Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering...

59
SYSTEM PRESSURE CLASS: Stainless Steel Corrosive Fume Exhaust Systems With PermaShield Fluoropolymer Barrier Coating ROUND DUCT ORDER COVER SHEET Catalog 10/12.6 PermaShield Pipe SHIP TO: COMPANY: STREET / ROAD: MAILING ADDRESS: CITY / STATE CITY / STATE / ZIP CODE: DETAILER: PROJECT MGR.: REF LAYOUT DRAWING: PHONE NO.: JOB NAME: FAX NO.: FOR FAB-TECH ENGINEERING USE: DATE: ORDER DATE: CUT CODE: DELIVERY DATE: ORDER NO.: JOB NAME: JOB PHONE NO.: JOB FAX NO.: OTHER: © COPYRIGHT MARCH 2014 FAB-TECH INC. REV: 01/19/17 RND001AN -18" wg -16" wg -14" wg -12" wg -10" wg -8" wg -6" wg

Transcript of Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering...

Page 1: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

SYSTEM PRESSURE CLASS:

Stainless Steel Corrosive FumeExhaust Systems WithPermaShield FluoropolymerBarrier Coating

ROUND DUCTORDER COVER SHEET

Catalog 10/12.6

PermaShield Pipe

SHIP TO:

COMPANY:

STREET / ROAD:

MAILING ADDRESS:

CITY / STATE

CITY / STATE / ZIP CODE:

DETAILER:

PROJECT MGR.:

REF LAYOUT DRAWING:

PHONE NO.:

JOB NAME:

FAX NO.:

FOR FAB-TECH ENGINEERING USE:

DATE:

ORDER DATE:

CUT CODE:

DELIVERY DATE:

ORDER NO.:

JOB NAME: JOB PHONE NO.: JOB FAX NO.:

OTHER:

© COPYRIGHT MARCH 2014 FAB-TECH INC. REV: 01/19/17 RND001AN

-18" wg-16" wg-14" wg-12" wg-10" wg-8" wg-6" wg

Page 2: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

23

Straight Duct

Straight Duct with Test Port / Drain

Straight Duct with Straight Tap

Straight Duct with Conical Tap

Straight Duct with Lateral Tap

Straight Duct with Multiple Taps Spec Sheet

Straight Duct with Multiple Taps

Gored Elbows

Reducers

Offsets

Concentric Round to Rectangular Transition

PSP-EZ™ Clamp Kit

Cast Ring

Field Installed Nipple

Manual and Hydraulic Swage Kits

Field Installed Test Port

Field Installed Straight Saddle Tap

Field Installed Boot Saddle Tap

PTFE Gaskets

EZ Straight Standard and Custom Length

EZ Tees, Laterals

EZ Elbows

EZ Reducers

FT Flange to KF Flange Adapter

FT Flange to Dwyer Pitot Adapter

FT Flange to Sprinkler Adapter

FT Flange to Swagelok® Adapter

FT Flange to NPT Male Adapter

NPT Female Uncoated Adapter

Field Installed 2" FT Flange

Field Installed FT Flange Saddle Tap

Specialized Installation Tools

3

4

5

6

8

9

10

11

12

13

15

38

39

40

41

44

45

46

47

49

50

51

52

55

55

55

55

56

56

57

58

59

Straight Duct with Shoe Tap 7

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND002AM

48

Angle Ring

EZ Damper, Blastgate, Field Flange, End Cap 53

EZ Clamps & Gaskets 54

6" - 14" AMCA Industrial Isolation Damper

16" - 34" Heavy Duty Industrial Damper

36" - 48" Heavy Duty Industrial Damper

50" & Larger Heavy Duty Industrial Damper

18" - 72" Vortex Damper

4" - 36" Horizontal Run Isolation Blastgate

38" & Larger Horizontal Run Multi-blade

4" - 36" Vertical Run Isolation Blastgate

38" & Larger Vertical Run Multi-blade

24

26

28

FAB-TECH FLANGE SYSTEM

EZ FITTINGS

DUCT & FITTINGS

CONTROL DEVICES

4" - 12" Wafer Isolation Damper 18

ACCESSORIES

2" & 3" EZ Damper & EZ Blastgate 19

Custom Fitting 16

Damper Actuator Worksheet 17

16" - 34" AMCA Heavy Duty Industrial Damper

2736" - 48" AMCA Heavy Duty Industrial Damper

29

34

4" - 14" Industrial Damper (Balance & Isolation) 20

22

30

End Caps 14

ROUND DUCT ORDER SHEET

Contents2

38" & Larger Vertical Run Actuated

Multi-blade Isolation Blastgate 37

Isolation Blastgate 31

16" - 36" Horizontal Run Actuated

Isolation Blastgate 32

38" & Larger Horizontal Run Actuated

Multi-blade Isolation Blastgate 33

Isolation Blastgate 35

16" - 36" Vertical Run Actuated

Isolation Blastgate 36

16" - 48" High Value Heavy Duty

Industrial Damper (HVD) 25

Field Installed Hot Tap 43

4" - 14" Industrial Short Damper ( Bal & Iso ) 21

Field Installed Lateral Saddle Tap 42

Page 3: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

L1

D1 D2

ROUND DUCT ORDER SHEET

Straight Duct3

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND003AJ

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

REMARKS

LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURESMAY REQUIRE ADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECHFOR SPECIFIC GUIDELINES.

- D2 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

COMPANY/JOB REFERENCE

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

OPTIONS

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 4: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with 2" & 3" EZ Tap ( Test Port, Drain )4

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND004AJ

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

- A1 -TAP

ORIENTATION

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8' STRAIGHTDUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWN ARE MINS. LONGER THANSTANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES MAY REQUIREADDITIONAL STIFFENERS PER SMACNA, CONTACT FAB-TECH FOR SPECIFICGUIDELINES.

TAP SPECIFICATIONSMAIN DUCT SPECIFICATIONS

EZ

D1 D2

SEE MODULAR FLANGE SYSTEM SECTIONFOR ADAPTERS AND THE EZ FITTINGSSECTION FOR DUCT TO USE WITH THE FTFLANGE. FT FLANGE / TEST PORT MAY BEINSTALLED ON FITTINGS OTHER THANSTRAIGHT DUCT.

90°

270°

180°

SPECIFYPORT/DRAIN

LOCATION ANGLEFROM 0°

EZ3/4" STD

2" - FTFL23" - FTFL3

FAB-TECH FLANGE

FAB-TECH FLANGE

VIEW OF "D1" DUCT END

L1

L2

A1

T.O.D.

3" MAX

4"MIN

L3

- L3 -TAP

LENGTH

- L2 -LOCATE TAP

FROMD1 END

FAB-TECHFLANGE

SIZE

2" FTFL23" FTFL3

2" FTFL23" FTFL3

2" FTFL23" FTFL3

2" FTFL23" FTFL3

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEMULTIPLE AND OFFSET TAPS AVAILABLE(SEE MULTIPLE TAP ORDER SHEET)DUCT GREATER THAN 84" DIAMETERREQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

REMARKS:

COMPANY/JOB REFERENCE

OPTIONS

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 5: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Straight Tap ( Not for use with 2" & 3" EZ Taps )5

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND005AJ

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

- A1 -TAP

ORIENTATION

TAP SPECIFICATIONSMAIN DUCT SPECIFICATIONS

STRAIGHT TAP

"D1" = 4" - 94": 4" MIN"D1" = 96" - 120": 5" MIN

"L1" MIN = "D3" + 8""L1" MAX = 96-1/4"

"D3" MAX = 88"

STRAIGHT TAP GREATER THAN 88" [ "D3" ]REQUIRES 2 PIECE DESIGNAND ENGINEERING REVIEW

90°

270°

180°

SPECIFY TAPLOCATION ANGLE

FROM 0°

VIEW OF "D1" DUCT END

A1

T.O.D.

L1

L2

4" MIN

D1 D2

4" MIN**MIN DISTANCE TO DUCT END

6" STD

L3D3

- D3 -TAPDIA.

- L2 -LOCATE TAP

FROMD1 END

- L3 -TAP

LENGTH

- D3 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

OUR RECOMMENDATION IS TO ADD TAPS TOSTANDARD 4' AND 8' STRAIGHT DUCT WHENPOSSIBLE - TAP DIMENSIONS SHOWN ARE MINS.LONGER THAN STANDARD LENGTHS AND/ORHIGHER SYSTEM PRESSURES MAY REQUIREADDITIONAL STIFFENERS PER SMACNA,CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

REMARKS:

COMPANY/JOB REFERENCE

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEMULTIPLE AND OFFSET TAPS AVAILABLE (SEE MULTIPLE TAP ORDER SHT)DUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

OPTIONS

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 6: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Conical Tap6

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND006AJ

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

- A1 -TAP

ORIEN-TATION

TAP SPECIFICATIONSMAIN DUCT SPECIFICATIONS

CONICAL TAP

"D1" = 4" - 94": 4" MIN"D1" = 96" - 120": 5" MIN

"L1" MIN = "D3" + 10""L1" MAX = 96-1/4"

"D3" MAX = 86"

CONICAL TAP GREATER THAN 86" [ "D3" ]REQUIRES 2 PIECE DESIGNAND ENGINEERING REVIEW

MIN DISTANCE TO DUCT END

- D3 -TAPDIA.

- L3 -TAP

LENGTH

- D3 -RINGTYPE

90°

270°

180°

SPECIFY TAPLOCATION ANGLE

FROM 0°

VIEW OF "D1" DUCT END

A1

T.O.D.

L1

D3

L2

4" MIN

D1 D2

4" MIN**

1" STD

6"

9" STD

L3

C1

1" STD

- L2 -LOCATE TAP

FROMD1 END

- C1 -BOOT

LENGTH

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

COMPANY/JOB REFERENCE

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEMULTIPLE AND OFFSET TAPS AVAILABLE (SEE MULTIPLE TAP ORDER SHT)DUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

OPTIONS

OUR RECOMMENDATION IS TO ADD TAPS TOSTANDARD 4' AND 8' STRAIGHT DUCT WHENPOSSIBLE - TAP DIMENSIONS SHOWN ARE MINS.LONGER THAN STANDARD LENGTHS AND/ORHIGHER SYSTEM PRESSURES MAY REQUIREADDITIONAL STIFFENERS PER SMACNA,CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 7: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Shoe Tap7

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND007AK

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

- A1 -TAP

ORIEN-TATION

TAP SPECIFICATIONSMAIN DUCT SPECIFICATIONS

SHOE TAP

"D1" = 4" - 94": 4" MIN"D1" = 96" - 120": 5" MIN

"L1" MIN = "D3" + 6" (SHOE LENGTH) + 8""L1" MAX = 96-1/4"

"D3" MAX = 86"

SHOE TAP GREATER THAN MAX "D3"REQUIRES 2 PIECE DESIGNAND ENGINEERING REVIEW

MIN DISTANCE TO DUCT END

- D3 -TAPDIA.

- L3 -TAP

LENGTH

- D3 -RINGTYPE

- L2 -LOCATE TAP

FROMD1 END

90°

270°

180°

SPECIFY TAPLOCATION ANGLE

FROM 0°

VIEW OF "D1" DUCT END

A1

T.O.D.

L1

L2

4" MIN

D1D2

4" MIN** 9" STD

L3

D3

6" STD

45°

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

COMPANY/JOB REFERENCE

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEMULTIPLE AND OFFSET TAPS AVAILABLE (SEE MULTIPLE TAP ORDER SHT)DUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

OPTIONS

OUR RECOMMENDATION IS TO ADD TAPS TOSTANDARD 4' AND 8' STRAIGHT DUCT WHENPOSSIBLE - TAP DIMENSIONS SHOWN ARE MINS.LONGER THAN STANDARD LENGTHS AND/ORHIGHER SYSTEM PRESSURES MAY REQUIREADDITIONAL STIFFENERS PER SMACNA,CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 8: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Lateral Tap8

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND008AJ

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

MAIN DUCT SPECIFICATIONS

45° LATERAL TAP

LATERAL TAP GREATER THAN 60" [ "D3" ]REQUIRES 2 PIECE DESIGNAND ENGINEERING REVIEW

"L1" MIN = ( "D3" X 1.414 ) + 4" + "L4"( SEE MIN LENGTH CHART ABOVE FOR "L4" )

"L1" MAX = 96-1/4""D3" MAX = 60"

90°

270°

180°

SPECIFY TAPLOCATION ANGLE

FROM 0°

VIEW OF "D1" DUCT END

A1

T.O.D.

L1

D1 D2

4" MIN*

6" MIN

D3L2

L3

L4

4" - 48"50" - 58"60" - 94"

96" - 120"

4" MIN4" MIN5" MIN6" MIN

6" MIN7" MIN8" MIN

10½" MIN

MIN LENGTH FOR "L3" AND "L4"

"L3" "L4""D1""D1" = 4" - 94": 4" MIN"D1" = 96" - 120": 5" MIN

L2 MIN DISTANCE 4" MIN

- A1 -TAP

ORIENTATION

TAP SPECIFICATIONS

- D3 -TAPDIA.

- L2 -LOCATE TAP

FROMD1 END

- L3 -TAP

LENGTH

- D3 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

COMPANY/JOB REFERENCE

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEMULTIPLE AND OFFSET TAPS AVAILABLE (SEE MULTIPLE TAP ORDER SHT)DUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

OPTIONS

OUR RECOMMENDATION IS TO ADD TAPS TOSTANDARD 4' AND 8' STRAIGHT DUCT WHENPOSSIBLE - TAP DIMENSIONS SHOWN ARE MINS.LONGER THAN STANDARD LENGTHS AND/ORHIGHER SYSTEM PRESSURES MAY REQUIREADDITIONAL STIFFENERS PER SMACNA,CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

Page 9: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Multiple Taps Spec Sheet9

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 09/30/15 RND009AM

OPTIONS

CUSTOM LENGTHS AVAILABLERAW END AVAILABLEDUCT GREATER THAN 84" DIAMETERREQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

"D1" = 4" - 94": 4" MIN"D1" = 96" - 120": 5" MIN

MIN DISTANCE TO DUCT END

1" STD

90°

270°

180°

SPECIFY TAPANGLE

FROM 0°AT D1END

L2

L2

D3

EZ

3/4" STD

D3

L36" MIN STD

2" MINFOR EZCLAMP

L2

L3

D1

6" STD

L2

D3

L3

1" MIN BETWEENANGLE RINGS

A245°STD

1/2" MINFOR ANGLE RING

D3CONICAL TAP

SHOE TAP

45° LATERAL TAP

FAB-TECH FLANGE ( SEE FAB-TECH FLANGE SYSTEM SECTION )

2" MINFOR EZCLAMPS

A1

2" OR 3"DIA.

90°

L4OFFSET

L3

L5

HORIZ.

OFFSETVERTICAL

L3

3" MAX

3" MAX FOR2" & 3" TAP

B A

DC

"D1" TAP ANGLE VIEW "D1" TAP OFFSET VIEW

L1

D2

4"MIN

5"MIN

6"MIN

7"MIN

10½"MIN

4"-48" DUCT 50"-58" DUCT 60"-94" DUCT 96"-120" DUCT2" X 2" RINGS 2-1/2" X 2-1/2" RINGS 3" X 3" RINGS 4" X 4" RINGS

STANDARD MINIMUMS FOR 45° LATERAL AND 90° STRAIGHT TAPS:

5"MIN

6"MIN

96"-120" DUCT4" X 4" RINGS

4"MIN

6"MIN

4"MIN

8"MIN

4"MIN

4"MIN

4"MIN

*

*

1" STD

L3

45°6"

STD6"

STD

9"

L2 STRAIGHT ORBULLNOSE TAP

T.O.D.

STD

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

OUR RECOMMENDATION IS TO ADD TAPS TO STANDARD 4' AND 8' STRAIGHT DUCT WHEN POSSIBLE - TAP DIMENSIONS SHOWNARE MINS. LONGER THAN STANDARD LENGTHS AND/OR HIGHER SYSTEM PRESSURES MAY REQUIRE ADDITIONAL STIFFENERSPER SMACNA, CONTACT FAB-TECH FOR SPECIFIC GUIDELINES.

- ALL FITTINGS INCLUDE ALL HARDWAREAND GASKETS TO INSTALL. -

STANDARD DUCT LENGTHS ( "L1" )

8" TO 14"

47.25"BLACK IRONANGLE RING

4" & 6"

50" TO 94"

DIAMETER"L1"

JOINT SYSTEM"L1"

( 4' ) ( 8' )

47.25"

46.75"STAINLESS

ANGLE RING50" TO 100"

95.25"

94.75"

94.75"

16" TO 48"

4" & 6" 47.25"EZ CLAMP /CAST RING 95.25"

102" TO 120" 96.25"48.25"

46.75"

47.25"8" TO 48" 95.25"

NA

NA

47.25"

9" STD

L3

Page 10: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Straight Duct with Multiple Taps10

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND010AG

- L1 -DUCT

LENGTH

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

- D2 -RINGTYPE

- L5 -VERT.

OFFSET

TAP SPECIFICATIONS

MAIN DUCT SPECIFICATIONS

- L4 -HORIZ.OFFSET

TAPQUADRANTA,B,C OR D

LOCATE OFFSET TAP

AB

C D

- L2 -LOCATE

TAP FROMD1 END

- D3 -TAPDIA.

- L3 -TAP LENGTH

- A2 -LATERALANGLEOTHER

THAN 45°

TAP#1

STRAIGHTCONICALSHOELATERALPORT/DRAIN

- A1 -TAP

ANGLE

SEE PAGE 9 FOR MULTIPLE TAP GUIDELINES

- D3 -TAP

RINGTYPE

COMPANY/JOB REFERENCE

REMARKS:

TAP#2

TAP#3

TAP#4

TAP#5

TAP#6

TAP#7

TAP#8

CUSTOM

CUSTOM LATERAL AND OFFSET TAPSPECIFICATIONS

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS ANDCLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

90°

270°

180°

45°135°

315°225°

0°A1

TYPENO.

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

STRAIGHTCONICALSHOELATERALPORT/DRAIN

ANGLE GUIDE

AB

C D

AB

C D

AB

C D

AB

C D

AB

C D

AB

C D

AB

C D

90°

270°

180° 0°

QUADRANT GUIDE

AB

C D

GUIDE REFERENCES FROM "D1" DUCT END

Page 11: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Gored Elbows11

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND011AH

- R1 -CENTERRADIUS

IN INCHES

OPTIONS

STANDARD GORES AND RADIIARE SHOWN, CUSTOM NUMBEROF GORES AND CUSTOM RADIIARE AVAILABLEDUCT GREATER THAN 84" DIAREQUIRES FAB-TECHENGINEERING REVIEW ANDAPPROVAL

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

REMARKS- D2 -RINGTYPE

- R2 -THROATRADIUS

IN INCHES

D1

D2

CL

3 GORE45° ELBOW

4 GORE60° ELBOW

5 GORE90° ELBOW

STANDARD RADIUSAT THE DUCT CENTERLINE

"R1" = 1.5 x "D"

2 GORE30° ELBOW

CL

CLCLR1

R2

"R2" = "D"STANDARD THROAT RADIUS

*

* SPECIFY EITHER CENTERLINERADIUS OR THROAT RADIUS,BOTH NOT REQUIRED

ELBOWANGLE

*

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

DUE TO MANUFACTURING LIMITATIONS, THEFOLLOWING ELBOWS ARE NOT AVAILABLE AS

FULL RADIUS 90° ELBOW > 56" DIA. FULL RADIUS 60° ELBOW > 82" DIA. FULL RADIUS 45° ELBOW > 106" DIA.

LARGE ELBOWS ABOVE THESE LIMITS WILLBE MANUFACTURED AS SMALLER FITTINGS( AN 86" DIA. 90° ELBOW WILL BE SUPPLIED

AS TWO 45° ELBOWS FOR EXAMPLE ) OR AS

ALSO DUE TO MANUFACTURING LIMITATIONS,MANY OF THE SMALLER 1/2 RADIUS ELBOWSWILL REQUIRE CAST RINGS OR FLAT RINGS.

LIMITATIONS

COMPANY/JOB REFERENCE

HALF RADIUS 90° ELBOW > 76" DIA.

ONE PIECE FITTINGS:

A CLAM SHELL DESIGNED FITTING AS TWO OR MORE PIECES. THIS APPLIES TO ALL LARGE FITTINGS AS WELL AS ELBOWS.

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 12: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Reducers12

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND012AG

OPTIONS

CUSTOM LENGTHS AVAILABLE

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

REMARKS- D2 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

CONCENTRIC

"L1" = "L2"+"L4"+"L5"

ECCENTRIC

Formula to calculate the minimum* length for reducers:

Use the charts below to determine the minimum length of "L2", "L4" and "L5":

6" AND LESS 12"

"D1" minus "D2" "L2"

7" TO 9" 18"

10" TO 13" 24"

14" TO 17" 30"

AMOUNT OFREDUCTION

MINIMUMLENGTH

9" AND LESS 12"

"D1" minus "D2" "L2"

10" TO 14" 18"

15" TO 19" 24"

20" TO 24" 30"

AMOUNT OFREDUCTION

MINIMUMLENGTH

D1D1

L2

L1

D2

L3

L2

L1

D2

"D1" or "D2" "L4" or "L5"

DUCT DIAMETERMINIMUMLENGTH

4" TO 58" 3"

60" TO 94" 4"

96" TO 120" 5"

L4 L5 L4 L5

MIN "L4" / "L5"

- L1 -DUCT

LENGTH

- L2 -TAPER

LENGTH

- L3 -CENTEROFFSET

RING TYPES

- D2 -DUCTDIA.

REMARKS:

(* Minimum length calculated to maintain minimal angular change, shorter taper lengths available.)

COMPANY/JOB REFERENCE

CENTERLINE OFFSET

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 13: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

D1

L1

D2

L2

ROUND DUCT ORDER SHEET

Offsets13

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND013AG

- L1 -DUCT

LENGTH

OPTIONS

DUCT GREATER THAN 84" DIAMETER REQUIRESFAB-TECH ENGINEERING REVIEW AND APPROVAL

- D1 -DUCTDIA.

QTY- D1 -RINGTYPE

FITTINGNUMBER

REMARKS- D2 -RINGTYPE

- L2 -OFFSETLENGTH

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

REMARKS:

COMPANY/JOB REFERENCE

- ALL FITTINGS INCLUDE ALL HARDWARE AND GASKETS TO INSTALL. -

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 14: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

End Cap14

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND014AG

OPTIONS

CLEAR POLYCARBONATE VIEWPORT ENDCAPS AVAILABLE UP TO 12" DIA.LARGER SIZES AVAILABLE WITH FAB-TECH ENGINEERING REVIEW AND APPROVAL

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

4" - 14"BLACK IRONANGLE RING

CONFIGURATION

4" - 14"PSP-EZ™

CONFIGURATION

16" - 120"ANGLE RING

CONFIGURATIONWITH ADDED

SUPPORTANGLE RING

D1D1

TRANSVERSESTIFFENERS

REQUIRED FOREND CAPS OVER

36" DIA.

1/2"

END CAP - FLAT PLATE( SEE OPTIONS )END CAP - HAT STYLE

( SEE OPTIONS )

STEELPOLY

CAPMAT'LUP TO

12" DIA

- D1 -RINGTYPE

STEELPOLY

STEELPOLY

STEELPOLY

STEELPOLY

STEELPOLY

STEELPOLY

4" - 14"CAST RING

CONFIGURATION

EZ

BI

SSEZ CLAMPS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

COMPANY/JOB REFERENCE

REMARKS:

SC STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

D1

END CAP - HAT STYLE( SEE OPTIONS )

D1

END CAP - HAT STYLESAME AS FOR EZ CONFIG( SEE OPTIONS )

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 15: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET15

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND015AH

COMPANY/JOB REFERENCE

REMARKS:

Concentric Round to Rectangular Transition

REMARKS- L2 -

THROATLENGTH

- R -RINGTYPE

- DØ -ROUND

DIAMETER

Y

X L1

3" MIN

R

L2

- L1 -DUCT

LENGTH

- X -DUCTWIDTH

QTY- Y -

DUCTHEIGHT

FITTINGNUMBER

FOR ECCENTRIC RECTANGULARTO ROUND FITTING, USE THECUSTOM FITTING ORDER SHEET.

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

ROUND RING TYPES

NOTES

RAW END AVAILABLE.DUCT WIDTH OR HEIGHT OF 98" AND LARGER REQUIRES FAB-TECH ENGINEERING REVIEW.A CENTER STIFFENER (1" SCH40 PIPE) IS ADDED AT THE MIDPOINT OF THE FLANGE FOR DUCTWIDTH OR HEIGHT OF 50" AND GREATER.

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 16: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Custom Fitting16

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND016AG

COMPANY/JOB REFERENCE

OPTIONS

DUCT GREATER THAN 84" DIAMETER REQUIRES FAB-TECH ENGINEERINGREVIEW AND APPROVAL

QTYFITTINGNUMBER

REMARKS

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPESREMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 17: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Damper Actuator Worksheet17

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND017AH

COMPANY/JOB REFERENCE

REMARKS:

ACTUATOR TYPE:

Pneumatic

Electric

Available Air Pressure

Voltage

Spring Return

Double Acting

Limit Switch

Fail Open

Fail Closed

1 Switch

2 Switch

Positioner

Position Indicator

Manual Override Gearbox

Solenoid Valves

Feedback Potentiometer

Preferred Actuator - Make and Model Number:

Accessory Part Number:

DAMPER SIZE:

CUSTOMER SELECTED:

TORQUE

25010001600

ISOLATION DAMPER

SIZE

Ø4" - Ø14"Ø16" - Ø48"Ø50" AND LARGER

RECOMMENDED MINIMUMOPEN/CLOSE TORQUE

( inch pounds )

RECTANGULAR DAMPER

1000LONGEST SIDEUP TO 48"

Page 18: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

4"-12" Wafer Isolation Damper18

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND018AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

D1

SPECIFICATIONSSOLID ALUMINUM BODY, 1” WIDTH

DUAL SHAFT, 1/2" DIAMETER STAINLESSSTEEL AXLES

®TEFLON BLADE 4” DIA. ONLY

COATED 10GA STAINLESS STEEL BLADEWITH FULLY WELDED DRIVE AXLE

EXTRUDEDFLUOROELASTOMERISOLATIONBLADE SEAL

C

C

1”

ALL COMPONENTS IN CONTACT WITH THEAIRSTREAM COATED WITH PERMASHIELDFLUOROPOLYMER BARRIER COATINGNYLON BEARINGSMANUAL LOCKING HANDLE, ALL STAINLESSSTEEL CONSTRUCTION WITH LOCKOUTCAPABILITY IN 12° INTERVALS

EXTRUDED FLUOROELASTOMER EDGE SEALLIQUID TIGHT AXLE SEALSMOLDED 25% GLASS FILLED PTFE BLADEHOLDERS

SEE ANGLE RING MECHANICALSPECIFICATION CHART FOR BOLT CIRCLEDIAMETER, BOLT HOLE SIZE AND NO. OFBOLT HOLES

NOTE:

COMPANY/JOB REFERENCE

REMARKS:

OPEN/CLOSE TORQUE: 250 in-lb( RECOMMENDED MINIMUM )

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 19: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

2" & 3" EZ Damper & EZ Blastgate19

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 12/1/14 RND019AJ

DAMPER

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

PZD02

PZD03

2" DIA ISOLATION EZ-DAMPER

3" DIA ISOLATION EZ-DAMPER

COMPANY/JOB REFERENCE

REMARKS:

BLASTGATE

PZB02

PZB03

2" DIA HORIZONTAL EZ-BLASTGATE

3" DIA HORIZONTAL EZ-BLASTGATE

PZB02V

PZB03V

2" DIA VERTICAL EZ-BLASTGATE

3" DIA VERTICAL EZ-BLASTGATE

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 20: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET20

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 09/12/16 RND020AM

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS- D1 -RINGTYPE

- D2 -RINGTYPE

4"-14" Industrial Damper - Isolation & Balancing

OPTIONS

CUSTOM EXTENDED LENGTHSCUSTOM HOLE PATTERNELECTRIC / PNEUMATIC ACTUATOR

MANUAL ACTUATION

SPECIFICATIONSFLOATING CAST RINGS - STAINLESS STEEL 4"-14" DIA.

EZ

BI

SC

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 14" )

RING TYPES

D1 D2

OPEN/CLOSE TORQUE: 250 in-lb( RECOMMENDED MINIMUM )

DAMPER STYLE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

LOCKOUT FEATURE - 1/2° INTERVALS

20GA STAINLESS STEEL ROLLED FLANGEDFUSION WELDED BODY

10GA STAINLESS STEEL BLADE

LIQUID TIGHT AXLE SEALS

6”-14” DIA.

VIRGIN TEFLON BLADE ( BALANCING )4” DIA.

MOLDED 25% GLASS FILLED PTFE BLADE3 HOLDERS

COMPANY/JOB REFERENCE

REMARKS:

FLUOROELASTOMER EDGE SEAL ( ISOLATION )

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

1/2" STAINLESS STEEL AXLES

3"

9.25" STD

EDGE SEAL

D1

FLOATING RINGS - BLACK IRON ANGLE 4"-14" DIA.PSP-EZ™ JOINING SYSTEM 4"-14" DIA

Page 21: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET21

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND021AL

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS- D1 -RINGTYPE

- D2 -RINGTYPE

4"-14" Industrial Short Damper - Isolation & Balancing

OPEN/CLOSE TORQUE: 250 in-lb( RECOMMENDED MINIMUM )

DAMPER STYLE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

ISOLATION

BALANCE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

7" MIN for D1 & D2 as Van Stone rings

D1

4-1/2" MIN for D1 as Van Stone & D2 as EZ Flange

4" MIN for D1 & D2 as EZ Flanges

ISOLATION

BALANCE

ISOLATION

BALANCE

- L1 -DAMPERLENGTH

OPTIONS

CUSTOM EXTENDED LENGTHSCUSTOM HOLE PATTERNFLOATING RINGS - BLACK IRON ANGLE 4"-14" DIA.

MANUAL ACTUATION

PSP-EZ™ JOINING SYSTEM 4"-14" DIA

SPECIFICATIONSFLOATING CAST RINGS - STAINLESS STEEL 4"-14" DIA.

LOCKOUT FEATURE - 1/2° INTERVALS

20GA STAINLESS STEEL ROLLED FLANGEDFUSION WELDED BODY

10GA STAINLESS STEEL BLADE

LIQUID TIGHT AXLE SEALS

6”-14” DIA.

VIRGIN TEFLON BLADE ( BALANCING )4” DIA.

MOLDED 25% GLASS FILLED PTFE BLADE3 HOLDERS

FLUOROELASTOMER EDGE SEAL ( ISOLATION )

1/2" STAINLESS STEEL AXLES

4-1/2" MIN for D1 & D2 as SS cast rings

D1

L1

D2

EZ

BI

SC

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 14" )

RING TYPES

L1 MIN LENGTHS:

Page 22: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

6”-14" AMCA Industrial Isolation Damper22

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND022AL

- D1 -DUCTDIA.

QTYFITTINGNUMBER

- D1 -RINGTYPE

- D2 -RINGTYPE

D1 D2

Fab-Tech, Inc. certifies that the Industrial Single Blade IsolationDamper shown herein is licensed to bear the AMCA Seal. Theratings shown are based on tests and procedures performed inaccordance with AMCA Publication 511 and comply with therequirements of the AMCA Certified Ratings Program.

The AMCA Certified Ratings Seal applies to Air Leakage ratingsand Air Performance ratings.

The AMCA Certified Ratings Seal applies to Air Leakage ratings and AirPerformance ratings.

1. Test method per AMCA Standard 500-892 Data based on a seating torque of: 764 in-lbf/ft for 6" damper,

2234 in-lbf/ft for 14" damper

2. Air leakage is based on operation between

50°F & 104°F (10°C to 40°C) and data corrected to represent3standard air density 0.075 lbs/ft .

1A 15.2 (3)*

PressureClass

N/A N/A N/A

0.25 kPa(1” wg) (4” wg) (8” wg) (12” wg)

1.0 kPa 2.0 kPa 3.0 kPa

2 3 2L/s/m (ft /min/ft )

RequiredRange

ExtendedRange (Optional)

*Units for maximum ratings in ( ) are CFM Sq. Ft.

Leakage Classification

Damper Dia.

6" - 14"1"WG 1A

Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3

Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6

Tested Leakage Rates Available, Contact Fab-Tech Inc.

Pressure AMCA Leakage Class

4",8",12"WG 1

1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14)

2 50.8 (10) 102 (20) 142 (28) 178 (35)

3 203 (40) 406 (80) 569 (112) 711 (140)

OPTIONSCUSTOM LENGTHCUSTOM HOLE PATTERNELECTRIC / PNEUMATIC ACTUATORS

FLOATING RINGS - BLACK IRON 4"-14" DIA.

MANUAL ACTUATIONFLUOROELASTOMER EDGE SEAL 6"-14"MOLDED 25% GLASS FILLED PTFE BLADE HOLDERSLIQUID TIGHT AXLE SEALSLOCKOUT FEATURE - 1/2° INTERVALS

PSP-EZ™ JOINING SYSTEM 4"-14" DIA

SPECIFICATIONSFLOATING CAST RINGS - STAINLESS STEEL 6"-14" DIA.

EZ

BISC

EZ CLAMPS( AVAILABLE 6" - 14" )

STAINLESS CAST RINGS( AVAILABLE 6" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 6" - 14" )

RING TYPES

REMARKS

OPEN/CLOSE TORQUE: 250 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

1/2"Ø STAINLESS STEEL AXLES

9.25" STD

3"EXTRUDEDFLUOROELASTOMERRUBBER EDGE SEAL

D1

AMCA

AMCA

AMCA

AMCA

AMCA

Page 23: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

16"-34" Heavy Duty Industrial Damper23

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND023AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

SPECIFICATIONS

LIQUID TIGHT SHAFT SEALS,THERMOPLASTIC SLEEVEBEARINGS

OPTIONS

1.38"Ø STAINLESS STEEL AXLES.25" STAINLESS STEEL BLADESSTAINLESS STEEL QUADRANTPLATE10GA STAINLESS STEEL BODY

PNEUMATIC ACTUATORELECTRIC ACTUATORMANUAL GEAR DRIVE

D1

CUSTOM HOLE PATTERN

MOUNTING HOLES STRADDLEVERTICAL CENTERLINE

MULTI-POSITION HANDLE,1/2° LOCKOUT FEATURE C

C

WELDED BLADE STOPSWITH VITON SEAL

WELDED STAINLESS STEEL RINGS

10" STD

5" STD

OPEN/CLOSE TORQUE: 1000 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

D1 D2

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

STAINLESS STEELQUADRANTHANDLE SHOWN

19.26"

HANDLELOCKING NUT

BLANK MOUNTING KIT ( PLATE &SHAFT ADAPTER ) FOR CUSTOMERSUPPLIED ACTUATOR

Page 24: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

16"-34" AMCA Heavy Duty Industrial Damper24

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND024AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

SPECIFICATIONS

LIQUID TIGHT SHAFT SEALS,THERMOPLASTIC SLEEVEBEARINGS

OPTIONS

1.38"Ø STAINLESS STEEL AXLES.25" STAINLESS STEEL BLADESSTAINLESS STEEL QUADRANTPLATE10GA STAINLESS STEEL BODY

PNEUMATIC ACTUATORELECTRIC ACTUATORMANUAL GEAR DRIVE

MOUNTING HOLES STRADDLEVERTICAL CENTERLINE

MULTI-POSITION HANDLE,1/2° LOCKOUT FEATUREWELDED BLADE STOPS WITHVITON SEAL

WELDED STAINLESS STEEL RINGS

Fab-Tech, Inc. certifies that the Industrial Single Blade IsolationDamper shown herein is licensed to bear the AMCA Seal. Theratings shown are based on tests and procedures performed inaccordance with AMCA Publication 511 and comply with therequirements of the AMCA Certified Ratings Program.

The AMCA Certified Ratings Seal applies to Air Leakage ratingsand Air Performance ratings.

The AMCA Certified Ratings Seal applies to Air Leakage ratings and AirPerformance ratings.

1. Test method per AMCA Standard 500-892 Data based on a seating torque of: 125 in-lbf/ft for 16" damper,

286 in-lbf/ft for 48" damper

2. Air leakage is based on operation between

50°F & 104°F (10°C to 40°C) and data corrected to represent3standard air density 0.075 lbs/ft .

1A 15.2 (3)*

PressureClass

N/A N/A N/A

0.25 kPa(1” wg) (4” wg) (8” wg) (12” wg)

1.0 kPa 2.0 kPa 3.0 kPa

2 3 2L/s/m (ft /min/ft )

RequiredRange

ExtendedRange (Optional)

*Units for maximum ratings in ( ) are CFM Sq. Ft.

Leakage Classification

Damper Dia.

16" - 34"1"WG 1A

Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3

Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6

Tested Leakage Rates Available, Contact Fab-Tech Inc.

Pressure AMCA Leakage Class

4",8",12"WG 1

1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14)

2 50.8 (10) 102 (20) 142 (28) 178 (35)

3 203 (40) 406 (80) 569 (112) 711 (140)

OPEN/CLOSE TORQUE:1000 in-lb

( RECOMMENDEDMINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

D1

C

C

10" STD

5" STD

D1 D2

STAINLESS STEELQUADRANTHANDLE SHOWN

19.26"

HANDLELOCKING NUT

CUSTOM HOLE PATTERNBLANK MOUNTING KIT( PLATE & SHAFTADAPTER ) FORCUSTOMER SUPPLIEDACTUATOR

AMCA

AMCA

AMCA

AMCA

AMCA

Page 25: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

16"-48" High Value Heavy Duty Industrial Damper (HVD)25

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND025AL

- D1 -DUCTDIA.

QTYFITTINGNUMBER

LIQUID TIGHT SHAFT SEALS -THERMOPLASTIC SLEEVE BEARINGS

OPTIONS

1.38"Ø STAINLESS STEEL AXLES.25" STAINLESS STEEL BLADESMULTI-POSITION HANDLE,1/2° LOCKOUT FEATUREBLADE OPENS CCW

PNEUMATIC ACTUATORELECTRIC ACTUATOR

STITCH WELDED RINGS 32" TO 48"DIAMETER, MOUNTING HOLESSTRADDLE VERTICAL CENTERLINE

LOOSE RINGS 16" TO 30" DIAMETERFULLY COATED BLACK IRON RINGS

SPECIFICATIONS

OPEN/CLOSE TORQUE: 1000 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

REMARKS

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

CUSTOM HOLE PATTERNBLANK MOUNTING KIT ( PLATE & SHAFT ADAPTER )FOR CUSTOMER SUPPLIED ACTUATOR

10" STD

STAINLESS STEELQUADRANT HANDLESHOWN

5" STD

19-1/4"

HANDLELOCKING NUT

*SHOWN WITH MANUAL HANDLE ACTUATOR OPTION

C

C

D1 D2

MANUAL GEAR DRIVE ACTUATORVITON BLADE SEALSTAINLESS STEEL RING

KEYED FULLY WELDED BLADE STOPS

D1

- D1 -RINGTYPEBI / SS

- D2 -RINGTYPEBI / SS

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

Page 26: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

36"-48" Heavy Duty Industrial Damper26

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 07/11/16 RND026AL

- D1 -DUCTDIA.

QTYFITTINGNUMBER

LIQUID TIGHT SHAFT SEALSTHERMOPLASTIC SLEEVEBEARINGS

OPTIONS

1.38"Ø STAINLESS STEEL AXLES.25" STAINLESS STEEL BLADES10GA STAINLESS STEEL BODYWELDED BLADE STOPS W/ VITONBLADE SEAL (3/16" X 1-1/2")

PNEUMATIC ACTUATORELECTRIC ACTUATOR

10" STD

MOUNTING HOLES STRADDLEVERTICAL CENTERLINE

LOCKOUT

GEAR DRIVE ACTUATOR WITH 5° DAMPER AXLE LOCK

WELDED STAINLESS STEEL RINGS

D1SPECIFICATIONS

C

C 5" STD

OPEN/CLOSE TORQUE: 1000 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

REMARKS

D1 D2

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

CUSTOM HOLE PATTERNBLANK MOUNTING KIT ( PLATE &SHAFT ADAPTER ) FOR CUSTOMERSUPPLIED ACTUATOR

Page 27: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

36"-48" AMCA Heavy Duty Industrial Damper27

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND027AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

LIQUID TIGHT SHAFT SEALSTHERMOPLASTIC SLEEVEBEARINGS

OPTIONS

1.38"Ø STAINLESS STEEL AXLES.25" STAINLESS STEEL BLADES10GA STAINLESS STEEL BODYWELDED BLADE STOPS WITHVITON SEAL

PNEUMATIC ACTUATORELECTRIC ACTUATOR

10" STD

MOUNTING HOLES STRADDLEVERTICAL CENTERLINE

LOCKOUT

GEAR DRIVE ACTUATOR WITH 1/2° DAMPER AXLE LOCK

WELDED STAINLESS STEEL RINGS

D1

SPECIFICATIONS

C

C 5" STDFab-Tech, Inc. certifies that the Industrial Single Blade IsolationDamper shown herein is licensed to bear the AMCA Seal. Theratings shown are based on tests and procedures performed inaccordance with AMCA Publication 511 and comply with therequirements of the AMCA Certified Ratings Program.

The AMCA Certified Ratings Seal applies to Air Leakage ratingsand Air Performance ratings.

The AMCA Certified Ratings Seal applies to Air Leakage ratings and AirPerformance ratings.

1. Test method per AMCA Standard 500-892 Data based on a seating torque of: 125 in-lbf/ft for 16" damper,

286 in-lbf/ft for 48" damper

2. Air leakage is based on operation between

50°F & 104°F (10°C to 40°C) and data corrected to represent3standard air density 0.075 lbs/ft .

1A 15.2 (3)*

PressureClass

N/A N/A N/A

0.25 kPa(1” wg) (4” wg) (8” wg) (12” wg)

1.0 kPa 2.0 kPa 3.0 kPa

2 3 2L/s/m (ft /min/ft )

RequiredRange

ExtendedRange (Optional)

*Units for maximum ratings in ( ) are CFM Sq. Ft.

Leakage Classification

Damper Dia.

36" - 48"1"WG 1A

Pressure Drop Test based on AMCA Standard 500-D-98, Ref. Fig 5.3Damper Leakage Test based on ANSI/AMCA Standard 500-D-07, Ref. Fig 5.6

Tested Leakage Rates Available, Contact Fab-Tech Inc.

Pressure AMCA Leakage Class

4",8",12"WG 1

1 20.3 (4) 40.6 (8) 55.9 (11) 71.1 (14)

2 50.8 (10) 102 (20) 142 (28) 178 (35)

3 203 (40) 406 (80) 569 (112) 711 (140)

OPEN/CLOSE TORQUE: 1000 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

REMARKS

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

D1 D2

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

CUSTOM HOLE PATTERNBLANK MOUNTING KIT( PLATE & SHAFTADAPTER ) FOR CUSTOMER SUPPLIEDACTUATOR

AMCA

AMCA

AMCA

AMCA

AMCA

Page 28: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

50" & Larger Heavy Duty Industrial Damper28

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND028AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

OPTIONSPNEUMATIC ACTUATORELECTRIC ACTUATOR

10" STD

WELDED STAINLESS STEEL RINGS

BLADE STOP

GEAR DRIVE ACTUATOR WITH LOCK OUTMOUNTING HOLES STRADDLEVERTICAL CENTERLINEWELDED BLADE STOPSLIQUID TIGHT SHAFT SEALSTHERMOPLASTIC SLEEVE BEARINGSAVAILABLE TO 120" DIA. - DAMPERSLARGER THAN 84" DIA. REQUIREENGINEERING REVIEW & APPROVAL

D1.25" STAINLESS STEEL BODY

SPECIFICATIONS.38" STAINLESS STEEL BLADE WITHSTIFFENING RIBS

5” STD

C

C

OPEN/CLOSE TORQUE: 1600 in-lb( RECOMMENDED MINIMUM )

COMPANY/JOB REFERENCE

REMARKS:

REMARKS

D1 D2

INDICATECUSTOM RINGIF REQUIRED

D1 OR D2

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

CUSTOM HOLE PATTERNBLANK MOUNTING KIT ( PLATE &SHAFT ADAPTER ) FOR CUSTOMERSUPPLIED ACTUATOR

Page 29: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

18"-72" Vortex Damper29

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND029AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

15-1/4”

SPECIFICATIONS

DRIVE RING

2-1/2” FLANGE

10 GA. STAINLESS STEEL BODY - 2-1/2" FLANGES7/16" x 11/16" SLOTTED MOUNTING HOLESMOUNTING HOLES STRADDLEVERTICAL CENTERLINE10 GA. STAINLESS STEEL BLADESWITH OVERLAP

½" DIAMETER STAINLESS STEELBLADE AXLES GLASS FILLED ETFE BEARINGSSTAINLESS STEEL LINKAGES &LINKAGES OUTSIDE AIRSTREAM1/4" STAINLESS STEEL DRIVE RING10 GA. STAINLESS STEELQUADRANT PLATE

HAND ACTUATED WITH MICROADJUSTMENT AND LOCKOUTFEATURE

LOCKOUT

DRIVEHANDLE

MICROADJUST

D1

D1

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

Page 30: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

4"-36" Horizontal Run Isolation Blastgate30

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND030AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

SPECIFICATIONSSTAINLESS STEEL FRAME MATERIALBLADE LOCKOUT SYSTEM

D1

D1

1

1

.31"

.31"

NO. OFBLADES

4" TO 16"

18" TO 36"

DIA. "D" + 4"

DIA. "D" + 4.5"

FRAMEBOLTS

DUCT DIA."D"

OUTSIDE DIM"L1"

"L1"

ANGLERING

( SEE CHART )

STAINLESSSTEEL BLADE

PTFE WIPER( TYP BOTH SIDES OF BLADE )

BLADELOCKOUT(STD)

UPPER BODY

LOWER BODYD2

- D1 -RINGTYPE

- D2 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 36" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 36" )

RING TYPES

8"STD

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

Page 31: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

16"-36" Horizontal Run Actuated Isolation Blastgate31

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND031AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

SPECIFICATIONSSTAINLESS STEEL FRAME MATERIALBLADE LOCKOUT SYSTEM

1.38"

NO. OFBLADES

16" TO 36"

2 x "D" + 30" FRAMEBOLTS

DUCT DIA."D"

- D1 -RINGTYPE

- D2 -RINGTYPE

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 16" - 36" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 36" )

RING TYPES

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

"L1"

D1 D2

D1

18"

EXTERIOR POSITION INDICATOR

"L2""D" + 12.5"

CHAINWHEELACTUATOR

OPTIONSBELLOWS ENCLOSED LEAD SCREWFOR ADDITIONAL CORROSIONRESISTANCE ( ADDS TO L1 LENGTH )

Page 32: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

38" & Larger Horizontal Run Isolation Blastgate32

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND032AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

SPECIFICATIONSSTAINLESS STEEL BODY, RINGSAND BLADESBLADE LOCKOUT SYSTEM

"L1"

8"STD

( SEE CHART )

2

3

.31"

.38"

.50"

NO. OFBLADES

38" TO 46"

48" TO 60"

86" TO 96"

DIA. "D" + 10"

DIA. "D" + 11"

DIA. "D" + 11"

BODYBOLTS

DUCT DIA."D"

OUTSIDE DIM"L1"

ANGLE RINGUPPER BODY

BLADELOCKOUT(STD)

4.63"98" and UP DIA. "D" + 11"

LOWER BODY

.38"62" TO 84" DIA. "D" + 11" 3

2

BLADE

COLLAR

SPACER

COLLAR

PTFE WIPER( TYP BOTH SIDES OF BLADE)

D1

BLADE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

D1 D2

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 38" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 38" - 120" )

RING TYPES

- D1 -RINGTYPE

- D2 -RINGTYPE

Page 33: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

38" & Larger Horizontal Run Actuated Isolation Blastgate33

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND033AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

SPECIFICATIONSSTAINLESS STEEL BODY, RINGSAND BLADESBLADE LOCKOUT SYSTEM

1.38"

NO. OFBLADES

38" TO 64"

BODYBOLTS

DUCT DIA."D"

.43"66" TO 88" 1

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 38" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 38" - 120" )

RING TYPES

- D1 -RINGTYPE

- D2 -RINGTYPE

2 x "D" + 30""L1"

D1 D2

D1

18"

EXTERIOR POSITION INDICATOR

"L2""D" + 12.5"

CHAINWHEELACTUATOR

HORIZONTAL RUN BLASTGATESGREATER THAN 88" REQUIREENGINEERING REVIEW ANDAPPROVAL

OPTIONSBELLOWS ENCLOSED LEAD SCREWFOR ADDITIONAL CORROSIONRESISTANCE ( ADDS TO L1 LENGTH )

Page 34: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

4"-36" Vertical Run Isolation Blastgate34

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND034AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

SPECIFICATIONSSTAINLESS STEEL FRAME MATERIALBLADE LOCKOUT SYSTEM

1

1

1

.31"

.31"

.31"

NO. OFBLADES

4" TO 8"

10" TO 16"

18" TO 36"

DIA. "D" + 4"

DIA. "D" + 4"

DIA. "D" + 4.5"

FRAMEBOLTS

DUCT DIA."D"

OUTSIDE DIM"L1"

15°

15°

15°

BLADEANGLE

8"

12"

16"

LENGTH"L2"

"L1"( SEE CHART )

STAINLESSSTEEL BLADE

PTFE WIPER( TYP BOTH SIDES OF BLADE )

BLADELOCKOUT(STD)

UPPERBODY

LOWERBODY

"L2"( SEE CHART )15°

D1

D1

D2

- D1 -RINGTYPE

- D2 -RINGTYPE

EZ

BI

SC

SS

EZ CLAMPS( AVAILABLE 4" - 14" )

STAINLESS CAST RINGS( AVAILABLE 4" - 14" )

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 36" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 36" )

RING TYPES

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

Page 35: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

16"-36" Vertical Run Actuated Isolation Blastgate35

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND035AI

- D1 -DUCTDIA.

QTYFITTINGNUMBER

10°

BLADEANGLE

- D1 -RINGTYPE

- D2 -RINGTYPE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

REMARKS

D1

CHAINWHEELACTUATOR

24"

SPECIFICATIONSSTAINLESS STEEL FRAME MATERIALBLADE LOCKOUT SYSTEM

1

NO. OFBLADES

16" TO 36"

DUCT DIA."D"

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 16" - 36" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 36" )

RING TYPES

EXTERIOR POSITION INDICATOR

"L2""D" + 12.5"

D1

D2

"L1"2 x "D" + 30"

.38"

FRAMEBOLTS

OPTIONSBELLOWS ENCLOSED LEAD SCREWFOR ADDITIONAL CORROSIONRESISTANCE ( ADDS TO L1 LENGTH )

Page 36: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

38" & Larger Vertical Run Isolation Blastgate36

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND036AH

SPECIFICATIONSSTAINLESS STEEL BODY, RINGS AND BLADEBLADE LOCKOUT SYSTEM

D1

2

2

3

.31"

.38"

.38"

NO. OFBLADES

38" TO 46"

48" TO 60"

62" TO 84"

DIA. "D" + 10"

DIA. "D" + 11"

DIA. "D" + 11"

BODYBOLTS

DUCT DIA."D"

OUTSIDE DIM"L1"

10°

10°

10°

BLADEANGLE

16"

24"

24"

LENGTH"L2"

UPPERBODYLOWER BODY

"L2"( SEE CHART )

BLADE

COLLAR SPACER

COLLAR

PTFE WIPER( TYP BOTH SIDES OF BLADE)

BLADE

BLADE

10°

"L1"( SEE CHART )

BLADELOCKOUT(STD)

VERTICAL RUN BLASTGATES GREATER THAN 84"REQUIRE ENGINEERING REVIEW AND APPROVAL

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 38" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 38" - 120" )

RING TYPES

- D1 -RINGTYPE

- D2 -RINGTYPE

Page 37: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

38" & Larger Vertical Run Actuated Isolation Blastgate37

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND037AI

SPECIFICATIONSSTAINLESS STEEL BODY, RINGS AND BLADEBLADE LOCKOUT SYSTEM

1

1

.38"

.43"

NO. OFBLADES

38" TO 64"

66" TO 88"

BODYBOLTS

DUCT DIA."D"

10°

10°

BLADEANGLE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 38" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 38" - 120" )

RING TYPES

- D1 -RINGTYPE

- D2 -RINGTYPE

D1

CHAINWHEELACTUATOR

24"

EXTERIOR POSITION INDICATOR

"L2""D" + 12.5"

D1

D2

"L1"2 x "D" + 30"

VERTICAL RUN BLASTGATES GREATER THAN88" REQUIRE ENGINEERING REVIEW ANDAPPROVAL

OPTIONSBELLOWS ENCLOSED LEAD SCREW FORADDITIONAL CORROSION RESISTANCE( ADDS TO L1 LENGTH )

Page 38: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Nipple38

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND038AI

QTYFITTINGNUMBER

DESCRIPTION

SPECIFICATIONSREFER TO INSTALLATION AND ASSEMBLY GUIDE

1" NPT NIPPLE - 6" DIA DUCT MIN - 16 GA MAX MATERIAL

*SWAGE KIT REQUIREDTO INSTALL NIPPLE

SEE SWAGE KIT ORDER SHEET

NIPPLE

PTFE DIE-CUT GASKET

HOST DUCT

JAMNUT

TPS01

TPS02

PARTNUMBER* DESCRIPTION

MANUAL KIT FOR 1"

HYDRAULIC KIT FOR 1", 1-1/2", & 2"

ONLY ONE KIT IS REQUIREDTO INSTALL MULTIPLE NIPPLES 1-1/2"

PARTNUMBER

PRT01

PRT15

PRT02

1-1/2" NPT NIPPLE - 8" DIA DUCT MIN - 16 GA MAX MATERIAL

2" NPT NIPPLE - 10" DIA DUCT MIN - 16 GA MAX MATERIAL

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 39: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Test Port39

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 07/14/16 RND039AI

QTYFITTINGNUMBER

DESCRIPTION

SPECIFICATIONS®NIPPLE MADE OF PURE PVDF, SEAL MADE OF VITON

STAINLESS STEEL HEX NUTABLE TO REDRILL THROUGH HOLE TO SLIGHTLY LARGERHOLE OR DRILL AND TAP TEST PORT FOR FEMALE THREADSPROVIDES LIQUID TIGHT SEAL - DOES NOT COMPROMISETHE INTEGRITY OF THE INTERIOR COATINGREFER TO INSTALLATION AND ASSEMBLY GUIDE

1/4" THROUGH HOLE MOLDED TEST PORT ( 2" DIA. DUCT MIN. )

The unique handle design of this testport allows it to be installed quickly andeasily in-the-field with common toolsand without system shutdown ordisassembly.

PARTNUMBER

1/2" THROUGH HOLE MOLDED TEST PORT ( 6" DIA. DUCT MIN. )FTFI34TP

FTFI38TP

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

9/16" THROUGH HOLE MOLDED TEST PORT ( 12" DIA. DUCT MIN. )FTFI20TP

.75"

APPROX.1-3/4"

DUCT

HEX NUT

SEAL

TO COMPLETE THEINSTALLATION, SIMPLYREMOVE THE HANDLETO EXPOSE THE PORTAND ATTACH FITTINGOR LINE.

3/8" TEST PORT

FTFI20TPFTFI34TP

FTFI38TP

Page 40: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Straight Saddle Tap40

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/07/16 RND040AI

SPECIFICATIONSSTRAIGHT TAP STANDARDOTHER TAP STYLES AVAILABLE WITHENGINEERING REVIEW AND APPROVAL

REFER TO INSTALLATION AND ASSEMBLY GUIDE

D1

HOST DUCT

STUDS AND NUTS

EXTERIORSADDLE

PTFE GASKET

THREADED & COATEDCAPS WELDED TO

® PSP SADDLE TAP

D2

SECTIONTHROUGH

DUCT

6"STD

- D1 -DUCTDIA.

QTYFITTINGNUMBER

HOST DUCT I.D., WALL THICKNESS & MATERIAL TYPE

®Fab-Tech's PSP saddle tap will allow a newbranch to be installed without shutting downthe exhaust system.

HOST DUCT I.D., WALLTHICKNESS & MATERIAL TYPE

( REQUIRED INFORMATION )

- D1 -RINGTYPE

- D2 -DUCTDIA.

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 41: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Boot Saddle Tap41

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND041AI

- D1 -DUCTDIA.

QTYFITTINGNUMBER

HOST DUCT I.D., WALL THICKNESS & MATERIAL TYPE

SPECIFICATIONS

®Fab-Tech's PSP saddle tap will allow a newbranch to be installed without shutting downthe exhaust system.

HOST DUCT I.D., WALLTHICKNESS & MATERIAL TYPE

( REQUIRED INFORMATION )

REFER TO INSTALLATION AND ASSEMBLY GUIDE

HOST DUCTTHREADED & COATEDCAPS WELDED TO

® PSP SADDLE TAP

D2

- D1 -RINGTYPE

- D2 -DUCTDIA.

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

45°

9"STD

6"STD

SECTION THROUGH DUCT - BOOT TAP

STUDS/NUTS

EXTERIORSADDLE

PTFE GASKET

D1

Page 42: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Lateral Saddle Tap42

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND042AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

HOST DUCT I.D., WALL THICKNESS & MATERIAL TYPE

SPECIFICATIONS

®Fab-Tech's PSP saddle tap will allow a newbranch to be installed without shutting downthe exhaust system.

HOST DUCT I.D., WALLTHICKNESS & MATERIAL TYPE

( REQUIRED INFORMATION )

REFER TO INSTALLATION AND ASSEMBLY GUIDE

HOST DUCT

STUDS AND NUTS

EXTERIORSADDLE

PTFE GASKET

THREADED & COATEDCAPS WELDED TO

® PSP SADDLE TAP

D2

SECTIONTHROUGH

DUCT

D1 6"STD

- D1 -RINGTYPE

- D2 -DUCTDIA.

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 43: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Hot Tap43

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND043AK

SPECIFICATIONSSTRAIGHT TAP STANDARD

REFER TO INSTALLATION AND ASSEMBLY GUIDE

- D1 -DUCTDIA.

QTYFITTINGNUMBER

HOST DUCT I.D., WALL THICKNESS & MATERIAL TYPE

HOST DUCT I.D., PRESSURECLASS & MATERIAL TYPE

( REQUIRED INFORMATION )

- D1 -RINGTYPE

- D2 -DUCTDIA.

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

SECTION THROUGH DUCT & TAP

PTFE GASKET

BACKING RING

FLUOROPOLYMERCOATED THREADEDCAPS WELDED TOBACKING RING

ANCHOR BOLT

END CAP

D1

6"STD

HOST DUCT D2

ISOLATION BOX REQUIRED FOR INSTALLATION

TapSizeØ D1

MinHostDuctØ D2

1041261461681810201222142414261628183020322234223624

Page 44: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Cast Ring44

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND044AL

QTYPARTNUMBER

DESCRIPTION

T RING THICKNESS (SEE CHART)

W

DUCTDIA"D"

H RING HEIGHT (SEE CHART)

RINGWIDTH

# H

OL

ES

BO

LT

HO

LE

SIZ

E

468

10

DU

CT

DIA

"D"

5/163/8x

5/8

6

8

5.317.509.5011.50

BO

LT

SIZ

E

BO

LT

CIR

CL

ED

IA.

WID

TH

(W)

1-1/4

HE

IGH

T(H

)

13/32

CAST RING SPECIFICATIONS

TH

ICK

NE

SS

(T)

1/8

NOTES:

CAST RINGS AVAILABLE IN STAINLESS

REFER TO CHART FOR STANDARD CAST RINGS

468

10

DU

CT

DIA

"D"

RC04

RC06

RC08

RC10

RC12

4" DIA. - STAINLESS STEEL CAST RING

6" DIA. - STAINLESS STEEL CAST RING

8" DIA. - STAINLESS STEEL CAST RING

10" DIA. - STAINLESS STEEL CAST RING

12" DIA. - STAINLESS STEEL CAST RING

1212

13.811-1/2 1/2 3/8

7/16x

11/163/16

12

14 1415.81

RC14 14" DIA. - STAINLESS STEEL CAST RING

COMPANY/JOB REFERENCE

REMARKS:

Page 45: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Angle Ring45

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND045AK

- D1 -DUCTDIA.

QTYFITTINGNUMBER

REMARKS

SPECIFICATIONSHOLES STRADDLE VERTICAL CENTERLINESTANDARD FOR WELDED ( FIXED ) RINGS

ANGLE FLANGES STANDARD ( FLAT RINGS NOTRECOMMENDED )

D1

SLOTTED HOLES STANDARDFLANGE WIDTH AND THICKNESS vs DUCT SIZESTANDARD ( SEE MECHANICAL SPECIFICATIONSIN THE STANDARDS SECTION OF CATALOG )

ADDITIONAL CHARGE FOR ALL CUSTOM RINGS

D4

D2

D3

T

W

H3H2H1

- T -RING

THICKNESS

- W -RING

WIDTH

- H3 -BOLTSIZE

- H2 -HOLESIZE

- H1 -NO.OF

HOLES

- D4 -BOLT

CIRCLEDIA.

- D3 -RINGO.D.

- D2 -RINGI.D.

- D1 -RINGTYPE

BI

SS

BLACK IRON ANGLE RINGS( AVAILABLE 4" - 100" )

STAINLESS ANGLE RINGS( AVAILABLE 16" - 120" )

RING TYPES

ADDITIONAL INFORMATION REQUIRED FOR CUSTOM ANGLE RINGS

COMPANY/JOB REFERENCE

REMARKS:

Page 46: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

PSP-EZ™ Clamp Kit46

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND046AK

QTYPARTNUMBER

REMARKS

PSP-EZ™ CLAMP KIT FOR 4" DUCTCL004KT

The PSP-EZ™ joining system®is available for standard PSP

duct from 4" to 14" in diameter.The combination of half roundbacking rings and the uniqueangled clamp band providesexcellent clamping force withthe added benefit of ease ofinstallation.

Each kit contains a clamp,PTFE tape gasket, and twobacking rings.

CL006KT

CL008KT

CL014KT

CL012KT

CL010KT

PSP-EZ™ CLAMP KIT FOR 6" DUCT

PSP-EZ™ CLAMP KIT FOR 8" DUCT

PSP-EZ™ CLAMP KIT FOR 10" DUCT

PSP-EZ™ CLAMP KIT FOR 12" DUCT

PSP-EZ™ CLAMP KIT FOR 14" DUCT

COMPANY/JOB REFERENCE

REMARKS:

Page 47: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Swage Kits47

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND047AK

QTYPARTNUMBER

DESCRIPTION

TPS01 MANUAL KIT FOR 1" FIELD INSTALLED NIPPLE

HYDRAULIC SWAGE KIT

1-5/16"PUNCH & DIE

1-5/16"SWAGE

DIES 3/8"SQUARE DRIVE

STUD WITHTHRUST WASHER

3/4" DRAW BOLTWITH NUT & WASHER

60mmSWAGE

DIES

1-5/16"SWAGE

DIES

1-7/8"SWAGE

DIES

ACTUATOR SPACERS

3/8" SLOTTEDSTUD

3/4"PUNCH& DIE

1-5/16"PUNCH & DIE1-7/8"

PUNCH & DIE60mmPUNCH & DIE

GREENLEEHYDRAULICACTUATOR

( PUMP NOT SHOWN )

THIS KIT IS USED FOR INSTALLATION OF 1" FIELD INSTALLED NIPPLESSEE INSTALLATION AND ASSEMBLY GUIDE FOR INSTALLATION INSTRUCTIONS

THIS KIT IS USED FOR INSTALLATION OF 1", 1-1/2", & 2" FIELD INSTALLED NIPPLESSEE INSTALLATION AND ASSEMBLY GUIDE FOR INSTALLATION INSTRUCTIONS

MANUAL SWAGE KIT

TPS02 HYDRAULIC KIT FOR 1", 1-1/2", & 2" NIPPLE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 48: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

PTFE Gaskets48

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND048AJ

3/16"ROPE

GASKET

All duct and fittings include gasket material forinstallation. Use this order sheet to order just gasketmaterial. When ordering, please round off quantity to

the nearest foot.

* ADHESIVE ON ONE SIDE

1/4"ROPE

GASKET

1/4" x 3/16"ROPE

GASKET

.01" THKX

.75" WIDETAPE

GASKET

* ADHESIVE ON ONE SIDE

* ADHESIVE ON ONE SIDE

* ADHESIVE ON ONE SIDE

3/16"

1/4"

1/4"

3/16"

QTYIN FEET DESCRIPTIONPART

NUMBERFITTING TYPE

GAS01*

GAS02*

GAS03*

GAS09* FOR 4" - 14" EZ JOINTS

FOR 26" - 120" DIA. ROUND & RECTANGULAR DUCT

FOR 12" - 24" DIA. DUCT

FOR 4" - 10" DIA. DUCT

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 49: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Straight Standard & Custom Length49

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND049AK

2" DUCTSTANDARDSTRAIGHT

Standardlength is47.25"

3" DUCTSTANDARDSTRAIGHT

Standardlength is47.25"

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTYPARTNUMBER

PZS02

PZS03

PZS02

PZS02

PZS02

PZS02

PZS02

PZS02

PZS03

PZS03

PZS03

PZS03

PZS03

PZS03

PZS02

PZS02

PZS03

PZS03

COMPANY/JOB REFERENCE

REMARKS:

CUSTOMLENGTH

REMARKSFITTINGTYPE

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 50: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Tees & Laterals50

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND050AJ

TEE

LATERAL

DOUBLETEE

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

2" DIA LINE - 2" DIA TEE

2" DIA LINE - 45° 2" DIA LATERAL

3" DIA LINE - 2" DIA TEE

3" DIA LINE - 45° 3" DIA LATERAL

3" DIA LINE - 3" DIA TEE

02T02

02Y02

03T02

03Y03

03T03

REDUCINGTEE

2T2T2 2" DOUBLE TEE

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 51: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Elbows51

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND051AI

90° ELBOW

45° ELBOW

30° ELBOW

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

PZE02

PZE03

PZ502

PZ302

PZ503

PZ303

2" DIA 90° ELBOW

2" DIA 45° ELBOW

2" DIA 30° ELBOW

3" DIA 90° ELBOW

3" DIA 45° ELBOW

3" DIA 30° ELBOW

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 52: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Reducers52

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND052AH

REDUCERECCENTRIC

REDUCERCONCENTRIC

ANGLE RINGTO EZ CLAMP

REDUCERCONCENTRIC

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

PCA42F

PEA42F

PCA43F

PEA43F

PCA32F

PEA32F

PCA32R

PCA42R

PCA43R

4" DIA TO 2" DIA EZ REDUCER

4" DIA TO 2" DIA EZ REDUCER

4" DIA TO 3" DIA EZ REDUCER

4" DIA TO 3" DIA EZ REDUCER

3" DIA TO 2" DIA EZ REDUCER

3" DIA TO 2" DIA EZ REDUCER

3" DIA RING TO 2" DIA EZ REDUCER

4" DIA RING TO 2" DIA EZ REDUCER

4" DIA RING TO 3" DIA EZ REDUCER

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 53: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Damper, Blastgate, Field Flange, End Cap53

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND053AG

FIELDINSTALLEDSTRAIGHTDUCT EZFLANGE

DAMPER

REPLACEMENT FT FLANGE FOR 2" & 3" DIAMETER STRAIGHT DUCT MODIFIEDOR CUT TO LENGTH IN THE FIELD, NOT DESIGNED FOR EZ ELBOWS, TEES ORREDUCERS - REFER TO INSTALLATION AND ASSEMBLY GUIDE

END CAP

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

PZD02

PZD03

HTB02

HTB03

PZC02

PZC03

2" DIA ISOLATION EZ-DAMPER

3" DIA ISOLATION EZ-DAMPER

2" FIELD FLANGE

3" FIELD FLANGE

2" DIA CAP

3" DIA CAP

BLASTGATE

PZB02

PZB03

2" DIA HORIZONTAL EZ-BLASTGATE

3" DIA HORIZONTAL EZ-BLASTGATE

PZB02V

PZB03V

2" DIA VERTICAL EZ-BLASTGATE

3" DIA VERTICAL EZ-BLASTGATE

D3673 KEYED PIN LOCK OPTION

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 54: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

EZ Clamps & Gaskets54

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND054AD

CLAMP2" & 3"

CLAMP KIT2" & 3"

DIE CUTGASKET2" & 3"

*ADHESIVE ON ONE SIDE

Refer to the catalog for specific details and dimensions.

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

CL002

CL002KT

GAS11*

CL003

CL003KT

GAS13*

2" DIE CUT GASKET ( 1 PER JOINT )

2" CLAMP ( 1 PER JOINT )

2" CLAMP AND DIE CUT PTFE GASKET

3" CLAMP ( 1 PER JOINT )

3" CLAMP AND DIE CUT PTFE GASKET

3" DIE CUT GASKET ( 1 PER JOINT )

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 55: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Fab-Tech Flange Adapters55

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND055AD

Refer to the catalog for specific details and for fitting dimensions.

Installation of Welded Fab-Tech Flange can be found onStraight Duct with Test Port / Drain Order Sheet

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FITTING TYPE

FTK25

FTPT2

FTSP2

FTK40

FTPT3

FTSP3

FTK50

FTS14

FTS38

FTS12

FTS34

®2" TO 1/4" SWAGELOK

2" TO 25mm ADAPTER

2" PITOT ADAPTER

2" SPRINKLER ADAPTER - 1" NPT

2" TO 40mm ADAPTER

3" PITOT ADAPTER

3" SPRINKLER ADAPTER - 1" NPT

2" TO 50mm ADAPTER

®2" TO 1/2" SWAGELOK

®2" TO 3/8" SWAGELOK

®2" TO 3/4" SWAGELOK

DWYER PITOTADAPTER

SPRINKLERADAPTER

FAB-TECHFLANGE

TOKF FLANGEADAPTER

®SWAGELOKADAPTER

FTS18 ®2" TO 1/8" SWAGELOK CUSTOMNOT STOCKED

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 56: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Fab-Tech Flange Adapters56

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND056AC

Refer to the catalog for specific details and for fitting dimensions.

Installation of Welded Fab-Tech Flange can be found onStraight Duct with Test Port / Drain Order Sheet

NPTNIPPLE

ADAPTER

NPTFEMALE

COUPLERADAPTER

FITTINGNUMBER

QTY DESCRIPTIONPARTNUMBER

FTF18

FTF14

FTF01

FTF15

FTF02

FTF38

FTF12

FTF34

1" NPT COATED ON FLANGE FACE ONLY

1-1/2" NPT COATED ON FLANGE FACE ONLY

2" NPT COATED ON FLANGE FACE ONLY

1/4" NPT COATED ON FLANGE FACE ONLY

3/8" NPT COATED ON FLANGE FACE ONLY

½" NPT COATED ON FLANGE FACE ONLY

3/4" NPT COATED ON FLANGE FACE ONLY

1/8” NPT COATED ON FLANGE FACE ONLY

2" FT FLANGE TO 1/8” MALE NPT

2" FT FLANGE TO 1" MALE NPT

2" FT FLANGE TO 1.5" MALE NPT

2" FT FLANGE TO 2" MALE NPT

3" FT FLANGE TO 3" MALE NPT

4" PSP-EZ™ TO 4" MALE NPT

2" FT FLANGE TO 1/4" MALE NPT

2" FT FLANGE TO 3/8" MALE NPT

2" FT FLANGE TO ½" MALE NPT

2" FT FLANGE TO 3/4" MALE NPT

FTN18

FTN01

FTN15

FTN02

FTN03

FTN04

FTN14

FTN38

FTN12

FTN34

COMPANY/JOB REFERENCE

REMARKS:

FITTINGTYPE

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 57: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed 2" Fab-Tech Flange57

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND057AC

SPECIFICATIONSREFER TO INSTALLATION AND ASSEMBLY GUIDE

EZTHREADED SPLITLOCKING RING

1.69

2"

REQUIRES DISASSEMBLY OF DUCTAND SWAGE KIT ( PN TPS02 ) TOINSTALL THIS FITTING

GASKET

FITTINGNUMBER

QTYPARTNUMBER DESCRIPTION

2" DIA FIELD INSTALLED FT FLANGEFTFL2FI

HOST DUCT(10" DIA MIN)

COMPANY/JOB REFERENCE

REMARKS:

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 58: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

ROUND DUCT ORDER SHEET

Field Installed Fab-Tech Flange Saddle Tap

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND058AB

FITTINGNUMBER

SPECIFICATIONS

REFER TO INSTALLATION AND ASSEMBLY GUIDE

D1

EZ

HOST DUCT

HOST DUCT I.D., WALLTHICKNESS & MATERIAL TYPE

( REQUIRED INFORMATION )

D2

AVAILABLE IN 2" & 3" DIAMETER SIZES ONLY ( "D1" )

2"STD

SECTIONTHROUGH

DUCT

®Fab-Tech's field installed PSP saddle tap willallow a new 2" diameter branch to be installedin a 6" and larger diameter duct or a new 3"diameter branch to be installed in an 8" andlarger diameter duct without shutting downthe exhaust system.

STUDS AND NUTS

EXTERIOR SADDLE

PTFEGASKET

INTERIOR SADDLE

PZQ02

( 6" DIA MIN. FOR 2" TAP )

2" EZ TAP

( 8" DIA MIN. FOR 3" TAP )

QTYPARTNUMBER

"D2" DUCT DIA. HOST DUCT I.D., WALL THICKNESS & TYPE DESCRIPTION

3" EZ TAPPZQ03

THREADED AND COATED CAPS® WELDED TO PSP SADDLE TAP

COMPANY/JOB REFERENCE

REMARKS:

58

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.

Page 59: Stainless Steel Corrosive Fume Exhaust Systems With ... · requires 2 piece design and engineering review min distance to duct end - d3 - tap dia. - l3 - tap length - d3 - ring type

COMPANY/JOB REFERENCE

REMARKS:

ROUND DUCT ORDER SHEET

Specialized Installation Tools59

®

Fab-Tech, Inc. / 480 Hercules Drive, Colchester, VT 05446 / Tel: 802-655-8800 / Fax: 802-655-8804 / www.fabtechinc.com

© COPYRIGHT MARCH 2014 FAB-TECH, INC. REV: 01/19/17 RND059AA

SAW GUIDE FOR CUTTING 2" DUCT

DESCRIPTIONQTYPART NUMBER

VISE2

PEXTO

VISE3

TPS01

TPS02

PIPE-CUTTER

D0700

PEXTO

PEXTO DIE

EZVGRIP

RKITPSP

HEATGUN

DBLCUT

SPARK-DES

VOLT-CONVERT

SAW GUIDE FOR CUTTING 3" DUCT

RIDGID MODEL S3 HEAVY DUTY PIPE CUTTER

CUSTOM PRESSING WHEEL ADAPTER

PEXTO MODEL 622 HAND FLANGER

CUSTOM ROLL FOR PEXTO HAND FLANGER ( NOT A SET )

EZ PLIERS

PSP FIELD REPAIR KIT ( DIRECTIONS & PSP SHEET ONLY )

BOSCH 120V HEAT GUN

D.E. STERNS SPARK TESTER

VOLTAGE CONVERTER, 220-110, 1000V, 60HZ

MANUAL KIT FOR 1" FIELD INSTALLED NIPPLE

HYDRAULIC KIT FOR 1", 1-1/2", & 2" FIELD INSTALLED NIPPLE AND FOR2" FIELD INSTALLED FAB-TECH FLANGE

MILWAUKEE 120V DOUBLE CUT SHEARS #6850

ALL DUCT FITTINGS WITH STANDARD FAB-TECH CONNECTIONS INCLUDE GASKETS AND CLAMPS OR HARDWARE AS REQUIRED FOR INSTALLATION.