1 Status of LED Standards and Guidelines – And How Real Products are Measuring Up April 1, 2009 Kelly Gordon Pacific Northwest National Laboratory

Transcript of Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020...

Page 1: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

1

Status of LED Standards and Guidelines – And How Real Products are Measuring Up

April 1, 2009

Kelly GordonPacific Northwest National Laboratory

Page 2: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

2

What’s the status of LEDs today?

LEDsare not ready!

The truth is somewhere in between …

Let’s go all LED!

Page 3: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

3

Today’s Topics• Standards and test procedures• ENERGY STAR for SSL• How are real products performing?

– CALiPER testing results– GATEWAY demonstrations

Page 4: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

4

DOE SSL Program Strategy

Guiding technology advances fromlaboratory to marketplace

Page 5: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

5

Page 6: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

6

• ANSI C78.377-2008 Specifications for the Chromaticity of SSL Products for Electric Lamps

• IESNA LM-79-2008 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products

• IESNA LM-80-2008 Approved Method for Measuring Lumen Maintenance of LED Light Sources

Key Standardsand Test Methods

Page 7: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

7

ANSI C78.377 Scope• “…specify the range of

chromaticities recommended for general lighting with solid state lighting (SSL) products…”

• “…LED-based SSL products with control electronics and heat sinks incorporated … those devices that require only AC mains power or a DC voltage power supply to operate…”

• “…covers fixtures incorporating light sources as well as integrated LED lamps…”

Page 8: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

8

ANSI C78.377-2008

Page 9: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

9

LM-79-08 Scope• …“LED-based SSL products

with control electronics and heat sinks incorporated, […] devices that require only AC mains power or a DC voltage power supply to operate.”

Page 10: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

10

LM-79-08• Methods for measuring:

– Total luminous flux– Electrical power– Luminous intensity distribution– Chromaticity

Page 11: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

11

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA

PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

REPORT NUMBER: ITL60203 DATE: 06/03/08 Page 8 of 12PREPARED FOR: RDS

Spectral Power Distribution

0

10

20

30

40

50

60

70

80

90

350 400 450 500 550 600 650 700 750 800

Wavelength (nm)

Mill

iwat

ts p

er n

anom

eter

LUMINAIRE: FABRICATED FINNED METAL POST TOP FITTER, FOUR FABRICATED WHITE PAINTED METAL MOUNTING PLATES EACH CONTAINING CIRCUITRY AND HEAT SINKS FOR TWELVE LEDS MOUNTED IN FOUR TIERS, ONE FORMED METAL REFLECTOR WITH PREMIUM SPECULAR BOTTOM AND SPECULAR TOP ABOVE EACH TIER OF LEDS, OPEN SIDES AND BOTTOM.LAMP: FORTY-EIGHT WHITE LIGHT EMITTING DIODES EACH WITH CLEAR SEMI-HEMISPHERICAL INTEGRAL PLASTIC LENS, LEDS AIMED 11-DEGREES BELOW HORIZON.

LM-79-08 report examples

Page 12: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

12

LM-80-08 Scope• “[…] methods of measurement of lumen

maintenance of sources including LED packages, arrays and modules only.”

• “[…] does not provide guidance or make any recommendation regarding predictive estimations or extrapolation for lumen maintenance determined from actual measurements.”

Page 13: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

13

LM-80-08• Minimum 6000 hours of device

operation• Operation at three different case

temperatures– 55°C, 85°C, and one other temp

selected by manufacturer• Drive current held constant• Ambient temp within -5°C of case

temp• Humidity < 65 RH throughout test

period• Chromaticity measurements

Page 14: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

14

LM-80 – Current situation• LED device manufacturers do in-house testing• LM-80 published Sep 08 with last-minute

changes• Manufacturers transitioning to full alignment

with LM-80– New test chambers– Starting test cycles

• 6000 hours takes at least 8.3 months

Page 15: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

15

Sample LM-80 data

87.687.187.888.688.788.689.110

79.477.878.277.876.574.174.59

86.085.385.986.785.985.886.08

82.081.382.182.682.481.481.87

80.780.080.681.280.379.480.46

61.560.961.562.062.161.161.85

79.178.478.879.078.878.078.64

82.481.081.781.781.078.679.23

78.978.177.978.276.474.774.82

10005004003002001000Lamp

If = 350mA

Page 16: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

16

Standards in development – or still needed…• TM-21 – Extrapolation methodology for

lumen maintenance data• Light engine test procedure• Reliability tests for luminaires and

integral lamps• Dimming standard

Page 17: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

17

ENERGY STAR SSL

Page 18: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

18

Scope and Basic Approach

• LED systems for “white light” general illumination

• Both commercial and residential• Key metric: Luminaire efficacy• Two categories:

– Category A: prescriptive specifications for near-term lighting applications

– Category B: performance specification for all applications (long-term)

ENERGY STAR SSL

Page 19: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

19

Why a staged approach?• Ensure energy savings

– Take advantage of LED directionality• Avoid user disappointment in early

LED products• Learn from past experience

Page 20: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

2020

Category A Applications - Residential

• Undercabinet kitchen• Portable desk task• Ceiling mounted w/diffuser• Surface, pendant, recessed downlights• Cove lighting • Surface mounted with directional heads • Outdoor porch, path, step, post-top

ENERGY STAR SSL

Page 21: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

2121

Category A Applications – Non-residential

• Undercabinet shelf-mounted task• Portable desk task• Surface, pendant, recessed downlights• Wall wash luminaires• Outdoor bollards

ENERGY STAR SSL

Page 22: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

22

Example: Undercabinet shelf-mounted task lights

• Minimum Light Output– 125 lumens per lineal foot

• Zonal Lumen Density– Min. 60% in 0-60° zone– Min. 25% in 60-90° zone

• Luminaire Efficacy– ≥ 29 lm/W

• CCTs:– 2700 - 5000K

Min. 60%

Min. 25%

Min. 60%Min. 60%

Min. 25%

ENERGY STAR SSL

Page 23: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

23

Life/lumen maintenance requirements

• Hours to 70% lumen maintenance L70

• Indoor residential: min 25,000 hours• Outdoor and all non-residential: min

35,000 hours

ENERGY STAR SSL

Page 24: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

24

Qualification Process

• LM-79 luminaire photometric report• LM-80 lumen maintenance data for LEDs

used in luminaire• Luminaire in situ temperature verification

ENERGY STAR SSL

Page 25: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

25

In Situ Testing Requirement

• Life (lumen maintenance) determined by in situ temperature measurements of:– Module, Array or “Light Engine”– Power Supply/Driver

• Testing may be conducted at the same time as UL 1598.

ENERGY STAR SSL

Page 26: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

26

UL 1598 Environments

ENERGY STAR SSL

Page 27: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

27

Temperature Measurement Point (TMP)• Manufacturer designated TMP correlating

to LM-80 test report or power supply warranty– Module/Array

• Solder Joint Temperature Ts

• Case Temperature Tc

• Board Temperature Tb

– Power Supply• Case Temperature Tc

• Could also be Tb for integral Power Supplies

ENERGY STAR SSL

Page 28: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

28

Lumen Maintenance Qualification• Option 1: Component Performance

– Applicable if:• Module/Array has a current LM-80 test report• Module/Array has a designated TMP• TMP is accessible for in situ measurement

– Otherwise manufacturer must use Option 2• Option 2: Luminaire Performance

– Entire luminaire LM-79 tested at 0 and 6000 hours

ENERGY STAR SSL

Page 29: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

29

Lumen Maintenance “Passing” CriteriaA luminaire passes the L70 threshold (≥ 25,000 hours for indoor residential and ≥ 35,000 for all others) …

– if the in situ measured drive current is the same or lower

AND– if the in situ measured TMP for the

device/module/array is the same or lower

… than the LM-80 test report provided for the device/module/array.

ENERGY STAR SSL

Page 30: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

30

ENERGY STAR SSL Qualified

Kichler Design Pro Undercabinet

Page 31: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

31

ENERGY STAR SSL Qualified

Cree Lighting LR6 Downlight

Page 32: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

32

ENERGY STAR SSL Qualified

Cooper Halo Downlight

Page 33: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

33

ENERGY STAR SSL Qualified

Kichler Adjustable Rail Lights

Page 34: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

34

Possible additions to Category A• Outdoor area and roadway• Outdoor area decorative• Outdoor wall packs• Parking garage luminaires

ENERGY STAR SSL

Page 35: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

3535

Integral LED Lamps – Draft Criteria• Published Jan 16, 2009• Comments due Feb 27, 2009• 2nd round of comments • Includes:

– Omni-directional (A type)– Directional (MR,PAR type)– Decorative (candelabra type)– Lamps using ANSI bases

Page 36: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

36

Key Issues for Industry Feedback

• Dimming• Non-standard lamp forms• Low-voltage MR-16 replacements• Reliability testing

Integral LED Lamp Draft Criteria

Page 37: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

37

Directional Lamp Draft Requirements

• Applies to ANSI lamps: BR,ER,K,MR,PAR,R

• Applies to diameters: MR16, PAR16, PAR20, PAR30S, PAR30L, PAR38

• 45 lm/W• PAR and MR16 center beam intensity:

based on statistical analysis of incandescent/halogen lamps

• Min. lumens = target wattage x 10

Integral LED Lamp Draft Criteria

Page 38: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

38

Integral LED Lamp Draft Criteria

CBCP vs. Beam Angle

y = 132545x-1.4917

R2 = 0.8913

y = 6553.6e-0.0611x

R2 = 0.8141

0

2000

4000

6000

8000

0 10 20 30 40 50 60 70

Beam Angle (Degrees)

Cen

ter B

eam

Can

dlep

ower

(c

d)

SSL Measured

Halogen 20WRatings

Halogen 20WMeasured

Power (Halogen20W Ratings)

Expon. (Halogen20W Ratings)

Page 39: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

39

Statistical Analysis of Incan/Halogen →Tool for Determining Min. CBCP

• Inputs: target beam angle & wattage

• Output: Min. required CBCP

• Min. required CBCP is 2 σ below predicted value of model

Integral LED Lamp Draft Criteria

Page 40: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

40

How are real products performing?

• CALiPER Testing

• GATEWAY Demonstrations

Page 41: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

41

• Lots of marketing hype, but where do we get the truth?– Which products are good? Which products aren’t?– How do they compare to what we know?– How do we avoid the early negative CFL experience?

SSL Luminaires and Replacement Lamps

Page 42: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

42

Scope• SSL • General

illumination• White light• Market-

available

Page 43: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

43

CALiPER Testing: Measurable Progress

0

10

20

30

40

50

60

70

80

CALiPER Results Over Time

Ave

rage

Effi

cacy

of S

SL (l

m/W

) Vertical lines show range from best to worst luminaire efficacy

2006 2009

12/065/076/0712/07

6/089/0810/011/09

1/085/08

Page 44: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

44

Recent CALiPER Testing: Round 7• Outdoor Fixtures

– Streetlights– Bollards

• Downlights• Replacement lamps

– Directional (MR16, PAR…)– Omni-directional (A-lamp)

• Side-by-side comparisons

Page 45: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

45

Outdoor Applications

Page 46: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

46

Streetlights comparison

0.9977425349339870Induction 20.9675390655382869Induction 10.44212042566540117HPS 0.9972310133310595SSL 50.9968521070258837SSL 40.9972605247344073SSL 30.9975622755317958SSL 20.93741462819102855SSL 1

PFCRICCTlm/WLumensW

Page 47: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

47

SSL

CFL

MH

0

200

400

600

800

0 4 8 12 16 20

Luminaire Efficacy

Lum

inai

re O

utpu

t

Bollards Side-by-Side Comparison

Same ModelSimilar DistributionWith House-Side Shield

Page 48: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

48

Downlights

Page 49: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

49

0

300

600

900

1200

1500

1800

0 10 20 30 40 50 60 70Efficacy (lumens/Watts)

Ligh

t Out

put (

lum

ens)

Round 7 SSL Fixtures, 10-42W

SSL Fixtures andReplacement Lamps 3-40W

Incandescent BR and A-lamps, 45-75W

Halogen PAR38 (FL and IR)Lamps, 50-60W

CFLs (spiral, pin, CCFL, &reflector), 9-43W

Incandescents & Halogens

CFL

SSL

SSL Downlight Performance

Page 50: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

50

SSLCFL

0

500

1000

1500

2000

0 10 20 30 40 50 60

Luminaire Efficacy (lm/W)

Lum

inai

re O

utpu

t (lm

)

Downlights Side-by-Side Comparison

Same Model1’ x 1’ SquareVolumetric Recessed LightingSame Color QualitySimilar DistributionSSL Initial Cost ≈ 2 x CFL Initial Cost

Page 51: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

51

San Francisco

Minneapolis

Atlantic City

Oakland

Demos

Portland

Page 52: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

52

LED Street Light Assessment - Oakland• Emerging Technologies

Field Assessment– Collaboration with PG&E,

DOE, City of Oakland, Beta LED

– Basecase: 100 W HPS – Phase 2

• November 2007• 3-bar Beta LED Edge

– Phase 3 • July 2008 • Beta LEDWay

www.etcc-ca.com or www.ssl.energy.gov

Page 53: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

53

LED Street Light Assessment - Oakland• Measured Power Consumption

52%

6358

Phase 3 LED

36%

4378

Phase 2 LED

Savings

HPSFixture

Percent Reduction

121Power (W)

Source: PG&E Emerging Technologies Assessment

Page 54: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

54

LED Street Light Assessment - Oakland• Lighting Performance

6.5:10.191.210.58Phase 2 LED

6.5:1

19.0:1

Max to Min

1.21

3.53

Max Illum(fc)

0.19

0.19

Min Illum(fc)

0.50

1.00

AvgIllum(fc)

Fixture

Phase 3 LED

HPS

Source: PG&E Emerging Technologies Assessment

Page 55: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

55

LED Street Light Assessment - Oakland

Source: PG&E Emerging Technologies Assessment

HPS Phase 2 LED Phase 3 LED

Page 56: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

56

LED Street Light Assessment - Oakland• Customer Acceptance

– 60 households contacted– 20 noticed the new lights– 70% preferred LED lights– Perceived improved visibility, overall appearance

and nighttime safety

Source: PG&E Emerging Technologies Assessment

Page 57: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

57

LED Street Light Assessment - Oakland• Economic Performance

~20$42$833Phase 2 LED$52

$0

Total Annual Savings

($/yr)

~12

NA

Estimated Payback (yr)

$605

$0

Installed Cost ($)

Retrofit Scenario

Phase 3 LED

HPS

Source: PG&E Emerging Technologies Assessment

Page 58: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

58

Streetlight payback estimates

Group ReplacementEstimate: 25.5 years

Spot ReplacementEstimate: 19.8 years

Group: 14.2 years

Spot: 11.6 years

Spot: 5.0 yearsGroup: 6.1 years

0

5

10

15

20

25

30

35

40

$0 $20 $40 $60 $80 $100

Total Annual Maintenance Savings Estimate (USD)

Simple Payback (Years)

Phase II (Retrofit)

Phase III (Retrofit)

Phase III (New Construction)

Oakland Streetlighting Demonstration Phase III

Page 59: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

59

LED Street Light Assessment - Oakland• Progress in 12 Months

– Cost reduced 34%– Energy consumption reduced by 20 W

(25%) – Lighting performance maintained

• Same LEDs, better engineeringSource: PG&E Emerging Technologies Assessment

Page 60: Status of LED Standards and Guidelines – And How Real ...€¦ · CFL 0 500 1000 1500 2000 0 1020 30405060 Luminaire Efficacy (lm/W) Luminaire Output (lm) Downlights Side-by-Side

60

Questions?

DOE SSL Website: www.ssl.energy.gov