 WHE RE TH E WOR LD TU RNS F OR P OWER Exclusively from your Caterpillar ® dealer GEPH17SP (1-Phase) 50 HZ ST ANDBY 17.5 kV A / 17.5 kW FEATURES GENERATING SET Complete system designed and built at ISO9001 certified facility Factory tested to design specifications at full load conditions Fully engineered with a range of options and accessories ENGINE Industrial water cooled diesel engine Governor, mechanical Electrical system, 12 VDC Cartridge type fuel and oil filters Air filter Battery(s), rack and cables ALTERNATOR Self excited brushless generator Insulation system, class H Drip proof alternator air intake (IP23) Electrical design in accordanc e with BS5000 Part 99, IEC60034-1, VDE0530, UTE51 100 CONTROL SYSTEM LCP2 control panel Vibration isolated sheet steel enclosure with hinged lockable door MOUNTING ARRANGEMENT Heavy-duty fabricated steel base with lifting points Anti-vibration pads to ensure vibration isolation Engine coupled to alternator with flexible disc cou pling Baseframe incorporates metal fuel tank, 8 hours running capacity EXHAUST SYSTEM Heavy duty industrial capacity exhaust silencer (approximately 25 dB reduction) supplied loose COOLING SYSTEM Standard ambie nt temp era ture s up to 50° C (122° F) Fan, fan drive and chargi ng alternator fully guarded Antifreeze protection coolant CIRCUIT BREAKER 3-pole miniature circuit breaker (mcb ) < 100 amps Vibration isolated sheet steel enclosure with removable cover plate Outgoing cable stub-up area directly below circuit breaker AUTOMATIC VOL T AGE REGULATOR V oltage regul ation ±1.0 % Provides fast recovery from transient load changes EQUIPMENT FINISH All electroplated hardware Anticorrosive paint protection High gloss polyurethane paint for durability and scu ff resi stance QUALITY ST ANDARDS BS4999, BS5000, BS5514, IEC60034, VDE0530 DOCUMENTATION Operation and maintenance manuals provided Wiring diagrams included WARRANTY All equipment carries full manufacturer's warranty. Extended warranty terms available. DIESEL GENERA TING SE T

Transcript of Spec Sheet Geph17sp

Page 1: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 1/6

 W H E R E T H E W O R L D T U R N S F O R P O W E R

Exclusively from your Caterpillar ®  dealer 

GEPH17SP (1-Phase)

50 HZ

STANDBY 17.5 kVA / 17.5 kW

FEATURES

GENERATING SET● Complete system designed and built at ISO9001

certified facility● Factory tested to design specifications at full load

conditions● Fully engineered with a range of options

and accessories

ENGINE● Industrial water cooled diesel engine●

Governor, mechanical● Electrical system, 12 VDC● Cartridge type fuel and oil filters● Air filter● Battery(s), rack and cables

ALTERNATOR● Self excited brushless generator● Insulation system, class H● Drip proof alternator air intake (IP23)● Electrical design in accordance with BS5000 Part 99,

IEC60034-1, VDE0530, UTE51100

CONTROL SYSTEM●

LCP2 control panel● Vibration isolated sheet steel enclosure with hinged

lockable door

MOUNTING ARRANGEMENT● Heavy-duty fabricated steel base with lifting points● Anti-vibration pads to ensure vibration isolation● Engine coupled to alternator with flexible

disc coupling● Baseframe incorporates metal fuel tank, 8 hours

running capacity

EXHAUST SYSTEM● Heavy duty industrial capacity exhaust silencer

(approximately 25 dB reduction) supplied loose

COOLING SYSTEM● Standard ambient temperatures up to 50° C (122° F)● Fan, fan drive and charging alternator fully guarded● Antifreeze protection coolant

CIRCUIT BREAKER● 3-pole miniature circuit breaker (mcb) < 100 amps● Vibration isolated sheet steel enclosure with

removable cover plate● Outgoing cable stub-up area directly below circuit

breakerAUTOMATIC VOLTAGE REGULATOR● Voltage regulation ±1.0 %● Provides fast recovery from transient load changes

EQUIPMENT FINISH● All electroplated hardware● Anticorrosive paint protection● High gloss polyurethane paint for durability and

scuff resistance

QUALITY STANDARDS● BS4999, BS5000, BS5514, IEC60034, VDE0530

DOCUMENTATION● Operation and maintenance manuals provided● Wiring diagrams included

WARRANTY● All equipment carries full manufacturer's warranty.

Extended warranty terms available.

D I E S E L

G E N E R A T I N G S E T

Page 2: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 2/6

5 0 H z S T A N D B Y 1 7 . 5 k V A / 1 7 . 5 k W

Exclusively from your Caterpillar ®  dealer 

OPTIONAL EQUIPMENT*

*Some options may not be available on all models.Not all options are listed.

Cooling System Coolant heater

50% Anti-Freeze (Protection to -36°C)Fuel System Low fuel level alarm

Silencer System — Open Unit Engine mounted level 2 silencerOverhead mounting kit

Enclosures Sound attenuated enclosurePerspex control panel viewing in lockable access door

Handling/Trailers Single point liftFixed height drawbar 2 wheel trailerAdjustable height drawbar 2 wheel trailer

Controls LCP0 Series panelLCP1 Series panelAccess 2000 panelAccess 4000 panelLube oil pressure gaugeCoolant temperature gaugeBattery charger

Circuit Breaker Upgrades from 3-pole to 4-pole breaker32A CEE Form socket 50 Hz only63A CEE Form socket 50 Hz onlyEarth Leakage protection for main output 300 mA, CB trip

Certification European CE certification

Page 3: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 3/6

5 0 H z S T A N D B Y 1 7 . 5 k V A / 1 7 . 5 k W

Exclusively from your Caterpillar ®  dealer 

ALTERNATOR

M a k e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O l y m p i a nModel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LLB1012J

Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Self-excited, brushless

Voltage regulation. . . . . . . . . . . . . . . . ±1.0% at steady state fromfrom no load to full load

Frequency. . . . . . . . . . . . . . . . . . . . . ±1.0% for constant load fromno load to full load

Waveform distortion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THD <4%

Radio interference. . . . . . . . . . . . . . Compliance with BS800 andVDE Class G&N

Telephone Interference . . . . . . . . . . . . . . . . . . . . TIF <50, THF <2%

Overspeed limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 500 rpm

Insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class H

Temperature rise . . . . . . . . . . . . . . . . . . . . . . Within Class H limits

Deration . . . . . . . . . . . . . . . Consult factory for available outputs

ENGINE

Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perkins

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403C-15G

Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-Cycle

Aspiration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Naturally aspirated

Cylinder configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In-line 3

Displacement — L (cu in) . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 (91.3)

Bore/stroke — mm (in) . . . . . . . . . . . . . . . . . . . . . . 84/100 (3.3/3.9)

Compression ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.5:1

Engine speed — rpm50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000

Piston speed — m/sec (ft/sec)50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.0 (29.5)

Maximum power at rated rpm — kW (hp)

Standby50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.9 (32.1)

BMEP — kPa (psi)Standby

50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650 (94.2)

Regenerative power — kW (hp)50 Hz ...........................................................................TBA

Motor starting capability — kW (hp)50 Hz ...........................................................................TBA

GovernorType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MechanicalClass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO 8528 G2

SPECIFICATIONS

Consult your Olympian representative for more information

GENERATING SET DIMENSIONS ANDWEIGHTS

Length Width Height Weight*Model mm (in) mm (in) mm (in) kg (lb)

GEPH17SP 1320 (520) 552 (21.7) 1258 (49.5) TBA

*Includes oil and coolant

Note: General configuration not to beused for installation. See generaldimension drawings for detail.

Page 4: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 4/6

50 Hz

Alternator Technical Data 415/240V 400/230V 380/220V

Motor Starting Capability:Self Excited (kVA 24 23 21

Full Load EfficiencyStandby % 83.5 82.9 82.2Prime %

Reactances (per unit) Xd 4.11 4.11 4.11Saturated X'd 0.27 0.27 0.27Reactances X"d 0.134 0.134 0.134are shown Xqapplicable to the X"qstandby rating

Time Constants:t’d t"d t'do ta

40ms. 5ms. 615ms. 10ms.

5 0 H z S T A N D B Y 1 7 . 5 k V A / 1 7 . 5 k W

Exclusively from your Caterpillar ®  dealer 

GEPH17SP (1-Phase)

Consult your Olympian representative for more information.

**dBA levels are for guidance only**Fuel consumption data at indicated load with diesel fuel with a specific gravity of 0.85 andconforming to BS2869:1998 Class A2.

50 HzGenerating Set Technical Data Standby

Package PerformancePower rating kVA (kW) 17.5 (17.5)

Lubricating SystemType: OilOil filter: Spin-on, full flowOil cooler: CoolantOil type required: API CH-4/ACEA E5Total lube system capacity L (U.S. Gal) 6.0 (1.6)Oil pan capacity L (U.S. Gal) 4.5 (1.19)

Fuel SystemFuel Tank Capacity L (U.S. Gal) 45 (11.9)Generating set fuel consumption**

100% load L/hr (U.S. g/hr) 7.0 (1.9)75% load L/hr (U.S. g/hr) 5.6 (1.5)50% load L/hr (U.S. g/hr) 4.6 (1.2)

Engine Electrical System

Voltage/ground: 12 vDC/negativeBattery charging alternator ampere rating amps 55

Cooling SystemWater pump type: CentrifugalCooling system capacity L (U.S. Gal) 6.0 (1.8)Maximum coolant static head m H2O (ft H2O) TBACoolant flow rate L/hr (U.S. gal/hr) TBAMinimum temperature to engine °C (°F) TBATemperature rise across engine °C (°F) TBAHeat rejected to coolant at rated power kW (Btu/min) 23.9 (1360)Total heat radiated to room at rated power kW (Btu/min) 11.1 (631)Radiator fan load kW (hp) 1.2 (1.6)

Air RequirementsCombustion air flow m3 /min (cfm) 2.0 (70.6)Maximum air cleaner restriction kPa (in H2O) TBARadiator cooling air m3 /min (cfm) 69.0 (2437)Generator cooling air m3 /min (cfm) TBA

Exhaust SystemMaximum allowable backpressure kPa (in Hg) 10.2 (3.0)Exhaust flow at rated power m3 /min (cfm) 5.93 (209)Exhaust temperature at rated power

(dry exhaust) °C (°F) 575 (1067)

Generating Set Noise Rating*(without attenuation) at 1 m (3.28 ft) dBA TBA

Page 5: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 5/6

5 0 H z S T A N D B Y 1 7 . 5 k V A / 1 7 . 5 k W

Exclusively from your Caterpillar ®  dealer 

50 Hz

VoltageStandby

Code Voltage kVA kW

VOPT521 240 17.5 17.5

VOPT523 230 17.5 17.5

VOPT525 220 17.5 17.5

RATINGS AT AVAILABLE VOLTAGES

Ratings at 27° C (80° F), 152.4 m (500 ft), 60% humidity, unity pf

STANDBY

These ratings are applicable for supplying

continuous electrical power (at variable load) inthe event of a utility power failure. No overload

is permitted on these ratings. When used at

standby rating the alternator will be peak

continuous rated (as defined in ISO8528-3).

RATING DEFINITIONS

Page 6: Spec Sheet Geph17sp

8/3/2019 Spec Sheet Geph17sp

http://slidepdf.com/reader/full/spec-sheet-geph17sp 6/6

5 0 H z S T A N D B Y 1 7 . 5 k V A / 1 7 . 5 k W

Exclusively from your Caterpillar ®  dealer 

www.CAT-ElectricPower.com

278-397 © 2003 CaterpillarAll rights reserved.

European sourced Printed in U.S.A.

LEHF3051-00 (04/03) Materials and specifications are subject to change without notice.The International System of Units (SI) is used in this publication.