State of Connecticut Septic Allowance CULTEC Contactor® and Recharger® Plastic Septic Chambers As Replacements for Concrete Leaching Galleries Leaching gallery rows shall be installed level and follow ground contours. Leaching galleries shall be hollow structures with perforated or open joint sides and tight covers, and 12 inches of approved aggregate shall be placed on the sides of concrete galleries and on the ends of the gallery rows. Leaching galleries shall provide a minimum 40 inches of open bottom width. The sidewalls shall have a minimum depth of 12 inches and a maximum depth of 4 feet, including up to 6 inches of approved aggregate above the top of the structure. Whenever approved aggregate is placed on top of the structure for additional credit, the distribution pipe should be located in the approved aggregate above the structure if feasible. Stone aggregate backfill for concrete galleries shall meet the No. 4 stone aggregate gradation. The width of the trench excavation shall not be less than 6 feet and the width of the hollow structure(s) shall be not less than 4 feet. The bottom of each leaching gallery row shall be level, and the total length of excavated gallery row shall be utilized to calculate effective area. Model Gallery Height (inches) Effective Leaching Credit (SF/LF) Center to Center Spacing (feet) Recharger 900HD 1 48 13.3 15 Recharger 900HD 2 48 11.3 15 Recharger 330XLHD 3 36 8.0 12 Recharger 330XLHD 30 7.4 12 Recharger 280HD 4 27 7.1 12 Twin Recharger 180 and 180HD 5 24 6.8 12 Twin Contactor 100 and 100HD 12 5.9 12 Contactor Field Drain C4 and C4HD 5 12 5.9 12 1 Recharger 900HD lined/covered with approved filter fabric and backfilled with select fill. 2 Recharger 900HD backfilled with approved aggregate. 3 Recharger 330XLHD requires 5.5” of stone over the top of the unit to be considered an equivalent. 4 Recharger 280HD required 0.5” of stone over the top of the unit to be considered an equivalent. 5 Recharger 180 and Contactor Field Drain C4 require 3.5” of stone above the unit to be considered an equivalent. For the purposes of Section VIII F & G, the effective leaching area of gallery rows and corresponding minimum center to center spacing between rows shall be as follows: Single plastic chambers (i.e., Cultec Recharger 330XL HD) or multiple plastic chambers may be utilized in a gallery configuration as long as the minimum open bottom width is provided, and the proprietary leaching system company authorizes such installation practice. Stone aggregate backfill for plastic chambers shall meet the No. 4 or No. 6 stone aggregate gradation. Plastic Leaching Chambers Backfilled with Approved Aggregate The following chambers cannot be backfilled with select fill unless the chambers are lined/covered with filter fabric (See Section VIII E 7 for ELA). The chambers can be used without being lined/covered by filter fabric, however the chambers shall be backfilled with approved aggregate. For the purpose of Section VIII F & G, the effective leaching area of the approved products listed below and minimum center to center spacing shall be as follows: Model Dimensions (WxH) Effective Leaching Area (SF/LF) Center to Center Spacing (feet) Contactor EZ24 and EZ24HD 16” x 12” 1.9 7 Contactor EZ24 and EZ24HD (PDS) 16” x 12” 2.5 7

Transcript of State of Connecticut Septic Allowance - CULTEC,...

Page 1: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

State of Connecticut Septic Allowance 

CULTEC Contactor® and Recharger® Plastic Septic Chambers 

As Replacements for Concrete Leaching Galleries Leaching gallery rows shall be installed level and follow ground contours.  Leaching galleries shall be hollow structures with perforated or open joint sides and tight covers, and 12 inches of approved aggregate shall be placed on the sides of concrete galleries and on the ends of the gallery rows.  Leaching galleries shall provide a minimum 40 inches of open bottom width.  The sidewalls shall have a minimum depth of 12 inches and a maximum depth of 4 feet, including up to 6 inches of approved aggregate above the top of the structure.  Whenever approved aggregate is placed on top of the structure for additional credit, the distribution pipe should be located in the approved aggregate above the structure if feasible.  Stone aggregate backfill for concrete galleries shall meet the No. 4 stone aggregate gradation.  The width of the trench excavation shall not be less than 6 feet and the width of the hollow structure(s) shall be not less than 4 feet.  The bottom of each leaching gallery row shall be level, and the total length of excavated gallery row shall be utilized to calculate effective area.  

Model  Gallery Height            (inches) 

Effective Leaching Credit (SF/LF) 

Center to Center Spacing (feet) 

Recharger 900HD1  48  13.3  15 

Recharger 900HD2  48  11.3  15 

Recharger 330XLHD3  36  8.0  12 

Recharger 330XLHD  30  7.4  12 

Recharger 280HD4  27  7.1  12 

Twin Recharger 180 and 180HD5  24  6.8  12 

Twin Contactor 100 and 100HD  12  5.9  12 

Contactor Field Drain C‐4 and C‐4HD5  12  5.9  12  

1 Recharger 900HD lined/covered with approved filter fabric and backfilled with select fill. 2 Recharger 900HD backfilled with approved aggregate.  3 Recharger 330XLHD requires 5.5” of stone over the top of the unit to be considered an equivalent. 4 Recharger 280HD required 0.5” of stone over the top of the unit to be considered an equivalent. 5 Recharger 180 and Contactor Field Drain C‐4 require 3.5” of stone above the unit to be considered an equivalent.  

For the purposes of Section VIII F & G, the effective leaching area of gallery rows and corresponding minimum center to center spacing between rows shall be as follows: Single plastic chambers (i.e., Cultec Recharger 330XL HD) or multiple plastic chambers may be utilized in a gallery configuration as long as the minimum open bottom width is provided, and the proprietary leaching system company authorizes such installation practice. Stone aggregate backfill for plastic chambers shall meet the No. 4 or No. 6 stone aggregate gradation.  Plastic Leaching Chambers Backfilled with Approved Aggregate The following chambers cannot be backfilled with select fill unless the chambers are lined/covered with filter fabric (See Section VIII E 7 for ELA). The chambers can be used without being lined/covered by filter fabric, however the chambers shall be backfilled with approved aggregate. For the purpose of Section VIII F & G, the effective leaching area of the approved products listed below and minimum center to center spacing shall be as follows:  Model  Dimensions         

(WxH) Effective Leaching Area 

(SF/LF) Center to Center Spacing 

(feet) 

Contactor EZ‐24 and EZ‐24HD  16” x 12”  1.9  7 

Contactor EZ‐24 and EZ‐24HD (PDS)  16” x 12”  2.5  7 

Page 2: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

Contactor 100 and 100HD  36” x 12.5”  3.7  7 

Contactor 100 and 100HD (PDS)  36” x 12.5”  4.3  7 

Recharger 180 and 180HD  36” x 20.5”  4.4  7 

Recharger 180 and 180HD (PDS)  36” x 20.5”  5.1  9 

Recharger 280HD  46” x 26.5 ”  6.5  10 

Recharger 280HD (PDS)  46” x 26.5 ”  7.1  10 

Recharger 330XLHD  52” x 30.5”  5.6  11 

Corrugated Leaching Systems Lined/Covered with Filter Fabric Units shall be lined/covered with filter fabric and backfilled with select fill.  For the purpose of Section VIII F & G, the effective leaching area of the approved products listed below and corresponding minimum center to center spacing shall be as follows:  Model  Dimensions         

(WxH) Effective Leaching Area 

(SF/LF) Center to Center Spacing 

(feet) 

Contactor EZ‐24 and EZ‐24HD  16” x 12”  1.9  7 

Contactor EZ‐24 and EZ‐24HD (PDS)  16” x 12”  2.5  7 

Contactor 100 and 100HD  36” x 12.5”  3.7  7 

Contactor 100 and 100HD (PDS)  36” x 12.5”  4.3  7 

Recharger 180 and 180HD  36” x 20.5”  4.4  7 

Recharger 180 and 180HD (PDS)  36” x 20.5”  5.1  9 

Recharger 280HD  46” x 26.5 ”  6.5  10 

Recharger 280HD (PDS)  46” x 26.5 ”  7.1  10 

Recharger 330XLHD  52” x 30.5”  5.6  11 

The above Cultec fabric‐lined chambers shall be backfilled with select fill to receive full credit.  A 0.4 SF/LF ELA reduction shall be assessed if the chambers are backfilled with soil not meeting select fill gradation requirements.  Referenced:  CONNECTICUT PUBLIC HEALTH CODE On‐site Sewage Disposal Regulations, and Technical Standards for Subsurface Sewage Disposal Systems Revised January 1, 2011  State of Connecticut Cultec, Inc. Recharger 900HD Proprietary Leaching Product Approval  Dated June 23, 2014  

      

   

CULTEC, Inc. P.O. Box 280, 878 Federal Road 

Brookfield, CT 06804 203‐775‐4416 

www.cultec.com [email protected] 

Page 3: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Contactor® & Recharger® Septic Chambers Chamber of Choice™

Product Bookletfor CULTEC Septic Leachfi eld Systems

Page 4: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Septic Leachfi eld Systems 101 - The Basics

A septic system achieves sewage treatment and disposal for rural homes where centralized sewage systems may not be available. It is composed of a septic tank and a drainfi eld. The sewage fl ows from the house to the septic tank where the solids are removed; the wastewater then fl ows to the drainfi eld where it is allowed to soak into the ground.

The drainfi eld (leachfi eld, disposal trench or subsurface disposal fi eld) is an underground conduit network buried below the surface of the ground. The fi eld distributes the effl uent from the septic tank over a large area allowing it to percolate through the soil.

Conventional drainfi elds have used perforated pipe and stone systems or concrete galleries to distrib-ute the effl uent. CULTEC’s Contactor® and Recharger® plastic chambers may be used in place of these conventional systems for more effective installation.

Our plastic septic chambers have been widely accepted in most parts of the United States for gravel-less septic leachfi elds as replacements for concrete galleries and conventional pipe and stone sys-tems. Contact area is maximized by the fully open bottoms, perforated sidewalls, and the use of CULTEC No. 410™ Filter Fabric.

Due to their greater contact area, CULTEC chambers are commonly allowed to reduce the overall system sizing requirements up to 50% when approved by the local authority. (Check your local septic code.)

This sizing reduction may be a key factor when choosing septic products for a residence with tight site constraints, existing landscaping or when area is desired for other structures such as a swimming pool.

Features• Perforated sidewalls and open bottom promote infi ltration• Patented overlapping rib connection• Optional inspection port opening on each unit• Heavy Duty units meet traffi c application criteria when installed per manufacturer's recommen-

dations• Repeating support panel adds to strength of installation• Lightweight• Variety of sizes available• No separate end plates required• Integrated internal and external pipe supports• Chemically resistant• Manufactured in ISO 9001:2008 certifi ed facilities

System Benefi ts• Less land area required• Greater contact with primary leaching area promotes maximum infi ltration capabilities• Lightweight• Gravel-less installation allows for less heavy equipment time• Patented overlapping rib connection is fast and easy to install• Long structural life expectancy• Able to transport in a pick up truck• System sizing reductions allowed in most areas (Check your local septic code.)

Product Information

2

Page 5: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Product Information

3

Gravel-less septic application using CULTEC chambers and CULTEC No. 410™ fi lter fabric.Lightweight chambers minimize heavy equipment time and labor.

Page 6: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Chamber and Filter Fabric - A Two-Part SystemUse of a non-woven polypropylene fi lter fabric is required for CULTEC Contactor® and Recharger® septic installations to pre-vent soil intrusion and promote infi ltrative capability.

For CULTEC gravel-less septic systems, the fi lter fabric is placed directly over the chamber.

For septic installations using stone, the fi lter fabric is placed over the top of the stone prior to fi nal backfi lling.

CULTEC distributes its own CULTEC No. 410™ Filter Fabric to be used with the Contactor® and Recharger® septic chambers.

Substituted fabrics must meet or exceed the properties of the CULTEC No. 410™ Filter Fabric listed below in order to not void the warranty.

Properties Test Method Test Results

Appearance Black

Grab Tensile D 463290 lbs

400 N

Elongation D 4632 50%

Trapezoid Tear D 453335 lbs

155 N

Puncture D 483355 lbs

245 N

Mullen Burst D 3786175 psi

1205 kPa

AOS D 475170 U.S. sieve

.21 mm

Permittivity D 4491 2.0 sec-1

Permeability D 4491 .2 cm/sec

Water Flow D 4491145 gal/min/sf

5908 l/min/sq.mt

UV Stability D 4355 70%

Design Information

4

Page 7: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC promotes the placement of perforated pipe along the top of the outside of their septic chambers. A fi lter fabric covering is then placed over the pipe and chamber. This method of in-stallation is called a Pipe Distribution System or PDS system.

Wastewater is discharged through the perfora-tions of the pipe directly onto the fi lter fabric. The fi lter fabric works as a sponge and absorbs the effl uent and increases the total surface area of the septic system through capillary action. Overall concentration of effl uent per square foot is thereby decreased.

When the pipe is on top of the unit, the sus-pended solids settle out on the outside of the chamber between the fabric and the sidewall bottom of the unit. This allows for the open bottom within the chamber to perform at maximum effectiveness since it is not being contaminated by the settling out of particles.

The effectiveness of the primary leaching base area is increased by allowing suspended solids to settle on the outside of the chamber rather than contaminating the open bottom area beneath the chamber.

A PDS system may either be a gravity system that relies on gravity to distribute the effl uent or may be a pressure distribution system that employs a lift station with a pump to dispense the wastewater to the leachfi elds.

This method of installation may not be approved in all areas, check with your local septic code.

Pipe Distribution Systems - PDS

Design Information

5

Page 8: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

The Contactor® Chamber series con-sists of lower profi le, lower capacity chambers used for septic installations with depth restrictions or where larger units are may not approved by the lo-cal authority.

The Recharger® Chamber series consists of higher profi le, higher capacity chambers. Fewer units are required resulting in a smaller overall footprint, where approved.

Design Information

CULTEC Contactor® & Recharger® Chamber Specifi cation Information

Contactor®

EZ-24Contactor®

Field Drain C-4

Contactor® 100

Contactor® 100HD

Recharger® 150XLHD

Recharger®

180HDRecharger®

280HDRecharger® 330XLHD

Length8.5' 8.5' 8' 8' 11' 7.33' 8' 8.5'

2.59 m 2.59 m 2.44 m 2.44 m 3.35 m 2.23 m 2.44 m 2.59 m

Installed Length8' 8' 7.4' 7.5' 10.25' 6.33' 7' 7'

2.44 m 2.44 m 2.29 m 2.29 m 3.12 m 1.93 m 2.13 m 2.13 m

Width16" 48" 36" 36" 33" 36" 47" 52"

406 mm 1219 mm 914 mm 914 mm 838 mm 914 mm 1194 mm 1321 mm

Height12" 8.5" 12.5" 12.5" 18.5" 20.5" 26.5" 30.5"

305 mm 216 mm 318 mm 318 mm 470 mm 673 mm 673 mm 775 mm

Invert Height6" 3" 6" 6" 12" 14" 20.5" 24"

152 mm 76 mm 152 mm 152 mm 305 mm 356 mm 521 mm 610 mm

Field Drain C-4 EZ-24 100 100HD

150XLHD 180HD 280HD 330XLHD

6

150XLHD 180HD

Page 9: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

End Detail Information

Large RibEnd Detail

Small RibEnd Detail

Model R (or RHD for heavy duty version) is a starter / stand alone unit with two full endwalls. They are used to start lines or can be used singularly.

Model E (or EHD for heavy duty version) is a middle / end unit with one closed endwall and one open end. They are used to continue lines and also used to end a line.

CULTEC Typical Installation Method

Model R

Model E

Interlock Model R to E using the patented overlapping rib connection.

• Start each line with a Model R.• Use Model E to continue the length of your line.• End your line by using a Model E.

Hidden End

Model R

Model E

Model E

Model E

Design Information

The patented overlapping rib connection used by CULTEC's chambers permit a curved line of instal-lation. This is a benefi cial quality when following land contours or a sweep around an obstruction is necessary.

7

Page 10: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Contactor® EZ-24™

Technical Information

The Contactor® EZ-24™ is a low profi le, low capacity chamber. It is able to bend around obstacles with a defl ection capability of 25’ per 100’ (7.62 m per 30.5 m).

Size (L x W x H) 8.5' x 16" x 12"2.59 m x 407 mm x 305 mm

Installed Length 8'2.44 m

Length Adjustment per Run 0.5'0.15 m

Invert Height 6"152 mm

Top View

Side View

Front View

8

Top View

Side View

Front View

Page 11: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Contactor® Field Drain C-4™

Technical Information

The Contactor® Field Drain C-4™ is our lowest profi le septic cham-ber with largest bottom area infi ltrative capability.

Size (L x W x H) 8.5' x 48" x 8.5"2.59 m x 1219 mm x 216 mm

Installed Length 8'2.44 m

Length Adjustment per Run 0.5'0.15 m

Invert Height 3"76 mm

Front View

Top View

Side View

9

Front View

Top View

Side View

Page 12: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Contactor® 100™

The Contactor® 100™ is currently our most popular low profi le septic chamber. It typically meets most 3’ wide septic code regula-tions.

Size (L x W x H) 8' x 36" x 12.5"2.44 m x 914 mm x 318 mm

Installed Length 7.4'2.26 m

Length Adjustment per Run 0.6'0.18 m

Invert Height 6"152 mm

Top View

Side View

Front View

Technical Information

10 more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Top View

Side View

Front View

Page 13: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Technical Information

Side View

Front View

Top View

11

CULTEC Contactor® 100HD™

The Contactor® 100HD™ is currently our most popular low profi le septic chamber. It typically meets most 3’ wide septic code regula-tions.

Size (L x W x H) 8' x 36" x 12.5"2.44 m x 914 mm x 318 mm

Installed Length 7.5'2.29 m

Length Adjustment per Run 0.5'0.15 m

Invert Height 6"152 mm

Page 14: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Recharger® 150XLHD™

Technical Information

The Recharger® 150XLHD™ is a 18.5" (470 mm) midsize chamber used for septic leachfi elds.

Size (L x W x H) 11' x 33" x 18.5"3.35 m x 838 mm x 470 mm

Installed Length 10.25'3.12 m

Length Adjustment per Run 0.75'0.23 m

Invert Height 12"305 mm

Top View

Side View

Front View

12

Top View

Side View

Front View

Page 15: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Recharger® 180HD™

Technical Information

The Recharger® 180HD™ is a 20.5" (521 mm) tall, mid-size cham-ber used for septic leachfi elds.

Size (L x W x H) 7.33' x 36" x 20.5"2.23 m x 914 mm x 521 mm

Installed Length 6.33'1.93 m

Length Adjustment per Run 1'0.30 m

Invert Height 14"356 mm

Front View

Top View

Side View

13ore information contact CULTEC at (203) 775-4416 or visit www cultec

Front View

Top View

Side View

Page 16: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Recharger® 280HD™

Technical Information

The Recharger® 280HD™ is a 26.5" (673 mm) tall, mid-size cham-ber used for septic leachfi elds.

Size (L x W x H) 8' x 47" x 26.5"2.44 m x 1194 mm x 673 mm

Installed Length 7'2.13 m

Length Adjustment per Run 1'0.30 m

Invert Height 20.5"521 mm

Top View

Side View

Front View

14

Top View

Side View

Front View

Page 17: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Recharger® 330XLHD™

Technical Information

The Recharger® 330XLHD™ is a 30.5" (775mm) tall, high capacity chamber used for septic leachfi elds.

Size (L x W x H) 8.5' x 52" x 30.5"2.59 m x 1321 mm x 775 mm

Installed Length 7'2.13 m

Length Adjustment per Run 1.5'0.46 m

Invert Height 24"610 mm

Side View

Front View

Top View

15

Page 18: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

CULTEC Recharger® 900HD™

Technical Information

The Recharger® 900HD™ is a 48" (1219 mm) tall, jumbo-sized chamber used for septic leachfi elds.

Size (L x W x H) 9.25' x 78" x 48"2.82 m x 1981 mm x 1219 mm

Installed Length 7'2.13 m

Length Adjustment per Run 2.25'0.69 m

Invert Height 40"1016 mm

Top View

Side View

Front View

16

Page 19: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.

Chamber of Choice™

CULTEC, Inc.878 Federal Road • P.O. Box 280 • Brookfi eld, CT 06804

Phone: 203-775-4416 • Toll Free: 1-800-4-CULTEC • Fax: 203-775-1462Web: www.cultec.com • E-mail: [email protected]

CULG009 10-13

Protected by one or more of the following patents: U.S. Patent No. 5,419,838; 6,129,482; 6,322,288 B1; 7,226,241; 8,425,148 B2 ; Canadian Patent No. 2,252,286; 2,450,565; 2,591,255; 2,303,658; Other U.S. and/or Foreign patent(s)/patent(s) pending. European Design Nos. 001092191 (0001-0004).

CULTEC®, RECHARGER®, and CONTACTOR® are trademarks of CULTEC, Inc.

Copyright 2013 CULTEC, Inc. All rights reserved. The drawings, photographs and illustrations shown in this document are for illustrative purposes only and are not necessarily to scale. Actual designs may vary.

CULTEC reserves the right to make design and/or specifi cation changes at any time without notice at CULTEC’s sole discretion.Some installation photos courtesy of T. Edward & Son Co., LLC

Limited 1-Year WarrantyCULTEC, Inc. fi nished products, when properly installed, registered with Cultec, Inc., and operated under normal conditions of use, are covered under Cultec Inc.’s Limited Warranty to be free from defects in material and workmanship for a period of one (1) year from the date of manufacture. In order to obtain Cultec’s Limited Warranty, the product warranty registration card must be completed and returned to Cultec, Inc., having been postmarked within thirty (30) days of installation. Failure to return the warranty registration card to Cultec, Inc. shall void the Limited Warranty. This Limited Warranty shall be void if the fi nished product is not installed within forty-fi ve (45) days of the date of purchase from Cultec, Inc. In order to obtain performance under this Limited Warranty, Cultec, Inc. must be provided with written notice of any defect promptly (in no case later than ten (10) business days after initial discovery AND prior to the end of the Limited Warranty period), with such notice sent to 878 Federal Road, PO Box 280, Brookfi eld, CT 06804-0280. The original purchase receipt for the product must be included with documentation supporting any claim under the terms of this Limited Warranty. Failure to promptly submit notice of defect, a receipt and completed limited warranty certifi cate will void the Limited Warranty. Cultec, Inc. shall not be responsible for any freight charges incurred in connection with this Limited Warranty. A fee may be incurred when Cultec, Inc. (in its sole discretion) deems it necessary for a Cultec, Inc. representative to visit a product installation site.

This Limited Warranty extends only to Cultec, Inc. products when the products are installed in ‘single level’, provided that such products do not, in the collective, amount to more than 12,000 cubic feet (339.84 cubic meters) of water volume storage capacity. This Limited Warranty shall be void where prod-ucts are installed in ‘multi-layer’ or ‘multi-tier’ systems, as well as wherein collective system volume exceeds 12,000 cubic feet (339.84 cubic meters) of water volume storage capacity. Notwithstanding the foregoing, Cultec, Inc., in its sole discretion, may extend certain Limited Warranty terms upon ‘double-layer’ or ‘double-tier’ product installations, as well as ‘single level’ product installations wherein collective system volume exceeds 12,000 cubic feet (339.84 cubic meters) of water volume storage capacity, provided that (i) the buyer has contacted Cultec, Inc. prior to installation and has advised of the proposed installation design; (ii) all product warranty registration information has been provided prior to product installation; (iii) a pre-construction/pre-installation meeting has been held with representatives of Cultec, Inc.; and (iv) Cultec, Inc. has provided written confi rmation of its intent to honor any Limited War-ranty terms with respect to the specifi c installation. Under no circumstances shall any decision by Cultec, Inc. to honor such terms be relied upon by any party in any subsequent product purchase or installation.

This Limited Warranty does not apply to installation piping and/or other parts not supplied by Cultec, Inc. Cultec, Inc.’s limited warranties also do not extend to any goods or parts which have been damaged prior to installation, subjected to misuse, damaged by lack of maintenance, improper installation, neglect, damaged by accident, or damaged by being crushed by heavy equipment weighing in excess of the rated load carrying capacity of the product. This Limited Warranty also does not apply to shipping or in-transit damage.

THIS LIMITED WARRANTY DOES NOT APPLY TO CULTEC, INC. PRODUCTS THAT HAVE NOT BEEN INSTALLED ACCORDING TO CULTEC WRITTEN INSTALLA-TION INSTRUCTIONS. ANY PRODUCT DAMAGE OR FAILURE RESULTING FROM IMPROPER OR NEGLIGENT INSTALLATION IS SPECIFICALLY EXCLUDED FROM THIS WARRANTY AND SHALL REMAIN THE BUYER’S RESPONSIBILITY.

THIS WARRANTY IS LIMITED TO THE BUYER AND IS NOT TRANSFERABLE. THIS EXPRESS LIMITED WARRANTY EXCLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESSED, IMPLIED, OR STATUTORY, BY ANY LITERATURE, DATA, OR PERSON. CULTEC, INC. EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD. THERE ARE NO WARRANTIES WHICH EX-TEND BEYOND THE DESCRIPTIONS SET FORTH IN THIS LIMITED WARRANTY, NOTWITHSTANDING ANY KNOWLEDGE OF CULTEC, INC. REGARDING THE USE OR USES INTENDED TO BE MADE OF GOODS, PROPOSED CHANGES OR ADDITIONS TO GOODS, OR ANY ASSISTANCE OR SUGGESTIONS THAT MAY HAVE BEEN MADE BY CULTEC, INC. PERSONNEL. BUYER IS RESPONSIBLE FOR DETERMINING THE SUITABILITY OF CULTEC, INC. PRODUCTS FOR BUYER’S USE OR RESALE, OR FOR INCORPORATING THEM INTO OBJECTS OR APPLICATIONS WHICH BUYER DESIGNS, ASSEMBLES, CONSTRUCTS OR MANUFACTURES.

CULTEC, INC. WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, HOWEVER ARISING, INCLUDING BUT NOT LIMITED TO THOSE FOR USE OF ANY PRODUCTS, LOSS OF TIME, INCONVENIENCE, LOST PROFIT, LABOR CHARGES, OR OTHER INCIDENTAL OR CON-SEQUENTIAL DAMAGES WITH RESPECT TO PERSONS, BUSINESS, OR PROPERTY, WHETHER AS A RESULT OF BREACH OF WARRANTY, NEGLIGENCE OR OTH-ERWISE. NOTWITHSTANDING ANY OTHER PROVISION OF THIS LIMITED WARRANTY, BUYER’S REMEDY AGAINST CULTEC, INC. FOR GOODS SUPPLIED OR FOR NON-DELIVERED GOODS OR FAILURE TO FURNISH GOODS, WHETHER OR NOT BASED ON NEGLIGENCE, STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY, IS LIMITED SOLELY, AT CULTEC, INC.’S OPTION, TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON-DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS. CULTEC, INC.’S MAXIMUM LIABILITY UNDER THIS EXCLUSIVE REMEDY SHALL NEVER EXCEED THE COST OF THE SUBJECT PRODUCT. CULTEC, INC. RESERVES THE RIGHT, AT ITS SOLE DISCRETION, TO REFUND THE PURCHASE PRICE IN LIEU OF REPAIR OR REPLACEMENT.

Page 20: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

1

Contactor® & Recharger® Septic Chambers

Septic Installation Guide Book

Page 21: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

2

CULTEC Septic Chambers

Published byCULTEC, Inc.P.O. Box 280878 Federal RoadBrookfield, Connecticut 06804 USAwww.cultec.com

Copyright Notice © 2014 CULTEC, Inc. All rights reserved. Printed in the USA.This document and any accompanying CULTEC products are copyrighted by CULTEC, Inc. Any re-production and/or distribution without prior written consent from CULTEC, Inc. is strictly prohibited.

Disclaimers: The drawings, photographs and illustrations shown in this document are for illustrative purposes only and are not necessarily to scale. Actual designs may vary.

CULTEC reserves the right to make design and/or specification changes at any time without notice at CULTEC’s sole discretion.

CULTEC is not responsible for typographical errors.

Protected by one or more of the following patents:U.S. Patents 6,129,482; 6,322,288; 6,854,925; 7,226,241; 7,806,627; 8,366,346; 8,425,148; and others; U.S. Designs D613819; D638,095; D668,318 and others; Canadian Patent 2,591,255 and others; Community Designs 1092191; 1745209; and others. CULTEC, the CULTEC logo, RECHARGER, CONTACTOR, HVLV, PAC, STORMFILTER, STORMGENIE and The Chamber with The Stripe are registered trademarks of CULTEC, Inc.Chamber of Choice, 902, HD, 100, 125, 150, 150XL, 180, 280, 330, 330XL, V8, 900, Field Drain Pan-el, C-1, C-2, C-3, C-4, EZ-24, Landscape Series are trademarks of CULTEC, Inc. All rights reserved.

Contact Information:For general information on our other products and services, please contact our offices within the United States at (800)428-5832, (203)775-4416 ext. 2002, or email us at [email protected].

For technical support, please call (203)775-4416 ext. 2003 or email [email protected].

Doc ID: CULG066 05-14May 2014You are using version CULG066 05-14 of our CULTEC Septic Installation Guide Book.

Page 22: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

3

CULTEC Chambers: The Standard in Leachfields

The CULTEC Contactor® and Recharger® chambers are the alternative to conventional pipe and stone or concrete leachfield systems. They may be installed in trench, trench with pipe distribution system (PDS), bed or field or gallery design per applicable state code. Contact area is maximized by the fully open bottoms, perforated sidewalls, and use of CULTEC No. 410™ Filter Fabric. The CULTEC No. 410™ Filter Fabric wicks moisture, wetting the entire surface area of the chambers and prevents soil intrusion. Gravity feed or pressure distribution is made easy by the chamber’s built-in features.

A typical CULTEC gravelless septic system consists of: • Septic tank • Distribution box(es) • Pipe • CULTEC Contactor® or Recharger® chambers • CULTEC No. 410™ Filter Fabric, or approved equal

System benefits: • Reduced soil absorption system area, where allowed • Greater contact with primary leaching area promotes maximum infiltration capabilities of soil • Lightweight • Gravelless installation allows for less heavy equipment time • Overlapping rib connection is fast and easy to install • Long structural life expectancy

Additional advantage provided by CULTEC No. 410™ Filter Fabric: • A high degree of capillary distribution of effluent and ability to discharge into the surrounding soil • When effluent impinges upon the fabric, it is quickly absorbed and interfaced with a greater total soil area than a trickle down gravity distribution system

Trench installation demonstrating minimal disturbance of land.

Page 23: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

4

CULTEC Chamber Product Lines

The CULTEC Contactor® Series Available in Standard and Heavy Duty versions.

The CULTEC Recharger® Series Only available in Heavy Duty version.

Note: Contact CULTEC or your local health department to determine which chambers are approved for septic use in your area.

CULTEC Septic Chambers

150XLHD 180HD 280HD 330XLHD

Field Drain C-4 EZ-24 100 100HD

900HD

Page 24: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

5

Straight Line Deflection of CULTEC Chambers The patented overlapping rib connection used by CULTEC’s Contactor®, Recharger® and Field Drain™ chambers permit a curved line of installation. This is a beneficial quality when following land contours or when a sweep around an obstruction is necessary.

Contactor® EZ-24 Special Flex Design

Model Deflection (per 100’)

Contactor® Field Drain™ C-4 and C-4HD 1’

Contactor® EZ-24 and EZ-24HD 25’

Contactor® 100 and 100HD 6’

Recharger® 150XLHD 5’

Recharger® 180HD 6’

Recharger® 280HD 6’

Recharger® 330XLHD 5’

Page 25: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

6

Preparation • Following standard construction practices, prepare the trench according to state and local codes. • Excavate to a width and length sufficient to fit the number of chambers and bed design. The bottom of the trench should be LEVEL. • In fill systems (trench, bed and galley), compact the loose material to eliminate settling. • Prior to installing the chambers, scarify the bottom and sidewalls of the soil surface.

Typical CULTEC Septic System

Front View

Septic Tank

Distribution Box

CULTEC Chambers

Top View

Model Height WidthMin.

Recommended Trench Width

Contactor® Field Drain™ C-4 and C-4HD 8.5” 48” 52”

Contactor® EZ-24 and EZ-24HD 12.5” 16” 20”

Contactor® 100 and 100HD 12.5” 36” 39”

Recharger® 150XLHD 18.0” 33” 36”

Recharger® 180HD 20.5” 36” 40”

Recharger® 280HD 26.5” 47” 52”

Recharger® 330XLHD 30.5” 52” 56”

Recharger® 900HD 48” 78” 82”

CULTEC Septic Chambers

Page 26: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

7

Chamber Installation in a Typical Gravity System • Set the starter unit (Model R) in

the trench. Position the large rib end of the chamber toward the effluent feed pipe to start the line.

• OPTIONAL (See fabric installation if not using a splash deflector):

Place a splash deflector under the feed pipe discharge to prevent rutting of the base soil.

• Continue the line of chambers by joining the units using patented interlocking rib connection. Overlap the larger rib (Model E) over the smaller rib of the preceding chamber. No screws are needed. Continue to the desired length and end the line of chambers using Model E.

Model E

Model R

Hidden End

Model E

Model E

Installation of the Fabric Interface for a Gravelless Septic System

• To determine the length of CULTEC No. 410™ filter fabric, or approved equal, used to cover an installed line of chambers, measure the distance on the top of the Contactor®, Recharger® or Field Drain™ chambers and add the required fabric length from the table on page 8. • After the starting CULTEC chamber is put in place, lay approximately 2 feet of the CULTEC No. 410™ Filter Fabric on the ground at the beginning of the line spanning the width of the chamber. • Throw 5-6 shovels full of approved backfill over the cloth where it meets the base of the end wall to secure it in place. • Pull fabric up the vertical end wall, across the top of the line of chambers, and down the vertical end wall of the end of the line. Pull the fabric tight. Allow an extra foot or so to continue away from the end wall. • Pull the free end of the fabric interface to the end of the line of the chambers making sure the center of the fabric is even with the center of the chambers, allowing the fabric to drape over evenly to the base of the units.

Note: Contact CULTEC or your local health department to determine which chambers are approved for septic use in your area.

Filter Fabric Installation Profile View

Page 27: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

8

Installation of the Fabric Interface for a Gravelless Septic System (continued)

• Approximately 1-2 feet of extra fabric will be evident if the directions for determining fabric length are followed correctly. • After pulling the fabric tightly over the chambers, throw 5-6 shovels full of approved backfill over the cloth where it meets the base of the final end wall. • Inspect the fabric along the entire line of CULTEC chambers. Look for slight bends in the line where some further positioning of the fabric may be necessary. Inspect also for roots that may prevent the fabric from its proper positioning to the base of the chamber. • Push feed pipe 6” into top inlet opening located on endwall at the beginning of the line. By cutting a small X in the fabric where the inlet is located, stretching the fabric, and pushing the pipe through, the use of pipe seals can be eliminated.

CULTEC No. 410Filter Fabric

NOTE: No guarantee of performance of CULTEC Chambers will be honored if CULTEC No. 410™ Filter Fabric or approved equal is not used.

Recommended Width of FabricUse the recommended fabric width for each chamber. Calculate fabric required.LF of Fabric Required: LF of system + 10% for waste = ______ LF fabric

ModelInstalled Chamber Length

Chamber Length

Adjustment

Fabric Roll Width

Length of Fabric to Add

to Line of Chambers

Contactor® Field Drain™ C-4 and C-4HD 8.00’ 0.50’ 7.50’ 5.50’

Contactor® EZ-24 and EZ-24HD 8.00’ 0.50’ 3.00’ 6.00’

Contactor® 100 7.40’ 0.60’ 4.00’ 6.00’

Contactor® 100HD 7.50’ 0.50’ 4.00’ 6.00’

Recharger® 150XLHD 10.25’ 0.75’ 4.00’ 7.50’

Recharger® 180HD 6.33’ 1.00’ 5.00’ 7.50’

Recharger® 280HD 7.00’ 1.00’ 7.50’ 9.00’

Recharger® 330XLHD 7.00’ 1.50’ 7.50’ 9.00’

Recharger® 900HD 7.00’ 2.25’ 12.50’ 12.00’

CULTEC Septic Chambers

Page 28: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

9

Installation of the Filter Fabric for a Septic System with Stone

• Determine the trench or bed area by multiplying the length and width according to the design. Then, add 10% for overlaps and/or waste. • Place filter fabric (small piece) over the end section of the final chamber, covering the pre-drilled hole (if available) • Filter fabric is placed at the interface of the top of the stone and the soil prior to final backfilling.

CULTEC No. 410Filter Fabric or

Approved Equal

Recommended Width of FabricCalculate the area of the trench or bed. SF of Fabric Required: (Bed L x Bed W) + 10% for waste = ______ SF of fabric

ModelInstalled Chamber Length

Chamber Length

Adjustment

Fabric Roll Width

Length of Fabric to Add

to Line of Chambers

Contactor® Field Drain™ C-4 and C-4HD 8.00’ 0.50’ 5.00’ 5.50’

Contactor® EZ-24 and EZ-24HD 8.00’ 0.50’ 3.00’ 6.00’

Contactor® 100 7.40’ 0.60’ 4.00’ 6.00’

Contactor® 100HD 7.50’ 0.50’ 4.00’ 6.00’

Recharger® 150XLHD 10.25’ 0.75’ 4.00’ 7.50’

Recharger® 180HD 6.33’ 1.00’ 4.00’ 7.50’

Recharger® 280HD 7.00’ 1.00’ 7.50’ 9.00’

Recharger® 330XLHD 7.00’ 1.50’ 7.50’ 9.00’

Recharger® 900HD 7.00’ 2.25’ 7.50’ 12.00’

Page 29: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

10

Backfilling the System

• Place backfill material on the sides of the chambers and walk along the sides of the chambers to compact backfill material. • Place backfill material over top of the chambers to recommended height. • When covering the system for final backfill and determination of grade, it is best to use a small track machine or backhoe bucket weighing less than 10,000 lbs. If using a loader or straight blade type machine, keep loose fill in front of the blade to a height of 2’ - 2½’ above the chamber top. • When necessary to track over the system, traverse perpendicular to the line of chambers (only when backfilled to recommended height.) • Proceed to raise fill to final grade.

NOTE:• Material used to backfill the CULTEC Chamber System should be clean, permeable and approved.• Prior to backfilling the chambers, the system must be inspected by the local health department.

NOTE:For non-traffic installations: Residential installations require a minimum of 9” of cover per manufacturer’s recommendation. Cover requirements may vary per state and local code.

Pipe Distribution System (PDS) Installation

Typical CULTEC Gravity Distribution System with Effluent Feed Pipe in Upper Pipe Carrier • CULTEC promotes two types of pipe distribution systems (PDS) using Contactor® and Recharger®

units: Pressure Distribution and Gravity Distribution. • Install the R chamber model towards the manifold system. • Complete the remainder of the chamber lateral using the E model chamber joining the units using the patented interlocking rib connection. • Place distribution pipe along top of the chambers with the perforation holes placed down. • Place Filter Fabric on top of PDS distribution pipe. • Complete backfill with approved soil to determined elevation. • When covering the system for final backfill and determination of grade, it is best to use a small

track machine or backhoe bucket weighing less than 10,000 lbs. If using a loader or straight blade type machine, keep loose fill in front of the blade to a height of 2’ - 2½’ above the chamber top.

• When necessary to track over the system, traverse perpendicular to the line of chambers (only when backfilled to recommended height.) • Proceed to raise fill to final grade.

CULTEC No. 410Filter Fabric

Perforated Pipe

CULTEC Septic Chambers

Page 30: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

11

Pressure Distribution Installation

CULTEC Pressure Distribution Options

• Pressure distribution systems must meet all local and state codes. • Manifold, lateral (pipe) size, hole-size and hole placement are determined by state and local codes. • Place system lateral at invert height as designed by the system designer. • Follow backfill procedures as described in prior sections. • For self-draining, place a hole at 6 o’clock at the beginning of the lateral and at the end of the

lateral. Use CULTEC No. 410 filter fabric as a splash plate. • If pressure distribution pipe is placed inside the chamber unit, place a small splash plate below the self-draining hole, if used.

CULTEC NO. 410 FILTER FABRICOR EQUAL APPROVED BY CULTEC

OPTION A: PIPE IN CRADLE

OPTION B: PIPE AT INVERT

Page 31: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

12

Installation Instructions for Septic System in Traffic Application

NOTE: Contact CULTEC Technical Assistance for more details on paved installations. Not all septic installa-tion methods are approved by all areas and may vary per state and local code. Refer to the local septic code to verify this application type is approved for use in your area.

Cover Requirements for Traffic Installations under Pavement*

Typical Paved Traffic Septic Detail(note: min. 9” stone base and min. 12” stone above required for Recharger 900HD)

ModelMust use Heavy Duty (HD) models

Minimum Allowable Cover

(not including pavement)

Maximum Allowable Cover

(including pavement)

Contactor® Field Drain™ C-4HD 14” 12’

Contactor® EZ-24HD 14” 12’

Contactor® 100HD 14” 12’

Recharger® 150XLHD 14” 12’

Recharger® 280HD 18” 12’

Recharger® 330XLHD 18” 12’

Recharger® 900HD 24” 6’

* For unpaved traffic applications, contact CULTEC, Inc.

TYP.

CHAMBER HEIGHTINVERT

12" CHAMBER WIDTH

6" MIN.

6" MIN.

VARIES

PAVEMENT

CULTECHEAVY DUTY CHAMBER

1-2 INCH WASHEDCRUSHED STONE CULTEC No. 410 FILTER FABRIC

ON TOP AND SIDES OF STONE

95% COMPACTED FILL

VARIESDEPTH PERDESIGN

CULTEC Septic Chambers

*SEE NOTE

*SEE NOTE

Page 32: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

13

Optional Inspection Port

• Please check your state and local code for inspection requirements. • For applications requiring an inspection port, all CULTEC chambers supply a raised center location that can be cut with a reciprocating or properly sized hole saw. • Locate port. Cut through the covering of CULTEC No. 410™ fabric in order to locate the inspection

port in the center of any chamber.

Typical Inspection Port Detail for Non-Traffic Application

Page 33: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

1414

Optional Inspection Port (continued)

Typical Inspection Port Detail for Traffic Applications

CULTEC Septic Chambers

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

Page 34: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

1515

1-Yr. Limited Warranty

CULTEC, Inc. finished products, when properly installed, registered with Cultec, Inc., and operated under normal condi-tions of use, are covered under Cultec Inc.’s Limited Warranty to be free from defects in material and workmanship for a period of one (1) year from the date of manufacture. In order to obtain Cultec’s Limited Warranty, the product war-ranty registration card must be completed and returned to Cultec, Inc., having been postmarked within thirty (30) days of installation. Failure to return the warranty registration card to Cultec, Inc. shall void the Limited Warranty. This Limited Warranty shall be void if the finished product is not installed within forty-five (45) days of the date of purchase from Cultec, Inc. In order to obtain performance under this Limited Warranty, Cultec, Inc. must be provided with written notice of any defect promptly (in no case later than ten (10) business days after initial discovery AND prior to the end of the Limited Warranty period), with such notice sent to 878 Federal Road, PO Box 280, Brookfield, CT 06804-0280. The origi-nal purchase receipt for the product must be included with documentation supporting any claim under the terms of this Limited Warranty. Failure to promptly submit notice of defect, a receipt and completed limited warranty certificate will void the Limited Warranty. Cultec, Inc. shall not be responsible for any freight charges incurred in connection with this Limited Warranty. A fee may be incurred when Cultec, Inc. (in its sole discretion) deems it necessary for a Cultec, Inc. representative to visit a product installation site.

This Limited Warranty extends only to Cultec, Inc. products when the products are installed in ‘single level’, provided that such products do not, in the collective, amount to more than 12,000 cubic feet (339.84 cubic meters) of water volume storage capacity. This Limited Warranty shall be void where products are installed in ‘multi-layer’ or ‘multi-tier’ systems, as well as wherein collective system volume exceeds 12,000 cubic feet (339.84 cubic meters) of water volume storage ca-pacity. Notwithstanding the foregoing, Cultec, Inc., in its sole discretion, may extend certain Limited Warranty terms upon ‘double-layer’ or ‘double-tier’ product installations, as well as ‘single level’ product installations wherein collective system volume exceeds 12,000 cubic feet (339.84 cubic meters) of water volume storage capacity, provided that (i) the buyer has contacted Cultec, Inc. prior to installation and has advised of the proposed installation design; (ii) all product warran-ty registration information has been provided prior to product installation; (iii) a pre-construction/pre-installation meeting has been held with representatives of Cultec, Inc.; and (iv) Cultec, Inc. has provided written confirmation of its intent to honor any Limited Warranty terms with respect to the specific installation. Under no circumstances shall any decision by Cultec, Inc. to honor such terms be relied upon by any party in any subsequent product purchase or installation.

This Limited Warranty does not apply to installation piping and/or other parts not supplied by Cultec, Inc. Cultec, Inc.’s limited warranties also do not extend to any goods or parts which have been damaged prior to installation, subjected to misuse, damaged by lack of maintenance, improper installation, neglect, damaged by accident, or damaged by being crushed by heavy equipment weighing in excess of the rated load carrying capacity of the product. This Limited Warranty also does not apply to shipping or in-transit damage.

THIS LIMITED WARRANTY DOES NOT APPLY TO CULTEC, INC. PRODUCTS THAT HAVE NOT BEEN INSTALLED ACCORDING TO CULTEC WRITTEN INSTALLATION INSTRUCTIONS. ANY PRODUCT DAMAGE OR FAILURE RESULTING FROM IMPROPER OR NEGLIGENT INSTALLATION IS SPECIFICALLY EXCLUDED FROM THIS WARRANTY AND SHALL REMAIN THE BUYER’S RESPONSIBILITY.

THIS WARRANTY IS LIMITED TO THE BUYER AND IS NOT TRANSFERABLE. THIS EXPRESS LIMITED WARRANTY EX-CLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESSED, IMPLIED, OR STATUTORY, BY ANY LITERATURE, DATA, OR PERSON. CULTEC, INC. EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PAR-TICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTIONS SET FORTH IN THIS LIMITED WARRANTY, NOTWITHSTANDING ANY KNOWLEDGE OF CULTEC, INC. REGARDING THE USE OR USES INTENDED TO BE MADE OF GOODS, PROPOSED CHANGES OR ADDITIONS TO GOODS, OR ANY ASSISTANCE OR SUGGESTIONS THAT MAY HAVE BEEN MADE BY CULTEC, INC. PERSONNEL. BUYER IS RESPON-SIBLE FOR DETERMINING THE SUITABILITY OF CULTEC, INC. PRODUCTS FOR BUYER’S USE OR RESALE, OR FOR INCOR-PORATING THEM INTO OBJECTS OR APPLICATIONS WHICH BUYER DESIGNS, ASSEMBLES, CONSTRUCTS OR MANUFAC-TURES.

CULTEC, INC. WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, HOWEVER ARISING, INCLUDING BUT NOT LIMITED TO THOSE FOR USE OF ANY PRODUCTS, LOSS OF TIME, INCONVE-NIENCE, LOST PROFIT, LABOR CHARGES, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES WITH RESPECT TO PERSONS, BUSINESS, OR PROPERTY, WHETHER AS A RESULT OF BREACH OF WARRANTY, NEGLIGENCE OR OTHERWISE. NOTWITHSTANDING ANY OTHER PROVISION OF THIS LIMITED WARRANTY, BUYER’S REMEDY AGAINST CULTEC, INC. FOR GOODS SUPPLIED OR FOR NON-DELIVERED GOODS OR FAILURE TO FURNISH GOODS, WHETHER OR NOT BASED ON NEGLIGENCE, STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY, IS LIMITED SOLELY, AT CULTEC, INC.’S OPTION, TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON-DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS. CULTEC, INC.’S MAXIMUM LIABILITY UNDER THIS EXCLUSIVE REMEDY SHALL NEVER EXCEED THE COST OF THE SUBJECT PRODUCT. CULTEC, INC. RESERVES THE RIGHT, AT ITS SOLE DISCRETION, TO REFUND THE PURCHASE PRICE IN LIEU OF REPAIR OR REPLACEMENT.

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

Page 35: State of Connecticut Septic Allowance - CULTEC, Inc.cultec.com/Asset/cultec-ct-septic-approval-summary... · State of Connecticut Septic Allowance CULTEC Contactor® and Recharger®

For more information, contact CULTEC at (203) 775-4416 or visit www.cultec.com.© CULTEC, Inc., May 2014 CULTEC Septic Installation Guide Book CULG066 05-14

16CULG066 05-14

Chamber of Choice™

CULTEC, Inc.878 Federal Road • P.O. Box 280 • Brookfield, CT 06804 USA

Phone: 203-775-4416 • Toll Free: 1-800-4-CULTEC • Fax: 203-775-1462Web: www.cultec.com • E-mail: [email protected]