STACKED TRAD CLASSIC CORNICE

24
For Internal Use: FI.PK.FIT.317_WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_Guide_Rev1.indd STACKED TRAD/CLASSIC CORNICE FITTING GUIDE 3. Unit shown for illustration purposes only. 2. 1. Unit shown for illustration purposes only. Side view Side view Unit shown for illustration purposes only. Traditional / Classic Cornice Stepped Traditional / Classic Cornice Traditional / Classic Cornice 1. Straight cut - Pages 1-4 2. External mitre joint - Pages 5-8 3. Internal mitre joint - Page 9-11 Contents: 4. Final Fit - Page 22 Stepped Traditional / Classic Cornice 1. Straight cut - Pages 12- 14 2. External mitre joint - Pages 15-18 3. Internal mitre joint - Page 19-21 Straight Cut Internal Mitre External Mitre

Transcript of STACKED TRAD CLASSIC CORNICE

Page 1: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_Guide_Rev1.indd

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

3.

Unit shown for illustration purposes only.

2.1.

Unit shown for illustration purposes only.

Side view Side view

Unit shown for illustration purposes only.

Traditional / ClassicCornice

Stepped Traditional / ClassicCornice

Traditional / Classic Cornice 1. Straight cut - Pages 1-4 2. External mitre joint - Pages 5-8 3. Internal mitre joint - Page 9-11

Contents:

4. Final Fit - Page 22

Stepped Traditional / Classic Cornice 1. Straight cut - Pages 12- 14 2. External mitre joint - Pages 15-18 3. Internal mitre joint - Page 19-21

Straight Cut Internal Mitre

External Mitre

Page 2: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 1

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Throughout the following installation guide the parts that make up this stacked traditional/classic cornice will be labelled as per the illustration on the left. Please note part D is applicable on the classic cornice only.

BEFORE YOU START

INSTALLATION SHOULD BE

PERFORMED BY A COMPETENT

PERSON ONLY.

THIS PRODUCT COULDBE DANGEROUSIF INCORRECTLY

INSTALLED

B A

C

D

Please note the stacked traditional/classic cornice should be fully assembled at

ground level then lifted into position.

200

mm

Classic Cornice Maximum height

126

mm

Classic Cornice Minimum height

200m

m

Traditional Cornice Maximum height

Please note that the stacked traditional/classic cornice has a minimum and

maximum height limitation as below.

Unit shown for illustration purposes only.

Side view

Traditional / Classic Cornice Pages 1 - 11

Page 3: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 2

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Measurement

Step 1.Measure the distance from each end of the wall units.

Step 2.Apply the measurment to part A and cut to size.

Measurement

A

A Apply measurement to this face

Step 3.Measure the inside face of part A.

Step 4.Apply measurement to the front edge of part B.

Apply measurement to this face

B

Viewed from behind

Straight Length

Page 4: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 3

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

B

Step 5.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.

A

A

B

Step 6.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked cornice will be positioned. Please refer to the minimum and maximum positions on page 1

Stacked cornice is adjustable along part A

MeasurementStep 7.Measure the outside face of part A.

A

B

Viewed from behind

Please note: if part C sits lower then part A then part A should be

cut down to size.

A CCut

Page 5: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 4

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Apply measurement to this face

Step 8.Apply measurement to the inside face of part C and cut to size.

Step 9.Apply adhesive to the back of part C. Fix part C into position using 30mm screws.

Step 10.If using the classic traditional cornice repeat steps 7-9. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

C

C

A

B

Adhesive

Viewed from behind

C

Page 6: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 5

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

AMeasurement

Inside Face

Step 13.Measure the inside face of part A (from the wall to the internal mitre).

Measurement

Apply measurement to this face

A

Step 11.Measure the distance from the wall to the front face of the decor end.

Step 12.Apply the measurement to part A and cut to size. Mitre cut the front edge (that will line up with the doors) at a 45° angle.

Plan View

Measurement

A

Viewed from behind

External Mitre Joint

Example of external mitre joint.Unit shown for illustration purposes only.

Page 7: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 6

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 15.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.

Step 16.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked cornice will be positioned. Please refer to the minimum and maximum positions on page 1

Stacked cornice is adjustable along part A

Viewed from behind

B

B

Apply measurement to this face

Step 14.Apply measurement to the front edge of part B, mitre at a 45° angle.

A

Please note: if part C sits lower then part A then part A should be

cut down to size.

A CCut

Page 8: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 7

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 18.Apply measurement to the inside face of part C and cut to size. Part C should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration right).

Apply measurement to this faceC

Viewed from behind

Measurement Extra for mitre

C

A

B Plan View

Viewed from behind

Step 19.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.

C

B

Adhesive

Measurement BStep 17.Measure the outside face of part A.

A

A

Page 9: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 8

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 20.If using the classic cornice repeat steps 17-19. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

Step 21.Repeat steps 11 - 20 to build the next adjoining cornice.

Step 22.Apply mitre adhesive to each of the mitred joints and fix together. Make sure all the mitred joints are aligned properly.

Viewed from behind

Mitre Adhesive

Assembly should be carried out at ground level and lifted into place in one piece.

Page 10: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 9

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Ai Aii

Measurement Measurement

Step 23.Take measurements from the outside face of the units to the adjacent corner points (as per illustration on the left). The front face of part A must be flush with the front face of the doors

A

DO

OR

Flus

h

Step 25.Screw through the inside face of part Ai into Aii using 30mm screws fixing both parts together.

Step 24.Cut parts A to size

Aii

AiAii

Ai

Viewed from behind

Internal Mitre Joint

Example of internal mitre joint.Unit shown for illustration purposes only.

Page 11: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 10

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

B B

Measurement

Measurement

Step 26.Measure the inside face of parts A as per the illustrationabove. Apply these measurements to parts B and cut to size.

AA

Step 27.Fix parts A and B together using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.

BB

Measurement Measurement

Step 28.Measure the outside face of part A

A A

Viewed from behind

Aii Ai

Page 12: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 11

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 30.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.

Step 31.If using the classic cornice repeat steps 28-30. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

Apply measurement to this faceC

Viewed from behind

Measurement

CPlan View

Step 29.Apply measurements to the inside face of part C and cut to size. Part C should be mitred at a 45° angle.

Viewed from behind

C

B

AAdhesive

C

For final fitting instruction please turn to page 22

Page 13: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 12

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Please note that the stepped traditional/classic Cornice has a minimum and

maximum height limitation see below.

Measurement

Step33.Measure the distance from each end of the wall units.

Step 34.Apply the measurement to part A and cut to size.

A Apply measurement to this face

Step 35.Measure the inside face of part A.

Measurement

A

Viewed from behind

219

mm

219

mm

145

mm

Traditional Cornice Maximum height Classic Cornice Maximum height Classic Cornice Minimum height

Stepped Traditional / Classic Cornice

Pages 12 - 21

Unit shown for illustration purposes only.

Side view

Straight Length

Page 14: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 13

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 36.Apply measurement to the front edge of part B.

Apply measurement to this face

B

Step 37.Placing parts A on top of parts B fix together using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws. Make sure there is a 21mm from the front of part A to the front of part B.

A

B

Step 38.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked Cornice will be positioned. Please refer to the minimum and maximum positions on page 12

Stacked Cornice is adjustable along part A

B

AViewed from behind

B

A

21mm

Please note: if part C sits lower then part A then part A should be

cut down to size.

A CCut

Page 15: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 14

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Measurement

AB

Step 39.Measure the outside face of part A.

Step 40.Apply measurement to the inside face of part C and cut to size.

Viewed from behind

Step 41.Apply adhesive to the back of part C. Fix part C into position using 30mm screws.

C

A

B

Adhesive

C

Apply measurement to this faceC

Step 42.If using the classic traditional Cornice repeat steps 39-41. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

Page 16: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 15

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Measurement

Apply measurement to this face

Step 43.Measure the distance from the wall to the front face of the decor end.

Step 44.Apply the measurement to part A and cut to size. Mitre cut the front edge (that will line up with the doors) at a 45° angle.

Plan View

Measurement

A

Step 45.Measure the outside face of part A (from the wall to the external mitre) and add 21mm.

Measurement +21mm

A

OUTSIDE FACE

External Mitre Joint

Example of external mitre joint.Unit shown for illustration purposes only.

Page 17: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 16

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 47.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 6 x 15mm screws.

Make sure there is a 21mm gap between the front faces of parts A and B.

Viewed from behind

B

B

Apply measurement to this face

Step 46.Apply measurement to the front edge of part B, mitre at a 45° angle.

A

Step 48.Measure the distance from the top of unit to the ceiling in multiple places (along the full run of units). Take the lowest of these measurements to obtain where the stacked Cornice will be positioned. Please refer to the minimum and maximum positions on page 12

Stacked Cornice is adjustable along part A

B

A

21mm

Please note: if part C sits lower then part A then part A should be

cut down to size.

A CCut

Page 18: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 17

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 50.Apply measurement to the inside face of part C and cut to size. Part C should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration right).

Apply measurement to this faceC

Viewed from behind

Measurement Extra for mitre

C

A

B

Plan View

Viewed from behind

Step 51.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.

C

B

Adhesive

Measurement

BStep 49.Measure the outside face of part A.

A

A

Page 19: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 18

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 52.If using the classic cornice repeat steps 49-51. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

Step 53.Repeat steps 43 - 51 to build the next adjoining cornice.

Step 54.Apply mitre adhesive to each of the mitred joints and fix together. Make sure all the mitred joints are aligned properly.

Viewed from behind

Mitre Adhesive

Assembly should be carried out at ground level and lifted into place in one piece.

Page 20: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 19

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Ai Aii

Measurement Measurement

Step 55.Take measurements from the outside face of the units to the adjacent corner points (as per illustration on the left). The front face of part A must be flush with the front face of the doors

A

DO

OR

Flus

h

Step 57.Screw through the inside face of part Ai into Aii using 30mm screws fixing both parts together.

Step 56.Cut parts A to size

AiAii

AiiAi

Viewed from behind

Internal Mitre Joint

Example of internal mitre joint.Unit shown for illustration purposes only.

Page 21: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 20

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 58.Measure the outside face of parts A as per the illustration above.

B

Viewed from behind

Measurement

AiiAiMeasurement

Apply measurement to this face

B

Measurement Extra for

mitre

B

Plan View

Step 59.Apply measurement to the front face of part B and cut to size. Part B should be mitred at a 45° angle, make sure to add extra material to the measurement in order to achieve the required mitre joint (see illustration above).

B

A

21mm

Step 60.Fix together parts A and B using ‘L’ brackets. Fix each ‘L’ Bracket into place using 15mm screws.

Make sure there is a 21mm gap between the front faces of parts A and B.

B

Aii Ai

Page 22: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 21

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 61.Measure the outside face of part A.

Measurement Measurement

A A

Step 64.If using the classic cornice moulding repeat steps 61-63. Make sure the top face of part D is touching the bottom face of part C.

Apply measurement to this face

DInside Face

Viewed from behind

A

C

DFlush

Apply measurement to this faceC

Viewed from behind

Step 63.Apply adhesive to the back face of part C. Fix part C into position using 30mm screws.

Adhesive

Viewed from behind

C

B

A

Measurement

CPlan View

Step 62.Apply measurements to the inside face of part C and cut to size. Part C should be mitred at a 45° angle.

Page 23: STACKED TRAD CLASSIC CORNICE

For Internal Use: FI.PK.FIT.317_50-WKIN00360_STACKED_TRAD/CLASSIC_CORNICE_ Guide_Rev1.indd Page 22

STACKED TRAD/CLASSICCORNICE

FITTING GUIDE

Step 66.Secure the stacked cornice in place by screwing up through the unit top fixed shelves into part B using 30mm screws. Conceal the screw heads using the screw caps provided.

Do

or/

Dec

or

end

Part A

Flus

h

Final Fit

Step 65.Lift the assembled stacked cornice onto the top of the wall units making sure the outside face of Part A is flush with the decor end/doors. Please note this step should be carried out by a minimum of two people.

Stacked Traditional / Classic Cornice