SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power...

56
AIR CONDITIONERS SSB S-CLASS ® SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ Bulletin No. 210466 November 2017 Supersedes August 2017 SEER up to 16.50 3 to 5 Tons Cooling Capacity - 34,400 to 57,500 Btuh MODEL NUMBER IDENTIFICATION S S B 036 H 4 S 4 1 Y Cooling Efficiency H = High Efficiency Unit Type S = Split System Air Conditioner Major Design Sequence A = 1st Generatio B = 2nd Generation Nominal Cooling Capacity 036 = 3 tons 048 = 4 tons 060 = 5 tons Minor Revision Number 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Voltage Y = 208/230V-3phase-60hz G = 460V-3phase-60hz Refrigerant Type 4 = R-410A Brand/Family S = S-Class™ Product Line Part Load Capability S = Part load capabilities with multi-stage operation Coil Type 4 = Four-sided PRODUCT SPECIFICATIONS

Transcript of SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power...

Page 1: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

A I R C O N D I T I O N E R S

SSBS-CLASS® SPLIT SYSTEM

R-410A - Two-Stage Compressor - 60 HZBulletin No. 210466

November 2017 Supersedes August 2017

SEER up to 16.503 to 5 Tons

Cooling Capacity - 34,400 to 57,500 Btuh

MODEL NUMBER IDENTIFICATION

S S B 036 H 4 S 4 1 Y

Cooling Efficiency H = High Efficiency

Unit Type S = Split System Air Conditioner

Major Design Sequence A = 1st Generatio

B = 2nd Generation

Nominal Cooling Capacity 036 = 3 tons 048 = 4 tons 060 = 5 tons

Minor Revision Number 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision

Voltage Y = 208/230V-3phase-60hz G = 460V-3phase-60hz

Refrigerant Type 4 = R-410A

Brand/Family S = S-Class™ Product Line

Part Load Capability S = Part load capabilities with multi-stage operation

Coil Type 4 = Four-sided

P R O D U C T S P E C I F I C AT I O N S

SSB 3-5 TON AIR CONDITIONERS

Page 2: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 2

WARRANTY

Compressor - Limited warranty for five years in non-residential installations.

All other covered components - One year in non-residential installations.

Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

APPROVALSAHRI Certified to AHRI Standard 210/240-2008.Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008.Tested in the Lennox Research Laboratory environmental test room.Rated according to U.S. Department of Energy (DOE) test procedures.Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC.Units are ETL certified for the U.S. and Canada.ISO 9001 Registered Manufacturing Quality System.For expanded ratings, see www.LennoxPROs.com.

APPLICATIONSSEER up to 16.50.3 through 5 ton.Three phase power supply.Sound levels as low as 76 dB.Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI Ratings tables.Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation.Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job.

FEATURES

B

C

D

E

F

G

H

J

CONTENTSAHRI System Matches............................................... 11Dimensions - Inches (Mm) ........................................... 9Electrical Data.............................................................. 7Features....................................................................... 2Installation Clearances ................................................ 8Model Number Identification ........................................ 1Optional Accessories - Order Separately..................... 7Optional Conventional Temperature Control Systems . 6Sound Data .................................................................. 8Specifications............................................................... 7

I

Page 3: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 3

REFRIGERATION SYSTEMR-410A RefrigerantNon-chlorine, ozone friendly, R-410A.Unit is factory pre-charged.See Specification table.

Outdoor Coil FanDirect drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. SSB048H4 (208/230V-3ph) models have a variable-speed outdoor fan motor for quiet operation.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has ball bearings and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosionFan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel.Fan service access accomplished by removal of fan guard.

Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil.Ripple-edged aluminum fins.Copper tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections/silver soldering construction.Coil is factory tested under high pressure to insure leakproof construction.Entire coil is accessible for cleaning.

High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Auto-reset.

Low Pressure SwitchShuts off unit if suction pressure falls below setting.Provides loss of charge and freeze-up protection.Auto-reset.

Hi-Capacity Liquid Line DrierFactory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system.100% molecular-sieve bead type drier.

AB

C

D

E

F

Optional Accessories

Expansion Valve KitsMust be ordered separately and field installed on certain indoor units. See Thermal Expansion Valve (TXV) table.Chatleff style fitting.

FreezestatInstalls on or near the discharge line of the evaporator or on the suction line.Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint.Opens at 29°F and closes at 58°F.

Refrigerant Line KitsRefrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory.Suction line fully insulated.L15 lines are stubbed at both ends.See Specifications table for selection.Not available for -060 model and must be field fabricated.

FEATURES

Page 4: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 4

COMPRESSORCopeland Scroll Ultra Tech™ Two-Stage CompressorCompressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged.During the compression process, there are several pockets in the scroll that are compressing gas. Modulation is achieved by venting a portion of the gas in the first suction pocket back to the low side of the compressor thereby reducing the effective displacement of the compressor.

G

A 24-volt DC solenoid valve inside the compressor controls staging. When the 3-way solenoid is energized it moves the lift ring assembly to block the ports and the compressor operates at full-load or 100% capacity. When the solenoid is de-energized the lift ring assembly moves to unblock the compressor

ports and the compressor operates at part-load or approximately 67% of its full-load capacity.The “loading” and “unloading” of the two stage scroll is done “on the fly” without shutting off the single-speed compressor motor between stages.Low gas pulses during compression reduces operational sound levels.Compressor motor is internally protected from excessive current and temperature.Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation.

Crankcase HeaterCrankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication.

FEATURES

Page 5: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 5

CONTROLS

Optional Accessories

L Connection® NetworkComplete building automation control system for single or multi-zone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Product Specifications Bulletin for details.

Compressor Low Ambient Cut-Off SwitchNon-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F.Indoor Blower Off Delay RelayDelays the indoor blower-off time during the cooling cycle.See AHRI System Matches for usage.

Indoor Blower Speed Relay KitRelay kit provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan or first-stage compressor operation.

Low Ambient ControlAir conditioners operate satisfactorily down to 45°F outdoor air temperature without any additional controls.Two low ambient control options are available for field installation:1. Low Ambient Control Kit (30°F) - Allows unit

operation down to 30°F.2. Low Ambient Control (0°F) - Allows unit operation

down to 0°F. Requires Speed Control and Weatherproof Kit (ordered separately). Available for 208/230V models only.

NOTE - Freezestat should be installed on compressors equipped with a Low Ambient Kit.

Monitor Kit - Service LightContains ambient compensating thermistor and service light thermostat.For use with thermostats requiring input for indicator lights.

Outdoor Thermostat KitAn outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two-stage control is applicable.Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line.Thermostat kit and mounting box must be ordered separately.

CABINETHeavy-gauge steel constructionPre-painted cabinet finish.Control box is conveniently located with all controls factory wired.Large removable panel provides service access.Drainage holes are provided in base section for moisture removal.High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture.

PermaGuard™ Unit BaseDurable zinc-coated base section resists rust and corrosion.

SmartHinge™ Louvered Coil ProtectionSteel louvered panels provides complete coil protection.Panels are hinged to allow easy cleaning and servicing of coils.Panels may be completely removed.Interlocking tabs and slots assure tight fit on cabinet.

Refrigerant Line Connections, Electrical Inlets and Service ValvesVapor and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing.

H

I

J

FEATURES

Page 6: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 6

OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS

Item Model No.

Catalog No.

COMFORTSENSE® 7500 COMMERCIAL 7-DAY PROGRAMMABLE THERMOSTAT

• Four-Stage Heating / Two-Stage Cooling Universal Multi-Stage• Intuitive Touchscreen Interface• Remote Indoor Temperature Sensing with Averaging• Outside or Discharge Air Temperature Display• Full Seven-Day Programming• Four Time Periods Per Day• Occupancy Scheduling with Economizer Relay Control• Away Mode• Holiday Scheduling• Smooth Setback Recovery (SSR)• Performance Reports• Notifications/Reminders• Dehumidification/Humiditrol® Control for Split Systems and Rooftop Units• Economizer Relay Control• Backlit Display• Wallplate Furnished

C0STAT06FF1L 13H15

Optional Accessories1 Remote non-adjustable wall mount 20k temperature sensor C0SNZN01AE2- 47W361 Remote non-adjustable wall mount 10k temperature sensor C0SNZN73AE1- 47W37Remote non-adjustable discharge air (duct mount) temperature sensor C0SNDC00AE1- 19L22Outdoor temperature sensor C0SNSR03AE1- X2658Locking cover (clear) C0MISC15AE1- 39P211 R emote sensors can be applied in any of the following combinations:

One Sensor - (1) 47W36 Two Sensors - (2) 47W37 Three Sensors - (2) 47W36 and (1) 47W37 Four Sensors - (4) 47W36 Five Sensors - (3) 47W36 and (2) 47W37

COMFORTSENSE® 3000 COMMERCIAL 5-2 DAY PROGRAMMABLE THERMOSTAT

MAINT

Commercial

• Two-Stage Heating / Two-Stage Cooling Conventional Systems• Intuitive Interface• 5-2 Day Programming• Program Hold• Remote Indoor Temperature Sensing• Smooth Setback Recovery (SSR)• Economizer Relay Control• Maintenance/Filter/Service Reminders• Backlit Display• Wallplate Furnished• Simple Up and Down Temperature Control.

C0STAT05FF1L 11Y05

Optional AccessoriesRemote non-adjustable wall mount 10k averaging temperature sensor C0SNZN73AE1- 47W37Optional wall mounting plate C0MISC17AE1- X2659DIGITAL NON-PROGRAMMABLE THERMOSTAT

• One-Stage Heating / Cooling Conventional Systems• Intuitive Interface• Automatic Changeover• Backlit Display• Simple Up and Down Temperature Control.

C0STAT12AE1L 51M32

Optional AccessoriesOutdoor temperature sensor C0SNSR04AE1- X2658Optional wall mounting plate C0MISC17AE1- X2659

Page 7: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 7

SPECIFICATIONSGeneral Data

Model No. SSB036H4 SSB048H4 SSB060H4Nominal Tonnage 3 4 5

Connections (sweat)

Liquid line (o.d.) - in. 3/8 3/8 3/8Suction line (o.d.) - in. 7/8 7/8 1-1/8

Refrigerant 1 R-410A charge furnished 8 lb. 6 oz. 10 lb. 7 oz. 12 lb. 1 oz.Outdoor Coil

Net face area - sq. ft. - Outer coil 16.33 21.00 29.09Inner coil 15.76 20.27 28.24

Tube diameter - in. 5/16 5/16 5/16No. of rows 2 2 2

Fins per inch 22 22 22Outdoor Fan

Diameter - in. 22 22 26No. of blades 4 4 3

Motor hp 1/4 1/3 1/3Voltage 208/230/460V-3ph 208/230V -3ph 460V-3ph 208/230/460V-3ph

Cfm - 1st stage 3500 3190 3955 43252nd stage - - - 3700 - - - - - -

Rpm - 1 stage 825 705 835 8652nd stage - - - 820 - - - - - -

Watts - 1st stage 300 165 320 2402nd stage - - - 260 - - - - - -

Shipping Data - lbs. 1 pkg. 243 268 332

ELECTRICAL DATALine voltage data - 60hz

2 Maximum overcurrent protection (amps)3 Minimum circuit ampacity

208/230V-3ph 460V-3ph 208/230V-3ph 460V-3ph 208/230V-3ph 460V-3ph25 10 30 15 35 20

16.2 8.0 20.3 9.1 22.4 10.05Compressor Rated load amps 11.6 5.7 14 6.41 16.5 7.24

Locked rotor amps 73 38 83.1 41 110 52Power factor 0.99 0.99 0.99 0.99 0.99 0.99

Outdoor Fan Motor

Full load amps 1.7 0.9 2.8 0.9 1.8 1.0Locked Rotor amps 2.1 1.1 N/A 2.1 2.9 2.0

OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Low Ambient Cut-Off Switch 45F08 • • •Compressor Time-Off Control 47J27 • • •Freezestat 3/8 in. tubing 93G35 • • •

5/8 in. tubing 50A93 • • •Indoor Blower Off Delay Relay 58M81 • • •Indoor Blower Speed Relay Kit 40K58 • • •4 Low Ambient Kit (Fan Cycling)

(down to 30°F)34M72 • •68M04 •

4 Low Ambient Control (0°F) 208/230V only

Speed Control X5867 • •Weatherproof Kit 56N41 • •

Refrigerant Line Sets L15-65-30 L15-65-40 L15-65-50

• •

Field Fabricate •NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

additional refrigerant charge required.2 HACR type breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Freezestat is recommended with Low Ambient Control.

Page 8: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 8

SOUND DATA

Unit Model No.

1 Sound Rating Number (dB)125 250 500 1000 2000 4000 8000

SSB036H4 70.6 67.9 66.7 63.1 57.5 54.7 55.4 74SSB048H4 64.7 64.1 65.8 65.2 60.3 56.1 53.7 74SSB060H4 68.9 67 66.4 67.4 58.9 57.3 52.5 74NOTE - the octave sound power data does not include tonal correction.1 Tested according to AHRI Standard 270-2008 test conditions.

SeeNOTES

See NOTES

SeeNOTES

See NOTES ControlBox

INSTALLATION CLEARANCES

NOTES:Service clearance of 30 in. (762 mm) must be maintained on one of

the sides adjacent to the control box.Clearance to one of the other three sides must be 36 in. (914 mm).Clearance to one of the remaining two sides may be 12 in. (305 mm)

and the final side may be 6 in. (152 mm).A clearance of 24 in. (610 mm) must be maintained between two units.48 in. (1219 mm) clearance required on top of unit.

Page 9: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 9

ELECTRICALINLETS

SIDE VIEW

DISCHARGE AIR

SUCTION LINECONNECTION

LIQUID LINECONNECTION

A

BC

4-1/4(108)4-3/4(121)

1 (25)

2 (51)

END VIEW

TOP VIEW

SUCTION LINECONNECTION

LIQUID LINECONNECTION

UNIT SUPPORTFEET

BASE SECTION(Medium and Large Base)

D K

GF

EJ

H

DIMENSIONS - INCHES (MM)

Model No.A B C D E F G H J K

in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mmSSB036H4 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524SSB048H4 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524SSB060H4 45 1143 35-1/2 902 39-1/2 1003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683

Page 10: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 10

MOST POPULAR MATCHESOutdoor Unit Model No.

Indoor Unit Model No.

SSB036H4 CX34-43C-6FSSB048H4 CX34-62C-6FSSB060H4 CX34-62C-6F

TXV USAGEUse this table for C33, CH23, CH33, CH35 and CR33 Field Installed TXV Match-Ups.Outdoor Unit Model No.

Order No.

SSB036H4 12J19SSB048H4 12J20SSB060H4 12J20CX34 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered and field installed.C33 coils and all horizontal and downflow coils are shipped without a TXV. The TXV must be ordered and field installed.

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.

Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

*TXV SUBSTITUTIONSUse this table to determine if the factory installed TXV in the indoor unit needs to be replaced.

Outdoor Unit Model No. Air Handler Factory

TXVReplacement TXV

SSB036H4 CBX25UH-030 12J18 12J19

SSB036H4 CBX32M-030 12J18 12J19

SSB036H4 CBX32MV-024/030 12J18 12J19

SSB036H4 CBX40UHV-030 12J18 12J19* Air handlers - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used.

Page 11: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 11

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 35000 14.5 11.7 C35-30/36A EL180UH045E36A 10247463SSB036H4S (208/230V) TXV 35000 15 11.7 C35-30/36A SL280UH070V36A 10247464SSB036H4S (208/230V) TXV 35000 15 11.7 C35-30/36A SL280UH070XV36A 10247465SSB036H4S (208/230V) TXV 35000 15 11.7 C35-30/36B EL180UH070E36B 10247466SSB036H4S (208/230V) TXV 34800 14.5 11.7 C35-30/36B EL195UH045XE36B 10247468SSB036H4S (208/230V) TXV 34800 14.5 11 C35-30/36B EL195UH070XE36B 10247467SSB036H4S (208/230V) TXV 34800 14.5 11 C35-30/36B EL296UH045XE36B 10247470SSB036H4S (208/230V) TXV 34800 15 11.7 C35-30/36B EL296UH045XV36B 10247469SSB036H4S (208/230V) TXV 34800 14.5 11.7 C35-30/36B EL296UH070XE36B 10247471SSB036H4S (208/230V) TXV 35200 15 12 C35-30/36B SL280UH090V36B 10247472SSB036H4S (208/230V) TXV 35000 15 12 C35-30/36B SL280UH090V48B 10247473SSB036H4S (208/230V) TXV 35200 15 12.2 C35-30/36B SL280UH090XV48B 10247474SSB036H4S (208/230V) TXV 35000 15 11.7 C35-30/36B SLP98UH070XV36B 10247475SSB036H4S (208/230V) TXV 34800 15 12 C35-30/36C CBWMV-036C-090 10247476SSB036H4S (208/230V) TXV 34800 15 12 C35-30/36C EL296UH090XV48C 10247477SSB036H4S (208/230V) TXV 35000 15 12 C35-30/36C EL296UH110XV48C 10247478SSB036H4S (208/230V) TXV 35400 15 12.2 C35-30/36C EL296UH110XV60C 10247479SSB036H4S (208/230V) TXV 35400 15 12 C35-30/36C SL280UH090V60C 10247480SSB036H4S (208/230V) TXV 35400 15.1 12 C35-30/36C SL280UH090XV60C 10247481SSB036H4S (208/230V) TXV 35200 15 12 C35-30/36C SL280UH110V60C 10247482SSB036H4S (208/230V) TXV 35400 15 12 C35-30/36C SL280UH110XV60C 10247483SSB036H4S (208/230V) TXV 35000 15 12 C35-30/36C SLP98UH090XV36C 10247484SSB036H4S (208/230V) TXV 35200 15 12 C35-30/36C SLP98UH090XV48C 10247485SSB036H4S (208/230V) TXV 35600 15 12 C35-30/36C SLP98UH090XV608C 10247486SSB036H4S (208/230V) TXV 35400 15 12.2 C35-30/36C SLP98UH110XV60C 10247487SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36A EL180UH045E36A 10247488SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36A EL180UH045XE36A 10247491SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36A SL280UH070V36A 10247489SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36A SL280UH070XV36A 10247490SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36B EL180UH070E36B 10247492SSB036H4S (208/230V) TXV 36200 15 11.7 C35-36B EL195UH045XE36B 10247493SSB036H4S (208/230V) TXV 36200 15.5 12.2 C35-36B EL195UH070XE36B 10247494SSB036H4S (208/230V) TXV 36200 15 11.7 C35-36B EL296UH045XE36B 10247496SSB036H4S (208/230V) TXV 36200 15.5 12.2 C35-36B EL296UH045XV36B 10247495SSB036H4S (208/230V) TXV 36200 15.5 12.2 C35-36B EL296UH070XE36B 10247497SSB036H4S (208/230V) TXV 36600 15.5 12.5 C35-36B SL280UH090V36B 10247498SSB036H4S (208/230V) TXV 36600 15.5 12.5 C35-36B SL280UH090V48B 10247499SSB036H4S (208/230V) TXV 36600 15.5 12.5 C35-36B SL280UH090XV48B 10247500SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-36B SLP98UH070XV36B 10247501SSB036H4S (208/230V) TXV 35800 14 11 C35-36B 10250502SSB036H4S (208/230V) TXV 36600 15.5 12.2 C35-48B EL180UH070E36B 10247502SSB036H4S (208/230V) TXV 36400 15 11.7 C35-48B EL195UH045XE36B 10247503SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-48B EL195UH070XE36B 10247504NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 12: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 12

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 36400 15 11.7 C35-48B EL296UH045XE36B 10247506SSB036H4S (208/230V) TXV 36600 15.5 12.2 C35-48B EL296UH045XV36B 10247505SSB036H4S (208/230V) TXV 36400 15.5 12.2 C35-48B EL296UH070XE36B 10247507SSB036H4S (208/230V) TXV 36600 15.5 12.2 C35-48B EL296UH070XV36B 10247508SSB036H4S (208/230V) TXV 37000 16 12.5 C35-48B SL280UH090V36B 10247509SSB036H4S (208/230V) TXV 36000 16 12.5 C35-48B SL280UH090V48B 10247510SSB036H4S (208/230V) TXV 36000 16 12.5 C35-48B SL280UH090XV48B 10247511SSB036H4S (208/230V) TXV 36600 15.5 12.2 C35-48B SLP98UH070XV36B 10247512SSB036H4S (208/230V) TXV 36600 15.5 12.5 C35-48C CBWMV-36C-090 10247513SSB036H4S (208/230V) TXV 37000 16 12.5 C35-48C CBWMV-60C-100 10247514SSB036H4S (208/230V) TXV 36600 16 12.5 C35-48C EL296UH110XV48C 10247515SSB036H4S (208/230V) TXV 36600 15.1 12 C35-48C SL280UH090V60C 10247516SSB036H4S (208/230V) TXV 37000 15.1 12.5 C35-48C SL280UH090XV60C 10247517SSB036H4S (208/230V) TXV 36800 15.1 12.5 C35-48C SL280UH110V60C 10247518SSB036H4S (208/230V) TXV 36800 15.1 12.5 C35-48C SL280UH110XV60C 10247519SSB036H4S (208/230V) TXV 36800 15.5 12.5 C35-48C SLP98UH090XV36C 10247520SSB036H4S (208/230V) TXV 36800 16 12.5 C35-48C SLP98UH090XV48C 10247521SSB036H4S (208/230V) TXV 37200 16 12.5 C35-48C SLP98UH090XV60C 10247522SSB036H4S (208/230V) TXV 37000 15.5 12.5 C35-48C SLP98UH110XV60C 10247523SSB036H4S (208/230V) TXV 36200 14 11.7 C35-48C 10250503SSB036H4S (208/230V) TXV 37600 16 12.5 C35-49C SL280UH090V60C 10247524SSB036H4S (208/230V) TXV 37600 16 12.5 C35-49C SL280UH090XV60C 10247525SSB036H4S (208/230V) TXV 37200 15.1 12.5 C35-49C SL280UH110V60C 10247526SSB036H4S (208/230V) TXV 37400 15.1 12.5 C35-49C SL280UH110XV60C 10247527SSB036H4S (208/230V) TXV 37000 16 12.5 C35-49C SLP98UH090XV36C 10247528SSB036H4S (208/230V) TXV 37400 16 12.5 C35-49C SLP98UH090XV48C 10247529SSB036H4S (208/230V) TXV 37600 16 12.5 C35-49C SLP98UH090XV60C 10247530SSB036H4S (208/230V) TXV 37400 16 12.5 C35-49C SLP98UH110XV60C 10247531SSB036H4S (208/230V) TXV 36400 14 11.7 C35-49C 10250504SSB036H4S (208/230V) TXV 36400 16 12.5 C35-50/60C EL296UH110XV48C 10247532SSB036H4S (208/230V) TXV 36000 15 12.2 CBA27UHE-036 10259516SSB036H4S (208/230V) TXV 36000 16 12.5 CBA27UHE-042 10259517SSB036H4S (208/230V) TXV 34800 13 11 CBX25UH-030 6513788SSB036H4S (208/230V) TXV 35800 15 12.2 CBX27UH-036 6513170SSB036H4S (208/230V) TXV 37000 16 12.5 CBX27UH-042 6513172SSB036H4S (208/230V) TXV 35200 14.5 11.7 CBX32M-030 6513174SSB036H4S (208/230V) TXV 35400 14.5 11.7 CBX32M-036 6513176SSB036H4S (208/230V) TXV 35600 14.5 11.7 CBX32M-042 6513178SSB036H4S (208/230V) TXV 35600 15 12 CBX32MV-024/030 6513199SSB036H4S (208/230V) TXV 36000 15.5 12 CBX32MV-036 6513201SSB036H4S (208/230V) TXV 37000 16 12.5 CBX32MV-048 6513390SSB036H4S (208/230V) TXV 35400 15 11.7 CBX40UHV-030 6513792SSB036H4S (208/230V) TXV 35200 15 12 CBX40UHV-036 6513794NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 13: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 13

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 36600 15.5 12.2 CBX40UHV-042 6513796SSB036H4S (208/230V) TXV 36600 15 12.5 CBX40UHV-048 6513798SSB036H4S (208/230V) TXV 35600 15 12 CH23-41 EL180UH070E36B 6513802SSB036H4S (208/230V) TXV 35600 14.5 11.7 CH23-41 EL195UH045XE36B 6513394SSB036H4S (208/230V) TXV 35400 15 12 CH23-41 EL195UH070XE36B 6513397SSB036H4S (208/230V) TXV 35200 14.5 11 CH23-41 EL296UH045XE36B 6513804SSB036H4S (208/230V) TXV 35200 14.5 11 CH23-41 EL296UH070XE36B 6513806SSB036H4S (208/230V) TXV 35400 15.5 12 CH23-41 EL296UH070XV36B 6513800SSB036H4S (208/230V) TXV 35600 15.5 12.2 CH23-41 EL296UH090XV36C 6513807SSB036H4S (208/230V) TXV 35400 15.5 12.2 CH23-41 EL296UH090XV48C 6513809SSB036H4S (208/230V) TXV 36000 15.5 12.2 CH23-41 EL296UH090XV60C 6513811SSB036H4S (208/230V) TXV 35600 15.5 12.5 CH23-41 EL296UH110XV48C 6513399SSB036H4S (208/230V) TXV 36000 15.5 12.5 CH23-41 EL296UH110XV60C 6513813SSB036H4S (208/230V) TXV 35400 15.5 12.5 CH23-41 SL280UH090V36B 6513205SSB036H4S (208/230V) TXV 35600 15 12.5 CH23-41 SL280UH090V48B 6513207SSB036H4S (208/230V) TXV 36000 15.1 12.5 CH23-41 SL280UH090V60C 6513209SSB036H4S (208/230V) TXV 35600 15.5 12.5 CH23-41 SL280UH090XV48B 6513815SSB036H4S (208/230V) TXV 36000 15.1 12.5 CH23-41 SL280UH090XV60C 6513817SSB036H4S (208/230V) TXV 35800 15.1 12.2 CH23-41 SL280UH110V60C 6513210SSB036H4S (208/230V) TXV 35800 15.1 12.2 CH23-41 SL280UH110XV60C 6513819SSB036H4S (208/230V) TXV 35400 15.5 12 CH23-41 SLP98UH070XV36B 6513212SSB036H4S (208/230V) TXV 35600 15.5 12.2 CH23-41 SLP98UH090XV36C 6513214SSB036H4S (208/230V) TXV 35400 15.5 12.2 CH23-41 SLP98UH090XV48C 6513216SSB036H4S (208/230V) TXV 36000 15.5 12.2 CH23-41 SLP98UH090XV60C 6513349SSB036H4S (208/230V) TXV 36000 15.5 12.5 CH23-41 SLP98UH110XV60C 6513352SSB036H4S (208/230V) TXV 35000 13 11 CH23-41 6512885SSB036H4S (208/230V) TXV 35600 15 12.5 CH23-51 EL180UH070E36B 6513365SSB036H4S (208/230V) TXV 35600 15 11.7 CH23-51 EL195UH045XE36B 6513355SSB036H4S (208/230V) TXV 35600 15 12.2 CH23-51 EL195UH070XE36B 6513359SSB036H4S (208/230V) TXV 35200 14.5 11 CH23-51 EL296UH045XE36B 6513821SSB036H4S (208/230V) TXV 35400 14.5 11.7 CH23-51 EL296UH070XE36B 6513823SSB036H4S (208/230V) TXV 35800 15.5 12.5 CH23-51 EL296UH110XV48C 6513361SSB036H4S (208/230V) TXV 36000 15.5 12 CH23-65 EL180UH070E36B 6513730SSB036H4S (208/230V) TXV 36000 15 11.7 CH23-65 EL195UH045XE36B 6513367SSB036H4S (208/230V) TXV 36000 15 12.2 CH23-65 EL195UH070XE36B 6513372SSB036H4S (208/230V) TXV 35600 14.5 11.7 CH23-65 EL296UH045XE36B 6513732SSB036H4S (208/230V) TXV 35800 15 11.7 CH23-65 EL296UH070XE36B 6512918SSB036H4S (208/230V) TXV 36200 15.5 12.5 CH23-65 EL296UH090XV36C 6513826SSB036H4S (208/230V) TXV 36000 15.5 12.5 CH23-65 EL296UH090XV48C 6512920SSB036H4S (208/230V) TXV 36600 16 12.5 CH23-65 EL296UH090XV60C 6512922SSB036H4S (208/230V) TXV 36400 16 12.5 CH23-65 EL296UH110XV60C 6512924SSB036H4S (208/230V) TXV 36600 15.1 12.5 CH23-65 SL280UH090V60C 6513378SSB036H4S (208/230V) TXV 36400 15.1 12.5 CH23-65 SL280UH090XV60C 6512928NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 14: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 14

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 36400 15.1 12.5 CH23-65 SL280UH110V60C 6513380SSB036H4S (208/230V) TXV 36600 15.1 12.5 CH23-65 SL280UH110XV60C 6512926SSB036H4S (208/230V) TXV 36200 15.5 12.5 CH23-65 SLP98UH090XV36C 6513384SSB036H4S (208/230V) TXV 36000 15.5 12.5 CH23-65 SLP98UH090XV48C 6513386SSB036H4S (208/230V) TXV 36600 15.5 12.5 CH23-65 SLP98UH090XV60C 6513129SSB036H4S (208/230V) TXV 36400 15.5 12.5 CH23-65 SLP98UH110XV60C 6513130SSB036H4S (208/230V) TXV 35400 13 11 CH23-65 6512882SSB036H4S (208/230V) TXV 36200 15 12 CH33-31 EL296UH045XV36B 6513132SSB036H4S (208/230V) TXV 34800 15 11.7 CH33-36 EL296UH045XV36B 6513140SSB036H4S (208/230V) TXV 34800 15 11.7 CH33-36 EL296UH070XV36B 6512930SSB036H4S (208/230V) TXV 35600 15 12.2 CH33-36 EL296UH090XV36C 6512932SSB036H4S (208/230V) TXV 35400 15.5 12.2 CH33-36 EL296UH090XV48C 6512934SSB036H4S (208/230V) TXV 36000 15.5 12.2 CH33-36 EL296UH090XV60C 6512936SSB036H4S (208/230V) TXV 35800 15.5 12.2 CH33-36 EL296UH110XV60C 6512976SSB036H4S (208/230V) TXV 35200 15 12 CH33-36 SL280UH070V36A 6512940SSB036H4S (208/230V) TXV 35200 15 12 CH33-36 SL280UH070XV36A 6512938SSB036H4S (208/230V) TXV 35000 15 12 CH33-36 SL280UH090V48B 6512978SSB036H4S (208/230V) TXV 36000 15.1 12.2 CH33-36 SL280UH090V60C 6512948SSB036H4S (208/230V) TXV 35000 15 12 CH33-36 SL280UH090XV48B 6512942SSB036H4S (208/230V) TXV 36000 15.1 12.2 CH33-36 SL280UH090XV60C 6512980SSB036H4S (208/230V) TXV 35800 15 12 CH33-36 SL280UH110V60C 6512950SSB036H4S (208/230V) TXV 35800 15.1 12 CH33-36 SL280UH110XV60C 6513028SSB036H4S (208/230V) TXV 34800 15 11.7 CH33-36 SLP98UH070XV36B 6512944SSB036H4S (208/230V) TXV 35600 15 12.2 CH33-36 SLP98UH090XV36C 6512952SSB036H4S (208/230V) TXV 35400 15 12.2 CH33-36 SLP98UH090XV48C 6512954SSB036H4S (208/230V) TXV 36000 15.5 12.2 CH33-36 SLP98UH090XV60C 6512903SSB036H4S (208/230V) TXV 35800 15.5 12.2 CH33-36 SLP98UH110XV60C 6512905SSB036H4S (208/230V) TXV 35400 15 11.7 CH33-36A EL180UH045E36A 6513030SSB036H4S (208/230V) TXV 34800 14.5 11.7 CH33-36A SL280UH070V36A 6605853SSB036H4S (208/230V) TXV 34800 14.5 11.7 CH33-36A SL280UH070XV36A 6605855SSB036H4S (208/230V) TXV 35400 15 11.7 CH33-36B EL180UH070XE36B 6513032SSB036H4S (208/230V) TXV 34600 14.5 11 CH33-36B EL195UH045XE36B 6513137SSB036H4S (208/230V) TXV 34800 14.5 11.7 CH33-36B EL195UH070XE36B 6513139SSB036H4S (208/230V) TXV 35200 14.5 11 CH33-36B EL296UH045XE36B 6513033SSB036H4S (208/230V) TXV 35200 15 11 CH33-36B EL296UH070XE36B 6513035SSB036H4S (208/230V) TXV 34400 13 11 CH33-36B 6512872SSB036H4S (208/230V) TXV 35600 15.5 12.2 CH33-36C EL296UH110XV48C 6512946SSB036H4S (208/230V) TXV 35000 13 11 CH33-36C 6512862SSB036H4S (208/230V) TXV 36000 15.5 12 CH33-42 EL180UH070E36B 6513039SSB036H4S (208/230V) TXV 35600 14.5 11.7 CH33-42 EL195UH045XE36B 6512957SSB036H4S (208/230V) TXV 35600 14.5 11.7 CH33-42 EL195UH070XE36B 6512907SSB036H4S (208/230V) TXV 35600 14.5 11.7 CH33-42 EL296UH045XE36B 6513042SSB036H4S (208/230V) TXV 35800 15 11.7 CH33-42 EL296UH045XV36B 6512909NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 15: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 15

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 35600 15 11.7 CH33-42 EL296UH070XE36B 6513043SSB036H4S (208/230V) TXV 35800 15 12 CH33-42 EL296UH070XV36B 6513045SSB036H4S (208/230V) TXV 36000 15.5 12.2 CH33-42 SL280UH090V36B 6512912SSB036H4S (208/230V) TXV 35800 15 12.2 CH33-42 SL280UH090V48B 6512914SSB036H4S (208/230V) TXV 36000 15 12.2 CH33-42 SL280UH090XV48B 6513037SSB036H4S (208/230V) TXV 35800 15 12 CH33-42 SLP98UH070XV36B 6512916SSB036H4S (208/230V) TXV 35400 13 11 CH33-42 6512860SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 EL180UH070E36B 6513091SSB036H4S (208/230V) TXV 37000 15 12 CH33-43 EL195UH045XE36B 6512958SSB036H4S (208/230V) TXV 37000 15 12.2 CH33-43 EL195UH070XE36B 6512960SSB036H4S (208/230V) TXV 37000 15 12 CH33-43 EL296UH045XE36B 6513094SSB036H4S (208/230V) TXV 37000 15.5 12.2 CH33-43 EL296UH045XV36B 6512963SSB036H4S (208/230V) TXV 37000 15.5 12.2 CH33-43 EL296UH070XE36B 6512982SSB036H4S (208/230V) TXV 37000 15.5 12.2 CH33-43 EL296UH070XV36B 6512984SSB036H4S (208/230V) TXV 36800 15.5 12.5 CH33-43 EL296UH090XV36C 6512986SSB036H4S (208/230V) TXV 36600 16 12.5 CH33-43 EL296UH090XV48C 6512988SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 EL296UH090XV60C 6512990SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 EL296UH110XV60C 6512992SSB036H4S (208/230V) TXV 37400 15.5 12.5 CH33-43 SL280UH090V36B 6512967SSB036H4S (208/230V) TXV 37200 15.5 12.5 CH33-43 SL280UH090V48B 6512969SSB036H4S (208/230V) TXV 37200 15.1 12.5 CH33-43 SL280UH090V60C 6512974SSB036H4S (208/230V) TXV 37200 15.5 12.5 CH33-43 SL280UH090XV48B 6512994SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 SL280UH090XV60C 6513087SSB036H4S (208/230V) TXV 37000 15.1 12.5 CH33-43 SL280UH110V60C 6513009SSB036H4S (208/230V) TXV 37000 15.1 12.5 CH33-43 SL280UH110XV60C 6513090SSB036H4S (208/230V) TXV 37000 15.5 12.2 CH33-43 SLP98UH070XV36B 6512970SSB036H4S (208/230V) TXV 36800 15.5 12.5 CH33-43 SLP98UH090XV36C 6513011SSB036H4S (208/230V) TXV 37000 16 12.5 CH33-43 SLP98UH090XV48C 6513014SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 SLP98UH090XV60C 6513016SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-43 SLP98UH110XV60C 6513017SSB036H4S (208/230V) TXV 36800 14 11.7 CH33-43B 6512861SSB036H4S (208/230V) TXV 36800 16 12.5 CH33-43C EL296UH110XV48C 6512973SSB036H4S (208/230V) TXV 36200 14 11.7 CH33-43C 6512863SSB036H4S (208/230V) TXV 36400 15.5 12.2 CH33-44/48 EL180UH070E36B 6513098SSB036H4S (208/230V) TXV 36400 15.5 12.2 CH33-44/48 EL180UH070XE36B 6513102SSB036H4S (208/230V) TXV 36200 14.5 11.7 CH33-44/48 EL195UH045XE36B 6513020SSB036H4S (208/230V) TXV 36200 15 11.7 CH33-44/48 EL195UH070XE36B 6513022SSB036H4S (208/230V) TXV 36200 15 11.7 CH33-44/48 EL296UH045XE36B 6513100SSB036H4S (208/230V) TXV 36200 15 12 CH33-44/48 EL296UH045XV36B 6513024SSB036H4S (208/230V) TXV 36200 15.5 12 CH33-44/48 EL296UH070XV36B 6513104SSB036H4S (208/230V) TXV 36800 15.5 12.5 CH33-44/48 SL280UH090V36B 6513069SSB036H4S (208/230V) TXV 36600 15.5 12.2 CH33-44/48 SL280UH090V36B 6513067SSB036H4S (208/230V) TXV 36400 15 12.2 CH33-44/48 SL280UH090V48B 6513072NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 16: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 16

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 36400 15.5 12.2 CH33-44/48 SL280UH090XV48B 6513096SSB036H4S (208/230V) TXV 36400 15.5 12.2 CH33-44/48 SLP98UH070XV36B 6512996SSB036H4S (208/230V) TXV 36000 14 11 CH33-44/48 6512869SSB036H4S (208/230V) TXV 36600 15.5 12.5 CH33-48 EL296UH090XV36C 6513261SSB036H4S (208/230V) TXV 36400 15.5 12.5 CH33-48 EL296UH090XV48C 6513263SSB036H4S (208/230V) TXV 37000 16 12.5 CH33-48 EL296UH090XV60C 6513265SSB036H4S (208/230V) TXV 36800 16 12.5 CH33-48 EL296UH110XV60C 6513267SSB036H4S (208/230V) TXV 37000 15.1 12.5 CH33-48 SL280UH090V60C 6513073SSB036H4S (208/230V) TXV 37000 15.1 12.5 CH33-48 SL280UH090XV60C 6513259SSB036H4S (208/230V) TXV 36800 15.1 12.2 CH33-48 SL280UH110V60C 6513075SSB036H4S (208/230V) TXV 36800 15.1 12.5 CH33-48 SL280UH110XV60C 6513106SSB036H4S (208/230V) TXV 36600 15.5 12.5 CH33-48 SLP98UH090XV36C 6513077SSB036H4S (208/230V) TXV 36800 16 12.5 CH33-48 SLP98UH090XV48C 6513079SSB036H4S (208/230V) TXV 37000 15.5 12.5 CH33-48 SLP98UH090XV60C 6513081SSB036H4S (208/230V) TXV 36800 15.5 12.5 CH33-48 SLP98UH110XV60C 6513083SSB036H4S (208/230V) TXV 36000 14 11 CH33-48 6512864SSB036H4S (208/230V) TXV 36600 16 12.5 CH33-48C EL296UH110XV48C 6512998SSB036H4S (208/230V) TXV 37000 16 12.5 CH33-50/60C EL296UH110XV48C 6513085SSB036H4S (208/230V) TXV 37400 16 12.5 CH33-62D EL296UH090XV60C 8341584SSB036H4S (208/230V) TXV 37200 16 12.5 CH33-62D EL296UH110XV60C 8341585SSB036H4S (208/230V) TXV 35600 15 11.7 CR33-30/36 EL180DF070E36B 6513313SSB036H4S (208/230V) TXV 35200 14.5 11 CR33-30/36 EL195DF045XE36B 6513144SSB036H4S (208/230V) TXV 35200 14.5 11 CR33-30/36 EL296DF045XE36B 6513311SSB036H4S (208/230V) TXV 35400 15.5 12 CR33-30/36 EL296DF045XV36B 7505733SSB036H4S (208/230V) TXV 35600 15 12 CR33-30/36 EL296DF070XV48B 7505713SSB036H4S (208/230V) TXV 35600 15 12 CR33-30/36 EL296DF090XV60C 6513308SSB036H4S (208/230V) TXV 35600 15 12 CR33-30/36 EL296DF110XV60C 6513306SSB036H4S (208/230V) TXV 35400 15 11.7 CR33-30/36 SL280DF070V36A 6513143SSB036H4S (208/230V) TXV 35600 15 12 CR33-30/36 SL280DF090V48B 6513181SSB036H4S (208/230V) TXV 35600 15 12 CR33-30/36 SL280DF090V48B 6513158SSB036H4S (208/230V) TXV 36000 15.1 12.2 CR33-30/36 SL280DF090V60C 6513148SSB036H4S (208/230V) TXV 35600 15.1 12.2 CR33-30/36 SL280DF110V60C 6513150SSB036H4S (208/230V) TXV 35200 15 12 CR33-30/36 SLP98DF070XV36B 6513276SSB036H4S (208/230V) TXV 35400 15 12 CR33-30/36 SLP98DF090XV36C 6513274SSB036H4S (208/230V) TXV 35400 15 12.2 CR33-30/36 SLP98DF090XV48C 6513273SSB036H4S (208/230V) TXV 35800 15 12 CR33-30/36 SLP98DF090XV60C 6513270SSB036H4S (208/230V) TXV 35800 15.5 12.2 CR33-30/36 SLP98DF110XV60C 6513268SSB036H4S (208/230V) TXV 35000 13 11 CR33-30/36 6512874SSB036H4S (208/230V) TXV 36200 15 12 CR33-48 EL180DF070E36B 6513332SSB036H4S (208/230V) TXV 36000 15 11.7 CR33-48 EL195DF045XE36B 6513182SSB036H4S (208/230V) TXV 36000 15 12.2 CR33-48 EL195DF070XE48B 6513184SSB036H4S (208/230V) TXV 35800 14.5 11.7 CR33-48 EL296DF045XE36B 6513334SSB036H4S (208/230V) TXV 35800 15.5 12 CR33-48 EL296DF045XV36B 7505732NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 17: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 17

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 35800 14.5 12.2 CR33-48 EL296DF070XE48B 6513338SSB036H4S (208/230V) TXV 36000 15 12 CR33-48 EL296DF070XV48B 7505712SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 EL296DF090XV60C 6513342SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 EL296DF110XV60C 6513346SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 SL280DF090V48B 6513001SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 SL280DF090V48B 6513003SSB036H4S (208/230V) TXV 36600 15.1 12.5 CR33-48 SL280DF090V60C 6513189SSB036H4S (208/230V) TXV 36200 15.1 12.5 CR33-48 SL280DF110V60C 6513190SSB036H4S (208/230V) TXV 35800 15.5 12.2 CR33-48 SLP98DF070XV36B 6513328SSB036H4S (208/230V) TXV 36000 15.5 12.2 CR33-48 SLP98DF090XV36C 6513324SSB036H4S (208/230V) TXV 36000 15.5 12.2 CR33-48 SLP98DF090XV48C 6513321SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 SLP98DF090XV60C 6513319SSB036H4S (208/230V) TXV 36200 15.5 12.2 CR33-48 SLP98DF110XV60C 6513316SSB036H4S (208/230V) TXV 35400 13 11 CR33-48 6512865SSB036H4S (208/230V) TXV 35000 14.5 11.7 CX35-30/36A EL180UH045XE36A 10247533SSB036H4S (208/230V) TXV 35000 15 11.7 CX35-30/36A SL280UH070V36A 10247534SSB036H4S (208/230V) TXV 35000 15 11.7 CX35-30/36A SL280UH070XV36A 10247535SSB036H4S (208/230V) TXV 35000 15 11.7 CX35-30/36B EL180UH070E36B 10247536SSB036H4S (208/230V) TXV 34800 14.5 11 CX35-30/36B EL195UH045XE36B 10247537SSB036H4S (208/230V) TXV 34800 14.5 11.7 CX35-30/36B EL195UH070XE36B 10247538SSB036H4S (208/230V) TXV 34800 14.5 11 CX35-30/36B EL296UH045XE36B 10247540SSB036H4S (208/230V) TXV 34800 15 11.7 CX35-30/36B EL296UH045XV36B 10247539SSB036H4S (208/230V) TXV 34800 14.5 11.7 CX35-30/36B EL296UH070XE36B 10247541SSB036H4S (208/230V) TXV 35000 15 11.7 CX35-30/36B EL296UH070XV36B 10247542SSB036H4S (208/230V) TXV 35200 15 12 CX35-30/36B SL280UH090V36B 10247543SSB036H4S (208/230V) TXV 35000 15 12 CX35-30/36B SL280UH090V48B 10247544SSB036H4S (208/230V) TXV 35200 15 12.2 CX35-30/36B SL280UH090XV48B 10247545SSB036H4S (208/230V) TXV 35000 15 11.7 CX35-30/36B SLP98UH070XV36B 10247546SSB036H4S (208/230V) TXV 34800 15 12 CX35-30/36C CBWMV-36C-090 10247547SSB036H4S (208/230V) TXV 35000 15 12 CX35-30/36C EL296UH090XV36C 10247548SSB036H4S (208/230V) TXV 34800 15 12 CX35-30/36C EL296UH090XV48C 10247549SSB036H4S (208/230V) TXV 35000 15 12.2 CX35-30/36C EL296UH110XV48C 10247550SSB036H4S (208/230V) TXV 35400 15 12.2 CX35-30/36C EL296UH110XV60C 10247551SSB036H4S (208/230V) TXV 35400 15 12 CX35-30/36C SL280UH090V60C 10247552SSB036H4S (208/230V) TXV 35400 15.1 12 CX35-30/36C SL280UH090XV60C 10247553SSB036H4S (208/230V) TXV 35200 15 12 CX35-30/36C SL280UH110V60C 10247554SSB036H4S (208/230V) TXV 35400 15 12 CX35-30/36C SL280UH110XV60C 10247555SSB036H4S (208/230V) TXV 35000 15 12 CX35-30/36C SLP98UH090XV36C 10247556SSB036H4S (208/230V) TXV 35200 15 12 CX35-30/36C SLP98UH090XV48C 10247557SSB036H4S (208/230V) TXV 35600 15 12 CX35-30/36C SLP98UH090XV60C 10247558SSB036H4S (208/230V) TXV 35400 15 12.2 CX35-30/36C SLP98UH110XV60C 10247559SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36A EL180UH045XE36A 10247560SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36A SL280UH070V36A 10247561NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 18: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 18

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36A SL280UH070XV36A 10247562SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36B EL180UH070XE36B 10247564SSB036H4S (208/230V) TXV 36200 15 11.7 CX35-36B EL195UH045XE36B 10247565SSB036H4S (208/230V) TXV 36200 15.5 12.2 CX35-36B EL195UH070XE36B 10247566SSB036H4S (208/230V) TXV 36000 15 11.7 CX35-36B EL296UH045XE36B 10247568SSB036H4S (208/230V) TXV 36200 15.5 12.2 CX35-36B EL296UH045XV36B 10247567SSB036H4S (208/230V) TXV 36200 15.5 12.2 CX35-36B EL296UH070XE36B 10247569SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36B EL296UH070XV36B 10247570SSB036H4S (208/230V) TXV 36600 15.5 12.5 CX35-36B SL280UH090V36B 10247571SSB036H4S (208/230V) TXV 36600 15.5 12.5 CX35-36B SL280UH090V48B 10247572SSB036H4S (208/230V) TXV 36600 15.5 12.5 CX35-36B SL280UH090XV48B 10247573SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-36B SLP98UH070XV36B 10247574SSB036H4S (208/230V) TXV 35800 14 11 CX35-36B 10247563SSB036H4S (208/230V) TXV 36600 15.5 12.2 CX35-48B EL180UH070E36B 10247575SSB036H4S (208/230V) TXV 36400 15 11.7 CX35-48B EL195UH045XE36B 10247576SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-48B EL195UH070XE36B 10247577SSB036H4S (208/230V) TXV 36400 15 11.7 CX35-48B EL296UH045XE36B 10247579SSB036H4S (208/230V) TXV 36600 15.5 12.2 CX35-48B EL296UH045XV36B 10247578SSB036H4S (208/230V) TXV 36400 15.5 12.2 CX35-48B EL296UH070XE36B 10247580SSB036H4S (208/230V) TXV 36600 15.5 12.2 CX35-48B EL296UH070XV36B 10247581SSB036H4S (208/230V) TXV 37000 16 12.5 CX35-48B SL280UH090V36B 10247582SSB036H4S (208/230V) TXV 36000 16 12.5 CX35-48B SL280UH090V48B 10247583SSB036H4S (208/230V) TXV 36000 16 12.5 CX35-48B SL280UH090XV48B 10247584SSB036H4S (208/230V) TXV 36000 15.5 12.2 CX35-48B SLP98UH070XV36B 10247585SSB036H4S (208/230V) TXV 36600 15.5 12.5 CX35-48C CBWMV-36C-090 10247587SSB036H4S (208/230V) TXV 37000 16 12.5 CX35-48C CBWMV-60C-100 10247588SSB036H4S (208/230V) TXV 36600 15.5 12.5 CX35-48C EL296UH090XV36C 10247589SSB036H4S (208/230V) TXV 36400 15.5 12.5 CX35-48C EL296UH090XV48C 10247590SSB036H4S (208/230V) TXV 37200 16 12.5 CX35-48C EL296UH090XV60C 10247591SSB036H4S (208/230V) TXV 36600 16 12.5 CX35-48C EL296UH110XV48C 10247592SSB036H4S (208/230V) TXV 37000 16 12.5 CX35-48C EL296UH110XV60C 10247593SSB036H4S (208/230V) TXV 37000 15.1 12.5 CX35-48C SL280UH090V60C 10247594SSB036H4S (208/230V) TXV 37000 15.1 12.5 CX35-48C SL280UH090XV60C 10247595SSB036H4S (208/230V) TXV 36800 15.1 12.5 CX35-48C SL280UH110V60C 10247596SSB036H4S (208/230V) TXV 37000 15.1 12.5 CX35-48C SL280UH110XV60C 10247597SSB036H4S (208/230V) TXV 36800 15.5 12.5 CX35-48C SLP98UH090XV36C 10247598SSB036H4S (208/230V) TXV 36800 16 12.5 CX35-48C SLP98UH090XV48C 10247599SSB036H4S (208/230V) TXV 37200 16 12.5 CX35-48C SLP98UH090XV60C 10247600SSB036H4S (208/230V) TXV 37000 15.5 12.5 CX35-48C SLP98UH110XV60C 10247601SSB036H4S (208/230V) TXV 36200 14 11.7 CX35-48C 10247586SSB036H4S (208/230V) TXV 37000 15.5 12.5 CX35-49C EL296UH090XV36C 10247603SSB036H4S (208/230V) TXV 35800 16 12.5 CX35-49C EL296UH090XV48C 10247604SSB036H4S (208/230V) TXV 37600 16 12.5 CX35-49C EL296UH090XV60C 10250505NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 19: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 19

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (208/230V) TXV 37400 16 12.5 CX35-49C EL296UH110XV60C 10247605SSB036H4S (208/230V) TXV 37600 16 12.5 CX35-49C SL280UH090V60C 10247606SSB036H4S (208/230V) TXV 37600 16 12.5 CX35-49C SL280UH090XV60C 10247607SSB036H4S (208/230V) TXV 37200 15.1 12.5 CX35-49C SL280UH110V60C 10247608SSB036H4S (208/230V) TXV 37400 15.1 12.5 CX35-49C SL280UH110XV60C 10247609SSB036H4S (208/230V) TXV 37000 16 12.5 CX35-49C SLP98UH090XV36C 10247610SSB036H4S (208/230V) TXV 37400 16 12.5 CX35-49C SLP98UH090XV48C 10247611SSB036H4S (208/230V) TXV 37600 16 12.5 CX35-49C SLP98UH090XV60C 10247612SSB036H4S (208/230V) TXV 37400 14 11.7 CX35-49C SLP98UH110XV60C 10247613SSB036H4S (208/230V) TXV 36400 14 11.7 CX35-49C 10247602SSB036H4S (208/230V) TXV 36400 16 12.5 CX35-50/60C EL296UH110XV48C 10247614SSB036H4S (208/230V) TXV 36800 15.5 12.5 CX38-43B SL280UH090V36B 10555669SSB036H4S (460V) TXV 35000 14.5 11.7 C35-30/36A EL180UH045E36A 10247615SSB036H4S (460V) TXV 35000 15 11.7 C35-30/36A SL280UH070V36A 10247616SSB036H4S (460V) TXV 35000 15 11.7 C35-30/36A SL280UH070XV36A 10247617SSB036H4S (460V) TXV 35000 15 11.7 C35-30/36B EL180UH070E36B 10247618SSB036H4S (460V) TXV 34800 14.5 11.7 C35-30/36B EL195UH045XE36B 10247620SSB036H4S (460V) TXV 34800 14.5 11 C35-30/36B EL195UH070XE36B 10247619SSB036H4S (460V) TXV 34800 14.5 11 C35-30/36B EL296UH045XE36B 10247622SSB036H4S (460V) TXV 34800 15 11.7 C35-30/36B EL296UH045XV36B 10247621SSB036H4S (460V) TXV 34800 14.5 11.7 C35-30/36B EL296UH070XE36B 10247623SSB036H4S (460V) TXV 35200 15 12 C35-30/36B SL280UH090V36B 10247624SSB036H4S (460V) TXV 35000 15 12 C35-30/36B SL280UH090V48B 10247625SSB036H4S (460V) TXV 35200 15 12.2 C35-30/36B SL280UH090XV48B 10247626SSB036H4S (460V) TXV 35000 15 11.7 C35-30/36B SLP98UH070XV36B 10247627SSB036H4S (460V) TXV 34800 15 12 C35-30/36C CBWMV-036C-090 10247628SSB036H4S (460V) TXV 34800 15 12 C35-30/36C EL296UH090XV48C 10247629SSB036H4S (460V) TXV 35000 15 12 C35-30/36C EL296UH110XV48C 10247630SSB036H4S (460V) TXV 35400 15 12.2 C35-30/36C EL296UH110XV60C 10247631SSB036H4S (460V) TXV 35400 15 12 C35-30/36C SL280UH090V60C 10247632SSB036H4S (460V) TXV 35400 15.1 12 C35-30/36C SL280UH090XV60C 10247633SSB036H4S (460V) TXV 35200 15 12 C35-30/36C SL280UH110V60C 10247634SSB036H4S (460V) TXV 35400 15 12 C35-30/36C SL280UH110XV60C 10247635SSB036H4S (460V) TXV 35000 15 12 C35-30/36C SLP98UH090XV36C 10247636SSB036H4S (460V) TXV 35200 15 12 C35-30/36C SLP98UH090XV48C 10247637SSB036H4S (460V) TXV 35600 15 12 C35-30/36C SLP98UH090XV608C 10247638SSB036H4S (460V) TXV 35400 15 12.2 C35-30/36C SLP98UH110XV60C 10247639SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36A EL180UH045E36A 10247640SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36A EL180UH045XE36A 10247643SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36A SL280UH070V36A 10247641SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36A SL280UH070XV36A 10247642SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36B EL180UH070E36B 10247644SSB036H4S (460V) TXV 36200 15 11.7 C35-36B EL195UH045XE36B 10247645NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 20: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 20

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 36200 15.5 12.2 C35-36B EL195UH070XE36B 10247646SSB036H4S (460V) TXV 36200 15 11.7 C35-36B EL296UH045XE36B 10247648SSB036H4S (460V) TXV 36200 15.5 12.2 C35-36B EL296UH045XV36B 10247647SSB036H4S (460V) TXV 36200 15.5 12.2 C35-36B EL296UH070XE36B 10247649SSB036H4S (460V) TXV 36600 15.5 12.5 C35-36B SL280UH090V36B 10247650SSB036H4S (460V) TXV 36600 15.5 12.5 C35-36B SL280UH090V48B 10247651SSB036H4S (460V) TXV 36600 15.5 12.5 C35-36B SL280UH090XV48B 10247652SSB036H4S (460V) TXV 36400 15.5 12.2 C35-36B SLP98UH070XV36B 10247653SSB036H4S (460V) TXV 35800 14 11 C35-36B 10250506SSB036H4S (460V) TXV 36600 15.5 12.2 C35-48B EL180UH070E36B 10247654SSB036H4S (460V) TXV 36400 15 11.7 C35-48B EL195UH045XE36B 10247655SSB036H4S (460V) TXV 36400 15.5 12.2 C35-48B EL195UH070XE36B 10247656SSB036H4S (460V) TXV 36400 15 11.7 C35-48B EL296UH045XE36B 10247658SSB036H4S (460V) TXV 36600 15.5 12.2 C35-48B EL296UH045XV36B 10247657SSB036H4S (460V) TXV 36400 15.5 12.2 C35-48B EL296UH070XE36B 10247659SSB036H4S (460V) TXV 36600 15.5 12.2 C35-48B EL296UH070XV36B 10247660SSB036H4S (460V) TXV 37000 16 12.5 C35-48B SL280UH090V36B 10247661SSB036H4S (460V) TXV 36000 16 12.5 C35-48B SL280UH090V48B 10247662SSB036H4S (460V) TXV 36000 16 12.5 C35-48B SL280UH090XV48B 10247663SSB036H4S (460V) TXV 36600 15.5 12.2 C35-48B SLP98UH070XV36B 10247664SSB036H4S (460V) TXV 36600 15.5 12.5 C35-48C CBWMV-36C-090 10247665SSB036H4S (460V) TXV 37000 16 12.5 C35-48C CBWMV-60C-100 10247666SSB036H4S (460V) TXV 36600 16 12.5 C35-48C EL296UH110XV48C 10247667SSB036H4S (460V) TXV 36600 15.1 12 C35-48C SL280UH090V60C 10247668SSB036H4S (460V) TXV 37000 15.1 12.5 C35-48C SL280UH090XV60C 10247669SSB036H4S (460V) TXV 36800 15.1 12.5 C35-48C SL280UH110V60C 10247670SSB036H4S (460V) TXV 36800 15.1 12.5 C35-48C SL280UH110XV60C 10247671SSB036H4S (460V) TXV 36800 15.5 12.5 C35-48C SLP98UH090XV36C 10247672SSB036H4S (460V) TXV 36800 16 12.5 C35-48C SLP98UH090XV48C 10247673SSB036H4S (460V) TXV 37200 16 12.5 C35-48C SLP98UH090XV60C 10247674SSB036H4S (460V) TXV 37000 15.5 12.5 C35-48C SLP98UH110XV60C 10247675SSB036H4S (460V) TXV 36200 14 11.7 C35-48C 10250507SSB036H4S (460V) TXV 37600 16 12.5 C35-49C SL280UH090V60C 10247676SSB036H4S (460V) TXV 37600 16 12.5 C35-49C SL280UH090XV60C 10247677SSB036H4S (460V) TXV 37200 15.1 12.5 C35-49C SL280UH110V60C 10247678SSB036H4S (460V) TXV 37400 15.1 12.5 C35-49C SL280UH110XV60C 10247679SSB036H4S (460V) TXV 37000 16 12.5 C35-49C SLP98UH090XV36C 10247680SSB036H4S (460V) TXV 37400 16 12.5 C35-49C SLP98UH090XV48C 10247681SSB036H4S (460V) TXV 37600 16 12.5 C35-49C SLP98UH090XV60C 10247682SSB036H4S (460V) TXV 37400 16 12.5 C35-49C SLP98UH110XV60C 10247683SSB036H4S (460V) TXV 36400 14 11.7 C35-49C 10250508SSB036H4S (460V) TXV 36400 16 12.5 C35-50/60C EL296UH110XV48C 10247684SSB036H4S (460V) TXV 36000 15 12.2 CBA27UHE-036 10259518NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 21: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 21

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 36000 16 12.5 CBA27UHE-042 10259519SSB036H4S (460V) TXV 34800 13 11 CBX25UH-030 6513805SSB036H4S (460V) TXV 35800 15 12.2 CBX27UH-036 6513183SSB036H4S (460V) TXV 37000 16 12.5 CBX27UH-042 6513185SSB036H4S (460V) TXV 35200 14.5 11.7 CBX32M-030 6513187SSB036H4S (460V) TXV 35400 14.5 11.7 CBX32M-036 6513188SSB036H4S (460V) TXV 35600 14.5 11.7 CBX32M-042 6513191SSB036H4S (460V) TXV 35600 15 12 CBX32MV-024/030 6513211SSB036H4S (460V) TXV 36000 15.5 12 CBX32MV-036 6513213SSB036H4S (460V) TXV 37000 16 12.5 CBX32MV-048 6513414SSB036H4S (460V) TXV 35400 15 11.7 CBX40UHV-030 6513810SSB036H4S (460V) TXV 35200 15 12 CBX40UHV-036 6513812SSB036H4S (460V) TXV 36600 15.5 12.2 CBX40UHV-042 6513814SSB036H4S (460V) TXV 36600 15 12.5 CBX40UHV-048 6513816SSB036H4S (460V) TXV 35600 15 12 CH23-41 EL180UH070E36B 6513820SSB036H4S (460V) TXV 35600 14.5 11.7 CH23-41 EL195UH045XE36B 6513417SSB036H4S (460V) TXV 35400 15 12 CH23-41 EL195UH070XE36B 6513420SSB036H4S (460V) TXV 35200 14.5 11 CH23-41 EL296UH045XE36B 6513822SSB036H4S (460V) TXV 35200 14.5 11 CH23-41 EL296UH070XE36B 6513824SSB036H4S (460V) TXV 35400 15.5 12 CH23-41 EL296UH070XV36B 6513818SSB036H4S (460V) TXV 35600 15.5 12.2 CH23-41 EL296UH090XV36C 6513827SSB036H4S (460V) TXV 35400 15.5 12.2 CH23-41 EL296UH090XV48C 6513828SSB036H4S (460V) TXV 36000 15.5 12.2 CH23-41 EL296UH090XV60C 6513829SSB036H4S (460V) TXV 35600 15.5 12.5 CH23-41 EL296UH110XV48C 6513424SSB036H4S (460V) TXV 36000 15.5 12.5 CH23-41 EL296UH110XV60C 6513830SSB036H4S (460V) TXV 35400 15.5 12.5 CH23-41 SL280UH090V36B 6513217SSB036H4S (460V) TXV 35600 15 12.5 CH23-41 SL280UH090V48B 6513219SSB036H4S (460V) TXV 36000 15.1 12.5 CH23-41 SL280UH090V60C 6513221SSB036H4S (460V) TXV 35600 15.5 12.5 CH23-41 SL280UH090XV48B 6513831SSB036H4S (460V) TXV 36000 15.1 12.5 CH23-41 SL280UH090XV60C 6513832SSB036H4S (460V) TXV 35800 15.1 12.2 CH23-41 SL280UH110V60C 6513223SSB036H4S (460V) TXV 35800 15.1 12.2 CH23-41 SL280UH110XV60C 6513833SSB036H4S (460V) TXV 35400 15.5 12 CH23-41 SLP98UH070XV36B 6513225SSB036H4S (460V) TXV 35600 15.5 12.2 CH23-41 SLP98UH090XV36C 6513227SSB036H4S (460V) TXV 35400 15.5 12.2 CH23-41 SLP98UH090XV48C 6513229SSB036H4S (460V) TXV 36000 15.5 12.2 CH23-41 SLP98UH090XV60C 6513371SSB036H4S (460V) TXV 36000 15.5 12.5 CH23-41 SLP98UH110XV60C 6513376SSB036H4S (460V) TXV 35000 13 11 CH23-41 6512896SSB036H4S (460V) TXV 35600 15 12.5 CH23-51 EL180UH070E36B 6513389SSB036H4S (460V) TXV 35600 15 11.7 CH23-51 EL195UH045XE36B 6513379SSB036H4S (460V) TXV 35600 15 12.2 CH23-51 EL195UH070XE36B 6513382SSB036H4S (460V) TXV 35200 14.5 11 CH23-51 EL296UH045XE36B 6513834SSB036H4S (460V) TXV 35400 14.5 11.7 CH23-51 EL296UH070XE36B 6513835NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 22: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 22

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 35800 15.5 12.5 CH23-51 EL296UH110XV48C 6513385SSB036H4S (460V) TXV 36000 15.5 12 CH23-65 EL180UH070E36B 6513747SSB036H4S (460V) TXV 36000 15 11.7 CH23-65 EL195UH045XE36B 6513391SSB036H4S (460V) TXV 36000 15 12.2 CH23-65 EL195UH070XE36B 6513395SSB036H4S (460V) TXV 35600 14.5 11.7 CH23-65 EL296UH045XE36B 6513748SSB036H4S (460V) TXV 35800 15 11.7 CH23-65 EL296UH070XE36B 6512931SSB036H4S (460V) TXV 36200 15.5 12.5 CH23-65 EL296UH090XV36C 6513837SSB036H4S (460V) TXV 36000 15.5 12.5 CH23-65 EL296UH090XV48C 6512933SSB036H4S (460V) TXV 36600 16 12.5 CH23-65 EL296UH090XV60C 6512935SSB036H4S (460V) TXV 36400 16 12.5 CH23-65 EL296UH110XV60C 6512937SSB036H4S (460V) TXV 36600 15.1 12.5 CH23-65 SL280UH090V60C 6513402SSB036H4S (460V) TXV 36400 15.1 12.5 CH23-65 SL280UH090XV60C 6512941SSB036H4S (460V) TXV 36400 15.1 12.5 CH23-65 SL280UH110V60C 6513404SSB036H4S (460V) TXV 36600 15.1 12.5 CH23-65 SL280UH110XV60C 6512939SSB036H4S (460V) TXV 36200 15.5 12.5 CH23-65 SLP98UH090XV36C 6513408SSB036H4S (460V) TXV 36000 15.5 12.5 CH23-65 SLP98UH090XV48C 6513411SSB036H4S (460V) TXV 36600 15.5 12.5 CH23-65 SLP98UH090XV60C 6513141SSB036H4S (460V) TXV 36400 15.5 12.5 CH23-65 SLP98UH110XV60C 6513142SSB036H4S (460V) TXV 35400 13 11 CH23-65 6512894SSB036H4S (460V) TXV 36200 15 12 CH33-31 EL296UH045XV36B 6513145SSB036H4S (460V) TXV 34800 15 11.7 CH33-36 EL296UH045XV36B 6513153SSB036H4S (460V) TXV 34800 15 11.7 CH33-36 EL296UH070XV36B 6512943SSB036H4S (460V) TXV 35600 15 12.2 CH33-36 EL296UH090XV36C 6512945SSB036H4S (460V) TXV 35400 15.5 12.2 CH33-36 EL296UH090XV48C 6512947SSB036H4S (460V) TXV 36000 15.5 12.2 CH33-36 EL296UH090XV60C 6512949SSB036H4S (460V) TXV 35800 15.5 12.2 CH33-36 EL296UH110XV60C 6512989SSB036H4S (460V) TXV 35200 15 12 CH33-36 SL280UH070V36A 6512953SSB036H4S (460V) TXV 35200 15 12 CH33-36 SL280UH070XV36A 6512951SSB036H4S (460V) TXV 35000 15 12 CH33-36 SL280UH090V48B 6512991SSB036H4S (460V) TXV 36000 15.1 12.2 CH33-36 SL280UH090V60C 6512961SSB036H4S (460V) TXV 35000 15 12 CH33-36 SL280UH090XV48B 6512955SSB036H4S (460V) TXV 36000 15.1 12.2 CH33-36 SL280UH090XV60C 6512993SSB036H4S (460V) TXV 35800 15 12 CH33-36 SL280UH110V60C 6512962SSB036H4S (460V) TXV 35800 15.1 12 CH33-36 SL280UH110XV60C 6513041SSB036H4S (460V) TXV 34800 15 11.7 CH33-36 SLP98UH070XV36B 6512956SSB036H4S (460V) TXV 35600 15 12.2 CH33-36 SLP98UH090XV36C 6512964SSB036H4S (460V) TXV 35400 15 12.2 CH33-36 SLP98UH090XV48C 6512966SSB036H4S (460V) TXV 36000 15.5 12.2 CH33-36 SLP98UH090XV60C 6512915SSB036H4S (460V) TXV 35800 15.5 12.2 CH33-36 SLP98UH110XV60C 6512917SSB036H4S (460V) TXV 35400 15 11.7 CH33-36A EL180UH045E36A 6513044SSB036H4S (460V) TXV 34800 14.5 11.7 CH33-36A SL280UH070V36A 6605857SSB036H4S (460V) TXV 34800 14.5 11.7 CH33-36A SL280UH070XV36A 6605859SSB036H4S (460V) TXV 35400 15 11.7 CH33-36B EL180UH070XE36B 6513046NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 23: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 23

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 34600 14.5 11 CH33-36B EL195UH045XE36B 6513149SSB036H4S (460V) TXV 34800 14.5 11.7 CH33-36B EL195UH070XE36B 6513151SSB036H4S (460V) TXV 35200 14.5 11 CH33-36B EL296UH045XE36B 6513047SSB036H4S (460V) TXV 35200 15 11 CH33-36B EL296UH070XE36B 6513050SSB036H4S (460V) TXV 34400 13 11 CH33-36B 6512884SSB036H4S (460V) TXV 35600 15.5 12.2 CH33-36C EL296UH110XV48C 6512959SSB036H4S (460V) TXV 35000 13 11 CH33-36C 6512870SSB036H4S (460V) TXV 36000 15.5 12 CH33-42 EL180UH070E36B 6513054SSB036H4S (460V) TXV 35600 14.5 11.7 CH33-42 EL195UH045XE36B 6512968SSB036H4S (460V) TXV 35600 14.5 11.7 CH33-42 EL195UH070XE36B 6512919SSB036H4S (460V) TXV 35600 14.5 11.7 CH33-42 EL296UH045XE36B 6513056SSB036H4S (460V) TXV 35800 15 11.7 CH33-42 EL296UH045XV36B 6512921SSB036H4S (460V) TXV 35600 15 11.7 CH33-42 EL296UH070XE36B 6513058SSB036H4S (460V) TXV 35800 15 12 CH33-42 EL296UH070XV36B 6513059SSB036H4S (460V) TXV 36000 15.5 12.2 CH33-42 SL280UH090V36B 6512925SSB036H4S (460V) TXV 35800 15 12.2 CH33-42 SL280UH090V48B 6512927SSB036H4S (460V) TXV 36000 15 12.2 CH33-42 SL280UH090XV48B 6513052SSB036H4S (460V) TXV 35800 15 12 CH33-42 SLP98UH070XV36B 6512929SSB036H4S (460V) TXV 35400 13 11 CH33-42 6512866SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 EL180UH070E36B 6513105SSB036H4S (460V) TXV 37000 15 12 CH33-43 EL195UH045XE36B 6512971SSB036H4S (460V) TXV 37000 15 12.2 CH33-43 EL195UH070XE36B 6512972SSB036H4S (460V) TXV 37000 15 12 CH33-43 EL296UH045XE36B 6513107SSB036H4S (460V) TXV 37000 15.5 12.2 CH33-43 EL296UH045XV36B 6512975SSB036H4S (460V) TXV 37000 15.5 12.2 CH33-43 EL296UH070XE36B 6512995SSB036H4S (460V) TXV 37000 15.5 12.2 CH33-43 EL296UH070XV36B 6512997SSB036H4S (460V) TXV 36800 15.5 12.5 CH33-43 EL296UH090XV36C 6513000SSB036H4S (460V) TXV 36600 16 12.5 CH33-43 EL296UH090XV48C 6513002SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 EL296UH090XV60C 6513004SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 EL296UH110XV60C 6513005SSB036H4S (460V) TXV 37400 15.5 12.5 CH33-43 SL280UH090V36B 6512979SSB036H4S (460V) TXV 37200 15.5 12.5 CH33-43 SL280UH090V48B 6512981SSB036H4S (460V) TXV 37200 15.1 12.5 CH33-43 SL280UH090V60C 6512987SSB036H4S (460V) TXV 37200 15.5 12.5 CH33-43 SL280UH090XV48B 6513008SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 SL280UH090XV60C 6513101SSB036H4S (460V) TXV 37000 15.1 12.5 CH33-43 SL280UH110V60C 6513023SSB036H4S (460V) TXV 37000 15.1 12.5 CH33-43 SL280UH110XV60C 6513103SSB036H4S (460V) TXV 37000 15.5 12.2 CH33-43 SLP98UH070XV36B 6512983SSB036H4S (460V) TXV 36800 15.5 12.5 CH33-43 SLP98UH090XV36C 6513025SSB036H4S (460V) TXV 37000 16 12.5 CH33-43 SLP98UH090XV48C 6513027SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 SLP98UH090XV60C 6513029SSB036H4S (460V) TXV 37200 16 12.5 CH33-43 SLP98UH110XV60C 6513031SSB036H4S (460V) TXV 36800 14 11.7 CH33-43B 6512868NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 24: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 24

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 36800 16 12.5 CH33-43C EL296UH110XV48C 6512985SSB036H4S (460V) TXV 36200 14 11.7 CH33-43C 6512873SSB036H4S (460V) TXV 36400 15.5 12.2 CH33-44/48 EL180UH070E36B 6513111SSB036H4S (460V) TXV 36400 15.5 12.2 CH33-44/48 EL180UH070XE36B 6513114SSB036H4S (460V) TXV 36200 14.5 11.7 CH33-44/48 EL195UH045XE36B 6513034SSB036H4S (460V) TXV 36200 15 11.7 CH33-44/48 EL195UH070XE36B 6513036SSB036H4S (460V) TXV 36200 15 11.7 CH33-44/48 EL296UH045XE36B 6513113SSB036H4S (460V) TXV 36200 15 12 CH33-44/48 EL296UH045XV36B 6513038SSB036H4S (460V) TXV 36200 15.5 12 CH33-44/48 EL296UH070XV36B 6513117SSB036H4S (460V) TXV 36800 15.5 12.5 CH33-44/48 SL280UH090V36B 6513084SSB036H4S (460V) TXV 36600 15.5 12.2 CH33-44/48 SL280UH090V36B 6513082SSB036H4S (460V) TXV 36400 15 12.2 CH33-44/48 SL280UH090V48B 6513086SSB036H4S (460V) TXV 36400 15.5 12.2 CH33-44/48 SL280UH090XV48B 6513109SSB036H4S (460V) TXV 36400 15.5 12.2 CH33-44/48 SLP98UH070XV36B 6513010SSB036H4S (460V) TXV 36000 14 11 CH33-44/48 6512881SSB036H4S (460V) TXV 36600 15.5 12.5 CH33-48 EL296UH090XV36C 6513272SSB036H4S (460V) TXV 36400 15.5 12.5 CH33-48 EL296UH090XV48C 6513275SSB036H4S (460V) TXV 37000 16 12.5 CH33-48 EL296UH090XV60C 6513277SSB036H4S (460V) TXV 36800 16 12.5 CH33-48 EL296UH110XV60C 6513279SSB036H4S (460V) TXV 37000 15.1 12.5 CH33-48 SL280UH090V60C 6513088SSB036H4S (460V) TXV 37000 15.1 12.5 CH33-48 SL280UH090XV60C 6513271SSB036H4S (460V) TXV 36800 15.1 12.2 CH33-48 SL280UH110V60C 6513089SSB036H4S (460V) TXV 36800 15.1 12.5 CH33-48 SL280UH110XV60C 6513119SSB036H4S (460V) TXV 36600 15.5 12.5 CH33-48 SLP98UH090XV36C 6513092SSB036H4S (460V) TXV 36800 16 12.5 CH33-48 SLP98UH090XV48C 6513093SSB036H4S (460V) TXV 37000 15.5 12.5 CH33-48 SLP98UH090XV60C 6513095SSB036H4S (460V) TXV 36800 15.5 12.5 CH33-48 SLP98UH110XV60C 6513097SSB036H4S (460V) TXV 36000 14 11 CH33-48 6512875SSB036H4S (460V) TXV 36600 16 12.5 CH33-48C EL296UH110XV48C 6513012SSB036H4S (460V) TXV 37000 16 12.5 CH33-50/60C EL296UH110XV48C 6513099SSB036H4S (460V) TXV 37400 16 12.5 CH33-62D EL296UH090XV60C 8341586SSB036H4S (460V) TXV 37200 16 12.5 CH33-62D EL296UH110XV60C 8341587SSB036H4S (460V) TXV 35600 15 11.7 CR33-30/36 EL180DF070E36B 6513336SSB036H4S (460V) TXV 35200 14.5 11 CR33-30/36 EL195DF045XE36B 6513157SSB036H4S (460V) TXV 35200 14.5 11 CR33-30/36 EL296DF045XE36B 6513333SSB036H4S (460V) TXV 35400 15.5 12 CR33-30/36 EL296DF045XV36B 7505735SSB036H4S (460V) TXV 35600 15 12 CR33-30/36 EL296DF070XV48B 7505715SSB036H4S (460V) TXV 35600 15 12 CR33-30/36 EL296DF090XV60C 6513329SSB036H4S (460V) TXV 35600 15 12 CR33-30/36 EL296DF110XV60C 6513325SSB036H4S (460V) TXV 35400 15 11.7 CR33-30/36 SL280DF070V36A 6513155SSB036H4S (460V) TXV 35600 15 12 CR33-30/36 SL280DF090V48B 6513193SSB036H4S (460V) TXV 35600 15 12 CR33-30/36 SL280DF090V48B 6513171SSB036H4S (460V) TXV 36000 15.1 12.2 CR33-30/36 SL280DF090V60C 6513161NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 25: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 25

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 35600 15.1 12.2 CR33-30/36 SL280DF110V60C 6513163SSB036H4S (460V) TXV 35200 15 12 CR33-30/36 SLP98DF070XV36B 6513291SSB036H4S (460V) TXV 35400 15 12 CR33-30/36 SLP98DF090XV36C 6513288SSB036H4S (460V) TXV 35400 15 12.2 CR33-30/36 SLP98DF090XV48C 6513285SSB036H4S (460V) TXV 35800 15 12 CR33-30/36 SLP98DF090XV60C 6513283SSB036H4S (460V) TXV 35800 15.5 12.2 CR33-30/36 SLP98DF110XV60C 6513281SSB036H4S (460V) TXV 35000 13 11 CR33-30/36 6512886SSB036H4S (460V) TXV 36200 15 12 CR33-48 EL180DF070E36B 6513357SSB036H4S (460V) TXV 36000 15 11.7 CR33-48 EL195DF045XE36B 6513195SSB036H4S (460V) TXV 36000 15 12.2 CR33-48 EL195DF070XE48B 6513196SSB036H4S (460V) TXV 35800 14.5 11.7 CR33-48 EL296DF045XE36B 6513360SSB036H4S (460V) TXV 35800 15.5 12 CR33-48 EL296DF045XV36B 7505734SSB036H4S (460V) TXV 35800 14.5 12.2 CR33-48 EL296DF070XE48B 6513362SSB036H4S (460V) TXV 36000 15 12 CR33-48 EL296DF070XV48B 7505714SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 EL296DF090XV60C 6513364SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 EL296DF110XV60C 6513368SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 SL280DF090V48B 6513018SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 SL280DF090V48B 6513015SSB036H4S (460V) TXV 36600 15.1 12.5 CR33-48 SL280DF090V60C 6513200SSB036H4S (460V) TXV 36200 15.1 12.5 CR33-48 SL280DF110V60C 6513203SSB036H4S (460V) TXV 35800 15.5 12.2 CR33-48 SLP98DF070XV36B 6513353SSB036H4S (460V) TXV 36000 15.5 12.2 CR33-48 SLP98DF090XV36C 6513350SSB036H4S (460V) TXV 36000 15.5 12.2 CR33-48 SLP98DF090XV48C 6513347SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 SLP98DF090XV60C 6513343SSB036H4S (460V) TXV 36200 15.5 12.2 CR33-48 SLP98DF110XV60C 6513339SSB036H4S (460V) TXV 35400 13 11 CR33-48 6512877SSB036H4S (460V) TXV 35000 14.5 11.7 CX35-30/36A EL180UH045XE36A 10247685SSB036H4S (460V) TXV 35000 15 11.7 CX35-30/36A SL280UH070V36A 10247686SSB036H4S (460V) TXV 35000 15 11.7 CX35-30/36A SL280UH070XV36A 10247687SSB036H4S (460V) TXV 35000 15 11.7 CX35-30/36B EL180UH070E36B 10247688SSB036H4S (460V) TXV 34800 14.5 11 CX35-30/36B EL195UH045XE36B 10247689SSB036H4S (460V) TXV 34800 14.5 11.7 CX35-30/36B EL195UH070XE36B 10247690SSB036H4S (460V) TXV 34800 14.5 11 CX35-30/36B EL296UH045XE36B 10247692SSB036H4S (460V) TXV 34800 15 11.7 CX35-30/36B EL296UH045XV36B 10247691SSB036H4S (460V) TXV 34800 14.5 11.7 CX35-30/36B EL296UH070XE36B 10247693SSB036H4S (460V) TXV 35000 15 11.7 CX35-30/36B EL296UH070XV36B 10247694SSB036H4S (460V) TXV 35200 15 12 CX35-30/36B SL280UH090V36B 10247695SSB036H4S (460V) TXV 35000 15 12 CX35-30/36B SL280UH090V48B 10247696SSB036H4S (460V) TXV 35200 15 12.2 CX35-30/36B SL280UH090XV48B 10247697SSB036H4S (460V) TXV 35000 15 11.7 CX35-30/36B SLP98UH070XV36B 10247698SSB036H4S (460V) TXV 34800 15 12 CX35-30/36C CBWMV-36C-090 10247699SSB036H4S (460V) TXV 35000 15 12 CX35-30/36C EL296UH090XV36C 10247700SSB036H4S (460V) TXV 34800 15 12 CX35-30/36C EL296UH090XV48C 10247701NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 26: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 26

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 35000 15 12.2 CX35-30/36C EL296UH110XV48C 10247702SSB036H4S (460V) TXV 35400 15 12.2 CX35-30/36C EL296UH110XV60C 10247703SSB036H4S (460V) TXV 35400 15 12 CX35-30/36C SL280UH090V60C 10247704SSB036H4S (460V) TXV 35400 15.1 12 CX35-30/36C SL280UH090XV60C 10247705SSB036H4S (460V) TXV 35200 15 12 CX35-30/36C SL280UH110V60C 10247706SSB036H4S (460V) TXV 35400 15 12 CX35-30/36C SL280UH110XV60C 10247707SSB036H4S (460V) TXV 35000 15 12 CX35-30/36C SLP98UH090XV36C 10247708SSB036H4S (460V) TXV 35200 15 12 CX35-30/36C SLP98UH090XV48C 10247709SSB036H4S (460V) TXV 35600 15 12 CX35-30/36C SLP98UH090XV60C 10247710SSB036H4S (460V) TXV 35400 15 12.2 CX35-30/36C SLP98UH110XV60C 10247711SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36A EL180UH045XE36A 10247712SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36A SL280UH070V36A 10247713SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36A SL280UH070XV36A 10247714SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36B EL180UH070XE36B 10247716SSB036H4S (460V) TXV 36200 15 11.7 CX35-36B EL195UH045XE36B 10247717SSB036H4S (460V) TXV 36200 15.5 12.2 CX35-36B EL195UH070XE36B 10247718SSB036H4S (460V) TXV 36000 15 11.7 CX35-36B EL296UH045XE36B 10247720SSB036H4S (460V) TXV 36200 15.5 12.2 CX35-36B EL296UH045XV36B 10247719SSB036H4S (460V) TXV 36200 15.5 12.2 CX35-36B EL296UH070XE36B 10247721SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36B EL296UH070XV36B 10247722SSB036H4S (460V) TXV 36600 15.5 12.5 CX35-36B SL280UH090V36B 10247723SSB036H4S (460V) TXV 36600 15.5 12.5 CX35-36B SL280UH090V48B 10247724SSB036H4S (460V) TXV 36600 15.5 12.5 CX35-36B SL280UH090XV48B 10247725SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-36B SLP98UH070XV36B 10247726SSB036H4S (460V) TXV 35800 14 11 CX35-36B 10247715SSB036H4S (460V) TXV 36600 15.5 12.2 CX35-48B EL180UH070E36B 10247727SSB036H4S (460V) TXV 36400 15 11.7 CX35-48B EL195UH045XE36B 10247728SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-48B EL195UH070XE36B 10247729SSB036H4S (460V) TXV 36400 15 11.7 CX35-48B EL296UH045XE36B 10247731SSB036H4S (460V) TXV 36600 15.5 12.2 CX35-48B EL296UH045XV36B 10247730SSB036H4S (460V) TXV 36400 15.5 12.2 CX35-48B EL296UH070XE36B 10247732SSB036H4S (460V) TXV 36600 15.5 12.2 CX35-48B EL296UH070XV36B 10247733SSB036H4S (460V) TXV 37000 16 12.5 CX35-48B SL280UH090V36B 10247734SSB036H4S (460V) TXV 36000 16 12.5 CX35-48B SL280UH090V48B 10247735SSB036H4S (460V) TXV 36000 16 12.5 CX35-48B SL280UH090XV48B 10247736SSB036H4S (460V) TXV 36000 15.5 12.2 CX35-48B SLP98UH070XV36B 10247737SSB036H4S (460V) TXV 36600 15.5 12.5 CX35-48C CBWMV-36C-090 10247739SSB036H4S (460V) TXV 37000 16 12.5 CX35-48C CBWMV-60C-100 10247740SSB036H4S (460V) TXV 36600 15.5 12.5 CX35-48C EL296UH090XV36C 10247741SSB036H4S (460V) TXV 36400 15.5 12.5 CX35-48C EL296UH090XV48C 10247742SSB036H4S (460V) TXV 37200 16 12.5 CX35-48C EL296UH090XV60C 10247743SSB036H4S (460V) TXV 36600 16 12.5 CX35-48C EL296UH110XV48C 10247744SSB036H4S (460V) TXV 37000 16 12.5 CX35-48C EL296UH110XV60C 10247745NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 27: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 27

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB036H4S (460V) TXV 37000 15.1 12.5 CX35-48C SL280UH090V60C 10247746SSB036H4S (460V) TXV 37000 15.1 12.5 CX35-48C SL280UH090XV60C 10247747SSB036H4S (460V) TXV 36800 15.1 12.5 CX35-48C SL280UH110V60C 10247748SSB036H4S (460V) TXV 37000 15.1 12.5 CX35-48C SL280UH110XV60C 10247749SSB036H4S (460V) TXV 36800 15.5 12.5 CX35-48C SLP98UH090XV36C 10247750SSB036H4S (460V) TXV 36800 16 12.5 CX35-48C SLP98UH090XV48C 10247751SSB036H4S (460V) TXV 37200 16 12.5 CX35-48C SLP98UH090XV60C 10247752SSB036H4S (460V) TXV 37000 15.5 12.5 CX35-48C SLP98UH110XV60C 10247753SSB036H4S (460V) TXV 36200 14 11.7 CX35-48C 10247738SSB036H4S (460V) TXV 37000 15.5 12.5 CX35-49C EL296UH090XV36C 10247755SSB036H4S (460V) TXV 35800 16 12.5 CX35-49C EL296UH090XV48C 10247756SSB036H4S (460V) TXV 37600 16 12.5 CX35-49C EL296UH090XV60C 10250509SSB036H4S (460V) TXV 37400 16 12.5 CX35-49C EL296UH110XV60C 10247757SSB036H4S (460V) TXV 37600 16 12.5 CX35-49C SL280UH090V60C 10247758SSB036H4S (460V) TXV 37600 16 12.5 CX35-49C SL280UH090XV60C 10247759SSB036H4S (460V) TXV 37200 15.1 12.5 CX35-49C SL280UH110V60C 10247760SSB036H4S (460V) TXV 37400 15.1 12.5 CX35-49C SL280UH110XV60C 10247761SSB036H4S (460V) TXV 37000 16 12.5 CX35-49C SLP98UH090XV36C 10247762SSB036H4S (460V) TXV 37400 16 12.5 CX35-49C SLP98UH090XV48C 10247763SSB036H4S (460V) TXV 37600 16 12.5 CX35-49C SLP98UH090XV60C 10247764SSB036H4S (460V) TXV 37400 14 11.7 CX35-49C SLP98UH110XV60C 10247765SSB036H4S (460V) TXV 36400 14 11.7 CX35-49C 10247754SSB036H4S (460V) TXV 36400 16 12.5 CX35-50/60C EL296UH110XV48C 10247766SSB036H4S (460V) TXV 36800 15.5 12.5 CX38-43B SL280UH090V36B 10555793SSB048H4S (208/230V) TXV 46000 15.5 12 C35-48B EL180UH090E48B 10247995SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48B EL180UH090XE48B 10247994SSB048H4S (208/230V) TXV 45500 15.5 12 C35-48B EL180UH110E60C 10247996SSB048H4S (208/230V) TXV 45500 15 11.7 C35-48B SL280UH090V48C 10247997SSB048H4S (208/230V) TXV 45500 14 11 C35-48B 10247998SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-48C EL180UH090E60C 10247999SSB048H4S (208/230V) TXV 46500 15 11.7 C35-48C EL180UH110E60C 10248000SSB048H4S (208/230V) TXV 45500 15 11.7 C35-48C EL195UH090XE48C 10248001SSB048H4S (208/230V) TXV 46500 15 11.7 C35-48C EL195UH110XE60C 10248002SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C EL296UH090XE48C 10248004SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C EL296UH090XV48C 10248003SSB048H4S (208/230V) TXV 46000 15 11.7 C35-48C EL296UH090XV60C 10248006SSB048H4S (208/230V) TXV 46000 15.5 12 C35-48C EL296UH110XE60C 10248007SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C EL296UH110XV48C 10248005SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C EL296UH110XV60C 10248008SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SL280UH090V60C 10248009SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SL280UH090XV60C 10248010SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SL280UH110V60C 10248011SSB048H4S (208/230V) TXV 46000 15.5 12 C35-48C SL280UH110XV60C 10248012NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 28: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 28

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 46000 15 11.7 C35-48C SLO185BF124/141V60 10248013SSB048H4S (208/230V) TXV 46000 15 11.7 C35-48C SLO185UF124/141V60 10248014SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SLP98UH090XV48C 10248015SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SLP98UH090XV60C 10248016SSB048H4S (208/230V) TXV 46000 15.5 11.7 C35-48C SLP98UH110XV60C 10248017SSB048H4S (208/230V) TXV 45500 14 11 C35-48C 10248018SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL180UH090E60C 10248019SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL180UH110E60C 10248020SSB048H4S (208/230V) TXV 46500 15.5 12.2 C35-49C EL195UH090XE48C 10248021SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL195UH110XE60C 10248022SSB048H4S (208/230V) TXV 46500 15.5 12 C35-49C EL296UH090XE48C 10248023SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL296UH090XV48C 10248024SSB048H4S (208/230V) TXV 46500 15.5 12 C35-49C EL296UH090XV60C 10248025SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL296UH110XE60C 10248026SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL296UH110XV48C 10248027SSB048H4S (208/230V) TXV 46500 16 12 C35-49C EL296UH110XV60C 10248028SSB048H4S (208/230V) TXV 47000 16 12 C35-49C SL280UH090V60C 10248029SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SL280UH090XV60C 10248030SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SL280UH110V60C 10250511SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SL280UH110XV60C 10248031SSB048H4S (208/230V) TXV 46500 15.5 12.2 C35-49C SLO185BF124/141V60 10248032SSB048H4S (208/230V) TXV 46500 15.5 12.2 C35-49C SLO185UF124/141V60 10248033SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SLP98UH090XV48C 10248034SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SLP98UH090XV60C 10248035SSB048H4S (208/230V) TXV 46500 16 12 C35-49C SLP98UH110XV60C 10248036SSB048H4S (208/230V) TXV 46500 14.5 11.7 C35-49C 10248037SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C ECBWMV-60C-100 10248038SSB048H4S (208/230V) TXV 45500 15.5 12 C35-50/60C EL180UH090E60C 10248039SSB048H4S (208/230V) TXV 45500 15 11.7 C35-50/60C EL180UH110E60C 10253744SSB048H4S (208/230V) TXV 45000 15 11.7 C35-50/60C EL195UH090XE48C 10248040SSB048H4S (208/230V) TXV 45500 15 11.7 C35-50/60C EL195UH110XE60C 10248041SSB048H4S (208/230V) TXV 45500 15 11.7 C35-50/60C EL296UH090XE48C 10248042SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C EL296UH090XV48C 10248043SSB048H4S (208/230V) TXV 45500 15 11.7 C35-50/60C EL296UH090XV60C 10248044SSB048H4S (208/230V) TXV 45500 15.5 12 C35-50/60C EL296UH110XE60C 10248045SSB048H4S (208/230V) TXV 45000 15.5 11.7 C35-50/60C EL296UH110XV48C 10248046SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C EL296UH110XV60C 10248047SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SL280UH090V60C 10248048SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SL280UH090XV60C 10248049SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SL280UH110V60C 10248050SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SL280UH110XV60C 10248051SSB048H4S (208/230V) TXV 45000 15 11.7 C35-50/60C SLO185BF124/141V60 10248052SSB048H4S (208/230V) TXV 45000 15 11.7 C35-50/60C SLO185UF124/141V60 10248053NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 29: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 29

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH090XV48C 10248054SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH090XV60C 10248055SSB048H4S (208/230V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH110XV60C 10248056SSB048H4S (208/230V) TXV 45000 14 11 C35-50/60C 10248057SSB048H4S (208/230V) TXV 47000 16 12.5 C35-60C EL180UH090E60C 10248058SSB048H4S (208/230V) TXV 47000 16 12.5 C35-60C EL180UH110E60C 10248059SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL195UH090XE48C 10248060SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL195UH110XE60C 10248061SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL296UH090XE48C 10248062SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL296UH090XV48C 10248063SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL296UH090XV60C 10248064SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL296UH110XE60C 10248065SSB048H4S (208/230V) TXV 47000 16 12 C35-60C EL296UH110XV48C 10248066SSB048H4S (208/230V) TXV 47500 16 12 C35-60C EL296UH110XV60C 10248067SSB048H4S (208/230V) TXV 47500 16.5 12.2 C35-60C SL280UH090V60C 10248068SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SL280UH090XV60C 10248069SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SL280UH110V60C 10248070SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SL280UH110XV60C 10248071SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SLO185BF124/141V60 10248072SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SLO185UF124/141V60 10248073SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SLP98UH090XV48C 10248074SSB048H4S (208/230V) TXV 47000 16 12 C35-60C SLP98UH090XV60C 10248075SSB048H4S (208/230V) TXV 47500 16 12 C35-60C SLP98UH110XV60C 10248076SSB048H4S (208/230V) TXV 47000 14.5 11.7 C35-60C 10248077SSB048H4S (208/230V) TXV 47000 16 12 C35-60D EL296UH135XV60D 10248078SSB048H4S (208/230V) TXV 47000 16 12 C35-60D SL280UH135V60D 10248079SSB048H4S (208/230V) TXV 46500 15.5 12.2 C35-60D SLO185BF124/141V60 10248080SSB048H4S (208/230V) TXV 46500 15.5 12.2 C35-60D SLO185UF124/141V60 10248081SSB048H4S (208/230V) TXV 47000 16 12 C35-60D SLP98UH135XV60D 10248082SSB048H4S (208/230V) TXV 46500 14.5 11.7 C35-60D 10248083SSB048H4S (208/230V) TXV 47000 16 12.2 CBA27UHE-048 10259520SSB048H4S (208/230V) TXV 46500 16 12.2 CBA27UHE-060 10259521SSB048H4S (208/230V) TXV 46000 14 11.5 CBX25UH-048 6673060SSB048H4S (208/230V) TXV 46000 16 12 CBX27UH-048 6673056SSB048H4S (208/230V) TXV 46500 16 12 CBX27UH-060 6673057SSB048H4S (208/230V) TXV 46000 15 12 CBX32M-048 6673062SSB048H4S (208/230V) TXV 47000 14 12 CBX32M-060 6673063SSB048H4S (208/230V) TXV 46000 16 12 CBX32MV-048 6673064SSB048H4S (208/230V) TXV 47000 16 12 CBX32MV-060 6673065SSB048H4S (208/230V) TXV 47000 16 12 CBX32MV-068 6673066SSB048H4S (208/230V) TXV 45500 15.5 12 CBX40UHV-048 6673402SSB048H4S (208/230V) TXV 46000 15.5 12 CBX40UHV-060 6673403SSB048H4S (208/230V) TXV 44000 14.5 11.5 CH23-51 EL180UH090E48B 6673407NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 30: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 30

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 EL180UH090E60C 6673408SSB048H4S (208/230V) TXV 43500 15 11.7 CH23-51 EL180UH110E60C 6673409SSB048H4S (208/230V) TXV 44000 14.5 11.5 CH23-51 EL195UH090XE48C 6673067SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 EL195UH110XE60C 6673068SSB048H4S (208/230V) TXV 44000 14.5 11.5 CH23-51 EL296UH090XE48C 6673405SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 EL296UH090XV48C 6673069SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 EL296UH090XV60C 6673070SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 EL296UH110XE60C 6673406SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 EL296UH110XV48C 6673071SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 EL296UH110XV60C 6673072SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 EL296UH135XV60D 6673073SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SL280UH090V60C 6673077SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 SL280UH090XV60C 6673410SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 SL280UH110V60C 6673078SSB048H4S (208/230V) TXV 44000 15 11.7 CH23-51 SL280UH110XV60C 6673411SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SL280UH135V60D 6673079SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SLP98UH090XV48C 6673080SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SLP98UH090XV60C 6673082SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SLP98UH110XV60C 6673083SSB048H4S (208/230V) TXV 44000 15 11.5 CH23-51 SLP98UH135XV60D 6673084SSB048H4S (208/230V) TXV 44500 15 11.7 CH23-65 EL180UH090E60C 6673415SSB048H4S (208/230V) TXV 44500 15 11.7 CH23-65 EL180UH110E60C 6673416SSB048H4S (208/230V) TXV 44500 15 11.7 CH23-65 EL195UH090XE48C 6673085SSB048H4S (208/230V) TXV 44500 15 11.7 CH23-65 EL195UH110XE60C 6673086SSB048H4S (208/230V) TXV 44500 15 11.5 CH23-65 EL296UH090XE48C 6673413SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 EL296UH090XV48C 6673087SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 EL296UH090XV60C 6673088SSB048H4S (208/230V) TXV 44500 15 11.7 CH23-65 EL296UH110XE60C 6673414SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 EL296UH110XV48C 6673089SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 EL296UH110XV60C 6673090SSB048H4S (208/230V) TXV 45000 15.5 12 CH23-65 EL296UH135XV60D 6673091SSB048H4S (208/230V) TXV 45000 15.5 12 CH23-65 SL280UH090V60C 6673094SSB048H4S (208/230V) TXV 45000 15.5 12 CH23-65 SL280UH090XV48B 6679413SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 SL280UH110V60C 6673095SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 SL280UH110XV60C 6679414SSB048H4S (208/230V) TXV 45000 15.5 12 CH23-65 SL280UH135V60D 6673096SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 SLP98UH090XV48C 6673097SSB048H4S (208/230V) TXV 44500 15.5 11.7 CH23-65 SLP98UH090XV60C 6673098SSB048H4S (208/230V) TXV 45000 15.5 11.7 CH23-65 SLP98UH110XV60C 6673099SSB048H4S (208/230V) TXV 45000 15.5 12 CH23-65 SLP98UH135XV60D 6673100SSB048H4S (208/230V) TXV 46500 15.5 12.2 CH23-68 EL180UH090E60C 6673417SSB048H4S (208/230V) TXV 46000 15.5 12.2 CH23-68 EL180UH110E60C 6673418SSB048H4S (208/230V) TXV 46500 15.5 12.2 CH23-68 EL195UH090XE48C 6673102NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 31: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 31

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 46500 16 12 CH23-68 EL195UH110XE60C 6673103SSB048H4S (208/230V) TXV 46000 15.5 12 CH23-68 EL296UH090XE48C 6673419SSB048H4S (208/230V) TXV 46000 15.5 12 CH23-68 EL296UH110XE60C 6673420SSB048H4S (208/230V) TXV 46500 16 12 CH23-68 EL296UH135XV60D 6673104SSB048H4S (208/230V) TXV 46500 16 12 CH23-68 SL280UH135V60D 6673107SSB048H4S (208/230V) TXV 46500 16 12 CH23-68 SLP98UH135XV60D 6673108SSB048H4S (208/230V) TXV 46000 14 11.5 CH23-68 6673101SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-43 SL280UH090V48B 6673421SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-43 SL280UH090XV48B 6673422SSB048H4S (208/230V) TXV 46000 15.5 12.2 CH33-43C EL180UH090E60C 6677942SSB048H4S (208/230V) TXV 45500 15.5 12.2 CH33-43C EL180UH110E60C 6677943SSB048H4S (208/230V) TXV 45500 15 11.7 CH33-43C EL195UH090XE48C 6673109SSB048H4S (208/230V) TXV 46000 15 11.7 CH33-43C EL195UH110XE60C 6673110SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-43C EL296UH090XE48C 6673423SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-43C EL296UH110XE60C 6673424SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-43C EL296UH110XV48C 6673111SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-44/48 EL180UH090E48B 6673425SSB048H4S (208/230V) TXV 45000 15 11.5 CH33-44/48 SL280UH090V48B 6673426SSB048H4S (208/230V) TXV 45000 15 11.5 CH33-44/48 SL280UH090XV48B 6673427SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 EL296UH090XV48C 6673118SSB048H4S (208/230V) TXV 45500 15 11.7 CH33-48 EL296UH090XV60C 6673119SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 EL296UH110XV48C 6673120SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 EL296UH110XV60C 6673121SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SL280UH090V60C 6673124SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SL280UH090XV60C 6673428SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SL280UH110V60C 6673125SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SL280UH110XV60C 6673429SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SLP98UH090XV48C 6673126SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SLP98UH090XV60C 6673127SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48 SLP98UH110XV60C 6673128SSB048H4S (208/230V) TXV 45500 15.5 12 CH33-48C EL180UH090E60C 6673430SSB048H4S (208/230V) TXV 45500 15.5 12.2 CH33-48C EL180UH110E60C 6673431SSB048H4S (208/230V) TXV 45000 15 11.7 CH33-48C EL195UH090XE48C 6673116SSB048H4S (208/230V) TXV 46000 15 11.7 CH33-48C EL195UH110XE60C 6673117SSB048H4S (208/230V) TXV 45500 15.5 11.7 CH33-48C EL296UH090XE48C 6673432SSB048H4S (208/230V) TXV 45500 15.5 12 CH33-48C EL296UH110XE60C 6673433SSB048H4S (208/230V) TXV 45000 14 11 CH33-48C 6673115SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 EL296UH090XV48C 6673129SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 EL296UH090XV60C 6673130SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 EL296UH110XV48C 6673131SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 EL296UH110XV60C 6673132SSB048H4S (208/230V) TXV 46500 16 12 CH33-49 SL280UH090V60C 6673133SSB048H4S (208/230V) TXV 46500 16 12 CH33-49 SL280UH090XV60C 6673435NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 32: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 32

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 SL280UH110V60C 6673139SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 SL280UH110XV60C 6673436SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 SLP98UH090XV48C 6673140SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 SLP98UH090XV60C 6673141SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-49 SLP98UH110XV60C 6673142SSB048H4S (208/230V) TXV 46000 14.5 11.5 CH33-49 6673434SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C CBWMV-60C-100 6673437SSB048H4S (208/230V) TXV 46000 16 12 CH33-50/60C EL180UH090E60C 6673438SSB048H4S (208/230V) TXV 46000 16 12 CH33-50/60C EL180UH110E60C 6673439SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL195UH090XE48C 6673144SSB048H4S (208/230V) TXV 46500 15.5 11.7 CH33-50/60C EL195UH110XE60C 6673145SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL296UH090XE48C 6673993SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL296UH090XE48C 6679415SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH090XV48C 6673146SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH090XV60C 6673147SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XE60C 6673994SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XE60C 6679416SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XV48C 6673148SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH110XV60C 6673149SSB048H4S (208/230V) TXV 46500 16 12 CH33-50/60C SL280UH090V60C 6673152SSB048H4S (208/230V) TXV 46500 15.5 12.2 CH33-50/60C SL280UH090XV60C 6673440SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C SL280UH110V60C 6673153SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-50/60C SL280UH110XV60C 6673441SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH090XV48C 6673154SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH090XV60C 6673155SSB048H4S (208/230V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH110XV60C 6673156SSB048H4S (208/230V) TXV 46000 14.5 11.5 CH33-50/60C 6673143SSB048H4S (208/230V) TXV 46000 16 12 CH33-60D EL296UH135XV60D 6673158SSB048H4S (208/230V) TXV 46000 16 12 CH33-60D SL280UH135V60D 6673159SSB048H4S (208/230V) TXV 46000 15.5 12 CH33-60D SLP98UH135XV60D 6673160SSB048H4S (208/230V) TXV 45500 14 11.5 CH33-60D 6673157SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-62D EL296UH090XV60C 8341588SSB048H4S (208/230V) TXV 46500 15.5 12 CH33-62D EL296UH110XV60C 8341589SSB048H4S (208/230V) TXV 46500 16 12 CH33-62D EL296UH135XV60D 6673162SSB048H4S (208/230V) TXV 46500 16 12 CH33-62D SL280UH135V60D 6673163SSB048H4S (208/230V) TXV 46500 16 12 CH33-62D SLP98UH135XV60D 6673164SSB048H4S (208/230V) TXV 46000 14.5 11.5 CH33-62D 6673161SSB048H4S (208/230V) TXV 44500 15 11.7 CR33-48 EL180DF110E60C 6673169SSB048H4S (208/230V) TXV 44000 15 11.5 CR33-48 EL195DF090XE48C 6673165SSB048H4S (208/230V) TXV 44500 15 11 CR33-48 EL195DF110XE60C 6673166SSB048H4S (208/230V) TXV 44500 15 11.5 CR33-48 EL296DF090XE48C 6673443SSB048H4S (208/230V) TXV 44500 15 11 CR33-48 EL296DF090XV60C 6673167SSB048H4S (208/230V) TXV 44500 15 11.7 CR33-48 EL296DF110XE60C 6673444NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 33: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 33

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 44500 15 11 CR33-48 EL296DF110XV60C 6673168SSB048H4S (208/230V) TXV 44500 15 11.7 CR33-48 SL280DF090V60C 6673170SSB048H4S (208/230V) TXV 44500 15.5 11.7 CR33-48 SL280DF110V60C 6673171SSB048H4S (208/230V) TXV 44500 15 11 CR33-48 SLP98DF090XV48C 6673445SSB048H4S (208/230V) TXV 44500 15 11 CR33-48 SLP98DF090XV60C 6673446SSB048H4S (208/230V) TXV 44500 15 11.5 CR33-48 SLP98DF110XV60C 6673447SSB048H4S (208/230V) TXV 44000 14 11 CR33-48 6673448SSB048H4S (208/230V) TXV 45000 15.5 12 CR33-50/60 EL180DF110E60C 6673450SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 EL195DF090XE48C 6673172SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 EL195DF110XE60C 6673173SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 EL296DF090XE48C 6673451SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 EL296DF090XV60C 6673174SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 EL296DF110XE60C 6673452SSB048H4S (208/230V) TXV 45000 15 11.5 CR33-50/60 EL296DF110XV60C 6673175SSB048H4S (208/230V) TXV 45000 15.5 11.7 CR33-50/60 SL280DF090V60C 6673177SSB048H4S (208/230V) TXV 45000 15.5 12 CR33-50/60 SL280DF110V60C 6673178SSB048H4S (208/230V) TXV 45000 15 11.5 CR33-50/60 SLP98DF090XV48C 6673453SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 SLP98DF090XV60C 6673454SSB048H4S (208/230V) TXV 45000 15 11.7 CR33-50/60 SLP98DF110XV60C 6673455SSB048H4S (208/230V) TXV 44500 14 11 CR33-50/60 6673449SSB048H4S (208/230V) TXV 44500 14 11 CR33-60 6673456SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48B EL180UH090E48B 10248084SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48B EL180UH090E60C 10248085SSB048H4S (208/230V) TXV 45500 15.5 12 CX35-48B EL180UH110E60C 10248086SSB048H4S (208/230V) TXV 45500 15 11.7 CX35-48B SL280UH090V48B 10248087SSB048H4S (208/230V) TXV 45500 14 11 CX35-48B 10248088SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-48C EL180UH090E60C 10248089SSB048H4S (208/230V) TXV 46500 15 11.7 CX35-48C EL180UH110E60C 10248090SSB048H4S (208/230V) TXV 45500 15 11.7 CX35-48C EL195UH090XE48C 10248091SSB048H4S (208/230V) TXV 46500 15 11.7 CX35-48C EL195UH110XE60C 10248092SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XE48C 10248093SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XV48C 10248094SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XV60C 10248095SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C EL296UH110XE60C 10248096SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C EL296UH110XV48C 10248097SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C EL296UH110XV60C 10248098SSB048H4S (208/230V) TXV 46000 16 12 CX35-48C SL280UH090V60C 10248099SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C SL280UH090XV60C 10248100SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C SL280UH110V60C 10248101SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C SL280UH110XV60C 10248102SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C SLO185BF124/141V60 10248103SSB048H4S (208/230V) TXV 46000 15.5 12 CX35-48C SLO185UF124/141V60 10248104SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C SLP98UH090XV48C 10248105NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 34: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 34

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C SLP98UH090XV60C 10248106SSB048H4S (208/230V) TXV 46000 15.5 11.7 CX35-48C SLP98UH110XV60C 10248107SSB048H4S (208/230V) TXV 45500 14 11 CX35-48C 10248108SSB048H4S (208/230V) TXV 46500 15 12 CX35-49C EL180UH090E60C 10248109SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL180UH110E60C 10248110SSB048H4S (208/230V) TXV 46500 15.5 12.2 CX35-49C EL195UH090XE48C 10248111SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL195UH110XE60C 10248112SSB048H4S (208/230V) TXV 46500 15.5 12 CX35-49C EL296UH090XE48C 10248113SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL296UH090XV48C 10248114SSB048H4S (208/230V) TXV 46500 15.5 12 CX35-49C EL296UH090XV60C 10248115SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL296UH110XE60C 10248116SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL296UH110XV48C 10248117SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C EL296UH110XV60C 10248118SSB048H4S (208/230V) TXV 47000 16 12 CX35-49C SL280UH090V60C 10248119SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SL280UH090XV60C 10248120SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SL280UH110V60C 10248121SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SL280UH110XV60C 10248122SSB048H4S (208/230V) TXV 46500 15.5 12.2 CX35-49C SLO185BF124/141V60 10248123SSB048H4S (208/230V) TXV 46500 15.5 12.2 CX35-49C SLO185UF124/141V60 10248124SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SLP98UH090XV48C 10248125SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SLP98UH090XV60C 10248126SSB048H4S (208/230V) TXV 46500 16 12 CX35-49C SLP98UH110XV60C 10248127SSB048H4S (208/230V) TXV 46500 14.5 11.7 CX35-49C 10248128SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C CBWMV-60C-100 10248129SSB048H4S (208/230V) TXV 45500 15.5 12 CX35-50/60C EL180UH090E60C 10248130SSB048H4S (208/230V) TXV 45000 15 11.7 CX35-50/60C EL180UH110E60C 10254153SSB048H4S (208/230V) TXV 45000 15 11.7 CX35-50/60C EL195UH090XE48C 10248131SSB048H4S (208/230V) TXV 45500 15 11.7 CX35-50/60C EL195UH110XE60C 10248132SSB048H4S (208/230V) TXV 45500 15 11.7 CX35-50/60C EL296UH090XE48C 10248133SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH090XV48C 10248134SSB048H4S (208/230V) TXV 45500 15 11.7 CX35-50/60C EL296UH090XV60C 10248135SSB048H4S (208/230V) TXV 45500 15.5 12 CX35-50/60C EL296UH110XE60C 10248136SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH110XV48C 10248137SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH110XV60C 10248138SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH090V60C 10248139SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH090XV60C 10248140SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH110V60C 10250512SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH110XV60C 10248141SSB048H4S (208/230V) TXV 45000 15 11.7 CX35-50/60C SLO185BF124/141V60 10248142SSB048H4S (208/230V) TXV 45000 15 11.7 CX35-50/60C SLO185UF124/141V60 10248143SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH090XV48C 10248144SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH090XV60C 10250513SSB048H4S (208/230V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH110XV60C 10248145NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 35: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 35

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (208/230V) TXV 45000 14 11 CX35-50/60C 10248146SSB048H4S (208/230V) TXV 47000 16 12.5 CX35-60C EL180UH090E60C 10248147SSB048H4S (208/230V) TXV 47000 16 12.5 CX35-60C EL180UH110XE60C 10248148SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL195UH090XE48C 10248149SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL195UH110XE60C 10248150SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL296UH090XE48C 10248151SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL296UH090XV48C 10248152SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL296UH090XV60C 10248153SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL296UH110XE60C 10248154SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C EL296UH110XV48C 10248155SSB048H4S (208/230V) TXV 47500 16 12 CX35-60C EL296UH110XV60C 10248156SSB048H4S (208/230V) TXV 47500 16.5 12.2 CX35-60C SL280UH090V60C 10248157SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SL280UH090XV60C 10248158SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SL280UH110V60C 10248159SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SL280UH110XV60C 10248160SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SLO185BF124/141V60 10248161SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SLO185UF124/141V60 10248162SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SLP98UH090XV48C 10248163SSB048H4S (208/230V) TXV 47000 16 12 CX35-60C SLP98UH090XV60C 10248164SSB048H4S (208/230V) TXV 47500 16 12 CX35-60C SLP98UH110XV60C 10248165SSB048H4S (208/230V) TXV 47000 14.5 11.7 CX35-60C 10248166SSB048H4S (208/230V) TXV 47000 16 12 CX35-60D EL296UH135XV60D 10248167SSB048H4S (208/230V) TXV 47000 16 12 CX35-60D SL280UH135V60D 10248168SSB048H4S (208/230V) TXV 46500 15.5 12.2 CX35-60D SLO185BF124/141V60 10248169SSB048H4S (208/230V) TXV 46500 15.5 12.2 CX35-60D SLO185UF124/141V60 10248170SSB048H4S (208/230V) TXV 47000 16 12 CX35-60D SLP98UH135XV60D 10248171SSB048H4S (208/230V) TXV 46500 14.5 11 CX35-60D 10248172SSB048H4S (208/230V) TXV 47000 16 12 CX38-62C SL280UH090XV60C 10555936SSB048H4S (460V) TXV 46000 15.5 12 C35-48B EL180UH090E48B 10247814SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48B EL180UH090XE48B 10247813SSB048H4S (460V) TXV 45500 15.5 12 C35-48B EL180UH110E60C 10247815SSB048H4S (460V) TXV 45500 15 11.7 C35-48B SL280UH090V48C 10247816SSB048H4S (460V) TXV 45500 14 11 C35-48B 10247817SSB048H4S (460V) TXV 45500 15.5 11.7 C35-48C EL180UH090E60C 10247818SSB048H4S (460V) TXV 46500 15 11.7 C35-48C EL180UH110E60C 10247819SSB048H4S (460V) TXV 45500 15 11.7 C35-48C EL195UH090XE48C 10247820SSB048H4S (460V) TXV 46500 15 11.7 C35-48C EL195UH110XE60C 10247821SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C EL296UH090XE48C 10247823SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C EL296UH090XV48C 10247822SSB048H4S (460V) TXV 46000 15 11.7 C35-48C EL296UH090XV60C 10247825SSB048H4S (460V) TXV 46000 15.5 12 C35-48C EL296UH110XE60C 10247826SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C EL296UH110XV48C 10247824SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C EL296UH110XV60C 10247827NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 36: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 36

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SL280UH090V60C 10247828SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SL280UH090XV60C 10247829SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SL280UH110V60C 10247830SSB048H4S (460V) TXV 46000 15.5 12 C35-48C SL280UH110XV60C 10247831SSB048H4S (460V) TXV 46000 15 11.7 C35-48C SLO185BF124/141V60 10247832SSB048H4S (460V) TXV 46000 15 11.7 C35-48C SLO185UF124/141V60 10247833SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SLP98UH090XV48C 10247834SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SLP98UH090XV60C 10247835SSB048H4S (460V) TXV 46000 15.5 11.7 C35-48C SLP98UH110XV60C 10247836SSB048H4S (460V) TXV 45500 14 11 C35-48C 10247837SSB048H4S (460V) TXV 46500 16 12 C35-49C EL180UH090E60C 10247838SSB048H4S (460V) TXV 46500 16 12 C35-49C EL180UH110E60C 10247839SSB048H4S (460V) TXV 46500 15.5 12.2 C35-49C EL195UH090XE48C 10247840SSB048H4S (460V) TXV 46500 16 12 C35-49C EL195UH110XE60C 10247841SSB048H4S (460V) TXV 46500 15.5 12 C35-49C EL296UH090XE48C 10247842SSB048H4S (460V) TXV 46500 16 12 C35-49C EL296UH090XV48C 10247843SSB048H4S (460V) TXV 46500 15.5 12 C35-49C EL296UH090XV60C 10247844SSB048H4S (460V) TXV 46500 16 12 C35-49C EL296UH110XE60C 10247845SSB048H4S (460V) TXV 46500 16 12 C35-49C EL296UH110XV48C 10247846SSB048H4S (460V) TXV 46500 16 12 C35-49C EL296UH110XV60C 10247847SSB048H4S (460V) TXV 47000 16 12 C35-49C SL280UH090V60C 10247848SSB048H4S (460V) TXV 46500 16 12 C35-49C SL280UH090XV60C 10247849SSB048H4S (460V) TXV 46500 16 12 C35-49C SL280UH110V60C 10247850SSB048H4S (460V) TXV 46500 16 12 C35-49C SL280UH110XV60C 10247851SSB048H4S (460V) TXV 46500 15.5 12.2 C35-49C SLO185BF124/141V60 10247852SSB048H4S (460V) TXV 46500 15.5 12.2 C35-49C SLO185UF124/141V60 10247853SSB048H4S (460V) TXV 46500 16 12 C35-49C SLP98UH090XV48C 10247854SSB048H4S (460V) TXV 46500 16 12 C35-49C SLP98UH090XV60C 10247855SSB048H4S (460V) TXV 46500 16 12 C35-49C SLP98UH110XV60C 10247856SSB048H4S (460V) TXV 46500 14.5 11.7 C35-49C 10247857SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C ECBWMV-60C-100 10247858SSB048H4S (460V) TXV 45500 15.5 12 C35-50/60C EL180UH090E60C 10247859SSB048H4S (460V) TXV 45500 15 11.7 C35-50/60C EL180UH110E60C 10253743SSB048H4S (460V) TXV 45000 15 11.7 C35-50/60C EL195UH090XE48C 10247860SSB048H4S (460V) TXV 45500 15 11.7 C35-50/60C EL195UH110XE60C 10247861SSB048H4S (460V) TXV 45500 15 11.7 C35-50/60C EL296UH090XE48C 10247862SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C EL296UH090XV48C 10247863SSB048H4S (460V) TXV 45500 15 11.7 C35-50/60C EL296UH090XV60C 10247864SSB048H4S (460V) TXV 45500 15.5 12 C35-50/60C EL296UH110XE60C 10247865SSB048H4S (460V) TXV 45000 15.5 11.7 C35-50/60C EL296UH110XV48C 10247866SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C EL296UH110XV60C 10247867SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SL280UH090V60C 10247868SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SL280UH090XV60C 10247869NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 37: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 37

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SL280UH110V60C 10247870SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SL280UH110XV60C 10247871SSB048H4S (460V) TXV 45000 15 11.7 C35-50/60C SLO185BF124/141V60 10247872SSB048H4S (460V) TXV 45000 15 11.7 C35-50/60C SLO185UF124/141V60 10247873SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH090XV48C 10247874SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH090XV60C 10247875SSB048H4S (460V) TXV 45500 15.5 11.7 C35-50/60C SLP98UH110XV60C 10247876SSB048H4S (460V) TXV 45000 14 11 C35-50/60C 10247877SSB048H4S (460V) TXV 47000 16 12.5 C35-60C EL180UH090E60C 10247878SSB048H4S (460V) TXV 47000 16 12.5 C35-60C EL180UH110E60C 10247879SSB048H4S (460V) TXV 47000 16 12 C35-60C EL195UH090XE48C 10247880SSB048H4S (460V) TXV 47000 16 12 C35-60C EL195UH110XE60C 10247881SSB048H4S (460V) TXV 47000 16 12 C35-60C EL296UH090XE48C 10247882SSB048H4S (460V) TXV 47000 16 12 C35-60C EL296UH090XV48C 10247883SSB048H4S (460V) TXV 47000 16 12 C35-60C EL296UH090XV60C 10247884SSB048H4S (460V) TXV 47000 16 12 C35-60C EL296UH110XE60C 10247885SSB048H4S (460V) TXV 47000 16 12 C35-60C EL296UH110XV48C 10247886SSB048H4S (460V) TXV 47500 16 12 C35-60C EL296UH110XV60C 10247887SSB048H4S (460V) TXV 47500 16.5 12.2 C35-60C SL280UH090V60C 10247888SSB048H4S (460V) TXV 47000 16 12 C35-60C SL280UH090XV60C 10247889SSB048H4S (460V) TXV 47000 16 12 C35-60C SL280UH110V60C 10247890SSB048H4S (460V) TXV 47000 16 12 C35-60C SL280UH110XV60C 10247891SSB048H4S (460V) TXV 47000 16 12 C35-60C SLO185BF124/141V60 10247892SSB048H4S (460V) TXV 47000 16 12 C35-60C SLO185UF124/141V60 10247893SSB048H4S (460V) TXV 47000 16 12 C35-60C SLP98UH090XV48C 10247894SSB048H4S (460V) TXV 47000 16 12 C35-60C SLP98UH090XV60C 10247895SSB048H4S (460V) TXV 47500 16 12 C35-60C SLP98UH110XV60C 10247896SSB048H4S (460V) TXV 47000 14.5 11.7 C35-60C 10247897SSB048H4S (460V) TXV 47000 16 12 C35-60D EL296UH135XV60D 10247898SSB048H4S (460V) TXV 47000 16 12 C35-60D SL280UH135V60D 10247899SSB048H4S (460V) TXV 46500 15.5 12.2 C35-60D SLO185BF124/141V60 10247900SSB048H4S (460V) TXV 46500 15.5 12.2 C35-60D SLO185UF124/141V60 10247901SSB048H4S (460V) TXV 47000 16 12 C35-60D SLP98UH135XV60D 10247902SSB048H4S (460V) TXV 46500 14.5 11.7 C35-60D 10247903SSB048H4S (460V) TXV 47000 16 12.2 CBA27UHE-048 10259522SSB048H4S (460V) TXV 46500 16 12.2 CBA27UHE-060 10259523SSB048H4S (460V) TXV 46000 14 11.5 CBX25UH-048 6673466SSB048H4S (460V) TXV 46000 16 12 CBX27UH-048 6673462SSB048H4S (460V) TXV 46500 16 12 CBX27UH-060 6673463SSB048H4S (460V) TXV 46000 15 12 CBX32M-048 6673468SSB048H4S (460V) TXV 47000 14 12 CBX32M-060 6673469SSB048H4S (460V) TXV 46000 16 12 CBX32MV-048 6673470SSB048H4S (460V) TXV 47000 16 12 CBX32MV-060 6673471NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 38: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 38

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 47000 16 12 CBX32MV-068 6673472SSB048H4S (460V) TXV 45500 15.5 12 CBX40UHV-048 6673802SSB048H4S (460V) TXV 46000 15.5 12 CBX40UHV-060 6673803SSB048H4S (460V) TXV 44000 14.5 11.5 CH23-51 EL180UH090E48B 6673807SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 EL180UH090E60C 6673808SSB048H4S (460V) TXV 43500 15 11.7 CH23-51 EL180UH110E60C 6673809SSB048H4S (460V) TXV 44000 14.5 11.5 CH23-51 EL195UH090XE48C 6673473SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 EL195UH110XE60C 6673474SSB048H4S (460V) TXV 44000 14.5 11.5 CH23-51 EL296UH090XE48C 6673805SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 EL296UH090XV48C 6673475SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 EL296UH090XV60C 6673476SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 EL296UH110XE60C 6673806SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 EL296UH110XV48C 6673477SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 EL296UH110XV60C 6673478SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 EL296UH135XV60D 6673479SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SL280UH090V60C 6673483SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 SL280UH090XV60C 6673810SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 SL280UH110V60C 6673484SSB048H4S (460V) TXV 44000 15 11.7 CH23-51 SL280UH110XV60C 6673811SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SL280UH135V60D 6673485SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SLP98UH090XV48C 6673486SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SLP98UH090XV60C 6673487SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SLP98UH110XV60C 6673488SSB048H4S (460V) TXV 44000 15 11.5 CH23-51 SLP98UH135XV60D 6673489SSB048H4S (460V) TXV 44500 15 11.7 CH23-65 EL180UH090E60C 6673815SSB048H4S (460V) TXV 44500 15 11.7 CH23-65 EL180UH110E60C 6673816SSB048H4S (460V) TXV 44500 15 11.7 CH23-65 EL195UH090XE48C 6673490SSB048H4S (460V) TXV 44500 15 11.7 CH23-65 EL195UH110XE60C 6673491SSB048H4S (460V) TXV 44500 15 11.5 CH23-65 EL296UH090XE48C 6673813SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 EL296UH090XV48C 6673492SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 EL296UH090XV60C 6673493SSB048H4S (460V) TXV 44500 15 11.7 CH23-65 EL296UH110XE60C 6673814SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 EL296UH110XV48C 6673494SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 EL296UH110XV60C 6673495SSB048H4S (460V) TXV 45000 15.5 12 CH23-65 EL296UH135XV60D 6673496SSB048H4S (460V) TXV 45000 15.5 12 CH23-65 SL280UH090V60C 6673499SSB048H4S (460V) TXV 45000 15.5 12 CH23-65 SL280UH090XV48B 6679421SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 SL280UH110V60C 6673500SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 SL280UH110XV60C 6679422SSB048H4S (460V) TXV 45000 15.5 12 CH23-65 SL280UH135V60D 6673501SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 SLP98UH090XV48C 6673502SSB048H4S (460V) TXV 44500 15.5 11.7 CH23-65 SLP98UH090XV60C 6673503SSB048H4S (460V) TXV 45000 15.5 11.7 CH23-65 SLP98UH110XV60C 6673504NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 39: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 39

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 45000 15.5 12 CH23-65 SLP98UH135XV60D 6673505SSB048H4S (460V) TXV 46500 15.5 12.2 CH23-68 EL180UH090E60C 6673817SSB048H4S (460V) TXV 46000 15.5 12.2 CH23-68 EL180UH110E60C 6673818SSB048H4S (460V) TXV 46500 15.5 12.2 CH23-68 EL195UH090XE48C 6673507SSB048H4S (460V) TXV 46500 16 12 CH23-68 EL195UH110XE60C 6673508SSB048H4S (460V) TXV 46000 15.5 12 CH23-68 EL296UH090XE48C 6673819SSB048H4S (460V) TXV 46000 15.5 12 CH23-68 EL296UH110XE60C 6673820SSB048H4S (460V) TXV 46500 16 12 CH23-68 EL296UH135XV60D 6673509SSB048H4S (460V) TXV 46500 16 12 CH23-68 SL280UH135V60D 6673512SSB048H4S (460V) TXV 46500 16 12 CH23-68 SLP98UH135XV60D 6673513SSB048H4S (460V) TXV 46000 14 11.5 CH23-68 6673506SSB048H4S (460V) TXV 46500 15.5 12 CH33-43 SL280UH090V48B 6673821SSB048H4S (460V) TXV 46500 15.5 12 CH33-43 SL280UH090XV48B 6673822SSB048H4S (460V) TXV 46000 15.5 12.2 CH33-43C EL180UH090E60C 6677944SSB048H4S (460V) TXV 45500 15.5 12.2 CH33-43C EL180UH110E60C 6677945SSB048H4S (460V) TXV 45500 15 11.7 CH33-43C EL195UH090XE48C 6673514SSB048H4S (460V) TXV 46000 15 11.7 CH33-43C EL195UH110XE60C 6673515SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-43C EL296UH090XE48C 6673823SSB048H4S (460V) TXV 46000 15.5 12 CH33-43C EL296UH110XE60C 6673824SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-43C EL296UH110XV48C 6673516SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-44/48 EL180UH090E48B 6673825SSB048H4S (460V) TXV 45000 15 11.5 CH33-44/48 SL280UH090V48B 6673826SSB048H4S (460V) TXV 45000 15 11.5 CH33-44/48 SL280UH090XV48B 6673827SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 EL296UH090XV48C 6673523SSB048H4S (460V) TXV 45500 15 11.7 CH33-48 EL296UH090XV60C 6673524SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 EL296UH110XV48C 6673525SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 EL296UH110XV60C 6673526SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SL280UH090V60C 6673529SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SL280UH090XV60C 6673828SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SL280UH110V60C 6673530SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SL280UH110XV60C 6673829SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SLP98UH090XV48C 6673531SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SLP98UH090XV60C 6673532SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48 SLP98UH110XV60C 6673533SSB048H4S (460V) TXV 45500 15.5 12 CH33-48C EL180UH090E60C 6673830SSB048H4S (460V) TXV 45500 15.5 12.2 CH33-48C EL180UH110E60C 6673831SSB048H4S (460V) TXV 45000 15 11.7 CH33-48C EL195UH090XE48C 6673521SSB048H4S (460V) TXV 46000 15 11.7 CH33-48C EL195UH110XE60C 6673522SSB048H4S (460V) TXV 45500 15.5 11.7 CH33-48C EL296UH090XE48C 6673832SSB048H4S (460V) TXV 45500 15.5 12 CH33-48C EL296UH110XE60C 6673833SSB048H4S (460V) TXV 45000 14 11 CH33-48C 6673520SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 EL296UH090XV48C 6673534SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 EL296UH090XV60C 6673535NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 40: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 40

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 EL296UH110XV48C 6673536SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 EL296UH110XV60C 6673537SSB048H4S (460V) TXV 46500 16 12 CH33-49 SL280UH090V60C 6673538SSB048H4S (460V) TXV 46500 16 12 CH33-49 SL280UH090XV60C 6673835SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 SL280UH110V60C 6673539SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 SL280UH110XV60C 6673836SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 SLP98UH090XV48C 6673540SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 SLP98UH090XV60C 6673541SSB048H4S (460V) TXV 46500 15.5 12 CH33-49 SLP98UH110XV60C 6673542SSB048H4S (460V) TXV 46000 14.5 11.5 CH33-49 6673834SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C CBWMV-60C-100 6673837SSB048H4S (460V) TXV 46000 16 12 CH33-50/60C EL180UH090E60C 6673838SSB048H4S (460V) TXV 46000 16 12 CH33-50/60C EL180UH110E60C 6673839SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL195UH090XE48C 6673544SSB048H4S (460V) TXV 46500 15.5 11.7 CH33-50/60C EL195UH110XE60C 6673545SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL296UH090XE48C 6679423SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL296UH090XE48C 6673995SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH090XV48C 6673546SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH090XV60C 6673547SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XE60C 6673996SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XE60C 6679424SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C EL296UH110XV48C 6673548SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C EL296UH110XV60C 6673549SSB048H4S (460V) TXV 46500 16 12 CH33-50/60C SL280UH090V60C 6673552SSB048H4S (460V) TXV 46500 15.5 12.2 CH33-50/60C SL280UH090XV60C 6673840SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C SL280UH110V60C 6673553SSB048H4S (460V) TXV 46000 15.5 12 CH33-50/60C SL280UH110XV60C 6673841SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH090XV48C 6673554SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH090XV60C 6673555SSB048H4S (460V) TXV 46000 15.5 11.7 CH33-50/60C SLP98UH110XV60C 6673556SSB048H4S (460V) TXV 46000 14.5 11.5 CH33-50/60C 6673543SSB048H4S (460V) TXV 46000 16 12 CH33-60D EL296UH135XV60D 6673558SSB048H4S (460V) TXV 46000 16 12 CH33-60D SL280UH135V60D 6673559SSB048H4S (460V) TXV 46000 15.5 12 CH33-60D SLP98UH135XV60D 6673560SSB048H4S (460V) TXV 45500 14 11.5 CH33-60D 6673557SSB048H4S (460V) TXV 46500 15.5 12 CH33-62D EL296UH090XV60C 8341590SSB048H4S (460V) TXV 46500 15.5 12 CH33-62D EL296UH110XV60C 8341591SSB048H4S (460V) TXV 46500 16 12 CH33-62D EL296UH135XV60D 6673562SSB048H4S (460V) TXV 46500 16 12 CH33-62D SL280UH135V60D 6673563SSB048H4S (460V) TXV 46500 16 12 CH33-62D SLP98UH135XV60D 6673564SSB048H4S (460V) TXV 46000 14.5 11.5 CH33-62D 6673561SSB048H4S (460V) TXV 44500 15 11.7 CR33-48 EL180DF110E60C 6673569SSB048H4S (460V) TXV 44000 15 11.5 CR33-48 EL195DF090XE48C 6673565NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 41: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 41

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 44500 15 11 CR33-48 EL195DF110XE60C 6673566SSB048H4S (460V) TXV 44500 15 11.5 CR33-48 EL296DF090XE48C 6673843SSB048H4S (460V) TXV 44500 15 11 CR33-48 EL296DF090XV60C 6673567SSB048H4S (460V) TXV 44500 15 11.7 CR33-48 EL296DF110XE60C 6673844SSB048H4S (460V) TXV 44500 15 11 CR33-48 EL296DF110XV60C 6673568SSB048H4S (460V) TXV 44500 15 11.7 CR33-48 SL280DF090V60C 6673570SSB048H4S (460V) TXV 44500 15.5 11.7 CR33-48 SL280DF110V60C 6673571SSB048H4S (460V) TXV 44500 15 11 CR33-48 SLP98DF090XV48C 6673845SSB048H4S (460V) TXV 44500 15 11 CR33-48 SLP98DF090XV60C 6673846SSB048H4S (460V) TXV 44500 15 11.5 CR33-48 SLP98DF110XV60C 6673847SSB048H4S (460V) TXV 44000 14 11 CR33-48 6673848SSB048H4S (460V) TXV 45000 15.5 12 CR33-50/60 EL180DF110E60C 6673851SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 EL195DF090XE48C 6673572SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 EL195DF110XE60C 6673573SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 EL296DF090XE48C 6673852SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 EL296DF090XV60C 6673574SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 EL296DF110XE60C 6673853SSB048H4S (460V) TXV 45000 15 11.5 CR33-50/60 EL296DF110XV60C 6673575SSB048H4S (460V) TXV 45000 15.5 11.7 CR33-50/60 SL280DF090V60C 6673577SSB048H4S (460V) TXV 45000 15.5 12 CR33-50/60 SL280DF110V60C 6673578SSB048H4S (460V) TXV 45000 15 11.5 CR33-50/60 SLP98DF090XV48C 6673854SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 SLP98DF090XV60C 6673855SSB048H4S (460V) TXV 45000 15 11.7 CR33-50/60 SLP98DF110XV60C 6673856SSB048H4S (460V) TXV 44500 14 11 CR33-50/60 6673850SSB048H4S (460V) TXV 44500 14 11 CR33-60 6673857SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48B EL180UH090E48B 10247904SSB048H4S (460V) TXV 46000 15.5 12 CX35-48B EL180UH090E60C 10247905SSB048H4S (460V) TXV 45500 15.5 12 CX35-48B EL180UH110E60C 10247906SSB048H4S (460V) TXV 45500 15 11.7 CX35-48B SL280UH090V48B 10247907SSB048H4S (460V) TXV 45500 14 11 CX35-48B 10247908SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-48C EL180UH090E60C 10247909SSB048H4S (460V) TXV 46500 15 11.7 CX35-48C EL180UH110E60C 10247910SSB048H4S (460V) TXV 45500 15 11.7 CX35-48C EL195UH090XE48C 10247911SSB048H4S (460V) TXV 46500 15 11.7 CX35-48C EL195UH110XE60C 10247912SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XE48C 10247913SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XV48C 10247914SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C EL296UH090XV60C 10247915SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C EL296UH110XE60C 10247916SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C EL296UH110XV48C 10247917SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C EL296UH110XV60C 10247918SSB048H4S (460V) TXV 46000 16 12 CX35-48C SL280UH090V60C 10247919SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C SL280UH090XV60C 10247920SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C SL280UH110V60C 10247921NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 42: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 42

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C SL280UH110XV60C 10247922SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C SLO185BF124/141V60 10247923SSB048H4S (460V) TXV 46000 15.5 12 CX35-48C SLO185UF124/141V60 10247924SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C SLP98UH090XV48C 10247925SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C SLP98UH090XV60C 10247926SSB048H4S (460V) TXV 46000 15.5 11.7 CX35-48C SLP98UH110XV60C 10247927SSB048H4S (460V) TXV 45500 14 11 CX35-48C 10247928SSB048H4S (460V) TXV 46500 15 12 CX35-49C EL180UH090E60C 10247929SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL180UH110E60C 10247930SSB048H4S (460V) TXV 46500 15.5 12.2 CX35-49C EL195UH090XE48C 10247931SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL195UH110XE60C 10247932SSB048H4S (460V) TXV 46500 15.5 12 CX35-49C EL296UH090XE48C 10247933SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL296UH090XV48C 10247934SSB048H4S (460V) TXV 46500 15.5 12 CX35-49C EL296UH090XV60C 10247935SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL296UH110XE60C 10247936SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL296UH110XV48C 10247937SSB048H4S (460V) TXV 46500 16 12 CX35-49C EL296UH110XV60C 10247938SSB048H4S (460V) TXV 47000 16 12 CX35-49C SL280UH090V60C 10247939SSB048H4S (460V) TXV 46500 16 12 CX35-49C SL280UH090XV60C 10247940SSB048H4S (460V) TXV 46500 16 12 CX35-49C SL280UH110V60C 10247941SSB048H4S (460V) TXV 46500 16 12 CX35-49C SL280UH110XV60C 10247942SSB048H4S (460V) TXV 46500 15.5 12.2 CX35-49C SLO185BF124/141V60 10247943SSB048H4S (460V) TXV 46500 15.5 12.2 CX35-49C SLO185UF124/141V60 10247944SSB048H4S (460V) TXV 46500 16 12 CX35-49C SLP98UH090XV48C 10247945SSB048H4S (460V) TXV 46500 16 12 CX35-49C SLP98UH090XV60C 10247946SSB048H4S (460V) TXV 46500 16 12 CX35-49C SLP98UH110XV60C 10247947SSB048H4S (460V) TXV 46500 14.5 11.7 CX35-49C 10247948SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C CBWMV-60C-100 10247949SSB048H4S (460V) TXV 45500 15.5 12 CX35-50/60C EL180UH090E60C 10247950SSB048H4S (460V) TXV 45000 15 11.7 CX35-50/60C EL180UH110E60C 10254151SSB048H4S (460V) TXV 45000 15 11.7 CX35-50/60C EL195UH090XE48C 10247951SSB048H4S (460V) TXV 45500 15 11.7 CX35-50/60C EL195UH110XE60C 10247952SSB048H4S (460V) TXV 45500 15 11.7 CX35-50/60C EL296UH090XE48C 10247953SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH090XV48C 10247954SSB048H4S (460V) TXV 45500 15 11.7 CX35-50/60C EL296UH090XV60C 10247955SSB048H4S (460V) TXV 45500 15.5 12 CX35-50/60C EL296UH110XE60C 10247956SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH110XV48C 10247957SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C EL296UH110XV60C 10247958SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH090V60C 10247959SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH090XV60C 10247960SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH110V60C 10250510SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SL280UH110XV60C 10247961SSB048H4S (460V) TXV 45000 15 11.7 CX35-50/60C SLO185BF124/141V60 10247962NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 43: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 43

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB048H4S (460V) TXV 45000 15 11.7 CX35-50/60C SLO185UF124/141V60 10247963SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH090XV48C 10247964SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH090XV60C 10247965SSB048H4S (460V) TXV 45500 15.5 11.7 CX35-50/60C SLP98UH110XV60C 10247966SSB048H4S (460V) TXV 45000 14 11 CX35-50/60C 10247967SSB048H4S (460V) TXV 47000 16 12.5 CX35-60C EL180UH090E60C 10247968SSB048H4S (460V) TXV 47000 16 12.5 CX35-60C EL180UH110XE60C 10247969SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL195UH090XE48C 10247970SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL195UH110XE60C 10247971SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL296UH090XE48C 10247972SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL296UH090XV48C 10247973SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL296UH090XV60C 10247974SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL296UH110XE60C 10247975SSB048H4S (460V) TXV 47000 16 12 CX35-60C EL296UH110XV48C 10247976SSB048H4S (460V) TXV 47500 16 12 CX35-60C EL296UH110XV60C 10247977SSB048H4S (460V) TXV 47500 16.5 12.2 CX35-60C SL280UH090V60C 10247978SSB048H4S (460V) TXV 47000 16 12 CX35-60C SL280UH090XV60C 10247979SSB048H4S (460V) TXV 47000 16 12 CX35-60C SL280UH110V60C 10247980SSB048H4S (460V) TXV 47000 16 12 CX35-60C SL280UH110XV60C 10247981SSB048H4S (460V) TXV 47000 16 12 CX35-60C SLO185BF124/141V60 10247982SSB048H4S (460V) TXV 47000 16 12 CX35-60C SLO185UF124/141V60 10247983SSB048H4S (460V) TXV 47000 16 12 CX35-60C SLP98UH090XV48C 10247984SSB048H4S (460V) TXV 47000 16 12 CX35-60C SLP98UH090XV60C 10247985SSB048H4S (460V) TXV 47500 16 12 CX35-60C SLP98UH110XV60C 10247986SSB048H4S (460V) TXV 47000 14.5 11.7 CX35-60C 10247987SSB048H4S (460V) TXV 47000 16 12 CX35-60D EL296UH135XV60D 10247988SSB048H4S (460V) TXV 47000 16 12 CX35-60D SL280UH135V60D 10247989SSB048H4S (460V) TXV 46500 15.5 12.2 CX35-60D SLO185BF124/141V60 10247990SSB048H4S (460V) TXV 46500 15.5 12.2 CX35-60D SLO185UF124/141V60 10247991SSB048H4S (460V) TXV 47000 16 12 CX35-60D SLP98UH135XV60D 10247992SSB048H4S (460V) TXV 46500 14.5 11 CX35-60D 10247993SSB048H4S (460V) TXV 47500 16.5 12.2 CX38-62C SL280UH090V60C 10556029SSB060H4S (208/230V) TXV 55500 15 12 C35-49C EL180UH090E60C 10248312SSB060H4S (208/230V) TXV 56500 15 12 C35-49C EL180UH110XE60C 10248313SSB060H4S (208/230V) TXV 56500 15 12 C35-49C EL195UH110XE60C 10248315SSB060H4S (208/230V) TXV 56500 15 11 C35-49C EL296UH090XV60C 10248316SSB060H4S (208/230V) TXV 56500 15 12 C35-49C EL296UH110XE60C 10248317SSB060H4S (208/230V) TXV 56000 15 11 C35-49C EL296UH110XV60C 10248318SSB060H4S (208/230V) TXV 56500 15 11.7 C35-49C SL280UH090V60C 10248319SSB060H4S (208/230V) TXV 56500 15 11.7 C35-49C SL280UH090XV60C 10248320SSB060H4S (208/230V) TXV 56500 15 11.7 C35-49C SL280UH110V60C 10248321SSB060H4S (208/230V) TXV 56500 15 11.7 C35-49C SL280UH110XV60C 10248322SSB060H4S (208/230V) TXV 56500 15 11 C35-49C SLP98UH090XV60C 10248323NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 44: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 44

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (208/230V) TXV 56500 15 11 C35-49C SLP98UH110XV60C 10248324SSB060H4S (208/230V) TXV 56500 14 11 C35-49C 10248325SSB060H4S (208/230V) TXV 54000 14.5 11 C35-50/60C CBWMV-60C-120 10248326SSB060H4S (208/230V) TXV 55000 15 11.7 C35-50/60C EL180UH090E60C 10248327SSB060H4S (208/230V) TXV 55000 14.5 11.7 C35-50/60C EL180UH110E60C 10248328SSB060H4S (208/230V) TXV 55000 14.5 11.7 C35-50/60C EL180UH110XE60C 10248329SSB060H4S (208/230V) TXV 55000 15 11.7 C35-50/60C EL195UH110XE60C 10248331SSB060H4S (208/230V) TXV 55000 15 11.7 C35-50/60C EL296UH110XE60C 10248333SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C EL296UH110XV60C 10248334SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C SL280UH090V60C 10248332SSB060H4S (208/230V) TXV 55000 15 11 C35-50/60C SL280UH090XV60C 10248335SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C SL280UH110V60C 10248336SSB060H4S (208/230V) TXV 54500 14.5 11 C35-50/60C SL280UH110XV60C 10248337SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C SL296UH090XV60C 10250491SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C SLP98UH090XV60C 10248338SSB060H4S (208/230V) TXV 55000 14.5 11 C35-50/60C SLP98UH110XV60C 10248339SSB060H4S (208/230V) TXV 55000 14 11 C35-50/60C 10248340SSB060H4S (208/230V) TXV 57500 15.5 12.2 C35-60C EL180UH090E60C 10248341SSB060H4S (208/230V) TXV 57500 15.5 12.2 C35-60C EL180UH110E60C 10248342SSB060H4S (208/230V) TXV 57500 15.5 12.2 C35-60C EL180UH110XE60C 10248344SSB060H4S (208/230V) TXV 57500 15.5 12.2 C35-60C EL195UH110XE60C 10248345SSB060H4S (208/230V) TXV 56500 15 11.7 C35-60C EL296UH090XV60C 10248346SSB060H4S (208/230V) TXV 57500 15.5 12.2 C35-60C EL296UH110XE60C 10248347SSB060H4S (208/230V) TXV 56500 15 11.7 C35-60C EL296UH110XV60C 10248348SSB060H4S (208/230V) TXV 57500 16 12 C35-60C SL280UH090V60C 10248349SSB060H4S (208/230V) TXV 57500 15.5 12 C35-60C SL280UH090XV60C 10248350SSB060H4S (208/230V) TXV 57500 15.5 11.7 C35-60C SL280UH110V60C 10248351SSB060H4S (208/230V) TXV 57500 15.5 11.7 C35-60C SL280UH110XV60C 10248352SSB060H4S (208/230V) TXV 57000 15 11.7 C35-60C SLO185B124/141V60 10248353SSB060H4S (208/230V) TXV 57500 15.5 11.7 C35-60C SLP98UH090XV60C 10248354SSB060H4S (208/230V) TXV 57000 15.5 11.7 C35-60C SLP98UH110XV60C 10248355SSB060H4S (208/230V) TXV 57500 14.5 11.7 C35-60C 10248356SSB060H4S (208/230V) TXV 57000 15.5 12 C35-60D EL180UH135E60D 10248357SSB060H4S (208/230V) TXV 57000 15 11.7 C35-60D EL195UH135XE60D 10248358SSB060H4S (208/230V) TXV 56500 15 11.7 C35-60D EL296UH135XE60D 10248359SSB060H4S (208/230V) TXV 57000 15.5 11.7 C35-60D EL296UH135XV60D 10248360SSB060H4S (208/230V) TXV 57000 15.5 12 C35-60D SL280UH135V60D 10250492SSB060H4S (208/230V) TXV 57000 15 11.7 C35-60D SLO185BF124/141V60 10248361SSB060H4S (208/230V) TXV 56000 15 11.7 C35-60D SLO185UF124/141V60 10248362SSB060H4S (208/230V) TXV 57000 15.5 12 C35-60D SLP98UH135XV60D 10248363SSB060H4S (208/230V) TXV 56500 14 11 C35-60D 10248364SSB060H4S (208/230V) TXV 56000 15.1 11.7 CBA27UHE-060 10259524SSB060H4S (208/230V) TXV 56500 14.5 11.7 CBX25UH-060 6564423NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 45: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 45

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (208/230V) TXV 56500 15.5 12 CBX27UH-060 6564229SSB060H4S (208/230V) TXV 56500 14.5 11.7 CBX32M-060 6564230SSB060H4S (208/230V) TXV 56000 15.5 11.7 CBX32MV-048 6564231SSB060H4S (208/230V) TXV 56500 15.5 11.7 CBX32MV-060 6564232SSB060H4S (208/230V) TXV 56500 15.5 12.2 CBX32MV-068 6564233SSB060H4S (208/230V) TXV 55000 15 11.7 CBX40UHV-048 6564424SSB060H4S (208/230V) TXV 55500 15 11.7 CBX40UHV-060 6564425SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL180UH090E60C 6564427SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL180UH110E60C 6564428SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL195UH110XE60C 6564235SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL296UH090XV60C 6564236SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL296UH110XE60C 6564429SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 EL296UH110XV60C 6564237SSB060H4S (208/230V) TXV 54500 15 11 CH23-65 EL296UH135XV60D 6564238SSB060H4S (208/230V) TXV 54500 15 11 CH23-65 SL280UH090V60C 6564241SSB060H4S (208/230V) TXV 54500 15 11 CH23-65 SL280UH090XV60C 6603272SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 SL280UH110XV60C 6564242SSB060H4S (208/230V) TXV 54500 15 11 CH23-65 SL280UH135V60D 9150364SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 SLP98UH090XV60C 6564244SSB060H4S (208/230V) TXV 54000 14.5 11 CH23-65 SLP98UH110XV60C 6564245SSB060H4S (208/230V) TXV 54500 15 11 CH23-65 SLP98UH135XV60D 6564246SSB060H4S (208/230V) TXV 54500 15 11 CH23-68 EL180UH135E60D 6564431SSB060H4S (208/230V) TXV 57000 15 11.7 CH23-68 EL195UH135XE60D 6564248SSB060H4S (208/230V) TXV 54500 14.5 11 CH23-68 EL296UH135XE60D 6564430SSB060H4S (208/230V) TXV 57500 15.5 12 CH23-68 EL296UH135XV60D 6564249SSB060H4S (208/230V) TXV 57500 15.5 12 CH23-68 SL280UH135V60D 6564251SSB060H4S (208/230V) TXV 57000 15.5 12 CH23-68 SLP98UH135XV60D 6564252SSB060H4S (208/230V) TXV 57500 14.5 11.7 CH23-68 6564247SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-50/60C EL180UH090E60C 6564434SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-50/60C EL180UH110E60C 6564435SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-50/60C EL180UH110XE60C 6564436SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-50/60C EL195UH110XE60C 6564255SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C EL296UH090XV60C 6564256SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-50/60C EL296UH110XE60C 6564437SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C EL296UH110XV60C 6564257SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C SL280UH090V60C 6564260SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C SL280UH090XV60C 6564433SSB060H4S (208/230V) TXV 56000 14.5 11 CH33-50/60C SL280UH110V60C 6564261SSB060H4S (208/230V) TXV 55500 15 11.7 CH33-50/60C SL280UH110XV60C 6564432SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C SLP98UH090XV60C 6564262SSB060H4S (208/230V) TXV 56000 15 11 CH33-50/60C SLP98UH110XV60C 6564263SSB060H4S (208/230V) TXV 56000 14 11 CH33-50/60C 6564253SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-60D CBWMV-60C-100 6564265NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 46: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 46

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (208/230V) TXV 56000 15 11 CH33-60D EL195UH135XE60D 6564266SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-60D EL296UH135XV60D 6564267SSB060H4S (208/230V) TXV 56000 15 11.7 CH33-60D SL280UH135V60D 6564269SSB060H4S (208/230V) TXV 56000 15.5 11.7 CH33-60D SLP98UH135XV60D 6564270SSB060H4S (208/230V) TXV 55500 14 11 CH33-60D 6564264SSB060H4S (208/230V) TXV 56500 15.5 11.7 CH33-62D EL180UH135E60D 6564439SSB060H4S (208/230V) TXV 56500 15 11.7 CH33-62D EL195UH135XE60D 6564272SSB060H4S (208/230V) TXV 56000 15 11.5 CH33-62D EL296UH090XV60C 8341592SSB060H4S (208/230V) TXV 56000 15 11.5 CH33-62D EL296UH110XV60C 8341593SSB060H4S (208/230V) TXV 56500 15 11.7 CH33-62D EL296UH135XE60D 6564438SSB060H4S (208/230V) TXV 56500 15 11.7 CH33-62D EL296UH135XV60D 6564273SSB060H4S (208/230V) TXV 56000 15 12 CH33-62D SL280UH090V60C 6564275SSB060H4S (208/230V) TXV 56500 15.5 11.7 CH33-62D SL280UH090XV60C 6564440SSB060H4S (208/230V) TXV 56000 15 12 CH33-62D SL280UH110V60C 6564276SSB060H4S (208/230V) TXV 56500 15.5 11.7 CH33-62D SL280UH135V60D 6564277SSB060H4S (208/230V) TXV 56500 15.5 11.7 CH33-62D SLP98UH135XV60D 6564278SSB060H4S (208/230V) TXV 56000 14 11 CH33-62D 6564271SSB060H4S (208/230V) TXV 54000 14.5 11 CR33-50/60 SLP98DF090XV60C 6564441SSB060H4S (208/230V) TXV 54000 14.5 11 CR33-50/60 SLP98DF110XV60C 6564443SSB060H4S (208/230V) TXV 54500 14.5 11 CR33-60 EL296DF090XV60C 6564280SSB060H4S (208/230V) TXV 54500 14.5 11 CR33-60 EL296DF110XV60C 6564281SSB060H4S (208/230V) TXV 54000 14.5 11 CR33-60 SLP98DF090XV60C 6564442SSB060H4S (208/230V) TXV 54000 14.5 11 CR33-60 SLP98DF110XV60C 6564444SSB060H4S (208/230V) TXV 55000 14 11 CR33-60 6564279SSB060H4S (208/230V) TXV 56000 15 11.7 CX35-48C EL180UH090E60C 10248365SSB060H4S (208/230V) TXV 55500 15 11.7 CX35-48C EL180UH110E60C 10248366SSB060H4S (208/230V) TXV 55500 15 11.7 CX35-48C EL180UH110XE60C 10248367SSB060H4S (208/230V) TXV 55500 15 11.7 CX35-48C EL195UH110XE60C 10248368SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C EL296UH090XV60C 10248369SSB060H4S (208/230V) TXV 55500 15 11.7 CX35-48C EL296UH110XE60C 10248370SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C EL296UH110XV60C 10248371SSB060H4S (208/230V) TXV 56000 15 11.5 CX35-48C SL280UH090V60C 10248372SSB060H4S (208/230V) TXV 56000 15 11.5 CX35-48C SL280UH090XV60C 10248373SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C SL280UH110V60C 10250493SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C SL280UH110XV60C 10248374SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C SLP98UH090XV60C 10250494SSB060H4S (208/230V) TXV 55500 15 11 CX35-48C SLP98UH110XV60C 10248376SSB060H4S (208/230V) TXV 55500 14 11 CX35-48C 10248377SSB060H4S (208/230V) TXV 56500 15 12 CX35-49C EL180UH090E60C 10248378SSB060H4S (208/230V) TXV 56500 15 12 CX35-49C EL180UH110E60C 10248379SSB060H4S (208/230V) TXV 56500 15 12 CX35-49C EL180UH110XE60C 10248380SSB060H4S (208/230V) TXV 56500 15 12 CX35-49C EL195UH110XE60C 10248381SSB060H4S (208/230V) TXV 56500 15 11 CX35-49C EL296UH090XV60C 10248382NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 47: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 47

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (208/230V) TXV 56500 15 12 CX35-49C EL296UH110XE60C 10248383SSB060H4S (208/230V) TXV 56000 15 11 CX35-49C EL296UH110XV60C 10248384SSB060H4S (208/230V) TXV 56500 15 11.7 CX35-49C SL280UH090V60C 10248385SSB060H4S (208/230V) TXV 56500 15 11.7 CX35-49C SL280UH090XV60C 10248386SSB060H4S (208/230V) TXV 56500 15 11.7 CX35-49C SL280UH110V60C 10250495SSB060H4S (208/230V) TXV 56500 15 11.7 CX35-49C SL280UH110XV60C 10248387SSB060H4S (208/230V) TXV 56500 15 11 CX35-49C SLP98UH090XV60C 10248389SSB060H4S (208/230V) TXV 56000 15 11 CX35-49C SLP98UH110XV60C 10248390SSB060H4S (208/230V) TXV 56500 14 11 CX35-49C 10248391SSB060H4S (208/230V) TXV 54000 14.5 11 CX35-50/60C CBWMV-60C-120 10250496SSB060H4S (208/230V) TXV 55000 15 11.7 CX35-50/60C EL180UH090E60C 10248392SSB060H4S (208/230V) TXV 55000 14.5 11.7 CX35-50/60C EL180UH110E60C 10248393SSB060H4S (208/230V) TXV 55000 14.5 11.7 CX35-50/60C EL180UH110XE60C 10248394SSB060H4S (208/230V) TXV 55000 15 11.7 CX35-50/60C EL195UH110XE60C 10248395SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C EL296UH090XV60C 10248396SSB060H4S (208/230V) TXV 55000 15 11.7 CX35-50/60C EL296UH110XE60C 10248397SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C EL296UH110XV60C 10248398SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C SL280UH090V60C 10248399SSB060H4S (208/230V) TXV 55000 15 11 CX35-50/60C SL280UH090XV60C 10248400SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C SL280UH110V60C 10250497SSB060H4S (208/230V) TXV 54500 14.5 11 CX35-50/60C SL280UH110XV60C 10248401SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C SLP98UH090XV60C 10250498SSB060H4S (208/230V) TXV 55000 14.5 11 CX35-50/60C SLP98UH110XV60C 10250499SSB060H4S (208/230V) TXV 57500 15.5 12.2 CX35-60C EL180UH090E60C 10248402SSB060H4S (208/230V) TXV 57500 15.5 12.2 CX35-60C EL180UH110E60C 10248403SSB060H4S (208/230V) TXV 57500 15.5 12.2 CX35-60C EL180UH110XE60C 10248404SSB060H4S (208/230V) TXV 57500 15.5 12.2 CX35-60C EL195UH110XE60C 10248405SSB060H4S (208/230V) TXV 57500 15.5 11.7 CX35-60C EL296UH090XV60C 10248406SSB060H4S (208/230V) TXV 57500 15.5 12.2 CX35-60C EL296UH110XE60C 10248407SSB060H4S (208/230V) TXV 57000 15.5 11.7 CX35-60C EL296UH110XV60C 10248408SSB060H4S (208/230V) TXV 57500 16 12 CX35-60C SL280UH090V60C 10248409SSB060H4S (208/230V) TXV 57500 15.5 12 CX35-60C SL280UH090XV60C 10248410SSB060H4S (208/230V) TXV 57500 15.5 11.7 CX35-60C SL280UH110V60C 10250500SSB060H4S (208/230V) TXV 57500 15 11.7 CX35-60C SL280UH110XV60C 10248411SSB060H4S (208/230V) TXV 57000 15 11.7 CX35-60C SLO185B124/141V60 10248412SSB060H4S (208/230V) TXV 57500 15.5 11.7 CX35-60C SLP98UH090XV60C 10248413SSB060H4S (208/230V) TXV 57000 15.5 11.7 CX35-60C SLP98UH110XV60C 10248414SSB060H4S (208/230V) TXV 57500 14.5 11.7 CX35-60C 10248415SSB060H4S (208/230V) TXV 57000 15.5 12 CX35-60D EL180UH135E60D 10248417SSB060H4S (208/230V) TXV 57000 15 11.7 CX35-60D EL195UH135XE60D 10248418SSB060H4S (208/230V) TXV 57000 15 11.7 CX35-60D EL296UH135XE60D 10248419SSB060H4S (208/230V) TXV 57000 15.5 11.7 CX35-60D EL296UH135XV60D 10248420SSB060H4S (208/230V) TXV 57000 15.5 12 CX35-60D SL280UH135V60D 10250501NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 48: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 48

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (208/230V) TXV 57000 15 11.7 CX35-60D SLO185BF124/141V60 10248421SSB060H4S (208/230V) TXV 56000 15 11.7 CX35-60D SLO185UF124/141V60 10248422SSB060H4S (208/230V) TXV 57000 15.5 12 CX35-60D SLP98UH135XV60D 10248423SSB060H4S (208/230V) TXV 56500 14 11 CX35-60D 10248424SSB060H4S (208/230V) TXV 57500 15.5 12 CX38-62C SL280UH090XV60C 10556094SSB060H4S (460V) TXV 55500 15 12 C35-49C EL180UH090E60C 10248186SSB060H4S (460V) TXV 56500 15 12 C35-49C EL180UH110XE60C 10248187SSB060H4S (460V) TXV 56500 15 12 C35-49C EL195UH110XE60C 10248188SSB060H4S (460V) TXV 56500 15 11 C35-49C EL296UH090XV60C 10248189SSB060H4S (460V) TXV 56500 15 12 C35-49C EL296UH110XE60C 10248190SSB060H4S (460V) TXV 56000 15 11 C35-49C EL296UH110XV60C 10248191SSB060H4S (460V) TXV 56500 15 11.7 C35-49C SL280UH090V60C 10248192SSB060H4S (460V) TXV 56500 15 11.7 C35-49C SL280UH090XV60C 10248193SSB060H4S (460V) TXV 56500 15 11.7 C35-49C SL280UH110V60C 10248194SSB060H4S (460V) TXV 56500 15 11.7 C35-49C SL280UH110XV60C 10248195SSB060H4S (460V) TXV 56500 15 11 C35-49C SLP98UH090XV60C 10248196SSB060H4S (460V) TXV 56500 15 11 C35-49C SLP98UH110XV60C 10248197SSB060H4S (460V) TXV 56500 14 11 C35-49C 10248198SSB060H4S (460V) TXV 54000 14.5 11 C35-50/60C CBWMV-60C-120 10248199SSB060H4S (460V) TXV 55000 15 11.7 C35-50/60C EL180UH090E60C 10248200SSB060H4S (460V) TXV 55000 14.5 11.7 C35-50/60C EL180UH110E60C 10248201SSB060H4S (460V) TXV 55000 14.5 11.7 C35-50/60C EL180UH110XE60C 10248202SSB060H4S (460V) TXV 55000 15 11.7 C35-50/60C EL195UH110XE60C 10248203SSB060H4S (460V) TXV 55000 15 11.7 C35-50/60C EL296UH110XE60C 10248205SSB060H4S (460V) TXV 55000 14.5 11 C35-50/60C EL296UH110XV60C 10248206SSB060H4S (460V) TXV 55000 14.5 11 C35-50/60C SL280UH090V60C 10248204SSB060H4S (460V) TXV 55000 15 11 C35-50/60C SL280UH090XV60C 10248207SSB060H4S (460V) TXV 55000 14.5 11 C35-50/60C SL280UH110V60C 10248208SSB060H4S (460V) TXV 54500 14.5 11 C35-50/60C SL280UH110XV60C 10248209SSB060H4S (460V) TXV 55000 14.5 11 C35-50/60C SLP98UH090XV60C 10248210SSB060H4S (460V) TXV 55000 14.5 11 C35-50/60C SLP98UH110XV60C 10248211SSB060H4S (460V) TXV 55000 14 11 C35-50/60C 10248212SSB060H4S (460V) TXV 57500 15.5 12.2 C35-60C EL180UH090E60C 10248213SSB060H4S (460V) TXV 57500 15.5 12.2 C35-60C EL180UH110E60C 10248214SSB060H4S (460V) TXV 57500 15.5 12.2 C35-60C EL180UH110XE60C 10248215SSB060H4S (460V) TXV 57500 15.5 12.2 C35-60C EL195UH110XE60C 10248216SSB060H4S (460V) TXV 56500 15 11.7 C35-60C EL296UH090XV60C 10248217SSB060H4S (460V) TXV 57500 15.5 12.2 C35-60C EL296UH110XE60C 10248218SSB060H4S (460V) TXV 56500 15 11.7 C35-60C EL296UH110XV60C 10248219SSB060H4S (460V) TXV 57500 16 12 C35-60C SL280UH090V60C 10248220SSB060H4S (460V) TXV 57500 15.5 12 C35-60C SL280UH090XV60C 10248221SSB060H4S (460V) TXV 57500 15.5 11.7 C35-60C SL280UH110V60C 10248222SSB060H4S (460V) TXV 57500 15.5 11.7 C35-60C SL280UH110XV60C 10248223NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 49: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 49

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (460V) TXV 57000 15 11.7 C35-60C SLO185B124/141V60 10248224SSB060H4S (460V) TXV 57500 15.5 11.7 C35-60C SLP98UH090XV60C 10248225SSB060H4S (460V) TXV 57000 15.5 11.7 C35-60C SLP98UH110XV60C 10248226SSB060H4S (460V) TXV 57500 14.5 11.7 C35-60C 10248227SSB060H4S (460V) TXV 57000 15.5 12 C35-60D EL180UH135E60D 10248228SSB060H4S (460V) TXV 57000 15 11.7 C35-60D EL195UH135XE60D 10248229SSB060H4S (460V) TXV 56500 15 11.7 C35-60D EL296UH135XE60D 10248230SSB060H4S (460V) TXV 57000 15.5 11.7 C35-60D EL296UH135XV60D 10248231SSB060H4S (460V) TXV 57000 15.5 12 C35-60D SL280UH135V60D 10250485SSB060H4S (460V) TXV 57000 15 11.7 C35-60D SLO185BF124/141V60 10248232SSB060H4S (460V) TXV 56000 15 11.7 C35-60D SLO185UF124/141V60 10248233SSB060H4S (460V) TXV 57000 15.5 12 C35-60D SLP98UH135XV60D 10250486SSB060H4S (460V) TXV 56500 14 11 C35-60D 10248234SSB060H4S (460V) TXV 56000 15.1 11.7 CBA27UHE-060 10259525SSB060H4S (460V) TXV 56500 14.5 11.7 CBX25UH-060 6564642SSB060H4S (460V) TXV 56500 15.5 12 CBX27UH-060 6564448SSB060H4S (460V) TXV 56500 14.5 11.7 CBX32M-060 6564449SSB060H4S (460V) TXV 56000 15.5 11.7 CBX32MV-048 6564450SSB060H4S (460V) TXV 56500 15.5 11.7 CBX32MV-060 6564451SSB060H4S (460V) TXV 56500 15.5 12.2 CBX32MV-068 6564452SSB060H4S (460V) TXV 55000 15 11.7 CBX40UHV-048 6564643SSB060H4S (460V) TXV 55500 15 11.7 CBX40UHV-060 6564644SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL180UH090E60C 6564646SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL180UH110E60C 6564647SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL195UH110XE60C 6564454SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL296UH090XV60C 6564455SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL296UH110XE60C 6564648SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 EL296UH110XV60C 6564456SSB060H4S (460V) TXV 54500 15 11 CH23-65 EL296UH135XV60D 6564457SSB060H4S (460V) TXV 54500 15 11 CH23-65 SL280UH090V60C 6564460SSB060H4S (460V) TXV 54500 15 11 CH23-65 SL280UH090XV60C 6603273SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 SL280UH110XV60C 6564461SSB060H4S (460V) TXV 54500 15 11 CH23-65 SL280UH135V60D 9150365SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 SLP98UH090XV60C 6564463SSB060H4S (460V) TXV 54000 14.5 11 CH23-65 SLP98UH110XV60C 6564464SSB060H4S (460V) TXV 54500 15 11 CH23-65 SLP98UH135XV60D 6564465SSB060H4S (460V) TXV 54500 15 11 CH23-68 EL180UH135E60D 6564650SSB060H4S (460V) TXV 57000 15 11.7 CH23-68 EL195UH135XE60D 6564467SSB060H4S (460V) TXV 54500 14.5 11 CH23-68 EL296UH135XE60D 6564649SSB060H4S (460V) TXV 57500 15.5 12 CH23-68 EL296UH135XV60D 6564468SSB060H4S (460V) TXV 57500 15.5 12 CH23-68 SL280UH135V60D 6564470SSB060H4S (460V) TXV 57000 15.5 12 CH23-68 SLP98UH135XV60D 6564471SSB060H4S (460V) TXV 57500 14.5 11.7 CH23-68 6564466NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 50: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 50

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (460V) TXV 56000 15 11.7 CH33-50/60C EL180UH090E60C 6564653SSB060H4S (460V) TXV 56000 15 11.7 CH33-50/60C EL180UH110E60C 6564654SSB060H4S (460V) TXV 56000 15 11.7 CH33-50/60C EL180UH110XE60C 6564655SSB060H4S (460V) TXV 56000 15 11.7 CH33-50/60C EL195UH110XE60C 6564474SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C EL296UH090XV60C 6564475SSB060H4S (460V) TXV 56000 15 11.7 CH33-50/60C EL296UH110XE60C 6564656SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C EL296UH110XV60C 6564476SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C SL280UH090V60C 6564479SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C SL280UH090XV60C 6564652SSB060H4S (460V) TXV 56000 14.5 11 CH33-50/60C SL280UH110V60C 6564480SSB060H4S (460V) TXV 55500 15 11.7 CH33-50/60C SL280UH110XV60C 6564651SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C SLP98UH090XV60C 6564481SSB060H4S (460V) TXV 56000 15 11 CH33-50/60C SLP98UH110XV60C 6564482SSB060H4S (460V) TXV 56000 14 11 CH33-50/60C 6564472SSB060H4S (460V) TXV 56000 15 11.7 CH33-60D CBWMV-60C-100 6564484SSB060H4S (460V) TXV 56000 15 11 CH33-60D EL195UH135XE60D 6564485SSB060H4S (460V) TXV 56000 15 11.7 CH33-60D EL296UH135XV60D 6564486SSB060H4S (460V) TXV 56000 15 11.7 CH33-60D SL280UH135V60D 6564488SSB060H4S (460V) TXV 56000 15.5 11.7 CH33-60D SLP98UH135XV60D 6564489SSB060H4S (460V) TXV 55500 14 11 CH33-60D 6564483SSB060H4S (460V) TXV 56500 15.5 11.7 CH33-62D EL180UH135E60D 6564658SSB060H4S (460V) TXV 56500 15 11.7 CH33-62D EL195UH135XE60D 6564491SSB060H4S (460V) TXV 56000 15 11.5 CH33-62D EL296UH090XV60C 8341594SSB060H4S (460V) TXV 56000 15 11.5 CH33-62D EL296UH110XV60C 8341595SSB060H4S (460V) TXV 56500 15 11.7 CH33-62D EL296UH135XE60D 6564657SSB060H4S (460V) TXV 56500 15 11.7 CH33-62D EL296UH135XV60D 6564492SSB060H4S (460V) TXV 56000 15 12 CH33-62D SL280UH090V60C 6564494SSB060H4S (460V) TXV 56500 15.5 11.7 CH33-62D SL280UH090XV60C 6564659SSB060H4S (460V) TXV 56000 15 12 CH33-62D SL280UH110V60C 6564495SSB060H4S (460V) TXV 56500 15.5 11.7 CH33-62D SL280UH135V60D 6564496SSB060H4S (460V) TXV 56500 15.5 11.7 CH33-62D SLP98UH135XV60D 6564497SSB060H4S (460V) TXV 56000 14 11 CH33-62D 6564490SSB060H4S (460V) TXV 54000 14.5 11 CR33-50/60 SLP98DF090XV60C 6564660SSB060H4S (460V) TXV 54000 14.5 11 CR33-50/60 SLP98DF110XV60C 6564662SSB060H4S (460V) TXV 54500 14.5 11 CR33-60 EL296DF090XV60C 6564499SSB060H4S (460V) TXV 54500 14.5 11 CR33-60 EL296DF110XV60C 6564500SSB060H4S (460V) TXV 54000 14.5 11 CR33-60 SLP98DF090XV60C 6564661SSB060H4S (460V) TXV 54000 14.5 11 CR33-60 SLP98DF110XV60C 6564663SSB060H4S (460V) TXV 55000 14 11 CR33-60 6564498SSB060H4S (460V) TXV 56000 15 11.7 CX35-48C EL180UH090E60C 10248235SSB060H4S (460V) TXV 55500 15 11.7 CX35-48C EL180UH110E60C 10248236SSB060H4S (460V) TXV 55500 15 11.7 CX35-48C EL180UH110XE60C 10248237SSB060H4S (460V) TXV 55500 15 11.7 CX35-48C EL195UH110XE60C 10248238NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 51: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 51

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (460V) TXV 55500 15 11 CX35-48C EL296UH090XV60C 10248239SSB060H4S (460V) TXV 55500 15 11.7 CX35-48C EL296UH110XE60C 10248240SSB060H4S (460V) TXV 55500 15 11 CX35-48C EL296UH110XV60C 10248241SSB060H4S (460V) TXV 56000 15 11.5 CX35-48C SL280UH090V60C 10248242SSB060H4S (460V) TXV 56000 15 11.5 CX35-48C SL280UH090XV60C 10248243SSB060H4S (460V) TXV 55500 15 11 CX35-48C SL280UH110V60C 10250487SSB060H4S (460V) TXV 55500 15 11 CX35-48C SL280UH110XV60C 10248244SSB060H4S (460V) TXV 55500 15 11 CX35-48C SLP98UH090XV60C 10248245SSB060H4S (460V) TXV 55500 15 11 CX35-48C SLP98UH110XV60C 10248246SSB060H4S (460V) TXV 55500 14 11 CX35-48C 10248247SSB060H4S (460V) TXV 56500 15 12 CX35-49C EL180UH090E60C 10248248SSB060H4S (460V) TXV 56500 15 12 CX35-49C EL180UH110E60C 10248249SSB060H4S (460V) TXV 56500 15 12 CX35-49C EL180UH110XE60C 10248250SSB060H4S (460V) TXV 56500 15 12 CX35-49C EL195UH110XE60C 10248251SSB060H4S (460V) TXV 56500 15 11 CX35-49C EL296UH090XV60C 10248252SSB060H4S (460V) TXV 56500 15 12 CX35-49C EL296UH110XE60C 10248253SSB060H4S (460V) TXV 56000 15 11 CX35-49C EL296UH110XV60C 10248254SSB060H4S (460V) TXV 56500 15 11.7 CX35-49C SL280UH090V60C 10248255SSB060H4S (460V) TXV 56500 15 11.7 CX35-49C SL280UH090XV60C 10248256SSB060H4S (460V) TXV 56500 15 11.7 CX35-49C SL280UH110V60C 10248257SSB060H4S (460V) TXV 56500 15 11.7 CX35-49C SL280UH110XV60C 10248258SSB060H4S (460V) TXV 56500 15 11 CX35-49C SLP98UH090XV60C 10248259SSB060H4S (460V) TXV 56000 15 11 CX35-49C SLP98UH110XV60C 10248260SSB060H4S (460V) TXV 56500 14 11 CX35-49C 10248261SSB060H4S (460V) TXV 54000 14.5 11 CX35-50/60C CBWMV-60C-120 10250488SSB060H4S (460V) TXV 55000 15 11.7 CX35-50/60C EL180UH090E60C 10248262SSB060H4S (460V) TXV 55000 14.5 11.7 CX35-50/60C EL180UH110E60C 10248263SSB060H4S (460V) TXV 55000 14.5 11.7 CX35-50/60C EL180UH110XE60C 10248264SSB060H4S (460V) TXV 55000 15 11.7 CX35-50/60C EL195UH110XE60C 10248265SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C EL296UH090XV60C 10248266SSB060H4S (460V) TXV 55000 15 11.7 CX35-50/60C EL296UH110XE60C 10248267SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C EL296UH110XV60C 10248268SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C SL280UH090V60C 10248269SSB060H4S (460V) TXV 55000 15 11 CX35-50/60C SL280UH090XV60C 10248271SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C SL280UH110V60C 10248272SSB060H4S (460V) TXV 54500 14.5 11 CX35-50/60C SL280UH110XV60C 10248273SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C SLP98UH090XV60C 10248274SSB060H4S (460V) TXV 55000 14.5 11 CX35-50/60C SLP98UH110XV60C 10248275SSB060H4S (460V) TXV 57500 15.5 12.2 CX35-60C EL180UH090E60C 10248276SSB060H4S (460V) TXV 57500 15.5 12.2 CX35-60C EL180UH110E60C 10248277SSB060H4S (460V) TXV 57500 15.5 12.2 CX35-60C EL180UH110XE60C 10248278SSB060H4S (460V) TXV 57500 15.5 12.2 CX35-60C EL195UH110XE60C 10248279SSB060H4S (460V) TXV 57500 15.5 11.7 CX35-60C EL296UH090XV60C 10248280NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 52: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

SSB − 3 to 5 Ton R−410A Air Conditioner / Page 52

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

SSB060H4S (460V) TXV 57500 15.5 12.2 CX35-60C EL296UH110XE60C 10248281SSB060H4S (460V) TXV 57000 15.5 11.7 CX35-60C EL296UH110XV60C 10248282SSB060H4S (460V) TXV 57500 16 12 CX35-60C SL280UH090V60C 10248283SSB060H4S (460V) TXV 57500 15.5 12 CX35-60C SL280UH090XV60C 10248285SSB060H4S (460V) TXV 57500 15.5 11.7 CX35-60C SL280UH110V60C 10248286SSB060H4S (460V) TXV 57500 15 11.7 CX35-60C SL280UH110XV60C 10248287SSB060H4S (460V) TXV 57000 15 11.7 CX35-60C SLO185B124/141V60 10248288SSB060H4S (460V) TXV 57500 15.5 11.7 CX35-60C SLP98UH090XV60C 10248289SSB060H4S (460V) TXV 57000 15.5 11.7 CX35-60C SLP98UH110XV60C 10248290SSB060H4S (460V) TXV 57500 14.5 11.7 CX35-60C 10248291SSB060H4S (460V) TXV 57000 15.5 12 CX35-60D EL180UH135E60D 10248292SSB060H4S (460V) TXV 57000 15 11.7 CX35-60D EL195UH135XE60D 10248293SSB060H4S (460V) TXV 57000 15 11.7 CX35-60D EL296UH135XE60D 10248294SSB060H4S (460V) TXV 57000 15.5 11.7 CX35-60D EL296UH135XV60D 10248295SSB060H4S (460V) TXV 57000 15.5 12 CX35-60D SL280UH135V60D 10250489SSB060H4S (460V) TXV 57000 15 11.7 CX35-60D SLO185BF124/141V60 10248296SSB060H4S (460V) TXV 56000 15 11.7 CX35-60D SLO185UF124/141V60 10248297SSB060H4S (460V) TXV 57000 15.5 12 CX35-60D SLP98UH135XV60D 10248298SSB060H4S (460V) TXV 56500 14 11 CX35-60D 10248299SSB060H4S (460V) TXV 57500 16 12 CX38-62C SL280UH090V60C 10556156NOTES: TXV = Matched with Thermostatic Expansion Valve.Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.

Page 53: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model
Page 54: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model
Page 55: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model
Page 56: SSB 3-5 TON AIR CONDITIONERS AIR … CONDITIONERS SSB S-CLASS® SPLIT SYSTEM ... Three phase power supply. ... See Specifications table for selection. Not available for -060 model

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.

REVISIONS

Visit us at www.lennox.com

For the latest technical information, www.lennoxcommercial.com

Contact us at 1-800-4-LENNOX

REVISIONS

Sections Description of Change

AHRI System Matches Updated