 3.0.xWindows Clustering refers Cluster Services in Windows 2003 and 2000 in a shared disk configuration between two virtual machines or a virtual machine and a physical system.Such clustering is certified only with a subset of arrays listed in this guide.

    Windows Clustering (MSCS) with ESX 3.5.xMSCS is supported with ESX 3.5 with both 32 bit and 64 bit VMs running Windows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMwareESX 3.5 software with your storage array, please examine the lists on the following pages to find out whether your array and configuration are supported. Please refer to yourstorage vendor for more information and configuration details. a subset of arrays listed in this guide. It is supported with ESX 3.5 with both 32 bit and 64 bit VMs runningWindows 2003. Only 4Gb HBAs are supported with MSCS and ESX 3.5. Before installing VMware ESX 3.5 software with your storage array, please examine the lists on thefollowing pages to find out whether your array and configuration are supported. Please refer to your storage vendor for more information and configuration details.

    Fibre Channel SANsFor Fibre Channel SANs, if listed, VMware supports the following configuration, unless footnoted otherwise:

    http://www.vmware.com

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 2 of 1405

    * Basic Connectivity - The ability of ESX 3.x hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing or any type of failover.

    * Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device.

    * HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting to one or more SAN switches. The server is robust to HBA and switch failureonly.

    * Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports and is robust to storage port failures.

    * Boot from SAN - In this configuration, the ESX 3.x host boots from a LUN stored on the SAN rather than a local disk.

    * Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Clustering is not supported in thisconfiguration.

    NOTE: Windows Clustering (MSCS) support applies to Windows 2000 SP4, Windows 2003 RTM, SP 1, R2 and SP 2. For ESX version requirements for these operating systemsin cluster environment, please refer to http://kb.vmware.com/kb/2021. Clustering is supported only with a limited set of HBAs; please refer to the I/O Compatibility Guide (http://www.vmware.com/pdf/vi3_io_guide.pdf) for the list of HBAs not supported with Windows Clustering.

    NOTE: MSCS is not supported, unless footnoted.

    NOTE: MSCS is not supported for Direct Connect.

    NOTE: Only footnoted storage arrays are supported with Brocade 415 and 425 HBAs.

    NOTE: Unless otherwise footnoted, all fibre channel arrays are supported with both 2Gb and 4Gb FC HBAs on ESX

    NOTE: For ESX 3.5 U2 onwards unless otherwise footnoted, all fibre channel arrays are supported with 2Gb, 4Gb and 8Gb FC HBAs on ESX.

    NOTE: For devices with external SAN storage support, please refer to Storage Virtualization Device (SVD).

    NOTE: Unless otherwise noted, all fibre channel storage products are supported in a boot from SAN configuration.

    Storage Virtualization Device (SVD)VMware supports Storage Virtualization Devices (SVD) with ESX 3.0.2 or later.

    * Backend storage arrays must be listed on both the ESX 3.x Storage/SAN Compatibility Guide and the SVD Vendor supported list.

    * Do not share the same LUN of the backend storage array between SVD and any other host.

    * Only devices that are listed with Array Type SVD are allowed to connect to external Fibre Channel SAN storages.

    * Only Fibre Channel protocol from SVD device to ESX is supported.

    Storage Arrays supported with FCoE CNAsFibre Channel Over Ethernet Converged (FCoE) Network Adapters (CNAs) can be concurrently connected to Fibre Channel Fabrics and Ethernet networks, through FCoE capableswitches. Certified Fibre Channel arrays will be listed soon. Only the Fibre Channel arrays that will be listed with this array type are certified to work and supported with FCoECNAs. CNAs are not yet supported to connect with iSCSI and NFS storage arrays.

    Network Attached StorageThe following Linux distributions support network attached storage when used with ESX 3.x software:

    * Red Hat Enterprise Linux 5 NFS Server (Update 2).

    * Red Hat Enterprise Linux 3 NFS Server (Update 5).

    * Fedora Core 4 NFS Server (2.6.12-1.1456_FC4.9550smp).

    * Fedora Core 6 NFS Server (2.6.18-1.2798.fc6 #1 SMP) for ESX 3.5 only.

    NOTE: Windows Clustering (MSCS) is not supported with NAS.

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 3 of 1405

    iSCSIVMware supports connections to iSCSI arrays using either the software initiator in the kernel or a hardware initiator (iSCSI HBA). Please refer to the I/O Compatibility Guide fora list of hardware initiators that can be used with ESX.

    The following maximums are in place when using iSCSI arrays with ESX hosts:

    * Number of HBAs - software (1); hardware (1 dual port or 2 single port)

    * Maximum number of targets - both software and hardware initiator (64)

    * Number of LUNs both software and hardware initiator (254)

    * Number of paths to storage - software (4); hardware (8)

    For iSCSI storage with the software initiator over a supported NIC, if listed, VMware supports the following configuration, unless footnoted otherwise:

    * iSCSI Base Connectivity - The ability of an ESX host to recognize the target and interoperate with it.

    * SP failover - In this configuration the ESX host is attached to multiple ports and is robust to storage port failover

    * NIC failover for software initiator - If the Ethernet adapters are teamed and one fails, the other one takes over. Both adapters must be connected to the same physical switch andbe on the same subnet (both NICs and iSCSI storage ports).

    For iSCSI storage with hardware initiators, if listed, VMware supports the following configuration, unless footnoted otherwise:

    * iSCSI Base Connectivity - The ability of an ESX host to recognize the target over an iSCSI HBA and interoperate with it.

    * SP failover - In this configuration, ESX host is attached to multiple ports over an iSCSI HBA and is robust to storage port failover.

    * Boot from iSCSI - In this configuration, ESX hosts boot from the target iSCSI array rather than from a local disk.

    * iSCSI hardware initiator failover - The ESX host is equipped with multiple hardware initiators and is robust to hardware initiator failover.

    NOTE: Windows Clustering is not supported with iSCSI.

    NOTE: Software initiated iSCSI is supported fully in ESX 3.0 and later releases. Hardware initiated iSCSI is supported in experimental mode only in ESX 3.0. It is supported fullyin ESX 3.0.1 with iSCSI arrays that have been qualified/certified for use with the hardware initiators.

    SAS ArraysFor SAS Arrays, if listed, VMware supports the following configuration, unless footnoted otherwise:

    * Basic Connectivity - The ability of ESX 3.5 hosts to recognize and interoperate with the storage array. This configuration does not allow for multipathing, any type of failover, orsharing of LUNs between multiple hosts.

    * Direct Connect - In this configuration, the ESX 3.x host is directly connected to the array (that is, no switch between HBA and the array). Windows Clustering is not supported inthis configuration.

    * LUN sharing - The ability of multiple ESX 3.x hosts to share the same LUN.

    * Multipathing - The ability of ESX 3.x hosts to handle multiple paths to the same storage device.

    * HBA Failover - In this configuration, the ESX 3.x host is equipped with multiple HBAs connecting directly to the array. The server is robust to HBA failure only.

    * Storage Port Failover - In this configuration, the ESX 3.x host is attached to multiple storage ports on the same array and is robust to storage port failures.

    Maximum Storage Specifications SupportedThe following system and virtual machine maximums are supported for ESX hosts:

    Maximum LUNs per system: 256 (128 during install)

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 4 of 1405

    Maximum HBAs per system: 16 ports (4 quad port cards, 8 dual port cards, etc.)

    Maximum virtual HBAs per virtual machine: 4

    Maximum targets per virtual HBA: 15

    Maximum virtual disks per Windows virtual machine: 60

    Maximum virtual disks per Linux virtual machine: 60

    Maximum number of VMFS file systems per server: 256

    Maximum disk space per VMFS: 2TB * # of extents

    Maximum file size per VMFS-3 file: Default max file size for VMFS 3 is 256GB (block size of 1MB). This can be configured to a block size of 8MB which will allow a2TB file.

    Maximum number of files per VMFS-3: Supports enough files to hold the maximum number of VMs per VMFS volume supported by ESX 3.0 (typically greater than30,000 files)

    Maximum number of paths per LUN: 32

    Maximum number of total paths: 1024

    Maximum number of targets per HBA: 15

    Minimum VMFS 3 volume size: 1.1 GB

    Third-Party SoftwareThird party backup, replication, and snapshot software is certified and supported by the providers of the software. The ESX 2.5 guide at http://www.vmware.com/pdf/esx25_san_cfg.pdf shows the list of software that was supported with ESX 2.5. Please contact your SAN vendors regarding their plans to support ESX 3.x. Asvendors certify software, we will create a list of certified software for ESX 3.x.

    http://www.vmware.com/pdf/esx25_san_cfg.pdfhttp://www.vmware.com/pdf/esx25_san_cfg.pdf

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 5 of 1405

    Storage Array Device and Model InformationESX, ESXi Embedded and ESXi Installable are equivalent products from a storage compatibility perspective. In this guide we only explicitly list ESX compatibilityinformation. If a product is listed as supported for ESX, the product is also supported for ESXi Embedded and ESXi Installable corresponding versions.

    The detailed lists show actual vendor devices that are either physically tested or are similar to the devices tested by VMware or VMware partners. VMwareprovides support only for the devices that are listed in this document

    Fibre Channel Array (FC)

    3PAR

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    E200 N/A Active/Active Fixed VV

    ESX 3.01,kb1, ESX 3.0.1kb1, ESX 3.0.2kb1,

    ESX 3.0.2 U1kb1, ESX 3.0.3kb1, ESX 3.0.3

    U1kb1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.12, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3

    2.2, 2.3, 2.3.1 MU2 orhigher, 2.30, InformOS 3.1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2300_707_vmwver. 7.08-vm60, qla2x00_707 ver.7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,qla2300_707_vmw ver. 7.08.66, qla2xxx ver.821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,qla2xxx ver. 821.k1.381vmw, fnic ver.1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,qla2xxx ver. 8.02.01-k1-vmw48, qla2xxxver. 831.k1.28.1-1vmw, fnic ver.1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,lpfc820 ver. 8.2.1.90.28, qla2xxx ver.821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.831.k1.28.1-7vmw

    FC Switch 3PARdata

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 6 of 1405

    F-Class N/A Active/Active Fixed VV

    ESX 3.01,kb1, ESX 3.0.1kb1, ESX 3.0.2kb1,

    ESX 3.0.2 U1kb1, ESX 3.0.3kb1, ESX 3.0.3

    U1kb1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.13, ESX 4.1 U1, ESX

    4.1 U2, ESX 4.1 U3, ESXi 5.04,kb2, ESXi 5.0

    U1kb2, ESXi 5.0 U2kb2, ESXi 5.0 U3kb2, ESXi

    5.1kb2, ESXi 5.1 U1kb2, ESXi 5.1 U2kb2, ESXi

    5.1 U3kb2, ESXi 5.55,kb2, ESXi 5.5 U16,kb2,

    ESXi 5.5 U2kb2, ESXi 5.5 U3kb2, ESXi 6.0kb2,

    ESXi 6.0 U1kb2, ESXi 6.0 U2, ESXi 6.0 U3

    2.2, 2.3, 2.3.1 MU2or higher, 2.30, 3.1,3.1.2, 3.1.3, Inform OS3.1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm60,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, lpfc_740ver. 7.4.0.40, qla2300_707_vmw ver.7.08.66, qla2xxx ver. 821.k1.38vmw,qla2xxx ver. 831.k1.23vmw, qla2xxx ver.821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,qla2xxx ver. 831.k1.28.1-1vmw, fnicver. 1.1.0.113.1-4vmw, lpfc820 ver.8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,lpfc820 ver. 8.2.0.90.28, lpfc820 ver.8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa ver.3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,lpfc820 ver. 8.2.2.105.36, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,lpfc820 ver. 8.2.1.126.50, lpfc820 ver.8.2.0.126.50, lpfc820 ver. 8.2.2.105.34,qla2xxx ver. 934.5.4.0-1vmw, qla2xxxver. 902.k1.1-9vmw, lpfc820 ver.8.2.3.1-127vmw, lpfc820 ver. 8.2.4.151.65,lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.575.8, bnx2fcver. 1.78.16.v55.4, bfa ver. 3.2.3.0, qlnativefcver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw,qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    FC Switch 3pardata

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 7 of 1405

    NAS NMP VMW_SATP_ALUA VMW_PSP_MRU N/A

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.5, ESX 3.5U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    6.xxx, 6110, XCS6200

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw

    FC Switch N/A

    S400 N/A Active/Active Fixed VV

    ESX 3.01,kb1, ESX 3.0.1kb1, ESX 3.0.2kb1,

    ESX 3.0.2 U1kb1, ESX 3.0.3kb1, ESX 3.0.3

    U1kb1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.12, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3

    2.2, 2.3, 2.3.1 MU2 orhigher, 2.30, InformOS 3.1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2300_707_vmwver. 7.08-vm60, qla2x00_707 ver.7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, lpfc_740 ver. 7.4.0.40,qla2300_707_vmw ver. 7.08.66, qla2xxx ver.821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,qla2xxx ver. 821.k1.381vmw, fnic ver.1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,qla2xxx ver. 8.02.01-k1-vmw48, qla2xxxver. 831.k1.28.1-1vmw, fnic ver.1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,lpfc820 ver. 8.2.1.90.28, qla2xxx ver.821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.831.k1.28.1-7vmw

    FC Switch 3PARdata

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 8 of 1405

    S800 N/A Active/Active Fixed VV

    ESX 3.01,kb1, ESX 3.0.1kb1, ESX 3.0.2kb1,

    ESX 3.0.2 U1kb1, ESX 3.0.3kb1, ESX 3.0.3

    U1kb1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.12, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3

    2.2, 2.3, 2.3.1, 2.3.1MU2 or higher, InformOS 3.1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm60,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, lpfc_740 ver.7.4.0.40, qla2300_707_vmw ver. 7.08.66,qla2xxx ver. 821.k1.38vmw, qla2xxx ver.831.k1.23vmw, qla2xxx ver. 821.k1.43vmw,qla2xxx ver. 821.k1.381vmw, fnic ver.1.1.0.108, fnic ver. 1.1.0.112.2vmw-3vmw,qla2xxx ver. 8.02.01-k1-vmw48, qla2xxxver. 831.k1.28.1-1vmw, fnic ver.1.1.0.113.1-4vmw, lpfc820 ver. 8.2.0.90.28,lpfc820 ver. 8.2.1.90.28, qla2xxx ver.821.k1.48vmw, lpfc820 ver. 8.2.2.1-16vmw,qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.831.k1.28.1-7vmw

    FC Switch 3PARdata

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 9 of 1405

    T-Class N/A Active/Active Fixed VV

    ESX 3.0kb1, ESX 3.0.11,kb1, ESX 3.0.2kb1,

    ESX 3.0.2 U1kb1, ESX 3.0.3kb1, ESX 3.0.3

    U1kb1, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.13, ESX 4.1 U1, ESX

    4.1 U2, ESX 4.1 U3, ESXi 5.04,kb2, ESXi 5.0

    U1kb2, ESXi 5.0 U2kb2, ESXi 5.0 U3kb2, ESXi

    5.1kb2, ESXi 5.1 U1kb2, ESXi 5.1 U2kb2, ESXi

    5.1 U3kb2, ESXi 5.55,kb2, ESXi 5.5 U16,kb2,

    ESXi 5.5 U2kb2, ESXi 5.5 U3kb2, ESXi 6.0kb2,

    ESXi 6.0 U1kb2, ESXi 6.0 U2, ESXi 6.0 U3

    2.2, 2.3, 2.3.1 MU2or higher, 2.30, 3.1,3.1.2, 3.1.3, Inform OS3.1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm60,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, lpfc_740ver. 7.4.0.40, qla2300_707_vmw ver.7.08.66, qla2xxx ver. 821.k1.38vmw,qla2xxx ver. 831.k1.23vmw, qla2xxx ver.821.k1.381vmw, fnic ver. 1.1.0.108, fnic ver.1.1.0.112.2vmw-3vmw, qla2xxx ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,qla2xxx ver. 831.k1.28.1-1vmw, fnicver. 1.1.0.113.1-4vmw, lpfc820 ver.8.2.0.79.28, qla2xxx ver. 841.k1.16.2-1vmw,lpfc820 ver. 8.2.0.90.28, lpfc820 ver.8.2.1.90.28, qla2xxx ver. 821.k1.48vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa ver.3.0.0.0, qla2xxx ver. 911.k1.1-9vmw,lpfc820 ver. 8.2.2.105.36, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,lpfc820 ver. 8.2.1.126.50, lpfc820 ver.8.2.0.126.50, lpfc820 ver. 8.2.2.105.34,qla2xxx ver. 934.5.4.0-1vmw, qla2xxxver. 902.k1.1-9vmw, lpfc820 ver.8.2.3.1-127vmw, lpfc820 ver. 8.2.4.151.65,lpfc ver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.575.8, bnx2fcver. 1.78.16.v55.4, bfa ver. 3.2.3.0, qlnativefcver. 1.1.12.0, lpfc820 ver. 8.2.3.1-129vmw,qla2xxx ver. 934.5.29.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    FC Switch 3PARdata

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 10 of 1405

    Aberdeen LLC

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    XDAS D22H7m NMP VMW_SATP_ALUA VMW_PSP_MRU DS_B24F-R2852-6

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U24, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3

    5.1x qla2xxx ver. 901.k1.1-14vmw FC Switch IFT

    XDAS GX22m NMP VMW_SATP_ALUA VMW_PSP_MRU DS_4000

    ESXi 5.54, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.5x qlnativefc ver. 1.0.12.0-1vmw, lpfcver. 10.0.100.1-1vmw, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,lpfc ver. 11.1.0.6-1vmw, qlnativefc ver.2.1.50.0-1vmw

    16G FC Switch IFT

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 11 of 1405

    AC&NC

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    JetStor SAS 516F NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 516F

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 516F N/A Active/Active MRU JetStor SAS 516F

    ESX 3.5 U28, ESX 3.5 U3, ESX 3.5 U4, ESX3.5 U5

    1.45 qla2300_707_vmw ver. 7.08-vm32 FC Switch ACNC

    JetStor SAS 516F 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 516F 8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 616F 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 616F 8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 616F V2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 616F V2

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 624F NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 624F NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 12 of 1405

    JetStor SAS 624F 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624F 8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 624FS NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 624FS NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 624FS 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 624FS8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 642F 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642F 8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 642F V2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642F V2

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 642FS 8G NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642FS8G

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 13 of 1405

    JetStor SAS 642FS V2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_MRU JetStor SAS 642FSV2

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3

    1.47 N/A FC Direct Attach AC&NC

    JetStor SAS 716F NMP VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 716F

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3

    1.49DC N/A FC Switch ACNC

    JetStor SAS 716FD NMP VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 716FD

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3

    1.49DC N/A FC Switch ACNC

    JetStor SAS 724FD NMP VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 724FD

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3

    1.49DC N/A FC Switch ACNC

    JetStor SAS 724iFD NMP VMW_SATP_ALUA VMW_PSP_RR JetStor SAS 724iFD

    ESXi 5.54, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    3.2.0 qlnativefc ver. 1.1.14.0 16G FC Switch ACNC

    JetStor SAS 742FD NMP VMW_SATP_ALUA VMW_PSP_MRU JetStor SAS 742FD

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3

    1.49DC N/A FC Switch ACNC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 14 of 1405

    AccelStor Inc

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    NeoSapphire 3605 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR NeoSapphire 3600

    ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    1.0.0 lpfc ver. 11.1.145.18, qlnativefc ver.2.1.50.0-1

    16G FC Switch AStor

    NeoSapphire 3611 NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR NeoSapphire 3600

    ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    1.0.0 lpfc ver. 11.1.145.18, qlnativefc ver.2.1.50.0-1

    16G FC Switch AStor

    NeoSapphire P310 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED NeoSapphire P310

    ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    2.1.0 lpfc ver. 10.2.309.8-2vmw, lpfc ver.11.1.0.6-1vmw

    16G FC Switch AStor

    NeoSapphire P710 NMP VMW_SATP_ALUA VMW_PSP_RR NeoSapphire P710

    ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    2.1.0 lpfc ver. 10.2.309.8-2vmw, lpfc ver.11.1.0.6-1vmw

    16G FC Switch AStor

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 15 of 1405

    Acer Inc.

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    Acer AMS2100 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U1, ESXi 5.0 U213, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 16 of 1405

    Acer AMS2300 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U1, ESXi 5.0 U213, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 17 of 1405

    Acer AS2040 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U113, ESXi 5.0 U2, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 18 of 1405

    Gateway AMS2100 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U1, ESXi 5.0 U213, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 19 of 1405

    Gateway AMS2300 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U1, ESXi 5.0 U213, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 20 of 1405

    Gateway GS2040 N/A Active/Active Fixed N/A

    ESX 3.0.2, ESX 3.0.2 U1, ESX 3.0.3, ESX

    3.0.3 U1, ESX 3.59, ESX 3.5 U1, ESX 3.5U2, ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5,

    ESX 4.010, ESX 4.0 U111, ESX 4.0 U2, ESX

    4.0 U3, ESX 4.0 U4, ESX 4.112, ESX 4.1 U1,

    ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04, ESXi

    5.0 U1, ESXi 5.0 U213, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.5, ESXi 5.5 U114, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    0832/E, 0846/B-M,0850/C-M, 0872/E-M, 0890/B or later,0893/B-M and above,08B0/A-M, 08B0/A-Mand above, 08B0/B-M, 08B3/A-M, 08C3/Eand above, 08C3/N orabove, 08XX/X

    lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla4xxx ver.5.01.00.vm1, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, bfa ver. 2.2.0.0,lpfc820 ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.0.79.25, qla4xxx ver. 5.01.00.vm1-3vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxx ver.901.k1.1-13vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, bfa.o ver.3.0.0.0, qla2xxx ver. 902.k1.1-9vmw,lpfc820 ver. 8.2.3.1-127vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfcver. 10.2.309.8-2vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 21 of 1405

    Areca

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    ARC-8667 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-8667

    ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,ESXi 5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi6.0 U2, ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.51 2013-08-14 qla2xxx ver. 902.k1.1-9vmw, qlnativefcver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    8G FC Switch ARECA

    ARC-8681 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-8681

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9212FD-DR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-8681

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9212FD-QR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9212FD-QR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9212FS-DR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9212FS-DR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9212FS-QR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9212FS-QR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9216FD-DR3 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9216FD-DR3

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 22 of 1405

    ARC-9216FD-QR3 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9216FD-QR3

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9216FS-DR3 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9216FS-DR3

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch Areca Technology,Inc.

    ARC-9216FS-QR3 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9216FS-QR3

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch Areca Technology,Inc.

    ARC-9224FD-DR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FD-DR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FD-DR4 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FD-DR4

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FD-QR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FD-QR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FD-QR4 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FD-QR4

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FS-DR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FS-DR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 23 of 1405

    ARC-9224FS-DR4 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FS-DR4

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FS-QR2 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FS-QR2

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

    ARC-9224FS-QR4 NMP VMW_SATP_ALUA VMW_PSP_MRU ARC-9224FS-QR4

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    V1.52-2015-11-20 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch ARECA

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 24 of 1405

    ASUSTeK Computer

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    DS300f G2 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED DS300f G2

    ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3

    1.01.0000.17 qla2xxx ver. 911.k1.1-26vmw 8G FC Switch ASUS

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 25 of 1405

    ATTO Technology, Inc

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    FCBR-7500-DPS NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED XstreamCORE FC7500

    ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    2.00 celerity16fc ver. 1.06 16G FC Switch ATTO

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 26 of 1405

    Bull S.A.S

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    Bull Optima1600 NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX

    4.0 U4, ESX 4.115, ESX 4.1 U1, ESX 4.1 U2,

    ESX 4.1 U3, ESXi 5.016, ESXi 5.0 U14, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,

    ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.517, ESXi5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    010A lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, lpfc820ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,lpfc ver. 10.0.100.1-1vmw, lpfc ver.10.2.309.8-2vmw, lpfc ver. 11.1.0.6-1vmw

    8G FC Switch NEC

    Bull Optima2000 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage 1000

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX

    4.0 U4, ESX 4.115, ESX 4.1 U1, ESX 4.1 U2,ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    010A lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, lpfc820 ver.8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw

    8G FC Switch NEC

    Bull Optima2600 NMP VMW_SATP_ALUA VMW_PSP_MRU DISK ARRAY

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX

    4.0 U4, ESX 4.115, ESX 4.1 U1, ESX 4.1 U2,

    ESX 4.1 U3, ESXi 5.016, ESXi 5.0 U14, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,

    ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.517, ESXi5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    010A lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, lpfc820ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,lpfc ver. 10.0.100.1-1vmw, lpfc ver.10.2.309.8-2vmw, lpfc ver. 11.1.0.6-1vmw

    8G FC Switch NEC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 27 of 1405

    Bull Optima3600 NMP NEC_SATP_SPS v500.1.0-010001.0247 VMW_PSP_MRU DISK ARRAY

    ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX

    4.0 U4, ESX 4.115, ESX 4.1 U1, ESX 4.1 U2,

    ESX 4.1 U3, ESXi 5.04, ESXi 5.0 U1, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    010A lpfc820 ver. 8.2.0.30.52vmw, lpfc820ver. 8.2.0.30.52vmw-4, lpfc820ver. 8.2.1.30.1-58vmw, lpfc820 ver.8.2.2.1-18vmw, lpfc ver. 10.0.100.0-1vmw,lpfc ver. 10.0.100.1-1vmw, lpfc ver.10.2.309.8-2vmw, lpfc ver. 11.1.0.6-1vmw

    8G FC Direct Attach NEC

    Optima 1200 N/A Active/Passive MRU F5402E

    ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX3.0.3, ESX 3.0.3 U1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch iStorage

    Optima 5000 N/A Active/Active Fixed 1000

    ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX3.0.3, ESX 3.0.3 U1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch iStorage

    Optima1500 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage

    ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3

    010A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw

    FC Switch NEC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 28 of 1405

    StoreWay FDA1500 N/A Active/Active Fixed 1000

    ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    010A, FW436 qla2x00_707 ver. 7.07.00, lpfcdd_732 ver.7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01,lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw

    FC Switch iStorage

    StoreWay FDA2500 N/A Active/Active Fixed 2000

    ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    010A, F/W436 qla2x00_707 ver. 7.07.00, lpfcdd_732 ver.7.3.2_vmw2, qla2x00_707 ver. 7.07.04.01,lpfcdd_732 ver. 7.3.2_vmw4, lpfc_740ver. elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfcdd_732 ver. 7.3.2_vmw10,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw

    FC Switch iStorage

    StoreWay FDA2800 N/A Active/Active Fixed 2000

    ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.1,ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    010A, FW435 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch iStorage

    StoreWay FDA2900 N/A Active/Active Fixed 2000

    ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2

    U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.518,ESX 3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1,ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    010A, FW435 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw

    FC Switch iStorage

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 29 of 1405

    StoreWay Optima1500 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage

    ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi5.1 U2, ESXi 5.1 U3

    010A lpfc820 ver. 8.2.2.1-18vmw FC Switch NEC

    StoreWay Optima3000 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED iStorage

    ESX 3.0.1, ESX 3.0.2, ESX 3.0.2 U1, ESX3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX 3.5 U1,ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,ESX 4.0 U3, ESX 4.0 U4, ESX 4.1, ESX 4.1

    U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.015,ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3

    010A lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw

    FC Switch NEC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 30 of 1405

    Cisco Systems, Inc.

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    UCS Invicta C3124A Appliance NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR Appliance

    ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,ESXi 5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi6.0 U2, ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.0.1.2 fnic ver. 1.6.0.12 HW FCoE Switch Cisco

    UCS Invicta Scaling System NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR INVICTA

    ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,ESXi 5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi6.0 U2, ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.0.1.3 fnic ver. 1.6.0.12b HW FCoE Switch CISCO

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 31 of 1405

    Compellent Technologies

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    Storage Center N/A Active/Active Fixed Vol

    ESX 3.0, ESX 3.0.1, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5U4, ESX 3.5 U5, ESX 4.0, ESX 4.0 U1, ESX

    4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX 4.115,ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi

    5.04, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi

    5.1 U3, ESXi 5.55,kb3, ESXi 5.5 U1kb3, ESXi

    5.5 U2kb3, ESXi 5.5 U3kb3, ESXi 6.0kb3, ESXi

    6.0 U1kb3, ESXi 6.0 U2, ESXi 6.0 U3, ESXi

    6.519, ESXi 6.5 U1

    3.5.1, 4.02, 5.0.1, 5.4,5.5.3, 5.5.x, 5.6, 6.0,6.0.x, 6.0x, 6.1.x, 6.2,6.3, 6.4, 6.5, 6.6, 6.7,7.0, 7.1, 7.2

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, qla2xxxver. 841.k1.16.2-1vmw, lpfc820ver. 8.2.2.1-18vmw, qla2xxx ver.901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,qla2xxx ver. 831.k1.28.1-7vmw, lpfc820ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55,qla2xxx ver. 934.5.6.0-1vmw, qla2xxxver. 841.k1.50.1-1vmw, lpfc820 ver.8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,qla2xxx ver. 934.5.22.0-1vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,lpfc ver. 10.0.575.8, lpfc ver. 10.0.727.44,qlnativefc ver. 1.1.20.0-1, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,lpfc ver. 10.2.455.0, qlnativefc ver.1.1.41.0-1, lpfc ver. 10.6.126.0, qlnativefcver. 1.1.55.0-1, qlnativefc ver. 1.1.70.0-1, lpfcver. 11.1.145.18, lpfc ver. 11.1.0.6-1vmw,qlnativefc ver. 2.1.50.0-1vmw

    FC Switch Compellent

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 32 of 1405

    Cybernetics

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    iSAN 1000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU iSAN 1000 Series

    ESXi 5.520, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.87 qlnativefc ver. 1.1.41.0-1 16G FC Switch Cybernet

    iSAN 2000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU iSAN 2000 Series

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.90 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    8G FC Switch Cybernet

    iSAN 3000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU iSAN 3000 Series

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    5.90 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    8G FC Switch Cybernet

    iSAN 5000 Series NMP VMW_SATP_ALUA VMW_PSP_MRU N/A

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    6.07 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 33 of 1405

    Data Fault Tolerance System CO., LTD

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    ES3390-D NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU ES3390-D

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    110-000066-111221630016-r10.6

    qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    8G FC Direct Attach DFT

    ES3391-D NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU ES3391-D

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    110-000066-111221630016-r10.6

    qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Direct Attach DFT

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 34 of 1405

    DataCore Software Corporation

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    SANsymphony NMP VMW_SATP_ALUA VMW_PSP_RR Virtual Disk

    ESX 4.021, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi 5.0 U1,ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi

    5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.54,ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3,

    ESXi 6.519, ESXi 6.5 U1

    10.0, 8.0, 9.0,v8.1.1.2, v9.0

    lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, lpfc820 ver. 8.2.2.1-18vmw,qla2xxx ver. 901.k1.1-14vmw, qlnativefc ver.1.0.12.0-1vmw, lpfc ver. 10.0.100.1-1vmw,qlnativefc ver. 2.0.12.0-5vmw, lpfc ver.10.2.309.8-2vmw, lpfc ver. 11.1.0.6-1vmw,qlnativefc ver. 2.1.50.0-1vmw

    FC Switch DataCore

    SMY-VS5-2970 N/A Active/Passive MRU SANmelody

    ESX 3.522, ESX 3.5 U123, ESX 3.5 U2, ESX3.5 U3, ESX 3.5 U4, ESX 3.5 U5

    2.0.3 qla2300_707_vmw ver. 7.08-vm33 FC Switch DataCore

    SSY-EWB-600-FPU with SANsymphony7.0

    NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANsymphony

    ESX 4.022, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3

    7.0 lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw

    FC Switch DataCore

    SSY-UNL-P-385 N/A Active/Passive MRU SANsymphony

    ESX 3.524, ESX 3.5 U123, ESX 3.5 U2, ESX3.5 U3, ESX 3.5 U4, ESX 3.5 U5

    6.0.2.2 qla2300_707_vmw ver. 7.08-vm32 FC Switch DataCore

    VS5-EWR-200-BSV with SANmelody 3.0 NMP VMW_SATP_DEFAULT_AP VMW_PSP_MRU SANmelody

    ESX 4.024, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0U3, ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX4.1 U2, ESX 4.1 U3

    3.0 lpfc820 ver. 8.2.0.30.46vmw, qla2xxx ver.821.k1.38vmw

    FC Switch Datacore

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 35 of 1405

    DataDirect Networks

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    S2A 9900 NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED S2A 9900

    ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4, ESX4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3

    6.10 qla2xxx ver. 8.02.01-k1-vmw48,qla2xxx ver. 831.k1.28.1-1vmw, qla2xxxver. 821.k1.48vmw, qla2xxx ver.831.k1.28.1-7vmw

    FC Switch DDN

    S2A6620 NMP VMW_SATP_ALUA VMW_PSP_MRU S2A 6620

    ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi5.1 U2, ESXi 5.1 U3

    1.4.0, 1.5 qla2xxx ver. 831.k1.28.1-1vmw, qla2xxxver. 901.k1.1-14vmw, qla2xxx ver.831.k1.28.1-7vmw

    FC Switch DDN

    SFA10000 NMP VMW_SATP_ALUA VMW_PSP_MRU SFA10000

    ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0, ESXi6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi 6.5,ESXi 6.5 U1

    1.4.0, 1.5, 3.0.0.0 qla2xxx ver. 901.k1.1-14vmw, qlnativefcver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    FC Switch DDN

    SFA12K NMP VMW_SATP_ALUA VMW_PSP_MRU SFA12K-20

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    2.2, 3.0.1, 3.1.0 qlnativefc ver. 1.1.14.0, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    16G FC Switch DDN

    SFA14K NMP VMW_SATP_ALUA VMW_PSP_MRU SFA14K

    ESXi 6.5, ESXi 6.5 U1 3.1.2 qlnativefc ver. 2.1.30.0-1 16G FC Switch DDN

    SFA7700 NMP VMW_SATP_ALUA VMW_PSP_MRU SFA7700

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    2.2, 3.1.2 qlnativefc ver. 1.1.14.0, qlnativefc ver.2.1.30.0-1

    16G FC Switch DDN

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 36 of 1405

    DELL

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    AX100 N/A Active/Passive MRU DGC

    ESX 3.0, ESX 3.0.118, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, aacraid_esx ver. 1.1-5[2415], lpfcdd_732 ver. 7.3.2_vmw4,qla2x00_707 ver. 7.07.04.2vmw,qla2x00_707 ver. 7.07.04.01.3vmw

    FC Switch EMC

    AX150 N/A Active/Passive MRU DGC

    ESX 3.0, ESX 3.0.118, ESX 3.0.2, ESX 3.0.2U1, ESX 3.0.3, ESX 3.0.3 U1, ESX 3.5, ESX3.5 U1, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5U4, ESX 3.5 U5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

    AX4-5 N/A Active/Passive MRU DEL

    ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5

    U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.025,kb4,

    ESX 4.0 U1kb4, ESX 4.0 U2kb4, ESX 4.0

    U3kb4, ESX 4.0 U4kb4, ESX 4.1kb4, ESX 4.1

    U1kb4, ESX 4.1 U2kb4, ESX 4.1 U3kb4, ESXi5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,ESXi 5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi6.0 U2, ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    Flare 23 lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    FC Switch DPG

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 37 of 1405

    Compellent Storage Center NMP VMW_SATP_DEFAULT_AA VMW_PSP_FIXED Compellent Vol

    ESX 3.0, ESX 3.0.1, ESX 3.5, ESX 3.5 U1,ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4, ESX3.5 U5, ESX 4.0, ESX 4.0 U1, ESX 4.0 U2,

    ESX 4.0 U3, ESX 4.0 U4, ESX 4.115, ESX

    4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi 5.04,ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3,

    ESXi 5.55,kb3, ESXi 5.5 U1kb3, ESXi 5.5 U2kb3,

    ESXi 5.5 U3kb3, ESXi 6.0kb3, ESXi 6.0 U1kb3,

    ESXi 6.0 U2, ESXi 6.0 U3, ESXi 6.519, ESXi6.5 U1

    3.5.1, 4.02, 5.0.1, 5.4,5.5, 5.5.3, 5.5.x, 5.6,6.0, 6.0.x, 6.0x, 6.1.x,6.2, 6.3, 6.4, 6.5, 6.6,6.7, 7.0, 7.1, 7.2

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfc_740 ver.elx_7.4.0.13, qla2300_707_vmw ver.7.08-vm32, lpfc820 ver. 8.2.0.30.49vmw,qla2xxx ver. 821.k1.38vmw, lpfc820ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, qla2xxxver. 841.k1.16.2-1vmw, lpfc820ver. 8.2.2.1-18vmw, qla2xxx ver.901.k1.1-14vmw, lpfc820 ver. 8.2.2.105.36,qla2xxx ver. 831.k1.28.1-7vmw, lpfc820ver. 8.2.4.141.55, lpfc820 ver. 8.2.1.141.55,qla2xxx ver. 934.5.6.0-1vmw, qla2xxxver. 841.k1.50.1-1vmw, lpfc820 ver.8.2.1.151.65, lpfc820 ver. 8.2.4.151.65,qla2xxx ver. 934.5.22.0-1vmw, lpfcver. 10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, qlnativefc ver. 1.1.7.0-1,lpfc ver. 10.0.575.8, lpfc ver. 10.0.727.44,qlnativefc ver. 1.1.20.0-1, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,lpfc ver. 10.2.455.0, qlnativefc ver.1.1.41.0-1, lpfc ver. 10.6.126.0, qlnativefcver. 1.1.55.0-1, qlnativefc ver. 1.1.70.0-1, lpfcver. 11.1.145.18, lpfc ver. 11.1.0.6-1vmw,qlnativefc ver. 2.1.50.0-1vmw

    FC Switch COMPELNT

    DELL/EMC Celerra NX4 N/A Active/Passive MRU N/A

    ESX 3.5, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5

    U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.025,kb4,

    ESX 4.0 U1kb4, ESX 4.0 U2kb4, ESX 4.0

    U3kb4, ESX 4.0 U4kb4, ESX 4.1kb4, ESX 4.1

    U1kb4, ESX 4.1 U2kb4, ESX 4.1 U3kb4, ESXi5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3,ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2, ESXi5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2,ESXi 5.5 U3

    Flare 23 lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, qla2xxx ver. 831.k1.23vmw,lpfc820 ver. 8.2.2.1-18vmw, qla2xxx ver.901.k1.1-14vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw

    FC Switch N/A

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 38 of 1405

    Dell/EMC CLARiiON CX200 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-10c N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX

    4.027, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.128, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-20 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 22, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-20c N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX

    4.027, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.128, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 39 of 1405

    Dell/EMC CLARiiON CX3-20f N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-40 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 22, Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-40c N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX

    4.027, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,

    ESX 4.0 U4, ESX 4.128, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX3-40f N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0 U3,ESX 4.0 U4, ESX 4.1, ESX 4.1 U1, ESX 4.1U2, ESX 4.1 U3

    Flare 26 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw

    FC Switch EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 40 of 1405

    Dell/EMC CLARiiON CX3-80 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5, ESX

    4.027,kb6, ESX 4.0 U1kb6, ESX 4.0 U2kb6, ESX

    4.0 U3kb6, ESX 4.0 U4kb6, ESX 4.128,kb6, ESX

    4.1 U1kb6, ESX 4.1 U2kb6, ESX 4.1 U3kb6

    Flare 26, Flare 7.8.60 lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707ver. 7.07.04.01.3vmw, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,bfa ver. 1.1.1.1, qla2xxx ver. 831.k1.23vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX300 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 41 of 1405

    Dell/EMC CLARiiON CX4-120 N/A Active/Passive MRU DGC

    ESX 3.0.1, ESX 3.0.2, ESX 3.529, ESX 3.5

    U130, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,

    ESX 3.5 U5, ESX 4.027,kb6, ESX 4.0 U1kb6,

    ESX 4.0 U2kb6, ESX 4.0 U3, ESX 4.0 U4,

    ESX 4.131, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1

    U3, ESXi 5.032, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi

    5.1 U2, ESXi 5.1 U3, ESXi 5.55, ESXi 5.5

    U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    04.28.000.3.203,04.28.000.3.208,04.28.000.5.003,04.30.000.5.506,Flare 28, Flare 28(04.28.000.5.704),Flare 29, Flare 30,Flare+30

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm33,lpfc820 ver. 8.2.0.30.49vmw, qla2xxxver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfaver. 2.1, qla2xxx ver. 831.k1.23vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.2.3.0.0, qla2xxx ver. 821.k1.48vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxxver. 901.k1.1-13vmw, qla2xxxver. 901.k1.1-14vmw, qla2xxxver. 831.k1.28.1-7vmw, lpfc ver.10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    N/A EMC

    Dell/EMC CLARiiON CX4-240 N/A N/A DGC

    ESX 3.530, ESX 3.5 U1, ESX 3.5 U2, ESX 3.5U3, ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX4.0 U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0U4, ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi5.1 U2, ESXi 5.1 U3

    04.28.000.3.203,04.28.000.3.208, Flare28, Flare 30

    lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfc820 ver. 8.2.0.30.49vmw, qla2xxx ver.821.k1.38vmw, lpfc820 ver. 8.2.2.1-16vmw,qla2xxx ver. 901.k1.1-13vmw, qla2xxx ver.901.k1.1-14vmw

    FC Switch EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 42 of 1405

    Dell/EMC CLARiiON CX4-480 N/A Active/Passive MRU DGC

    ESX 3.0.1, ESX 3.0.2, ESX 3.529, ESX 3.5

    U130, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,

    ESX 3.5 U5, ESX 4.027,kb6, ESX 4.0 U1kb6,

    ESX 4.0 U2kb6, ESX 4.0 U3, ESX 4.0 U4,

    ESX 4.131, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1

    U3, ESXi 5.032, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi

    5.1 U2, ESXi 5.1 U3, ESXi 5.55, ESXi 5.5

    U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    04.28.000.3.203,04.28.000.3.208,04.28.000.5.003,04.30.000.5.506,Flare 28, Flare 28(04.28.000.5.704),Flare 29, Flare 30,Flare+30

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm33,lpfc820 ver. 8.2.0.30.49vmw, qla2xxxver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfaver. 2.1, qla2xxx ver. 831.k1.23vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.2.3.0.0, qla2xxx ver. 821.k1.48vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxxver. 901.k1.1-13vmw, qla2xxxver. 901.k1.1-14vmw, qla2xxxver. 831.k1.28.1-7vmw, lpfc ver.10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    N/A EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 43 of 1405

    Dell/EMC CLARiiON CX4-960 N/A Active/Passive MRU DGC

    ESX 3.0.1, ESX 3.0.2, ESX 3.529, ESX 3.5

    U130, ESX 3.5 U2, ESX 3.5 U3, ESX 3.5 U4,

    ESX 3.5 U5, ESX 4.027,kb6, ESX 4.0 U1kb6,

    ESX 4.0 U2kb6, ESX 4.0 U3, ESX 4.0 U4,

    ESX 4.131, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1

    U3, ESXi 5.032, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi

    5.1 U2, ESXi 5.1 U3, ESXi 5.55, ESXi 5.5

    U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    04.28.000.3.203,04.28.000.3.208,04.28.000.5.003,04.30.000.5.506,Flare 28, Flare 28(04.28.000.5.704),Flare 29, Flare 30,Flare+30

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,qla2x00_707 ver. 7.07.04.2vmw,qla2300_707_vmw ver. 7.08-vm33,lpfc820 ver. 8.2.0.30.49vmw, qla2xxxver. 821.k1.38vmw, bfa ver. 1.1.1.1, bfaver. 2.1, qla2xxx ver. 831.k1.23vmw,lpfc820 ver. 8.2.0.30.52vmw, lpfc820 ver.8.2.0.30.52vmw-4, qla2xxx ver. 8.02.01-k1-vmw48, lpfc820 ver. 8.2.1.30.1-58vmw,qla2xxx ver. 831.k1.28.1-1vmw, bfa ver.2.3.0.0, qla2xxx ver. 821.k1.48vmw,lpfc820 ver. 8.2.2.1-16vmw, qla2xxxver. 901.k1.1-13vmw, qla2xxxver. 901.k1.1-14vmw, qla2xxxver. 831.k1.28.1-7vmw, lpfc ver.10.0.100.0-1vmw, qlnativefc ver.1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    N/A EMC

    Dell/EMC CLARiiON CX400 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX500 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 44 of 1405

    Dell/EMC CLARiiON CX600 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver. 7.3.2_vmw4,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

    Dell/EMC CLARiiON CX700 N/A Active/Passive MRU DGC

    ESX 3.0kb1, ESX 3.0.17,kb1, ESX 3.0.226,kb5,

    ESX 3.0.2 U1kb5, ESX 3.0.3kb5, ESX 3.0.3

    U1kb5, ESX 3.5, ESX 3.5 U1, ESX 3.5 U2,ESX 3.5 U3, ESX 3.5 U4, ESX 3.5 U5

    lpfcdd_732 ver. 7.3.2_vmw2, qla2x00_707ver. 7.07.04.01, lpfcdd_732 ver.7.3.2_vmw4, lpfc_740 ver. elx_7.4.0.13,qla2300_707_vmw ver. 7.08-vm32,lpfcdd_732 ver. 7.3.2_vmw10, qla2x00_707ver. 7.07.04.2vmw, qla2x00_707 ver.7.07.04.01.3vmw

    FC Switch EMC

    MD3600f NMP VMW_SATP_ALUA VMW_PSP_MRU MD36xxf

    ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi

    5.5 U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    07.80, 07.84, 08.10,08.20, Refer to vendorInteroperability Matrix,Refer to vendor'sInteroperability Matrix,Refer to vendorsInteroperability Matrix

    bnx2 ver. 1.3.22, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw, bfa ver.3.2.3.0, qlnativefc ver. 1.1.14.0, qlnativefcver. 2.0.12.0-5vmw, qlnativefc ver.2.1.50.0-1vmw

    8G FC Switch DELL

    MD3620f NMP VMW_SATP_LSI VMW_PSP_MRU MD36xxf

    ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi

    5.5 U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    07.80, 07.84, 08.10,08.20, Refer to vendorInteroperability Matrix,Refer to vendor'sInteroperability Matrix,Refer to vendorsInteroperability Matrix

    bnx2 ver. 1.3.22, lpfc820 ver.8.2.0.30.49vmw, qla2xxx ver. 821.k1.38vmw,lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw, bfa ver.3.2.3.0, qlnativefc ver. 1.1.14.0, qlnativefcver. 2.0.12.0-5vmw, qlnativefc ver.2.1.50.0-1vmw

    FC Switch DELL

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 45 of 1405

    MD3660f NMP VMW_SATP_ALUA VMW_PSP_MRU MD36xxf

    ESX 4.1 U1, ESX 4.1 U2, ESX 4.1 U3, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi

    5.5 U16, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    07.84, 08.10, 08.20 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.934.5.4.0-1vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw, bfa ver.3.2.3.0, qlnativefc ver. 1.1.14.0, qlnativefcver. 2.0.12.0-5vmw, qlnativefc ver.2.1.50.0-1vmw

    8G FC Switch DELL

    MD3800f NMP VMW_SATP_ALUA VMW_PSP_RR MD38xxf

    ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi

    5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.54,ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3,

    ESXi 6.519, ESXi 6.5 U1

    08.10, 08.20, 08.25,08.30, 08.40

    qla2xxx ver. 934.5.4.0-1vmw, qla2xxxver. 934.5.20.0-1vmw, lpfc820 ver.8.2.4.146.62, bfa ver. 3.2.1.0, qlnativefc ver.1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefcver. 1.1.14.0, lpfc ver. 10.0.662.204, lpfcver. 10.0.100.1-1vmw, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,qlnativefc ver. 2.1.30.0-1, qlnativefc ver.1.1.73.0-1, lpfc ver. 11.1.0.6-1vmw, qlnativefcver. 2.1.50.0-1vmw

    16G FC Switch DELL

    MD3820f NMP VMW_SATP_ALUA VMW_PSP_RR MD38xxf

    ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi

    5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.54,ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3,

    ESXi 6.519, ESXi 6.5 U1

    08.10, 08.20, 08.25,08.30, 08.40

    qla2xxx ver. 934.5.4.0-1vmw, qla2xxxver. 934.5.20.0-1vmw, lpfc820 ver.8.2.4.146.62, bfa ver. 3.2.1.0, qlnativefc ver.1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefcver. 1.1.14.0, lpfc ver. 10.0.662.204, lpfcver. 10.0.100.1-1vmw, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,qlnativefc ver. 2.1.30.0-1, qlnativefc ver.1.1.73.0-1, lpfc ver. 11.1.0.6-1vmw, qlnativefcver. 2.1.50.0-1vmw

    16G FC Switch DELL

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 46 of 1405

    MD3860f NMP VMW_SATP_ALUA VMW_PSP_RR MD3860f

    ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi

    5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.54,ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3,

    ESXi 6.519, ESXi 6.5 U1

    08.10, 08.20, 08.25,08.30, 08.40

    qla2xxx ver. 934.5.4.0-1vmw, qla2xxxver. 934.5.20.0-1vmw, lpfc820 ver.8.2.4.146.62, bfa ver. 3.2.1.0, qlnativefc ver.1.0.12.0-1vmw, bfa ver. 3.2.3.0, qlnativefcver. 1.1.14.0, lpfc ver. 10.0.662.204, lpfcver. 10.0.100.1-1vmw, qlnativefc ver.2.0.12.0-5vmw, lpfc ver. 10.2.309.8-2vmw,qlnativefc ver. 2.1.30.0-1, qlnativefc ver.1.1.73.0-1, lpfc ver. 11.1.0.6-1vmw, qlnativefcver. 2.1.50.0-1vmw

    16G FC Switch DELL

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 47 of 1405

    DEPO Electronics

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    DEPO Storage 4612/4624/4660 NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00

    ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2, ESXi5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi 5.1 U2,ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1, ESXi5.5 U2, ESXi 5.5 U3, ESXi 6.0, ESXi 6.0 U1,ESXi 6.0 U2, ESXi 6.0 U3, ESXi 6.5, ESXi6.5 U1

    07.80, 07.84, 07.86 lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver.831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.10.0.100.0-1vmw

    8G FC Switch LSI

    DEPO Storage 4812/4824/4860 NMP VMW_SATP_LSI VMW_PSP_MRU INF-01-00

    ESX 3.5 U511, ESXi 5.0, ESXi 5.0 U1, ESXi5.0 U2, ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1,ESXi 5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0,ESXi 6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi6.5, ESXi 6.5 U1

    07.80, 07.84, 07.86,Refer to vendorsInteroperability MatrixEquivalent

    qla2x00_707 ver. 7.07.04.01, bfa ver.1.0.0.02, lpfc_740 ver. elx_7.4.0.40.3,lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxx ver.831.k1.28.1-1vmw, bfa ver. 3.2.1.0, lpfc ver.10.0.100.0-1vmw

    8G FC Switch LSI

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 48 of 1405

    DEPO Storage 5312/5324 NMP VMW_SATP_ALUA VMW_PSP_MRU DH3000

    ESX 4.0, ESX 4.0 U1, ESX 4.0 U2, ESX 4.0

    U3, ESX 4.0 U4, ESX 4.133, ESX 4.1 U1,ESX 4.1 U2, ESX 4.1 U3, ESXi 5.0, ESXi5.0 U1, ESXi 5.0 U2, ESXi 5.0 U3, ESXi 5.1,ESXi 5.1 U1, ESXi 5.1 U2, ESXi 5.1 U3, ESXi5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi 5.5 U3,ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2, ESXi6.0 U3, ESXi 6.5, ESXi 6.5 U1

    T230, TS200R021,TS230, TS240,TS250, TS251, TS252

    qla2xxx ver. unknown, lpfc820ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, cciss ver.3.6.14.10.1-2vmw, e1000e ver. 0.4.1.7.1,e1000e ver. 1.1.2.1-1vmw, lpfc820ver. 8.2.2.1-18vmw, qla4xxx ver.5.01.03.2-3vmw, bfa ver. 3.0.0.0, lpfc820ver. 8.2.0.105.34, lpfc820 ver. 8.2.1.105.34,qla2xxx ver. 841.k1.28.1-1vmw, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.911.k1.1-19vmw, lpfc820 ver. 8.2.2.126.50,qla2xxx ver. 934.5.4.0-1vmw, lpfc820 ver.8.2.3.1-127vmw, lpfc ver. 10.0.100.0-1vmw,qlnativefc ver. 1.0.12.0-1vmw, qlnativefcver. 1.1.7.0-1, lpfc ver. 10.0.575.8, bnx2fcver. 1.78.16.v55.4, bfa ver. 3.2.3.0, lpfc820ver. 8.2.3.1-129vmw, lpfc ver. 10.0.662.204,qlnativefc ver. 2.0.12.0-5vmw, qlnativefc ver.2.1.50.0-1vmw

    SW iSCSI DotHill

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 49 of 1405

    Digital Networks UK Ltd

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    Zetavault NMP VMW_SATP_DEFAULT_AA VMW_PSP_RR ZVAULT

    ESXi 5.5, ESXi 5.5 U1, ESXi 5.5 U2, ESXi5.5 U3, ESXi 6.0, ESXi 6.0 U1, ESXi 6.0 U2,ESXi 6.0 U3, ESXi 6.5, ESXi 6.5 U1

    3.0 qlnativefc ver. 1.0.12.0-1vmw, qlnativefc ver.2.0.12.0-5vmw, qlnativefc ver. 2.1.50.0-1vmw

    FC Switch ZVAULT

  • Storage/SAN Compatibility Guide

    Copyright 2010-2017 VMware, Inc. All rights reserved.page 50 of 1405

    Dot Hill

    Model MPP SATP PSP Product Id

    Firmware Device Drivers Configuration Vendor Id

    3720 NMP Vendor_Unique Vendor_Unique D3720

    ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,ESX 4.1, ESX 4.1 U1, ESX 4.1 U2, ESX 4.1U3

    TS100R023 N/A FC Direct Attach DotHill

    3730/3720 NMP Vendor_Unique Vendor_Unique DH3000

    ESX 3.5 U4, ESX 3.5 U5, ESX 4.0, ESX 4.0U1, ESX 4.0 U2, ESX 4.0 U3, ESX 4.0 U4,

    ESX 4.133, ESX 4.1 U1, ESX 4.1 U2, ESX4.1 U3, ESXi 5.0, ESXi 5.0 U1, ESXi 5.0 U2,ESXi 5.0 U3, ESXi 5.1, ESXi 5.1 U1, ESXi5.1 U2, ESXi 5.1 U3, ESXi 5.5, ESXi 5.5 U1,ESXi 5.5 U2, ESXi 5.5 U3, ESXi 6.0, ESXi6.0 U1, ESXi 6.0 U2, ESXi 6.0 U3, ESXi 6.5,ESXi 6.5 U1

    T230, TS100R023,TS200R021, TS230,TS240, TS250,TS251, TS252

    lpfc820 ver. 8.2.1.30.1-58vmw, qla2xxxver. 831.k1.28.1-1vmw, lpfc820 ver.8.2.2.1-18vmw, qla4xxx ver. 5.01.03.2-3vmw,bfa ver. 3.0.0.0, lpfc820 ver. 8.2.0.105.34,lpfc820 ver. 8.2.1.105.34, qla2xxxver. 841.k1.28.1-1vmw, qla2xxxver. 831.k1.28.1-7vmw, qla2xxx ver.911.k1.1-19vmw, lpfc8