STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In...

11
cdvigroup.com 1 STAR1M - Mullion Mifare ® standalone controller and card reader Security to Access www.cdvigroup.com English EN STAR1M Mullion Mifare ® Standalone Controller and Card Reader

Transcript of STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In...

Page 1: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 1

STAR1M - Mullion Mifare® standalone controller and card reader

Security to Accesswww.cdvigroup.com

English EN

STAR1M

Mullion Mifare® Standalone Controller and Card Reader

Page 2: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com2

STAR1M - Mullion Mifare® standalone controller and card reader

1] PRODUCT PRESENTATION - 2-in-1 Mifare Reader : - Standalone Access control system - Wiegand Mifare® reader mode- Resin-coated electronics- Audible and visual feedback- 3 metre cable (10 wire cable - AWG28)- Up to 150 cards (shadow mode)- Up to 300 cards (standard mode)- 1 Relay output (1A 12V dc)- 1 Request to exit input

-25°C à +70°C

STAR1M

IP54

Dimensions (L x W x D): 130 x 41 x 28 mmTechnology: 13.56 MHzProtocol: Mifare® classic, ultralight CInput voltage: 12VdcConsumption: 120mAWiegand 26/30/44-bit (Mifare® reader)

2] REMINDERS AND RECOMMENDATIONSRecommended cable10 wire cable (AWG28)

Recommended power suppliesADC335 and BS60 (in case the reader is powered by neither the controller nor the reader controller [INTBUSW]).The power supply must be designed to be a limited power supply as defined by EN 60950-1.

EnvironmentWhen in a humid area or close to the sea, we recommend applying varnish to the terminals to avoid oxidation.

Installation recommendationsTo protect the device from back EMF, do not forget to install the varistor across the lock terminals (in parallel).

This product is shipped with a varistor.The varistor must be connected directly to the locking system terminals (electric strikes, electromagnet, or lock) operated by the device. If the device functions with several locking systems, each one must be fitted with a varistor. The varistor limits overload produced by the strike coil, known as self-effect or back EMF. If you are using a shearlock, electromagnet or other type of electric lock, we recommend the use of dedicated power supply for the lock.

For optimum lighting, be

careful to not fold the cable

inside the product.

3] MOUNTING KIT

Leaktight seal

TF 3x30 Screws

S5 Plastic anchor

TORX® Screwdriver tip

TORX® 3x8 Screws

Varistor METALR tag

STAR1M 1 2 2 1 1 1 1

R76,7

R35,

4

7

60

30

Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

31, av du Gal Leclerc93691 PANTIN CEDEXF R A N C ETel : 33(0)148910102Fax : 33(0)148912121www.cdvi.com

Plan M1806-VdE

Edition 00

Date 01/10/2009

ECHELLE 1:1

A4V

DES.: A. Broustal

Matière : ... Tolérance gale : 0.1 Etat de surface : Ra 3,2

A0228015Badge PP New

plan coté pour dépôt "dessin&modèle" C.A.: ...

Vol. (mm3) : Poids (g) :

IK09

Frequency band: 13,553 - 13,567 MHzMaximum power emitted: 42 dBμA/m

We, CDVI, declare that the STAR1M complies with the 2014/53/UE European directive. The full UE declaration is avaiblable on our website www.cdvi.com.

INSTALLATION MANUAL EN

Thank you for buying our products and for the trust placed in our company

Page 3: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 3

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

4] OPERATION MODES

Dipswitch Standalone mode (page 13)

Wiegand mode (page 18)

1 OFF ON

2OFF ON OFF ON

Change the Master card

NORMAL operation

Dipswitch 3 option 44-bit

3OFF ON OFF ON

Shadow mode (page 15)

Standard mode (page 16) 26-bit 30-bit

4 Not assigned

The different dipswitch positions are used to switch the STAR1M to a standalone system or to a Mifare® access reader.

5] WIRING DIAGRAM

C56

C58

C61

1

MM10

4

3

2

1 ON

ON

ON

ON

L7

Q6

Q7

Q8

R77

R78

R79

P1

1P3

BZ3

C6

C24

C59

-+

MM1

MM14

CR3

+

-

CR10

CR25

CR26

CR24

MM3

MM15

CR12

CR13

CR15

I1

+

-

+

-

MM16

CR22

P2

-

+

CR19

CR21

CR20

CR28

CR27

CR29

CR11R70R67

R68R64

R69R65

C68

CR30

Wire colors

Wiring tableStandalone mode Wiegand mode

Red 12Vdc 12Vdc

Black 0V 0V

Green / Data 0

White / Data 1

Blue Normally open /

Grey Common /

Purple Normally closed /

Brown Request to exit input Buzzer input

Yellow / Green LED input

Orange / Red LED input

LEDs on start-up:- Green (1s)- Red (1s)- Blue + BEEP (1s)

LEDs during routine operation:- Standby: Blue- When a tag is read: Green or red

To switch operation mode, please reboot the STAR1M.

Page 4: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com4

STAR1M - Mullion Mifare® standalone controller and card reader

6] SETTING READER MODE

1

ON

2

ON

3

ON

ON ON ON

1 2 3

ON

OFF

ON

OFF

Before powering on, select the operating mode (Wiegand Mifare® reader or standalone mode).

1] Wiegand Mifare® reader (DIP1 ON)- green- red- blue + buzzer (starting sequence)

2] Standalone mode (DIP1 OFF) = factory default setting- green- red- blue + buzzer (starting sequence)- yellow/green: waiting for the Master card to be programmed (when powering on for the 1st time)

7] STANDALONE MODE- Mifare® compliant - ISO 14443A (Mifare® classic)- Programming using the Master card directly on the reader- Capacity: 1 Master card + 300 or 150 user cards (according to mode)- 1 door controller: 1 relay output N.O/N.C contact (1A 12Vdc)- 1 request to exit input- Compatible with METAL, PVP (Mifare®) badges, BV cards (ISO Mifare® credit card format) and ERV, ERNV remote transmitters

INSTALLATION MANUAL EN

ON

4

ON

4

Electric strike wiring example (Fail secure)

12V DCADC335

Push button

Strike fail secure

All our locks are fitted with a varistor.

Page 5: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 5

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

Electromagnetic lock wiring example (Fail safe)

12V DCADC335

Push button

MagnetStrike fail safe

Normal operation

1

ON

2

ON

3

ON

4

ON ON

OFF

Swipe user cardAccess granted Beep + green LED + relay activated

Access denied Beep + red LED

Blue LEDPosition DIP2 to ON

The factory setting of the STAR1M is shadow mode.For first use, please program a master badge (see process page 8).

Page 6: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com6

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

Enter programming mode

Yellow led

Present user card Beep + green LED then yellow LED

Blue LEDPresent the master badge

Swipe the master badge or wait 10 seconds

Exit programming mode

To add more cards, repeat step user card and step shadow card.

Present the shadow card2 beeps + green LED flashing

Add user cards (max. 150)

Delete user cards

Enter programming mode

Yellow LED

Present the user card or its shadow cardBeep + LED OFF then back to yellow LEDPresent again the same cardBeep + red LED then back to yellow LEDBoth cards are deleted

Blue LED Present the master badge

Swipe the master badge or wait 10 seconds

Exit programming mode

7.1 Shadow mode

In Shadow mode, two different badges are programmed for the same user. The user gets one of the two badges and the second badge is stored in a secure place by the system supervisor as a shadow badge. These 2 badges can both grant access. In the event that the user badge is lost or stolen, the shadow badge can be used to delete the user badge from the STAR1M.

1

ON

2

ON

3

ON

4

ON ON

OFF

Dipswitch setting

Page 7: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 7

STAR1M - Mullion Mifare® standalone controller and card reader

Blue LED

INSTALLATION MANUAL EN

Add user cards (max. 300)

Enter programming mode

Yellow LED

Present the user card one after the otherBeep + green LED then yellow LED If the card is already programmedBeep + LED OFF then back to yellow LED

Blue LEDPresent the master badge

Swipe the master badge or wait 10 seconds

Exit programming mode

Enter programming mode

Yellow LED

Present the user cardBeep + LED OFF then back to yellow LED Present again the same card Beep + red LED then back to yellow LED.

Blue LED

Delete user cards

Present the master badge

Swipe the master card or wait 10 seconds

Exit programming mode

7.2 Standard mode

In Standard Mode only one user badge is programmed for each user. To delete a user from the STAR1M, enter the programming mode and present the user badge.

1

ON

2

ON

3

ON

4

ON ON

OFF

Dipswitch setting

Page 8: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com8

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

7.3 Common operation

Program or replace a Master badge

1

ON

2

ON

3

ON

4

ON ON

OFF

Set DIP2 to OFF

Yellow LED + Beep

Present the new master badge (the old one will be erased)

Beep + LED OFF

1

ON

2

ON

3

ON

4

ON ON

OFF

Set DIP2 to ON

Beep

Blue LED

After 10 seconds

White and Red LED flashing + Beep

1 flash : 1 second

Program the unlock time

Enter programming mode

Yellow LED

Press the push button Each push button press: 1 second Blue LEDPresent the master badge

Default value : 5 seconds, programmable from 01 to 99 seconds

1

ON

2

ON

3

ON

4

ON ON

OFF

Switch on power supply

White/Red LED flashing while the memory is deleted. Followed by start-up sequence

Delete all cards (reset the reader to the factory default values)

Switch off power supply Set DIP1 to ON

Switch off power supply

1

ON

2

ON

3

ON

4

ON ON

OFF

Set DIP1 and DIP2 to OFF Standalone Mode is activated Switch on power supply

To delete all cards switch to Wiegand mode Switch to standalone mode

Page 9: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 9

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

8.1 Wiegand 26, 30 and 44 bit output format

8] MIFARE® READER WIEGAND MODE

OFF1

ON

2

ON

3

ON

4

ON ON

OFF1

ON

2

ON

3

ON

4

ON ON

OFF1

ON

2

ON

3

ON

4

ON ON

30-bit Wiegand Output

44-bit Wiegand Output

26-bit Wiegand Output

Important : - Switching « shadow mode » to « independent mode »: all cards are saved

but become independant- Switching « independent mode » to « shadow mode »: all cards are erased

Page 10: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com10

STAR1M - Mullion Mifare® standalone controller and card readerINSTALLATION MANUAL EN

8.3 LEDs management in CENTAUR

8.2 LEDs management in ATRIUM

GREEN ACCESS GRANTEDRED ACCESS DENIEDBLUE STANDBY

LED STATUS

GREEN ACCESS GRANTEDRED ACCESS DENIEDBLUE STANDBY

LED STATUS

GREEN LEDCONFIGURATION

RED LEDCONFIGURATION

GREEN LED CONFIGURATION

RED LEDCONFIGURATION

Reference : G0301FR1031V04Extranet : CDVI_IM_STAR1M_A5_EN-01

Page 11: STAR1M...Swipe the master card or wait 10 seconds Exit programming mode 7.2 Standard mode In Standard Mode only one user badge is programmed for each user. To delete a user from the

cdvigroup.com 11

STAR1M - Mullion Mifare® standalone controller and card reader

Security to Accesswww.cdvigroup.com

Reference : G0301FR1031V04Extranet : CDVI_IM_STAR1M_A5_EN-01

*G0301FR1031V04*

CDVI GroupFRANCE (Headquarters)

Phone: +33 (0)1 48 91 01 02

CDVI FRANCE + EXPORT31, av. du Général Leclerc93500 PANTIN - FrancePhone: +33 (0)1 48 91 01 02www.cdvi.com

CDVI AMERICAS[CANADA - USA]Phone: +1 (450) 682 7945www.cdvi.ca

CDVI BENELUX[BELGIUM - NETHERLANDS - LUXEMBOURG]Phone: +32 (0) 56 73 93 00www.cdvibenelux.com

CDVI TAIWANPhone: +886 (0)42471 2188www.cdvichina.cn

CDVI SUISSEPhone: +41 (0)21 882 18 41www.cdvi.ch

CDVI CHINA Phone: +86 (0)10 84606132/82www.cdvichina.cn

CDVI IBÉRICA[SPAIN - PORTUGAL]Phone: +34 (0)935 390 966www.cdviberica.com

CDVI ITALIAPhone: +39 0321 90 573 www.cdvi.it

CDVI MAROCPhone: +212 (0)5 22 48 09 40www.cdvi.ma

CDVI NORDICS [SWEDEN - DENMARK - NORWAY - FINLAND]Phone: +46 (0)31 760 19 30www.cdvi.se CDVI UK [UNITED KINGDOM - IRELAND]Phone: +44 (0)1628 531300 www.cdvi.co.uk

CDVI POLSKAPhone +48 12 659 23 44 www.cdvi.com.pl

All t

he in

form

atio

n co

ntai

ned

with

in t

his

docu

men

t (p

ictu

res,

dra

win

gs,

feat

ures

, sp

ecifi

catio

ns a

nd d

imen

sion

s)co

uld

be p

erce

ptib

ly d

iffer

ent

and

can

be c

hang

ed w

ithou

t pr

ior

notic

e.