SP/SF Series Flow Switches - APlus Finetekaplusfine.com/.../01/SPSF-SERIES-FLOW-SWITCHES.pdf · 1....
Transcript of SP/SF Series Flow Switches - APlus Finetekaplusfine.com/.../01/SPSF-SERIES-FLOW-SWITCHES.pdf · 1....
Aplus Finetek Sensor, Inc.
More than just another level measurement company ….
ISO-9001:2000 certified
SP/SF Series Flow Switches
PRODUCT INTRODUCTION – SP SERIES
1
The SP Series is a thermal dispersion type flow switch. The SP is a precise flow sensing device whose principle of operation is heat diffusion. The SP series sensing probe incorporates two primary components. One component is a heated sensor with power applied to it. The second component measures the temperature emitted from the heated sensor. When the fluid is flowing a temperature difference will exist between the two sensor components. This temperature difference has an inverse relationship with the fluid flow velocity, e.g.the faster the fluid flows, the greater the temperature difference will be and vice versa. This method of flow sensing is accurate and highly reliable given the absence of any moving parts, which minimizes wear and tear.
OPERATING PRINCIPLE – SP SERIES
FEATURES•
and tear of moving parts compared to paddle type flow switches.
• Choice of wetted materials for a wide range of applications.
• Can be set for use with a wide range of liquids having different densities and amount of impurities.• Extended probe lengths up to 7.9” (200mm).• Local LED indication• Adjustable sensitivity and alarm setpoint.• Solidstate NPN/PNP or Relay outputs available.• Explosionproof version available.
Higher sensitivity, less installation limits and no wear
INDUSTRY USE• • Chilling systems, coolant pipes• Petrochemical• Marine shipboard• Food and beverage• Pharmaceutical• Optical systems• Semiconductor manufacturing • Fluid transport pipes, for flow control• Other industries
Hydroelectric power generation
2
Water: 0.032~4.92ft/s (1~150cm/s)Oil: 0.0984~9.84ft/s (3~300cm/s)
19~30VDC
304SS / 316SS / 316LSS
IP67
304SS / 316SS / 316LSS
Approx. 10s
-4⁰F~176⁰F (-20⁰C~80⁰C)
1,445psi (100bar)
-4⁰F~176⁰F (-20⁰C~80⁰C)
Process temp.
Ambient temp.
Type
Pressure
LED indication
Alarm output
Housing material
Housing rating
Wetted material
Warm-up time
Measuring range
Process connection
Accessory
Drawings
M12 Connector; 3-wire NPN or PNP, Power – brown,Grounding – blue, Output – black;
4-wire Relay SPST N.O. or N.C., Power – brown, Grounding – blue, Output – green and black
Flow velocity below setpoint – Red LED onFlow velocity equals setpoint – Yellow LED on
Flow velocity above setpoint – 1 thru 4 Green LED’s on to indicate flow velocity
Power supply
SP200-Compact
9-99-9-9(9999) SP201Extension
-9-99-9-9(9999)
1/2"PF1.22(31)
HEX38
2.85(72.5)
2.34(59.5)
M12
SP202High Temperature-9-99-9-9(9999)
LMax.7.87 (Max.200)
HEX38
M12
G 1/2"f0.630
( 16)f
1.59(40.5)
1.22(31)
HEX38
f0.291(f7.4)
M12
G 1/2"
NPN or PNP, 400mA; Relay SPST, N.O. or N.C., 0.3A@125VAC/1A@30VDC£
Output / elec. conn.
TYPES & SPECIFICATIONS – SP SERIES
1.59(40.5)
f0.291(f7.4)
f0.291(f7.4)
-4⁰F~248⁰F (-20⁰C~120⁰C)
Approx. 15s
Gasket, M12 Electrical Cable 2m Length
1/2 1/2 1/4”G, ”NPT, ”G 1/2 1/2”G, ”NPT 1/2 1/2 1/4”G, ”NPT, ”G
Units: Inch/mm
3
Water: 0.032~4.92ft/s (1~150cm/s)Oil: 0.0984~9.84ft/s (3~300cm/s)
Approx. 15s
-4⁰F~176⁰F (-20⁰C~80⁰C)
1,445psi (100bar)
Process temp.
Ambient temp.
Type
Pressure
LED indication
Alarm output
Housing material
Housing rating
Wetted material
Warm-up time
Measuring range
Process connection
Accessory
Drawings
Flow velocity below setpoint – Red LED onFlow velocity equals setpoint – Yellow LED on
Flow velocity above setpoint – 1 thru 4 Green LED’s on to indicate flow velocity
Power supply
SP220-Economy
9-99-9-9(9999)
Output / elec. conn.
TYPES & SPECIFICATIONS – SP SERIES
Gasket, M12 Electrical Cable 2m Length
1/2 1/2”G, ”NPT
-4⁰F~176⁰F (-20⁰C~80⁰C)
19~30VDC
Polycarbonate
IP65
304SS / 316SS / 316LSS
NPN or PNP, 400mA; Relay SPST, N.O. or N.C.
0.3A@125VAC/1A@30VDC
£
Note: Sensitivity and alarm setpoint are NOT adjustable with Economy type.
f0.291(f7.4)
1.18(30)
0.78(19.8)
1.22(31)
4.17(106)
1.57(40)
M12
1/2"PF
SP210-Stainless Steel9-99-9-9(9999)
1.22(31)
f1.50(f38)
f3.07(f78)
Sight Window
1.81(46)
PG
1.26(32)
f0.291(f7.4)
G1/2"
3.07(78)
SPDT Relay 5A@250VAC
M12 Connector; 3-wire NPN or PNP, Power – brown, Grounding – blue, Output – black; 4-wire Relay SPST,
N.O. or N.C. Power – brown, Grounding – blue,
Output – green and black
304SS
IP67
Units: Inch/mm
NC C NOF G
5 Pole Terminal Block
Output / elec. conn.
4
Water: 0.032~4.92ft/s (1~150cm/s)Oil: 0.0984~9.84ft/s (3~300cm/s)
19~30VDC
IP67
304SS / 316SS / 316LSS
-4⁰F~176⁰F (-20⁰C~80⁰C)
1,445psi (100bar)
-4⁰F~176⁰F (-20⁰C~80⁰C)
Process temp.
Ambient temp.
Type
Pressure
LED indication
Alarm output
Housing rating
Wetted material
Warm-up time
Measuring range
Process connection
Drawings
304SS
Flow velocity below setpoint – Red LED onFlow velocity equals setpoint – Yellow LED on
Flow velocity above setpoint – 1 thru 4 Green LED’s on to indicate flow velocity
Power supply
SP170Explosionproof Standard
-9-99-9-9(9999) SP171Explosionproof Extension
-9-99-9-9(9999)
Housing material
TYPES & SPECIFICATIONS – SP SERIES EXPLOSIONPROOF
Units: Inch/mm
Approx. 15s
1/2 1/2”G, ”NPT
G1/2"
G1/2"LMax. 7.87(Max. 200)
SPDT Relay 3A@250VAC
1.22(31)
f1.50(f38)
f3.07(f78)
1.81(46)
1.26(32)
f0.291(f7.4)
3.07(78)
f1.50(f38)
f3.07(f78)
1.81(46)
1.26(32)
f0.291(f7.4)
3.07(78)
NEPSI PROOF NO. GYJ12.1521x Ex d IIC T6 Gb
NC C NOF G
5 Pole Terminal Block
5
DIMENSIONS – SP SERIES ALL TYPES
Thread Height
L
1/4”
1/2”
1”
Thread Size / Style PF / BSP
Thread Height L
0.335 (8.5) 0.984 (25)
0.413 (10.5) 1.22 (31)
0.630 (16) 1.417 (36)
Standard Probe
PT / NPT
Thread Height L
0.394 (10) 0.984 (25)
0.75 (19) 1.575 (40)
0.787 (20) 1.575 (40)
1/2”
1”
Thread Size / Style PF / BSP
Thread Height
0.452 (11.5)
0.630 (16)
Extension Probe (L = 7.87”/200mm Max.)
PT / NPT
Thread Height
0.630 (16)
0.787 (20)
SPECIFICATIONS – SP SERIES THREAD CONNECTIONS
Fig. 1
a
a
da³4xd
Fig. 3
Fig. 2
Fig. 4
1. Install the SP series thermal dispersion flow switch using the sealing gasket provided with the unit.2. Refer to Figure 1. The distance “a” must be at least 4 times greater than the pipe diameter the SP
series flow switch is installed in.3. Refer to Figure 2. To ensure proper operation of the SP series flow switch, make certain that the
flow switch probe Is completely immersed in the fluid flow and that the pipeline is free of any entrained air.
4. Refer to Figure 3. If the pipe the SP is installed in will not contain a full pipe flow, install the SP flow switch to the bottom of the pipe (horizontal pipe).
5. For best sensitivity, speed of response and overall operation, install the SP series flow switch in the orientation to the flow stream as show in Figure 4.
6. Installing a filter upstream of the SP flow switch is recommended if the fluid contains impurities as this can increase life by reducing abrasion on the switch probe element.
6
INSTALLATION NOTES – SP SERIES
7
ELECTRICAL CONNECTIONS
13
4
2
ALARMSENSITIVITY
)3
1
4NPN
Fig. 3: NPN output wiring
Brown
Black
Blue
))
Relay
Fig. 5: 5A relay output wiring (SPDT)
Blue
Black
Red
WIRING
White
YellowCOM
NC
NO
)3
1
4PNP
Fig. 4: PNP output wiring
Blue
Black
Brown
))
)1
3
2NO
Blue
Green
Brown
))
4 Black)
3-wire
Fig. 6: 1A relay output wiring (Normally Open)
)1
3
2NC
Blue
Green
Brown
))
4 Black)
Fig. 7: 1A relay output wiring (Normally Closed)
Fig. 1: M12 connector pin designation (NPN, PNP and 1A relay outputs)
Fig. 2: SP flow switch w/ M12 connector (top view)
5-wire
4-wire
Fig. 8: 3A/5A relay output wiring
NC C NOF G
5-terminal
0: 304SS 6: 316SS
L: 316LSS S: Other
N: NPN
P: PNP
A: Relay SPST N.O. (1A@30VDC; 0.3A@125VAC)
B: Relay SPST N.C. (1A@30VDC; 0.3A@125VAC)
C: Relay SPDT N.O./N.C. (5A@250VAC) for SP210, 211 and 212 only
0: Compact1: Stainless steel (for SPDT relay output)2: Economy
Electrical cable length (unit: m)
† If standard length probe is desired, leave this selection blank.* Consult thread dimensions table on page 4 for standard lengths* Customized length is available to 7.87” (200mm) maximum* Length tolerance is ±5mm
Type
SP2 9 9- 9 - 99 - 9- 9 - ( 9999 )
Probe material
Output
Size Specification
A: 3/8" B: 1/2" C: 3/4" D: 1" 2: 1/4"S: Other
Q: PTT: BSPR: PFU: NPTV: GASS: Other
Process connection*
Probe length† (unit: mm)*
2: 6.5ft (2m)
5: 16.4ft (5m)
0: Standard1: Extension2: High temperature (not available for Economy type)
Probe style
*Standard connection size is ½”NPT, ½”PT or ½”PF
ORDER INFORMATION – SP SERIES
8
1: 304SS
2: 316SSL
6: 316SS
C: Relay SPDT N.O./N.C. (3A@250VAC)
70: Explosionproof standard71: Explosionproof extension
Probe length (unit: mm)
† If standard length probe is desired, leave this selection blank.* Consult thread dimensions table on page 4 for standard lengths* Customized length is available to 7.87” (200mm) maximum* Length tolerance is ±5mm
Type
Probe material
Output
Size Specification
B: 1/2” D: 1” S: Other
Q: PTT: BSPR: PFV: GASU: NPTS: Other
Process connection*
ORDER INFORMATION – SP SERIES EXPLOSIONPROOF
9
SP170- 9 - 99 - 9 - 9999( )
*
SECTIONAL DRAWING
1. O-Ring
2. Paddle
3. Axis
4. Reed switch
5. Spring
6. Magnet
7. Housing
8. Process connection
9. Center rod
MODEL: SF1800Standard model
1"1-1/4"
1-1/2"
2"
2-1/2"
3"
2
3 8
49
5
6
1
7
Optional explosionproof* cable gland part
1/2"NPT
The SF series flow switch is capable of detecting the flow of liquids in pipes. It is an electromechanical device, reliable and cost effective. When the liquid is not flowing within the pipe, the spring (item 5 in drawing) is fully extended, pulling the magnet (item 6) downward and opening the reed switch. As flow of the liquid occurs and the paddle is thrusted forward by ³20⁰~30⁰ the paddle will push the magnet upward and actuate the reed switch, thereby closing the circuit. The length of the paddle can be adjusted during installation to best fit the pipe’s diameter.
Fig. 1: Reed switch is “on” (closed) with liquid flowing
spring
magnet
reed switch
axis
paddle
*1/2"NPT
3.15(80)
Fig. 2: Reed switch is “off” (open) with no flow
spring
magnet
reed switch
axis
paddle
MODEL: SF1710Explosion proof model
NEPSI
1"PT
HEX38
0.984(25)
2.76(70)
1"PT
HEX38
0.984(25)
OPERATING PRINCIPLE – SF SERIES
10
PRODUCT INTRODUCTION – SF SERIES
DIMENSIONSUnits: Inch/mm
3.15(80)
0.867(22)
0.512(13)0.867(22)
5.512(140)
3.15(80)
0.867(22)0.512(13)0.867(22)
5.512(140)
1. The paddle length is to be cut during installation. The length should be that which will extend the paddle into the pipe to the lowest point in the pipe for switch activation. Cut the paddle to the appropriate pipe size as marked on the paddle or wherever desired. The minimum is 1” pipe size *
2.The SF flow switch must be installed so that the paddle is at a right angle to the flow of the fluid in the pipe.
3.The SF flow switch must be installed so that the “FLOW” mark on the process connection will be parallel to the pipe.
4.Before installing the unit apply thread sealant and then tighten.
5.Height of mounting coupling on pipe should not exceed 1.25” (32mm) from inside wall of pipe or 0.874” (22.2mm) from outside wall of pipe. **
1. The operating pressure and temperature limits as shown in the SPECIFICATIONS table must not be exceeded. Verify before installation.
2. Large and sudden changes in fluid temperature and density (specific gravity) will influence the flow switching accuracy.
3. Shock and vibration should be minimized in order to ensure long life.
4. Excessive debris within the fluid may inhibit paddle operation. Periodic maintenance should include re-moval, inspection and cleaning if required.
5. Properly sealing the conduit entrance and process connection will minimize or eliminate damage due to moisture.
* smaller sizes or for plastic pipes.** See drawing below.
Minimum pipe size is 1”NPT. Not recommended for
CAUTIONINSTALLATION
FLOW CONTROL RANGE
1"
Activate Deactivate
1-1/2" 2" 2-1/2" 3"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
Paddle Length
Model Specification
Enclosure material/rating
Process temperature
Wetted material
Pressure
Pressure drop
Setpoint tolerance
Repeatability tolerance
Switch rating
Aluminum / Ex d IIC T4~T6
-22⁰F~212⁰F (-30⁰C~100⁰C)
Aluminum / IP65
-22⁰F~302⁰F (-30⁰C~150⁰C)
SF1710 SF1800
*1 gallon = 3.7854 liter
4.7gpm 3.9 10.9 8.3 19.9
31.3 7.7 6.1
5.7 4.5
16.5
13.4
8.4
16.1
12.3
9.5
6.3
25.2
15.1
13.9
22.8
18.5
12.8
10
29.7
20.4
17.1
21.9
15.4
12.8
11
TYPES & SPECIFICATIONS, INSTALLATION – SF SERIES
SPECIFICATIONS
304SS
355psi (24.5bar)
3psi (0.2bar)
±25%
±5%
60W@220VAC/200VDC, SPDT
Pipeline Size
(32Max)
Activate Deactivate Activate Deactivate Activate Deactivate Activate Deactivate
Aplus Finetek Sensor, Inc.
Represented by:
08-SPSF-B0-AP, 03/10/2016