STAND TEST 3MeV AB-PO-PH mars 2007Jean-Pierre ROYER POWER CONVERTERS AB-PO-PH ( Pulsed and High...
-
Upload
zachery-jowers -
Category
Documents
-
view
217 -
download
3
Transcript of STAND TEST 3MeV AB-PO-PH mars 2007Jean-Pierre ROYER POWER CONVERTERS AB-PO-PH ( Pulsed and High...
STAND TEST 3MeVSTAND TEST 3MeV
AB-PO-PH mars 2007 Jean-Pierre ROYER
POWER CONVERTERSPOWER CONVERTERS
AB-PO-PH ( Pulsed and High voltage converters)AB-PO-PH ( Pulsed and High voltage converters)
WHERE ARE WE ?WHERE ARE WE ?
AB-PO-PH – mars 2007 J.P. Royer AB-PO-PH
SOURCE H-• 1 High Voltage Converter (40kV, 15 mA, dc)• 1 High Voltage Converter (65kV, 4 mA, dc) • PLCs for converters 40 and 65 kV• 1 Screen bias Converter 2 kV, 1A, dc• 1 Grid bias Converter 500V, 500mA dc• 1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA)
LEBT (SOURCE H-)• 2 pulsed solenoids converters (1200A, 800 microsec. , 2 Hz)• 4 « LPSS » for steerer (70V, 10A bipolar, dc)• 1 « LPS2 » for bending (50A, 35V, dc)
CHOPPER LINE• 11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)• 2 « LPSS » for steerer (35V, 20A, dc)
KLYSTRON MODULATEUR• Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz)• Indian collaboration (100kV, 20A, 800 microsec, 2Hz)
Power converters summary
STAND TEST 3MeVSTAND TEST 3MeV
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
SOURCE H-1 High Voltage Converter (40kV, 10 mA, dc)1 High Voltage Converter (65kV, 2 mA, dc)
Technical Specification For DC High Voltage Power Converters Rated - 40 kV, 10 mA- 65 kV, 2 mAAB-POEDMS No.: 799586 DO FUG, HEINZINGER, TECHNIX
order: TECHNIX 22 kFS ( 40kV 15mA + 65 kV 4 mA) delivery time ~ April 2007
PLC’s for converters 40 and 65 kV
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
SOURCE H-1 Screen bias Converter 2 kV, 1A, dc
order FUG 6384 Euros (similar LEIR) may 20071 Grid bias Converter 500V, 200mA dc
order FUG 3258 Euros (similar LEIR) may 2007
1 Anode bias Converter (5 kV to 20 kV, 20A pulsed 2msec, I dc 20 mA) order capacitor 46 microf. 26 kV: delivery 11-6-2007 specification for “capacitors charging power converter” done
and sent for DO (demand offer)FUG, Heinzinger, Technix: answer foreseen end of march,then order and manufacturing, cabling the cabinet at CERN with
the different elements.
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
LEBT (SOURCE H-)2 pulsed solenoid converters (1200A, 800 microsec. , 2 Hz)
STAND TEST 3MeVSTAND TEST 3MeV
ACTIVE FILTER
CHARGING CIRCUIT
MAINS MATCHINGTRANSFORMER
SEPTUM
L
R
HIGH VOLTAGE
LEIR RING
F.A. CMD
I septum
2 power converters modified (ex septa EPA-PS) :-No matching transformer-Third harmonic to be modified and adjusted-Active filter must work for 800 microseconds-Modifications and adjustments on regulation loops and electronics.
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
CHOPPER LINE11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)
Market survey and call for tender for consolidation Linac 2 and Stand Test 3 MeV :
Contract placed at OCEM. Delivery of 11 units foreseen for end May 2007
12 kFS / power converter (power and electronics)
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
CHOPPER LINE11 « maxidiscap » for quad (300A, flat top 800microsec, 2 Hz)
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
Example of current and voltage waveforms delivered by a maxidiscap on a LEIR magnet
The flat top will be increase until 800 microsec.
voltage
current
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
Maxidiscap E1 to E4
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
LEBT (SOURCE H-)4 « LPSS » for steerer (10A bipolar, dc)1 « LPS2 » for bending (50A, 35V, dc)
CHOPPER LINE2 « LPSS » for steerer (20A, dc)
Power part: Delta power converters ordered and at CERN
Electronic crates and different electronics cards are in progress for manufacturing.
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
LPSS LPS2 E5 to E6
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
KLYSTRON MODULATOR
1-Indian collaboration (100kV, 20A, 800 microsec, 2Hz)
2-Prototype AB-PO (100kV, 20A, 800 microsec, 2Hz)
It was foreseen to start the stand test 3MeV with the Indian modulator but now, due to the delay, the PO prototype will be installed for operation.
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
PULSETRANSFORMER
(OIL TANK)
Main solid stateswitches
A1
C
KF
1:10
Ca
pa
cit
or
ba
nk
ch
arg
er
po
wer
co
nv
ert
er,
PS
1
Anode powerconverter, PS3
A - Anode;C - Collector;K - Cathode;F - Filament
Filament powerconverter, PS4
Vout
Droop compensation powerconverter or “bouncer”, PS2
0.1mF
Capacitordischarge
system
VPS1
VPS2
12 kV max
-120
kV
ma
x
KLYSTRON(OIL TANK)
DC
Hign FrequencyISOLATION
TRANSFORMER
DC
K1
PS1, PS3, PS4 - CommercialPS2 - CERN made
120 kV High voltage cables
120 kV High voltage connectors
DIODERECTIFIER
A
DRIVER DRIVER
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
MODULATOR PROTOTYPE
-The most important parts have been ordered ( ex: capacitors, high voltage pulse transformer, power converters for charging capacitors and for filament heater, H.V. switch, etc…).- Mechanical assembling has begun.- Preliminary tests of components in lab are in progress.
Planning: first tests with klystron foreseen 15-9-2007
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
Pulsed power converter for Klystron
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
Power converters AB-PO
AB-PO-PH mars 2007 J.P. Royer AB-PO-PH
STAND TEST 3MeVSTAND TEST 3MeV
CONCLUSION for the different power converters:
-Team PO/PH responsibility for 27 power converters ( High Voltage, pulsed or DC)-The planning is well followed to respect the general planning STAND TEST 3MeV.
-Effort will be necessary to integrate, to test and to commissioning equipments-Permanent effort (mechanical design, manufacturing) for the high voltage pulsed power converter for klystron modulator.
-Sometimes conflicts with other business: work for shut down, hardware test for start–up accelerators etc…
So we continue to go ahead ……..