SPECFICATION & ESTIMATION OF THE PROPOSED …
Transcript of SPECFICATION & ESTIMATION OF THE PROPOSED …
SPECFICATION & ESTIMATION OF THE PROPOSED
CONSTRUCTION OF A RESIDENTIAL BUILDING AT
Rs. 1800 per SQ.FT.
FOUNDATION:
The foundation shall be designed for
THREE floors; the type of foundation (Isolated
column footing) shall be made as per the design
given by the Structural Engineer which will be
based on the soil condition. The soil will be
tested to ascertain load bearing capacity and
accordingly foundation will be designed.
Note: If the soil type is loose sand, loose
gravel or clay, Foundation design will be
changed. Based upon the design of foundation,
the cost of foundation shall be charged as
additional cost.
BASEMENT:
The minimum basement
height shall be maintained to 3.0
feet from existing Natural Ground
level. The earth filling for the
basement height up to 3.0 feet shall be
made from the existing ground level. For the basement filling good quality filling
sand will be used. Plinth and Backfilling area shall be filled with good quality
filling sand or with Quarry dust (compacted evenly
throughout the area).
FLOORING:
PCC will be laid over the compaction, Plinth area
shall be provided with concrete floor or Paver blocks
will be laid over the compacted set-back area.
STRUCTURE:
RCC framed Structure
will be as per seismic zone 3
designs and the outer walls of
the building shall be 9" thick
brick work and internal wall of
the building shall be 9” or 4.5"
thick brick work. Fired Clay
bricks will be used for the
brick work. The lintel levels
are 7’0” height from the floor
level and the roof height shall
be 10’0” (Including roof slab
thickness).
Parapet wall shall be 9 “thick
brick work and 3.0 feet height (Provided with canopy rings). Providing and applying
12mm thick cement plaster.
FLOOR HEIGHT:
Stilt floor height shall be 2.5 meters
(8’2.42”) and all other floor height shall be
3.0 (10’0”) meters including the roof slab
thickness. Top floor height shall be 2.75
meters (8’4.5”). Total height of the proposed
building shall be 8.5 meters (9’10.11”).
(Excludes: Basement rise, Head room and
parapet wall)
Note: Floor heights are Subject to
CMDA Clearance.
CONCRETE GRADE:
Concrete grade M20 will be used for the columns, beams and roof slab as per the
structural engineer’s design.
(i) Cement:
RCC:-
For roof slab OPC 53 grade of high
quality cement of any brand will be
used. The price may starts from
Rs.390/ bag.
For Other structural elements like
Beam, Column & Lintel cum sunshade, OPC 53
grade high quality cement any brand will be used. The price may starts from
Rs.360/ bag.
For Plastering and Brick work, PPC or OPC 43 grade of cement will be
used. The price may starts from Rs.360/ bag.
Steel:
Fe500 grade Thermo-
mechanically treated ribbed
high tensile strength steel of any
brand will be used.
CAR PARKING AREA:
Parking tile will be given for the flooring. Electrical and plumbing points will
be provided.
COMMON AREA:
Common area like Staircase and landing area will be provided with anti-skid
tile floor (Rs 35/sq.ft.).
HANDRAIL:
The support and railings in staircases will be of S.S hand Railing for one side
only.
FLOOR SPACE, FLOORING & WALL TILES:
Living room, Bedroom: Vitrified tiles (24x24inches Cost up to Rs.50/- per
Sq.ft) for entire area. Built in shoe rack and showcase in 9” wall.
(i) Kitchen:
Vitrified tiles ((24x24inches Cost up
to Rs.50/- per Sq.ft). Kitchen slab with
18mm granite top as per architect drawing
to accommodate space for mixer grinder,
microwave etc. (Cost of granite Rs.100/Sq.
ft) Vitrified Designer wall Tiles up to two
feet height above the kitchen slab. (Cost of
Tile Rs. 35/- Per Sq.ft.) Stainless sink with
10” depth will be provided. (Grade: SS 303).
(ii) Bathrooms and Washing area:
Vitrified Designer tiles up to 7’ height in Toilet area (Cost up to Rs 35/- Per
Sq.ft) and Anti-Skid flooring tiles. Providing and applying integrated cement based
waterproof plaster treatment to floor and wall of toilet blocks including grouting
with cement slurry along with the concrete work.
(iii) Terrace flooring:
Terrace slab waterproof shall be integrated cement
based waterproofing treatment and plaster treatment to
floor. Cement paste with waterproofing compound and
with traditional bricks bats / fine coarse aggregates
waterproof and temperature control method.
CARPENTRY:
Main door frame and shutter shall be provided with
Teak Wood melamine polished on both sides and
Hardware’s such as (Lever Handle Lock, Tower bolt,
Door Stopper, Eye piece and safety chain).
All other door frames will be of teak wood and
painted with designer
Flush Shutters and
Hardware’s such as
(Lever Handle Lock,
Tower bolt, Door
Stopper)
Windows frame
and shutters will be in UPVC Sliding doors with 4mm Plain Glass. Ventilator
Provision as per the design (UPVC) PVC frame and door shall be provided for the
toilet.
M.S FABRICATION:
Providing and fixing MS grill for window / ventilator of suitable size with 2
coats of synthetic enamel paint over a coat of primer.
ELECTRICAL:
Distribution boards and Cubicle panel of 16g board suitable three phase
connection and designed for termination of Incoming cables, outgoing cables wires
etc., with cable chamber box (Include all required hardware’s) at every unit of
“Standard” brand. Providing and fixing Earth link heavy of G.I pipe, No.8 SWG
copper wires for 5m- 10m and earth strip of size (25x3x0.5) m3 with necessary
insulators Concealed wiring will be provided for all the portions with ISI wires.
One Split A.C. point is provided in all Bedrooms and channeled typical routing.
Modular Switches shall be provided with Anchor.
Centralized cabling system for Telephone, Data and DTH in all Rooms. Telephone
point for each portion provided One Geyser and Exhaust point will be provided in
all bathrooms and Kitchen, Washing machine point in balcony.
Note Excludes: Cables and terminations to the main board (Payment towards
EB Govt.) Electrical Fittings.
PLUMBING:
C.P.V.C. SDR Pipes shall be used for all concealed work. U.P.V.C. Pipes for all
drainage lines. 4kg pipe for open lines and 6kg for concealed lines. 1000 liters PVC
overhead tank will be placed on the terrace.
Ball valve, CP (brass stop cocks heavy, brass bib c ocks 15mm dia.
short/long body heavy (with flange), S.S. grating 100mm, health faucet set,
bottle trap 15mm dia, etc.) Wall mixer, Angle cock, Taps, 2in1 Taps of required dia
and open (Conforming to IS: 8931, IS: 778- Class I, Parryware (basic quality) as per
requirement. E. W.C. white color wall mount, with tank shall be provided.
(Parryware of basic quality). Wall mounted basin (Parryware of basic quality).
PAINTING:
The Interior surface of all walls
(Asian Royale Emulsion). Applying
two coat of wall Putty, One coat of
wall primer and applying two coats
of Emulsion paint. The external
surface of walls, Ceiling etc. (Asian
Paints- Ace) Applying one coat of exterior primer and two coats of exterior emulsion
paint. Two Coat of synthetic enamel paint over a coat of primer for Window grills
and Gate.
OVERHEAD TANK:
PVC overhead tank of 1000 litres capacity will be
provided over terrace floor with proper support section.
SEPTIC TANK:
The septic tank of 5000 litres capacity with R.C.C. base
slab, side walls, two baffle walls and cover slab, and RCC
foundation will be provided over PCC 1:4:8 & Sand filling. Inlet and outlet
chambers, manholes and vent pipes are provided as shown in the sketch.
1000 litres
SOAK PIT:
The soak pit, consisting basically of a
simple pit will be provided for15 feet deep. It
will be located at a safe distance from a
drinking water source. The required number of
concrete earth chamber ring will be placed in
the pit. The pipe lines will be provided to the
kitchen and bathroom to collect the waste to pit.
SCOPE OF OWNERS:
Power supply during the entire process of construction.
Water supply during the entire process of construction.
EB Transform connection and main cable routing.
Any decorative works, (stone finish, cladding, glass items SS grills etc)
Any external development, (apart from work mentioned the cost).
Electrical fittings like fan, lights fitting and fixtures, Air conditioners
Water treatment plant if required