split casing FIRE PUMP nfpa 2versapump.com/category-product-pump/fire_pump/1.fire1.pdf · The V...
Transcript of split casing FIRE PUMP nfpa 2versapump.com/category-product-pump/fire_pump/1.fire1.pdf · The V...
NFPA 20 std
The V Series Fire Pump is designed toprovide water to stand pipe, sprinkler,chemical mitigation, and hydrant systemsfor fire suppression in industrial andcommercial facilities.
FIRE PUMPSSplit Casing Centrifugal Fire Pump
uLR
LISTED
uLR
LISTED ISO 9001-2008
Features
• Available in capacities up to 5000 GPM(1135 m /hr).
• Pressures up to 400 PSI (270m).• In compliance with NFPA 20 std• Performance and hydrostatic tests.• Dynamic balance impellers.• Space saving design.• Easy maintenance and upkeep.• Available in electric or diesel engine driven
models.• Standard construction: cast iron, bronze
fitted.• Clockwise or counterclockwise rotation is
available to simplify pump room layout.• Packed stuff box.• Grease lubrication.• Available in 50 or 60 cycle.• Suction and discharge flanges are on a
common centerline.
3
2
Split Casing Centrifugal Fire Pump
FIRE PUMPS
uLR
LISTED ISO 9001-2008
Fire ProtectionYou have decided to reduce the risk of fre damage
to your facility by installing a UL, ULC listed and/or
FM approved fre pump system. Your next decision
is which system to purchase.
You want a fire pump that is proven in thousands of
installations worldwide. Manufactured by an industry
leader with vast experience in the fire protection field.
You want complete service, from engineering assis-
tance to field start-up. You want a VERSA Pump.
Fire Pump Units & Packaged Systems
Electric Motor Drive and Diesel Engine Drive fire pumps can be furnished for any
combination of pumps, drives, controls and accessories for listed and approved and
non-listed fire service applications. Packaged units and systems lower fire pump
installation costs and offer these advantages:
· Pump, driver, and controller are mounted on a common base.
· Common baseplate unit eliminates the need for separate mounting surfaces.
· Common unit minimizes the need for interconnecting wiring and assembly.
· Equipment arrives in a consolidated shipment, allowing faster and simplifed
installation and handling.
· Custom designed system,
including accessories,
fttings, and layouts
available to meet the
customer’s specifcations.
· In-house
engineering
and design
expertise to
ensure design
requirements are realized.
Housed Fire Pump Packaged Systems
VERSA Pump houses are designed and manufactured to high standards of quality
in materials, construction, and workmanship. VERSA Pump houses are constructed
in accordance with the requirements of UL, ULC, FM, NFPA13, NFPA20, and MBMA.
All housed fre pump packaged systems offer the following advantages:
· Complete unit responsibility
· State of the art engineering designs
· Worldwide technical and
commercial support
· Reduced unit installation cost
· Value-added service for customer
· Single source supplier
Diesel Engine
Packaged System
Electric Motor
Drive Unit
Diesel Engine
Drive Unit
3
uLR
LISTED ISO 9001-2008
With years of experience in fire protection
industry, VERSA can supply fire pump
systems with all necessary accessories ready
for site installation.
GUARANTEED ADVANTAGES
f Simplifies piping designf Single source unit responsibilityf A complete package that will meet
NFPA-20 requirements
FIRE PUMP - ELECTRIC DRIVEN
1. Pump/motor
2. Fire pump controller
(with optional transfer switch)
3. Suction and discharge gauges
4. Air release valve
5. Casing relief valve (not shown)
6. Jockey pump
7. Common base
FIRE PUMP - DIESEL ENGINE DRIVEN
1. Pump/engine assembled with
f Cooling system
f Fuel system
f Battery system
f Exhaust system
2. Fire pump controller
3. Suction and discharge gauges
4. Air release valve
6. Jockey pump
7. Common base
ACCESSORIES - ADDITIONAL (ELECTRIC OR DIESEL)
8. Suction OS&Y gate valve
9. Discharge butterfly valve
10. Check valve
11. Test tee
ACCESSORIES - SPECIAL FOR DIESEL OR VFD
12. Main relief valve
13. Enclosed cone (not shown)
Features common to electric and diesel
Accessories - (electric or diesel)
Accessories - special for diesel or VFD
Fire Pumps & Packaged Systems
HorizontalFire
Systems
4
uLR
LISTED ISO 9001-2008
Fire Pump Accessories - Split Case Pump
Diesel Engine
Fuel Tank
Discharge
Gauge
Casing Relief
Valve
Automatic Air
Release Valve
Compound Type
Suction Gauge
Gauge
Protector
Elbow
Valve
Building Wall
Hose Valve
Hose Valve
Cap & Chain
Outside Hose
Valve Head
(no. of hose
valves is variable)
Flow Meter
Valve
Valve
Valve
Drain
Valve
Test Line Pipe
& Fittings
Nipple
Relief Valve
Enclosed Cone
(anged)
TO WASTE
(with back pressure)
Commercial
Tee
Check
Valve
Concentric Discharge
Increaser (when discharge
tee not used)
Pipe Tee
& ElbowHorizontal Electric Motor
Eccentric
Suction ReducerValve
FROM
WATER
SUPPLY
TO WASTE
TO WASTE
TO HOSE
TO WASTE
OR SUPPLY
TO SYSTEM
Valve
Building Wall
Hose Valve
Hose Valve
Cap & Chain
Outside Hose
Valve Head
(no. of hose
valves is variable)
Flow Meter
Valve
Valve
Valve
Drain
Valve
Test Line Pipe
& Fittings
Nipple
Relief Valve
Enclosed Cone
(anged)
TO WASTE
(with back pressure)
Commercial
Tee
Check
Valve
Concentric Discharge
Increaser (when discharge
tee not used)Pipe Tee
& Elbow
TO WASTE
TO HOSE
TO WASTE
OR SUPPLY
TO SYSTEM
Automatic Air
Release Valve Fittings
& Flange For Engine
Diesel
Engine
Right
Angle Gear
Column
Water Level
Testing Device
(extend to strainer
in well installations)
Basket Strainer
(sump installation)
Discharge
Assembly
Tap For Automatic
Air Release Valve
For Motor Drive
Bowl Assembly
Cone Strainer
(well installation)
Vertical
Electric
Motor
Fuel Tank
FROM WATER
SUPPLY
Discharge
Gauge
5
NFPA 20 Std Fire Pump
Fire Pump Accessories - Vertical Turbine Pump
uLR