    STAR1MCentrale autonome/Lecteur Mifare® 13,56MHzStandalone Access Control System / 13,56 MHz Mifare® reader

  • cdvigroup.com2

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    1] PRÉSENTATION DU PRODUIT

    - Produit 2 en 1 : fonctionnement centrale autonome fonctionnement lecteur Mifare® (13,56 MHz)- Électronique résinée- Signalisation lumineuse et sonore- 3m de câble (10 brins- AWG28)- Disponible en noir- Capacité : 300 badges (autonome)

    Dimensions (L x l x P) : 130 x 41 x 28 mmTechnologie : 13,56 MHzProtocole : Mifare® classicAlimentation : 12 V DCConsommation : 200 mAWiegand 26/30/44 bits (lecteur Mifare®)

    IP54

    -25°C à +70°C

    Certification CE

    DEEE

    Certification FCC CFR 47part 15 compliance

    2] RAPPELS ET RECOMMANDATIONSSTAR1M

    Recommandations d’installationPour sécuriser l’installation, n’oubliez pas de placer la varistance sur le système de verrouillage en parallèle sur les bornes de l’alimentation.

    Câble préconiséCâble 10 conducteurs (AWG28)

    Alimentations préconisées ADC335 et BS60 (lorsque le produit n’est alimenté ni par la centrale, ni par le contrôleur de porte [INTBUSW]).

    EnvironnementSi vous installez ce produit dans un environnement marin/salin, il est préconisé de passer du vernis en bombe

    sur les contacts après câblage afin de pré-venir le risque d’oxydation.

    Ce produit est livré avec une varistance. Celle-ci doit être montée directement sur les bornes de la gâche (ventouse, moteur,…) commandée par l’équipement. Si l’appareil fonctionne avec plusieurs gâches, chacune doit être équipée de varistance. La varistance limite les surtensions provoquées par le bobinage de la gâche – effet de self. Dans le cas où la ventouse utilisée est du type “Shear Lock”, celle-ci doit être alimentée par une alimentation indépendante du STAR1M.

    Joint d’étanchéité

    Vis TF 3x30

    Cheville plastique S5

    Embout tournevis TORX®

    Vis TORX® 3x8 Varistance Badge METAL

    STAR1M 1 2 2 1 1 1 1

    3] ÉLÉMENTS FOURNIS

    Pour un éclairage optimal,

    attention de ne pas plier le câble à

    l’intérieur du produit.

    R76,7

    R35,

    4

    7

    60

    30

    Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

    31, av du Gal Leclerc93691 PANTIN CEDEXF R A N C ETel : 33(0)148910102Fax : 33(0)148912121www.cdvi.com

    Plan M1806-VdE

    Edition 00

    Date 01/10/2009

    ECHELLE 1:1

    A4V

    DES.: A. Broustal

    Matière : ... Tolérance gale : 0.1 Etat de surface : Ra 3,2

    A0228015Badge PP New

    plan coté pour dépôt "dessin&modèle" C.A.: ...

    Vol. (mm3) : Poids (g) :

  • cdvigroup.com 3

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    1 A l’aide du fond, placez les marques pour fixer le produit. Percez le support de montage au niveau des marques (diamètres préconi-sés : Ø5 mm et Ø15 mm). Grâce au schéma de câblage, prévoyez la sortie des câbles cachés dans la surface ou à l’extérieur (moulure).

    4] MONTAGE

    2 Placez le joint au dos du fond en commençant par le bas. (fig. a). Le joint doit dépasser d’environ 2 mm au niveau du sommet de la partie arrière du lecteur (fig. b).

    3 Placez les chevilles dans les trous, passez le câble et raccordez-le (voir schéma de câblage page 4), puis fixez le lecteur avec la vis TORX® grâce à l’outil TORX® (fig. c). N’oubliez pas de placer la varistance au niveau du système de verrouillage (Voir page 2 “Rappels et recommandations”).

    Fig. aFig. b

    Ø 15

    Ø 5

    Fig. c

  • cdvigroup.com4

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    6] SCHÉMA DE CÂBLAGE

    C56

    C58

    C61

    1

    MM10

    4

    3

    2

    1 ON

    ON

    ON

    ON

    L7

    Q6

    Q7

    Q8

    R77

    R78

    R79

    P1

    1P3

    BZ3

    C6

    C24

    C59

    -+

    MM1

    MM14

    CR3

    +

    -

    CR10

    CR25

    CR26

    CR24

    MM3

    MM15

    CR12

    CR13

    CR15

    I1

    +

    -

    +

    -

    MM16

    CR22

    P2

    -

    +

    CR19

    CR21

    CR20

    CR28

    CR27

    CR29

    CR11R70R67

    R68R64

    R69R65

    C68

    CR30

    STAR1MRaccordements

    Centrale autonome Lecteur Mifare®Rouge 12 V DC 12 V DC

    Noir 0 V 0 V

    Vert / Data 0

    Blanc / Data1

    Bleu Contact relais normalement ouvert - NO /

    Gris Commun - C /

    Violet Contact relais normalement connecté - NC /

    Marron Bouton poussoir de sortie Entrée buzzer

    Jaune / Entrée voyant vert

    Orange / Entrée voyant rouge

    5] FONCTIONNEMENT

    Centrale autonome (liste blanche)

    Lecteur Mifare® (WIEGAND)

    1 OFF ON

    2OFF ON OFF ON

    Changer badge Maître

    Fonctionnement NORMAL

    Option du Dipswitch 3 44 bits

    3 Non attribuéOFF ON

    26 bits 30 bits

    4 Non attribué

    Voyants au démarrage : - Vert (1s)- Rouge (1s)- Bleu + BIP (1s)

    Voyants en fonctionnement général :- Repos : Bleu- Passage badge : Vert ou rouge

    Les différentes positions des Dipswitchs permettent de passer le STAR1M en Centrale autonome ou en Lecteur Mifare®.

    Fonctionnement

    Dipswitch

  • cdvigroup.com 5

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    7] PROGRAMMATIONAvant la mise sous tension, sélectionnez le mode de gestion (lecteur Mifare® ou centrale autonome).

    1] Lecteur wiegand Mifare® (DIP1 sur ON)- vert- rouge- bleu + buzzer (séquence de démarrage)

    2] Centrale autonome (DIP1 sur OFF) = réglage usine- vert- rouge- bleu + buzzer (séquence de démarrage)- jaune/vert : attente présentation du badge Maître (lors de la 1ère mise sous tension)

    1

    ON

    2

    ON

    3

    ON

    4

    ON

    ON ON ON ON

    1 2 3 4

    ON

    OFF

    ON

    OFF

    - Conforme Mifare® - ISO 14443A (Mifare® classic).- Programmation via le badge Maître directement sur le lecteur : - Le badge Maître et utilisateurs s’enregistrent directement sur le lecteur- Capacité : 1 badge Maître + 300 badges utilisateurs (liste blanche)- Gestion 1 porte : 1 relais NO/NC- Mode «LISTE BLANCHE» : permettant de fonctionner qu’avec les badges pré-enregistrés.- 1 entrée bouton poussoir - Fonctionne avec les badges METAL, PVP (Mifare®), les cartes BV (ISO Mifare® format carte de crédit) et ERV.

    8] FONCTIONNEMENT DE LA CENTRALE AUTONOME

    V

    V

    BP

    V

    ADC335

    Exemple de raccordement du fonctionnement centrale autonome12 VDC(-10%/+20%)

  • cdvigroup.com6

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    1

    ON

    2

    ON

    3

    ON

    4

    ON

    Fonctionnement normal : - Basculer DIP2 en ON après enregistrement du badge MaîtreBadge reconnu : - Voyant vert + BIP + activation relais pendant toute la durée de temporisation d’ouverture porteBadge non reconnu :- Voyant rouge + BIP

    Créer ou remplacer un badge Maître- Basculer DIP2 en OFF - BIP + voyant jaune jusqu’à la présentation d’un badge- Présenter le badge Maître voulu devant le lecteur- BIP puis le voyant s’éteint Plus aucun badge n’est pris en compte- Basculer le DIP2 en ON pour quitter le mode

    Créer/ajouter des badges utilisateurs (max. 300) ?- Présenter le badge Maître, le lecteur passe en programmation (voyant jaune + BIP)- Présenter chaque badges utilisateurs un à un; 10s après le dernier badge présenté = sortie du mode programmation- Présentation badge : si badge non enregistré, voyant vert + BIP puis retour voyant jaune si badge déjà enregistré, voyant éteint + BIP puis retour voyant jaune. - Chaque présentation de badge remet la temporisation à 0- Sortie du mode de programmation : BIP puis retour au voyant bleu

    Effacer des badges utilisateurs - Présenter le badge Maître, le lecteur passe en programmation (le voyant jaune + BIP)- Lancement d’une temporisation de 10s avant la sortie du mode de programmation- Présenter consécutivement deux fois le même badge pour le supprimer- Présentation d’un badge déjà enregistré : voyant éteint + BIP puis retour voyant jaune- Présenter une deuxième fois le même badge pour le supprimer : voyant rouge + bip puis retour au voyant jaune- Attention si le badge est inconnu, cela va enregistrer le badge - Chaque présentation badge remet la temporisation à 0- Sortie du mode de programmation : BIP puis retour au voyant bleu

    ON

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    Raccordement de la commande d’ouverture : La commande d’ouverture est maintenue pendant 5 secondes par défaut.La temporisation de porte est modifiable de 2 à 20 secondes.

  • cdvigroup.com 7

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    Suppression de tous les badges (rétablissement de la configuration par défaut)- Couper l’alimentation du STAR1M / Basculer le DIP1 sur ON- Rétablir l’alimentation du STAR1M. (Passage en mode lecteur Mifare®)- La voyant blanc/rouge s’active pendant l’effacement de la mémoire.- L’effacement de la mémoire est suivi de la séquence de démarrage (vert, rouge, bleu + BIP)- Attendre la fin de la séquence de démarrage puis couper l’alimentation du STAR1M.- Basculer le DIP1 et DIP2 sur OFF (mode centrale autonome activé)

    Programmation du temps d’ouverture du relais de serrure- Présenter le badge Maître, voyant jaune + BIP (mode programmation)- Lancement d’une temporisation de 10s avant la sortie du mode de programmation- Appuyer sur le bouton poussoir. Chaque pression du BP = 1 seconde. Exemple : pour 10 sec, faire 10 pressions du BP, maxi 20 secondes- Sortie du mode programmation au bout de 10s d’inactivité- Clignotement voyants blanc et rouge équivalent aux nombres de seconde configurée + BIP- Sortie du mode de programmation :BIP puis retour au voyant bleu.

    1ON 2ON 3ON 4ON ONOFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    9.1 Format de sortie WIEGAND 26, 30 et 44 bitsFormat Wiegand 26 bits

    Format 26 bits hexadécimal. La communication s’effectue par une liaison de type Wiegand 26 bits (signaux : DATA1, DATA0). La trame est constituée d’une totalité de 26 bits et se décompose ainsi :

    1. 1ère parité : 1 bit - parité de 12 premiers bits.Code de badge : 3 mots d’un octet représentant des 6 derniers termesChaque mot est transmis bit de poids fort en premier.

    2. 2ème parité : 1 bit - parité impaire des 12 derniers bits

    Le code émis est 166A37 en hexadécimal

    Parité 1 :

    Parité 2 :

    Bit 1 Bit 2 à bit 25 Bit 26

    Parité paire sur bit 2 à bit 13 Donnée (24 bits) Parité impaire sur bit 14 à bit 25

    Exemple : pour un badge dont le code hexadécimal est 00166A37

    1 0001 0110 0110 1010 0011 0111 0

    Parité 1 1 6 6 A 3 7 Parité 2

    0 si le nombre de 1 dans le bit 14 à bit 25 est impair, 1 si le nombre de 1 dans le bit 14 à bit 25 est pair.

    0 si le nombre de 1 dans le bit 2 à 13 est pair,1 si le nombre de 1 dans le bit 2 à 13 est impair,

    ON

    9] FONCTIONNEMENT LECTEUR MIFARE®

  • cdvigroup.com8

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    Format Wiegand 30 bits

    Format 30 bits hexadécimal. La communication s’effectue par une liaison de type Wiegand 30 bits (signaux : DATA1, DATA0). La trame est constituée d’une totalité de 30 bits et se décompose ainsi :

    1. 1ère parité : 1 bit - parité de 14 premiers bits.Code de badge : 7 quartets représentant le code du badgeChaque mot est transmis bit de poids fort en premier.

    2. 2ème parité : 1 bit - parité impaire des 12 derniers bits

    Bit 1 Bit 2 à bit 29 Bit 30

    Parité paire sur bit 2 à bit 15 Donnée (28 bits) Parité impaire sur bit 16 à bit 29

    Exemple : pour un badge dont le code hexadécimal est 00166A37

    0 0000 0001 0110 0110 1010 0011 0111 1

    Parité 1 0 1 6 6 A 3 7 Parité 2

    Le code émis est 0166A37 en hexadécimal

    Parité 1 :

    Parité 2 :

    Format Wiegand 44 bits

    Format 44 bits hexadécimal. La communication s’effectue par une liaison de type Wiegand 44 bits (signaux : DATA1, DATA0). La trame est constituée d’une totalité de 44 bits et se décompose ainsi :

    Données : 10 chiffres hexadécimaux (octet de poids fort en premier), Chaque chiffre hexadécimal = 4 bits (bits de poids fort en premier)LRC : 4 bits = OU exclusif entre les chiffres de la donnée (bit de poids fort en premier)

    Bit 1 à bit 40 Bit 41 à bit 44

    Code du badge LRC

    Exemple : pour un badge dont le code hexadécimal est 001950C3

    0000 0000 0000 0000 0001 1001 0101 0000 1100 0011 0010

    0 0 0 0 1 9 5 0 C 3 2

    LRC

    0 si le nombre de 1 dans le bit 16 à bit 29 est impair, 1 si le nombre de 1 dans le bit 16 à bit 29 est pair.

    0 si le nombre de 1 dans le bit 2 à 15 est pair,1 si le nombre de 1 dans le bit 2 à 15 est impair,

    Le code émis est 00001950C3 en hexadécimal

  • cdvigroup.com 9

    MANUEL D’INSTALLATION FRSTAR1M - Centrale autonome / Lecteur Mifare®

    PARAMÉTRAGEVOYANT VERT

    PARAMÉTRAGEVOYANT ROUGE

    VERT ACCÈS AUTORISÉROUGE ACCÈS REFUSÉBLEU EN ATTENTE

    ÉTATVOYANTS

    9.3 Paramétrage des voyants sur le système CENTAUR

    9.2 Paramétrage des voyants sur le système ATRIUM

    PARAMÉTRAGEVOYANT VERT

    PARAMÉTRAGEVOYANT ROUGE

    VERT ACCÈS AUTORISÉROUGE ACCÈS REFUSÉBLEU EN ATTENTE

    ÉTATVOYANTS

  • cdvigroup.com10

    1] PRODUCT PRESENTATION - 2-in-1 product: - standalone Access control system operation - Mifare® reader (13.56 MHz) operation- Resin-coated electronics- Audible and visual feedback- 3m of cable (10 leads - AWG28)- Available version black- Up to 300 cards (standalone)

    IP54

    -25°C à +70°C

    Certification CE

    DEEE

    FCC Certification CFR 47 part 15 compliance

    STAR1M

    Dimensions (L x W x D): 130 x 41 x 28 mmTechnology: 13.56 MHzProtocol: Mifare® classicPower supply: 12 V dcConsumption: 200 mAWiegand 26/30/44 bits (reader Mifare®)

    2] REMINDERS AND RECOMMENDATIONS

    Installation recommendationsTo protect the device from back-emf, do not forget to install the varistor across the lock terminals, in parallel.

    Recommended cable10-lead cable (AWG28)

    Recommended power suppliesADC335 and BS60 (in case the reader is powered neither by the controller nor by the reader controller [INTBUSW]).

    EnvironmentWhen in a humid area or close to the sea, we recommend applying varnish to the terminals to avoid oxidation.

    This product is shipped with a varistor.The varistor must be connected directly to the locking system terminals (electric strikes, electromagnet, or lock) operated by the device. If the device functions with several locking systems, each one must be fitted with a varistor. The varis-tor limits overload produced by the strike coil, known as self-effect or back-emf. If you are using a “Shear Lock”, electro-magnet or other type of electric lock, we recommend the use of dedicated power supply for the lock.

    For optimum lighting, be

    careful to not fold the cable

    inside the product.

    3] MOUNTING KIT

    Leaktight seal

    TF 3x30 Screws

    S5 Plastic anchor

    TORX® Screwdriver tip

    TORX® 3x8 Screws

    Varistor METAL card

    STAR1M 1 2 2 1 1 1 1

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    R76,7

    R35,

    4

    7

    60

    30

    Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

    31, av du Gal Leclerc93691 PANTIN CEDEXF R A N C ETel : 33(0)148910102Fax : 33(0)148912121www.cdvi.com

    Plan M1806-VdE

    Edition 00

    Date 01/10/2009

    ECHELLE 1:1

    A4V

    DES.: A. Broustal

    Matière : ... Tolérance gale : 0.1 Etat de surface : Ra 3,2

    A0228015Badge PP New

    plan coté pour dépôt "dessin&modèle" C.A.: ...

    Vol. (mm3) : Poids (g) :

  • cdvigroup.com 11

    4] MOUNTING

    Fig. aFig. b

    Ø 15

    Ø 5

    Fig. c

    3

    1 2 Trace the markings to fix the product using the back casing. Drill the fixing support using the markings (recommended diameters: Ø5 mm and Ø15 mm). Using the wiring diagram, plan for the cable exits hidden under the sur-face or outside (trunking).

    Fit the seal on the back plate starting from the bottom. (fig. a). The seal must overlap the back part of the reader by about 2 mm (fig. b).

    Fit the anchors in the holes, pass the cable and connect it (see wiring diagram on page 14), then fix the reader using the TORX® screw using the TORX® tool (fig. c). Remember to fit the varistor at the locking system level (see “Reminders and recommendations” on page 12).

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

  • cdvigroup.com12

    5] OPERATION

    Standalone system (white list)

    Mifare® reader (WIEGAND)

    1 OFF ON

    2OFF ON OFF ON

    Change the Master card

    NORMAL operation

    Dipswitch 3 option 44 bits

    3 Not assignedOFF ON

    26 bits 30 bits

    4 Not assigned

    Operation

    Dipswitch

    The different dipswitch positions are used to switch the STAR1M to a standalone system or to a Mifare® reader.

    6] WIRING DIAGRAM

    C56

    C58

    C61

    1

    MM10

    4

    3

    2

    1 ON

    ON

    ON

    ON

    L7

    Q6

    Q7

    Q8

    R77

    R78

    R79

    P1

    1P3

    BZ3

    C6

    C24

    C59

    -+

    MM1

    MM14

    CR3

    +

    -

    CR10

    CR25

    CR26

    CR24

    MM3

    MM15

    CR12

    CR13

    CR15

    I1

    +

    -

    +

    -

    MM16

    CR22

    P2

    -

    +

    CR19

    CR21

    CR20

    CR28

    CR27

    CR29

    CR11R70R67

    R68R64

    R69R65

    C68

    CR30

    STAR1MConnetions

    Standalone system Mifare® readerRed 12 V dc 12 V dc

    Black 0 V 0 V

    Green / Data 0

    White / Data1

    Blue Normally open relay contact - NO /

    Grey Common - C /

    Purple Normally connected relay contact - NC /

    Brown Exit push button Buzzer input

    Yellow / Green LED input

    Orange / Orange LED input

    LEDs on start-up:- Green (1s)- Red (1s)- Blue + BEEP (1s)

    LEDs during routine operation:- Standby: Blue- When a badge is read: Green or red

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

  • cdvigroup.com 13

    7] PROGRAMMING

    1

    ON

    2

    ON

    3

    ON

    ON ON ON

    1 2 3

    ON

    OFF

    ON

    OFF

    Before powering on, select the management mode (Mifare® reader or standalone system).

    1] Mifare® wiegand reader (DIP1 ON)- green- red- blue + buzzer (starting sequence)

    2] Standalone system (DIP1 OFF) = factory setting- green- red- blue + buzzer (starting sequence)- yellow/green: waiting for the Master card to be read (when powering on for the 1st time)

    8] STANDALONE SYSTEM OPERATION- Mifare® compliant - ISO 14443A (Mifare® classic).- Programming using the Master card directly on the reader:- The Master and user cards are registered directly on the reader- Capacity: 1 Master card + 300 user cards (white list)- Management of 1 door controller : 1 relay NO/NC - “WHITE LIST” mode: can only be operated using pre-registered cards- 1 push button entry- Operates with METAL, PVP (Mifare®) badges, BV cards (ISO Mifare® credit card format) and ERV cards.

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    ON

    4

    ON

    4

    V

    V

    BP

    V

    ADC335 12 VDC(-10%/+20%)

    Example of a standalone system operation connection

  • cdvigroup.com14

    Normal operation:- Position DIP2 to ON after registering the Master cardCard recognised:- Green LED + BEEP + relay activated for the door open timer durationCard not recognised:- Red LED + BEEP

    To create or replace a Master card- Position DIP2 to OFF- BEEP + yellow LED until a card is passed- Place the Master card in question in front of the reader- One BEEP and the LED turns off. No other cards are taken into account- Position DIP2 to ON to exit this mode

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    To create/add user cards (max. 300)- Present the Master card in front of the reader, the reader switches to programming mode (yellow LED + BEEP)- Pass the user cards in front of the reader one after the other; 10 seconds after the last card is registered, programming mode is exited.- Presenting cards if the card is not registered, green LED + BEEP then return to yellow LED if the card was already registered, LED off + BEEP then return to yellow LED.- Each time a card is presented, the timer is reset to 0- Exit from programming mode: BEEP and return to the blue LED

    To erase user cards- Present the Master card in front of the reader, the reader switches to programming mode (the reader’s yellow LED turns on, followed by a BEEP)- A 10s timer is triggered until programming mode is exited- Pass the same card in front of the reader twice in a row to delete it- If the card was already registered: LED off + BEEP then return to yellow LED- Pass the same card in front of the reader again to delete it: red LED + BEEP then return to yellow LED- Caution, if the card is unknown it will register it- Each time a card is presented, the timer is reset to 0- Exit from programming mode: BEEP and return to the blue LED

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    Open control connection:By default, the open control is maintained for 5 seconds.The door timer can be set from 2 to 20 seconds.

    Programming the lock relay open time- Present the Master card in front of the reader, the reader switches to programming mode (the yellow LED turns on, followed by a BEEP)- A 10s timer is triggered until programming mode is exited- Press the push button. Each time the PB is pressed = 1 second. For example: for 10 secs., press the PB 10 times. Max. 20 seconds

  • cdvigroup.com 15

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    1

    ON

    2

    ON

    3

    ON

    4

    ON ON

    OFF

    - Programming mode is exited after 10 seconds without any actions- The white and red LED flash the number of times that correspond to the configured number of seconds, followed by a BEEP- Exit from programming mode: BEEP and return to the blue LED.

    Deleting all cards (return to the default configuration)- Cut the STAR1M power supply / Position DIP1 to ON- Turn the STAR1M power supply back on. (Switch to Mifare® reader mode)- The white/red LED is activated while the memory is deleted.- The deletion of the memory is followed by the start-up sequence (green, red, blue + BEEP)- Wait for the start sequence to end and then cut the STARM1 power supply.- Position DIP1 and DIP2 to OFF (switch to standalone system mode)- The device waits for a new Master card to be placed in front of the reader- Turn the power supply back on, the STARM1 is ready for reprogramming.

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    9] MIFARE® READER OPERATION9.1 WIEGAND 26, 30 and 44 bit output format

    26-bit Wiegand Output

    Hexadecimal 26 bit format. Communication uses a Wiegand 26 bit type signal (signals: DATA1, DATA0). The frame is composed of a total of 26 bits split up as follows:

    1. First parity: 1 bit - parity for the first 12 bits.Badge code: 3 one byte words representing the 6 last termsEach word is sent with the most significant bit first.

    2. Second parity: 1 bit - odd parity for the last 12 bits

    Bit 1 Bit 2 à bit 25 Bit 26

    Even parity on bit 2 to bit 13 Data (24 bits) Odd parity on bit 14 to bit 25

    For example: for a card with hexadecimal code 00166A37

    1 0001 0110 0110 1010 0011 0111 0

    Parity 1 1 6 6 A 3 7 Parity 2

    The transmitted hexadecimal code is 166A37

    Parity 1:

    Parity 2:

    0 if the number of ‘1’s in bits 2 to 13 is even, 1 if the number of ‘1’s from bit 2 to 13 is odd.

    0 if the number of ‘1’s in bits 14 to 25 is odd, 1 if the number of ‘1’s from bit 14 to 25 is even.

  • cdvigroup.com16

    30-bit Wiegand Output

    Hexadecimal 30 bit format. Communication uses a Wiegand 30 bit type signal (signals: DATA1, DATA0). The frame is composed of a total of 30 bits split up as follows:

    1. First parity: 1 bit - parity for the first 14 bits.Badge code: 7 half byte representing the card codeEach word is sent with the most significant bit first.

    2. Second parity: 1 bit - odd parity for the last 12 bits

    Bit 1 Bit 2 à bit 29 Bit 30

    Even parity on bit 2 to bit 15 Data (28 bits) Odd parity on bit 16 to bit 29

    For example: for a card with hexadecimal code 00166A37

    0 0000 0001 0110 0110 1010 0011 0111 1

    Parity 1 0 1 6 6 A 3 7 Parity 2

    The transmitted hexadecimal code is 0166A37

    Parity 1:

    Parity 2:

    0 if the number of ‘1’s in bits 2 to 15 is even, 1 if the number of ‘1’s from bit 2 to 15 is odd.

    0 if the number of ‘1’s in bits 16 to 29 is odd, 1 if the number of ‘1’s from bit 16 to 29 is even.

    44-bit Wiegand format Output

    Hexadecimal 44 bit format. Communication uses a Wiegand 44 bit type signal (si-gnals: DATA1, DATA0). The frame is composed of a total of 44 bits split up as follows:

    Data: 10 hexadecimal digits (most significant byte first). Each hexadecimal digit = 4 bits (most significant bit first)LRC: 4 bits = OR restricted in between the digit of the date, MSBit first

    Bit 1 à bit 40 Bit 41 à bit 44

    Badge code LRC

    For example: for a card with hexadecimal code 001950C3

    0000 0000 0000 0000 0001 1001 0101 0000 1100 0011 0010

    0 0 0 0 1 9 5 0 C 3 2

    LRC

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    The transmitted hexadecimal code is 00001950C3

  • cdvigroup.com 17

    9.3 LEDs management on the CENTAUR system

    9.2 LEDs management on the ATRIUM system

    GREEN ACCESS AUTHORISEDRED ACCESS DENIEDBLUE STANDBY

    LED STATUS

    GREEN ACCESS AUTHORISEDRED ACCESS DENIEDBLUE STANDBY

    LED STATUS

    GREEN LEDCONFIGURATION

    RED LEDCONFIGURATION

    GREEN LED CONFIGURATION

    RED LEDCONFIGURATION

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

  • cdvigroup.com18

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

    NOTES

  • cdvigroup.com 19

    INSTALLATION MANUAL ENSTAR1M - Standalone Access control system / 13,56 MHz Mifare®reader

  • cdvigroup.com20

    Reference : G0301FR1031V02Extranet : CDVI_IM STAR1M CMYK A5 FR-EN-02

    Tout

    es le

    s in

    form

    atio

    ns m

    entio

    nnée

    s à

    titre

    indi

    catif

    sur

    le p

    rése

    nt d

    ocum

    ent

    (pho

    tos,

    des

    sins

    , ca

    ract

    éris

    tique

    ste

    chni

    ques

    et

    dim

    ensi

    ons)

    peu

    vent

    var

    ier

    et s

    ont

    susc

    eptib

    les

    de m

    odifi

    catio

    ns s

    ans

    notifi

    catio

    n pr

    éala

    ble.

    *G0301FR1031V02*

    CDVI GroupFRANCE (Siège social/Headquarter)

    Phone: +33 (0)1 48 91 01 02

    CDVI FRANCE + EXPORT31, av. du Général Leclerc93500 PANTIN - FrancePhone: +33 (0)1 48 91 01 02www.cdvi.com

    CDVI AMERICAS[CANADA - USA]Phone: +1 (450) 682 7945www.cdvi.ca

    CDVI BENELUX[BELGIUM - NETHERLAND - LUXEMBOURG]Phone: +32 (0) 56 73 93 00www.cdvibenelux.com

    CDVI TAIWANPhone: +886 (0)42471 2188www.cdvichina.cn

    CDVI SUISSEPhone: +41 (0)21 882 18 41www.cdvi.ch

    CDVI CHINA Phone: +86 (0)10 84606132/82www.cdvichina.cn

    CDVI IBÉRICA[SPAIN - PORTUGAL]Phone: +34 (0)935 390 966www.cdviberica.com

    CDVI ITALIAPhone: +39 0321 90 573 Fax: +39 0321 90 8018www.cdvi.it

    CDVI MAROCPhone: +212 (0)5 22 48 09 40www.cdvi.ma

    CDVI SWEDEN [SWEDEN - DENMARK - NORWAY - FINLAND]Phone: +46 (0)31 760 19 30www.cdvi.se CDVI UK [UNITED KINGDOM - IRELAND]Phone: +44 (0)1628 531300 www.cdvi.co.uk

    Le choix de l’installateur cdvigroup.com

    All t

    he in

    form

    atio

    n co

    ntai

    ned

    with

    in t

    his

    docu

    men

    t (p

    ictu

    res,

    dra

    win

    g, f

    eatu

    res,

    spe

    cific

    atio

    ns a

    nd d

    imen

    sion

    s)co

    uld

    be p

    erce

    ptib

    ly d

    iffer

    ent

    and

    can

    be c

    hang

    ed w

    ithou

    t pr

    ior

    notic

    e.