SPECIAL SIZE FRAME DIMENSIONS Miscellaneous...
Transcript of SPECIAL SIZE FRAME DIMENSIONS Miscellaneous...
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-21
DOUBLE-HUNG
SPECIAL SIZE FRAME DIMENSIONS
Miscellaneous Formulas
1-WIDE VENT UNIT
2-WIDE VENT UNIT COMPOSITE
3-WIDE VENT UNIT COMPOSITE
MINIMUM14-1/2" W x 23-1/2" H (368 x 597)
28-1/2" H (724) Cottage and Contemporary EQUAL SASH MAXIMUM
48 Ft2 (4.46m2)54" W x 78" H (1 372 x 1 981)COTTAGE SASH MAXIMUM
54" W x 65-1/2" H (1 372 x 1 664)
CONTEMPORARY SASH MAXIMUM54" W x 65-1/2" H (1 372 x 1 664)
MINIMUM29-1/2" W x 23-1/2" H (749 x 597)
28-1/2" H (724) Cottage and ContemporaryEQUAL SASH MAXIMUM
72 Ft2 (4.46m2)108" W x 78" H (2 743 x 1 981)COTTAGE SASH MAXIMUM
108" W x 65-1/2" H (2 743 x 1 664)
CONTEMPORARY SASH MAXIMUM108" W x 65-1/2" H (2 743 x 1 664)
MINIMUM44-1/2" W x 23-1/2" H (1 130 x 597)
28-1/2" H (724) Cottage and ContemporaryEQUAL SASH MAXIMUM
72 Ft2 (4.46m2)112" W x 78" H (2 845 x 1 981)
COTTAGE SASH MAXIMUM112" W x 65-1/2" H (2 845 x 1 664)
CONTEMPORARY SASH MAXIMUM112" W x 65-1/2" H (2 845 x 1 664)
KEY:
AGW = Actual Glass Width AGH = Actual Glass Height ALGH = Actual Lower Glass Height AUGH = Actual Upper Glass Height FW = Frame Width
FH = Frame Height VGW = Visible Glass Width VGH = Visible Glass Height COW = Clear opening width COH = Clear opening height
COW COH Equal Vent
COH Cottage Vent
COH Contemporary Vent
CLEAR OPENING WITH CAM LOCK
Frame Width – 4.76
(FH / 2) – 4.375 FH – ALGH - 7.187 FH – AUGH – 4.854
CLEAR OPENING WITH AUTO LOCK (FH / 2) – 5.25 FH – ALGH - 8.062 FH – AUGH – 4.854
CLEAR OPENING WITH OPTIONAL MAXIMUM OPENING HARDWARE
(FH / 2) – 3.000 NA NA
Clear Opening Formulas
Miscellaneous Formulas
Standard Performance
Actual Glass Width
Actual Glass Height Standard Performance
Visible Glass Width
Performance Upgrade
Visible Glass Width
Visible Glass
Height Lower Glass Upper Glass
1-W
IDE Vent-equal
FW - 5-1/4"
(FH - 5-5/8) / 2 (FH - 5-5/8) / 2
AGW - 1-1/8" FW - 3-15/16" AGH - 1-1/8"Cottage (FH -5-5/8) X .6 (FH - 5-5/8) X .4
Contemporary (FH - 5-5/8) X .4 (FH - 5-5/8) X .6
2-W
IDE Vent-equal
(FW / 2) - 5-1/2
(FH - 5-5/8) / 2 (FH - 5-5/8) / 2
AGW - 1-1/8" AGH - 1-1/8"Cottage (FH -5-5/8) X .6 (FH - 5-5/8) X .4
Contemporary (FH - 5-5/8) X .4 (FH - 5-5/8) X .6
3-W
IDE Vent-equal
(FW / 3) - 5-19/32"
(FH - 5-5/8) / 2 (FH - 5-5/8) / 2
AGW - 1-1/8" AGH - 1-1/8"Cottage (FH -5-5/8) X .6 (FH - 5-5/8) X .4
Contemporary (FH -5-5/8) X .4 (FH - 5-5/8) X .6
General Notes:
• Rough Opening—Frame Dimension + 1/2"• Keep frame di men sions to the near est 1/8" increment
• Maximum frame area = 48 ft2
• 2-Wide and 3-Wide units are composites with multiple windows in one frame with integral mullions
Max Opening Hardware Requirements:Unit must be standard performance
Must not have limited opening hardware
Unit must have equal sash split
Frame width must be ≥ 29.5
Frame height must be ≥ 55.5
Frame height must be ≤ 72
Clear Opening Area (ft²) = (COW x COH) / 144
Frame Area (ft²) = (Frame Width x Frame Height) / 144
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-22
DOUBLE-HUNG
SIZE TABLES
Single Units - Equal Sash
2-6/4-10
2-6/4-2
2-6/4-6
2-6/4-0
2-6/3-10
2-6/3-6
2-6/3-2
2-6/3-0
2-6/2-6
4-0/4-103-6/4-103-4/4-103-2/4-103-0/4-102-8/4-102-4/4-102-0/4-101-6/4-10
3-2/4-2 4-0/4-23-6/4-23-4/4-23-0/4-22-8/4-22-4/4-22-0/4-21-6/4-2
3-2/4-6
3-2/4-0
3-2/3-10
3-2/3-6
3-2/3-2
3-2/3-0
3-2/2-6
4-0/4-63-6/4-63-4/4-63-0/4-62-8/4-62-4/4-62-0/4-61-6/4-6
4-0/4-03-6/4-03-4/4-03-0/4-02-8/4-02-4/4-02-0/4-01-6/4-0
4-0/3-103-6/3-103-4/3-103-0/3-102-8/3-102-4/3-102-0/3-101-6/3-10
4-0/3-63-6/3-63-4/3-63-0/3-62-8/3-62-4/3-62-0/3-61-6/3-6
4-0/3-23-6/3-23-4/3-23-0/3-22-8/3-22-4/3-22-0/3-21-6/3-2
4-0/3-03-6/3-03-4/3-03-0/3-02-8/3-02-4/3-02-0/3-01-6/3-0
4-0/2-63-6/2-63-4/2-63-0/2-62-8/2-62-4/2-62-0/2-61-6/2-6
(762)(749)
"/ 21292' 6"
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(1 2
07)
(1 3
59)
(1 3
72)
(1 2
19)
"/ 21
53"
/ 2147
29(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
4' 6
"4'
0"
3' 1
0"3'
6"
3' 2
"2'
6"
3' 0
"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
1-Wide Vent
1AEAEAEAE1AE 2E
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-23
DOUBLE-HUNG
2-6/5-10
2-6/6-6
2-6/6-0
2-6/5-6
2-6/5-2
2-6/5-0
3-2/5-10 4-0/5-103-6/5-103-4/5-103-0/5-102-8/5-102-4/5-102-0/5-101-6/5-10
3-2/6-6
3-2/6-0
3-2/5-6
3-2/5-2
4-0/6-63-6/6-63-4/6-63-0/6-62-8/6-62-4/6-62-0/6-61-6/6-6
4-0/6-03-6/6-03-4/6-03-0/6-02-8/6-02-4/6-02-0/6-01-6/6-0
4-0/5-63-6/5-63-4/5-63-0/5-62-8/5-62-4/5-62-0/5-61-6/5-6
4-0/5-23-6/5-23-4/5-23-0/5-22-8/5-22-4/5-22-0/5-21-6/5-2
3-2/5-0 4-0/5-03-6/5-03-4/5-03-0/5-02-8/5-02-4/5-02-0/5-01-6/5-0
(762)(749)
"/ 21292' 6"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
(1 7
65)
(1 7
78) "
/ 21695'
10"
(1 9
69)
(1 9
81) "
/ 21776'
6"
(1 8
16)
(1 8
29) "
/ 21716'
0"
(1 6
64)
(1 6
76) "
/ 21655'
6"
(1 5
62)
(1 5
75) "
/ 21615'
2"
1-Wide Vent
(1 5
11)
(1 5
24) "
/ 21595'
0"
1E
E
1E
AE1E
AE1E2E E E E
EEEE
E E E E E
EEEEE
E E E E E
EEEEEE
1E
1E
1E
1E
1E
2E
2E
SIZE TABLES
Single Units - Equal Sash
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-24
DOUBLE-HUNG
5-0/4-10
5-0/5-2
5-0/4-2
5-0/5-0
5-0/4-6
5-0/4-0
5-0/3-10
5-0/3-6
5-0/3-2
5-0/3-0
5-0/2-6
3-0/4-10 6-0/4-105-4/4-104-8/4-104-0/4-10
6-0/5-25-4/5-24-8/5-24-0/5-23-0/5-2
6-0/4-25-4/4-24-8/4-24-0/4-23-0/4-2
6-0/5-05-4/5-04-8/5-04-0/5-03-0/5-0
6-0/4-65-4/4-64-8/4-64-0/4-63-0/4-6
6-0/4-05-4/4-04-8/4-04-0/4-03-0/4-0
6-0/3-105-4/3-104-8/3-104-0/3-103-0/3-10
6-0/3-65-4/3-64-8/3-64-0/3-63-0/3-6
6-0/3-25-4/3-24-8/3-24-0/3-23-0/3-2
6-0/3-05-4/3-04-8/3-04-0/3-03-0/3-0
6-0/2-65-4/2-64-8/2-64-0/2-63-0/2-6
(1 524)
"/ 21
(1 511)
595' 0"Opening
Frame
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 5
62)
(1 5
75) "
/ 21615'
2"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(1 829)
"/ 21
(1 816)
716' 0"
"/ 21
(1 219)(914) (1 422)
"/ 21353' 0"
(902)
"/ 21474' 0"
(1 207)
554' 8"
(1 410)(1 626)
"/ 21
(1 613)
635' 4"
2-Wide Vent
(1 2
07)
(1 5
11)
(1 3
59)
(1 5
24)
(1 3
72)
(1 2
19)
"/ 21
59"
/ 2153
"/ 21
4729
(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
5' 0
"4'
6"
4' 0
"3'
10"
3' 6
"3'
2"
2' 6
"3'
0"
1AE
2E
2E
1E
1E
SIZE TABLES
2-Wide Composites with Integral Mullion - Equal Sash
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-25
DOUBLE-HUNG
8-0/4-107-0/4-106-8/4-10
8-0/5-27-0/5-26-8/5-2
8-0/4-27-0/4-26-8/4-2
8-0/5-07-0/5-06-8/5-0
8-0/4-67-0/4-66-8/4-6
8-0/4-07-0/4-06-8/4-0
8-0/3-107-0/3-106-8/3-10
8-0/3-67-0/3-66-8/3-6
8-0/3-27-0/3-26-8/3-2
8-0/3-07-0/3-06-8/3-0
8-0/2-67-0/2-66-8/2-6
6-4/4-10
6-4/5-2
6-4/4-2
6-4/5-0
6-4/4-6
6-4/4-0
6-4/3-10
6-4/3-6
6-4/3-2
6-4/3-0
6-4/2-6
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 5
62)
(1 5
75) "
/ 21615'
2"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(1 2
07)
(1 5
11)
(1 3
59)
(1 5
24)
(1 3
72)
(1 2
19)
"/ 21
59"
/ 2153
"/ 21
4729
(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
5' 0
"4'
6"
4' 0
"3'
10"
3' 6
"3'
2"
2' 6
"3'
0"
OpeningFrame 95
(2 438)
8' 0"
(2 426)
"/ 2183
(2 134)
7' 0"
(2 121)
"/ 21
(2 032)
6' 8"79
(2 219)
"/ 21
2-Wide Vent(1 930)
"/ 21
(1 918)
756' 4"
AEAEAE
AE1E
1AE
EEE
E E E
2E
E
SIZE TABLES
2-Wide Composites with Integral Mullion - Equal Sash
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-26
DOUBLE-HUNG
5-0/5-10
5-0/6-6
5-0/6-0
5-0/5-6
8-0/5-107-0/5-106-8/5-10
8-0/6-67-0/6-66-8/6-6
8-0/6-07-0/6-06-8/6-0
8-0/5-67-0/5-66-8/5-6
6-4/5-10
6-0/5-105-4/5-104-8/5-104-0/5-103-0/5-10
6-4/6-6
6-4/6-0
6-4/5-6
6-0/6-65-4/6-64-8/6-64-0/6-63-0/6-6
6-0/6-05-4/6-04-8/6-04-0/6-03-0/6-0
6-0/5-65-4/5-64-8/5-64-0/5-63-0/5-6
(1 626)
"/ 21
(1 511)
595' 0"
(1 7
65)
(1 7
78) "
/ 21695'
10"
(1 9
69)
(1 9
81) "
/ 21776'
6"
(1 8
16)
(1 8
29) "
/ 21716'
0"
(1 6
64)
(1 6
76) "
/ 21655'
6"
OpeningFrame 95
(2 438)
8' 0"
(2 426)
"/ 2183
(2 134)
7' 0"
(2 121)
"/ 21
(2 032)
6' 8"79
(2 219)
"/ 21
OpeningFrame
(1 930)
"/ 21
(1 918)
756' 4"
(1 829)
"/ 21
(1 816)
716' 0"
"/ 21
(1 219)(914) (1 422)
"/ 21353' 0"
(902)
"/ 21474' 0"
(1 207)
554' 8"
(1 410)(1 626)
"/ 21
(1 613)
635' 4"
(1 7
65)
(1 7
78) "
/ 21695'
10"
(1 9
69)
(1 9
81) "
/ 21776'
6"
(1 8
16)
(1 8
29) "
/ 21716'
0"
(1 6
64)
(1 6
76) "
/ 21655'
6"
2-Wide Vent
1E
1E
E
AE1E
2E
1E
1E
1E
E
EE
E
E
E
E
E
E
E E E
E
E
EE
EE
E E E
SIZE TABLES
2-Wide Composites with Integral Mullion - Equal Sash
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-27
DOUBLE-HUNG
SIZE TABLES
3-Wide Composites with Integral Mullion - Equal Sash
7-6/4-10
7-6/4-2
7-6/4-6
7-6/4-0
7-6/3-10
7-6/3-6
7-6/3-2
7-6/3-0
7-6/2-6
9-0/4-108-0/4-107-0/4-106-0/4-104-6/4-10
9-0/4-28-0/4-27-0/4-26-0/4-24-6/4-2
9-0/4-68-0/4-67-0/4-66-0/4-64-6/4-6
9-0/4-08-0/4-07-0/4-06-0/4-04-6/4-0
9-0/3-108-0/3-107-0/3-106-0/3-104-6/3-10
9-0/3-68-0/3-67-0/3-66-0/3-64-6/3-6
9-0/3-28-0/3-27-0/3-26-0/3-24-6/3-2
9-0/3-08-0/3-07-0/3-06-0/3-04-6/3-0
9-0/2-68-0/2-67-0/2-66-0/2-64-6/2-6
"/ 21
(2 286)
897' 6"
(2 273)
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(2 743)
"/ 21
(2 731)
1079' 0"
"/ 21
(1 829)(1 372) (2 134)
"/ 21534' 6"
(1 359)
"/ 21716' 0"
(1 816)
837' 0"
(2 121)(2 438)
"/ 21
(2 426)
958' 0"
3-Wide Vent
Opening
Frame
(1 2
07)
(1 3
59)
(1 3
72)
(1 2
19)
"/ 21
53"
/ 2147
29(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
4' 6
"4'
0"
3' 1
0"3'
6"
3' 2
"2'
6"
3' 0
"
1AE
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-28
DOUBLE-HUNG
7-0/5-10
7-0/6-6
7-0/6-0
7-0/5-6
7-0/5-2
7-0/5-0
9-0/5-108-0/5-107-6/5-106-0/5-104-6/5-10
9-0/6-68-0/6-67-6/6-66-0/6-64-6/6-6
9-0/6-08-0/6-07-6/6-06-0/6-04-6/6-0
9-0/5-68-0/5-67-6/5-66-0/5-64-6/5-6
9-0/5-28-0/5-27-6/5-26-0/5-24-6/5-2
9-0/5-08-0/5-07-6/5-06-0/5-04-6/5-0
"/ 21
(2 286)
897' 6"
(2 273)(2 743)
"/ 21
(2 731)
1079' 0"
"/ 21
(1 829)(1 372) (2 134)
"/ 21534' 6"
(1 359)
"/ 21716' 0"
(1 816)
837' 0"
(2 121)(2 438)
"/ 21
(2 426)
958' 0"Opening
Frame
(1 7
65)
(1 7
78) "
/ 21695'
10"
(1 9
69)
(1 9
81) "
/ 21776'
6"
(1 8
16)
(1 8
29) "
/ 21716'
0"
(1 6
64)
(1 6
76) "
/ 21655'
6"
(1 5
62)
(1 5
75) "
/ 21615'
2"
3-Wide Vent
(1 5
11)
(1 5
24) "
/ 21595'
0"
1E
1E
E
AE1E
2E
2E
2E
1E
1E
1E
1E
1E
E
E
E
E E
SIZE TABLES
3-Wide Composites with Integral Mullion - Equal Sash
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
A = Unit does not meet egress if using optional Autolock hardware; unit may meet second value if one is shown. Autolock hardware is not compatible with Maximum opening hardware.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-29
DOUBLE-HUNG
2-6/4-10
2-6/4-2
2-6/4-6
2-6/4-0
2-6/3-10
2-63-6
2-6/3-2
2-6/3-0
2-6/2-6
4-0/4-103-6/4-103-4/4-103-2/4-103-0/4-102-8/4-102-4/4-102-0/4-101-6/4-10
3-2/4-2 4-0/4-23-6/4-23-4/4-23-0/4-22-8/4-22-4/4-22-0/4-21-6/4-2
3-2/4-6
3-2/4-0
3-2/3-10
3-2/3-6
3-2/3-2
3-2/3-0
3-2/2-6
4-0/4-63-6/4-63-4/4-63-0/4-62-8/4-62-4/4-62-0/4-61-6/4-6
4-0/4-03-6/4-03-4/4-03-0/4-02-8/4-02-4/4-02-0/4-01-6/4-0
4-0/3-103-6/3-103-4/3-103-0/3-102-8/3-102-4/3-102-0/3-101-6/3-10
4-0/3-63-6/3-63-4/3-63-0/3-62-8/3-62-4/3-62-0/3-61-6/3-6
4-0/3-23-6/3-23-4/3-23-0/3-22-8/3-22-4/3-22-0/3-21-6/3-2
4-0/3-03-6/3-03-4/3-03-0/3-02-8/3-02-4/3-02-0/3-01-6/3-0
4-0/2-63-6/2-63-4/2-63-0/2-62-8/2-62-4/2-62-0/2-61-6/2-6
(762)(749)
"/ 21292' 6"
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(1 2
07)
(1 3
59)
(1 3
72)
(1 2
19)
"/ 21
53"
/ 2147
29(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
4' 6
"4'
0"
3' 1
0"3'
6"
3' 2
"2'
6"
3' 0
"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
1-Wide Vent
SIZE TABLES
Single Units - Cottage Sash
Not to scale.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-30
DOUBLE-HUNG
2-6/5-6
2-6/5-2
2-6/5-0
3-2/5-6
3-2/5-2
4-0/5-63-6/5-63-4/5-63-0/5-62-8/5-62-4/5-62-0/5-61-6/5-6
4-0/5-23-6/5-23-4/5-23-0/5-22-8/5-22-4/5-22-0/5-21-6/5-2
3-2/5-0 4-0/5-03-6/5-03-4/5-03-0/5-02-8/5-02-4/5-02-0/5-01-6/5-0
(762)(749)
"/ 21292' 6"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
(1 6
64)
(1 6
76) "
/ 21655'
6"
(1 5
62)
(1 5
75) "
/ 21615'
2"
(1 5
11)
(1 5
24) "
/ 21595'
0"
1-Wide Vent
SIZE TABLES
Single Units - Cottage Sash
Not to scale.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-31
DOUBLE-HUNG
SIZE TABLES
Single Units - Contemporary Sash
2-6/4-10
2-6/4-2
2-6/4-6
2-6/4-0
2-6/3-10
2-6/3-6
2-6/3-2
2-6/3-0
2-6/2-6
4-0/4-103-6/4-103-4/4-103-2/4-103-0/4-102-8/4-102-4/4-102-0/4-101-6/4-10
3-2/4-2 4-0/4-23-6/4-23-4/4-23-0/4-22-8/4-22-4/4-22-0/4-21-6/4-2
3-2/4-6
3-2/4-0
3-2/3-10
3-2/3-6
3-2/3-2
3-2/3-0
3-2/2-6
4-0/4-63-6/4-63-4/4-63-0/4-62-8/4-62-4/4-62-0/4-61-6/4-6
4-0/4-03-6/4-03-4/4-03-0/4-02-8/4-02-4/4-02-0/4-01-6/4-0
4-0/3-103-6/3-103-4/3-103-0/3-102-8/3-102-4/3-102-0/3-101-6/3-10
4-0/3-63-6/3-63-4/3-63-0/3-62-8/3-62-4/3-62-0/3-61-6/3-6
4-0/3-23-6/3-23-4/3-23-0/3-22-8/3-22-4/3-22-0/3-21-6/3-2
4-0/3-03-6/3-03-4/3-03-0/3-02-8/3-02-4/3-02-0/3-01-6/3-0
4-0/2-63-6/2-63-4/2-63-0/2-62-8/2-62-4/2-62-0/2-61-6/2-6
(762)(749)
"/ 21292' 6"
(1 4
61)
(1 4
73) "
/ 21574'
10"
(1 2
57)
(1 2
70) "
/ 21494'
2"
"/ 21
41
(1 2
07)
(1 3
59)
(1 3
72)
(1 2
19)
"/ 21
53"
/ 2147
29(749
)(7
62)
(902
)(1
054
)(9
53)
(1 1
56)
(1 0
67)
(1 1
68)
(965
)(9
14)
45"
/ 2137
"/ 21
"/ 21
35"
/ 21
4' 6
"4'
0"
3' 1
0"3'
6"
3' 2
"2'
6"
3' 0
"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
1-Wide Vent
Not to scale.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-32
DOUBLE-HUNG
SIZE TABLES
Single Units - Contemporary Sash
2-6/5-6
2-6/5-2
2-6/5-0
3-2/5-6
3-2/5-2
4-0/5-63-6/5-63-4/5-63-0/5-62-8/5-62-4/5-62-0/5-61-6/5-6
4-0/5-23-6/5-23-4/5-23-0/5-22-8/5-22-4/5-22-0/5-21-6/5-2
3-2/5-0 4-0/5-03-6/5-03-4/5-03-0/5-02-8/5-02-4/5-02-0/5-01-6/5-0
(762)(749)
"/ 21292' 6"
(965)
"/ 21
(953)
373' 2"
47
(1 219)
4' 0"
(1 207)
"/ 2141
(1 067)
3' 6"
(1 054)
"/ 21
(914)
"/ 21
(902)
353' 0"
"/ 21
(610)(457) (711)
"/ 21171' 6"
(445)
"/ 21232' 0"
(597)
272' 4"
(699)(1 016)(813)
3' 4"39
(1 003)
"/ 21
(800)
312' 8"
"/ 21
OpeningFrame
(1 6
64)
(1 6
76) "
/ 21655'
6"
(1 5
62)
(1 5
75) "
/ 21615'
2"
(1 5
11)
(1 5
24) "
/ 21595'
0"
1-Wide Vent
EEE1E 1E
Not to scale.
Egress Notes:
Check all applicable local codes for emergency egress requirements.
E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2.
E2 = With optional maximum opening hardware, window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2.
See Design Data pages in this section for clear opening dimensions.
Pella® 350 Series
Pella 2018 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com V350-DH-33
DOUBLE-HUNG
Call Size
Masonry
Buck
Frame
Tip to Tip
FL-12
FL-13
FL-14
FL-15
FL-16 FL-H36
FL-H35
FL-H34
FL-H33
FL-H32
FL-26
FL-25
FL-24
FL-23
FL-22
FL-36
FL-35
FL-34
FL-33
FL-32
"1 /
4"
5 /8"
3 /8 "
3 /8 "
3 /8
"7 /
8"5 /
8 "5 /
8 "5 /
8
"1 /
4"
1 /4
"1/ 4
"7/ 8
"3/ 8
"1/ 8
"1/ 8
"3/ 4"1/ 4
"3/ 4
"1/ 2
"1/ 2
"7/ 8
"3/ 8
"1/ 8
"1/ 8
52
53
52
53
3
36"
37"
36
37
2H31
25
26
25
2719
18
19
18
6
75 75"
76"
76"
63"
63"
62"
62
54
49 49 505038 383737
32 26
"
25 25"
26"
SIZE TABLES
5/8" Integral Flange
Not to scale.