Page 1: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003
Page 2: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

1 1 Vol 1Clause 7.7.2 of

PC-E-1003

Specifies sample welds quantity under (i), (ii), (iii), page 11 of

22.Clause 5.1 (iv), page no 4 of 16 of PC-M-1002 also

specifies quantities to be procured for weld qualification.

We understand quantities mentioned under PC-M-1002 will

sufficent requirement mentioned in PC-E-1003 for welding &

qualification at our end.

These are not deliverable.

specification is self explanatory. Spec PC-M-1002 is for

forging. While spec PC-E-1003 is for Header

manufacture.

2 2 Vol 1Clause 7.7.5 of

PC-E-1003

States for stress relieving.

We require Heat treatment procedure and stress relieving

cycle.

Soaking temperature shall be 600 +10/-5 °C ; Rate of

heating/cooling 50 degree C

3 3 Vol 2

Clause 5.1 (v)

page no 4 of 16 of PC-M-1002

We understand these samples are required at forger end to

qualify process.

These are not deliverable.

These samples are deliverables

4 4 Drawing Drawing 2005/DD - Sections Nozzle 80NB

Nozzle 80NB pipe is not covered in BOM of drawing

2006/DD,

We understand 80NB pipe is not required, please advise.

80 NB pipe is not required

5 5We understand that, there are NO Spares and Erection &

Commissioning under contractor scope. Please confirm.YES. It confirmed.

6 6

Do we need to carry out any Mock-ups for Technical

Qualification? If yes, we want to understand the mock-ups

required

As per tender condition.

7 7 Please Share the NPCIL approved source for header forging.

Suggested vender for header forgings based on the

previous supplies is M/s FAV Italy. However, bidder

may also refer Clause no 1.6 of Section-C1 of Tender

documents in this regard.

8 8Please Share the NPCIL approved source for seamless pipe SA

333 Gr6.

Suggested vender for seamless pipes based on the

previous supplies is M/s ISMT Ahmednagar. However,

bidder may also refer Clause no 1.6 of Section-C1 of

Tender documents in this regard.

9 9Please Share the NPCIL approved source for fittings, elbows,

welding inserts.

Suggested vender for fittings based on the previous

supplies is M/s Tectubi Italy. However, bidder may also

refer Clause no 1.6 of Section-C1 of Tender documents

in this regard.

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

Name Of Bidder : Godrej & Boyce Mfg Co Ltd

Other Queries

Page 1 of 11

Page 3: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

10 1 Volume-II Material Specifications:PC-E-1002, PC-E-287 &

PC-E-288

Please provided approved source of Suppliers for Reactor

Header Forgings and also arrange the Forging Drawings.

NPCIL do not have any list of suppliers. However for

the current order of KAPP-3,4 and RAPP-7,8 header

forgings were supplied by M/s FAV Italy, Feeder stub

by M/s ISMT Ahmednagar, Fittings by tec tubi Italy.

11 2 Volume-I Section-B, Clause No. 9.5 Custom ClearanceIf raw material is Imported, the necessary customs duty

exemption certificate shall be provided by NPCIL.

Kindly refer clause no 9.0 and 15 of ITT , which is self

explanatory

12 3 Volume-I

Section-A,Clause No. 10 & Section-B, 10.3 Test

Charges, Spares and Accessories & Supervision of

Erection & Commissioning Charges

We understand that there is no Spares and Erection &

Commissioning under contractor scope. Please Confirm.YES. It confirmed.

13 4 Volume-II

Technical Specification for Seamless Carbon Steel

Pipes and Butt Welding Seamless Fittings For

Feeders, PC-M-287 (page no. 7 of 18) and drawing

no. GHAVP-1&2/33117/2004DD (zone F3 & F4

Please provid Pipe schedule for 100 NB, 80NB, 65NB, 50NB

& 20NB

These Pipes are ID controlled non standard pipe. ID

and thickness are given in specification PC-M-287

14 4 Volume-II

Technical Specification for Seamless Carbon Steel

Pipes and Butt Welding Seamless Fittings For

Feeders, PC-M-287 (page no. 7 of 18) and drawing

no. GHAVP-1&2/33117/2004DD (zone F3 & F4)

& Drg no. GHAVP-1&2/33117/2006/DD (BOM)

we understand that 80NB Pipe is not in our scope. Please

Confirm 80 NB pipe is not required

15 5 Volume-IISub-Section C-1, Special Instruction to the Tender,

Clause no. 1.6 (Page no 6 of 14)

Prototype forgings which shall be certified by NPCIL - Which

can be Prototype forgings of sample length piece or one of the

full header. Please Confirm

As per tender condition.

16 6 Volume-IISection - B, Clause no. 9.2 Free issue material

(Page no. 39-of 54)

Please clarify whether any FIM Shall be provided by NPCIL

or not. If yes please send the details of FIM.No FIM to be issued.

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

17 1 FTT-1133 sec A ITT/first5.3a/Technical specification,technical detail &

litrature

Please be more specific about what technical

specification,technical detail & literature required with part-I

of E-bid

18 2 FTT-1133 sec A ITT/first 5.3c/Drawing with part-I E-bid

As per our understanding drawing issued with the enquiry

shall be signed and stamped that shall be submitted along with

part-I of E-bid

19 3 FTT-1133 sec A ITT/first 10.1.2/Test charges Kindly inform what routine test ,special type test required Tender /Specification is self explanatory.

20 4 FTT-1133 sec A ITT/first 10.2.1/spares and accessoriesKindly inform what all items are required as a spares

necessory for safty operationNo spares item required.

Name Of Bidder : M/s. MTAR Technologies Pvt. Ltd., Hyderabad.

Name Of Bidder : M/s. Jindal steel and power ltd. ,machinery division ,Raipur

Tender /Specification is self explanatory.

Page 2 of 11

Page 4: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

21 5 FTT-1133 sec A ITT/first 17/Consortium

Is consortium is applicable for this tender or not because as per

clause GCC/supply-I/R4 clause 1.11 consortium can be made

priors to purchaser approval

Tender condition shall prevail.

22 6FTT-1133 sec A

ITT(Appendix X)/first

2.d/Qualfication required for bidder(Technical-

Furnace)

Currently we don,t posses gas fired/electric furnace of 15

Metres length in our plant so we shall be allowed to sub-

contract to perform PWHT for these equipments to your

approved reputed vendor. Is it allowed to carry out PWHT on

Modular furnace for which calibration will be done prior to

PWHT of the headers?

PWHT shall be done in-house for the complete header

assembly in a single charge in a calibrated furnace.

23 7 GCC/supply-I /R4-First vol. 4.1/Scope of work

please specify wheather mechnical design is in bidder scope or

not .Currently we are considering we shall be furnishing

manufacturing drawings based on design detail provided by

the purchaser.

Mechanical design is not in bidder scope.

24 8 33117/PC-M-1002-2nd vol. 9.3/Fatigue test

a) Please clarify that fatigue test to performed on each header

or one number per heat of all the headers or just One

Number per order(for header only)

B) Is fatigue test is to be performed on pipe and fittings as

well?

a) Kindly refer 9.3 which is self explanatory.

(b) No fatigue test required for pipe fitiing.

25 9 33117/PC-E-1003-2nd vol. 7.7.5/Heat treatment

Please elaborate on how to perform purging with inert gas

during heat treatment to avoid oxidation on inner surface f the

headers?

Purging is required during PWHT.

26 GENERAL QUERIES

27 10

Kindly provide approved Vendor list for Materials,Heat

Treatment service Provider/ Calibration agency, Helium Leak

Testing agency, Machining facility if not done by forging

manufacturer.

Currently we have no approved vendor list.

28 11 Wheather we have to perform recordable UT or not As per tender condition.

29 12 Which ASME edition we have to consider 2015 or 2017ASME 2015 or Latest eddition as on NIT issuued date

shall be used.

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

30 1

Volume-IV Specification

No. PP-E-1210 for MPE of

Ferromagnetic Material

PP-E-1210 for MPE of Ferromagnetic Material is

R-1. Whereas, there is no mention for the Revision

of document for the Specification No. PP-E-1210

attached with the tender.

Kindly clarify and send correct specification. R-0 is correct

Name Of Bidder : M/s. Walchandnagar Industries Limited.

Page 3 of 11

Page 5: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

31 2Clause 8.2, Specification

PC-M-1002 R0

Material procurement spec calls for simulated heat

treatment for coupons subjected to soaking

temperature of 600+/-10 ⁰C (i.e 590 to 610).

However, code ASME sect III sub section NB-4600

specifies soaking temperature of 595 ⁰C min.

The simulated heat treatment for forging coupons shall be with

soaking temperature of 600+10/-5 ⁰C (i.e 595 to 610). This

temperature range will meet code ASME sect III sub section

NB-4600 having soaking temp 595 ⁰C min.

The above will match technical specification no. PC-E-1003

R1, Clause no. 7.7.5, the equipment heat treatment shall be as

per NB-4600 of ASME sec III, Table NB 4622.1-1.

Soaking temperature shall be 600 +10/-5 °C

32 3

Specification PC-M-287

R1, PC-M-287 R0 and PC-

M-1002 R0

Carbon steel seamless pipe, pipe fittings and piping

components. Reactor Header Carbon steel forgings

Kindly inform names of probable suppliers for Carbon steel

Forgings, seamless pipe, pipe fittings and piping components.

Suggested venders for header forgings based on the

previous supplies are M/s FAV Italy, Feeder stub by M/s

ISMT Ahmednagar, Fittings by M/s Tec Tubi Italy.

However, bidder may also refer Clause no 1.6 of Section-

C1 of Tender documents in this regard.

33 4Clause 4.1, Specification

PC-M-1003

Applicable specificaion & Code -

Applicable ASME specification Edition is not

specified

ASME Section -II, III & V Code we will follow 2017 Edition

which is latest. NPCIL to confirm the same.

ASME 2015 or Latest eddition as on NIT issuued date

shall be used.

34 5

Drg No. GHAVP-1&2/

33117/2001/DD

Note 5 & 10

Not specified tolrances, bidder to indicate best

tolerance achievable.

General Tolerance is indicated +/-3mm where ever

the tolerance value is not given.

a) For 100 NB feeder pipe positional tolerance we propose +/-

5 mm in place of +/-3 mm to accommodate cold correction

after bending of higher thk and OD pipes.

b) The stub height tolerance shall be kept +/- 5mm in place of

+/-3 mm.

Tender specification and drawings shall prevail.

35 6Clause 9.3, Specification

PC-M-1002 R0

Tecchnical specification for Reactor header Carbon

steel forgings - Fitigue Test

NPCIL to confirm standard for conducting the Fitigue test

since it not mentioned.

Fatigue tests shall be carried out in accordance with

ASTM E606 and ASME Section III.

36 7APPENDIX-X, Qualifying

requirements

Clause No. 2.0 Technical, 1.0, d. Availability of

Suitable calibrated furnace (Gas fired / electric) to

carry out uninterrupted Posr weld heat treatment.

AA) We propse to carry out Post weld heat treatment of

Header assembly in 2 stages in the existing furnace as follows -

1) Heat treatment of 2/3 length of assembly in furnace and 2)

Reverse it & heat treat 2/3 portion of assembly (with overlap)

in furnace.

OR

BB) Install a new furnace to suit entire Header assemby for

heat treatment in a single charge well before the header

assemblies become ready for heat treatment.

PWHT shall be done in-house for the complete Header

assmebly in a single charge in a calibrated furnace.

Terms of payment

Quantum of material procurement is about 60 to 70% of value

of Purchase Order of Header assemblies and hence Terms of

payment need to be modified as follows :

a)  10% of PO value against placement of PO for

Header Forgings a)     10% of PO value against unconditional acceptance of PO

b)  5% of PO value against placement of PO for

Feeder Stub Pipes.

b)     15% of PO value against placement of PO for Header

Forgings

c)  10% of PO value against receipt of Header

Forgings

c)     05% of PO value against placement of PO for Feeder

Stub Pipes.

d)  5% of PO value against receipt of Feeder Stub

Pipes d)     25% of PO value against receipt of Header Forgings GCC Clause No. 5.6 and

SCC 3.0Will be responded later37 8

Page 4 of 11

Page 6: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

e)  20% of PO value against dispatch of each pair

of Header Assemblies on prorate.e)     05% of PO value against receipt of Feeder Stub Pipes

f)    35% of PO value, 100% statutory levies,

transportation charges, price adjustment amount on

receipt of each pair of Header Assemblies at site on

prorata.

f)      30% of PO value, 100% statutory levies, transportation

charges, price adjustment amount on receipt of each pair of

Header Assemblies at site on prorata.

g)  05% of PO Value on receipt of final

documentation for each pair of headers

g)     10% of PO value against receipt of documentation and

acceptance of pair of Header Assemblies at site on prorata.

h)  10% of PO value against acceptance of all

Header Assemblies, 16 Nos. at site

38 9 SCC clause No. 8.0

1.1.8 Taxes & Duties : GST as applicable or

quoted, whichever is lower will be reimbursed by

Purchaser limiting to the rate prevailing within the

contractual delivery schedule

Billing address if considered as NPCIL, Mumbai Then, GST

applicable will be 9% SGST & 9% CGST as per HSN Code

84014000. If billing address is considered as GHAVP-1&2

site then GST applicable will be 18 % IGST.

NPCIL to confirm the following -

1) Billing address

2) GST HSN Code No.

3) GST tax structure

4) GST tax strcure with HSN Code for cost of transporataion

5) NPCIL to specify GST % that will be applicable on LD

amount, if any, and to give proof of GST paid on LD amount

1) Billing address to be considered is GHAVP-1&2

quoting their GSTN No. 06AAACN3154F1ZU.

Original bill to be dispatched to NPCIL Mumbai for

payment purposes.

2) GST HSN code No. as applicable for the tendered

items should be indicated by the bidder in the Annexure

B (refer SL No. 3.3 (a) and 3.3 (b) of Annexure B.

3) GST tax structure applicable as per the GST act and

to be indicated in the Annexure B sl No. 3.2 (a) to (d).

4) In the case of FOR contracts, the transportation

would form part of the main supply and will be treated

as composite supply and hence, the GST as applicable

as per the GST act for the main supply has to be

considered for the whole contract.

5) GST applicable on LD amount will be 18%. The

discharge of GST liability on outward taxable supplies

will be consolidated on monthly basis, and proof canot

be provided separately for any particular payment. GST

invoice for GST charged on LD (if any) will be

provided by NPCIL.

39 10

Clause no. 7 for "Scope of supply" and Clause No.

8 for "Tax liability on composite supply" of THE

CENTRAL GOODS AND SERVICES TAX ACT,

2017, NO. 12 OF 2017 (Copy attached) says the

following

Cost of equipment shall covered under Goods and cost of

transportation will be covered under Services. It will a

composite supply. In such a case the item of goods or

Transportation whichever calls higher GST rate will be

applicable for both items considering it as composite supply.

In all, all the items of supply and transportation cost will

attract GST as that of supply of goods.

In the case of FOR contracts, the transportation would

form part of the main supply and will be treated as

composite supply and hence, the GST as applicable as

per the GST act for the main supply has to be

considered for the whole contract.

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

Name Of Bidder : M/s. Larsen & Toubro Limited, Heavy Engineering IC,

GCC Clause No. 5.6 and

SCC 3.0Will be responded later37 8

Page 5 of 11

Page 7: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

40 SCC No.3

We wish to propose the following terms of payment:

a) 10% Advance against acceptance of purchase order

b) 10% on submission & approval of drawings & documents

c) 10% on placement of Purchase Order for Reactor Header

Forgings

d) 05% on placement of Purchase Order for Feeder stub pipes

e) 10% on receipt of Forgings for each Reactor Header

Assembly on pro-rata basis

f) 05% on receipt of Feeder stub pipes for each Reactor

Header Assembly on pro-rata basis

g) 10% on issuance of Shipping Release for each Reactor

Header Assembly on pro-rata basis

h) 30% along with 100% of price adjustment, if any, 100% of

GST on price adjustment, on receipt of each Reactor Header

Assembly at site on pro-rata basis

i) Balance 10% on pro rata basis against final acceptance of

Reactor Header Assemblies at

site and receipt of Final Documentation at site

All the advances and progressive payments for Sr. No. (a) to

(f) above will be against submission

of Advance Bank Guarantee of equivalent amount valid till

Contractual Delivery Date.

We wish to assure you that the above payment schedule will

not only help us ensure priority resource allocation to the job

but also will help us offer best price for the supplies to NPCIL.

Will be responded later.

41 SCC No.8 Taxes & Duties

GST will be applicable on Price Adjustment amount. Kindly

confirm that the same will be reimbursed by NPCIL to the

Supplier at actuals.

Please refer to SCC Clause No. 11.0 (GCC Clause ref

No. 5.4). Price adjustment will be allowed upto a ceiling

of +/- 20% of the total FOR price (inclusive of taxes and

duties) component. Since, the Price adjustment is

alloswed on the taxes and duties component also, no

separate GST on price adjustment will be reimbursed by

NPCIL to the supplier.

42 SCC No.8 Taxes & DutiesKindly confirm that the GST invoice for GST charged on LD

(if any) will be provided by NPCIL

GST Invoice for GST charged on LD (if any) will be

provided by NPCIL.

43 SCC No.8 Taxes & DutiesKindly confirm that no GST TDS will be applicable, as we are

not dealing with Govt. directly.

No GST TDS is appplicable currently. The same will be

deducted by NPCIL, if notified by Government in this

regard, during the currency of the Contract.

Page 6 of 11

Page 8: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

Sr. No.BiddersQ

uery No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

44 1 Technical Specification

1. As per the master index, list of specifications are mentioned

as PC-E-1002 , PC-E-287 & PC-E-288. Attached

specifications are PC-M-1002, PC-M-287 & PC-M-288.

Please Clarify.

Attached specifications are correct one

45 2II & Spec :PC-E-1003 Page

no 164Technical Spec. for Reactor Header assy Clause 6.2 Tender Specifications shall prevails

46 3II & Spec: PC-M-288 Page

no 214

Technical Spec. for Carbon steel seamless

Pipes,Pipe fittings and Piping Components for

Primary System. Clause 5.2 b) ii

47 4 II & Spec: PC-M-287Technical Specification for Carbon steel Pipes and

Butt Welding Seamless Fittings for Feeders.

48 5Spec. PC-M-1002 Page no

238

Technical Specification for Reactor Header Carbon

Steel Forgings Clause 10.6 Table Sl No:4

49 6Spec. PC-M-287 Page no

187

Technical Specification for Carbon steel Pipes and

Butt Welding Seamless Fittings for Feeders. Clause

4.1.3 (d).(4)

50 7Spec: PC-M-1002 Page no

236

Technical Specification for Reactor Header Carbon

steel Forgings. Clause 9.5

Tender Requirement : The specimen shall be cold bent

through 180° on a mandrel of 25.4 mm diameter. Clarifiation

Required : Please clarify whether mandrel of 25.4 mm dia is

to be used irrespective of thickness of specimen for Bend Test.

Other wise , mandrel dia shall be mentioned based on

thickness of Specimen (Like 4t Where “t” is the thickness of

Bend specimen)

Tender Specifications shall prevails

Tender Requirement : 1. Hardness Test (£197 HB) 2.

Hardness test: Fittings shall have maximum hardness of 197

HB. Clarifiation Required : Hardness Maximum Limit has

been given. ”Acceptable Range of variation in Hardness” is

also to be obtained.

The leak rate shall be calculated from the indicated

value using the formula mentioned in para-IX-1070 of

Article 10 of ASME section V"

Shall have maximum hardness of 197 HB.

Tender Requirement : 1. Impact test shall be done at a

temperature of RTNDT+33°C(not greater than +18°C) 2. The

pipes, fittings/ Components shall be impact tested …..The

impact Test Temperature (RTNDT+56°C) shall not be higher

than +18°C…. Calrification Required : 1) As per ASME

SEC-III NB-2332 (b) , Impact test at RTNDT+56°C is to be

done for Pressure retaining material(Piping, Pumps ,and

Valves Excluding Bolting Materials) with nominal wall

thickness greater than 64 mm. The components/welds which

are to be impact tested at RTNDT+56°C shall be clearly

mentioned. 2) Impact Test is not demanded as per

PC-M-287.The applicable components for PC-M-287 & PC-

M-288 shall be distinguished clearly .

Spec PP-E-2384 Rev.No. 0

Page no 309

NDE Procedure- Specification for Helium Leak

Testing in Vacuum Mode. Clause 9

Tender Requirement :…leak rate can be calculated from the

indicated value using the formula mentioned in para V-1062 of

Article 10 of ASME Section V. Clarifiation Required : Para V-

1062 of Article 10 is for System Calibration in “Tracer Probe

Technique” and not for leak rate calculation. But Testing

procedure mentioned in para 8.4 of PP-E-2384 is as per “Hood

technique”. Please Clarify.

8

All mandatory tests as required by respective ASME

material specifications are to be carried out. In addition,

any requirements specified in NPCIL specifications are

also to be met.

Name Of Bidder : M/s. BHARAT HEAVY ELECTRICALS LIMITED

51

Page 7 of 11

Page 9: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

52 9Spec : PC-M-1002 Page no

236

Technical Specification for Reactor Header Carbon

Steel Forgings Clause 9.3Standard for conducting Fatigue test is to be mentioned.

Fatigue tests shall be carried out in accordance with

ASTM E606 and ASME Section III.

53 10Section-B General

Condition Page no 87General Condition –QA Manual Clause 10.1.2

Tender Requirement : ….,prepare a QA manual , which shall

be finally accepted by the purchaser…… Clarifiation

Required: No customer approval is envisaged for company

Manual / Ref. documents /standards. However extract of

quality programme shall be given.

QA Manual shall be submitted to NPCIL QA for review

and the supplier's QA system shall be audited by NPCIL

periodically for its compliance, if required.

54 12

Technical Specification for

Reactor Header Assembly /

PC-E-1003 Page no 8 of 22

Piping loads for analysis Clause 7.3/ Fabrication

Tender Requirement/Issue : Piping loads are not provided

Clarifiation Required : As per tender, the Supplier need not

carry out the analysis as long as meeting the tender drawing

requirements. However, NPCIL may be asked to provide all

piping loads for Analysis and the same will be used for

clearing any manufacturing deviations where we are required

to provide design justification as the basis of acceptance.

Any manufacturing deviation shall be reviewed by

NPCIL for acceptance / rejection.

55 13Technical Specification /

PC-E-1003 Page no 3 of 22

Applicable ASME Specification Clause 4.1 /

Applicable Specification and Codes / Standards

Tender Requirement/Issue :Edition is not specified

Clarifiation Required : For ASME Section-II, III & V Code

we will follow 2017 Edition which is the latest. NPCIL may

confirm same.

ASME 2015 or Latest eddition as on NIT issued date

shall be used.

56 14

Technical Specification /

PC-E-1003 and Drg. No.

GHVAP-

1&2/33117/2007/DD Page

no

Manufacturing of Tee and Elbow Assembly Clause

20 NB Fittings

In order to simplify the manufacturing activities of

instrumentation connection, we propose Welded Bifurcate

where a single pipe is formed in the form of ‘U’ and at the

centre of the ‘U’, the nozzle pipe is welded instead of forming

the connection with Tees, Elbows and Pipes. This will ease the

fabrication.

Tender condition shall prevail.

57 15

Drg No. GHAVP-

1&2/33117/2004/DD &

GHAVP-

1&2/33117/2005/DD

ID and OD of 20 NB Clause GHAVP-

1&2/33117/2004/DD (Detail-T) & GHAVP-

1&2/33117/2005/DD (Sections- ROH and RIH

Nozzle 20 NB)

Tender Requirement/Issue :Two different values are shown in

different drawings Clarifiation Required : IN RIH & ROH,

for 20NB Nozzles, the dimension of OD is 26.7(+2/-0) mm

and ID is 15.6±0.2 mm (Ref. GHAVP-1&2/33117/2005/DD)

whereas in Dwg: GHAVP-1&2/33117/2004/DD (Detail-T),

the dimensions of 20 NB pipe are shown as ID 18.8 mm and

OD 28.8 mm. Kindly confirm the ID and OD dimensions.

For pressure measurement connection,20NB schedule

160 ( OD = 26.7 mm,WT = 5.56 mm ) pipe and fittings

shall be used.

58 16Technical Specification /PC-

M-288 Page no 10 of 17

Impact test temperature of pipes, fittings/

components Clause 5.2/ Material Inspection and

Tests

Tender Requirement/Issue Two different values are given in

the documents mentioned Clarifiation Required : In clause

5.2, the impact test temperature is specified as RTNDT+56°C.

As per ASME Section III NB-2331 , which is applicable for

vessels & tender document PC-E-1003 (Clause 6.2, Page 6 of

22), the impact test temperature is TNDT+33°C. Kindly

clarify.

Tender specification shall prevails.

59 17

PC-E-1003 & PC-M-287

Page no PC-E-1003 (5 of

22 and 17 of 22) PC-M-287

(6 of 18)

Hydrostatic testing of Butt welding pipe fittings

Clause PC-E-1003 (Clause-5 & 8.11) and PC-M-

287 (Clause-4.1.3)

As per clause(5) & clause(8.11) of PC-E-1003, the hydro test

pressure of the assembly is 158 kg/cm2. In PC-M-287,

clause(4.1.3), in the table, the hydrostatic test pressure for the

samples of fittings is mentioned as 174 kg/cm2. Kindly clarify

the hydrostatic test pressure value.

kindly refer tender document which is self explanatory.

Page 8 of 11

Page 10: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

60 18PC-M-287 Page no PC-M-

287 (7 of 18)

Bore and wall thickness details of 20 NB elbow

Clause PC-M-287 (Clause-4.1.3/(e))

In the technical specification PC-M-287, which shall be used

as a base document for purchase of butt welding seamless

fittings, the dimensional details of 20 NB elbow is not

specified in clause no. 4.1.3/ (e). Kindly clarify.

20 NB pipe/fittings are standard component. Please

Refer drawings for details.

61 19 Vol II / C Page no 4 of 14Special instruction to the tenderer. Procurement of

RM Clause 1.6

Tender Requirement/Issue :Bidders may please note that

materials like header forgings, end caps etc. shall be procured

only from those vendors who have earlier supplied these items

for similar applications (i.e. Reactor Headers of Nuclear

Power Plants) as per requirement of ASME Section-III NB

and meeting the requirement of Purchaser’s specifications.

This is to be established by a documentary evidence.

Clarifiation Required : Documentary Evidence may be

clarified in detail.

Documentary evidence like P.O, Manufacturing

Processor ,QAP, Shipping release etc.

62 20 Vol II / C Page no 19 of 20 PC-M-1002. Quality surveillance Clause 14

Tender Requirement/Issue : The header forgings shall be

subjected to quality surveillance by the purchaser or his

authorised inspection agency. Clarifiation Required : Sample

QAP is requested. May pl. provide details regarding the

inspection agency.

Suggested QAP is attached with the tender document.

Details of inspection agency will be communicated to

the successful bidder.

63 21 General

Instead of HT of full header, it is proposed for local HT for

Dished end. Since thickness of feeder pipe is less than 19mm,

HT is not warranted as per section III NB, Table 4622.7(b).

Not acceptable.

64 22 GeneralIn case of repair after HT, it is proposed not to raise NCR, as it

is a weld deposit over weld.Tender condition shall prevail.

65 23 General

Whether the mentioned thichness of weld on weld joint for

outlet headers is bend side min. thickness or parent material

min. thickness after welding /repair, needs to be clarified.

Tender condition shall prevail.

66 24 General

The thickness in the bend region(after thining) of the feeder

pipes to be taken care such away that slight increase in

thickness of the pipe.which is very marginal leads to

NCR/DCR in all headers

Tender condition shall prevail.

67 25 General 20 NB thickness in bend region to be taken care Tender condition shall prevail.

68 26 General

NDE is 100% customer/third party witness is given in the

tender for all MPI,RT,UT,PT may be reduced in percentage

level.

Tender condition shall prevail.

69 27 General

Consider the feeder pipe thickness to avoid thickness built

up in weld joint after merging will reduce cycle time and

rework.

Tender condition shall prevail.

70 1Contractor shall submit…… out in the previous

month

Photographs of the job cannot be provided due to security

reasons..Tender condition shall prevail.

71 2The manufacturer shall ….. will be borne by the

manufacturer.

QS officials to be deputed within a day of inspection call. The

cost of retesting and re-inspection will be borne by the

purchaser if the item is delivered without any default of the

contractor.

Not accepted.

Page 9 of 11

Page 11: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

72 3 No advance is envisaged as per terms of payment

BHEL requested payment terms are as mentioned :

10 % Advance.

10 % on PO placement of RH Forgings.

5% on PO placement of Feeder Stud pipes

10 % on receipt of RH forgings at Contractor's works.

5% on receipt of Feeder stub pipes at Contractor's works.

20% on dispatch of each pair of reactor header assembly on

pro-rata basis.

25% upon safe transport & receipt of each pair of Reactor

Header Assembly, along with 100% of safe delivery charges.

5 % on pro-rata upon recipt of Final Documentation of each

pair of RH.

10% on Final Acceptance of all materials.

Will be responded later

Sr. No.

Bidders

Query

No.

Tender Section/Vollume

NameClause No./Subject Description Of Query NPCIL's Response

73 1 General -We have not received NPCIL AVL , please provide vendor

list for Forgings , fittings and weld consumables.

NPCIL do not have any list of suppliers. However for

the current order of KAPP-3,4 and RAPP-7,8 header

forgings were supplied by M/s FAV Italy, Feeder stub

by M/s ISMT Ahmednagar, Fittings by tec tubi Italy.

74 2

Technical specification

for Reactor assembly PC-

E-1003

7.71125 Deg C tempraure shall be maintained only for those

joints , which are required to be maintained as per code.As per tender condition.

75 3

Technical specification

for Reactor assembly PC-

E-1003

7.71 Please confirm acceptable welding processes.

welding shall be done by Electric arc welding process,

(GTAW,SMAW , SAW), and other process as specified

in tender specification.

76 4 Drrawings Tolerances We understand that where tolerance is not given, ± 3mm

shall be acceptable e.g (Centre to centre distance of pipes)Tender specification / drawing prevails.

77 5 PP-E-2356 Rev 01 8.2.2Please allow us to use X-ray in place of radium for less

than 19mm butt joints.Acceptable.

78 6 Drrawings Header thicknessPlease confirm margin to be considered in header wall

thickness.Tender specification / drawing prevails.

79 7 Genearl -

For components for whom material specification is not

given (e.g caps for hydro ), same shall be procured as

per code only , no special requirement is considered.

Yes, acceptable.

80 8 Genearl Scope of TPI Please confirm TPI and its scope. As per tender condition.(No TPI is allowed)

81 9 NDT Scope of UTPlease confirm scope of UT ,i.e. for which joints UT shall

be applicable?As per tender condition.

NAME OF BIDDER : M/s. Isgec Heavy Engineering Ltd

Page 10 of 11

Page 12: Sr. No. - e Tenders. No. BiddersQ uery No. Tender Section/Vollume Name Clause No./Subject Description Of Query NPCIL's Response 1 1 Vol 1 Clause 7.7.2 of PC-E-1003

Response of NPCIL to Pre-Bid Queries for TENDER NO. CMM/FTP/10-31-1-1133 (Tender ID-28556)

82

Feeder pipe thickness mention in specification PCM-287-Rev1

page 5 of 18 Para 4.1.2.f and in drawing no. GHAVP-

1&2/33117/2006/DD Rev.0 are contradictory. Please confirm

which thickness has to be followed.

Tender specification /drawing shall prevail.

83

Refer point 3.0 of SPC, Payment Termsۥ, we request for

milestone payments as mentioned below:

a) 1st Milestone on placement of Purchase Order for

Reactor Header Forgings as 15% in place of 10%

b) 2nd Milestone on placement of Purchase Order for

Feeder stub pipes as €œ10%€• in place of 5%

c) 3rd Milestone on receipt of Reactor Header Forgings at

Contractor’s works as “15%€• in place of €œ10%

d) 4th Milestone on receipt of Feeder stub pipes at

Contractor’s works as “10% in place of €œ5%

e) 5th Payment against dispatch of each pair of reactor

header assembly as 20% - No change.

f) 6th Payment upon safe transportation & receipt of

Reactor Header Assembly as €œ20% in place of €œ35%

g) 7th Payment upon receipt of Final Documentation as

5% - No change.

h) 8th Payment against final acceptance of all the materials

at Site as 5% in place of €œ10%.

All balance conditions for payment terms as per SPC point no.

3.0.

3) Refer point 3.0 of SPC, “Payment Terms, all payments

shall be released within 21 days of submission of invoice along

with supporting documents.

Will be responded later

84

Bid Validity as per Tender: Validity date (120 days from the

opening of Part-II Price Bid ) for the bid has been accepted.

ISGEC Clarification: This clause requires acceptance to

unlimited bid validity as the date of opening of Price bid is not

fixed / known. In view of the same, we can offer bid validity

of 120 days from date of tender submission.

Tender Conditions shall prevail.