Spectra Optia®
Mononuclear Cell (MNC)Collection
Theo Bannink
![Page 2: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/2.jpg)
WHY A NEW PLATFORM?
The Cobe Spectra is used in more than 100.000 MNC collections each year.
Cobe Spectra is available with two programs MNC and AutoPBSC
Spectra Optia has been designed to replace the current Cobe Spectra apheresis system with the latest technology.
The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s MNC procedure with the relatively higher purity levels associated with the AutoPBSC procedure. And at the same time adding consistency trought automation.
![Page 3: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/3.jpg)
Spectra Optia Summer 2002
![Page 4: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/4.jpg)
Spectra Optia January 2003
![Page 5: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/5.jpg)
Spectra Optia
April 2007: CE-marked for Therapeutic Plasma Exchange (Optia TPE)
August 2007 : FDA approval for TPE in the US
Today: TPE is sold in more than 40 countries all over the world.
Optia TPE is fast, easy and safe.
January 2008: CE –marked for White Blood Cell Collection (Optia MNC), and September start MNC clinical trial in Europe
![Page 6: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/6.jpg)
Emerging Markets EMEA
Team Ready 2009!
ECV = 191 ml
![Page 7: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/7.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 8: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/8.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 9: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/9.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 10: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/10.jpg)
Buffycoat
![Page 11: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/11.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 12: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/12.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 13: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/13.jpg)
Emerging Markets EMEA
Team Ready 2009!
![Page 14: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/14.jpg)
Optia MNC studyProcedure data summary
![Page 15: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/15.jpg)
What are the communicated core needs?
Top Customer needs• Versatility – MNC is the second (of many) protocols• Flexibility – Operator control, variety of patients• Automate to eliminate errors- identifies and corrects
process variations• Ease of Use • Cell Viability/Functionality – Do the cells engraft?• Performance – Cells in the Bag, Efficiency, Purity
![Page 16: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/16.jpg)
Validation Metrics
Collection efficiency and yield
Purity
Viability of the CD34+ cells and engraftment
System Performance in Patient Environment
Final product volume.
Operator Usability / Trainability
![Page 17: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/17.jpg)
EUT 4 Data
• N=15 runs• Patients from three sites from 09.09.08 – 02.10.08• Diagnosis included
• Multiple Myeloma• Non-Hodgkin’s Lymphoma• Burkitt’s Lymphoma• Hodgkin’s Disease
![Page 18: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/18.jpg)
Patient data - Median (Range)
• Body weight 74kg (45 – 105)• TBV 4500mL (3024 – 5854)• Blood processed 11406mL (5466 – 15752)• Pre WBC. 9.7 x106/mL (3.3 – 55.8)• Pre PLT 93 x106/mL (21 – 234)• Pre CD34+ 73/uL (15 – 314)• TBV Processed 2.30 (1.39 – 4.18)
![Page 19: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/19.jpg)
MNC Data Summary Sheet
![Page 20: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/20.jpg)
CD34+ Collection Efficiency
![Page 21: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/21.jpg)
Product CD34+ Dose/kg
![Page 22: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/22.jpg)
Procedure Time
![Page 23: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/23.jpg)
Final Product Volume
![Page 24: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/24.jpg)
Platelet Collection Efficiency
![Page 25: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/25.jpg)
RBC Residuals
![Page 26: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/26.jpg)
Mobilized Donor Data summary
• Preliminary performance from initial feasibility study performed on mobilized donors• Data updated since presentation at EBMT (March 2008) and ASFA (April 2008)• Donors mobilized using 10mcg/kg GCSF x 3 days
![Page 27: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/27.jpg)
“ The MNC protocol brings the value of efficiency, purity, and consistency to cell collections -ultimately benefiting patients, clinicians and laboratory processes.”
Spectra Optia
![Page 28: Spectra Optia Mononuclear Cell (MNC) Collection 3... · · 2009-02-24The Spectra Optia MNC protocol combines the relative higher Collection Efficiency (%CE) found on Cobe Spectra’s](https://reader030.fdocuments.net/reader030/viewer/2022012923/5b0a825d7f8b9ae61b8c34a8/html5/thumbnails/28.jpg)
Thank you.We welcome you in our booth for more information.