Specificati o n - EMtest · 2012-08-13 · CDN - M4-N CDN for 4 AC power lines L1,L2,L3 and N, max....
Transcript of Specificati o n - EMtest · 2012-08-13 · CDN - M4-N CDN for 4 AC power lines L1,L2,L3 and N, max....
EM TEST AG Tel: +41 (0)61 717 91 91Sternenhofstr. 15 Fax: +41 (0)61 717 91 99CH-4153 Reinach email: [email protected] URL http://www.emtest.com
CDN’s and Clamps
Immunity test to conducted disturbances, induced by radio-frequency fieldsas per IEC 61000-4-6 introduce different types of coupling/decouplingnetworks and clamps according to the characteristics of the interconnec-tion lines. A vast range of appropriate coupling/decoupling networks andclamps as well as the necessary accessories for standard compliant cali-bration are avialable.Apart from the listed standard coupling/decoupling networks EM TESTalso supply special or customised coupling/decoupling networks.
S p e c i f i c a t i o n
• IEC 61000-4-6
and related standards
emc t e s t e qu i pmen t
EM TEST AG Tel: +41 (0)61 717 91 91Sternenhofstr. 15 Fax: +41 (0)61 717 91 99 CDN_Clampv101.docCH-4153 Reinach email: [email protected] 11.10.02Switzerland URL http://www.emtest.com Page 2/2
CDN’s and Clamps
Coupling/decoupling networks as reuired by IEC 61000-4-6, f = 150kHz ... 230MHz
AC power supply lines
CDN - M1 CDN for 1 single AC power line, max. 240V - In = 32 A**CDN - M2/32A CDN for 2 AC power lines L and N, max. 240V In = 32 A**CDN - M3/32A CDN for 3 AC power lines L, N and PE, In = 32 ACDN – M2/M3 CDN for 2 or 3 AC power lines L, N and PE, max. 240V In = 16 ACDN - M4-N CDN for 4 AC power lines L1,L2,L3 and N, max. 3x400V In = 16 ACDN - M4-PE CDN for 4 AC power lines L1,L2,L3 and PE, max. 3x400V In = 16 A**CDN - M4-N/32 CDN for 4 AC power lines L1,L2,L3 and N, In = 32 A**CDN - M4-PE/32 CDN for 4 AC power lines L1,L2,L3 and PE, In = 32 ACDN - M5 CDN for 5 AC power lines L1,L2,L3,N and PE, max. 3x400V In = 16 A**CDN - M5/32A CDN for 5 AC power lines L1,L2,L3,N and PE, In = 32 A
** on special request, please contact factory for price and delivery
Shielded cables
CDN - S1/50 CDN for a single BNC cable 50 ohm, 100V/0.25ACDN - S1/75 CDN for a single BNC cable 75 ohm, 100V/0.25ACDN - S2 CDN for 2 BNC cable ports, 100V/0.25ACDN - S4 CDN for 4 BNC cable ports, 100V/0.25ACDN - S9 CDN for 9 shielded signal lines 100V/0.25A; SubD connectorCDN - S15 CDN for 15 shielded signal lines 100V/0.25A; SubD connectorCDN - S25 CDN for 25 shielded signal lines 100V/0.25A; SubD connector
Unshielded symmetrical lines
CDN - T2 CDN for 2 unshielded symmetrical lines 100V/0.25ARJ11 adaptor RJ 11 adaptor to be used with CDN T2CDN - T4 CDN for 4 unshielded symmetrical lines 100V/0.25ACDN - T8 - RJ45 CDN for 4 unshielded symmetrical RJ 45 lines 100V/0.25A
Unshielded unsymmetrical lines
CDN - AF2 CDN for 2 unshielded unsymmetrical lines 100V/1.5ACDN - AF3 CDN for 3 unshielded unsymmetrical lines 100V/1.5ACDN - AF4 CDN for 4 unshielded unsymmetrical lines 100V/1.5ACDN - AF8 CDN for 8 unshielded unsymmetrical lines 100V/1.5A
For special CDN‘s please call factory
Coupling clamps
EM 101 EM ClampFrequency range 0,15 - 1.000 MHzmax. 100 W for sinusoidal signals
F120-9A Current injection clampF33-2 Current monitor clamp
Calibration adapters and jigs, matching and termination resistors for all coupling/decoupling devices are available.
Technical data subject to change without notice.