Spray Foam and NRCA
James R. Kirby, AIA
Associate Executive Director, Technical Communications
National Roofing Contractors Association
Spray Foam 2008La Jolla, CA
March 2008
2008 Manual—SPF Highlights
• Hard copy, CD-ROM and on-line
• Hard copy is free with paid 2008 NRCA membership
• CD-ROM contains:
– The NRCA Roofing Manual: Membrane Roof Systems—
2007
– The NRCA Roofing Manual: Metal Panel and SPF Roof
Systems—2008
– The NRCA Roofing and Waterproofing Manual—Fifth
Edition with 2003 and 2006 Updates
2008 Manual—SPF Highlights
• Materials
– Primers, SPF, Protective Surfacings
• Design Considerations
– Applicability and Restrictions, Wind
Resistance, Building and Thermal Movement,
Penetrations and Details, Drainage, Vapor
Retarders and Moisture Control, Fire
Resistance, Building Code Information,
Standards, Roof Decks and Rigid Insulation
2008 Manual—SPF Highlights
• Application
– Job-site Considerations, Delivery and Storage, SPF
and Protective Surfacing Application, QC, Sheet
Metal, Tie-offs and Weather Protection
• Roof System Design Guidelines
– Nailable Deck, Insulation, Overlayment Board,
Concrete Deck, Bituminous Vapor Retarder, BUR,
Mod Bit, Single-ply, Temporary
• Construction Details
– 100 Construction Details—38 are Reroofing Details
Construction Details
and Introduction
• Set up for easy use as submittal package
• Priority of details—SPF 3 vs. SPF 3A
• Cricket and saddle recommendations
• Discussion of edge-metal uplift resistance
• And much more…
NRCA’s SPF TF Members
• Jim Andersen
• Ed Lundin
• Sig Hall
• Mike Lanouette
• Jack Moore
THANK YOU!
The NRCA Roofing Manual Series
• The NRCA Roofing Manual: Membrane Roof
Systems—2007
• The NRCA Roofing Manual: Metal Panel and
SPF Roof Systems—2008
• The NRCA Roofing Manual: Steep-slope Roof
Systems—2009
• The NRCA Roofing Manual: Architectural Sheet
Metal, Moisture Control and Reroofing—2010
The NRCA Roofing Manual:
Membrane Roof Systems—2007
Chapter 1—Roof decks
Chapter 2—Insulation
Chapter 3—Roof membranes
Chapter 4—Surfacings
Chapter 5—Design guidelines
Chapter 6—Construction details
Appendices
The NRCA Roofing Manual:
Metal Panel and SPF Roof
Systems—2008
--Introduction
--Metal Panel Roof Systems
--SPF Roof Systems
--Appendices
The NRCA Roofing Manual:
Steep-slope Roof Systems—2009
--Asphalt Shingles
--Clay and Concrete Tile
--Slate
--Wood Shingles and Shakes
--Synthetics and Metal Shingles
The NRCA Roofing Manual:
Architectural Sheet Metal,
Reroofing and Moisture
Control—2010
--Architectural Sheet Metal
--Reroofing
--Moisture Control
--Glossary
Fifth Edition:
--Published in 2001
--Updated in 2003
--Updated in 2006
Sections still applicable:
--Steep-slope Roofing
--Architectural Sheet Metal
--Reroofing
--Moisture Control
--Glossary
NRCA Construction Details
on CD-Rom (2008)• CD-ROM contains construction details
from:
– The NRCA Roofing Manual: Membrane Roof Systems—2007
– The NRCA Roofing Manual: Metal Panel and SPF Roof Systems—2008
– The NRCA Roofing and Waterproofing Manual—Fifth Edition with 2003 and 2006 Updates
• AutoCAD format (.dwg)
Additional NRCA Documents
• Manual for Inspection and Maintenance of Sprayed
Polyurethane Foam-based Roof Systems: A Guide for
Building Owners (NRCA / SPFD, 1998)
• Quality Control Guidelines for the Application of Sprayed
Polyurethane Foam Roofing (NRCA / SPFA, 2003)
• A Field and Laboratory Assessment of Sprayed
Polyurethane Foam-based Roof Systems (R. Dupuis, 1998)
• Performance of Sprayed Polyurethane Foam Flashings on
CD-ROM (R. Dupuis, 2003)
PCCRS
• Vision: To provide performance criteria that effectively optimizes the service lives of long-term constructed roof systems.
• Defining Principles: Roof system performance criteria developed under PCCRS will include consideration of the following: – design
– materials
– application
– inspection and maintenance
PCCRS
• Purpose: The purpose of PCCRS is to provide building owners and the roofing industry with conservative and dependable criteria for constructed roof systems that achieve cost-effective, long-term performance relative to the specific roof system type.
PCCRS is intended to provide guidance. It is not an approval or certification of individual companies' procedures, products or services, nor is it intended to supplant warranties or other representations or perceptions of roof system service life.
PCCRS
• Methodology:The basis for developing roof system performance
criteria is as follows:
• technically supported performance data
• historical field performance
• recognized industry documents/publications for
design, materials, application, and inspection and
maintenance
PCCRS
• Council provides oversight and
resolution
• Criteria Development Groups (CDG)
developed the specific criteria
• Initial 2 CDGs: BUR and SPF
PCCRS SPF CDG
• Initial meeting – Sept 2004
• Most recent meeting – Oct 2007
• Intended to be a 2-year process, but the
initial CDGs were given much latitude by
the Council
Timetable for public review
Feb. 15-May 15: Public Review Draft 1
May 16-June 30: CDGs resolve comments
July 1-July 30: Public Review Draft 2
Aug. 1-Aug. 30: CDGs resolve comments
Sept. 1-Sept 30: Public Review Draft 3
October: Council resolution
Jan. 2009: Publication
PCCRS SPF CDG Members
• Jim Andersen
• Sig Hall
• John Hatfield
• Don Lenaker
• Ed Lundin
• Jamie McAdam
• Tom Sparks (retired)
• Joe Stockdale (new)
THANK YOU!
NRCA Membership Benefits
• 4200 members
• The Roofing Manual Series (free with annual membership)
• Technical assistance
• Educational material– Customized selection of over 60 products as a new member
• More than 40,000 consumers access www.nrca.net each month
• ―Find a contractor‖ by ―SPF‖
• NRCA SmartBrief E-mail and weekly NRCA E-news
• Special Reports and For Members Only
• Professional Roofing and NRCA Insider
NRCA Membership Benefits
• NRCA logo
• Access to affinity partners– American Express Open card
– Firestone AutoCare
– Shell fuel card … and more.
• Your member dues go towards– Training programs
– Washington DC representation … and more.
• Up to 50% off retail prices for bookstore purchases
• Over 20,000 copies of 5th Edition Manual in circulation, includes SPF section
• Stop by the NRCA booth for more information
Also…
• Center for Environmental Innovations in
Roofing
• NRCA University – online education,
customized training (OSHA 10-hour class)
and accreditation (CEU)
• Future Executive Institute
• roofwinddesigner.com
• energywise.specright.net