Speader Valves Hk66b102

12
Catalogue F uid uid Power d Power Fluid P wer Fluid Power Fu r Fluid Power Fluid Power Fluid Power Fluid Power Fluid d Power Fluid Power Fluid Power F ower Fluid Power Fluid Power Fluid wer Fluid Power Fluid Power Fluid P Fluid Power Fluid Power Fluid Powe id Power Fluid Power Fluid Power Power Fluid Power Fluid Power Fl r Fluid Power Fluid Power Fluid P Power Fluid Power Fluid Pow Fluid Power Fluid Power Fluid Power Fluid P wer Fluid Pow d Power Flu HK.66.B1.02 Spreader Valves Fluid Power

Transcript of Speader Valves Hk66b102

Page 1: Speader Valves Hk66b102

Catalogue

F uid

uid Power

d Power ■■■■ Fluid P

wer ■■■■ Fluid Power ■■■■ F u

r ■■■■ Fluid Power ■■■■ Fluid Power

Fluid Power ■■■■ Fluid Power ■■■■ Fluid

d Power ■■■■ Fluid Power ■■■■ Fluid Power ■■■■ F

ower ■■■■ Fluid Power ■■■■ Fluid Power ■■■■ Fluid

wer ■■■■ Fluid Power ■■■■ Fluid Power ■■■■ Fluid P

Fluid Power ■■■■ Fluid Power ■■■■ Fluid Powe

id Power ■■■■ Fluid Power ■■■■ Fluid Power ■■■■

Power ■■■■ Fluid Power ■■■■ Fluid Power ■■■■ Fl

r ■■■■ Fluid Power ■■■■ Fluid Power ■■■■ Fluid P

Power ■■■■ Fluid Power ■■■■ Fluid Pow

Fluid Power ■■■■ Fluid Power

Fluid Power ■■■■ Fluid P

wer ■■■■ Fluid Pow

d PowerFluHK.66.B1.02

Spreader Valves Fluid Power

Page 2: Speader Valves Hk66b102

HK.66.B1.02 Danfoss Fluid Power 10/93

Fluid Power

2

Introduction

Spreader Valves

GeneralFluid Controls is the worlds largest manufacturer of spreadercontrol valves, and has provided the market with a wide variety ofoptions. The primary use is ice and snow control for many city,county and township sand/salt spreader vehicles. Valves havealso been applied on many agricultural fertilizer spreadersystems, as well as construction paving equipment.

Fluid Controls Spreader valves can provide:• Single compact body permitting easy installation.• Manual or remote electrical control.• Load sensing capability.• Single or dual control.• Pressure compensation.• Gasket mounted configurations

Types and Operation

Type Description Symbol Models Page

Flow regulator, adjustable and pressurecompensated, with manual on/unload controland relief.

Single ManualControl Spreader 2FL12 3

Flow regulator, adjustable and pressurecompensated, with solenoid on/unload controlwith relief.

Single ControlSpreader withSolenoid Unload

2FLW86 4

Dual flow regulator, adjustable and pressurecompensated.

Dual ControlSpreader

2FF12 5

2FFC12 6Dual flow regulator, adjustable and pressurecompensated, with load sensing.

Dual Control LoadSensing Spreader

2FFLC12 7

Dual flow regulator, adjustable and pressurecompensated, with manual on/unload control andwith load sensing.

Dual ControlManual LoadSensing Spreader

Dual flow regulator, adjustable and pressurecompensated, with manual on/unload controland relief.

2FFL12 8Dual ControlManual Spreader

Dual flow regulator, adjustable and pressurecompensated, with solenoid on/unload controland relief.

Dual ControlSpreader withSolenoid Unlod

2FFLW86 9

Dual flow regulator, adjustable and pressurecompensated, with solenoid on/unload control, reliefand load sensing.

Dual ControlRemote LoadSensing Spreader

2FFCW12 10

Page 3: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 Danfoss Fluid Power 10/93 3

Single Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Relief

Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

Specifications• To 150 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.

Features• Honed and matched hardened steel

working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• On/unload lever control with detented

stops.• 100% performance tested.

Use and OperationFor use with fixed displacement pumpsin circuits that require a single pres-surecompensated flow control, manualon/ unload and pump relief. Ideal forspeed control of an actuator whichmust have a specific flow setting.Typical machinery applications include

agricultural equipment, salt and cinderspreaders and paving machinery.The valve maintains constant regulatedflow even with changes in loadpressure or input flow. The pressurecompensated regulating sectionbypasses excess pump flow to tank.The tank or bypass port must bereferenced directly to tank and not to aworking line. The direct acting reliefvalve senses system pressure andprotects the pump from shock oroverload pressure surges. The built-inlever operated two-way valve unloadssystem flow to tank. This allows on-unload control of regulated flow withoutchanging the flow setting. In the unloadcondition a 4,5 bar check valve may berequired in the »A« port, »T« port orboth to reduce the potential of motormovement.

Materials• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.

Performance curve

How to order

Adjust. MeansD = Detented

Hand Knob

Regulated Flow Range10 = 38 l/min15 = 57 l/min20 = 76 l/min30 = 115 l/min

Base Part No. Port Size6 = 3/4" NPTF

6W = G 3/4

2FL12 - D 6 - 20 SV

SealsSV = Viton A

P

T

A

Cartridge and Parts in Body 2FL12

Typical spreader circuit

●P

●T

A

≈ 206

108,0 1L10Cartride

≈ 106

63,5

Unload

On

121,2 ∅ 7,1

80,3

5,8

5,8

63,5

88,9

15,8

42,9

95,8

101,6

≈ 132

T

P

A

Regulated flow versushand knob detent positions

Page 4: Speader Valves Hk66b102

HK.66.B1.02 Danfoss Fluid Power 10/93

Fluid Power

4

Performance curve

How to order

Regulated flow versushand knob detent positions

Single Flow Regulator, Adjustable and Pressure Compensated,with Solenoid On/Unload Control and Relief

Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

Cartridges and Parts in Body 2FLW86

Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.

Features• Honed and matched hardened steel

working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• 100% performance tested.

Use and OperationFor use with fixed displacement pumpsin circuits that require a single pressurecompensated flow control, solenoidvalve for on-unload and pump relief.Ideal for speed control of an actuatorwhich must have a specific flow setting.Typical machinery applications includeagricultural equipment, salt and cinderspreaders and paving machinery.

The valve maintains constant regulatedflow even with changes in loadpressure or input flow. The pressurecompensated regulating sectionbypasses excess pump flow to tank.The pump operates at load pressureplus control section pressure drop. Thetank or bypass port must be referenceddirectly to tank and not to a workingline. The direct acting relief valvesenses system pressure and protectsthe pump from shock or overloadpressure surges. The built-in solenoidoperated two-way valve unloadssystem flow to tank. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »T«port or both ports to reduce thepotential of motor movement. Thisallows on/unload control of regulatedflow without changing the flow setting.

Materials• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.

Base Part No. Regulated Flow Range10 = 38 l/min15 = 57 l/min20 = 76 l/min30 = 115 l/min

Adjust. MeansD= Detented

Hand Knob

2FLW86 - D 6 - 20 SV

Port Size6 = 3/4" NPTF6W= G 3/4

SealsSV = Viton A

Typical spreader circuit

●T

REG

●P ●A

≈ 240

63,51L10Cartridge

7W20Solenoid

≈ 105

115,15,8

≈ 138

15,8

42,9

108,0

80,3

5,8

∅ 7,1

89,7

63,5

127,0

T

P

REG.

88,9

REG

P

T

A

Page 5: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 Danfoss Fluid Power 10/93 5

Performance curve

P T

A

S

Parts in Body 2FF12

Dual Flow Regulator, Adjustable and Pressure Compensated

Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

Typical spreader circuit

●P

●A

●S

●T

≈ 106

63,5

11,2127,0

≈ 149

121,2∅ 7,1

108,0

101,6

95,842,9

15,8

88,9

63,5

38,1

80,3

5,8

T

P

AS

Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.

Features• Honed and matched hardened steel

working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• 100% performance tested.

Use and OperationFor use with fixed displacement pumpsin meter in circuits that require two

pressure compensated flow controls.Ideal for use with a directional controlvalve that has a built-in system reliefand for speed control of two actuatorswhich must have individual flowsettings.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The tank or bypass port must bereferenced directly to tank and not to aworking line.

Materials• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.

Regulated flow versushand knob detent positions

How to order

2FF12 - D 6 - 5/15 SV

Adjust. MeansD= Detented

Hand Knob

Base Part No. SealsSV =Viton A

Regulated FlowRanges S (Spinner)5 = 0-19 l/min

10 = 0-38 l/min

Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min

Port Size6 = 3/4" NPTF6W = G 3/4

Page 6: Speader Valves Hk66b102

HK.66.B1.02 Danfoss Fluid Power 10/93

Fluid Power

6

≈ 106

63,5

12,7

12,7

5,8

≈ 145

127,0

115,1

88,9

63,5

30,0

∅ 7,1

≈ 117

108,0

69,3

38,1

89,7

L A

S

P

A

L

S

P

Dual Flow Regulator, Adjustable and Pressure Compensated, with Load Sensing

To 150 I/min and 210 bar

Typical spreader circuit

Specifications• To 210 bar.• Inlet flow to 150 l/min.• Regulated flow to 57 l/min.• Weight: 2,86 kg.

Features• Internal load sensing checks to

communicate pressure signals to loadsensing pump.

• Honed and matched hardened steelworking parts for long life.

• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• 100% performance tested.

Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require twopressure compensated flow controls.Ideal for use with solenoid controlleddirectional valves and for speed controlof two actuators which must haveindividual flow settings.This valve maintains constant regulatedflow to two actuators even with changesin load pressure. The »L« port sensesthe load pressure on both actuators andsignals the pump to increase ordecrease the supply flow.

MATERIALS• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.• Check component – Hardened

steel balls.• Seals – Viton A standard.

2FFC12 - D 6 - 7/15 SV

Regulated FlowRanges (Auger)15 = 0-57 l/min

Regulated FlowRanges (Spinner)5 = 0-19 l/min7 = 0-26,5 l/min

10 = 0-38 l/min

Port Size6 = 3/4" NPTF (P & A)

1/2" NPTF (S)1/4" NPTF (T)

Adjust MeansD= Detented

Hand Knob

Base Part No. SealsSV =Viton A

●P

Performance curve

Parts in Body 2FFC12

How to order

Regulated flow versushand knob detent positions

●A

●L

●S

Page 7: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 Danfoss Fluid Power 10/93 7

Performance curve

Parts in Body 2FFLC12

Dual Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Load Sensing

To 150 I/min and 210 bar

A

L

S

P

T

A

L

SP

T

Typical spreader circuit

6,4 76,2 12,7

25,4

88,9

∅ 7,1

6,481,0

111,0

49,322,1

52,319,1

A L

P

T

S

6,4

≈ 151

76,2

152,4

≈ 178

Specifications• To 210 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.

Features• Internal load sensing checks to

communicate pressure signals to loadsensing pump.

• Honed and matched hardened steelworking parts for long life.

• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• On/Unload lever control with detented

stops.• 100% performance tested.

Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require two

pressure compensated flow controls.Integral lever allows on/unload pumpcontrol. This valve is designed forspeed control of two actuators whichmust have individual flow settings.The valve maintains constant regulatedflow to two actuators even with changesin load pressure. The »L« port sensesthe load pressure on both actuators tosignal the pump to increase ordecrease the supply flow. With the leverin the unload position, no load issensed and the pump destrokes. In theunload condition a 4,6 bar check valvemay be required in either the »A« port,the »S« port or both ports to reduce thepotential of motor movement.

Materials• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.

Regulated flow versushand knob detent positions

2FFLC12 - D 6 - 10/30 SV

Base Part No. SealsSV =Viton A

Regulated FlowRanges S (Spinner)

5 = 0-19 l/min7 = 0-26,5 l/min

10 = 0-38 l/min

Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min

Port Size6 = 3/4" NPTF = Inlet and Auger (P & A)

1/2" NPTF = Spinner (A)1/4" NPTF = Tank Load Sense (T & L)

Adjust. MeansD= Detented

Hand Knob

How to order

Page 8: Speader Valves Hk66b102

HK.66.B1.02 Danfoss Fluid Power 10/93

Fluid Power

8

Performance curve

Cartridge and Parts in Body 2FFL12

Dual Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Relief

Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

P

A

T

S

A

T

S

P

Typical circuit

121,2 ∅ 7,11L10 Reliefcartridge

101,6

≈ 132

42,9

16,0

63,5

88,9

95,880,3

≈ 106

63,5

Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.

Features• Honed and matched hardened steel

working parts for long life.• Relief protection on main line.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Fully pressure compensated.• Gasket mounted models available.• On-unload lever control with detented

stops.• 100% performance tested.

Use and OperationFor use with fixed displacement pumpsin circuits that require two pressurecompensated flow controls, manualon-unload and pump relief. Ideal forspeed control of two actuators whichmust have individual flow settings.

Typical machinery applications includeagricultural equipment, salt and cinderspreaders and paving machinery.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The pump operates at the highestload pressure plus control sectionpressure drop. The tank or bypass portmust be referenced directly to tank andnot to a working line. The direct actingrelief valve senses system pressureand protects the pump from shock oroverload pressure surges. The built-inlever operated two-way valve unloadssystem flow to tank. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »S«port or both ports to reduce thepotential of motor movement. Thisallowson-unload control of both regulatedflows without changing either flowsetting.

How to order

Materials• Body – High-strength aluminium alloy.• Internal parts – Hardened steel.• Cartridge – Hardened steel.• Seals – Viton A standard.

Regulated flow versushand knob detent positions

Adjust. MeansD = Detented

Hand Knob

Port Size6 =3/4" NPTF

For Gasket Mtg.Consult Factory

Base Part No.

2FFL12 - D 6 - 10/30 SV

Regulated FlowRanges S (Spinner)

5 = 0-19 l/min7 = 0-26,5 l/min

10 = 0-38 l/min

Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min

SealsSV =Viton A

5,832,3

5,8

Page 9: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 Danfoss Fluid Power 10/93 9

Performance curve

TP

A

S

Cartridge and Parts in Body 2FFLW86

Dual Flow Regulator, Adjustable and Pressure Compensated,with Solenoid On/Unload Control and Relief

Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

Typical spreader circuit

A

T

S

P

127,0

88,9

63,5

15,8

42,9

38,1

∅ 7,1

80,3

108,0

≈ 138

11,9

5,8 115,1

90,0

T

P

S A

≈ 240 63,5

≈ 105

1L10 Cartridge

Specifications• To 140 bar.• Inlet flows to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.

Features• Honed and matched hardened steel

working parts for long life.• Relief protection on main line.• Adjustable and detented hand knob

with min. & max. stops. 11 positive,easy to adjust positions.

• Solenoid operated on/unload.• Fully pressure compensated.• 100% performance tested.

Use and OperationFor use with fixed displacement pumpsin circuits that require two pressurecompensated flow controls, solenoidvalve for on-unload and pump relief.Ideal for speed control of two actuatorswhich must have individual flowsettings. Typical machinery applications

include agricultural equipment, saltand cinder spreaders and pavingmachinery.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The pump operates at the highestload pressure plus control sectionpressure drop. The tank or bypass portmust be referenced directly to tank andnot to a working line. The direct actingrelief valve senses system pressureand protects the pump from shock oroverload pressure surges. The built-insolenoid operated two-way valveunloads system flow to tank. In theunload condition a 4,6 bar check valvemay be required in either the »A« port,the »S« port or both ports to reduce thepotential of motor movement.Thisallows on-unload control of bothregulated flows without changing eitherflow setting.

Materials• Body – High-strength aluminium alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.

How to order

Adjust. MeansD = Detented

Hand Knob

Base Part No. Port Size6 = 3/4" NPTF

Inlet, Tank andAuger (P, T & A);1/2" NPTFSpinner (S)

2FFLW86 - D 6 - 10/30 SV

Regulated FlowRanges S (Spinner)5 = 0-19 l/min7 = 0-26,5 l/min10 = 0-38 l/min

Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min

SealsSV =Viton A

Regulated flow versushand knob detent positions

Page 10: Speader Valves Hk66b102

HK.66.B1.02 Danfoss Fluid Power 10/93

Fluid Power

10

Performance curve

Cartridge and Parts in Body 2FFCW2

Dual Flow Regulator Pressure Compensated and Adjustable with Relief,Solenoid On/Unload and Load Sense

Max Inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar

1

2 3

9

60

11

4

5

10 8

7

1

2 3

9

60

11

4

5

10 8

7

Spinner

Auger

119,17,9

82,6

38,6

139,7108,0

38,1

9,4

12,7

25,463,5

84,1

103,1

63,5

127,0

111,0

23,6

≈ 197

≈ 102Detent adjust∅ 7,1

Thru 2-places

7W30-2-B12SVsolenoid cartridge

normally closed

Detentadjust

Specifications• Inlet to 150 l/min.• Regulated to 115 l/min.• Maximum inlet pressure: 140 bar.• Weight: 3,08 kg.

Features• Honed and hardened steel working

parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented with min.

& max. stops.• Pressure compensated.• IL10 differential area relief.• On-unload solenoid valve selector

(7W20).• 100% performance tested.

Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require two

pressure compensated flow (speed)controls. Electric solenoid allows on-unload pump control. This circuit isdesigned for speed control of twoactuators which must have individualflow settings.This valve maintains constant regulatedflow to two actuators even with changesin load pressure. The L port senses theload pressure on both actuators tosignal the pump to increase or reducethe supply flow. With the solenoid in theunload position, no load is sensed andthe pump destrokes. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »S«port or both ports to reduce thepotential of motor movement.

Materials• Body – High-strength aluminium

alloy.• Internal parts – Hardened steel.

How to order

2FFCW12 - D 6 - 10/30 SV

Regulated FlowRanges S (Spinner)

5 = 0-19 l/min7 = 0-26,5 l/min

10 = 0-38 l/min

Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min

Base Part No. Adjust. MeansD = Detented

Hand Knob

Port Size6 = 3/4" NPTF = Inlet and Auger (P & A)

1/2" NPTF = Spinner (A) 1/4" NPTF = Tank Load Sense (T & L)

SealsSV =Viton A

P

T

A

L

S

≈ 162

• Cartridge – Hardened steel.• Seals – Viton A standard.

Typical flow characteristics v.s. hand knobdetent positions for 5/15 randes

Page 11: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 Danfoss Fluid Power 10/93 11

CatalogueProducts

Ordering No.

Spreader Valves HK.66.B -.02

600 Series Valves HK.66.C -.02

400 Series Valves HK.66.D -.02

Relief Valves HK.66.F -.02

Sequence Valves HK.66.G-.02

Pressure Reducing Valves HK.66.H -.02

Motion Control Valves HK.66.I -.02

Unloading Valves and Pressure Intensifying Valves HK.66.J -.02

Needles and Restrictor Valves HK.66.K -.02

Flow Regulator Valves and Flow Divider Valves HK.66.L -.02

Pilot operated Check Valves HK.66.M-.02

Directional Control/Logic Valves HK.66.N -.02

Solenoid Directional Control Valves HK.66.O-.02

Fluid Controls Products

Product and catalogue survey

Page 12: Speader Valves Hk66b102

Fluid Power

HK.66.B1.02 © Danfoss Fluid Power 10/93

World Class Leadership in TechnologyDanfoss Fluid Power, a division of Danfoss, Inc., offers one of the world’slargest selections of quality fluid power components. An exceptional overalloffering of Danfoss, Dukes, Fluid Controls and Webster components allowsyou to choose the right products to meet your application. All of our units aremanufactured and tested to exacting engineering and quality control stan-dards to provide reliable long lasting performance.

Danfoss ProductsDanfoss products are known throughout the world for their quality, reliabilityand flexibility. From hydraulic motors, pumps, actuators and hydrostatic steer-ing components, to proportional hydraulics and electronics, Danfoss compo-nents redefine the leading edge.

Dukes ProductsThe Dukes name is recognized as the premier U.S. manufacturer of mobiledirectional control valves for applications to 115 l/min. Your specific needscan be addressed with mono-block or stack valves, or if required, a customdesigned valve.

Fluid Controls ProductsBeginning with the development of a compact, pilot-operated hydraulic reliefvalve over 40 years ago, Fluid Controls has remained a pioneer in hydraulicproduct miniaturization. Along with the wide variety of cartridge valves cur-rently available, Fluid Controls also features parts-in-body valves, andhydraulic integrated circuits to meet all of your requirements.

Webster ProductsSince 1945, Webster has been at the forefront in the development ofhydraulic gear pumps and cost effective multi-circuit components. Offering awide range of gear pumps and motors, Webster products can be found in amultitude of applications. The AC and DC power unit lines offer dependable,self-contained sources of hydraulic power. Flow dividers and rotary shearvalves further enhance the Webster line and expand the choices availablefrom Danfoss Fluid Power.

Danfoss A/S (SW-C) DTP 10.93 AO