6/16/17 SR-9-17, 400H 1
AA# 3619 Case File: SR-9-17, 400H
Administrative Action Administrative Site Review
Case File / Name: SR-9-17, 400H General Location: This site is located on the southwest corner of the intersection of West Edenton
Street and North Harington Street and is within the city limits. CAC: North Central Request: Development of a 1.01 acre tract zoned DX-20-SH into a 20 story, 244 ft. tall
mixed use (residential, retail, and office) building.
Cross- Reference: TR# 501332
SR-0-17, Location Map
City of Raleigh Development Plans Review Center
One Exchange Plaza Raleigh, NC 27602
(919) 996-2626 www.raleighnc.gov
6/16/17 SR-9-17, 400H 2
AA# 3619 Case File: SR-9-17, 400H
SR-9-17, Preliminary Site Plan
6/16/17 SR-9-17, 400H 3
AA# 3619 Case File: SR-9-17, 400H
Public Works Design Adjustment
6/16/17 SR-9-17, 400H 4
AA# 3619 Case File: SR-9-17, 400H
6/16/17 SR-9-17, 400H 5
AA# 3619 Case File: SR-9-17, 400H
6/16/17 SR-9-17, 400H 6
AA# 3619 Case File: SR-9-17, 400H
Code Conformance:
Code Section(s)
Zoning District: DX-20-SH 3.1
Overlay District: NA 5.1
Parking: Required Parking (207 residential units x 1 space/unit) – (16 residential units x 1 space/unit) = 191 spaces (143,351 s.f. office x 1 space/500 s.f.) = 287 spaces (16,926 s.f. retail x 0 (DX exemption)) = 0 spaces Total required spaces = 478 spaces Proposed = 298 (on site) + 670 (Remote parking - Power House Parking Deck which consists of 294 existing spaces and 376 proposed spaces) = 968 Total proposed = 968 spaces (on site in deck, and remote in deck) Off- site parking is proposed in the nearby Power House Parking Deck with renovations to be done under separate permit Required Bicycle Parking Short Term = 15 (office) + 4 (retail) + 11 (residential) = 30 short term spaces. Long Term = 30 (office) = 30 long term spaces
7.1.2
Street Type(s): Hillsborough St is classified as an Avenue 3-Lane Parallel street, which requires 62' b-b with center turn lane on 90' r/w. West St is classified as a Main Street, Parallel Parking which requires 41' b-b on73' of r/w. 1/2 of 73' r/w required to be dedicated. N Harrington St is classified as a Main Street, Parallel Parking which requires 41' b-b on73' of r/w. 1/2 of 73' r/w required to be dedicated. W Edenton St is classified as an Avenue 4-Lane Divided street (UDO 8.4.6.A), which requires 1/2 the 122' r/w, b-b pavement, and street section.
8.4
6/16/17 SR-9-17, 400H 7
AA# 3619 Case File: SR-9-17, 400H
The existing 62' r/w is sufficient. Public Works Design Adjustment – As the development is within the City of Raleigh Christmas Plan, the right of way and property boundaries are to be allowed to remain as existing.
Streetscape: Main Street 8.5
Setbacks/Frontage: Primary Street = 3’ Side streets = 3’
3.4, 3.2, 2.2
Neighborhood Transitions:
NA 3.5
Transitional Protective Yards:
NA 7.2.4
Stormwater: Site is subject to Stormwater Control Regulations under Article 9.2 of the UDO. The site is claiming an exemption to runoff control requirements under 9.2.2.E.2.b as proposed development of the site will result in a less than 10% increase in runoff for the 2 yr, 10 yr, and 25 yr storm events. Site will address water quality with an underground sand filter. No buffers or floodplain exist on the site.
9.2
Tree Conservation: This site is less than two acres in size and therefore exempt from Article 9.1, Tree Conservation.
9.1
Variances, Design Adjustments,
Administrative Alternates:
Public Works Design Adjustment – As the development is within the City of Raleigh Christmas Plan, the right of way and property boundaries are to be allowed to remain as existing. Admin. Alternate (AAD- 9-17) – approval of an alternative design regarding the building massing requirements along three of the four streets. Admin. Alternate (AAD-9-17) – Approval of an alternate design regarding the 0/15’ “Build To” requirement along West Street.
Other: It is anticipated that the off- site parking agreement or easement will be with the nearby Powerhouse Square Parking Deck. Proposed renovations to this parking deck will be permitted under separate permit. A Certificate of Occupancy for the Powerhouse Parking Deck project is required prior to the issuance of a certificate of occupancy for this project (SR-9-17).
6/16/17 SR-9-17, 400H 8
AA# 3619 Case File: SR-9-17, 400H
OFFICIAL ACTION: Approval with conditions CONDITIONS OF APPROVAL: Prior to issuance of a mass land disturbing permit for the site:
1. That in accordance with Part 10A Section 9.4.4, a surety equal to of the cost of clearing, grubbing and reseeding a site, shall be paid to the City;
Prior to the issuance of any site permits, infrastructure construction plans or concurrent review process, whichever is applicable;
1. That a stormwater control plan including a soil boring and seasonal high water table report at the location of the proposed stormwater device, and a stormwater operations and maintenance manual and budget shall be approved by the Stormwater Engineer in compliance with Article 9.2 of the Unified Development Ordinance, prior to grading or the approval of construction drawings whichever event comes first;
2. That a nitrogen offset payment must be made to a qualifying mitigation bank;
Prior to issuance of building permits:
3. That the Private Drainage Easement as shown on the preliminary plan is recorded on plat.
4. That in accordance with Part 10A Section 9.2.2, a surety equal to 125% of the cost of construction of a stormwater device shall be paid to the City;
5. That approval by the North Carolina Department of Transportation is required prior to the installation of street trees along West Edenton Street;
6. That the developer shall pay to the City a stormwater facility replacement fund payment equal to twenty-four percent (24%) of the estimated cost of constructing all stormwater control facilities shown on the development plans;
7. That a tree impact permit is obtained from the City of Raleigh;
8. That in accordance with Part 10A Section 8.1.3, a surety equal to 125% of the cost of development related improvements, including streetscape trees on Hillsborough, West, North Harrington, and West Edenton Streets is paid to the Development Services Department;
9. That an encroachment agreement for any plantings, planters, awnings or stormwater drainage
systems that carry private drainage to be located within the public right-of-way is approved by the City Council by separate action. An application for encroachment into the public right of way for the landscaping located within the right of way as indicated on the preliminary plan, shall be submitted to the City’s Encroachment Coordinator in the Development Services Department for review, and that the City Council approve the encroachment request. Following City Council approval of the encroachment, an encroachment agreement, prepared in accordance with Raleigh City Code Sections 12-1001 and 12-1021(a), shall be filed with the Development Services Department, and the encroachment agreement is to be recorded with the Wake County Register of Deeds. Maintenance of the encroachment shall be the responsibility of the owner;
6/16/17 SR-9-17, 400H 10
AA# 3619 Case File: SR-9-17, 400H
4-Year Completion Date: Within four years after issuance of the first building permit for the site plan, the construction of the entire site plan must be completed unless an applicant has been granted vested rights. Failure to complete construction within this specified time frame shall automatically void the approved site plan for which no building permits have been issued.
WHAT NEXT?: • MEET ALL CONDITIONS OF APPROVAL.
• COMPLETE INFRASTRUCTURE CONSTRUCTION DRAWINGS FOR ANY PUBLIC IMPROVEMENTS Streets, Utility lines to be owned and maintained by the City.
• HAVE A REGISTERED SURVEYOR PREPARE FINAL PLATS FOR RECORDING. These also must be submitted to the City for authorization signature prior to recording with the Wake County Register of Deeds.
• MEET THE REQUIREMENTS OF THE EXPIRATION THRESHOLDS AS NOTED ABOVE.
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GT
ON
S
T
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
400 H
VICINITY MAP
SCALE: 1" = 400'
CIVIL ENGINEERING - LANDSCAPE ARCHITECTURE
APPLICANT/OWNER
ARCHITECTS
STEWART INC. - LANDSCAPE ARCHITECTURE
CONTACT: MARK SHAWL, PLA, LEED AP + BDC
LANDSCAPE ARCHITECT
919.866.4775 (T)
919.380.8752 (F)
BR HILLSBOROUGH PARTNERS LLC
104 LAKE CLIFF COURT
CARY, NC 27513
919-460-9786
CONTACT: GREGG SANDREUTER
919-460-9786(T)
STEWART INC. - CIVIL
CONTACT: JOE PUCKETT, PE, LEED AP
PROJECT MANAGER
919.866.4829 (T)
919.380.8752 (F)
NORTH
SITE
GENSLER
530 HILLSBOROUGH ST
919.239.7828
CONTACT: SCOTT LAGSTROM
919.239.7846(T)
919.239.7828(M)
400 HILLSBOROUGH STREET
RALEIGH, NC 27603
SUBMITTED ON JANUARY 20, 2017
REVISED ON FEBRUARY 24, 2017
REVISED ON APRIL 19, 2017
CITY OF RALEIGH
ADMINISTRATIVE SITE SUBMITTAL
TRANSACTION #501332 - SR-9-17
SITE DATA
PROJECT NAME: 400 H
SITE ADDRESS: 400 HILLSBOROUGH ST
COUNTY: WAKE
PARCEL PIN #:
1703591309, 1703591364, 1703591476,
1703592333, 1703592431 & 1703592436
PARCEL OWNER:
BR HILLSBOROUGH PARTNERS LLC & TIE
ONE LLC
PARCEL AREA: 1.01 ACRES
TOTAL DISTURBED/ PROJECT AREA:65,655 S.F. / 1.507 AC
CURRENT ZONING: DX-20-SH
EXISTING LAND USE: RETAIL
PROPOSED USE: MIXED USE RESIDENTAIL/RETIAL/OFFICE
RIVER BASIN: NEUSE RIVER
CONSTRUCTION TYPE: CONCRETE - STEEL
MAX BUILDING HEIGHT: 20 STORIES / 250'
PROPOSED BUILDING HEIGHT: 20 STORIES / 244'
EXISTING IMPERVIOUS AREA:52,394 S.F. / 1.20 AC
PROPOSED IMPERVIOUS AREA:55,166 S.F. / 1.27 AC
UTILITIES IMPROVEMENTS QTY
PUBLIC SEWER
8" SEWER 156 LF
PUBLIC WATER
6" HYDRANT LEG 10 LF
OVERALL PARKING SUMMARY
PARKING PROVIDED ON-SITE
POWERHOUSE
PARKING DECK
TOTAL
EXISTING SPACES TO REMAIN 0 294 294
NEW REGULAR SPACES 236 291 527
NEW COMPACT SPACES 52 69 121
NEW REGULAR ACCESSIBLE SPACES 7 12 19
NEW VAN ACCESSIBLE SPACES 3 4 7
TOTAL SPACES 298 670 968
(NEW & EXISTING)
TOTAL NEW PARKING 674
Br Hillsborough
Partners LLC
NOTES:
1. PROJECT IS UNDER TWO (2) ACRES, MAKING
IT EXEMPT FROM TCA REQUIREMENTS.
REFER TO CITY OF RALEIGH UDO SECTION
9.1.2, TREE CONSERVATION APPLICATION.
2. PROPERTY OWNER WILL USE PRIVATE TRASH
COLLECTION SERVICES FOR THE SUBJECT
PROPERTY.
3. THE PROPOSED PLANS CONFORM TO THE
CITY OF RALEIGH SOLID WASTE SERVICES
MANUAL.
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
C0.00
Sheet:
Z1.101 MIXED USE BUILDING PARKING PLANS
Z1.102 MIXED USE BUILDING PARKING PLANS
Z1.103 MIXED USE BUILDING PLANS
Z1.201 BUILDING ELEVATIONS
Z1.202 BUILDING ELEVATIONS
Z3.101 ZONING ADMIN ALTERNATE FINDINGS - STEPBACKS
BIKE PARKING SUMMARY
REQUIRED PROVIDED
SHORT
TERM
LONG
TERM
SHORT
TERM
LONG
TERM
OFFICE 15 30
RETAIL 4 0
RESIDENTIAL 11 0
TOTAL 30 30 30 30
VEHICULAR PARKING REQUIRED
S.F./UNITS DX REDUCTIONS ALLOCATED REQUIRED
RESIDENTIAL 207 UNITS
(16)
191 UNITS 211
OFFICE143,351 S.F.
0143,351 S.F.
287
RETAIL16,926 S.F. (30,000)
0 0
TOTAL PARKING REQUIRED 498
PARKING RATIO (MIN. REQUIREMENTS):
VEHICULAR SPACE - 1 PER 500 S.F. OF NON-RESIDENTIAL SPACE, 1 PER RESIDENTIAL UNIT NO MORE THAN 2 PER UNIT
BIKE SPACE (SHORT TERM) - 1 PER 20 RESIDENTIAL UNITS, BIKE SPACE (LONG TERM) - NONE
BIKE SPACE (SHORT TERM) - 1 PER 10,000 SF OFFICE, BIKE SPACE (LONG TERM) - 1 PER 5,000 SF OFFICE, MIN 4
BIKE SPACE (SHORT TERM) - 1 PER 5,000 SF RETAIL, BIKE SPACE (LONG TERM) - NONE
SHEET INDEEX
SHEET # SHEET NAME
C0.00 COVER SHEET
C1.00 OVERALL EXISTING CONDITIONS PLAN
C1.01 EXISTING CONDITIONS PLAN ENLARGEMENT
C2.00 DEMOLITION PLAN
C3.00 OVERALL SITE PLAN
C3.01 SITE PLAN ENLARGEMENT
C3.20 AMENITY AREA PLAN
C5.00 GRADING AND DRAINAGE PLAN
C5.01 BMP DETAILS
C6.00 UTILITIES PLAN
C9.00 SITE DETAILS
C9.01 SITE DETAILS
C9.02 SITE DETAILS
C9.03 SITE DETAILS
C9.04 SITE DETAILS
L1.00 LANDSCAPE PLAN
L2.00 PLANTING DETAILS
L2.01 PLANTING DETAILS
APPLICATION
(MANAGER)
(MANAGER)
498 674
ADMINISTRATIVE SITE REVIEW NOTES:
1. The required parking for the development will be accommodated through a combination of the required 211 proposed parking spaces on site andthe required 287 off-site parking spaces in the nearby Powerhouse Square parking deck (property PIN #1703498754).
2. The development anticipates providing more parking than the minimum required, for a total of 298 on-site parking spaces and 376 off-sitePowerhouse Square parking deck parking spaces. The new 376 off-site Powerhouse Square parking spaces do not require an administrative siteplan approval or a rezoning.
3. Staff reviewed the applicant's first submittal dated January 20, 2017 which included the three (3) level 376 parking space Powerhouse Squareparking deck expansion and determined in Staff's Review Cycle #1 Response dated February 8, 2017 that the Powerhouse Square parking deckexpansion qualifies as a renovation of an existing structure and therefore requires only that the applicant submit construction documents to theCity of Raleigh Inspections Department to receive a building permit.
4. No separate staff approval or other City of Raleigh authorization for the Powerhouse Square parking deck expansion is required.
W EDENTON ST
WE
ST
S
T
HILLSBOROUGH ST
PUBLIC R/W
(PRIMARY STREET)
N H
AR
RIN
GT
ON
S
T
℄
℄
℄
℄
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
400 H
SR-9-17
TRANS# 501332
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
BEACON PARTNERS
104 LAKE CLIFF COURT
CARY, NC 27513
T: 919-460-9786
F: 919-460-9878
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GTO
N S
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
NORTH
02.24.17 ADMIN. SITE RESUBMITTAL1
04.18.17 ADMIN. SITE RESUBMITTAL2
0 15 30 60
1"= 30'SCALE:
NORTH
Q
:\2
01
6\C
16
11
1 - 4
04
H
illsb
oro
ug
h S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
11
1-C
1.0
0-E
xistin
g C
on
ditio
ns.d
wg
A
pr 1
9, 2
01
7 - 2
:5
2p
m
OVERALL EXISTING
CONDITIONS PLAN
C1.00
C16111
2017.04.19
LAP
JWP
SURVEY STATEMENTOF ENCROACHMENTS
NOTES CORRESPONDING TO SCHEDULEB-SEC. II OF COMMITMENT No. 2016-00280(Revision #1 on February 3, 2016)
1
2
3
4
5
6
7
8
10
11
12
OHE
SURVEY FLOOD NOTE
SURVEY GENERAL NOTES
SURVEY MISCELLANEOUS NOTES
SURVEY LEGEND
SEE SHEET C2.01
FOR ENLARGEMENT
SEE SHEET C2.01
FOR ENLARGEMENT
W EDENTON ST
WE
ST
S
T
HILLSBOROUGH ST
PUBLIC R/W
(PRIMARY STREET)
N H
AR
RIN
GT
ON
S
T
℄
℄
℄
℄
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
400 H
SR-9-17
TRANS# 501332
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
BEACON PARTNERS
104 LAKE CLIFF COURT
CARY, NC 27513
T: 919-460-9786
F: 919-460-9878
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GTO
N S
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
NORTH
02.24.17 ADMIN. SITE RESUBMITTAL1
04.18.17 ADMIN. SITE RESUBMITTAL2
0 10 20 40
1"= 20'SCALE:
NORTH
Q
:\2
01
6\C
16
11
1 - 4
04
H
illsb
oro
ug
h S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
11
1-C
1.0
0-E
xistin
g C
on
ditio
ns.d
wg
A
pr 1
9, 2
01
7 - 2
:5
3p
m
EXISTING
CONDITIONS PLAN
ENLARGEMENT
C1.01
C16111
2017.04.19
LAP/RS
JWP
SURVEY STATEMENTOF ENCROACHMENTS
OHE
SURVEY LEGEND
W EDENTON ST
WE
ST
S
T
HILLSBOROUGH ST
PUBLIC R/W
(PRIMARY STREET)
N H
AR
RIN
GT
ON
S
T
H
Y
D
H
Y
D
UPUP
RAMP DOWN TO
PARKING BELOW
RAMP UP
UP
GR
AD
E A
T +
4%
: 1
45
'
DO
WN
GR
AD
E A
T -4
% : 1
65
'
DO
WN
GR
AD
E A
T -3
% : 1
60
'
UP
GR
AD
E A
T +
1.5
% : 1
55
PEDESTRIAN ROUTE FROM OFF-SITE PARKING
STRUCTURE TO PROPOSED BUILIDING 177'
33.00'
ROW
43.10'
B-B
36
.0
0'
RO
W
38
.8
8'
B-B
33.00'
ROW
42.22'
B-B
49
.5
0'
RO
W
60
.6
2'
B-B
GENERAL NOTES:
1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN COMPLIANCE WITH THE OFFICE OF STATE CONSTRUCTION, DEPARTMENT OF INSURANCE, NCDENR,
AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL GUIDELINES. ALL UTILITY CONSTRUCTION SHALL COMPLY WITH APPLICABLE LOCAL JURISDICTIONAL
STANDARDS AND SPECIFICATIONS.
2. EXISTING SURVEY INFORMATION INCLUDING TOPOGRAPHIC INFORMATION PROVIDED BY STEWART , UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES OR CONFLICTS.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING, COORDINATING AND PAYMENT FOR ALL NECESSARY LOCATING SERVICES INCLUDING INDEPENDENT
LOCATING SERVICES. THE CONTRACTOR SHALL PROVIDE NOTICE OF EXCAVATION TO NOTIFICATION CENTER AND FACILITY OWNERS (PER NC STATUTE) NO LESS
THAN 3 BUSINESS DAYS AND NO MORE THAN 12 WORKING DAYS PRIOR TO BEGINNING DEMOLITION, EXCAVATION OR ANY OTHER FORM OF CONSTRUCTION. THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES OR CONFLICTS. NO EXCAVATION OR DEMOLITION SHALL BE
STARTED WITHOUT ALL UTILITIES BEING LOCATED.
4. ALL SUB-SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON SURVEY INFORMATION
GATHERED FROM FIELD INSPECTION AND/OR ANY OTHER APPLICABLE RECORD DRAWINGS WHICH MAY BE AVAILABLE. THE CONTRACTOR SHALL IMMEDIATELY
NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES OR CONFLICTS.
5. EXISTING IMPROVEMENTS DAMAGED OR DESTROYED BY THE CONTRACTOR DURING CONSTRUCTION SHALL BE RESTORED OR REPLACED TO ORIGINAL CONDITION
AND TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE AT THE CONTRACTOR'S EXPENSE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND COORDINATING PERMITS, INSPECTIONS, CERTIFICATIONS AND OTHER REQUIREMENTS WHICH MUST
BE MET UNDER THIS CONTRACT.
7. THE CONTRACTOR SHALL MAINTAIN “AS-BUILT” DRAWINGS TO RECORD THE ACTUAL LOCATION OF ALL PIPING PRIOR TO CONCEALMENT, VALVE AND MANHOLE
CHANGES, AND HARDSCAPE OR LANDSCAPE CHANGES. DRAWINGS SHALL BE PROVIDED TO THE OWNER'S REPRESENTATIVE AT REGULAR INTERVALS, OR AS
REQUESTED THROUGHOUT THE PROJECT FOR RECORD KEEPING.
8. IF DEPARTURES FROM THE PROJECT DRAWINGS OR SPECIFICATIONS ARE DEEMED NECESSARY BY THE CONTRACTOR, DETAILS OF SUCH DEPARTURES AND
REASONS THERE OF SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR REVIEW. NO DEPARTURES FROM THE CONTRACT DOCUMENTS SHALL BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE OWNER'S REPRESENTATIVE.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY EXISTING UTILITY LINES REQUIRED TO COMPLETE ANY PORTION OF CONSTRUCTION. THE
CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE COORDINATION AND COSTS OF THE RELOCATION AND ASSOCIATED WORK.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE PREMISES FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND RUBBISH CAUSED BY THE
CONTRACTOR. ALL DEBRIS SHALL BE REMOVED FROM THE PROJECT SITE ON A DAILY BASIS.
11. THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND/OR METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE
PLANS.
12. ROADWAYS (TEMPORARY OR PERMANENT) MUST BE CAPABLE OF SUPPORTING FIRE FIGHTING APPARATUS (85,000 LBS) DURING ALL PHASES OF CONSTRUCTION
ONCE VERTICAL CONSTRUCTION HAS BEGUN.
SITE NOTES:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF THE CONSTRUCTION LAYDOWN AREA, PERIMETER FENCE, AND
ASSOCIATED GATES. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE REMOVAL OF THE CONSTRUCTION LAYDOWN AREA PERIMETER FENCE AND
ASSOCIATED GATES AT THE COMPLETION OF THE PROJECT.
2. THE CONTRACTOR SHALL REFERENCE THE DESIGN PLANS FOR DIMENSIONS, JOINT LOCATIONS, AND INLAY SPECIFICATIONS NEAR BUILDINGS AND IN
COURTYARDS. CONTRACTOR SHALL PROVIDE JOINTS IN WALKWAYS AND HARDSCAPE PER DETAILS OR AS INDICATED ON LANDSCAPE/HARDSCAPE PLAN
SHEETS.
OR
THE CONTRACTOR SHALL REFERENCE THE ARCHITECTURAL PLANS FOR DIMENSIONS, JOINTS AND INLAY SPECIFICATIONS NEAR THE BUILDING AND
COURTYARD. THE CONTRACTOR SHALL PROVIDE JOINTS IN WALKWAYS EVERY TEN (10) FEET MAXIMUM, OR AS INDICATED ON ARCHITECTURAL PLANS
SHEETS.
3. ALL CONSTRUCTION TRAFFIC SHALL ENTER SITE FROM ______ UNLESS OTHERWISE APPROVED IN WRITING FROM THE OWNER'S REPRESENTATIVE FOR AN
ALTERNATE POINT OF ACCESS.
4.REFER TO ARCHITECTURAL PLANS FOR BUILDING INFORMATION.
5. ALL DIMENSIONS ARE IN DECIMAL FEET TO OUTSIDE FACE OF BUILDINGS, TO CENTERLINES, AND/OR FACE OF CURB UNLESS OTHERWISE NOTED.
6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATES AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE PRIOR TO
ANY CONSTRUCTION.
7. ALL WRITTEN DIMENSIONS SHALL PREVAIL. DO NOT SCALE FROM DRAWINGS.
8. ALL UTILITIES WITH SURFACE ACCESS SHALL BE LOCATED WITHIN THE PAVING PATTERN AND SHALL BE COORDINATED WITH LANDSCAPE ARCHITECT PRIOR
TO CONSTRUCTION. REFER TO LAYOUT DRAWINGS.
9. ALL ANGLES ARE 90 DEGREES UNLESS OTHERWISE NOTED.
10. ALIGN ALL JOINTS, CORNERS, AND EDGES AS SHOWN
11. CONTRACTOR SHALL REFER TO AND COORDINATE WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS AT ALL TIMES PRIOR TO AND DURING
CONSTRUCTION.
12. ALL CURB TAPERS ARE SIX (6') FEET LONG UNLESS OTHERWISE SHOWN ON PLAN.
13. WHERE NEW SIDEWALK ADJOINS EXISTING WALK, PROVIDE EXPANSION JOINT BY DRILLING INTO THE FACE OF THE EXISTING WALK FOR PLACEMENT OF
DOWELS. TIE NEW SIDEWALKS INTO NEAREST EXISTING PAVEMENT JOINT; MATCH WIDTH OF EXISTING WALKWAY.
14. WHERE SIDEWALK OR WALKWAYS ARE ADJACENT TO PARKING SPACES THE WALKWAY SHALL BE A MINIMUM 6.5' WIDE AS MEASURED FROM THE FACE OF
CURB.
15. MAXIMUM RUNNING SLOPE FOR WALKING SURFACES CANNOT BE GREATER THAN 1:20 AND CROSS SLOPES CANNOT BE GREATER THAN 1:48. HANDICAP
SPACES SURFACE SLOPES SHALL NOT EXCEED 1:48 IN ALL DIRECTIONS.
16. SIGHT TRIANGLES - NOTHING OVER 30" HIGH SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLES.
17. THE SITE SHALL BE FULLY STABILIZED (90% COVERAGE) PRIOR TO ISSUANCE OF A BUILDING CERTIFICATE OF OCCUPANCY OR PROJECT APPROVAL
18. HANDICAP RAMPS SHALL BE INSTALLED PER LATEST EDITION OF THE NC BUILDING CODE AND ANSI 117.11 WITH DETECTABLE WARNING DOMES WITH A
COLOR CONTRAST OF 70% MINIMUM. SEE DETAILS AND GRADING SPOT ELEVATIONS, IF THE EXISTING CONDITIONS PRECLUDE THE ABILITY TO PROVIDE A
MAXIMUM SLOPE 1/12 FOR 6-FEET OR A MAXIMUM CROSS SLOPE OF 1:48 AND A 36” MINIMUM LANDING, THE CONTRACTOR SHALL NOTIFY ENGINEER OR
OWNER REPRESENTATIVE PRIOR TO INSTALLATION.
19. THE TESTING AGENCY SHALL BE RESPONSIBLE FOR PROVIDING THE ASPHALT AND CONTRACTOR CERTIFICATION MEMO TO NCDOT FOR ALL ROADWAY
IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.
SIGNAGE, STRIPING, AND MARKING NOTES:
1. ALL INTERNAL SIGNAGE SHALL BE COORDINATED WITH OWNER FOR ACTUAL LOCATION AT TIME OF INSTALLATION. SIGNAGE LEADING ONTO PUBLIC
THOROUGHFARE SHALL BE INSTALLED AT RIGHT OF WAY PER DOT STANDARDS
2. ALL PAVEMENT STRIPING (EXCEPT INDIVIDUAL PARKING BAY STRIPING) SHALL BE THERMOPLASTIC REFLECTIVE PAINT. MATERIALS AND DIMENSIONS SHALL
CONFORM TO NCDOT STANDARDS AND SPECIFICATIONS. PARKING BAY STRIPING SHALL BE WHITE REFLECTIVE PAINT.
3. CROSSWALKS SHALL BE CONSTRUCTED OF THERMOPLASTIC MATERIALS AND CONSTRUCTED IN ACCORDANCE WITH STATE DOT SPECIFICATIONS. CONTRACTOR TO
INSTALL CROSSWALKS IN SUCH A MANNER THAT CROSSWALKS ARE ALIGNED BETWEEN HANDICAP/WALKWAY ACCESS POINTS OR PERPENDICULAR TO THE
ROADWAY / DRIVE LANE.
4. ADA SYMBOLS SHOWN THESE DRAWINGS ARE FOR LOCATION PURPOSES ONLY AND NOT INTENDED TO BE PAINTED. CONTRACTOR RESPONSIBLE FOR INSTALLING
ALL REQUIRED ADA SIGNAGE
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
400 H
SR-9-17
TRANS# 501332
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
BEACON PARTNERS
104 LAKE CLIFF COURT
CARY, NC 27513
T: 919-460-9786
F: 919-460-9878
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GTO
N S
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
NORTH
02.24.17 ADMIN. SITE RESUBMITTAL1
04.18.17 ADMIN. SITE RESUBMITTAL2
Q
:\2
01
6\C
16
11
1 - 4
04
H
illsb
oro
ug
h S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
11
1-C
3.0
0-S
ite
P
la
n.d
wg
A
pr 1
9, 2
01
7 - 2
:5
3p
m
OVERALL SITE PLAN
C3.00
C16111
2017.04.19
LAP/MDS
JWP
0 15 30 60
1"= 30'SCALE:
NORTH
PROPOSED BUILDING
PROPOSED CONCRETE SIDEWALK
PROPOSED BRICK SIDEWALK
PROPOSED MODULAR PAVING
PROPOSED TREE/TRENCH GRATE
PROPOSED CURB & GUTTER
PROPOSED CROSSWALK
PROPOSED 6' WIDE STANDARD CROSSWALK
PROPOSED 10' WIDE HIGH VISIBILITY CROSSWALK
PROPOSED SIGN
PROPOSED LIGHT
PROPOSED BIKE RACK
PROPOSED BOLLARD
LIMITS OF DISTURBANCE
SITE LEGEND
SEE SHEET C3.01
FOR ENLARGEMENT
SEE SHEET C2.01
FOR ENLARGEMENT
Sheet:
PROPOSED STAIR
ADMINISTRATIVE SITE REVIEW NOTES:
1. The required parking for the development will be accommodated through a combination of the required 211 proposedparking spaces on site and the required 287 off-site parking spaces in the nearby Powerhouse Square parking deck (propertyPIN #1703498754).
2. The development anticipates providing more parking than the minimum required, for a total of 298 on-site parking spaces and376 off-site Powerhouse Square parking deck parking spaces. The new 376 off-site Powerhouse Square parking spaces do notrequire an administrative site plan approval or a rezoning.
3. Staff reviewed the applicant's first submittal dated January 20, 2017 which included the three (3) level 376 parking spacePowerhouse Square parking deck expansion and determined in Staff's Review Cycle #1 Response dated February 8, 2017 thatthe Powerhouse Square parking deck expansion qualifies as a renovation of an existing structure and therefore requires onlythat the applicant submit construction documents to the City of Raleigh Inspections Department to receive a building permit.
4. No separate staff approval or other City of Raleigh authorization for the Powerhouse Square parking deck expansion isrequired.
W EDENTON ST
WE
ST
S
T
HILLSBOROUGH ST
PUBLIC R/W
(PRIMARY STREET)
N H
AR
RIN
GT
ON
S
T
H
Y
D
H
Y
D
RAMP DOWN TO
PARKING BELOW
RAMP UP
ADA RAMP PER
CITY OF RALEIGH
STD. 20.11 (TYP.)
PARKING
GARAGE
ENTRANCE
27.28'
DR
IV
EW
AY
10.00' CLEAR
PRIMARY STREET
ENTRANCE (TYP.)
RETAIL USE
SH (BUILD-TO)
BOUNDARY
SH (BUILD-TO) BOUNDARY
HILLSBOROUGH STREET
83% LOT WIDTH W/ FACADE
UP
GR
AD
E A
T +
4%
: 1
45
'
DO
WN
GR
AD
E A
T -4%
: 165'
DO
WN
GR
AD
E A
T -3%
: 160'
UP
GR
AD
E A
T +
1.5%
: 155
ADA RAMP PER
CITY OF RALEIGH
STD. 20.11 (TYP.)
ADA RAMP PER
CITY OF RALEIGH
STD. 20.11 (TYP.)
PRIMARY STREET
ENTRANCE (TYP.)
PRIMARY STREET
ENTRANCE (TYP.)
PRIMARY STREET
ENTRANCE (TYP.)
PRIMARY STREET
ENTRANCE (TYP.)
PRIMARY STREET
ENTRANCE (TYP.)
ADA RAMP PER
CITY OF RALEIGH
STD. 20.11 (TYP.)
RETAIL USE
RETAIL USE
24.88'
DR
IV
EW
AY
TREE GRATE PER
CITY OF RALEIGH
STANDARD (TYP.)
MODULAR PAVING
(TYP.)
CONCRETE PAVING
(TYP.)
TREE GRATE PER
CITY OF RALEIGH
STANDARD (TYP.) W/
TRENCH DRAIN
MODULAR PAVING
(TYP.)
CONCRETE PAVING
(TYP.)
TREE GRATE PER
CITY OF RALEIGH
STANDARD (TYP.)
CONCRETE PAVING
(TYP.)
TREE GRATE PER
CITY OF RALEIGH
STANDARD (TYP.)
CONCRETE PAVING
(TYP.)
BRICK PAVING
(TYP.)
CONCRETECURB
AND GUTTER (TYP.)
CONCRETE CURB AND GUTTER
(TYP.)
TREE GRATE PER
CITY OF RALEIGH
STANDARD (TYP.)
CONCRETE STEPS (TYP.)
HANDRAIL (TYP.)
6.00'
CONCRETE SEAT WALL
(TYP.)
MONUMENTAL CONCRETE
SEATING (TYP.)
15.00' B
UILD
-T
O
10.50' C
LE
AR
7.00'
(T
YP
.)
10.00' CLEAR
6.00'
12.00' C
LE
AR
6.00'
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
25 CU YD CMPCTR
25 CU YD CMPCTR 12' X 30' LOADING BERTH
12' X 30' LOADING BERTH
12' X 30' LOADING BERTH
33.00'
ROW
43.10'
B-B
36.00'
RO
W
38.88'
B-B
33.00'
ROW
42.22'
B-B
49.50'
RO
W
60.62'
B-B
42.38'
DR
IV
EW
AY
2.50'
(T
YP
.)
10.00'
2.50'
(T
YP
.)
10.00'
20.00'
(TYP.)
30.00'
PLANTING AREA
(TYP.)
10.50'10.00'
6.00'
BIKE RACKS (TYP.)
CAPACITY (6)
BIKE RACKS
CAPACITY (6)
(TYP.)
SH (BUILD-TO) BOUNDARY
N. HARRINGTON STREET
100% LOT WIDTH W/ FACADE
SH (BUILD-TO)
BOUNDARY
SH (BUILD-TO) BOUNDARY
WEST STREET 0% LOT WIDTH
W/ FACADE (DESIGN ADJUSTMENT
UNDER REVIEW)
22'
(TYP.)
8'
(T
YP
.)
22'
(T
YP
.)
8'
(TYP.)
3.50' PUBLIC ACCESS
SIDEWALK EASEMENT
3.50' PUBLIC
ACCESS SIDEWALK
EASEMENT
NOTES:
1. SEE SHEET C3.00 FOR GENERAL AND SITE NOTES.
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
400 H
SR-9-17
TRANS# 501332
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
BEACON PARTNERS
104 LAKE CLIFF COURT
CARY, NC 27513
T: 919-460-9786
F: 919-460-9878
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GTO
N S
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
NORTH
02.24.17 ADMIN. SITE RESUBMITTAL1
04.18.17 ADMIN. SITE RESUBMITTAL2
Q
:\2
01
6\C
16
11
1 - 4
04
H
illsb
oro
ug
h S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
11
1-C
3.0
0-S
ite
P
la
n.d
wg
A
pr 1
9, 2
01
7 - 2
:5
3p
m
SITE PLAN
ENLARGEMENT
C3.01
C16111
2017.04.19
MDS/RS
JWP
0 10 20 40
1"= 20'SCALE:
NORTH
PROPOSED BUILDING
PROPOSED CONCRETE SIDEWALK
PROPOSED BRICK SIDEWALK
PROPOSED MODULAR PAVING
PROPOSED TREE/TRENCH GRATE
PROPOSED CURB & GUTTER
PROPOSED CROSSWALK
PROPOSED 6' WIDE STANDARD CROSSWALK
PROPOSED 10' WIDE HIGH VISIBILITY CROSSWALK
PROPOSED SIGN
PROPOSED LIGHT
PROPOSED BIKE RACK
PROPOSED BOLLARD
LIMITS OF DISTURBANCE
SITE LEGEND
15.00'
H
Y
D
H
Y
D
W EDENTON ST
WE
ST
S
T
HILLSBOROUGH ST
PUBLIC R/W
(PRIMARY STREET)
N H
AR
RIN
GT
ON
S
T
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSSSSS
S
S
S
S
S
S
S
S
SSSSSSSS
D
MH-02
RIM ELEV = 336.19
INV IN = 332.66
INV IN = 331.66
INV OUT = 331.66
TRAP-01
RIM ELEV = 337.26
INV IN = 333.38
INV OUT = 332.42
7
1
L
F
8
"
P
V
C
@
5
.
7
4
%
6 LF 8" PVC @ 1.00%
34 LF 8" PVC @ 2.25%
6 LF 8" PVC @ 1.74%
29 LF 8" PVC @ 11.49%
39 LF 8" PVC @ 6.50%
WM
WM
W
W
W
BUILDING CONNECTION
CITY OF RALEIGH APPROVED
RPZ BACKFLOW IN BUILDING
BUILDING CONNECTION
CITY OF RALEIGH APPROVED
RPDA BACKFLOW IN BUILDING
16"X8" TEE AND VALVE
16"X6" TEE AND VALVE
8" D
IP
6" D
IP
CITY OF RALEIGH 4" WATER
METER AND METER VAULT
(TYP)
8" FIRE SUPPRESSION
WATERLINE
6" DIP
6"X6" TS&V
8" CORE AND BOOT
CONNECTION TO
EXISTING MANHOLE
8" CORE AND BOOT
CONNECTION TO
EXISTING MANHOLE
8" CORE AND BOOT
CONNECTION TO
EXISTING MANHOLE
D
D
D
D
EX MH-01
RIM ELEV = 336.31
INV IN = 327.59
PROPOSED
FIRE HYDRANT
EXISTING FIRE HYDRANT TO REMAIN
FIRE FLOW TEST ON 09/20/16 WITH
FIRE MARSHALL STEVE BERRY
FLOW = 1035 GPM
EXISTING FIRE HYDRANT TO REMAIN
FIRE FLOW TEST ON 09/20/16 WITH
FIRE MARSHALL STEVE BERRY
STATIC = 60 PSI
RESIDUAL = 57 PSI
EXISTING FIRE
HYDRANT TO REMAIN
FDC
FDC
FIRE DEPARTMENT
CONNECTION (TYP)
ABANDON UTILITY STUBS
PER CITY OR RALEIGH PUBLIC
UTILITY DEPARTMENT PROCEDURES
(TYP)
ABANDON UTILITY STUBS
PER CITY OR RALEIGH PUBLIC
UTILITY DEPARTMENT PROCEDURES
(TYP)
WW
W WW
W WW W
WW W
WW W
WW W
W WW
16" DIP
16"X8" TEE AND VALVE
16" BUTTERFLY VALVE
INSTALLED IN 5' MANHOLE (TYP)
8"X8" TS&V
16"X8" TEE
8"X8" TS&V
16"X8" TEE
BLIND FLANGE
BLIND FLANGE
BUILDING CONNECTION
CITY OF RALEIGH APPROVED
RPDA BACKFLOW IN BUILDING
8" D
IP
8" FIRE SUPPRESSION
WATERLINE
D
S
S
S
S
S
S
S
S
FIRM LICENSE #: C-1051
www.stewartinc.com
PROJECT #: C16111
101 N. TRYON ST., SUITE 1400
CHARLOTTE, NC 28202
T 704.334.7925
Client:
Vicinity map:
Issued for:
Title:
Sheet:Project number:
Date:
Drawn by:
Approved by:
Project:
400 H
SR-9-17
TRANS# 501332
Date Description
ADMINISTRATIVE SITE
REVIEW
No.
Seal:
BEACON PARTNERS
104 LAKE CLIFF COURT
CARY, NC 27513
T: 919-460-9786
F: 919-460-9878
PRELIMINARY - DO NOT
USE FOR CONSTRUCTION
N W
ES
T S
T
W EDENTON ST
HILLSBOROUGH ST
N H
AR
RIN
GTO
N S
W MORGAN ST
CS
X R
AILR
OA
D
W JONES ST
S D
AW
SO
N S
T
W HARGETT ST
GLE
NW
OO
D A
VE
S M
cD
OW
ELL S
T
NORTH
02.24.17 ADMIN. SITE RESUBMITTAL1
04.18.17 ADMIN. SITE RESUBMITTAL2
NORTH
UTILITY LEGEND
EXISTING WATER LINE
PROPOSED WATER LINE
EXISTING SANITARY SEWER LINE
PROPOSED SANITARY SEWER LINE
PROPOSED FIRE HYDRANT
PROPOSED WATER VALVE
EXISTING SANITARY SEWER MANHOLE
PROPOSED SANITARY SEWER MANHOLE
PROPOSED CLEANOUT
PROPOSED FDC
PROPOSED BACKFLOW METER
PROPOSED POST INDICATOR VALVE (PIV)
GREASE INTERCEPTOR
300' HYDRANT COVERAGE CIRCLE
LIMITS OF DISTURBANCE
FDC
CO
H
Y
D
PIV
S
W
SS
WATER NOTES:
1. AS INDICATED, ALL WATERLINES SHALL BE DUCTILE IRON PIPE MEETING THE REQUIREMENTS OF ANSI-AWWA C151 PRESSURE CLASS 350 OR SOFT COPPER TYPE K PIPE PER ASTM B88. IF PVC WATERLINE IS INDICATED ON
THE PLANS IT SHALL MEET THE REQUIREMENTS OF AWWA C-900; CLASS 200.
2. ALL WATERLINES SHALL HAVE A MINIMUM OF 3.5 FEET OF COVER.
3. TESTING NOTES:
PRESSURE:
LEAKAGE SHALL NOT EXCEED THE MAXIMUM ALLOWABLE LEAKAGE SPECIFIED IN AWWA C 600. MINIMUM TEST PRESSURE SHALL BE 150 PSI FOR DOMESTIC AND 200 PSI FOR FIRE PROTECTION.
BACTERIOLOGICAL:
TWO SAMPLES FOR BACTERIOLOGICAL SAMPLING SHALL BE COLLECTED AT LEAST 24 HOURS APART. IF CONTAMINATION IS INDICATED, THEN THE DISINFECTION PROCEDURE AND TESTING SHALL BE REPEATED UNTIL
SATISFACTORY RESULTS ARE OBTAINED.
4. THE CHLORINE IN HEAVILY CHLORINATED WATER FLUSHED FROM MAINS NEEDS TO BE NEUTRALIZED BEFORE DISCHARGE. CONTRACTORS SHALL NEUTRALIZE HEAVILY CHLORINATED WATER FLUSHED FROM MAINS PRIOR
TO DISCHARGE OR TRANSPORT ALL HEAVILY CHLORINATED WATER OFFSITE FOR PROPER DISPOSAL.
5. PAINT VALVE COVERS, FIRE HYDRANTS AND OTHER WATER APPARATUS TO MEET THE LOCAL JURISDICTIONAL REQUIREMENTS.
SEWER NOTES:
1. SANITARY SEWER CLEANOUTS LOCATED IN PAVEMENT AREAS SHALL BE HEAVY DUTY TRAFFIC BEARING CASTINGS.
2. UNLESS OTHERWISE NOTED, ALL SANITARY SEWER MANHOLES ARE 4' DIA.
3. MANHOLES LOCATED IN PAVEMENT, CONCRETE OR OTHER TRAFFIC AREAS SHALL BE SET AT GRADE. MANHOLES LOCATED IN OTHER AREAS (I.E. GRASS OR
WOODED AREAS) SHALL HAVE THEIR RIMS RAISED SIX INCHES ABOVE THE SURROUNDING GRADE. MANHOLES SUBJECT TO POSSIBLE WATER INFILTRATION
SHALL HAVE WATERTIGHT, BOLTED LIDS.
4. MINIMUM REQUIRED SLOPES FOR SEWER SERVICES:
4" SEWER SERVICE - 2.00% SLOPE
6" SEWER SERVICE - 1.00% SLOPE
8" SEWER SERVICE - 0.50% SLOPE
5. UNLESS OTHERWISE NOTED, LOCATE SANITARY SERVICE CLEANOUTS AT ALL HORIZONTAL OR VERTICAL CHANGES IN DIRECTION. MAXIMUM SPACING
BETWEEN CLEANOUTS SHALL BE 75 FEET.
6. SEWER LINES LESS THAN 3 FEET OF COVER SHALL BE CLASS 50 DUCTILE IRON PIPE. SEWER LINES WITH GREATER THAN 3 FEET OF COVER SHALL BE AS
NOTED BELOW:
4" SEWER SERVICE - SCH 80
6" SEWER SERVICE - SCH 80
8" SEWER SERVICE - SDR-35
7. SEWER LINES UNDER CONSTRUCTION SHALL BE PROTECTED FROM DIRT, DEBRIS OR OTHER CONTAMINANTS ENTERING THE NEW SYSTEM. A MECHANICAL
PLUG SHALL BE UTILIZED BOTH IMMEDIATELY UPSTREAM OF THE NEW CONSTRUCTION AND AT THE FIRST MANHOLE DOWNSTREAM IN THE EXISTING
SYSTEM. EXISTING STRUCTURES, PIPING AND APPURTENANCES SHALL BE PROTECTED FROM ANY INFLOW OF WATER, DIRT OR DEBRIS DUE TO NEW
CONSTRUCTION CONNECTING TO OR IN THE VICINITY OF THE EXISTING SYSTEM. CONTRACTOR TO REMOVE DEBRIS AND PLUG PRIOR TO OCCUPANCY.
8. ALL MANHOLES COVERS SHALL BE PAINTED TO LOCAL JURISDICTIONAL REQUIREMENTS.
UTILITY NOTES:
1. REFER TO SHEET C3.00 FOR GENERAL NOTES.
2. UNLESS OTHERWISE NOTED, ALL MANHOLES SHALL BE PRE-CAST CONCRETE STRUCTURES.
3. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF UNDERGROUND UTILITIES (WATER, SEWER, STORM, ELECTRICAL, GAS, OR OTHER) FOR
THIS PROJECT WITH THE BUILDING PLANS. THE UTILITY CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE INSTALLATION OF ALL UTILITY SERVICES TO
WITHIN FIVE (5) FEET OF THE BUILDING CONNECTION POINT.
4. THE CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS ON SITE AND UTILITY PROVIDERS DURING CONSTRUCTION TO ENSURE SMOOTH
TRANSITION BETWEEN DISCIPLINES.
5. THE CONTRACTOR SHALL COORDINATE ALL PEDESTRIAN AND VEHICULAR INTERRUPTIONS WITH OWNER'S REPRESENTATIVE AT LEAST 72 HOURS PRIOR TO
BEGINNING WORK.
6. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK INSIDE THE PUBLIC RIGHT OF WAY PRIOR TO RECEIPT AND COMPLIANCE WITH ALL APPLICABLE
NCDOT PERMITS. ADDITIONALLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FLAGGERS AND TRAFFIC CONTROL DURING
ALL WORK INSIDE THE PUBLIC RIGHTS OF WAY.
7. THE CONTRACTOR SHALL NOT RE-USE ANY FIRE HYDRANT REMOVED AS PART OF THIS PROJECT. ANY FIRE HYDRANT SHOWN TO BE REMOVED OR
RELOCATED SHALL BE REPLACED WITH A NEW FIRE HYDRANT MEETING THE LOCAL JURISDICTIONAL REQUIREMENTS AND STANDARDS.
8. ALL EXISTING SUB-SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATION BASED ON SURVEY
INFORMATION GATHERED FROM FIELD INSPECTION AND/OR ANY OTHER APPLICABLE RECORD DRAWINGS WHICH MAY BE AVAILABLE. DEPTHS OF EXISTING
UTILITIES SHOWN IN PROFILE VIEWS ARE BASED ON STANDARD ASSUMPTIONS. THE CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION, DEPTH, SIZE
AND MATERIAL OF ANY AND ALL SUB-SURFACE CONDITIONS REFERENCED IN THESE PLANS PRIOR TO ANY EXCAVATION OR CONSTRUCTION ACTIVITY. THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES OR CONFLICTS.
9. ELEVATIONS OF UTILITIES ARE GIVEN TO THE EXTENT OF INFORMATION AVAILABLE, WHERE ELEVATIONS ARE NOT GIVEN AT POINTS OF EXISTING UTILITY
CROSSINGS, SUCH ELEVATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND REPORTED TO THE ENGINEER, WHEN UNKNOWN LINES ARE EXPOSED,
THEIR LOCATIONS AND ELEVATIONS SHALL ALSO BE REPORTED TO THE ENGINEER.
10. UNDERGROUND UTILITIES SHOWN ON THIS PLAN SHALL BE INSTALLED PRIOR TO ANY CONSTRUCTION OF PARKING AREA, DRIVES, CURB AND GUTTER OR
CONCRETE WALKS / PADS. IF UTILITIES SHOWN ON THIS PLAN CANNOT BE INSTALLED PRIOR TO INSTALLATION OF IMPERVIOUS (ASPHALT / CONCRETE)
CONDUIT SHALL BE INSTALLED FOR THE “FUTURE” UTILITY INSTALLATION.
11. AS-BUILT DOCUMENTATION REQUIREMENTS: PRIOR TO APPROVAL FROM LOCAL JURISDICTION OR ENGINEER THE CONTRACTOR SHALL PROVIDE AS-BUILT
DRAWINGS (IN BOTH PAPER AND ELECTRONIC FORMAT (CAD / PDF) PREPARED AND SEALED BY A PROFESSIONAL LAND SURVEYOR SHOWING ALL UTILITY
INSTALLATION. HORIZONTAL AND VERTICAL INFORMATION SHALL BE PROVIDED FOR WATER, SEWER, STORM INCLUDING ALL STRUCTURES, VALVES,
HYDRANTS, AND OTHER APPURTENANCES.
PROPOSED UTILITY SEPARATION:
1. WATER MAINS SHALL BE LAID AT LEAST 10 FEET HORIZONTALLY FROM EXISTING OR PROPOSED SEWERS, UNLESS LOCAL CONDITIONS OR BARRIERS
PREVENT A 10-FOOT HORIZONTAL SEPARATION IN WHICH CASE;
a. THE WATER MAIN IS LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP OF
THE SEWER; OR
b. THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER WITH THE WATER MAIN LOCATED AT ONE SIDE OF A BENCH OF UNDISTURBED EARTH,
AND WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP TO THE SEWER.
2. CROSSING A WATER MAIN OVER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS OVER A SEWER, THE WATER MAIN SHALL BE LAID AT
SUCH AN ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER, UNLESS LOCAL CONDITIONS OR
BARRIERS PREVENT AN 18 INCH VERTICAL SEPARATION, IN WHICH CASE BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF FERROUS
MATERIALS AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE POINT OF
CROSSING.
3. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND
THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET
ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING.
SEPARATION OF SANITARY SEWERS AND STORM SEWERS:
1. A 24" VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND SANITARY SEWER LINES OR BOTH THE SANITARY AND THE STORM LINES
SHALL BE CONSTRUCTED OF FERROUS MATERIALS.
Q
:\2
01
6\C
16
11
1 - 4
04
H
illsb
oro
ug
h S
tre
et\D
WG
S\1
- D
esig
n\S
he
ets\C
16
11
1-C
6.0
0-U
tility P
la
n.d
wg
A
pr 1
9, 2
01
7 - 2
:5
5p
m
UTILITIES PLAN
C6.00
C16111
2017.04.19
LAP
JWP
0 10 20 40
1"= 20'SCALE: