5
TITLE SHEET T-1 DWG NO. DRAWING INDEX DESCRIPTION THAT PORTION OF THE NORTH HALF OF GOVERNMENT LOT 7 OF SECTION 2, TOWNSHIP 24 NORTH, RANGE 43 EAST OF THE WILLAMETTE MERIDIAN, LYING WESTERLY OF GLENROSE ROAD; EXCEPT THE NORTH 318 FEET THEREOF; SITUATE IN THE COUNTY OF SPOKANE, STATE OF WASHINGTON. LEGAL DESCRIPTION APPROVED BY CONSTRUCTION MANAGER DATE SIGNATURE PROJECT MANAGER SITE ACQUISITION ZONING APPROVAL / SIGN OFF PROJECT CONTACT LIST PROJECT INFORMATION UTILITY COMPANIES 4620 S GLENROSE ROAD SPOKANE, WA 99223 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. PROPRIETARY INFORMATION RF LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 FAX: (425) 482-2893 PROJECT ARCHITECT: APPLICANT: 5005 E 46TH AVENUE SPOKANE, WA 99223 CONTACT: RICH & JACI FINK PHONE: (509) 448-0343 PROPERTY OWNER: REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. SCALE DISCLAIMER FROM VERIZON WIRELESS OFFICE: GET ON I-90 E FROM SE EASTGATE WAY. FOLLOW I-90 E TO E 3RD AVE IN SPOKANE. TAKE EXIT 283B FROM I-90 E. CONTINUE ON E 3RD AVE. TAKE S CARNAHAN RD TO S GLENROSE RD MERGE ONTO E 3RD AVE TURN RIGHT ONTO S HAVANA ST TURN LEFT ONTO E 8TH AVE TURN RIGHT ONTO S CARNAHAN RD TURN LEFT ONTO S GLENROSE RD TAKE THE 2ND RIGHT TO STAY ON S GLENROSE RD DESTINATION WILL BE ON THE RIGHT DRIVING DIRECTIONS T-1 TITLE SHEET C-1 CIVIL SURVEY A-3 ELEVATIONS A-1 SITE PLAN A-2 ENLARGED SITE PLAN PROJECT CONSULTANT: PROLAND, LLC 2607 S SOUTHEAST BLVD, B-214 SPOKANE, WA 99223 CONTACT: MEG DEMAND PHONE: (509) 710-3606 SPO MORAN VERIZON WIRELESS 3245 158TH AVENUE SE, MS231 BELLEVUE, WA 98008 VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF 60'-0" MONOPINE WITH (12) PANEL ANTENNAS, AND 7'-9"X22'-0" EQUIPMENT PAD WITHIN A 40'x60' FENCED LEASE AREA. CENTURY LINK PHONE: (800) 777-9594 TELEPHONE: AVISTA UTILITIES PHONE: (800) 227-9187 POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: POWER: ZONING CLASSIFICATION: CODE INFORMATION: URBAN RESERVE BUILDING CODE: IBC 2012 CONSTRUCTION TYPE: IIB OCCUPANCY: U, S-2 JURISDICTION: SPOKANE COUNTY PROPOSED BUILDING USE: UNMANNED TELECOM LATITUDE: SITE LOCATION (NAD83): 47° 36' 39.50" N LONGITUDE: 117° 20' 02.01" W TOP OF STRUCTURE: 2440.23' AMSL BASE OF STRUCTURE: 2380.23' AMSL 2400 SF PROJECT LEASE AREA: 34021.9081 PARCEL NUMBER: 8.17 ACRES AREA OF PARCEL: 2400 SF NEW IMPERVIOUS AREA: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS UNAFFECTED. GENERAL INFORMATION: PROJECT DESCRIPTION: 60'-0" AGL 0'-0" AGL (47.610972° N) (117.333892° W) VICINITY MAP NOT TO SCALE GENERAL LOCATION MAP NOT TO SCALE PROJECT PROJECT SHEET NUMBER REVISIONS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BY DATE SHEET TITLE REV Structural Engineering Architectural www.LDCcorp.com 14201 NE 200th St., #100 Woodinville, WA 98072 Fx. 425.482.2893 Ph. 425.806.1869 Survey SPO MORAN 4620 S GLENROSE ROAD SPOKANE, WA 99223 3-11-14 AT RBH 1 3-11-14 PRELIMINARY ZONING RBH 2 3-26-14 REVISED PRELIMINARY ZONING RBH 3 4-8-14 REVISED PRELIMINARY ZONING RBH 4 4-18-14 REVISED PRELIMINARY ZONING RBH 5 6-30-14 REVISED PRELIMINARY ZONING RBH 8828 PROJECT MANAGER: PROLAND, LLC 2607 S SOUTHEAST BLVD, B-214 SPOKANE, WA 99223 CONTACT: MEG DEMAND PHONE: (509) 710-3606 LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT: VANCE BLUE, PLS PHONE: (425) 806-1869 FAX: (425) 482-2893 PROJECT SURVEYOR:

Transcript of SPO Moran-RPZD_20140701 - … · 01/07/2014 · code information: urban reserve ... contact: vance...

TITLE SHEET

T-1

DWG NO.DRAWING INDEX

DESCRIPTION

THAT PORTION OF THE NORTH HALF OF GOVERNMENT LOT 7OF SECTION 2, TOWNSHIP 24 NORTH, RANGE 43 EAST OFTHE WILLAMETTE MERIDIAN, LYING WESTERLY OFGLENROSE ROAD;EXCEPT THE NORTH 318 FEET THEREOF;SITUATE IN THE COUNTY OF SPOKANE, STATE OFWASHINGTON.

LEGAL DESCRIPTION

APPROVED BY

CONSTRUCTION MANAGER

DATE SIGNATURE

PROJECT MANAGER

SITE ACQUISITION

ZONING

APPROVAL / SIGN OFF

PROJECT CONTACT LIST

PROJECT INFORMATION UTILITY COMPANIES

4620 S GLENROSE ROADSPOKANE, WA 99223

THE INFORMATION CONTAINED IN THIS SET OFCONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE OTHER THAN THAT WHICHRELATES TO VERIZON WIRELESS SERVICES IS STRICTLYPROHIBITED.

PROPRIETARY INFORMATION

RF

LDC, INC.14201 NE 200TH ST, SUITE 100WOODINVILLE, WA 98072CONTACT: RICHARD B. HALL, AIAPHONE: (425) 806-1869FAX: (425) 482-2893

PROJECT ARCHITECT:

APPLICANT:5005 E 46TH AVENUESPOKANE, WA 99223CONTACT: RICH & JACI FINKPHONE: (509) 448-0343

PROPERTY OWNER:

REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TOEACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED

DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFYALL DIMENSIONS AND ADVISE CONSULTANTS OF ANYERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THISDRAWINGS ARE SUPERSEDED BY THE LATEST REVISION.

SCALE DISCLAIMER

FROM VERIZON WIRELESS OFFICE:

GET ON I-90 E FROM SE EASTGATE WAY.FOLLOW I-90 E TO E 3RD AVE IN SPOKANE.TAKE EXIT 283B FROM I-90 E.CONTINUE ON E 3RD AVE.TAKE S CARNAHAN RD TO S GLENROSE RDMERGE ONTO E 3RD AVETURN RIGHT ONTO S HAVANA STTURN LEFT ONTO E 8TH AVETURN RIGHT ONTO S CARNAHAN RDTURN LEFT ONTO S GLENROSE RDTAKE THE 2ND RIGHT TO STAY ON S GLENROSE RDDESTINATION WILL BE ON THE RIGHT

DRIVING DIRECTIONS

T-1 TITLE SHEETC-1 CIVIL SURVEY

A-3 ELEVATIONS

A-1 SITE PLANA-2 ENLARGED SITE PLAN

PROJECT CONSULTANT:PROLAND, LLC2607 S SOUTHEAST BLVD, B-214SPOKANE, WA 99223CONTACT: MEG DEMANDPHONE: (509) 710-3606

SPO MORAN

VERIZON WIRELESS3245 158TH AVENUE SE, MS231BELLEVUE, WA 98008

VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNEDTELECOMMUNICATIONS FACILITY CONSISTING OF 60'-0" MONOPINEWITH (12) PANEL ANTENNAS, AND 7'-9"X22'-0" EQUIPMENT PADWITHIN A 40'x60' FENCED LEASE AREA.

CENTURY LINKPHONE: (800) 777-9594

TELEPHONE:AVISTA UTILITIESPHONE: (800) 227-9187

POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:POWER:ZONING CLASSIFICATION:CODE INFORMATION:

URBAN RESERVEBUILDING CODE: IBC 2012CONSTRUCTION TYPE: IIBOCCUPANCY: U, S-2JURISDICTION: SPOKANE COUNTYPROPOSED BUILDING USE: UNMANNED TELECOM

LATITUDE:SITE LOCATION (NAD83):

47° 36' 39.50" NLONGITUDE: 117° 20' 02.01" WTOP OF STRUCTURE: 2440.23' AMSLBASE OF STRUCTURE: 2380.23' AMSL

2400 SFPROJECT LEASE AREA:

34021.9081PARCEL NUMBER:

8.17 ACRESAREA OF PARCEL:

2400 SFNEW IMPERVIOUS AREA:

1. PARKING REQUIREMENTS ARE UNCHANGED.2. TRAFFIC IS UNAFFECTED.3. SIGNAGE IS UNAFFECTED.

GENERAL INFORMATION:

PROJECT DESCRIPTION:

60'-0" AGL0'-0" AGL

(47.610972° N)(117.333892° W)

VICINITY MAPNOT TO SCALE

GENERAL LOCATION MAPNOT TO SCALE

PROJECT

PROJECT

SHEET NUMBER

REVISIONS

DATE:DRAWN BY:

CHECKED BY:

SITE

DESCRIPTION BYDATE

SHEET TITLE

REV

StructuralEngineering

Architectural

www.LDCcorp.com

14201 NE 200th St., #100Woodinville, WA 98072 Fx. 425.482.2893

Ph. 425.806.1869

Survey

SPO MORAN

4620 S GLENROSE ROADSPOKANE, WA 99223

3-11-14AT

RBH

1 3-11-14 PRELIMINARY ZONING RBH

2 3-26-14 REVISED PRELIMINARY ZONING RBH

3 4-8-14 REVISED PRELIMINARY ZONING RBH

4 4-18-14 REVISED PRELIMINARY ZONING RBH

5 6-30-14 REVISED PRELIMINARY ZONING RBH

8828

PROJECT MANAGER:PROLAND, LLC2607 S SOUTHEAST BLVD, B-214SPOKANE, WA 99223CONTACT: MEG DEMANDPHONE: (509) 710-3606

LDC, INC.14201 NE 200TH ST, SUITE 100WOODINVILLE, WA 98072CONTACT: VANCE BLUE, PLSPHONE: (425) 806-1869FAX: (425) 482-2893

PROJECT SURVEYOR:

CIVIL SURVEY

C-1SHEET NUMBER

REVISIONS

DATE:DRAWN BY:

CHECKED BY:

SITE

DESCRIPTION BYDATE

SHEET TITLE

REV

ResidentialInfrastructure

Commercial

www.LDCcorp.com

14201 NE 200th St., #100Woodinville, WA 98072 Fx. 425.482.2893

Ph. 425.806.1869

Telecom

SPOMORAN

4620 S GLENROSE RDSPOKANE, WA

3-11-14IGM

VVB

PROJECT

PROPOSED VERIZON WIRELESS 20'ACCESS & UTILITY EASEMENT

SITE PLAN

A-1SITE PLAN 122"x34" SCALE: 1" = 50' 11"x17" SCALE: 1" = 100'

1

EXISTING SITE ACCESS

SHEET NUMBER

REVISIONS

DATE:DRAWN BY:

CHECKED BY:

SITE

DESCRIPTION BYDATE

SHEET TITLE

REV

StructuralEngineering

Architectural

www.LDCcorp.com

14201 NE 200th St., #100Woodinville, WA 98072 Fx. 425.482.2893

Ph. 425.806.1869

Survey

SPO MORAN

4620 S GLENROSE ROADSPOKANE, WA 99223

3-11-14AT

RBH

1 3-11-14 PRELIMINARY ZONING RBH

2 3-26-14 REVISED PRELIMINARY ZONING RBH

3 4-8-14 REVISED PRELIMINARY ZONING RBH

4 4-18-14 REVISED PRELIMINARY ZONING RBH

5 6-30-14 REVISED PRELIMINARY ZONING RBH

8828

PROPOSED VERIZON WIRELESS ANTENNAMOUNTED ON 60'-0" MONOPINE

30 3'TO

WER

SET BA

CK

462'

TOWER SETBACK

40' TOWERSETBACK

PROPOSED VERIZON WIRELESS 20'ACCESS & UTILITY EASEMENT

PROPOSED VERIZON WIRELESSEQUIPMENT PAD WITHIN A40'x60' FENCED LEASE AREA

PROPOSED 12'-0" GRAVELACCESS ROAD

R20'

ENLARGED SITE PLAN 122"x34" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"

ENLARGED SITE PLAN

A-2

1A-3

SECTOR C : 260°

SEC

TOR

A:0°

SECTOR B : 60°

SHEET NUMBER

REVISIONS

DATE:DRAWN BY:

CHECKED BY:

SITE

DESCRIPTION BYDATE

SHEET TITLE

REV

StructuralEngineering

Architectural

www.LDCcorp.com

14201 NE 200th St., #100Woodinville, WA 98072 Fx. 425.482.2893

Ph. 425.806.1869

Survey

SPO MORAN

4620 S GLENROSE ROADSPOKANE, WA 99223

3-11-14AT

RBH

1 3-11-14 PRELIMINARY ZONING RBH

2 3-26-14 REVISED PRELIMINARY ZONING RBH

3 4-8-14 REVISED PRELIMINARY ZONING RBH

4 4-18-14 REVISED PRELIMINARY ZONING RBH

5 6-30-14 REVISED PRELIMINARY ZONING RBH

8828

PROPOSED VERIZON WIRELESS RAYCAP OVP DISTRIBUTION MOUNTED TOPROPOSED ICE BRIDGE LEG NEAR CABINETS.

PROPOSED VERIZON WIRELESS EQUIPMENT CONCRETE PAD (7'-9"x22'-0").

PROPOSED VERIZON WIRELESS GPS ANTENNA MOUNTED TO ICE BRIDGE LEG.

PROPOSED VERIZON WIRELESS RRUS UNIT MOUNTED ON RING MOUNT (TYP 1PER AWS & PCS ANTENNAS - 6 TOTAL).

PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTEDTO MONOPOLE.

PROPOSED 60'-0" MONOPINE. ENGINEERED BY OTHERS. SEE SITE NOTE NO. 2.

PROPOSED VERIZON WIRELESS 50 KW GENERATOR MOUNTED ONA CONCRETE PAD.

PROPOSED VERIZON WIRELESS BBU CABINET.

PROPOSED VERIZON WIRELESS POWER CABINET.

PROPOSED VERIZON WIRELESS RING MOUNT.

PROPOSED VERIZON WIRELESS MOD CELL CABINET.

PROPOSED VERIZON WIRELESS LTE CABINET.

1. VERIFY ANTENNA MODEL, RAD CENTER & AZIMUTHS WITH LOCKDOWNSET RF SITE BUILD FORM.

2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY OTHERS& STAMPED BY A LICENSED STRUCTURAL ENGINEER. IN ADDITION TOTHE PROPOSED ANTENNA LOADING THE TOWER SHALL BE DESIGNED TOCARRY AT LEAST ONE ADDITIONAL WIRELESS CARRIER ANTENNA ARRAY.

PROPOSED VERIZON WIRELESS TMA (TOWER MOUNTED AMPLIFIER) MOUNTEDTO ANTENNA MOUNT (1 PER SECTOR, 3 TOTAL).

SITE NOTES

GENERAL NOTES1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES,

REGULATIONS AND SAFETY REGULATIONS. ALL OSHA REGULATIONS, ALL PUBLIC ANDMUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS ANDDIRECTIVES.

2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OFWORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THECONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY ANDALL DISCREPANCIES TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS INTHE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROMCOMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENTOF THESE DOCUMENTS.

3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OFCABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING.

4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA,COAX AND ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS.

5. ANTENNA AZIMUTHS SHOWN ON THESE DRAWINGS ARE BASED ON TRUE NORTH. ALLAZIMUTHS MUST BE VERIFIED WITH THE CORRECT SMR PRIOR TO CONSTRUCTION.

PROPOSED UNDERGROUND POWER & TELCO ROUTING.

PROPOSED 6'-0" HIGH CHAIN LINK FENCE WITH BROWN OBSCURING PRIVACYSLATS.

PROPOSED 12'-0" WIDE CHAIN LINK DOUBLE SWING GATE WITH LOCKING MECHANISM& BROWN OBSCURING PRIVACY SLATS. VZW SIGNAGE MOUNTED TO GATE.

PROPOSED COAXIAL CABLE / FIBER TO ANTENNAS.

PROPOSED 10'-0" HIGH PEDESTAL MOUNTED ICE BRIDGE WITH 8'-0" CLEARBELOW COAX SUPPORT.

PROPOSED T-ARM ANTENNA MOUNT.

PROPOSED VERIZON WIRELESS PANEL ANTENNA (4 PER SECTOR, 12 TOTAL).

SITE TO BE FILLED WITH 6" OF 3/4"Ø CRUSHED ROCK W/ WEED BARRIER ON95% COMPACTED FILL.

PROPOSED VERIZON WIRELESS LEASE AREA (40'X60').1

2

3

4

5

6

7

8

9

10

12

13

14

15

19

20

21

23

PROPOSED UTILITY H-FRAME.25

27

CONSTRUCTION PLAN KEYED NOTES

28

29

30

PR

OPO

SED

VER

IZO

NW

IRE

LESS

22'-0

"EQ

UIP

MEN

TPA

D2

8

40'-0

"SE

TBAC

KTO

PR

OPE

RTY

LIN

E

EXISTING BUILDING(TO REMAIN)

20'-0"P

RO

POSE

DVE

RIZ

ON

WIR

ELE

SS60

'-0"F

EN

CED

LEA

SEAR

EA

PROPOSED VERIZON WIRELESS 40'-0" FENCED LEASE AREA

PROPOSED VERIZONWIRELESS 12'-0"

WIDE ACCESS GATE& GRAVEL ACCESS

ROAD

14'-0"14'-0"

1'-0"

24 '-10"

3'-0"

3'-0

"

8'-0"

3'-6

"

PROPOSEDVERIZON WIRELESS

7'-9" EQUIPMENT PAD

10

30

30

29

29

28

27

(FUT)

(FUT)

19

1 9

23

25

12

157

25

21

6

144

13

3

19

20

2

5

PROPOSED VERIZON WIRELESS20'-0" ACCESS & UTILITY EASEMENT

8'-2

"4'

-0"

3'-4"

3'-2"

3'-6"

11'-5

"P

RO

PER

TYSE

TBAC

K

ELEVATION

A-3PROPOSED NORTH ELEVATION (LOOKING SOUTH)22"x34" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = 1'-0"

2SHEET NUMBER

REVISIONS

DATE:DRAWN BY:

CHECKED BY:

SITE

DESCRIPTION BYDATE

SHEET TITLE

REV

StructuralEngineering

Architectural

www.LDCcorp.com

14201 NE 200th St., #100Woodinville, WA 98072 Fx. 425.482.2893

Ph. 425.806.1869

Survey

SPO MORAN

4620 S GLENROSE ROADSPOKANE, WA 99223

3-11-14AT

RBH

1 3-11-14 PRELIMINARY ZONING RBH

2 3-26-14 REVISED PRELIMINARY ZONING RBH

3 4-8-14 REVISED PRELIMINARY ZONING RBH

4 4-18-14 REVISED PRELIMINARY ZONING RBH

5 6-30-14 REVISED PRELIMINARY ZONING RBH

8828

PROPOSED VERIZON WIRELESS RAYCAP OVP DISTRIBUTION MOUNTED TOPROPOSED ICE BRIDGE LEG NEAR CABINETS.

PROPOSED VERIZON WIRELESS EQUIPMENT CONCRETE PAD (7'-9"x22'-0").

PROPOSED VERIZON WIRELESS GPS ANTENNA MOUNTED TO ICE BRIDGE LEG.

PROPOSED VERIZON WIRELESS RRUS UNIT MOUNTED ON RING MOUNT (TYP 1PER AWS & PCS ANTENNAS - 6 TOTAL).

PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX MOUNTEDTO MONOPOLE.

PROPOSED 60'-0" MONOPINE. ENGINEERED BY OTHERS. SEE SITE NOTE NO. 2.

PROPOSED VERIZON WIRELESS 50 KW GENERATOR MOUNTED ONA CONCRETE PAD.

PROPOSED VERIZON WIRELESS POWER CABINET.

PROPOSED VERIZON WIRELESS RING MOUNT.

PROPOSED VERIZON WIRELESS MOD CELL CABINET.

PROPOSED VERIZON WIRELESS LTE CABINET.

1. VERIFY ANTENNA MODEL, RAD CENTER & AZIMUTHS WITH LOCKDOWNSET RF SITE BUILD FORM.

2. ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY OTHERS& STAMPED BY A LICENSED STRUCTURAL ENGINEER. IN ADDITION TOTHE PROPOSED ANTENNA LOADING THE TOWER SHALL BE DESIGNED TOCARRY AT LEAST ONE ADDITIONAL WIRELESS CARRIER ANTENNA ARRAY.

PROPOSED VERIZON WIRELESS TMA (TOWER MOUNTED AMPLIFIER) MOUNTEDTO ANTENNA MOUNT (1 PER SECTOR, 3 TOTAL).

SITE NOTES

GENERAL NOTES1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES,

REGULATIONS AND SAFETY REGULATIONS. ALL OSHA REGULATIONS, ALL PUBLIC ANDMUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANIES' REGULATIONS ANDDIRECTIVES.

2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OFWORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THECONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY ANDALL DISCREPANCIES TO REPRESENTATIVE. ANY MINOR ERRORS AND OMISSIONS INTHE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROMCOMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENTOF THESE DOCUMENTS.

3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OFCABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING.

4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA,COAX AND ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS.

5. ANTENNA AZIMUTHS SHOWN ON THESE DRAWINGS ARE BASED ON TRUE NORTH. ALLAZIMUTHS MUST BE VERIFIED WITH THE CORRECT SMR PRIOR TO CONSTRUCTION.

PROPOSED 6'-0" HIGH CHAIN LINK FENCE WITH BROWN OBSCURING PRIVACYSLATS.

PROPOSED 12'-0" WIDE CHAIN LINK DOUBLE SWING GATE WITH LOCKING MECHANISM& BROWN OBSCURING PRIVACY SLATS. VZW SIGNAGE MOUNTED TO GATE.

PROPOSED COAXIAL CABLE / FIBER TO ANTENNAS.

PROPOSED 10'-0" HIGH PEDESTAL MOUNTED ICE BRIDGE WITH 8'-0" CLEARBELOW COAX SUPPORT.

PROPOSED T-ARM ANTENNA MOUNT.

PROPOSED VERIZON WIRELESS PANEL ANTENNA (4 PER SECTOR, 12 TOTAL).

2

3

4

5

6

7

9

10

12

13

14

15

19

20

23

PROPOSED UTILITY H-FRAME.25

CONSTRUCTION PLAN KEYED NOTES

28

29

30

PROPOSED VERIZON WIRELESS 40'-0" FENCED LEASE AREA9

10

4

7

12

3

1520

TOP OF PROPOSED MONOPINE60'-0" AGL

TIP HEIGHT OF PROPOSEDVERIZON WIRELESS ANTENNAS55'-0" AGL

FINISH GRADE0'-0" AGL

14

EXISTING BUILDING(TO REMAIN)

5

13

6

PROPOSED VERIZONWIRELESS

7'-9" EQUIPMENT PAD

2

19

30

252325

28

29