SternaLock Rigid Sternal System Broschüre.pdf2.4mm Power Driver Blade 2.4mm Short Blade 2.4mm...
Transcript of SternaLock Rigid Sternal System Broschüre.pdf2.4mm Power Driver Blade 2.4mm Short Blade 2.4mm...
Anticipate. Innovate.TM
SternaLock®Rigid Sternal System
SternaLock®
The New Standard For Optimal Sternal Fixation
The biomet Microfixation SternaLock® system is a Sternal Closure System that is intended for use in the stabilization and fixation of fractures of the anterior chest wall. This includes sternal fixation following sternotomy and sternal reconstructive surgical procedures to aid in the alignment and stabilization of bone. Instrumentation has been designed specifically for use with this system.
Benefits of Rigid Fixation
• Increased stability1,2
• Greater strength1
• Reduced sternal separation1
Features of the SternaLock® system
• Patent pending cuttable cross-sections for emergent re-entry
• Variety of anatomical plate designs
• Specially designed instrumentation
1 Pai S, Najmuddin J, Dupak EL, McMahon NL, Roth TP, Lalikos JF, Dunn RM, Francalancia N, Pinns GD, Billiar KL. In Vitro Comparison of Wire and Plate Fixation for Midline Sternotomies. Ann Thoracic Surgery 2005;80;962-8. Bench studies are not necessarily indicative of clinical performance.
2 Greater Stability and Earlier Bone Healing Song, HD. Agarwal JP, Jeevanadam V. Rigid Sternal fixation in the Cardiac Transplant Population. J. thoracic Cardiovascular Surg 2003; 12(3);896-7; Sargent LA, Seyfer AE, Hollinger J, Hinson RM, Graeber GM. The healing Sternum: A Comparison of Osseous Healing with Wire Verses Rigid Fixation. Ann Thoracic Surge 1991:52(3)490-4.
Description2.4mm x 8mm2.4mm x 10mm2.4mm x 12mm2.4mm x 14mm2.4mm x 16mm
Self-Drilling Locking Screws (5pk)
71-X
XXX
Sing
le P
ac
k
Part #75-640875-641075-641275-641475-6416
Description2.7mm x 8mm2.7mm x 10mm2.7mm x 12mm2.7mm x 14mm2.7mm x 16mm
Emergency Screws (5pk)
71-X
XXX
Sing
le P
ac
k
Part #75-270875-271075-271275-271475-2716
Description2.4mm Power Driver Blade2.4mm Short Blade2.4mm Standard Blade
Blades
Part #71-119171-119471-1196
DescriptionLarge Bone Reduction ForcepsBone Reduction ForcepsBeuse Plate Holding ForcepsPlate BendersPlate and Wire CutterStainless Ruler2.0/2.4mm Screw Driver Handle
Power Driver TrayPower DriverTM
Power Driver Battery
Aesculap® ContainerImplant TrayInstrument Tray
Instruments and Trays
Part #01-259524-111201-909501-972801-996013-000501-7600
15-105250-100050-1010
01-951071-130071-1306
Items to scale
SternaLock® Implants
8 Hole, X Plate 71-2623
4 Hole, Square Plate 71-2622
4 Hole,Xyphoid Plate
71-2625
4 Hole,Straight Plate
71-2636
12 Hole, Ladder Plate 71-2632
12 Hole, Wide Ladder Plate 71-2634
4 Hole,L Plate, 100°
71-2643
5 Hole, T Plate 71-2648
8 Hole, Straight Plate SP-1952
Rigid Sternal System
Anticipate. Innovate.TM
For more information on SternaLock@ or other related rvigid fixation products, please contact us at:
GLOBAL HEADQUARTERS1520 Tradeport Drive • Jacksonville, FL 32218-2480
Tel (904) 741-4400 • Toll-Free (800) 874-7711 • Fax (904) 741-4500 • Order Fax (904) 741-3059www.biometmicrofixation.com
EUROPEToermalijnring 600 • 3316 LC Dordrecht • The Netherlands
Tel +31 78 629 29 10 • Fax +31 78 629 29 12e-mail: [email protected]
What fascinates you about the body is also what drives us. That’s why we’re always pushing the boundaries of engineering to make products that help you keep the
human form as glorious as it was intended. To learn more about our breadth of products, call 800-874-7711 or visit us online at biometmicrofixation.com. We’d love to
join you in a conversation about the future.
r45k0911 BMF00-2140
As the manufacturer of this device, Biomet Microfixation does not practice medicine and does not recommend this product for use on a specific patient. The surgeon who performs any implant procedure must determine the appropriate device and surgical procedure for each individual patient. Devices shown in this brochure may not be cleared or licensed for use or sale in your individual country. Please contact your local distributor for information regarding availability of this product. Information contained in this brochure is intended for
surgeon or distributor information only and is not intended for patient distribution. All surgeries carry risks. For additional information, please see the package insert, or visit our web site at www.biometmicrofixation.com or call 1-800-874-7711. SternaLock® is a registered trademark of Biomet Microfixation. Aesculap® is a registered trademark of Aesculap Aktiengesellschaft.
Anticipate. Innovate.TM