STEP 6. In Comparability Problem and Solution or How to Change Specs

16
PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs. This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected] STEP 6. Incomparability problem and solution or how to change specs. Some time we get message Why is it happened? It is happening when we trying to create components. Let’s check specs. First we have to check default Specs. From main menu SettingsÆDefault Specs. So we have Spec – A3B-TRA. (TRA – I thinks is from word “Training”). A3B – means – ANSI 300 lb pressure. Initially we have next picture.

Transcript of STEP 6. In Comparability Problem and Solution or How to Change Specs

Page 1: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

STEP 6. Incomparability problem and solution or how to change specs.

Some time we get message

Why is it happened? It is happening when we trying to create components. Let’s check specs. First we have to check default Specs. From main menu Settings Default Specs.

So we have Spec – A3B-TRA. (TRA – I thinks is from word “Training”). A3B – means – ANSI 300 lb pressure. Initially we have next picture.

Page 2: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Let’s check specification of Pipe. From main menu select Modify Pipe Specification.

As you can see Pipe has Spec – A3B-TRA. Now we will check spec of Branch. From main menu select Modify Branch Specification.

Page 3: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

As you can see Pipe has Spec – A3B-TRA. So all of them same. Let’s complete branch creation.

Select Nozzle for Head.

Select Tail and select Nozzle for it.

Page 4: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Select other Nozzle. Now you can see dashed line of preliminary route of pipe.

Let’s remember from Step 4. That both of nozzles have specs A150. That is different than specs of pipe and branch. Click on Branch and select it. It became green (selected).

Page 5: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

From main menu Create Component. Select Forward and Autoconn. In list on left side select Assembly. (This steps explained in previous Step 5).

Click Create.

Page 6: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Click Apply.

We received message about Incompatibility problem. Let’s continue.

OK.

Page 7: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

As you can see we have problem with gasket and flange location. Let’s solve it. First delete gasket and flange. We have to change pipe in according equipment specs. If equipment already exists it means it designed to required pressure. So nozzles spec is OK. Let’s change default and Pipe specs to match with Nozzle spec. First change default spec. New components will be automatically created with this (default) spec. From main menu select Settings Default spec.

Nozzles spec is A150, but Default – A3B-TRA. Let’s change it to A150.

Page 8: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Let’s check pipe spec. Select from main menu Modify Pipe Specifications.

Page 9: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Currently is A3B-TRA. Select A150 and click Apply. Delete gasket and flange. Select by cursor flange or gasket to find it in Design explorer. Select them one by one and make right click and selected Delete.

Page 10: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

You will receive common window for confirmation.

Page 11: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

So we have clean branch.

Page 12: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

We forget to change branch specifications. Let’s check pipe spec. Select from main menu Modify Branch Specifications.

Change to A150.

Apply. Now let’s try to create flange and gasket. From main menu Create Component.

Page 13: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Select Forward and Autoconn. In list on left side select Assembly. Click Create.

Select Gasket Flange to Head. Click Apply.

Page 14: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Select required type and click OK.

So….. We did it without any error message. Let’s do same for Tail of Branch. Same way to call component creation.

Page 15: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Click Create.

Select Gasket Flange to Tail. Click Apply.

Page 16: STEP 6. In Comparability Problem and Solution or How to Change Specs

PDMS tutorial from Said: STEP 6. Incomparability problem and solution or how to change specs.

This tutorial created by Said Babanli (Azerbaijan). (Created on 05.12.08) Please send comments or additional info to mail: [email protected]

Again no probs. So…. We solved our problem with incompatibility. Try this by making different specs and solve it as described here. Good luck.